Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-000436-2015
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 vt Community Development-Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000436-2015 Date Issued: Friday, May 13, 2016 This is to certify that work requested to be done as shown by Permit Number CC-000436-2015 has been completed. Tax Map Number: 296.15-1-2 Location: 93 GENTRY LN Owner: Schemerhotn Properties Applicant: Schermerhorn Properties This structure may be occupied as a: Townhouse 8 units w/garage & fireplace By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 Q— Wrr, BUILDING PERMIT Permit Number: CC-000436-2015 2Z14C ' /A 23 Tax Map No: 296.15-1-2 REVISED Permission is hereby granted to: Schermerhom Properties For property located at: 93 GENTRY LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Schemerhom Properties Multi-Family-New $200,000.00 Owner Address: 536 Bay RD,Suite 2 Total Value $200,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Richard Schennerhom 536 Bay RD,2 Queensbury,NY 12804 Plans&Specifications Townhouse 8 units w/garage&fireplace PERMIT FEE PAID-TMS PERMIT EXPIRES: Friday,September 16,2016 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of edne ptember 17,2014 SIGNED BY: \( (N?� /Vfor the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE OMU! � 1 1 AY .dAP NO. PEPIt41T NO. FEES: PERMIT �3RE ; _C,.�r,TlON��E�!GlidcERlN% � :L,{ (If applicable)_. . ' f717-_.-__------ PRYpp X ' NCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OFAA,V,AUD PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: -�RCfdrrt'0 �.] MA OWNER: ADDRESS: �J O 15A-f &AO W82 22 ADDRESS: PHONE NO PHONE NOS.,y, CONTACT PERSON FOR BUILDING&CODES COMPLIANCE i� _ix PHONE: LOCATION OF PROPERTY: 1W1#461 a& —1 q lam,. t. 1a 6 MNft ILL, HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? Z YES ❑ NO�"�- IF SO, INDICATE APPLICATION NO.AND DATE OF APPROVAL- PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT Z APPLY TO YOUR Z 0 Cf Uj F PROJECT 0 p p 1-: co CD Cn 1-:LL w o w � t LLw w ¢ aa..Zc=i w o m C+ i d HF ~ O� z z a ¢ ern C14 10 Ow ° � a= SINGLE FAMILY TWO-FAMILY (NO.MULTI-FAMILYoUNI � (NO.of UNITS 1 1 V TOWNHOUSE BUSINESS OFFICE I i I D RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED / ElATAI II GARAGE(1,2,3) OTHER Town of Queensbury Community Development Office a 742 Bay Road, Queensbury NY 12804 Revised 4/14/2010 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: C&rm/ m Wy( jpWghlises ESTIMATED CONSTRUCTION COST:6low FUEL TYPE: 04-(; S HEAT TYPE:=HOW MANY FIREPLACE(S):_$_AND/OR WOODSTOVES(S):_- ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?IS THIS A HISTORIC SITE? NQ PROPOSED USE OF BUILDING OR ADDITION: -ktA)t.14u6r- i�y f 5-`_ ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? /"r �6 ►��t�7V ARE THERE EASEMENTS ON PROPERTY? Fno construction activities shall be commenced prior to issuance of a valid ify that the application, plans, and supporting materials are a true and mentldescrfption of the work proposed, that all work will be performed in ith the NY State Building Codeslocal building laws and ordinances, and in with local zoning regulations. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate Of Occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree t h above. Signed r► ��7i7- (.�' � ")�s�/'�.lG/OY1/g— / Town of Queensbury` Community Development Office742 Bay Road, Queensbury NY 12804 Office Use Only Town of Queensbury Building & Codes Received; Tax I : FUEL BURNING APPLIANCE&CHIMNEY APPLICATION PermitalloD Permit Fee: $ Application is hereby made to the Building & Codes Office for the issuance of a Building & Use Permit pursuant to the NYS Fre Prevention & Building Code. The applicant or owner agrees to comply with all apptipble laws,ordinances, regulations, and all conditions that are part of these requirements and also xn71 allow all inspectors t0 enter premises to perform required inspections. lmgortant Note ToAgollcant Rough In and Final Inspections Required Date e Owner ik Installer/Builder dye ytZ� Address I. .,,����� Address Phone Phone Location of proposed construction and/or installation: AILL Contact Person for Building&Codes Compliance: t A4M 44141 � i4ALr Subdivision Name: 6 l Fuel Buming Appliance Information Wood Coal Pellet Gas Oil Stove Fire lace Insert Fire lace,facto built' Fi lace,Mason Furnace,(Ga ra a Onl If Factory Built,Please Provide: Manufacturer Name: A—WModel No. Listed By: Number. _ Chimney Information Masonry` ✓check one —Brock —B° —Stone Flue ✓check one —Tile —Steel Size in Inches Material ✓check one _Double Wall —Tr ple Wa11 —Insulated Direct Vent —Chimney Liner If Non-Masonry,please provide: Manufacturer Name: —�_ Model No. Signatures: Print Name: Signature: Ift Date: ADDITIONAL NOTE: CONSTRUCTIONANSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURER REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. c Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000436-2015 Case Module: Permit Inspection Date: 05/13/2016 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: OCC-Inspections Job Address: 93 GENTRY LN Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Contractor Schermerhorn,Richard Granted Permission [Schermerhorn Properties] Applicant [Schermerhorn Properties] Primary Owner [Schemerhorn Properties] Checklist Item Passed Comments Sprinkler System Annual-Sprinkler System Annual YES Received NFPA 13 letter from FireTek dated 4/28/16 Truss ID Signage FC505.3-TRUSS ID SIGNAGE FC505.3 YES Verified Smoke Detectors FC907-Smoke Detectors FC907 YES Verified and tested Interior Finishes FC803-804-Interior Finishes FC803-804 YES F.D.Signage-FC510-F.D.Signage-FC510 YES Combustibles in Equipment Rooms FC 315.2.3-Combustibles in YES Equipment Rooms FC 315.2.3 Clearance to Sprinkler/Ceiling FC315.2.1 18"/24"-Clearance to YES Sprinkler/Ceiling FC315.2.1 18"/24" Sprinkler FDC-Sprinkler FDC YES Electrical Wiring Enclosed/Labeled FC605.3.1 -Electrical Wiring YES Enclosed/Labeled FC605.3.1 CO Detectors FC610-CO Detectors FC610 YES Verified and tested Knox Box:installed/checked FC506-Knox Box:installed/checked YES FC506 Stillman,Gary(Inspector) May 13,2016 Page(6) )41 -t�3 . -1 COMcheck Software Version 3.9.2 Envelope Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information ' 2014 Project Type: New Construction - Project Title : New Townhouse Apartment Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Dnve Schermerhom Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schemerhommnstmetion.com 518-580-1905 ephall@nycap.rr.com Section 2: General Information Building Location(for weather data): Warren,New York Climate Zone: 6a Building Space Conditioning Type(s): Nonresidential ' " Vertical Glazing/Wall Area Pd.: 12% p "{!j AGtivllv_Typg(s) F_IQ9r Area Multifamily 12330 Section 3: Requirements Checklist Envelope PASSES: Design 5%better than code.Requirements: Component Name/Description Gross Cavity Cont. Proposed Budget Area or R-Value R-Value U-Factor U-Factona) Perimeter Orientation: NORTH Exterior Wall 3:Wood-Framed,16"o.c. 1070 21.0 0.0 0.062 0.051 Door 17:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 18:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 19:Insulated Metal,Swinging 18 0.300 0.700 Door 20:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 21:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 40 - - 0.290 0.350 Door,SHGC 0.65 Exterior Wall 4:Wood-Framed,16"o.c. 384 21.0 0.0 0.062 0.051 Orientation:EAST Exterior Wall 1:Wood-Framed,16"o.c. 1560 21.0 0.0 0.062 0.051 Door 1:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 2:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 3:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 4:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 5:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 6:Insulated Metal,Swinging 20 0.300 0.700 Door 7: Insulated Metal,Swinging 20 - - 0.300 0.700 Door 8: Insulated Metal,Swinging 20 0.300 0.700 Door 9: Insulated Metal,Swinging 20 - - 0.300 0.700 Door 10:Insulated Metal,Swinging 20 0.300 0.700 Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 1 of 12 Door 11:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 12:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 13:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 14:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 15:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 16:Insulated Metal,Swinging 20 - - 0.300 0.700 Exterior Wall 2:Wood-Framed,16"o.c. 1248 21.0 0.0 0.062 0.051 Window 1:Vinyl Frame:Double Pane with Low-E,Clear,SHGC 0.65 248 - - 0.290 0.350 Orientation:SOUTH Exterior Wall 7:Wood-Framed,16"o.c. 1070 21.0 0.0 0.062 0.051 Door 28:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 29:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 30:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 31:Insulated Metal,Swinging 18 - - 0.300 0.700 Door 32:Glass(>50%glazing):Nonmetal Frame,Non-Entrance 40 - - 0.290 0.350 Door,SHGC 0.65 Exterior Wall 8:Wood-Framed,16'o.c. 384 21.0 0.0 0.062 0.051 Orientation:WEST Exterior Wall 5:Wood-Framed,16"o.c. 1560 21.0 0.0 0.062 0.051 Window 2:Vinyl Frame:Double Pane with Low-E,Clear,SHGC 0.65 217 - - 0.290 0.350 Door 22:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 23:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 24:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 25:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 26:Insulated Metal,Swinging 20 - - 0.300 0.700 Door 27:Insulated Metal,Swinging 20 - - 0.300 0.700 Exterior Wall 6:Wood-Framed,16"o.c. 1248 21.0 0.0 0.062 0.051 Window 3:Vinyl Frame:Double Pane with Low-E,Clear,SHGC 0.65 496 - - 0.290 0.350 Orientation:UNSPECIFIED ORIENTATION Roof 1:Attic Roof with Wood Joists 7014 38.0 0.0 0.027 0.027 Floor 1:Slab-On-Gmde:Unheated,Vertical ft. 529 - 10.0 - - (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Air Leakage, Component Certification,and Vapor Retarder Requirements: Lj 1. All joints and penetrations are caulked,gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's installation instructions. ❑ 2. Windows,doors,and skylights certified as meeting leakage requirements. 3. Component R-values 8 U-factors labeled as certified. 4. No roof insulation is installed on a suspended ceiling with removable ceiling panels. 5. 'Othet components have supporting documentation for proposed U-Factors. 6. Insulation installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. 7. Stair,elevator shaft vents,and other outdoor air intake and exhaust openings in the building envelope are equipped with motorized dampers. ❑ 8. Cargo doors and loading dock doors are weather sealed. ❑ 9. Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283,are sealed with gasket or caulk. ❑ 10.Building entrance doors have a vestibule equipped with self-closing devices. Exceptions: L] Building entrances with revolving doors. ❑ Doors not intended to be used as a building entrance. LJ Doors that open directly from a space less than 3000 sq.ft.in area. L] Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors. Doors opening directly from a sleeping/dwelling unit. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed envelope system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hillock Page 2 of 12 When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance wit fys Code. Ethan P. Hall-Architect 0 /to .44 Name-Title Si e4 Date a X70 Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 3 of 12 COMcheck Software Version 3.9.2 Interior Lighting Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type:New Construction Project Title: New Townhouse Apartment Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Drive Schermerhorn Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schermerhomconstmction.com 518-580-1905 ephall@nycap.rccom Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts 1 ft2 (a x C) Multifamily 12330 0.7 8631 Total Allowed Watts= 8631 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID: Description 1 Lamp I Wattage Per Lamp i Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Multifamily(12330 sq.tt.) Compact Fluorescent 1:Spiral 23W:Electronic: 1 136 32 4352 Total Proposed Watts= 4352 Section 4: Requirements Checklist Interior Lighting PASSES:Design 0%better than code. Lighting Wattage: O 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 8631 4352 YES Controls, Switching,and Wiring: Ej 2. Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. L] 3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: LJ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. O Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. U 4. Independent controls for each space(switch/occupancy sensor). Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhorn\Cottage Hill Apartments\RJT 8-plex\Cottage HIII.cck Page 4 of 12 Exceptions.- Areas xceptions:Areas designated as security or emergency areas that must be continuously illuminated. ❑ Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel/motel guest room. ❑ 6. Individual dwelling units separately metered. ❑ T. Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. ❑ 8. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires,dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps,switching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. ❑ An occupant-sensing device controls the area. ❑ The area is a corridor,storeroom,restroom,public lobby or sleeping unit. ❑ Areas that use less than 0.6 Watts/sq.ft. ❑ 9. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: ❑ Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security. ❑ 10.Photocell/astronomical time switch on exterior lights. Exceptions: ❑ Lighting intended for 24 hour use. ❑ 11.Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts). Exceptions: ❑ Electronic high-frequency ballasts;Luminaires on emergency circuits or with no available pair. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. Ethan P.Hall-Architect l �� Name-Title Signature Date Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 5 of 12 COMcheck Software Version 3.9.2 Exterior Lighting Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type:New Construction Project Title: New Townhouse Apartment Exterior Lighting Zone: 2(Residentially zoned area) Construction Site: Owner/Agent: Designer/Contractor: Cottage Hill Drive Schermerhom Residential Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schemierhomcenstruction.com 518-580-1905 ephall@nycap.mcom Section 2: Exterior Lighting Area/Surface Power Calculation A B C D E F Exterior Area/Surface Quantity Allowed Tradable Allowed Proposed Watts Wattage Watts Watts /Unit (BxC) Main entry 8 ft of door width 20 Yes 160 512 Total Tradable Watts'= 160 512 Total Allowed Watts= 160 Total Allowed Supplemental Watts"= 600 Wattage tradeoffs are only allowed between tradable areas/surfaces. A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp I Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Main entry(8 ft of door width):Tradable Wattage Compact Fluorescent 1:Spiral 23W:Electronic: 1 16 32 512 Total Tradable Proposed Watts= 512 Section 4: Requirements Checklist Lighting Wattage: O 1. Within each non-tradable area/surface,total proposed watts must be less than or equal to total allowed watts.Across all tradable areas/surfaces,total proposed watts must be less than or equal to total allowed watts. Compliance:Passes using supplemental allowance watts. Controls, Switching, and Wiring: ❑ 2. All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. ❑ 3. Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor(with time switch),or an astronomical time switch. Lj 4. Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. 5. All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 6 of 12 Exterior Lighting Efficacy: Fi 6. All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumenlwatl. Exceptions: i7 lighting that has been claimed as exempt and is identified as such in Section 3 table above. LJ Lighting that is specifically designated as required by a health or fife safety statue,ordinance,or regulation. El Emergency lighting that is automatically off during normal building operation. ❑ Lighting that is controlled by motion sensor. Section 5: Compliance Statement Compliance Statement The proposed exterior lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. J Ethan P.Hall-Architect / /b Name-Title sig a'6r Date Project Title: New Townhouse Apartment Report data:01/02/14 Data filename:Y:\Schernertwm\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.ock Page 7 of 12 COMcheck Software Version 3.9.2 Mechanical Compliance Certificate 2010 New York Energy Conservation Construction Code Section 1: Project Information Project Type:New Construction Project Title: New Townhouse Apartment Construction Site: Owner/Agent: Designer/Contractor. Cottage Hill Drive Schennerhom Residents)Holdings Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave 518-798-0674 Saratoga Springs,NY 12866 rich@schermerhomconstmction.com 518-580-1905 ephall@nycap.rr.com Section 2: General Information Building Location(for weather data): Warren,New York Climate Zone: 6a Section 3: Mechanical Systems List Quantity System Type B Descriptlon 1 HVAC System 1 (Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtulh Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 2(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 3(Single Zone): Heating:1 each-Central Fumace,Gas,Capacity=60 kBt th Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kStu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 4(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 5(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtulh Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 6(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtulh Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Field-Assembled DX System,Capacity=45 kBtulh,Air-Cooled Condenser Fan System: None 1 HVAC System 7(Single Zone): Project Title: New Townhouse Apartment Report date:01102/14 Data filename:Y:1Schemrerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 8 of 12 Heating:1 each-Central Furnace,Gas,Capacity=60 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 HVAC System 8(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=60 kBtulh Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser Fan System: None 1 Water Heater 1: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 2: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 3: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 4: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 5: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 6: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 7: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF 1 Water Heater 8: Electric Storage Water Heater,Capacity:40 gallons Proposed Efficiency:89.00 EF,Required Efficiency:0.88 EF Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 2 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) O 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 3 : Lj 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 4 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 5 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 6 : ❑ 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 7 : Project Title: New Townhouse Apartment Report date: 01102/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 9 of 12 ❑ 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) Lj 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Specific To: HVAC System 8 : 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) ❑ 2. Specified equipment consists of field-assembled components-efficiency documentation provided Requirements Speck To: Water Heater 1 : O 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) 2. First 8 R of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110°F for dwelling units. 4. Heat baps provided on inlet and outlet of storage tanks Requirements Speck To: Water Heater 2 : Cj 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Bluth(if>12 kW)) ❑ 2. First 8 it of outlet piping is insulated lJ 3. Hot water storage temperature controls that allow selpolnt of 90°F for non-dwelling units and 110°F for dwelling units. 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Water Heater 3 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Bluth(if>12 kW)) 2. First 8 it of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110°F for dwelling units. 4. Heat traps provided on inlet and outlet of storage tanks Requirements Speck To:Water Heater 4 : ❑ 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) ❑ 2. First 8 ft of outlet piping is insulated ❑ 3. Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110°F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To:Water Heater 5 : ❑ 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Bluth(if>12 kW)) 2. First 8 it of outlet piping is insulated ❑ 3. Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110°F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Water Heater 6 : ❑ 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btu/h(if>12 kW)) 2. First 8 ft of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110°F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Requirements Specific To: Water Heater 7 : U 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Btulh(if>12 kW)) 2. First 8 It of outlet piping is insulated 3. Hot water storage temperature controls that allow setpoint of 90'F for non-dwelling units and 110°F for dwelling units. ❑ 4. Heat traps provided on Inlet and outlet of storage tanks Requirements Specific To: Water Heater 8 : 1. Water heating equipment meets minimum efficiency requirements: Electric Water Heater efficiency: 0.88 EF(241 SL,Bluth(if>12 kW)) F-I 2. First 8 ft of outlet piping is insulated ❑ 3. Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110"F for dwelling units. ❑ 4. Heat traps provided on inlet and outlet of storage tanks Generic Requirements: Must be met by all systems to which the requirement is applicable: I] 1. Plant equipment and system capacity no greater than needed to meet loads Project Title: New Townhouse Apartment Report date: 01/02/14 Data filename:Y:1Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.ock Page 10 of 12 Exception(s): ❑ Standby equipment automatically off when primary system is operating I] Multiple units controlled to sequence operation as a function of load ❑ 2. Minimum one temperature control device per system ❑ 3. Minimum one humidity control device per installed humidification/dehumidification system ❑ 4. Load calculations per ASHRAE/ACCA Standard 183. ❑ 5. Automatic Controls:Setback to 55°F(heat)and 85°F(cool);7-day dock,2-hour occupant override,10-hour backup Exception(s): ❑ Continuously operating zones ❑ 6. Outside-air source for ventilation;system capable of reducing OSA to required minimum ❑ 7. R-5 supply and return air dud insulation in unconditioned spaces R-8 supply and return air dud insulation outside the building R-8 insulation between ducts and the building exterior when duds are part of a building assembly Exception(s): ❑ Duds located within equipment ❑ Ducts with interior and exterior temperature difference not exceeding 15°F. ❑ 8. Mechanical fasteners and sealants used to conned duds and air distribution equipment ❑ 9. Duds sealed-longitudinal seams on rigid duds;transverse seams on all duds;UL 181A or 181 B tapes and mastics ❑ 10.Hot water pipe insulation: 1.5 in.for pipes<=1.5 in.and 2 in.for pipes>1.5 in. Chilled water/refrigerant/brine pipe insulation: 1.5 in.for pipes<=1.5 in.and 1.5 in.for pipes>11.5 in. Steam pipe insulation: 1.51n.for pipes<=1.5 in.and 3 in.for pipes >1.5 in. Exception(s): ❑ Piping within HVAC equipment. ❑ Fluid temperatures between 55 and 105°F. ❑ Fluid not heated or cooled with renewable energy. ❑ Piping within room fan-coil(with AHRI440 rating)and unit ventilators(with AHRI840 rating). I] Runouts<4 it in length. ❑ 11.Operetion and maintenance manual provided to building owner ❑ 12.Thennostatic controls have 5'F deadband Exception(s): ❑ Thermostats requiring manual changeover between heating and cooling ❑ Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. ❑ 13.Balancing devices provided in accordance with IMC(2006)603.17 ❑ 14.Demand control ventilation(DCV)present for high design occupancy areas(>40 person/1000 ft2 in spaces>500 ft2)and served by systems with any one of 1)an air-side economizer,2)automatic modulating control of the outdoor air damper,or 3)a design outdoor airflow,greater than 3000 cfm. Exception(s): ❑ Systems with heat recovery. ❑ Multiple-zone systems without DDC of individual zones communicating with a central control panel. ❑ Systems with a design outdoor airflow less than 1200 dm. ❑ Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 dm. ❑ 15.Motorized,automatic shutoff dampers required on exhaust and outdoor air supply openings Exception(s): ❑ Gravity dampers acceptable in buildings<3 stories ❑ 16.Automatic controls for freeze protection systems present ❑ 17.Exhaust air heat recovery included for systems 5,000 dm or greater with more than 70%outside air fraction or specifically exempted Exception(s): ❑ Hazardous exhaust systems,commercial kitchen and clothes dryer exhaust systems that the International Mechanical Code prohibits the use of energy recovery systems. ❑ Systems serving spaces that are heated and not cooled to less than 60°F. ❑ Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. ❑ Heating systems in climates with less than 3600 HDD. ❑ Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64°F. ❑ Systems requiring dehumidification that employ energy recovery in series with the cooling coil. ❑ Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or,a separate make up air supply meeting the following makeup air requirements: Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schennerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.cck Page 11 of 12 a)at least 75 percent of exhaust flow rale,b)heated to no mora than 2°F below room setpoint temperature,c)cooled to no lower than 3`15 above room setpoint temperature,d)no humidification added,e)no simultaneous heating and cooling. Section 5: Compliance Statement Compliance Statement., The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2010 New York Energy Conservation Construction Code requirements in COMcheck Version 3.9.2 and to ply with the mandatory requirements in the Requirements Checklist. Ethan P.Hall-Architect Name-Title Signature Date Section 6: Post Construction Compliance Statement tj HVAC record drawings of the actual installation,system capacities,calibration information,and performance data for each equipment provided to the owner. F] HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. FI Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date Project Title: New Townhouse Apartment Report date:01/02/14 Data filename:Y:\Schermerhom\Cottage Hill Apartments\RJT 8-plex\Cottage Hill.ock Page 12 of 12 D CEOW MAY 0 9 2016 GRAJNY Consulting, LLC TOWN OF QUGENSBURY 69 Hayden Point Loop BUILDING & CODES Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr. Rich Schermerhorn FILE C®PY Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 93A Gentry Lane, Queensbury, NY 12804 Report Number: 0505161 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAINY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including 1"and 2"d floor= 1,408 SF - Volume of the apartment,including I�and 2"d floor= 11,876 CF Based on above, the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,297 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,297X60/11,876=6.6<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sta.w Ciraj" Stan Grainy, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 RAJNY onsulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr.Rich Schermerhorn Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 93B Gentry Lane, Queensbury, NY 12804 Report Number: 0505162 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including 1 s'and 2nd floor= 1,408 SF - Volume of the apartment,including V and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,318 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,318X60/11,876=6.7<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Slaw 47raj" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulfing, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr.Rich Schermerhorn Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 93C Gentry Lane, Queensbury, NY 12804 Report Number: 0505163 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including P'and 2nd floor= 1,408 SF - Volume of the apartment, including I"and 2"d floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,338 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,338X60/11,876=6.8<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Slaw Graj" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr. Rich Schermerhom Schermerhom Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 93D Gentry Lane, Queensbury, NY 12804 Report Number: 0505164 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including 1"and 21 floor= 1,408 SF - Volume of the apartment, including 11 and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,376 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,376X60/11,876=6.9<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfaw(i raj" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 LRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr. Rich Schermerhorn Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 93E Gentry Lane, Queensbury, NY 12804 Report Number: 0505165 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including I"and 2nd floor= 1,408 SF - Volume of the apartment,including I'and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,282 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,282X60/11,876=6.5<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Stow GrA4" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr.Rich Schermerhom Schermerhorn Real Estate Holdings 536 Bay Road Ste.2 Queensbury,NY 12804 Inspection Address: 93F Gentry Lane, Queensbury, NY 12804 Report Number: 0505166 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAINY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including I"and 211 floor= 1,408 SF - Volume of the apartment,including 1"and 21 floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,272 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,272X60/11,876=6.4<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- 1%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, S{aw Grajr,.y Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 RAJNY onsulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr.Rich Schermerhom Schermerhorn Real Estate Holdings 536 Bay Road Ste. 2 Queensbury,NY 12804 Inspection Address: 93G Gentry Lane, Queensbury, NY 12804 Report Number: 0505167 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAJNY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment,including 1"and 2'floor= 1,408 SF - Volume of the apartment,including 1"and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,370 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,370X60/11,876=6.9<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company.We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfau Grafi" Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulting, LLC 69 Hayden Point Loop Diamond Point, NY 12824 518 221-3240 05/05/2016 Mr.Rich Schermerhorn Schermerhorn Real Estate Holdings 536 Bay Road Ste. 2 Queensbury,NY 12804 Inspection Address: 93H Gentry Lane, Queensbury, NY 12804 Report Number: 0505168 Dear Rich: At your request, the Blower Door Inspection to verify infiltration rate of the subject property, as per requirements of the NYS 2010 Energy Conservation Construction Code was performed on 05/05/2016. GRAINY Consulting, LLC is pleased to submit the following report. The following data was provided: - Square Footage of the apartment, including I"and 2'floor= 1,408 SF - Volume of the apartment,including 1"and 2nd floor= 11,876 CF Based on above,the following test data was collected: - Infiltration Rate of the apartment at 50 Pascal= 1,171 CFM - ACH50,Actual Changes per Hour at 50 Pascal= 1,171X60/11,876=5.9<7 The Instruments used for test were provided by the Energy Conservatory Digital Gauge DG-3 rated accuracy=+/- I%,calibrated minimum once per year. Thank you for selecting our company. We appreciate the opportunity to be of service. Please call this office if there are any questions. Sincerely, Sfu Grcjr,y Stan Grajny, PE RESNET HERS Energy Rater 5609922 NYS PE 065406-1 GRAJNY Consulting, LLC. 69 Hayden Point Loop Diamond Point, NY 12824 Invoice REPORT NO.: 0505160 INSPECTION DATE: 05/05/16 PREPARED FOR: Mr. Rich Schermerhorn Schermerhorn Real Estate Holdings 536 Bay Road Ste. 2 Queensbury, NY 12804 PROPERTYINSPECTED: 93 Gentry Lane—8 Apartments Queensbury, NY 12804 Description Amount 93 Gentry-8 Apartments. — Blower Door Test, Report and Inspection 600 Plan Review & Improvement Analysis & Site Visit Site Visit, Insulation and Thermal Bypass Inspection Site Testing Blow Door, Duct Blasting, CAZ & Inspection) Provider Fee (Cost) TOTAL $ 600 Thank you for your business Payment of this invoice is due upon receipt. The late payment charge rate of interest is 1.5%monthly(18.0%per annum), after 30 days TOWN OF QUEENSBURY FIRE MARSHAL IFI*1 742 Bay Road, Queensbury, NY. 12804-5902 761-8205 / 761-8206 Fax: 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the installation manual accompanying the appliance. No deviation from the manufacturer's instructions or specifications is allowed. Permit#: Name: Inspection Date: Address: 93 Time: Inspector: Rough-in/Final: Appliance Manufacturer: Model#: Direct Vent Factory Built Chimney _Flue Size Double Wall _Triple Wall _Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles(all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearance to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-off Valve Combustion Air Hearth Extension (if any) Mantel-height above f/p opening Witness Operation Tank Placement(if LP) CO Detection CSST Bonding White-Building Department Yellow-Customer Pink-Fire Marshal Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 Table 7:Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors male c«n.r outside corner Recessed Location See Table 6_8 Ni—P—I/ Gr / ��'�, �! /„/� 1-1 �r��/ losfzee.d CI Ope.bl FlxetlB—O 7/ \\1 Balcony with No BWe Wall Balcony with Perpendicular Side wan G Closed Ill , Op B enable F �_ B • s. El TERMINATION CAP O AIR SUPPLY INLET IN GAS METER Q RESTRICTED AREA 1 (TERMINATION PROHIBITED) U.S.Installation** Canadian Installation* A Clearance above grade,veranda,porch,desk,or balcony 12"(300 mm)** 12"(300 mm)* B Clearance to window or door that may be opened • 6"(150 mm) 6"(150 mm) for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW),and<50,000 Btu/h for fireplaces>10,000 Btu/h(3 kW) (15 kW), 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** C Clearance to permanently closed window • 9"(229 mm) 12"(305 mm) recommended to prevent window condensation recommended to prevent window condensation D Vertical clearance to ventilated soffit located above the 1• 8"(458 mm) 18"(458 mm) termination within a horizontal distance of 18"(458 mm) E Clearance to unventilated soffit 12"(305 mm) 12"(305 mm) ` F Clearance to outside corner 5"(127 mm) 5"(127 mm) minimum minimum G Clearance to inside corner • 6"(152 mm)minimum 6"(152 mm)minimum H Clearance to each inside of center line extended above 36"(910 mm) 36"(910 mm) meter/regulator assembly within a height of 15 ft above the meter/regulator assembly** within a height of 15 ft above the meter/ regulator assembly* I Clearance to service regulator vent outlet 36"(910 mm)** 36"(910 mm)* J Clearance to nonmechanical air supply inlet to building or 6"(150 mm) 6"(150 mm) the combustion air inlet to any other fireplace for fireplaces<10,000 Btu/h(3 kW), for fireplaces<10,000 Btu/h(3 kW), 9"(230 mm) 12"(300 mm) for fireplaces>10,000 Btu/h(3 kW)and<50,000 Btu/h(15 kW), for fireplaces>10,000 Btu/h(3 kW) 12"(300 mm) for fireplaces>50,000 Btu/h(15 kW)** K Clearance to a mechanical air supply inlet 36"(910 mm)above if within 10 ft(3 m)horizontally** 72"(1830 mm)* L Clearance above paved sidewalk or paved diveway located 84"(2130 mm)f 84"(2130 mm)t on public property M Clearance under veranda,porch,deck or balcony 12"(300 mm)*$ 12"(300 mm)*$ N Depth of alcove(maximum) 72"(1830 mm)** 72"(1830 mm)* 0 Clearance to termination(alcove) 6"(15.2 mm)** 6"(15.2 mm)* P Width of alcove(minimum) 36"(910 mm)** 36"(910 mm)* Q Clearance to combustible above(alcove) 18"(457 mm)** 18"(457 mm)* * In accordance with the current CSA-B149.1 National Gas And Propane Installation Code ** In accordance with the curent ANSI Z223.1/NFPA 54 National Fuel Gas Codes $ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings *$ Only permitted if veranda,porch,deck,or balcony is fully-open on a minimum two sides beneath the floor 13 Innovative Hearth Products Installation Superior'M DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8),with the following exception:The unit may not be recessed (allowance made for mantel legs/side trim in Figure 6). When the unit is installed with one side flush with a wall,the wall on the other side of the unit must not extend beyond the front edge of the unit(Figure 6). Table 8:Minimum Clearances * 1"(26mm)to wrapper for 45"model,all Back others 1/2"(13mm)to wrapper 0"(0 mm)to Spacers Sides 1/2"(13 mm)to wrapper 0"(0 mm)to Spacers** Top Standoffs 0"(0 mm)to top standoffs Floor 0"(0 mm) From Bottom of Unit to Ceiling 64"(1626 mm) Vent 3"(76 mm)—Top**** 1"(25.4 mm)—Sides and Bottom Front Service Clearance— 36"(914 mm) clearance immediately in front of viewing area(s) *3"(76 mm)above any horizontal/inclined vent component. **See Page 19 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. ***Top vent clearance can be reduced to 2"on horizontal runs when first elbow is located at least 6 ft above the fireplace. The fireplace must be mounted on a fully supported base extending the full width and depth of the unit.The fireplace may be located on or near conventional construction materials. However, if installed on combustible materials,such as carpeting, vinyl tile or other combustible material other than wood flooring,the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Hearth Extension A hearth extension is not required with this fireplace. If a hearth extension is used, do not block the lower control compartment door.Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements. Shelf Height To provide for the lowest possible shelf surface, use the rear vent model. For top vent models,the venting attached to the top vent should be routed in a way to minimize obstructions to the space above the fireplace. Do not insulate the space between the fireplace and the area above it (Table 9and Table 10).The minimum height from the base of the fireplace to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Table 9 and Table 10. Table 9:Combustible Shelf Height—Top Vent Top Vent with one 90°Elbow Model Secure Vent® Secure Flex@(flex elbow) DRC2033/DRT2033 44"(1118 mm) 46"(1168 mm) DRC2035/DRT2035 47"(1194 mm) 49"(1245 mm) 7 i DRC2040/DRT2040 52"(1321 mm) 54"(1372 mm) pA-ffig No ow combustibles or Shelf Heightinsulation or DRC2045/DRT2045 50"(1270 mm) 52"(1321 mm) (see table) in the shaded area between the appliance and the shelf above it. mininimminot 14 Innovative Hearth Products Installation SuperiorTM DRT2000 and DRC2000 Direct-Vent Gas Fireplaces 900004-00,04/2015 Table 10:Combustible Shelf Height—Rear Vent Rear Vent with two 90°Elbows Model >_3"clearance from shelf to Secure Vent® Secure Flex®(flex elbow) top of fireplace and/or vent DRC2033/DRT2033 34"(864 mm) 34"(864 mm) pipe,whichever is higher DRC2035/DRT2035 351/2"(902 mm) 351/2"(902 mm) I `41.1115 DRC2040/DRT2040 401/2"(1029 mm) 401/2"(1029 mm) '%e combustibles Shelf Height DRC2045/DRT2045 45 1/2" 1156 mm 451/2" 1156 mm (see table or insulation ( ) ( ) ) 0 in the shaded iarea between A the appliance and the shelf above it. Figure 6:Combustible Side Clearances Figure 7:Mantel Height At 6"minimum side wall clearance,a F.--Mantel depth combustible Top View of 18(457) wall can project Fireplace to any length. 16(406) 1 • 4• 5° Combustible materials 14(356) 11 31/2° allowed in shaded area ,L -- (89 mm) "Safe Zone". 12(305) • ----r. Combustible walls 10(254) shown in dark gray : : 8(203) :----- - ---- Combustible mantel legs may project 12 8 q --- - - ---- beyond either side of (3051 (203) + (102) Hood - - the fireplace opening 10 6 2 _ _ as long as they are kept (m• in. m) (25a) (152) (51) ni_ within the shaded area illustrated here. Fireplace 6" (152 mm) Wall Finishes/Surrounds/Mantels NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the fireplace front face (black sheet metal).Never allow combustible materials to be positioned in front of or overlapping the fireplace face(Figure 41). Non-combustible materials,such as surrounds and other fireplace trim,may be installed on the fireplace face,but they must not cover any portion of the removable glass panel or control compartment. Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels constructed of non-combustible materials may be installed at any height above the fireplace opening. However,do not allow anything to hang below the fireplace hood. Minimum clearance requirements include any projections such as shelves,window sills, mantels,etc.above the fireplace. NOTE:To avoid heat-related finish damage,use finish materials rated 175°F,or higher,on the underside of the mantel. INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace, follow these steps: 1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction). 2. Remove the shipping pad, exposing the front glass door. 3. Remove the glass door(Page 57). NOTE: Place the glass door on the shipping carton to protect its surface. 15 g .. t _t a : +, it 'a, Town of Queensbury-Building and Codes-Fire Marshal 742 Bay Road-(518)761-8256 Building(518)761-8206 Fire Marshal Case Number: CC-000436-2015 Case Module: Permit Inspection Date: 05/13/2016 Inspection Status: Passed Inspector: Gary Stillman Inspection Type: Gas Fireplace/Stove Job Address: 93 GENTRY LN Parcel Number: 296.15-1-2 Queensbury,NY 12804 Contact Type Company Name Name Primary Owner [Schemerhorn Properties] Applicant [Schermerhorn Properties] Granted Permission [Schermerhorn Properties] Contractor Schermerhorn,Richard Checklist Item Passed Comments Clearances to Combustibles(all sides) -Clearances to CombustiblesYES (all sides) Witness Operation-Witness Operation YES Vent Clearance to Combustibles-Vent Clearance to Combustibles YES Hearth Extension(if any)-Hearth Extension(if any) YES Vent Chimney Termination -Vent Chimney Termination YES General Comments-General Comments YES Superior Fireplace,model DRT2033TMN 8 fireplaces in units A-H Gas Shut-off Valve-Gas Shut-off Valve YES Combustion Air-Combustion Air YES CO Detection-CO Detection YES Verified and tested Floor Protection-Floor Protection YES Mantel-height above fp opening-Mantel-height above fp opening YES CSST Bonding-CSST Bonding YES Firestop(s)-Wall Penetration -Firestop(s-Wall Penetration YES Building Inspection notes-Building Inspection Notes YES Ok for CO,Fire Marshal final Firestop(s)-Vertical Chase -Firestop(s)-Vertical Chase YES Stillman,Gary(Inspector) May 13,2016 Page(6) { Clearances: UNIT 1" back %z" side 0 Top 0 floor VENT 3"Top 1" side/back Serial Numbers: Unit A � � 9 b (01 Unit B ,1 i 6 IN ?,0 UnitC Al CA- ?D Lidaq Unit D A,5A 2.0 Unit E /SAX) tP " UnitF /\ IcA (o Go?y UnitG � dU W.11 Unit H 15 1\30 1d.\3 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit ............... ............Cert. N2 42980 Cut-in Card No..................................... Owner...........2! &74 1-4,6pA.� j:3 g-(P P,S........... .............................. Location.....1.�.... ....................................................... Installation Consisting of ....W...../.?'G........... ,.2V6026-Z'--f-� /1ZZ-1qa-'S ........................... ........................................ ge-lt?Es .............................. Installed By..... ...........................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making i7p—e 'ons at any time, and if its rules are violated,the Company shall have the right t;re o.. ...��efi ...... ..... .... ...... . ........... Date..... ...................................... INSPECTOR.... ..................... Member N.F.P.A.,I.A.El. Rough Plumbing I Insulation Inspection Report Inspection request received Z ( 5 Name Inspected on I Z Location (� L t\), Arrive :E a ,pm Permit No. Inspector's Initials Type of Structure COMMENTS Y N NA Plumbing under slab Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place I Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air /Head _ 50 P.S.I for 15 minutes ? 0 7j W It`lDot35 nsulation /Residential Check/Commercial Check F Window Sealing �l AWES t E�e��EV Tyvek or Similar Exterior Sealant Proper Vent.Attic Vent Door/Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly /No duct tape Blower Door Test Air Sealing Town of Queensbury Building & Code Enforcement Office No.(518)761-8256 Town of 4ueensbury Building &Code Enforcement Office No. (518)761-8256 Framing 1 Firestopping Inspection Report Inspection request received: Name: Inspected on: Location: Arrive: a.m.t( .mJ Permit No.: Z� Inspector's Initials: ��--- TYPE OF STRUCTURE: Y _ NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specifirafion Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w)16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%:inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report C RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall r,5� 627 Maple Avenue FJG` Saratoga Springs NY 12866 Voice 518 5801905 Fax 518 584 5012 Email ephall@nycap.rr.com Special Inspection Report To: John O'Brien -Town of Queensbury—Code Enforcement Officer From: Ethan Hall Date: 14 September, 2015 Re: Schermerhorn Residential Properties—Cottage Hill Townhouse Apartments— Building #7 At the above referenced project location this office performed on site observations of the shear wall installations prior to insulation. All items appear to be installed in accordance with the construction drawings. If there are any questions please contact our office. Regards, RgD ur YEE Ethan . Hall—Architect Rucinski Hall Architecture , J 70J6N r YASchennerhornTonage Hill Apartmcnts\Papcmork\Special Inspection Letter•Rldg 7-14 Sept 2015.doc 1 Town of Queensbury Building&Code Enforcement —F Lk tzs Office No. (518)761-8256 l 3 Rough Plumbing I Insulation Inspection Report Inspection request received: q 11 ICE::, _ 1 Name: k�irvruyh�r�v� Inspected on: t Location: i C{}j Arrive: a. p.m. Permit No.: 23 Inspector's Initials: Type of Structure: /COMMENTS Z� Y N NA 361— t5 I Plumbing under slab Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check ommercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/Insulation Inspection Report Town of Queensbury Building&Code Enforcement -TV-:s Office No.(518)761-8256 10- 12, Rough Plumbing I Insulation Inspection Report Inspection request received: Name: Inspected on: �'1 Ila% Location: 3 _ Arrive: 1D, M. Permit No.: _�2� Inspector's Initials: Type of Structure: COMMENTS Y N NA Plumbing under slab ' Rough Plumbing/Nail Plates 1 Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I.or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/ mercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape Blower Door Test Air Sealing Rough Plumbing/Insulation Inspection Report Rough Plumbing / Insulation Inspection Repo t Office No. (518) 761-8256 Date Inspection re est r ed: Queensbury Building & Code Enforcement Arrive: / . a 742 Bay Road, Queensbury, NY Jj12804 Inspector's Initial NAME: �M 1—Gtirs�'ti PERMIT LOCATION: 6 . til SPECT ON: TYPE OF STRUCTURE: ru Y N N/A Plumbing under slab Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place C`r 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum �/ t Cleanout every 100 feet/change of direction l0 Pressure Test Drain /Vent Air/Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head for 15 minutes Insulatio idential Check/ C mmercial Check Window Sealing OL •?c Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing—Insulation Inspection-02 0513 Town of Queensbury Building & Code Enforcement t` c N Office No. (518)761-8256 &1c Framing / Firestopping Inspection Report Inspection request received: 0 2_t)tw_15 Name: JCXyyMa YVVC uVn Inspected on: (a 2 Location: GH' -0-11. q5 C-kC Arrive: m. Permit No.: t� 4t,2_2> Inspector's Initials: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs 1 Headers 13 Truss Specification Provided Bracing I Bridging Joist hangers Jack Posts I Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches I Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %:(w)16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour Z ire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 518 inch Type X Garage side 518 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report Town of Queensbury Building&Code Enforcement -V;V4 Office No.(518)761-8256 i3,,to Rough Plumbing I Insulation Inspection Report Inspection request received: 11�1-2-OA 5 1 Name: Sc�Q..yrY� V-%Qv 1 Inspected on: 251 2,Ot Location: &+4rtCv Va l� 6WN.i� Arrive: rzvc M. Permit No.: 2 3 Inspector's Initials: Type of Structure: o - COMMENTS Y N NA Plumbing under slab Rough Plumbing I Nail Plates Plumbing Vent I Vents in Place 1 '%inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet I change of direction Pressure Test Dr ' /V t tl P r 10 ft. above highest connection for 15 minutes ressure Test / W ftationuloResidc Sply Piping r 15 minutes ntial Check I Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed (No Insulation) Duct I Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly I No duct tape Blower Door Test Air Sealing Rough Plumbing I Insulation Inspection Report Town of Queensbury Building & Code Enforcement Office No. (518) 761-8256 Framing 1 Firestopping Inspection Report Inspection request received: Name: CHER EO Inspected on: —1 —1ZI Location: -11– f�7 cO G E1LWE-Arrive: Permit No.: t , – L X73 Inspector's Initials: TYPE OF STRUCTURE: 1, ,V\C)u6E,,. Y N NIA COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs I Headers Truss Specification Provided Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed propedy 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Extedor Deck Bracing Headroom 6 ft.8 in. Notches/Holes I Bearing Walls Metal Strapping for Notches Top Plate 1 %(w)16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft or less on center Ace and water shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%2 inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above I below grade 5.0 sf grade Design Professional Sign-off,if required Framing I Firestopping Inspection Report Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Insp ection Queensbury Building &Code Enforcement Arrive:742 Bay Road, Queensbury, NY 12804 InspectNAME: i_Nr�M�RN�S�- LOCATION: R I _D(C, 7 9.3 CBNTRY ArJF INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/chan a of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes \A insulation Insulation /Residential Check/Commercial Ch Tyyek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: Rough Plumbing Insulation ReporLrevtsed Nov 17 2003, revised February 15,2005, revised January 7, 2008 Town of Queensbury Building & Code Enforcement Office No. (518)761-8256 Framing / Firestopping Inspection Report Inspection request received: Name: I cS�i�(1 PJZJvnp �,� Inspected on: Location: 3 Arrive: a.m.Do.m. Permit No.: t 3 Inspector's Initials: TYPE OF STRUCTURE: ci Q id Y N N/A COMMENTS: Framing Attic Access 22"x 30"minimum Jack Studs/Headers Truss Specification Provided Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft.8 in. Stairwells 36 in.or more Exterior Deck Bracing Headroom 6 ft.8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8)16D nails each side Draft stopping 1,000 sq.ft.floor trusses 01 Anchor Bolts 6 ft,or less on center nd.watershleld 24 jpches from wall Fire separation 1,2,3 hour Fire wall 2,3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Y:inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade Design Professional Sign-off,if required Framing/Firestopping Inspection Report mD� L Foundation Inspection Report 3 Office No. (518) 761-8256 LInspector's tion reques ec ' ed: Queensbury Building&Code Enforcement — epart: a m 742 Bay Rd.,Queensbury, NY 12804 Initials• 1� NAME: RMIT#: 7 — r 3 LOCATION: 3 INSPECT ON: TYPE OF STRUCTURE: s Comments a Y N N/A Footings iers Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: I inch width inches above footing 6 mil poly for we Backfill Approval Plumbing Under Slab P C/Cast/Copper ndation Insulatio I terio erior R gh Grade 6 inc drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM ) Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins ection re r Iu d: Queensbury Building & Code Enforcement Arrive: Q 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: S C11n L61 . 'D PERMIT . l 4,1-`,/c.3 LOCATION: INSPECT TYPE OF STRUCTURE: Y N N/A ough Plumbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test in ent d �ure or 10 ft. above highest connection for 15 minutes Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing insulation Inspection-02 0513 3 O Foundation Inspection Report �_ Office No.(518)761-8256 Date Inspection requ ive Queensbury Building&Code Enforcement Arrive: °o am/ m Depart: : pm 742 Bay Rd., Queensbury, (NY 12804 rr Inspector's Initials: NAME: SGV\.Cr✓�'� P`C't I\j ERMIT#: J Z3 LOCATION: INSPECT ON: I l7 0G TYPE OF STRUCTURE: gL) 9'77 Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width �� 6 inches above footing 6 mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulati n Inr , terior R_ VD . Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM l`(1 )06kaq-11 Foundation Inspection Report Office No.(518)761-8256 Date Ins ectio r st re rve Queensbury Building&Code Enforcement Arrive: m Depart: a m 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial NAME: C� �e2r Mg'r f'wy n MIT#: LOCATION: /3 6r PJ+r- U INSPECT ON: TYPE OF STRUCTURE: �7 z � � Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. \ Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Doting Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab (�rnn'r Backfill Approval ��Ra Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building &Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM (J'n d /b -/a Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial . c NAME: PERMIT#: _d �f—yw 3 LOCATION: +r INSPECT ON: TYPE OF STRUCTURE: O� �9LO � a g Comments � ld � '77 Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place �j v Foundation Dampproofing Y /� Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: C 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM C) - 1 Foundation Inspection Report / Office No.(518) 761-8256 Date Inspection request received: I tl y Queensbury Building&Code Enforcement Arrive: 4Lam/pm Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: 5��,, L� t I, !,(Yc� PERMIT#: LOCATION: INSPECT ON: O TYPE OF STRUCT�^ (/� L © Commcnk Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM C (01 ��! , [ u 1Z Foundation Inspection Report N Office No. (518) 761-8256 Date Inspection request received: /U 2 I Queensbury Building&Code Enforcement Arrive: r/W am/ Depart: am/pm !Dk742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: a/� PERMIT#: LOCATION: INSPECT ON: a U I TYPE OF STRUCTURE: 61 W 4 "T' Comments Y N N/A Footings 1 Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/18/2013 2:44:00 PM Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: f7� NAME: PERMIT#: LOCATION: 93 C INSPECT ON: i z• 7 TYPE OF STRUCTURE: Comments Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. 7Cd4 F �� Materials for this se on site. � Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski >� Ethan Peter Hall 627 Maple Avenue �JG Saratoga Springs NY 12866 Voice 518 580 1905 Fax 518 584 5012 Email ephall@nycap.rr.com Transmittal To: Dave Hatin —Town of Queensbury— Code Enforcement Officer 10 2014 From: Ethan Hall Date: 10 September, 2014 Re: Schermerhorn Cottage Hill Bldg. #7—8 unit Townhouse apartment building Attached are two (2) reduced scale copies of the building plans for the 8 unit Townhouse apartment building #6 Gentry Lane, building permit application, Com-Check Energy Code Compliance, building structural calculations and the contract between Schermerhorn Construction and Grajny Consulting LLC for the blower door test for the units. This is a 8 unit townhouse apartment building for which a full size set of building plans was previously submitted for Building #8 Gentry Lane If there are any questions please let me know. YASehemerhom\Cottage Hill Apartments\Paperwork\Transmittal-4 10 Sept 2014.doe 1