Loading...
ResCheck Rhec r REScheck Compliance Certificate at New York State Energy Conservation Construction Co REScheckSoftware Version 3.5 Release 1c Data filename:C:\Program Files\Check\REScheck\brookwood.rck TITLE:The Brookwood COUNTY: Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 06/09/05 DATE OF PLANS:June 2005 PROJECT INFORMATION: All COMPANY INFORMATION: Hayes Construction Group COMPLIANCE: Passes Maximum UA=561 Your Home UA=458 18.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1618 30.0 0.0 57 Ceiling 2:Cathedral Ceiling(no attic) 128 30.0 0.0 4 Wall 1:Wood Frame, 16"o.c. 1476 19.0 0.0 74 Window 1:Vinyl Frame:Double Pane with Low-E 160 0.370 59 Door I:Glass 34 0.350 12 Door 2: Solid 20 0.140 3 Door 3:Glass 36 0.320 12 Wall 2:Wood Frame, 16" o.c. 1358 19.0 0.0 72 Window 2: Vinyl Frame:Double Pane with Low-E 152 0.370 56 Basement Wall 1: Solid Concrete or Masonry 1139 0.0 10.0 95 Wall height:7.8' Depth below grade:6.8' Insulation depth:4.0' Floor l:All-Wood Joist/Truss:Over Unconditioned Space 320 30.0 0.0 11 Floor 2:All-Wood Joist/Truss:Over Outside Air 95 30.0 0.0 3 Furnace 1: Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment, specifications are in compliance 'th Code. p J gmen[,such plans or Builder/Designer Date OF NEi * 2 � r m w =`a IP�OA 07906 9DFEs s I oNP� REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE:06/09/05 TITLE:The Brookwood Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] I 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: I I Above-Grade Walls: [ ] I 1. Wall ]: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ J 2. Wall 2: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: I I Basement Walls: [ ] I 1. Basement Wall 1: Solid Concrete or Masonry,7.8'ht/6.8'bg/4.0'insul, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in. below grade. I Windows: [ ] I 1. Window l:Vinyl Frame:Double Pane with Low-E,U-factor:0.370 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] I 2. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.370 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ ]No Comments: I Doors: [ ] I I. Door 1:Glass,U-factor: 0.350 Comments: [ J I 2. Door 2:Solid,U-factor: 0.140 Comments: [ ] I 3. Door 3: Glass,U-factor: 0.320 Comments: I Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: [ J I 2. Floor 2:All-Wood Joist/Truss:Over Outside Air,R-30.0 cavity insulation Comments: I Heating and Cooling Equipment: [ ] I 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number I I Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly I with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a I 3"clearance from insulation. I I Vapor Retarder: ( ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ( ] I Materials and equipment must be identified so that compliance can be determined. ( 1 I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values,glazing U-factor;, and heating equipment efficiency must be clearly marked on I the building plans or specifications. I I Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ( ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. ( ] I Supply ducts in unconditioned spaces must be insulated to R-11. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I I Duct Construction: [ l I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. I Exception:Continuously welded and locking-type longitudinal joints and seams on ducts I operating at less than 2 in,w.g. (500 Pa). ( ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ l I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. I I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction I provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. I I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ J I All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)