RC-000078-2017 f. TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000078-2017 Date Issued: Tuesday, October 10, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000078-2017
has been completed.
Tax Map Number: 301.17-3-56
Location: 41 CAITLIN DR
Owner: Kelaco,LLC
Applicant: Collette Construction Inc.
This structure may be occupied as a: Single-Family Dwelling 3,082 s.f.,Garage
768 s.f By Order of Town Board
1 gas fireplace in family room TOWN OF QUEENSBURY
Subdivision: Pointe West,Lot 9
j 4 4k*--
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000078-2017
Tax Map No: 301.17-3-56
Permission is hereby granted to: Collette Construction Inc.
For property located at: 41 CAITLIN DR
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvoe of Construction
Owner Name: Kelaco,LLC Single Family-New $390,000.00
Owner Address: 35 Front ST Total Value $390,000.00
Lake George,NY 12845
Contractor or Builder's Name/Address Electrical Inspection Agency
Collette Construction Inc.
38 Collette LN
Hudson Falls,NY 12839
Plans&Specifications
Single-Family Dwelling 3,082 s.f,Garage 768 s.f
1 gas fireplace in family room
Subdivision: Pointe West,Lot 9
$1,631.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,March 15,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Quee before th pira on da
Dated at the To of Quee /,f e y,March 15,2017
SIGNED BY: y for the Town of Queensbury.
Director of Building&Code Enforcement
PRINf'IPAL STRUCTURE APPLICATION Office Use Only
Date: 4 ' '4E� ' I-) Permit No.
Tax Map ID 36 I. 17-3 Permit Fee 6•t,U+ /i .yd r 5a
Zone J � 1A Historic? _Yes _/No Ree Fee U" /'
Subdivision Name Pa tAmT L e3 T Lot# Site Plan#
�� Subdivision#
Project Location G&,ear Cl' W;-O- rsea v Liu')Q IbP"Ik
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This Is In addition to the
permit fee(s).
Primary Owner(s) / ^"''
KrNFS /ro
Address Q V
Phone/Email nn n
ti' n relJ t re># 17Pn.17TRLC1GV r)i n
Applicant
CC %It Cep. f�C�txTnw
AddressCOMMUNITY DEVELOPM NT
q fir//nom �' N�d' t• Fn// A),_V. ;g'^
Phone/Email
Contractor
I/t'/I`r Cay;,=f' Zig
Address 3F Ce/k fo L} N .
Phone/Email
Contact Person for Building&Codes Compliance: k"-A) Ca/Wlr Phone 3 6$ 5�1l
TYPE OF CONSTRUCTION
✓Check all that apply New Addition Alteration 1"floor sf 2ne floor sf Total sf Height
Single Family L j 13 c/ / g 30 33 f
Two-Family
Multi-Family
(#of units_)
Townhouse
Business Office
Retail-Mercantile
Factory-Industrial
Attached Garage
(1' 2'(�4+) 1
Other
Town of Queensbury Building&Codes Principal Structure Application revised January 2016
If commercial or industrial please indicate name of business
Proposed use of building or addition Sit, I- rfq„ v
Source of Heat(circle one) ra Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances &Chimneys
Are there structures not shown on plot plan?
Are there easements on the property? ;
Site Information:
a. Dimensions or acreage of lot j
b. Is this a corner lot? _Yes v No
c. Will the grade be changed as a result of construction Yes No
d. Public water or Private well(circle one) Public Private
e. Sewer or Private Septic System (circle one) _ 0 friva
Value of all work to be performed(labor or materials) $
DECLARATION:
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes,local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: DATE:
SIGNATURE: �� C� Z� 2t' DATE: a! 1
For office use only
Operating Permit Issued: _Yes —No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Fuel Burning Appliance & Chimne FeilDis n IV ice Use Only
ceived
DATE: MAR 0 2 2017 a Map ID
TAX MAP ID: Pe it No.
ZONE: ,i c Ii' TOWN OF QUEENSBU pp it Fee 5V o
COMMUNITY DEVELOPM Nf
OWNER IA<0 PHONE/E-MAILa7-
ADDRESS y).
S , tcr.
INSTALLER/ r PHONE/E-MAIL
BUILDER l f �/, � �• �P.�.�7` u.;C 3(i Sy��
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: ICr„ (•, I/�t%v �./
PHONE/E-MAIL S % 5 �-3 pp BUILDING ADDRESS i c art'k
ROOM OF INSTALL: f-AA-& PLANNED INSTALL DATE: /fey l `���" 7
FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN&
STOVE FINAL INSPECTION ARE
FIREPLACE INSERT REQUIRED.
FIREPLACE,FACTORY BUILT* I / NOTE:
MANUFACTURER'S
FIREPLACE,MASONRY
INSTALLATION MANUAL
FURNACE(GARAGE ONLY)
MUST BE AVAILABLE AT
TIME OF INSPECTION
*If factory built provide manufacturer name: i e r ;Model#: 3.: bV
Listed by: Number:
CHIMNEY INFORMATION
Masonry** (check one) BLOCK _BRICK _STONE
Flue _TIE _STEEL _Size in inches
Material _DOUBLE WALL _TRIPLE WALL _INSULATED
* If non-masonry provide manufacturer name: IL a ;Model#: L
DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or
manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances,
regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises
to perform required inspections.
I HAVE READ AND AGREE TO THE ABOVE:
PRINTNAME: Kea C,a lIP l� DATE:
SIGNATURE: K—,, CPVLL�,, DATE: 9,10 f l7
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
SEPTIC DISPOSAL APPLICATIETOWNOF
a Onl
Re d
DATE: 21 irs�l 20 Ta p ID
Pe
TAx MAP ID: N t F eZONE: EL
APPLICANT le7fP Ca/Ib? I/GG PHONE/E-MAIL (j5- 22
ADDRESS 3E C /P7/� Htarc/ rFlls N Y
INSTALLER/ ,.F 11 PHONE/E-MAIL
BUILDER CGA?tnP Ifty SfMf
OWNER cA�p
ADDRESS
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: Kp•J C"ile m,
PHONE/E-MAIL 3C5'-
RESIDENCE
CrRESIDENCE INFORMATION
Year Built #of bedrooms X gallons per bedroom =total Daily Flow
1980 or older Garbage grinder installed —Yes —No
1981-1991 Spa or Hot Tub installed Yes ✓No
1992-Present -
PARCEL INFORMATION
Topography Flat rolling _Steep slope _%Slope
Soil Nature Sand _Loam _Clay _Other
Groundwater At what depth: /Lt
Bedrock/Impervious material At what depth: _
Domestic Water Supply �/ Municipal _Well(if well,water supply from any septic system absorption is_ft.)
Percolation Test Rate: I - '3 per minute per inch(test to be completed by licensed engineer/architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION
Tank size (7=51'gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub
System Absorption field with#2 stone Total length 3 c Z ft.;Each Trench
Seepage Pit with#3 stone How many: _;Size
Alternative System Bed or other type:
Holding Tank System Total required capacity? Tank size #of tanks
Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will
no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the
septic system layout on file-no exceptions.
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure
to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to
abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
PRINT NAME: KP.J C,,/IP 17 DATE:
SIGNATURE: IC..,. r,Z4 DATE:
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Town of Queensbury Thomas R. Van Ness
Highway Department Highway Superintendent
742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929
Phone: 518-761-8211
Fax: 518-745-4466 David Duell
Deputy Highway Superintendent
Home: 518-745-0938
DRIVEWAY PERMIT
Date:
Applicant Name: Co l�A �,v 111,1C
Telephone No.:
Address to be Inspected
Return Address:
Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes
at the specified location
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action
has been taken:
STEP 1: ( ) Preliminary approval
NEED ( ) Slight Swale
( ) Deep Swale
( ) Level with the road
( ) Level with the top of the paved wing
Size culvert pipe to be used(if necessary)
( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36"
Preliminary inspection completed by: Date:
Approval by Highway Supt.: or Deputy Supt.:
Upon completion please resubmit this approval permit for a final approval.
STEP 2: ( ) Final Approval ( ) Rejected
Date:
Thomas R.Van Ness, Highway Superintendent David Duell,Deputy Highway Superintendent
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
VISION Engineering R -
9/15/17
Building and Codes Department
Town of Queensbury AS BUILI
742 Bay Road
Queensbury, NY 12804
RE: Collette Construction
41 Caitlin Drive— Lot 9 Onsite Sewage System
VISION Engineering, LLC previously designed the Pointe West Subdivision which included the
individual household onsite wastewater disposal system (septic system) for the above location. This
letter shall serve as certification that, upon information obtained from inspections and/or the Contractor,
portions of work designed by our office appear to have been installed in general conformance with
approved plans and specifications.
Thank you and please do not hesitate to contact me if you have any questions or require additional
information.
Sincerely,
Daniel W.Ryan P.E.
2017.09.15 07:18:04-04'00' Crj� P�y�E fl�
�
Daniel W. Ryan, P.E.
VISION Engineering, LLC cc
07906
g0�ES S 1 ONP�
206 Glen Street•Suite 56•Glens Falls, NY•12801 •P: 518-792-9264
www.visionengineeringlic.com
jolt? ERS --2
j1 i4 iq
n ifl o�j
i
-rA 4k
Rax
L e Aj/, L itur,'
[CP
OF
Lf cm ILE I A)
V
SEPTIC PLOT PLAN
I HAVE SEEN OR OBSERVED ALL OBJECTS
SUCH AS HOUSES, WELLS,TREES, FENCES, ETC
SiGNATu E U ET I I HAVE PERSONALLY
SET FORTH ON THIS DI RA .
WN THIS � L
MEASU THEIST N '
AT
, 90
D EC � o � �
0 ���- J MAR D
/ 17
wA7eR '� GA2�y�P I �•�— COMMUNIITyQUE 0 2 20/ SSURY 1—e ELOPINENT
l si
�< `.� Opti `•, �._,--
`ti.
DK
""gyp ..
11oWlVe( , '- aAlld .. res S
r (at Anti {n (� ItFE poi �rs1 nq�(s. a� 301.17-3-56 RC 78-2017
r� ,ti Y Collette Construction Inc.
Lot 9, House No. 41 Caitlin Drive
3. 1 N l SFD w/ att. garage, 1-gas fp
Manual S Compliance Report Job: SEEBER
Date: Mar 06,2017
Entire House By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY, NY 12804
Project • •
For: SEEBER
QUEENSBURY, NY 12804
Cooling
Design Conditions
Outdoor design DB: 85.0°F Sensible gain: 23935 Btuh Entering coil DB: 75.5'F
Outdoor design WB: 71.0°F Latent gain: 3313 Btuh Entering coil WB: 63.0'F
Indoor design DB: 75.0°F Total gain: 27248 Btuh
Indoor RK 50% Estimated airflow: 1080 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split AC
Manufacturer: York Model: YCE36B21+H,YG32(1,2)36++MX12DN21
Actual airflow: 1080 cfm
Sensible capacity: 0 Btuh 0% of load
Latent capacity: 0 Btuh 0% of load
Total capacity: 0 Btuh 0% of load SHR: 0%
Heating Equipment
Design Conditions
Outdoor design DB: -4.0'F Heat loss: 76596 Btuh Entering coil DB: 66.4'F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Gas furnace
Manufacturer: York Model: TM9M080B12MP12
Actual airflow: 1080 Cfm
Output capacity: 77000 Btuh 101% of load Temp. rise: 50 OF
Meets are all requirements of ACCA Manual S.
2017-Mar-06 10:36:42
wrightSOW Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
)CCA ...ers\scott.langewonhy\Documents\York\SEEBER.rup Calc=MJ8 Front Door faces: N ,' r
C6)/v S
Residential — Review • Form
• D— •n (Loads, Equipment, Ducts) 15 Mar 09
4c. raibatbsdNiwl®
QUEENSBURY NY 12804
Header Information
Contractor: CERRONE P&H REQUIRED ATTACHMENTS ATTACHED
Manual J1 Form(and supporting worksheets): Yes No
Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes No tJ
OEM performance data(heating,cooling,blower): Yes ❑ No tl
Building plan* 1226 Manual D Friction Rate Worksheet: Yes [-] No ❑
Duct distribution sketch: Yes 0 No 0
Home address(Street or Lot#,Block,Subdivision): , Entire House
HVAC • . ■ CALCULATION •
Design Conditions Building Construction Information
Winter Design Conditions Building
Outdoor temperature: -4 °F Orientation: Front Door faces North
Indoor temperature: 70 eF Nodh,Fast,West,South,Northeast,Northwest,southeast,southwest
Total heat loss: 76596 Btuh Number of bedrooms: 0
Conditioned floor area: 4347 f 2
Summer Design Conditions Number of occupants: 0
Outdoor temperature: 85 °F
Indoor temperature: 75 °F Windows Roof
Grains difference: 28 gr/Ib @50% RH Eave overhang depth: 0 R
Sensible heat gain: 26595 Stith Internal shade: none
Latent heat gain: 3681 Stith Blinds,drapes,etc. Depth Window
Total heal gain: 30276 Btuh Number of skylights: 0
HVAC EQUIPMENT • •
Heating Equipment Data Cooling Equipment Data Blower Data
Equipment type: Gas furnace EVigment type: SplitAC Heating cfm: 1080
umace,Ne pump,Boller,etc. it ondttloner,Heat pump,etc. Cooling cfm: 1080
Model: York Model: York Static pressure: 0 in H2O
TM9M080B12MP12 YCE36821 Fan's rated eatemal static pressure for
Heating output capacity: 77uPtlp0 Bluh Total cooling capacity: 0 Btuh design ahfbw
Heat pumps-capacity at winterdeslgn o oorcontlttbns
Sensible cooling capacity: 0 Btuh
Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh
HVAC DUCT DISTRIBUTION SYSTEM ■ 6
Design airflow: 1080 cfm Longest supply duct: 0 It Duct Materials Used
Equipment design ESP: 0 in H2O Longest return duct: 0 It Trunk duct:
Total device pressure losses: 0 in H2O Total effective length(TEL): 0 It
Available static pressure(ASP): 0 in H2O FrictionFdctian rate:Rate=ASp♦(TELa idb)(1 in/100ft Branch duct: Sheet metal
declare the load calculation,equipment, -q • selection- s • . design rigorously performed based • - building
a -• above. s- • .a- • - be subject • verification.
Contractor's printed name:
Contractor's signature: Date:
Reserved for County,Town Municipality orAuthority having jurisdiction use.
'Home qualifies for MJtAE Form based on Abridged Edition Checklist
'I' WrIghtSOft' Right-Suite®universal 2017 17.0.leRSU25116
Project Summa Job: SEEKER
Date: Mar 06,2017
Entire House By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY,NY 12804
Promect Information
For: SEEBER
QUEENSBURY, NY 12804
Notes:
Design • •
Weather: Glens Falls AP, NY, US
Winter Design Conditions Summer Design Conditions
Outside db -4 'F Outside db 85 OF
Inside db 70 'F Inside db 75 OF
Design TO 74 'F Design TD 10 OF
Daily range M
Relative humidity 50 %
Moisture difference 28 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 70448 Btuh Structure 22799 Btuh
Ducts 6148 Btuh Ducts 1136 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 76596 Btuh Use manufacturer's data n
Rate/swing multiplier 0.90
Infiltration Equipment sensible load 21542 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1340 Btuh
Ducts 1973 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft') 4347 4347 Equipment latent load 3313 Btuh
Volume ft') 22803 22803
Air changes/hour 0.42 0.19 Equipment total load 24855 Btuh
Equiv.AVF(cfm) 161 72 Req. total capacity at 0.70 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make York Make York
Trade YORK Trade ADP
Model TM9M080B12MP12 Cond YCE36B21
AHRI ref 3861629 Coil H,YG32(1,2)36++MX12DN21
AHRI ref 8739209
Efficiency 97AFUE Efficiency 12.2 EER, 14 SEER
Heating Input 80000 Btuh Sensible cooling 22680 Btuh
Heating output 77000 Btuh Latent cooling 9720 Btuh
Temperature rise 66 OF Total cooling 32400 Btuh
Actual air flow 1080 cfm Actual air flow 1080 cfm
Air flow factor 0.014 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
C Wrl I7t50ft' 2017-Mar-0610:36:42
9 Right-Suee®universal 201717.0.16 RSU25116 Page 1
...emXscott.langmorthy\Documents\York\SEEBER.rup Calc=MJ8 Front Door faces: N
AED Assessment Job: SEEKER
Date: Mar 06,2017
Entire House By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY, NY 12804
Project •
For: SEEBER
QUEENSBURY, NY 12804
Design Conditions
Location: Indoor: Heating Cooling
Glens Falls AID, NY, US Indoor temperature (°F) 70 75
Elevation: 335 ft Design TD (°F) 74 10
Latitude: 430N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.8 27.6
Dry bulb (°F) -4 85 Infiltration:
Daily range (°F) - 20 ( M )
Wet bulb (°F) - 71
Wind speed (mph) 15.0 7.5
Test for • • Exposure
Hourly Glazing Load
22,000-
20,000--
18,000--
16,000--
14,000--
12,000-
x,
2,00020,00018,00016,00014,00012,000
10,000--
8,000--
6,000--
4,000--
2,000-
0
0,0008,0006,0004,0002,0000
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
/Haurr/ /A-r,. /AEDfint
Maximum hourly glazing load exceeds average by 20.3°/x.
House has adequate exposure diversity (AED), based on AED limit of 30°/x.
AED excursion: 0 Btuh
Wrl htsOf '
2017-Mar-06 10:a36 ge 1
g Right-SuiteO�Universal RSU26116 Page 1
ACC. ...ers\scotl.langeworthy\Documents\York\SEESER.rup Calc=MJ8 Front Door faces: N
Right-J® Worksheet Job: SEEKER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY,NY 12804
1 Room name Entire House Roornl
3 Rxposed' tall 566.0 0 184.0 ft
4 Room height is 9.0 ft d 9.0 ft heaNcod
1.0 x 1398.0 it
5 Room area 4347.0 ft' 1398.0 ft'
Ty Construction U-value Or HTM Area (112) Load Area (ftT) Load
number (BtuNftk'F) (Btuh/ft� a perimeter (ft) (Stub) a perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gmss N/P/S Heat Cod
6 12C-0sw 0.091 n 6.73 1.50 486 446 3003 670 0 0 0 0
1Dc.2ov 0.570 n 4218 16.36 40 0 1687 654 0 0 0 0
15B-8s3c6 0.100 n 5.88 0.16 1017 882 5172 143 522 501 3012 107
113c2ov 0.570 n 4218 16.36 72 0 3037 1176 0 0 0 0
11 11DO 0.390 n 28.88 8.38 42 42 1212 352 0 0 0 0
11P0 0.290 n 21.46 6.23 21 21 451 131 21 21 451 131
T-0
12C-0sw 0.091 a 6.73 1.50 432 392 2540 589 0 0 0 0
T-G 1D-c2w 0.570 a 4218 58.17 40 0 1687 2327 0 0 0 0
ltU 15B-853c8 0.100 a 5.92 0.18 612 552 3270 101 306 282 1679 55
---C 1Dc2w 0.570 a 4218 58.17 60 0 2531 3490 24 0 1012 1396
12C-0sw 0.091 s 6.73 1.50 486 398 2680 598 0 0 0 0
113c2ov 0.570 s 4218 30.57 88 0 3712 2690 0 0 0 0
1Q/ 15B-8s3c-6 0.100 5 5.97 0.21 1017 946 5646 197 522 522 3167 122
CLCD, 1Dc2ov 0.570 s 4218 30.57 36 0 1518 1101 0 0 0 0
11DO 0.390 s 28.86 8.38 35 35 1010 293 0 0 0 0
1R1 12C-0sw 0.091 w 6.73 1.50 432 396 2667 595 0 0 0 0
--G 1Dc20v 0.570 w 4218 58.17 36 0 1518 2094 0 0 0 0
15B-85368 0.100 w 5.95 0.20 612 567 3381 111 306 306 1857 71
1Dc2o'v 0.570 w 4218 58.17 24 0 1012 1396 0 0 0 0
11DO 0.390 w 28.66 8.38 21 21 606 176 0 0 0 0
C 168-30ad 0.032 - 237 1.44 1595 1595 3777 2297 0 0 0 0
C 16B-30ad 0.032 - 237 1.44 426 426 1009 613 96 96 227 138
F 19A-19bscp 0.049 - 284 0.38 671 571 1623 219 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 1398 1398 2586 0 1398 1398 2588 0
F 21A-24t 0.025 - 1.85 0.00 52 52 96 0 0 0 0 0
6 c)AED excursion 0 38
Envelope loss/gain 57531 22015 13992 2058
12 a) Infiltration 12917 785 2440 148
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Applianoes/other 0 0
Subtotal(lines 6 to 13) 70448 22799 16432 2206
Less external load 0 0 0 0
Less transfer 0 0 0 o
Redistribution 0 0 0 0
14 Subtotal 70448 22799 16432 2206
ds
15 Duct loa9%1 5% 6148 1136 9% 5%1 1434 110
Total room load 76596 23935 17868 2318
Air recluved(cfm) 1080 1080 252 105
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c 4F wrf htsoft- 2017-Mar-0610:36:42
9 Right-Soils®Universal Fron16 page 1
...errs\scoll.langewonhy\Dowments\York\SEEBER.rup Calc-M.18 Front Door faces: N
Right-J®Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY.NY 12804
1 Room reme Roorn2 Room3
2 Exposed wall 520 ft 320 ft
3 Room height 9.0 it heat/0001 9.0 ft heaticod
4 Room dmensions 18.0 x 16.0 it 1.0 x 372.0 it
5 Room area 288.0 ft' 372.0 ft'
Ty I Construction U-value Or HTM Area (ftp LOW Arm (ftp Load
number (BtutVftk'F) (Btuhtft� or perimeter (ft) (Btuh) a pedmeter (ft) (Btuh)
Hyl Cod Gross NIP/S Heat cod Gross N/P/S Heat Cod
6 14,r 12C-0sw 0.091 n 6.73 1.50 0 0 0 0 0 0 0 0
�G 1Dt2ov 0.670 n 4218 16.36 0 0 0 0 0 0 0 0
V 15B-8s3c-6 0.100 n 5.86 0.16 162 126 717 13 225 171 966 15
�L�GDp 1D-c2ov 0.570 n 42.18 18.36 36 0 1518 589 12 0 506 196
11 11DO 0.390 n 28.88 8.38 0 0 0 0 42 42 1212 352
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
1Rl 12C-Osw 0.091 a 6.73 1.50 0 0 0 0 0 0 0 0
T-6 1Dc20v 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
W 15B-8s3c-6 0.100 a 5.92 0.18 0 0 0 0 18 18 109 4
T-G 1Dc2ov 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
ltU 12C-0sw 0.091 5 6.73 1.50 0 0 0 0 0 0 0 0
-0 1Dc2cv 0.570 s 4218 30.57 0 0 0 0 0 0 0 0
15B-8s3c-6 0.100 5 5.97 0.21 162 162 983 3B 45 45 273 10
1 D-c2ov 0.570 s 42.18 30.57 0 0 0 0 0 0 0 0
11DO 0.390 s 28.86 8.38 0 0 0 0 0 0 0 0
l41 12C-0sw 0.091 w 6.73 1.50 0 0 0 0 0 0 0 0
T-G 1Dc2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
15B-853c-6 0.100 w 5.96 0.20 144 120 696 17 0 0 0 0
tl 1Dc2ov 0.570 w 42.18 58.17 24 0 1012 1396 0 0 0 0
11DO 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 16B60ad 0.032 - 237 1.44 0 0 0 0 0 0 0 0
C 168-30ad 0.032 - 237 1.44 180 180 425 259 96 96 227 138
F 19A-19bscp 0,049 - 2.84 0.38 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-2411 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AEDexcursion 387 66
Envelope loss/gain 5353 2699 3294 650
12 a) Infiltration 690 42 424 26
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines a to 13) 6042 2741 3718 676
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redstdbution 0 0 0 0
14 Subtotal 6042 2741 3718 676
15 Dud loads 9% 5% 527 137 9% 5% 324 34
TMa]room load 6570 2877 4042 709
Air required(cfm) 93 130 57 32
_ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� '1* wrilghtsaoTY- 2017-Mar-0610:36:42
. P. Right-Saha®Universal201717.0.16ron16
...ars\scott.lengewodhy\Documents\York\$EEBER.ND Cek=MJ8 Front Door feces: N Paget
Right-J® Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
CERRONE P&H Plan. S ZOTT
QUEENSBURY,NY 12804
1 Room name Room4 Room5
2 Exposed wall 26.0 ft 26.0 ft
3 Room height 9.0 ft heat/cod 9.0 ft hwUcool
4 Room dmensions 12.0 x 14.0 it 120 x 16.0 ft
5 Room ansa 168.0 ft' 1920 ft'
Ty Construction U-value Or HTM Arm (ft') Load Area (ft-) Load
number (BlutVfti°F) (BtLdvftl a perimeter (ft) (Btuh) or perimeter (ft) (Bluh)
HeatCod Grcas N/P/S Heat Cod Gross N/P/S Heat Cod
6 14/ 12C-0sw 0.091 n 6.73 1.50 0 0 0 0 0 0 0 0
�G 1Dc2w 0.570 n 4218 16.36 0 0 0 0 0 0 0 0
15B-8s3c� 0.100 n 5.86 0.16 108 84 478 8 0 0 0 0
1Dc2ov 0.570 n 4218 16.36 24 0 1012 393 0 0 0 0
11 11DO 0.390 n 28.86 8.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
4U 12C-Osw 0.091 a 6.73 1.50 0 0 0 0 0 0 0 0
-0 1Dc2ov 0.670 a 4218 58.17 0 0 0 0 0 0 0 0
4y 15B-8s3G6 0.100 a 5.92 0.18 126 114 676 21 144 120 696 17
T-C 1Dc2ov 0.570 a 4218 58.17 12 0 506 698 24 0 1012 1396
12C-05w 0.091 s 6.73 1.50 0 0 0 0 0 0 0 0
1Dc2ov 0.570 s 4218 30.57 0 0 0 0 0 0 0 0
lM 15B-853c-6 0.100 5 5.97 0.21 0 0 0 0 108 84 478 8
t�-GD 1Dc2av 0.570 5 4218 30.57 0 0 0 0 24 0 1012 734
11DO 0.390 5 28.86 8.38 0 0 0 0 0 0 0 0
Y---G
12C-0sw 0.091 w 6.73 1.50 0 0 0 0 0 0 0 0
---C 1D-c2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
1513-15SX-6 0.100 w 5.96 0.20 0 0 0 0 0 0 0 0
lD-c2cv 0.570 w 42.18 58.17 0 0 0 0 0 0 0 0
11DO 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 1613-00ad 0.032 - 2.37 1.44 0 0 0 0 0 0 0 0
C 166-30ad 0.032 - 2.37 1.44 36 36 85 52 16 16 38 23
F 194-19bscp 0.049 - 264 0.38 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AED excursion -106 -196
Envelope loss/gain 2757 1065 1 3236 1982
12 a) Infiltration 345 21 371 23
b) Room ventilation 0 0 0 0
13 lmenA gains: Occupants 230 0 0 0 0
Appliances/other 1 0 0
Subtotal(lines 6 to 13) 3102 1086 3608 2004
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3102 1086 3608 2004
15 Dud loads 9% 5% 271 54 9% 5% 315 100
Total room load 3373 11413923 2104
Air required(cfm) 48 51
551 95
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c wri hT50f[' Ri2017-Mar-0610:3642
9 ght-Sulte®Universal 2017 17.0.16 RSU25116 Page 3
...ens\scdt.langewonhy\Documents\York\SEEBER.mp Calc=MJ8 Front Doafaces: N
Right-J®Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
CERRONE P&H Plan:
SCOTT
Plan: SCO
1226
QUEENSBURY,NY 12804
1 Room name Roon16 Room7
2 Exposed wall 11.0 It 220 it
3 Room height 9.0 It heat/COOI 9.0 It heaVcool
4 Room dimensions 7.0 x 18.0 ft 1.0 x 113.0 It
5 Room arm 128.0 ft2 113.0 112
Ty Construction U-vaWe Or HTM Area (ft2) Load Arm (ft-) Load
number (BtutVft-F) (BtuWft2) or perimeter (ft) (Stub) or Perimeter (ft) (Btuh)
HeatCod Gross NIP/S Heat Cad Gross N/P/S Heat Cod
8 l4/ 12C-0sw 0.091 n 6.73 1.50 0 0 0 0 0 0 0 0
-G 1Dc2ov 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
15B-8s3c-6 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1Dc2ov 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
11 11D0 0.390 n 28.86 8.36 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
141 12C-0sw 0.091 a 6.73 1.50 0 0 0 0 0 0 0 0
T-G 1Dc2✓ 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
l4/ 158-853c-6 0.100 a 5.92 0.18 18 18 109 4 0 0 0 0
I-C 1Dc2w 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
V)/ 12C-Osw 0.091 s 6.73 1.50 0 0 0 0 0 0 0 0
� a 113c2ov 0.570 5 42.18 30.67 0 0 0 0 0 0 0 0
IN 15B-883c-8 0.100 s 5.97 0.21 63 28 123 0 117 105 621 19
�� 1Dc2ov 0.570 s 42.18 30.57 0 0 0 0 12 0 508 387
11D0 0.390 s 28.86 8.38 35 35 1010 293 0 0 0 0
T-0
12C-0sw 0.091 w 6.73 1.50 0 0 0 0 0 0 0 0
T-C 1Dc2av 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
l4! 15B-8s3c6 0.100 w 5.96 0.20 18 18 109 4 81 81 492 19
CLCD 1Dc2w 0.570 w 42.18 58.17 0 0 0 0 0 0 0 0
11D0 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 16830ad 0.032 - 237 1.44 0 0 0 0 0 0 0 0
C 16830ad 0.032 - 2.37 1.44 2 2 5 3 0 0 0 0
F 184-19bscp 0.049 - 284 0.38 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 4 4 7 0 27 27 50 0
8 c)AED excursion -28 69
Envelope loss gain 1364 277 1669 474
12 a) Infiltration 146 9 292 18
b) Roan ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1510 286 1961 492
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1510 2W 1961 492
15 Duct loads 9% 5% 132 14 9% 5% 171 24
Total room load 1642 300 2132 518
Air regdred(cfm) 23 14 30 23
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
. h � wrightsafY 2017-Mar-0610:36:42
Right-Surk\SEEversal201717.0.188 Front
Page
...ars\scott.langaworthy\Documents\York\SEEBER.rup Calc=MJB Front Door/aces: N
Right-J®Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
CERRONE P&H Plan: 122677
DUEENSBURY.NY 12804
1 Room name Rooms Room9
2 Exposed wall 0 It 7.0 ft
3 Room height 9.0 ft heat/ccol 9.0 ft hwUcod
4 Room dimensions 4.0 x 8.0 It 9.0 x 7.0 ft
5 Room area 32.0 112 63.0 ft,
Ty Construction U-value Or HTM Area (112) Load Area (ft2) Load
number (BtutvfV--°F) (Btutvft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
HeatCod Gross N/P/s Heat Cod Gross N/P/S Heat Cod
8 %f--G
12C-0sw 0.091 n 6.73 1.50 0 0 0 0 0 0 0 0
�G 1Dc2w 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
15B-8s3c-6 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1DC2ov 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
11 11DO 0.390 n 28.86 8.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
l4! 12C-0sw 0.091 a 6.73 1.50 0 0 0 0 0 0 0 a
T-G 1DC2cv 0.570 8 42.18 58.17 0 0 0 0 0 0 0 0
VN 15B-853C-60.100 a 5.92 0.18 0 0 0 0 0 0 0 0
T-G 1DC2ov 0.570 a 42.18 58.17 0 0 0 0 0 0 0 a
15U 12C-0sw 0.091 S 6.73 1.50 0 0 0 0 0 0 0 0
Y-C 1Dc2ov 0.570 s 4z 18 30.67 a 0 0 0 a 0 0 0
1(v 15B-8s3c6 0.100 s 5.97 0.21 a 0 0 0 0 a 0 0
�-G 1DC2ov 0.570 5 42.18 30.57 0 0 0 0 0 0 0 0
11DO 0.390 s 28.86 8.38 0 0 0 0 0 0 0 0
tP/ 12C-0sw 0.081 w 8.73 1.50 0 0 0 0 0 0 0 0
�--G 1Dc2w 0.670 w 42.18 58.17 0 0 0 0 0 0 0 0
l4/ 15B-Bs3c-6 0.100 w 5.96 0.20 0 0 0 0 63 42 227 0
1DC2ov 0.670 w 42.18 58.17 0 0 0 0 0 0 0 0
11D0 0.390 w 28.86 8.38 0 0 0 0 21 21 606 176
C 16BJ0ad 0.032 - 2.37 1.44 0 0 0 0 0 0 0 0
C 16630ad 0.032 - 2.37 1.44 0 0 0 0 0 0 0 0
F 19.4-tgbscp 0.049 - 2.84 0.38 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 21 21 39 0
6 0)AED excursion 0 -16
Envelope loss/gain 0 0 872 160
12 a) Infiltration 0 0 93 6
b) Roan ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 0 0 965 1s6
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 0 0 965 166
15 Duct loads 9% 5% 0 0 9% 5% 84 8
Total room load 0 0 1049 174
Air required(cfm) 0 0 1 15 8
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c w1Y htSOft' 2017-Mar-0610:36:42
. A 9 Right-Sulte®Universal 2017 17.0.16 RSU25116 Page 5
...ars\scott.lange arthy\Documents\York\SEEBER.mp Calc=MJ8 Front Door faces: N
Right-J®Worksheet Job: SEEKER
Entire House Date: Mar 06,2017
CERRONE P&H Fran: 1226TT
QUEENSBURY,NY 12804
1 Room name Roan12 Room13
2 Exposed wall 920 ft 5.0 ft
3 Room height 9.0 It heaucool 9.0 It heat/cool
4 Rcom dimensions 1.0 x 575.0 ft 5.0 x 6.0 ft
5 Room area 575.0 ft2 30.0 ft'
Ty Construction U-value Or HTM Arm (ftp Load Area (ftp Load
number (BtuNft-'F) (Btulyft') a pedmeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 1#r 12C-0sw 0.091 n 6.73 1.50 153 153 1030 230 45 45 303 68
�-C 1Dc20v 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
15B-8s3c8 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1Dc2ov 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
11 1100 0.390 n 28.86 8.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
T-G12C-0sw 0.091 a 6.73 1.60 162 162 1091 243 0 0 0 0
iDc2ov 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
15B-8s3c6 0.100 a 5.92 0.18 0 0 0 0 0 0 0 0
1Dc2ov 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
12C-0sw 0.091 s 6.73 1.50 153 129 889 194 0 0 0 0
1Dc2ov 0.570 s 42.18 30.57 24 0 1012 734 0 0 0 0
W� 15B-8s3c6 0.100 s 5.97 0.21 0 0 0 0 0 0 0 0
1Dc20v 0.570 S 42.18 30.67 0 0 0 0 0 0 0 0
1100 0.390 s 28.86 8.38 0 0 0 0 0 0 0 0
l4/ 12C-0sw 0.091 w 6.73 1.50 360 324 2182 486 0 0 0 0
T-C 1Dc2av 0.570 w 4218 58.17 36 0 1518 2094 0 0 0 0
l¢/ 15B-8s3c6 0.100 w 5.96 0.20 0 0 0 0 0 0 0 0
I�-CD 1Dc2ov 0.570 w 42.18 58.17 0 0 0 0 0 0 0 0
11DO 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 166-30ad 0.032 - 2.37 1.44 675 575 1362 828 30 30 71 43
C 16B-30ad 0.032 - 2.37 1.44 0 0 0 0 0 0 0 0
F 19A-19bscp 0.049 - 2.84 0.38 473 473 1344 182 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AED excursion 301 -11
Envelope loss/gain 10408 5291 374 100
12 a) Infihration 3660 222 199 12
b) Room ventilation 1 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 14058 5513 573 112
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 14068 5513 573 112
151 Duct loads 9% 5% 1228 275 9% 5% 50 6
Total room load 15296 5788 623 117
Air required(cfm) 216 261 9 5
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrilht5oft' 2017-Mer-0610:36:42
9 Right-Babe®Universal201717.0.168 Fron16 Page6
...ers\scott.langeworthy\Documents\York\$EEBER.Np Calc=MJB Frant Door faces: N
Right-J® Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY, NY 12804
1 Room name Roan14 Room15
2 Exposed wall 11.0 it 11.0 ft
3 Room height 9.0 ft hee1000l 9.0 ft heat/cod
4 Room dimensions 5.0 x 12.0 ft 1.0 x 118.0 ft
5 Room area 60.0 ft' 118.0 ft'
Ty Construction U-value Or HTM Area (ftp Load Am (ftj Load
number (Bti7Vftx°F) (BtuWft2) a Perimeter (ft) (Btuh) or perimeter (ft) (Bluh)
HeatCod Gross N/P/S Heat Cod Gross N/P/S Heat cod
e W/ 12C-0sw 0.091 n 6.73 1.60 45 33 222 50 99 83 559 125
--C 1Dc2ov 0.570 n 4218 18.36 12 0 506 196 16 0 675 262
15B-8s3a6 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1Dc2ov 0.670 n 42.18 16.36 0 0 0 0 0 0 0 0
11 11DO 0.390 n 28.86 8.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
W 12C-0sw 0.091 a 6.73 1.50 0 0 0 0 0 0 0 0
---G 1Dc2w 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
W 15B-8s3c6 0.100 a 5.92 0.18 0 0 0 0 0 0 0 0
t-G 11)c2ov 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
Utl 12C-0sw 0.091 s 6.73 1.50 0 0 0 0 0 0 0 0
T-G 1DQ0v 0.570 s 4218 30.67 0 0 0 0 0 0 0 0
15B-8s3c-6 0.100 s 5.97 0.21 0 0 0 0 0 0 0 0
1Dc2ov 0.570 5 42.18 30.67 0 0 0 0 0 0 0 0
1100 0.390 5 28.86 8.36 0 0 0 0 0 0 0 0
t12C-0sw 0.091 w 6.73 1.50 54 54 364 81 0 0 0 0
-6 1Dc20v 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
1W 15B-8s3a6 0.100 w 6.96 0.20 0 0 0 0 0 0 0 0
��fD 1Dc2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
1100 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 237 1.44 60 60 142 66 118 118 279 170
C 168-30ad 0.032 - 237 1.44 0 0 0 0 0 0 0 0
F 19A-19bscp 0.049 - 284 0.38 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AED excursion -39 52
Envelope loss/gain 1234 374 1513 504
12 a) Infiltration 438 27 438 27
b) Roan ventilation 0 0 0 0
13 Internal gains: Occupants 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1672 401 1951 531
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1672 401 1951 531
15 Duct loads W. 5% 146 20 9% 5% 170 28
Total mom Iced 1818 421 2121 557
Air required(cfm) 26 19 30 25
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c wri ht901ft' 2017-Mer-0610:36:42
A 9 Right-SulteO Universal 2017 17.0.16 RSU25116 Page 7
...em\scott.langeworthy\DocumentslYork\SEEBER.mp Calc=MJB Front Doorfaces: N
Right-J® Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY,NY 12804
1 Roam name Room16 Room17
2 Exposed wall 5.0 ft 21.0 it
3 Roam height 9.0 ft heat/cod 9.0 it heat/cool
4 Room dimensions 5.0 x 10.0 it 11.0 x 10.0 it
5 Room area 50.0 ft' 110.0 ft'
Ty Constmction U-value Or HTM Area (ft) Load Ariz (ftp Load
number (BtuWWF) (Btuh/ft� a perimeter (ft) (Stuh) a perimeter (ft) (Btuh)
Heat Cad Gross N/P/S Heat Cool Gross N/P/S Heat Cod
812C-0sw 0.091 n 6.73 1.50 45 45 303 68 99 87 588 131
1Dc2ov 0.570 n 4218 16.36 0 0 0 0 12 0 508 196
15B-893c-6 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1Dc2ov 0.570 n 4218 16.36 0 0 0 0 0 0 0 0
11 11D0 0.390 n 28.85 8.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
12C-05w 0.091 a 6.73 1.50 0 0 0 0 90 78 525 117
1D-c2Dv 0.570 a 4218 58.17 0 0 0 0 12 0 508 696
1N 15B-853c8 0.100 a 5.92 0.18 0 0 0 0 0 0 0 0
�G 1D-c2ov 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
ILG12C-0sw 0.091 5 6.73 1.50 0 0 0 0 0 0 0 0
1Dc2(yv 0.570 s 4218 30.57 0 0 0 0 0 0 0 0
TE15B-8S3c-6 0.100 5 5.97 0.21 0 0 0 0 0 0 0 0
OD 10c20v 0.570 5 42.18 30.57 0 0 0 0 0 0 0 0
11DO 0.390 s 28.86 8.38 0 0 0 0 0 0 0 0
12C-0sw 0.091 w 6.73 1.50 0 0 0 0 0 0 0 0
1Dc2ov 0.570 w 4218 5&17 0 0 0 0 0 0 0 0
141 15B-8s3c6 0.100 w 5.96 0.20 0 0 0 0 0 0 0 0
I�----GD 1Dc2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
1100 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 16B30ad 0.032 - 237 1.44 50 50 118 72 110 110 260 158
C 16B-30ad 0.032 - 237 1.44 0 0 0 0 0 0 0 0
F 19A-19bscp 0.049 - 284 0.38 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AEDexcursion _14 -109
Emdope loss/gain 421 126 2384 1191
12 a) Inriftratim 199 12 835 51
b) Room ventilation 0 0 0 0
13 Ihtemal gains: Occupants Q 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines a to 13) 620 138 3219 1242
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistributim 0 0 0 0
14 Subtotal 620 138 3219 1242
15 Dud loads 9% 5% 54 7 9% 5% 281 62
Totn k
al roan 674 145 3500 1304
Air required(cfm) 10 7 49 59
Calculations approved by ACCA to meet all requirements Of Manual J 8th Ed.
c Wrl htsOTY R 2017-Mer-0610:36:42
9 Right-Sue.®Universal 2017 17.0.16 RSU25116 Page 8
...erslscott.langeworthy\Dmuments\York\SEEBER.mp CeIc=MJ8 Front Door faces: N
Right-J® Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY,NY 12804
1 Room name Roon18 Rccm21
2 Exposed wall 30.0 ft 11.0 ft
3 Room height 9.0 It heal/cool 9.0 ft test/000l
4 Room dimensions 120 x 18.0 ft 7.0 x 17.0 ft
5 Room area 216.0 ft- 119.0 ft'
Ty I Constmction U-value Or HTM Area (ftp Load Area (ft) Load
number (BtuNft;°F) (Btulvft� or perimeter (ft) (Bluh) a perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Heat Cod Gmss N/P/S Heat Cod
6 1p/ 12C-Osw 0.091 n 6.73 1.50 0 0 0 0 0 0 0 0
�G 113Qov 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
15B-8s3c-6 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1 D-c2ov 0.570 n 42.18 16.36 0 0 0 0 0 0 0 0
11 11D0 0.390 n 28.86 6.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
12C-Osw 0.091 a 6.73 1.50 162 134 902 201 18 18 121 27
1Dc2ov 0.570 a 4218 58.17 28 0 1181 1629 0 0 0 0
Y---G
15B-8s3c6 0.100 a 5.92 0.18 0 0 0 0 0 0 0 0
tai 113 c20v 0.570 a 4218 68.17 0 0 0 0 0 0 0 0
12C-Osw 0.091 s 6.73 1.50 108 80 539 120 63 51 343 77
113c2ov 0.570 s 4218 30.57 28 0 1181 856 12 0 506 367
16 15B-8s3c-6 0.100 s 5.97 0.21 0 0 0 0 0 0 0 0
1D-c2ov 0.670 s 42.18 30.57 0 0 0 0 0 0 0 0
11D0 0.390 5 28.86 8.38 0 0 0 0 0 0 0 0
w 12C-Osw 0.091 w 6.73 1.50 0 0 0 0 18 18 121 27
�-G 1Dc2ov 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
158-8s3c-6 0.100 w 5.96 0.20 0 0 0 0 0 0 0 0
GD 1D-c2w 0.570 w 4218 58.17 0 0 0 0 0 0 0 0
l
1100 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 16BJO9d 0.032 - 237 1.44 216 216 511 311 119 119 282 171
C 16B-30ad 0.032 - 2.37 1.44 0 0 0 0 0 0 0 0
F 19A-19bscp 0.049 - 2.84 0.38 0 0 0 0 2 2 8 1
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AED excursion -284 45
Envelope loss/gain 4315 2833 1379 715
12 a) Infiltration 1194 73 438 27
b) Roan ventilation 0 0 0 0
13 Imemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 5508 2905 1617 741
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 5508 2905 1817 741
15 Dud loads 1 9'/65% 481 145 9% 5% 159 37
Trial roan load 5989 3050 1976 778
Air required(cfm) 84 138 28 35
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.righLSOft- 2017-Mar-06 10:36:42
P. Right-Suae®Universal 2017 17.0.16 RSU25116 Page 9
...emkscolt.langeworthy\Documents\York1SEEBER.mp Calc=MJ8 Front Doorfaces: N
Right-J® Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY,NY 12804
1 Room name Rcan22 Roan23
2 Exposed wall 120 ft 6.0 ft
3 Roan height 9.0 It heal/cod 9.0 It te@Vcod
4 Rain dimensions 120 x 12.0 ft 6.0 x 120 1t
5 Room area 144.0 ft' 720 ft'
Ty Construction U-value Or HTM Area (ft-) Load Area (W) Load
number (BtdVft'-°F) (Btdvft'j a perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
HeatCod Gross WP/S Heat Cod Gross WP/S Hint Cod
8141 12C-0sw 0.091 n 6.73 1.50 0 0 0 0 0 0 0 0
--G 1Dc2ov 0.570 n 4218 18.36 0 0 0 0 0 0 0 0
15B-853c-6 0.100 n 5.86 0.16 0 0 0 0 0 0 0 0
1Dc2ov 0.570 n 4218 16.36 0 0 0 0 0 0 0 0
11 1100 0.390 n 28.86 8.38 0 0 0 0 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0 0 0 0 0
Vfl 12C-0sw 0.091 a 6.73 1.50 0 0 0 0 0 0 0 0
T-G iDc2ov 0.570 a 42.18 58.17 0 0 0 0 0 0 0 0
V,J 15B-853c8 0.100 a 5.92 0.18 0 0 0 0 0 0 0 0
t-G 1Dc2ov 0.570 a 4218 58.17 0 0 0 0 0 0 0 0
W 12C-0sw 0.091 3 6.73 1.50 108 84 586 125 54 54 364 81
�I-1-G 1D-c2ov 0.570 s 4218 30.57 24 0 1012 734 0 0 0 0
`D 15B-893o6 0.100 5 5.97 0.21 0 0 0 0 0 0 0 0
1Dc2ov 0.570 s 42.18 30.67 0 0 0 0 0 0 0 0
1100 0.390 s 28.86 8.38 0 0 0 0 0 0 0 0
N/ 12C-Osw 0.091 w 6.73 1.50 0 0 0 0 0 0 0 0
---G 1D-c2ov 0.670 w 4218 58.17 0 0 0 0 0 0 0 0
l4/ 15B-0s3c6 0.100 w 5.96 0.20 0 0 0 0 0 0 0 0
I�-(D; 1Dc2ov 0.570 w 42.18 58.17 0 0 0 0 0 0 0 0
11DO 0.390 w 28.86 8.38 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 237 1.44 144 144 341 207 72 72 170 104
C 16B-30ad 0.032 - 237 1.44 0 0 0 0 0 0 0 0
F 194-tgbscp 0.049 - 284 0.38 0 0 0 0 72 72 205 28
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0 0 0 0 0
6 c)AED excursion 116 -20
Envelope loss/gain 1919 1183 1 739 192
12 a) Infiltration 477 29 239 15
b) Roam ventilation 0 0 0 0
13 Internal gains: Occupants 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2396 1212 977 207
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2396 1212 977 207
15 Dud loads 9% 5% 209 60 9% 5% 85 10
Total roan load 2806 1273 1063 217
Air required(dm) 37 57 1 15 10
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
c wri htSofC 2017-Mar-0610:3642
9 Right-Salta®Universal 2017 17.0.16 RSU25116 Page 10
...ers\scott.langmorthy\Documents\York\SEEBER.rup Calc=MJ8 Front Door faces: N
Right-JO Worksheet Job: SEEBER
Entire House Date: Mar 06,2017
By: SCOTT
CERRONE P&H Plan: 1226
QUEENSBURY,NY 12804
1 Room name Roan24
2 Exposed wall 0 ft
3 Room height 9.0 ft heaVcod
4 Room dimensions 1.0 x 101.0 ft
5 Room arm 101.0 ft'
Ty Ccrstrwion U-value Or HTM Ansa (ftj Load Area Load
number (BtuWWF) (Btutvft� or perimeter (ft) (Btuh) a
pedmoter
Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool
612C-Osw 0.081 n 6.73 1.50 0 0 0 0
1Dc20v 0.570 n 4218 18.38 0 0 0 0
15B3s3a6 0.100 n 5.86 0.16 0 0 0 0
1Dc2ov 0.570 n 4218 16.36 0 0 0 0
11 1100 0.390 n 28.86 8.38 0 0 0 0
11P0 0.290 n 21.46 6.23 0 0 0 0
12C-0sw 0.091 a 6.73 1.50 0 0 0 0
1Dc2ov 0.570 a 4218 68.17 0 0 0 0
w 15B-8s3c-6 0.100 a 5.92 0.18 0 0 0 0
L-G 1Dc2ov 0.570 a 4218 58.17 0 0 0 0
t12C-0sw 0.091 s 6.73 1.50 0 0 0 0
-(3 1Dc2w 0.570 s 4218 30.57 0 0 0 0
ti15B-853c-6 0.100 5 5.97 0.21 0 0 0 0
1Dc2ov 0.570 s 42.18 30.57 0 0 0 0
11DO 0.390 s 28.86 8.38 0 0 0 0
12C-0sw 0.091 w 6.73 1.50 0 0 0 0
1Dc2ov 0.570 w 4218 58.17 0 0 0 0
lql 15B-8s3c-6 0.100 w See 0.20 0 0 0 0
F�-CD 1Dc2ov 0.570 w 4218 56.17 0 0 0 0
1100 0.390 w 28.86 8.38 0 0 0 0
C 16B30ad 0.032 - 237 1.44 101 101 239 145
C 16B-30ad 0.032 - 237 1.44 0 0 0 0
F 19A-19bscp 0.049 - 284 0.38 24 24 68 9
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0
F 21A-24t 0.025 - 1.85 0.00 0 0 0 0
6 c)AED exc rsion -14
Envelope loss/gain 307 141
12 a) lnrlhratlon 0 0
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 307 141
Less external load 0 0
Less transfer 0 0
Red isthbotion 0 0
14 Subtotal 307 141
15 Dud loads 9% 5% 27 7
Total room load 334 148
Air req.,d(cfm) 5 7
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrightsofC 2017-Mar-0610:36:42
Rigor-SU rk\SEE Universal 17.0.16 RSU25116 Page 11
...ars\scott.langewonhy\Documents\Vont\SEEBER.rup CeIc=MJB Front Door/aces: N
1
CREScheck Software Version 4.6.2
�(J Compliance Certificatep E C E o e
EDMAR 0 2 1017
Project Seeber Residence TOWN OF
C
COMMUNITYDEVELOPMENT
E Y
Energy Code: 2015 IECC
Location: Warren County, New York
Construction Type: Single-family
Project Type: New Construction 301.17-3-56 RC 78-2017
Conditioned Floor Area: 3,081 ft2
Glazing Area 14% Collette Construction Inc.
Climate Zone: 6 (8499 HDD) Lot 9, House No. 41 Caitlin Drive
Permit Date:
Permit Number: SFD wl att. garage, 1 -gas fp
Construction Site: Owner/Agent: Designer/Contractor:
Caitlin Drive Collette Construction VISION Engineering, LLC
Queensbury, NY 12804 206 Glen Street
Suite 56
Glens Falls, NY 12801
Compliance: Passes using UA trade-off
Compliance. 0.0%Better Than Code Maximum UA: 445 Your UA: 445
The%Better or Worse Than Code lydex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Assembly or Cavity Cant. U-Factor UA
Ceiling 1: Raised or Energy Truss 1,788 38.0 11.0 0.020 36
Floor 1: All-Wood joist/rruss:Over Unconditioned Space 553 38.0 0.0 0.026 14
Basement Wall 1: Solid Concrete or Masonry 1,584 0.0 15.0 0.047 72
Wall height: 8.8'
Depth below grade: 7.8'
Insulation depth: 8.0'
Window 1: Vinyl/Fiberglass Frame:Double Pane 6 0.400 2
Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.300 5
Door 1: Solid 20 0.200 4
Wall 1: Wood Frame, 16" o.c. 1,800 21.0 0.0 0.057 87
Window 3:Wood Frame:Double Pane with Low-E 188 0.300 56
Door 2: Solid 20 0.140 3
Door 3: Glass 40 0.300 12
Door 4: Glass 34 0.200 7
Wall 2: Wood Frame, 16" D.C. 1,704 21.0 0.0 0.057 85
Window 4: Wood Frame:Double Pane with Low-E 207 0.300 62
Project Title: Seeder Residence Report date: 03/01/17
Data filename: C:\Users\Irobision\Desktop\1226 Reschecii Page 1 of 10
Compliance Statement: The proposed building design i e here is consistent with the building plans,specifications,and other
calculations submitted with the permit application a propo d b ' p has been designed to meet the 2015 IECC requirements in
REScheS\krypI`r5i n 4.6.2 a to comply withth andatory men rS listed in the Ehespection Checklist
Name-Title Si re D t3 e
c NCjI,
�P
EL W. Y�
Oj QP yy2'per
tr
ul
w
,o 0- 0790
Project Title: Seeber Residence Report date: 03/01/17
Data filename: C:\Users\Irobision\Desktop\1226 Rescheck.rck Page 2 of 10
REScheck Software Version 4.6.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Pield Verified
# Pre-Inspection/Pian Review Value .. Value Complies? Comments/Assumptions
&Req.ID _
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate "'❑Does Not
[PRIll energy code compliance for the
❑Not Observable
,enveiopng erepresetedonal ,.:;❑NotApplicable
envelope represented on
construction documents.
103.1, Construction drawings and 1❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR311 lighting and mechanical systems ❑Not Observable 1
Systems serving multiple ❑Not Applicable j
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
1119212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
Manual J or other methods Btu/hr_ Btu/hr ❑Not Applicable
approved by the code official.
Additional Comments/Assumptions:
111 High Impact(Tier 1) Medium Impact(Tier 2) 3.1 Low Impact(Tier 3)
Project Title: Seeber Residence Report date: 03/01/17
Data filename: CAUsers\Irob ision\Desktop\1226 Rescheck.rck Page 3 of 10
Section Plans Verified Field Verified
# Foundation inspection Value Value Complies? CommentslAssumptions .
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[F0411 :insulation R-value.Where interior R_ R- ❑Does Not :table for values.
insulation is used,verification ❑Not Observable .
may need to occur during
Insulation Inspection. Not ❑Not Applicable j
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[F0511 ;insulation installed per ❑Does Not
0 j manufacturer's instructions. ❑Not Observable
❑Not Applicable
402.2.9 ;Conditioned basement wall ft ft ❑Complies !See the Envelope Assemblies
[F0611 ;insulation depth of burial or ❑Does Not ;table for values,
distance from top of wall. [--]Not Observable
❑Not Applicable j
OF012ft A protective covering is installed ❑Complies
to protect exposed exterior ❑Does Not
insulation and extends a ❑Not Observable
minimum of 6 in, below grade.
El Not Applicable
Snow-and ice-melting system ❑Complies
installed. []Does Not
U>J ❑Not Observable
❑Not Applicable j
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Seeder Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 4 of 10
Section - Plans Verified Fleld Verified
# Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
&:Req.ID _
402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FRI]' ❑Not Observable
kt ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U-_ U-_ ❑Complies see the Envelope Assemblies
402.3.1, average), ❑Does Not table for values.
402.3.3,
❑
402.3.6, Not Observable
402.5 ❑Not Applicable
[FR211
303.1.3 U-factors of fenestration products :. - ❑Complies
-
[FR411 are determined in accordance
MO Not
'z
with the NFRC test procedure or --;❑Not Observable
-taken from the default table.
❑Not Applicable j
402.4.1.1 'Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable
❑Not Applicable j
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting []Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code - ❑Not Applicable j
limits.
402140.O IC-rated recessed lighting fixtures. ❑Complies
[FN'16]2 -"sealed at housing/interior finish ❑Does Not
and labeled to indicate s2.0 cfm ❑Not Observable I
`leakage at 75 Pa. ❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]' -insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where < 3 inches.Supply and []Not Observable
return ducts in other portions of ❑Not Applicable j
:the building insulated >=R-6 for
diameter>= 3 Inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R-_ R- ❑Complies
[FR17]1 above 105 QF or chilled fluids ❑Does Not
.,� below 55 QF are insulated to alk-
3.
❑Not Observable
❑Not Applicable j
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. it " Si�Y Ili. '�,�1t"4 a`f' sl�..�.-
❑Does Not
!� ❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R-_ R-_ ❑Complies
[FR18]2 aR-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
(FR19)2 installed on all outdoor air - ❑Does Not
intakes and exhausts. ;.?. ❑Not Observable
" '"`�'P❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Seeber Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 5 of 10
Additional Comments/Assumptions:
1 I High Impact(Tier 1) Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: seeber Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 6 of 10
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
303.1. All installed insulation is labeled ❑Complies
[IN1312 or the installed R-values =❑Does Not
provided. ❑Not Observable
.;:❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies 'See the Envelope Assemblies
402.2.6 ❑ Wood F-1 Wood ❑Does Not ,.table/or values.
[IN111 ❑ Steel ❑ Steel ❑Not Observable
V, ❑Not Applicable
303.2, Floor insulation installed per - ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the Observable
underside of the subfloor,or floor ❑Not Applicable❑Not Obsrvabl j
'framing cavity insulation is in
contact with the top side of
sheathing,or or continuous
insulation is installed on the
underside of floor framing and
,extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R-_ R- .. ❑Complies See the Envelope assemblies
402.2.5, mass wall with at least 1h of the !❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 Wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN311 exterior,the exterior insulation
i requirement applies(FR10), j❑ Steel ❑ Steel ❑Not Applicable j
303.2 Wall insulation is installed per - ❑Complies
[IN411 manufacturer's instructions. ❑Does Not
[]Not Observable
❑Not Applicable j
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Seeber Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 7 of 10
Section Plans Vered Field Verged
# Final Inspection Provisions Value Value, Complies? Comments/Assumptions.:
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope assemblies
402.2.1, ❑Wood ❑ Wood ❑Does Not table for values.
402'2'2• ❑ Steel ❑ Steel []Not Observable
402.2.6
[FIl]1 ❑Not Applicable
303.1.1.1, iCeiling insulation installed per ❑Complies
303.2
.manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft'. ❑Not Observable
❑Not Applicable
Vented attics with air permeable ❑Complies
insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
:❑Not Applicable ,
402.2.4 ;Attic access hatch and door R- R- ❑Complies
[F13]1 ;insulation aR-value of the ❑Does Not
;adjacent assembly. ❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ❑Complies
IFI1711 'ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3.8. ;[]Not Observable
❑Not Applicable
403.2.3 ;Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 'cfm/100 ft2 across the system or ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
:handler @ 25 Pa.For rough-in
'tests,verification may need to ❑Not Applicable j
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F12711 determine air leakage with ft2 ! ftp ❑Does Not
either: Rough-in test:Total ❑Not Observable
leakage measured with a
pressure differential of 0.1 inch ❑Not Applicable
j w.g.across the system including
'the manufacturer's air handler
'enclosure if installed at time of
test.Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies I
[FI24]1 by manufacturer at<=2%of ❑Does Not
design air flow. ❑Not Observable
❑Not Applicable
403.1:1 :Programmable thermostats ❑Complies
[9911 installed for control of primary ❑Does Not
heating and cooling systems and ❑Not Observable 1
initially set by manufacturer to
code specifications. ❑Not Applicable j
403.1.2 Heat pump thermostat installed ❑Complies
[FI1011 on heat pumps. ❑Does Not
❑Not Observable i
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
[Flll]2 systems have automatic or ❑Does Not
accessible manual controls. ❑Not Observable
❑Not Applicable j
High Impact(Tier 1) 2._ Medium Impact (Tier 2) 3 Low Impact(Tier 3)
Project Title: Seeber Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 8 of 10
Section Plans Verified Field Verified
#- Final Inspection Provisions Value 'Value Complies? Comments/Assumptions
& Req.iD _ _
403.6.1 All mechanical ventilation system ❑Complies
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. .I ❑Not Observable
'-❑Not Applicable j
403.2 Hot water boilers supplying heat ~''.❑Complies
[F12617 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable ;
temperature based on outdoor ❑Not Applicable j
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply
pipe.Gravity and thermos- ❑Not Applicable I
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically ❑Not Observable
adjust the energy input to the
heat tracing to maintain the `.❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that [ Complies
[F130]2 have recirculation pumps that ❑Does Not
pump water from a heated water ❑Not observable
supply pipe back to the heated
water source through a cold []Not Applicable j
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104QF.
403.5.4 Drain water heat recovery units - [ Complies
[F13112 tested in accordance with CSA ❑Does Not
B55.1.Potable water-side ❑Not Observable
pressure loss of drain water heat
recovery units<3 psi for -'.[]Not Applicable j
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers. _
404.1 75%of lamps in permanent ❑Complies
[FI6I1 fixtures or 75%of permanent '.❑Does Not
fixtures have high efficacy lamps. '
Does not apply to low-voltage ;'t❑Not Observable
lighting. „[]Not Applicable
404.1.1 .Fuel gas lighting systems have I❑Complies
[FI2313 no continuous pilot light. ;❑Does Not
`y
[]Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Seeber Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 9 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies
[FI712 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided. ❑Not Observable l
❑Not Applicable j
Additional Comments/Assumptions:
1 I High Impact(Tier 1) ,Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Seeber Residence Report date: 03/01/17
Data filename: C:\Users\lrobision\Desktop\1226 Rescheck.rck Page 10 of 10
2015 IECC Energy
Efficiency Certificate
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 38.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating 1.1-Factor
Window 0.30
Door 0.30
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
RAJNY onsulfing, LLC
69 Hayden Point Loop
Diamond Point, NY 12824
518 221-3240
10/06/2017 D E C E 0 V E
Collette Construction
OCT 0 6 2017
38 Collette Lane TOWN OF QUEENSBURY
Hudson Falls,NY 12839 BUILDING&CODES
R.C,-0-+b- 2Q VV
Inspection Address: 41 Caitlin Drive, Queensbury NY 12804
Report Number: 0927171
Dear Ken:
The Blower Door Test to verify infiltration rate of the subject property was performed on
10/06/2017. This was done to verify mandatory requirements of 2015 IECC Code as
amended by the NYS Uniform Code Supplement. This report does not imply that full
compliance of above codes has been met.It's verified the infiltration rates only.
GRAJNY Consulting,LLC is pleased to submit the following report.
The following data was provided:
- Square Footage of the house,including conditioned basement=4,464 SF
- Volume of the house,including conditioned basement=39,758 CF
Based on above,the following test data was collected:
- Infiltration Rate,including conditioned basement at 50 Pascal= 1,852 CFM
- ACH50,Actual Changes per Hour at 50 Pascal= 1,852X60/39,758=2.79<3
The Instruments used for test were provided by the Energy Conservatory Digital Gauge
DG-3 rated accuracy=+/- I%,calibrated minimum once per year.
Thank you for selecting our company. We appreciate the opportunity to be of service.
Please call this office if there are any questions.
Sincerely,
stag 0.54,0
Stan Grajny, PE
RESNET HERS Energy Rater 5609922
NYS PE 065406-1