RC-000036-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000036-2016 Date Issued: Monday, March 27,2017 This is to certify that work requested to be done as shown by Permit Number RC-000036-2016 has been completed. Tax Map Number: 240.6-1-15 Location: 33 HANNEFORD RD Owner: KIM HANSON,Bruce Hanson Applicant: Bruce Hanson This structure may be occupied as a: Single Family Dwelling(rebuild) 1006 s.f. Permit renewal (invoice#253)through 9/24/2016 By Order of Town Board TOWN OF QUEEN/SBURpY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, QvjF V Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. - _ TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761.8201 Ism Community Development-Building&Codes (518)761-8256 BUILDING PERMIITT Permit Number: RC-000036-2016 EV ISE Tax Map No: 240.6-1-15 Permission is hereby granted to: Bruce Hanson For property located at: 33 HANNEFORD RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Bruce Hanson Single Family-New $19,700.00 Owner Address: 134 Spring Hill RD Total Value $19,700.00 Harwinton,CT 06791 Contractor or Builder's Name/Address Electrical Inspection Agency RENEWED Plans&Specifications Single Family Dwelling(rebuild)1006 s.f. i PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,September 24,2016 (If a longer period is required,an application for an extension most be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) / Dated at the To of Qu sbury; ptember 24,2004 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement /Jo 7a Building Permit Application Town of Qw=bmy—Dept of Commtmity DevelopMe4 742 Bay Road,Que`=bury,NY C() (516)761.8256 APOrnnNOinn9itmnst M1.10madboforebegidmtha TOOCve'la PormitFileNo. o Noditiltionwillb0madspptil *1vpItheronthi3 da Foo Paid validbmlding permit. All applicants'costes on this Application.must be ocmpleted end must appear on the Rt4.Fee Paid S applioatlov.form. / Rovlowod 13F.Applioamtr r Jc 'e /G�, ale,le,kI J t1 owner, Addrosa: Addreea: Phouo#(EU)S�FL- x363 Phone#(_) PrOPIO yIAmtion: Lot Ntmtbar-. ! House Number 331 - SabdivitdonName: Tax Map Ntunbtrr 2yO, d 6—!— (S NC9 $ r\ 1a1 '$sthm Iviarket Valve of conSturtton:$ Addition: '"""" If an Addition what will use of now additionbe? No ampwanton! Qtbor work a�ad: '�/' �� 0c=P ncg7nfor=tion V Noor 2 Noor dthar noor T W eq.it sq.ft. sq,ft. Sgaare boot Two dwemn o Townhouse o dw #ofunits t7 OS�CO II 1KQn0anLl1D O O 1 44 detachod A 2 oar detached a 3 car ddadh¢d C1 Iour xdxched a 2 oar xttoohed ��—�—M 0 3 mir atdtched o StompbuUdmg. oo ni II Stomp building- ra ddentlsl 9 What is the proposed height of the atruetar4—_foot inches •9vM e'y second-hand or tmgradod lumber be used? If so,forwhat? /1/0 Type of Heating Systom electric/ oil ! gas/'Wood w /forced hot air/baseboard!other 4� Ntrmbdr of iq be iusjalled 1Y+sf of ------.�1 �Y4flTF2Y6t to be inateiled -� List below the persons)responsible for supervision of work as regards to budding codes: Nar'r Address Photo Nvmbor Builder nno_n %<rs 7Nc, �s]70 _k root' . ZG -Lrgy Plmnber 1H1R60n ---�� Elocmcralr /t lir plemo signbolow aftor you have cetofayroad the Statomeat To the best ofmy knowl0dF the strtements coutsiaod in thio application,together with the plain and speoiBcaCon, sobmluod,are a true sad oomplote statement of all Proposed work to be d000 on the dac4nd es�d Providona of tho Bulldi¢g Coco,&a Zoning ordivano0 and all other lam ptam3s thak sll with.whetber ocitledorne P ng tothopropwodWork641becomp cd oP rod aadtbat sueh wink h atnhorizedtry the owns. Pmthar,it is understood tl=Vwe Shall mAwai%t+dttthlicPuatot or Director � = of QOrtificate of Compllanoo baing"Shod of roquwted by tho Zonta of and Cocos an g laeatlon of all new olioY �S'arvev by a licensed aurveyar;drnwnto ecalo,showing actual Sisaatwc: owner,owner's agent,architect,conhactor /,Jvllc� n.tar, sollo' e Z00/ZOO In Tod OT:00 (MA t00Z/9T/Z0 Fire Marshal's Office Town of Queensbwy,742 nay Road,Queensbury, NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances Date_`/ <9 20 �� Permit No. O Application is hereby made to the Building& Codes Office for the issuance of a Building and Usti Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perforin required inspections. - NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information /, (circle appropriate words) Name: kr r�r '+Ci c4/1 Stove: wood coal pellet fas / Fireplace insert Address: ylnf) cr Fireplace, factory-built: woody gas bi'v t / — FirepL? r}tasonry' woo4) gas Furnace: wood gas oil Phone: t?6 0 -- S43 - /3l If non-masonary applicance, please provide Owner: "" Manufacturer Name: Address: �4 %f;Y !�' Model Number: Chimney Information Phone: (circle appropriate wor�d�"_ Masonry ck brick4sG;P-y � / `� Flue til steel size: % 7�%y5rzches Exact Address: �3 /7Grt/J e f rr� /f� of construction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double wall / Triple wall / Insulated / Direct venting Chimney Liner Gaaliier'a DBpss-L�:aciut—Tonga of Queen abuzy,lVe�Yorlr Fire Marshal Code 0 S Collected S fle ianler! Receivedfroya(refunded tci). r ) � address: __--- A l73 3389 (190) Public Safety Q` - A 133 2635 (230)trbllnor•Sales DATE: �•y.�+?.wo— Town. Gl�e%o�. Dy,,.,�y, White(Applicant) / Green(Fire Marshal) ! Yellow(Bldg. Dept.) ) Pink R Goldenrod(Cashier's Dept.) Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code RES checkSoftware Version 3.6 Release 1 Data filename:C:\Program Files\Check\REScheck\draft-no u's.rck PROJECT TITLE:BRUCE&KIM HANSON COUNTY: Warren STATE:New York HDD:7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE:Non-Electric WINDOW/WALL RATIO:0.20 DATE:09/07/04 DATE OF PLANS: 09/02/04 PROJECT DESCRIPTION: REPLACE EXISTING WALLS AND ROOF DES IGNER/CONTRACTOR: BRUCE&KIM HANSON PROJECT DOTES: 33 HANNEFORD RD. QUEENSBURY,NY COMPLIANCE: Passes Maximum UA= 194 Your Home UA= 192 1.0%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Plc rI Ceiling L•Cathedral Ceiling(no attic) 420 30.0 0.0 14 Ceiling 2:Flat Ceiling or Scissor Truss 687 30.0 0.0 24 N — Wal1 1: Wood Frame, 16"o.c. 244 19.0 0.0 12 j� Window 1: Wood Frame:Double Pane with Low-E 48 0.280 13 W- Wall 2: Wood Frame, 16"o.c. 264 19.0 0.0 9 ` - Window 2: Wood Frame:Double Pane with Low-E 48 0.280 13 Window 3: Wood Frame:Double Pane with Low-E 17 0.280 5 - Window 4: Wood Frame:Double Pane with Low-E 5 0.280 1 - Window 5: Wood Frame:Double Pane with Low-E 5 0.280 1 1 d --Window 6: Wood Frame:Double Pane with Low-E 5 0.280 1 j - Door 1:Glass 42 0.289 12 S —Wall 3: Wood Frame, 16" o.c. 244 19.0 0.0 14 —Window 7: Wood Frame:Double Pane with Low-E 4 0.280 1 J —Window 8: Wood Frame:Double Pane with Low-E 4 0.280 1 F —Wall 4: Wood Frame, 16" o.c. 264 19.0 0.0 12 —Window 9: Wood Frame:Double Pane with Low-E 6 0.280 2 — Window 10: Wood Frame:Double Pane with Low-E 6 0.280 2 —Window 11: Wood Frame:Double Pane with Low-E 5 0.280 1 1 — Window 12: Wood Frame:Double Pane with Low-E 5 0.280 1 ? —Window 13:Wood Frame:Double Pane with Low-E 5 0.280 1 —Door 2:Solid 44 0.230 IO Floor l: All-Wood Joist/Truss:Over Unconditioned Space 1006 22.0 0.0 42 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer�4/ �/ Date V n ~ REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoltware Version 3.6 Release I DATE:09/07/04 PROJECT TITLE:BRUCE&KIM HANSON Bldg. Dept. Use I Ceilings: [ ] I L Ceiling 1:Cathedral Ceiling(no attic),R-30.0 cavity insulation I Comments: [ ] 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments:_ I [ Above-Grade Walls: [ ] I 1. Wall 1:Wood Frame, 16" o.c.,R-19.0 cavity insulation I Comments: [ ] I 2. Wall 2: Wood Frame, 16"o.c., R-19.0 cavity insulation I Comments: [ ] I 3. Wall 3: Wood Frame, 16" o.c.,R-19.0 cavity insulation I Comments: ( ] I 4. Wall 4: Wood Frame, 16"o.c.,R-19.0 cavity insulation I Comments: I Windows: [ ] 1. Window 1: Wood Frame:Double Pane with Low-E, U-factor:0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ]Yes[ ] No I Comments: [ ] I 2. Window 2: Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ]Yes[ ]No [ Comments: [ ] I 3. Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors, describe features: #Panes_Frame Type Thermal Break?[ ]Yes [ ]No I Comments: [ ] I 4. Window 4: Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ] Yes [ ]No I Comments: [ J I 5. Window 5: Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break?[ ]Yes[ ]No I Comments: [ ] I 6. Window 6: Wood Frame:Double Pane with Low-E, U-factor:0.280 For windows without labeled U-factors, describe features: 1 # Panes_Frame Type Thermal Break? [ ] Yes [ )No I Comments: [ ] 1 7. Window 7: Wood Frame:Double Pane with Low-F., U-factor:0.280 For windows without labeled U-factors,describe features: # Panes_Frame Type _ _Thermal Break? [ ] Yes[ ]No 1 Comments: [ ] 1 8. Window 8: Wood Frame:Double Pane with Low-E,IJ-factor: 0.280 For windows without labeled U-factors,describe features: # Panes_Frame TypeThermal Break? [ ] Yes( ] No 1 Comments: [ ] 1 9. Window 9: Wood Frame:Double Pane with Low-E, U-factor: 0.280 1 For windows without labeled U-factors,describe features: 1 #Panes_Frame Type Thermal Break? [ ] Yes[ ]No 1 Comments: [ ] 1 10. Window 10:Wood Frame:Double Pane with Low-E, U-factor:0.280 1 For windows without labeled U-factors,describe features: #Panes_Frame Type Thermal Break? [ ] Yes[ ]No 1 Comments: [ ) 1 11. Window 11:Wood Frame:Double Pane with Low-E, U-factor:0.280 1 For windows without labeled U-factors,describe features: 1 #Panes_Frame Type Thermal Break? [ ] Yes[ ] No Comments: [ ] 1 12. Window 12: Wood Frame:Double Pane with Low-E, U-factor:0.280 1 For windows without labeled U-factors,describe features: 1 #Panes_Frame Type Thermal Break?[ ] Yes [ ] No 1 Comments: [ ] 1 13. Window 13:Wood Frame:Double Pane with Low-E, U-factor:0.280 For windows without labeled U-factors,describe features: 1 #Panes_ Frame Type Thermal Break? [ ] Yes [ ]No 1 Comments: I 1 Doors: [ ] 1 1. Door I: Glass, U-factor:0.280 Comments: [ ] ] 2. Door 2: Solid,U-factor:0.230 1 Comments: I Floors: [ ] 1 1. Floor I: All-Wood Joist/Truss:Over Unconditioned Space,R-22.0 cavity insulation 1 Comments: I 1 Air Leakage: [ ] 1 Joints,penetrations,and all other such openings in the building envelope that are sources of air 1 leakage must be sealed. [ ] I Recessed lights must be I)Type 1C rated,or 2)installed inside an appropriate air-tight assembly 1 with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 1 3" clearance from insulation. I Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls,and floors. I Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ( ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-t 1. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R- ( ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181 A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g.(500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ j Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code ojNew York State,the Residential Code ojNew York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Mininunn Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(Fl U t�o J" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Mininrunr Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ran e F 2"Runouts 1"and Less 1.25" to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 LO 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Windows Mark Unit Dimension Unit Code/ Item Size Remarks 1 2'-1 5/8 x 3'-0 7/8 WDH20210 Andersen 2 2'-1 5/8 x T-0 7/8 WDH20210 Andersen 3 2'-4 3/8 x F-8 1/2 AN251 Andersen 4 2'-4 3/8 x F-8 1/2 AN251 Andersen 5 3'-5 5/8 x 4'-8 7/8 WDH3446 Andersen 6 9'-10 13/16x4'-8 7/8 WDH2O46E(2) WPW5646 Andersen 7 9'-10 13/16x4'-8 7/8 WDH2O46E(2) WPW5646 Andersen 8 F-8 1/2 x 2'- 11 15/16 CN13 Andersen 9 P-8 1/2 x 2'- 11 15/16 CN13 Andersen 10 1'-8 1/2 x 2'- 11 15/16 CN13 Andersen 11 F-8 1/2 x 2'- 11 15/16 CN13 Andersen 12 1'-8 1/2 x 2'- 11 15/16 ICN13 Andersen 13 F-8 1/2 x 2'- 11 15/16 ICN13 Andersen Doors Mark I Unit Dimension Unit Code/Item Size I Remarks D1 5'-11 1/4 x 6-7 1/2 IFWH6068 Andersen D2 T-3 21/32 x T- 11 1/2 FC58FC58SL(2) Therma-Tru // WINDOW SCHEDULE Job Site/Address: R/'dce7-/1i,,, W, W-rord - 33D Pb_ Date: Owner: 511/r,H Application No. Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Modelrrype Stock Openin Opening Glass/Vis Egress/Cie Opening Opening or Instructions Letter on Name Numbe g Height ible Vent ar Width In Height Plan Call Width Light Opening Inches In Inches 1� Size ITNDE �oN DBL,NU Nf 20210 2GyK -3(0�g "` ,� 2"!b' - , + 6 2r %r r;y aLe�SRF, AWMXAfjJ- jyr 2970" 2-t r f /,0 1 ;7 ` 1 woaflw t wp S r( L. HUNG— 34e,4 4ye` 6,37 377/8" lI II ioDsr✓ 9=r1'L 1/'3%8" 4$ 3.68(2) 7 H Ir It v , n i // G^SEMe"r GN 7 8 FIxEo, 13 Zl 3670 rc 4 Example Entry A Andersen Narroline 3062 3' 2 6'5 '/2 15.30 8.36 6.01 34 2415/35" Tempered Double 1/3" 11/16 Glazing Hung I CADocuments and Settings\Sue\Local Settings\'Temp\Window Schedule.dw //�� WINDOW SCHEDULE Job Site/Address: 11#W-sdA1- 33 W4,,,✓FFaeo 27), /, Date: Owner: 4/ad�ay Application No. Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening GlassNis Egress/Cle Opening Opening or Instructions Letter on Name Numbe g Height ible Vent ar Width In Height Plan Call Width Light Opening Inches In Inches Size nn GNS&nnfN7 GN 1\ 112, rlNp¢RSO�/ FIXED � /3 /3 I Example Entry A Andersen Narroline 3062 3' 2 6'5 '/: 15.30 8.36 6.01 347-2415135" Tempered Double 1/3" 14 1Glazing Hun CADocuments and Sctdngs\Sue\Local Settings\Temp\Window Schedule.doc Job Site Address: 21V,:�6 -,`ki' , 17 lVrdnl- 33Date: Owner: -sflM F— Application No. File No. Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req. Light Actual Req.Vent _Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet it / G ME WDM pylS �S.'/ R6L� /Z7�L.R �� y�, 6 C/1, Zv. 3 a/dcn S Joo/s l3) C�f}7Jt /dS ,y 3.68 �J, i 2.1d 2,16 BDA,*. 20 S" /6,5� /(,,PY g,Z 2,Yi /.37 �.r } R L:\SueHemingway\Building.PemtiLFORMS\NaLLighL Ventil.Calculation.Sheet.doc 33' 20' 13' T-12• 7.42" 7 " T_12. D2 : z 82" 2-S Kitchen B' Bath 4 532 12'-9q" T 4' Double Deep closet 4' L o 4•-28 —lV�i 30142" F,¢Place 3042" 3 Living room Bedroom 6-38' 16'_8" 8 l0' 12'-787O Co� S� 4 6' D 1 2-s 4'-2" � 5 6_38• 6 "( 10_�7_l 3-- •_g 20' • 13' 33' Smoke Detectors: 1-Bedroom, 1 Living Room Kim&Bruce Hanson Carbon Monoxide Detectors: I-Living room 33 Hanneford rd. NOTICE Queensbury,NY SMOKE DETECTORS ARE REQUIRED IN B t 583-1363 (518)656-3182 fit ADJACENT TO BEDROOMS,AND ON EACH FL 10) 1X Kyle Hanson 8/13/04 INCLUDING CELLAR OR BASEMENT. ALL DETECTORS SHALL BE INTERCONNECTED ON ALL LEVELS. ALL SMOKE DETECTORS MUST BE BATTERY BACKUP. CARBON MONOXIDE DETECTOR REQUIRED OUTSIDE LOWEST SLEEPING LEVEL. Fo-�wt<rms aeek < .n' U a,t !J(F V(Illi4m S 0154 Ho p ILIp r -' _ _- _�y� j�_�nm_ s.15' S.BS•oe•eo^� -� Q �Jd> �!`�l U Z3C 9Z' .� 4' q?qt7--_^ 1 se• vts• «s. itr. . (�L, S•�]el. //,V 7 Irl Pa.PPerr (�/O� V _ I r,-' sui...,`....�_ —__ •/ .. .. .- 6tns,S F+I�NonD " T(6? ^--.__• i _ � _ - _ � .._�_-_ _L/� ., ,( ,��6rVIGC� e•�q'_�' } `K eP.a` O.'t•E A.t i Sp<.<e . 'g h 7r.^•+U /1 .:..?. .a W V• 6T uc• ��� � ' 7a6•l9' W _ 2 00 NY 1 W o / o N�F S1'epherl fit' S0.moil Moist Twist � � ! � 11'' W V NC6 or roof e.a•,Ii.W.11-C '))EEF P-EFF.RFY<:c OA MIj•li'�'Cf.reP, � T Q WcuCA ST4V•41 - � J � t C - l� WAwNw, ,'kN1N44 bl,.Gu E Jam•( 1, w69 15M-66( :O L) 7/?8- NOru O�+N 4n 6Y'. VnN ti Pntov . ,a/9P• Dcca /rv0 VA OfOfCp'[10[I. A>Or1 BY O.Urg L 1 a. t - NAP OF A 3,1RVEY NAVE FUR . Bl TO l.*n µc PA2T .0 zn[ 1<r rwt Sr<K mlam,wr MVH PF' 00 CEN56uf-'1' WAR2EN. CDUNTY, N.Y. q� u1ti,y.. A. LA't'a10., armetcu Ma.wxvnn fR•[T w"'®.1x.A Ori,/L V x two nlnllgtf SCALE, I•'. 3 e" DATE. ,O e C. 4, 159 C '�..,•�S�soa+•s.w -F t9 ZI cr,wu.a muoD�m x c rxn les tn.¢• Steves r Y3 MN.Y Mi tRn.O M w3sOn4 SM M C '� 651,0 fKC K ACYS IOt I.wO iR(lUti wv� tr l<M nYR aAn:Asamxsa a niomar. LAND SVRYLYORY11AEas FN ulm MV.. _ '(B - y wo awrcloi¢ara ox�le�me nw,wa,oar / TOKrua,W[.bxuv.<s.VM�I/O - t.P.F. i4• SPE ivuve r' \ mw nuu la K<N[m..ir,.cww<yc. .KY: STATE LIC.. ND. 35617 LA.f. N wp.,'wo town�rM'a,lsa wms xa -- Les Sc,' — w xmos n x tno.a wFnsro<• W - CVHv .•1, 91 ra_ 1.n•51 - 9(119 E r.. Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: L4 Queensbury Building & Code Enforcement Arrive: am/tart: &14., tam/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 1 7 NAME: hI PERMIT #: `/-fig l LOCATION: �_ J '.tl 1A INSPECT ON: It TYPE OF STRUCTURE: Y N NIA Rough Plumbing / Nail Plates Plumbing Vent 1 Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation / Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct to e COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 FA�d 0-�, Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: l9 3-1y Queensbury Building & Code Enforcement Arrive: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Cans b A PERMIT#: 6-q -& / LOCATION: 3 INSPECT ON: Io--ia -1 TYPE OF STRUCTURE: Y N N/A Plumbing under slab 'EOrnbing /Nail Plates Plumbing Vent/Vents in Place 11/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. for 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I. for for 15 minutes Insulation / Residential Check/Commercial Check Window Sealing Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape Blower Door Test Air Sealing COMMENTS: Rough Plumbing—insulation Inspection-02 0513 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requestr c 'ved: Queensbury Building & Code Enforcement Arrive: am/ epart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: � L PERMIT #: ' 60/ ��O LOCATION: INSPECT ON: ((2 -Q TYPE OF STRUCTURE: Y N/A u h Plumbin / Nail Plates V c�N �— Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction PFessure Test Drain / Air ead 5 P. ft. above highest connection for 15 minutes Press est ater Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation Residential Check / Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Town of Queensbury Fire Marshal C�1(1Ytt� �� — �QbL((ft'aj'✓11A 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Masonry Chimney /Fireplace Inspection Report 1 3 ` Permit#�y i�I t Schedule Inspection 1i 0 pm anytime Rough In Final q_ Name lrtt }IQ.1� AddressGt b�N���1 ��IJJJ Inspector Ji Yes No N/A Comments FOOTING Concrete or solid masonry �,k` I ��� � �xI 41✓� Cj ck Minimum 12"thickness l Extends minimum 6"beyond Up on all sides Below frost line Cleanout opening-noncombustible cover FIREBOX r• I // Wafts must be solid-no hollow masonry allowed �•i /�;/ -�`\r� (it� N C G'CC - 8"minimum thickness-back/side walls Z. ��� l Joints between firebricks-Y;' max `x, 1 Refractorymortar used on firebrick I\ Minimum depth 20" !�� ��� l"l �Vl� �i'��P"C� C�? `{C'�e'�C��y Fresh air intake / I� \'61�Y.' / i4 C-" ✓f' I / Clearances to combustibles: 4"rear,2"sides/front `VtX 1111 LINTEL/THROAT Non-combustible material Minimum 4"bearing length each end Damper installed,minimum 8"above Vp opening SMOKE CHAMBER Walls must be solid—no hollow masonry allowed Minimum wall thickness 6"including liner Firebrick lining laid with refractory mortar CHIMNEY Minimum wall thickness 4"-solid masonry!'\ Must be lined with appropriate liner typex } // Clay flue liner laid with refractory mortar ., I, c)K\ Flue liner smooth surface inside,no mortar Minimum masonry thickness between flues 4" V\, Minimum clearances to combustibles 2"for interior chimneys,1"for exterior Termination height minimum 3 feet above highesfx point of roof where it passes through,2 feet above any combustible construction within 10 feet / / Chimneyca installed ' A� •CII HEARTH/HEARTH EXTENSION Constructed of concrete or masonry Supported by noncombustible material No combustible material on underside (? n O i Minimum thickness 4"-hearth only fit/ Minimum thickness 2"-hearth extension Hearth Extension-16"to the front,8"to sides I NOTE: if F/P opening is greater than 6 sq.ft.,must I P ^ ,JL extend 20"front,12"sides l�'^ 1 6F i te° 'L ' _ MANTEL/TRIM ` No combustibles within 6"of F/P opening Combustibles within 12 inches of F/P opening cannot project more than 1/8"for each inch distance from F/P opening Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: O Queensbury Building & Code Enforcement Arrive: a /Depart: 2' an-/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial 510 NAME: PERMIT#: QO Lnd-� ''II LOCATION: INSPECT ON: O 0 '7:00 fin. TYPE OF STRUCTURE: 1 Framing Y N N/A COMMENTS Jack Studs/Headers ����/��L fi2• Bracing/Bridging Joist hangers U 5 /ev6F Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/: w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Repon.doc January 28,2003