REScheck Compliance Certificate at
New York State Energy Conservation Construction Co
REScheckSoftware Version 3.5 Release 1c
Data filename:C:\Program Files\Check\REScheck\brookwood.rck
TITLE:The Brookwood
COUNTY: Warren
STATE:New York
HDD:7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE: 06/09/05
DATE OF PLANS:June 2005
PROJECT INFORMATION:
All
COMPANY INFORMATION:
Hayes Construction Group
COMPLIANCE: Passes
Maximum UA=561
Your Home UA=458
18.4%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 1618 30.0 0.0 57
Ceiling 2:Cathedral Ceiling(no attic) 128 30.0 0.0 4
Wall 1:Wood Frame, 16"o.c. 1476 19.0 0.0 74
Window 1:Vinyl Frame:Double Pane with Low-E 160 0.370 59
Door I:Glass 34 0.350 12
Door 2: Solid 20 0.140 3
Door 3:Glass 36 0.320 12
Wall 2:Wood Frame, 16" o.c. 1358 19.0 0.0 72
Window 2: Vinyl Frame:Double Pane with Low-E 152 0.370 56
Basement Wall 1: Solid Concrete or Masonry 1139 0.0 10.0 95
Wall height:7.8'
Depth below grade:6.8'
Insulation depth:4.0'
Floor l:All-Wood Joist/Truss:Over Unconditioned Space 320 30.0 0.0 11
Floor 2:All-Wood Joist/Truss:Over Outside Air 95 30.0 0.0 3
Furnace 1: Forced Hot Air,92 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,
specifications are in compliance 'th Code. p J gmen[,such plans or
Builder/Designer Date
OF NEi
* 2 �
r
m w
=`a
IP�OA 07906
9DFEs s I oNP�
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release lc
DATE:06/09/05
TITLE:The Brookwood
Bldg.
Dept.
Use
I
Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] I 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation
Comments:
I
I Above-Grade Walls:
[ ] I 1. Wall ]: Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ J 2. Wall 2: Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
I
I Basement Walls:
[ ] I 1. Basement Wall 1: Solid Concrete or Masonry,7.8'ht/6.8'bg/4.0'insul,
R-10.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in. below grade.
I
Windows:
[ ] I 1. Window l:Vinyl Frame:Double Pane with Low-E,U-factor:0.370
For windows without labeled U-factors,describe features:
#Panes_Frame Type Thermal Break? [ ]Yes[ ]No
Comments:
[ ] I 2. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.370
For windows without labeled U-factors,describe features:
#Panes_Frame Type Thermal Break? [ ] Yes[ ]No
Comments:
I
Doors:
[ ] I I. Door 1:Glass,U-factor: 0.350
Comments:
[ J I 2. Door 2:Solid,U-factor: 0.140
Comments:
[ ] I 3. Door 3: Glass,U-factor: 0.320
Comments:
I
Floors:
[ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
[ J I 2. Floor 2:All-Wood Joist/Truss:Over Outside Air,R-30.0 cavity insulation
Comments:
I
Heating and Cooling Equipment:
[ ] I 1. Furnace 1:Forced Hot Air,92 AFUE or higher
Make and Model Number
I
I Air Leakage:
[ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
I with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a
I 3"clearance from insulation.
I
I Vapor Retarder:
( ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
I
I Materials Identification:
[ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
( ] I Materials and equipment must be identified so that compliance can be determined.
( 1 I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] I Insulation R-values,glazing U-factor;, and heating equipment efficiency must be clearly marked on
I the building plans or specifications.
I
I Duct Insulation:
[ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
( ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6.
( ] I Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
I
I Duct Construction:
[ l I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
I Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
I operating at less than 2 in,w.g. (500 Pa).
( ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I
Air filters are required in the return air system.
[ l I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
I
I Electric Systems:
[ ] I Separate electric meters are required for each dwelling unit.
I
I Fireplaces:
[ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
I provisions of the Building Code of New York State ,the Residential Code of New York State or
the New York City Building Code ,as applicable.
I
I Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
I Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ J I All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5