Loading...
SOLAR-00179-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761.8201 — Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000179-2017 Date Issued: Friday, June 16, 2017 This is to certify that work requested to be done as shown by Permit Number SOLAR-000179-2017 has been completed. Tax Map Number: 303.5-1-4 Location: 11 MEADOW13ROOK RD Owner: Joseph Hubert Applicant: Solar City This structure may be occupied as a: Solar Panel System 486.81 s.f. By Order of Town Board TOWN OF QUEENSSBUR�YJ Issuance of this Certificate of Compliance DOES NOT relieve the r I r/ /J property owner of the responsibility for compliance with Site Plan, (GG��++ V Variance,or other issues and conditions as a result of approvals by the Director of Building&Cade Enforcement Planning Board or Zoning Board of Appeals. �- TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000179-2017 Tax Map No: 303.5.1-4 Permission is hereby granted to: Solar City For property located at: 11 MEADOWBROOK RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Joseph Hubert Solar Panel-Residential $10,793.00 Owner Address: l l MEADOWBROOK RD Total Value $10,793.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Solar City PO Box 670 Amsterdam,NY 12010 Plans&Specifications Solar Panel System 486.81 s.f. $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,April 28,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town ofens iday ri 7 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement 0 '-" Office Use Only ACCESSORY STRUCTURE APPLICATION Received OW DATE 4 - 21 - 17 Tax Map ID TAX MAP ID 303.5 - 1 -4 Permit No. 1�- ZONING Permit Fee 1 IS HISTORIC SITE _Yes _No AeCrovalshD� SUBDIVISION NAME Lot# APPLICANT Loreen Harvey OWNER Joseph Hubert ADDRESS P.O. Box 670 ADDRESS 11 Meadowbrook Road Amsterdam, NY 12010 Queensbury, NY 12804 PHONE 518 - 332 - 0671 PHONE 5188123328 CONTRACTOR Solar City COST OF CONSTRUCTION(ESTIMATED): $ 10,793.00 ADDRESS: P.O. Box 670 BUILDING ADDRESS: 11 Meadowbrook Road Amsterdam, NY 12010 Queensbury, NY 12804 PHONE: 518 - 332 - 0671 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE Loreen Harvey PHONE 518-332-0671 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1slfloor sq.ft. 2nd floor sq.ft. Total sq.ft. Height Boathouse with Sundeck Deck Detached Garage(#of cars Dock Pole Barn QUEENSBUR Porch-open B "Porch—3 season, Covered,Enclosed Shed Other Accessory Structure(s) 486.81 sq ft "Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above: Print Name: Loreen Harvey Date: 4 - 21 - 17 Signature: Date: 4 - 21 - 17 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 ABBREVIATI®NS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. TOWN OF QUEENSBURY (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING BUILDING DEPARTMENT EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, Based on our limited examination,compliance FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE with our comments shall not be construed as GALV GALVANIZED HAZARDS PER ART. 690.17. indicating the plans and specifications are in Cq GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE full compliance with the Building Codes of op GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY New York State. ti �- HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. p 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL CD Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER TOWN OF QUEENSBURY � (`� Q � � kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR D kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDING & CM—:'S BP® J T. O 0 in O C. O >' LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). �{ {eWO Y: _ _ _ o APR Li 2017 MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN L y (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY Dace: — 7111 - O N NEUT NEUTRAL UL LISTING. TOWN Ot= SUE-EENSBURY '� .0 N NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE BUILD1r-,IG 9:CODES CU a- OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE �A N " PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING MC 5 O POI POINT OF INTERCONNECTION HARDWARE. M U) PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAIN11GHT PVI COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THEE LICENSE GENERAL NOTES Cut heets Attalch dDIAGRAM 1. ALL WORK SHALL COMPLY WITH THE 2015 IBC/IRC per 2016 NYS UNIFORM CODE. 9,. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH ;.yi'`r'►�� c" THE 2014 NATIONAL ELECTRIC CODE. 3. ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE MODULE GROUNDING METHOD: ZEP SOLAR 4. ALL WORK SHALL COMPLY WITH THE 2015 AHJ: Queensbury Town, Warren County INTERNATIONAL FIRE CODE r REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid (Niagara Mohawk) CONFIDENTIAL- THE INFORMATION HEREIN � NUMBER: J[3-1281764 00 PREMISE OVINER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JOSEPH HUBERT Joseph Hubert RESIDENCE Bertha Paz Mendez ®®,��o���'�I°t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ®'��. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 11 MEADOWBROOK ROAD 8.775 KW PV ARRAY ORGANIZATION, EXCEPTPART TO OTHERS IDE THE RECIPIENTS IIN CONNECTION WITH QUEENSBURY, NY 12804 MODULES: 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (27) SOIarCity Standard #SC325 PAGE NAME: SHEET: REV: DATE Son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NOLAREDGE ERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. # SE760OA-US002SNU2 COVER SHEET11 P V 1 4/20/2017 (888)-SOL-CITY(765-2489)wwW.9oIarclty.com PITCH: 26 ARRAY PITCH:26 MP1 AZIMUTH:85 ARRAY AZIMUTH:85 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 26 ARRAY PITCH:26 MP2 AZIMUTH:265 ARRAY AZIMUTH:265 MATERIAL: Comp Shingle STORY. 2 Stories PITCH: 45 ARRAY PITCH:45 MP3 AZIMUTH:265 ARRAY AZIMUTH:265 MATERIAL: Comp Shingle STORY: 1 Story 3' FSB I �dlt� 12/12 C I I I I 3' FSB LEGEND — — —3' FSB (E) UTILITY METER & WARNING LABEL 3 FSB Front Of House INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS I m © DC DISCONNECT & WARNING LABELS © AC DISCONNECT & WARNING LABELS 0 DC JUNCTION/COMBINER BOX & LABELS I00 001 B + . III TI + A DISTRIBUTION PANEL & LABELS t Ip LC k1/9 LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER I RSD RAPID SHUTDOWN I I T0 STANDOFF LOCATIONS AC I 3' FSB - - - CONDUIT RUN ON EXTERIOR _ I-__J l CONDUIT RUN ON INTERIOR AC GATE/FENCE O Inv LADDER ACCESS POINT O HEAT PRODUCING VENTS ARE RED r, INTERIOR EQUIPMENT IS DASHED L=�J SITE PLAN N Scale: 1/8" = 1' WE 0 1' 8' 16' S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-1281764 00 ®®\ CONTAINED SHALL NOT BE USED FOR THE JOSEPH HUBERT Joseph Hubert RESIDENCE Bertha Paz Mendezty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: `�- NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 11 MEADOWBROOK ROAD 8.775 KW PV ARRAY dvo PART TO OTHERS OUTSIDE THE RECIPIENT'S QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (27) SolarCity Standard #SC325 3055 Clearvew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET- REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARgTY INC. INVERTER. T:(650)63B-1028 F:(650)638-1029 SOLAREDGE # SE7600A—US002SNU2 SITE PLAN PV 2 4/20/2017 (888)—SOL—CITY(765-2489)www.solarcity.com S1 S1 „ 0 7'-7" '-3" (E) LBW —4 �5—7 11—1" (E) Lew SIDE VIEW OF MP1 NTS SIDE VIEW OF MP3 NTS C MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 48" 23" 41" O„ STAGGERED LANDSCAPE 72" 24" 41" 0" STAGGERED PORTRAIT 24" 151, 62" 0" PORTRAIT 48" 21" 62" 0" TOP CHORD 2X4 @ 24"OC ROOF AZI 85 PITCH 26 STORIES: 2 ROOF AZI 265 PITCH 45 ARRAY AZI 85 PITCH 26 RAFTER 2x6 @ 24"OCARRAY AZI 265 PITCH 45 STORIES: 1 BOT CHORD 2X4 @24u OC Comp Shingle C.J. 2X6 @24"OC Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE Pv. X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER S1 ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT HOLE. ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT TO ND ATTACH ZEP FLASHING INSERT (3) (2) MO RAFTER OUNTING BUS NG LOCK L AG SCREW. 0 7'-7" —G'-3" (E) COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING (E) LBW INSERT PORT, WHICH SPREADS NTS (E) ROOF DECKING (2) (3) SEALANT EVENLY OVER THE B SIDE VIEW OF MP2 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP LANDSCAPE 48" 23" 41" 0" STAGGERED (4) OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN WITH BOLT. PORTRAIT 24" 15" 62" 0" START DOFF ARRAY AZI 265 PITCH 26 TOP CHORD 2X4 @ 24 OC ROOF AZI 265 PITCH 26 STORIES: 2 1 BOT CHORD 2X4 @24" OC Comp Shingle Scale: 1 1/2 = 1 X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PREMISE OWNER: DESCRIPTION: DESGN: CONFIDENTIAL— THE INFORMATION HEREIN Joe NDMBER: JB-1281764 00 JOSEPH HUBERT Joseph Hubert RESIDENCE CONTAINED SHALL NOT BE USED FOR THE Bertha Paz Mendez ' 5(darGfty.BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 11 MEADOWBROOK ROAD 8.775 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES THE SALE AND USE OF THE RESPECTIVE (27) SolarCity Standard #SC325 3055 gearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME M REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 SOLAREDGE SE7600A—US002SNU2 STRUCTURAL VIEWS V 3 4/20/2017 (888)—SOL—CITY(765-2489)www.solarcity.com UPLIFT CALCULATIONS Design Software Mounting Plane Information Roofing Material Comp Roof Roof Slope 450 Rafter Spacing 24"O.C. Framing Type/Direction Y-Y Rafters PV System Type SolarOty SleekMount'" Zep System Type ZS Comp Standoff Attachment Hardware Comp Mount SRV Spanning Vents No Wind and Snow Desi n Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Ultimate Wind Speed V-Ult 115 mph Fig.1609A Exposure Category C Section 26.7 Ground Snow Load pg 50.0 psf ASCE Table 7-1 Surrounding Roof Snow 26.9 psf ASCE Eq:7.4-1 Roof Snow Over PV Modules 14.6 psf ASCE Eq:7.4-1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2) Equation 30.3-1 24.4 psf Wind Pressure Ext.Pressure Coefficient U GC U -0.95 Fig.30.4-2AI8/C-5A/B Ext.Pressure Coefficient Down GC Dorm 0.88 Fig.30.4-2A/B/C-5A/B Design Wind Pressure p p=gh(GCp) Equation 30.4-1 Wind Pressure Up POP) -23.2 psf Wind Pressure Down down 21.4 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 41" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -260 lbs Uplift Capacity of Standoff T-allow 548 lbs Standoff Demand Ca ad DCR 47.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 62" Max Allowable Cantilever Portrait 21" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 21 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -262 lbs Uplift Capacity of Standoff T-allow 548 lbs Standoff Demand/Capacity DCR 47.7% CONJB-1 281764 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE JOSEPH HUBERT Joseph Hubert RESIDENCE Bertha Paz Mendez asDao�oO�� � BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 11 MEADOWBROOK ROAD 8.775 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (27) SolarCity Standard #SC325 PAGE NAME SHEET: REV. DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE7600A—US002SNU2 UPLIFT CALCULATIONS PV 4 4/20/2017 (888)—SOL—CITY(765-2489)wrm.soloroity.aom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:LC404OB1200CU Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ## SE760OA-US002SNU LABEL: A -(27)SolarCity Standard #SC325 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:31810819 Tie-In: Supply Side Connection Inverter; 76'OOW, 240V, 97.57.; w/Unifed Disco and ZB, AFCI PV Module; 325W, 306.5 PTC, 40MM, Blk Frm, MC4, 600v, ZEP, 96-C Underground Service Entrance INV 2 Voc: 69,6 Vpmax: 57.6 INV 3 Ise AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER Disconnect CUTLER-HAMMER I 4 Disconnect 3 SOLAREDGaSNU2 Dc+ A 40A SE760OA-US00DC- MP 2,MP 3: 1x15 AB Lt z�av ---------------------- EGC------------------J 20OA/2Pe N 2(E) LOADS GND GND _-___________-________--- EGCI i + GEC N DC. c MP 1: 1x12 ® GD p ----------- ------------ ----- I (1)Conduit Kit; 3/4"EMT N I I I p I z z I c� I TO 120/240V SINGLE PHASE UTILITY SERVICE I I I EGC ON ROOF TO BE ROUTED WHERE NOT SUBJECT TO PHYSICAL DAMAGE. WHEN ROUTED SUBJECT TO PHYSICAL DAMAGE THE SIZE MUST BE INCREASED TO #6 SOLID BARE COPPER. Voc* = MAX VOC AT MIN TEMP POI (2)ILSCO pIPC 4/0-#6 A (1)CUTLER-HAMMER #DG222NRB P V (27)SOLAREDGE y P40D-5NM4MZM Insulation Piercing Connector, Main 4/0-4, Tap 6-14 Disconnect; 60A, 240Vac, Fusible, NEMA 3R AC PowerBox tl"ptimizer,40OW, ZEP ®C SC SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE -(I)CUTLER-{1AMMER.#OG10ONB Ground/Neutral It; 60-100A, General Duty(DG) AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)CUTLER-HAMMER #DS16FK Class R Fuse Kit -(2)FERRe Z40 A W50V,#TR40RK5 PV BACKFEED OCP B -(1)CUTLER-HAMMER #DG222URB Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R (1)CUTLER-tIAMMER #DG100N8 Ground/Neutral It; 60-100A, General Duty(DG) (1 AWG#6, THWN-2, Black 1 AWG#8, THWN-2, Black (2)AWG#10, PV Wire, 60OV, Black Voc* =500 VDC Isc=15 ADC ® Cn (1)AWG#6, THWN-2, Red O 0)AWG#8, THWN-2, Red O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.75 ADC (1)AWG#fi, 1HWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC (1)AWO#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC (1 Conduit Kit; 3/4" E)AT...,. , 7(1 AWG .. . .... .. .. .. . ... . . .. . .. . . ..... Solid Bare Co er GEC 1 Conduit Kit; 3 4 EMT - 1 AWG .#6.. .. .P.. pp ( ) / . .... . ( ) ,A.TH,WN-2,,Green „ EGC/GEC,-(1)Conduit.Kit;.3/4",EMT,, , , ,, ,, ,. (2 AWG#10, PV Wire, 600V, Black Voc* =500 VDC Isc=15 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=11 ADC (1)Condult Kit; 3/4".EMT ... .. .. .. .... .... .. .. . . . . .. . . .. . . . . . . .. .. PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIALAL- THE INFORMATION HEREIN JOB NUMBER: JB-1 281764 00 p JOSEPH HUBERT Jose h Hubert RESIDENCE Bertha Paz Mendez CONTAINED SHALL NOT BE USED FOR THE t� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ®•.,,c NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing-Insert 11 MEADOWBROOK ROAD 8.775 KW PV ARRAY ►e� PART TO OTHERS OUTSIDE THE RECIPIENT'S QUEENSBURY, NY 12804 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES THE SALE AND USE OF THE RESPECTIVE (27) SolarCity Standard #SC325 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV. DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 SOLAREDGE # SE7600A-US002SNU2 THREE LINE DIAGRAM PV 5 4/20/2017 (888)-SOL-CITY(765-2489)www.solarcity.com Label WARNING:PHOTOVOLTAIC POWER SOURCE Label • ' WARNING -•Location: WARNING Label • • Per Code: Per Code: Per Code: NEC 690.31.G.3 ELECTRIC SHOCK HAZARDNEC ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS '•1 THE DC CONDUCTORS OF THIS 690.35(F) Label • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE • :E USED WHEN LOAD SIDES MAY BE ENERGIZED UNGROUNDED ANDINVERTERIS PHOTOVOLTAIC DC, IN.THE-OPEN POSITION MAY BE ENERGIZED DISCONNECTPer C •'- UNGROUNDED NEC •.1 Label Location: " Location: PHOTOVOLTAIC SYSTEM MAXIMUM POWER- DE-QUIPPED WITH RAPIDPe Code: POINT CURRENT(Imp)_A Per • _ CEC 690.56(C) MAXIMUM POWER- VNEC •91 POINT VOLTAGE(Vmp) �. MAXIMUM SYSTEM VOLTAGE(Voc) SHORT-CIRCUIT Label L• • Per WARNING ..- INVERTER OUTPUT CONNECTION 690.64.13.7 Label • DO NOT RELOCATE WARNINGPer ••- THIS ODEV CERRENT ELECTRIC SHOCK HAZARD 690.5(C) '- IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE , UNGROUNDED AND ENERGIZEDLabel Location: Per ..- PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEDNEC 690.64.13.4 Label • • Per WARNING ..- ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALSNEC 690.17(4) Label • • OAD S DES MAY BE ENERGIZED CAUTION IN THE OPEN POSITION DUAL POWER SOURCEPer Code: DC VOLTAGE IS SECOND SOURCE IS 690.64.B.4 ALWAYS PRESENT WHEN PHOTOVOLTAIC SYSTEM SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • PHOTOVOLTAIC POINT OF -• Label • • INTERCONNECTION Per PHOTOVOLTAIC AC -• WARNING: ELECTRIC SHOCK NEC / 690.54 Disconnect Per •••- HAZARD. DO NOT TOUCH DISCONNECT TERMINALS.TERMINALS ON Conduit NEC 690.14.C.2 BOTH THE LINE AND LOAD SIDE Combiner :.- MAY BE ENERGIZED IN THE OPEN • • POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE (DC): DC Disconnect AND MAIN BREAKER. (IC): Interior Run Conduit °7 Label • - • (INV): Inverter With IntegratedDisconnect MAXIMUM AC ' -• MAXIMUM AC ALoad Center OPERATING CURRENT APer Code: OPERATING CURRENT __ Meter(M): Utility MAXIMUM AC MAXIMUM AC OPERATING VOLTAGE VNEC 690.54 OPERATING VOLTAGE _ V -• Point of • • 1 1 1' / / 1 1 1 1• �11� M3055 Clearview Way :i / / 1 1' 1 • 1 1Q San Mateo,CA•••1 29 1 MWAi • Ill• 1 • LabelSet 1 • 1 1 1 1 1 1 1 7 1 1 •! � I �} •I Solar o o Single Phase Inverters for North America s1® a1 ® SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ O O SE760OA-US/SE10000A-USISE1140OA-US SE3000A-US SE380OA-US SESOOOA-US SE6000A-US SE760OA-US SE1000OA-US I SE1140OA-US OUTPUT t{0 0��7 9980 @ 208V S c 9 a r E d g e ��u 8�0� Phase D m ve ne vs � Nominal AC Power Output 3000 3800 5000 6000 7600..... .10000 @240V• 11400 VA d7 ooU 5400 @ 208V 10800 @ 208V For North America Max AC Power Output 3300 4150 6000 8350 1200D VA ........ ......... Baso @zaaY.. . .............. ..... @zaov. ............ . .. ................ AC Output Voltage Mm.Nom:Max!') 183-208-229 Vac ............. ................ ............................... ................. ........................... SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ .Outp tVolt.eMi................ AC Output Voltage Min:Nom:Max!') SE760OA-US/SE1000OA-US/SE1140OA-US 211-240-264 Vac .1 .1 A. Frequency Min:Nom:Max.)') 59.3-60-60.5 Hz Max:Continuous Output Current..........1?.5.....I.....16......1..21 @ 240V..I......25.......I......32......I...42.@.240V...I......4�.5..........A.... GFDI Threshold A ...................................................................................................1.................................................................... Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT - verta,.'•.:; Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 15350 W •'< ......................................... ............... .............. ................ .............................................•-. ............... ........ 5 .... _. 2 0`= Transformer-less,Ungrounded Yes _ _ �: _d Veats �€ Max:Input Voltage...::............... .................... .... .. ....500........... ........................................ Vdc .. n Nom DC Input Voltage 325 @ 208V/350 @ 240V•. Vdc �aaian _^> Max Input Currentn).................. ......9.5 1.....13...... .355,@•240V.I......18.......I---...23......1..30;5@240V........345 Adc _._._ Max.Input ShortCircuit Current 45 Adc Reverse-Polarity Protection Yes ,.. ......................................... ...................................................•-•--•------............................................................... Ground-Fault Isolation Detection 6001m5ensitivi ---- -- 0k.Sersi...t1:............. ................. . Maximum Inverter Efficien 97.7 98.2 98.3 98.3 98 98 98 % ......... .............. . .............. ................ ................................................ ............. .......... .. CEC Weighted Efficiency 97.5 97 @ 208V 98 97.5 97.5 97 @ 208V 97.5 % ..... .. ....... .......... ............... .............. ..98.�d 240V.. ........ ...................... ..97;5-@ 240V.. ........................... Nighttime Power Consumption <2.5 <4 W i - ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232.Ethernet,ZigBee(optional) - - - -------- � a _Revenue Grade Data,ANSI C12.1 Optional Rapid Shutdown-NEC 2014`690.12 Yes STANDARD COMPLIANCE - Safety - UL1741,UL1741 SA,UL1699B,UL1998,CSA 22.2 1 ....................................... ......................................................................................... ........ - Grid Connection Standards IEEE3547 . ....................................... .............................................................................................................................. --- - Emissions FCC par15 class B INSTALLATION SPECIFICATIONS - - -- AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG Cinp conduit size.....is'tr... ................................................ ....................1-.tr.i....... ` DC input conduit size/N of strings/ 3/4"minimum/1-3 strings/ 3/4 minimum/1-2 strings/16-6 AWG It AWGra-.nge....................... ......... _ .............. ............14-6AWG .. . Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/ 30.5x12.5x7.2/775x315x184 - HxWxD _.....•775•x315x-260.,._,,, rnrn,•, Weight with Safety Switch.............•---•--•-51.2/23.2•••-•-_ 54.7/24.7 ..•.••_..88 4%401 lb/kg• ..I......... ....................................... • Natural convection Cooling Natural Convection and internal Fans(user replaceable) The best choice for SolarEdge enabled systems fan(user ® Specifically designed to work with power optimizers replaceable) Noise <.25 <50 c1BA o Integrated arc fault protection for NEC 2011690.11 compliance in.-Max.Operating Temperature 13 to+14o/-zsto+6o(-aoto+6o versionavailablet°q 'F/'C Rapid shutdown for NEC 2014 690.12 Range.••••............................ Superior efficiency(98%) Protection Rating NEMA 3R r)For other regional settings please contact SolarEdge support. Small,lightweight and easy to install on provided bracket (3tAngnercmrentsourcemaYbeused;meinverterwillimititsinputcurrenttothevaluesstated. Revenue grade inverter PIN:SE-A-US000NNR2(for 7600W inverter.SE7600A-US002NNR2). e Built-In module-level monitoring - - -40 version PIN:SE-A-USOo0NNU4(for 76MW inverter.5E7600A-U5002NNU4). Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 suns=ec No USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge.us QSOLAREDGE.the SolarEdge logo.OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2017.V.01.Subject to change viithout noUce. ' •SOIarQty I ZepSolar Next-Level PV Mounting Technology ^SOlafClty ZepSolar Next-Level PV Mounting Technology ZS Comp Components for composition shingle roofs �- r' Mounting Block Array Skirt Interlock Part No.850-1633 Part No.850-1608 or 500-0113 Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 4z Flashing Insert Grip Ground Zep V2 Part No.850.1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 1 OOMPgT'6 ti� �F Description PV mounting solution for composition shingle roofs ' rFA �� Works with all Zep Compatible Modules °OMPpj� Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Captured Washer Lag End Cap DC Wire Clip (!� LISTED Part No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-002 (L)850-1586 or 850-1460 Listed to UL 1565 850-1631-003 (R)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations • ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Leveling Foot Part No.850-1397 zepsolar.com zepsolaccom Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solaes sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1939-001 Rev D Date last exported:April 29,201611:22 AM Document#800-1839-001 Rev D Date last exported:April 29,201611:22 AM SC325 SolarCity ELECTRICAL AND MECHANICAL CHARACTERISTICS `y ELECTRICAL DATA MECHANICAL DATA Morepower, sne=, steer Max.power(Pmax)CW] 325 I B— , I _n- Max.power voltage(Vmp)[V] 57.6 Weigh t:42.9916s B. Max.power current(Imp)[A] 5.65 Dimensions:62.6"/41.5"/1.57" less panels . Open circuit voltage(Voc)[V] 69.6 Connector:MC4 ;� li _ Short circuit current(Ise)[A] 6.03 Frame Color:Black Max,over current rating[A] 15 F____ Snow load:5400 Pa Power tolerance[%]' +5/-O 1 Wind load:2400 Pa Max.system voltage[V] 600 A A Fire Type:Type 2 Solar Panel efficiency[%] 19.4 Note:Standard Test Conditions:Air mass 1.5:Irradiance=1000W/m2:cell temp.25-C 'Maximum Power t delivery.For limited warranty conditions,Please check our limited warranty document. _E ♦ TEMPERATURE CHARACTERISTICS E— ' Temperature coefficient of max -0.2 ♦ ® �.• Temp.coefficient of Pmax /'C 1 -0.258 Temp.coefficient of Voc[%/°C] -0.235 m •I ® nt Temp.coefficient of Isc[%/°C] 0.055 11 AT NOCT(NORMAL OPERATING CONDITIONS) I Max.power(Pmax)[W] 247.5 ® Max.Power voltage(VmP)CV] 54.2 ! anml Section A-A' Max.power current(Imp)[A] 4.56 a Open circuit voltage(Voc)[V] 66.1 Short circuit current(Isc)[A] 4.87 Q 0 Note:Normal Operating Cell Temp.:Air mass 1.5:Irradiance=800W/m2 ss Air temperature 20oC;wind speed 1 m/s - /e."11 ow„ary° - ml � AT LOW IRRADIANCE (20%) With a sunlight to electricity More power per panel I SectionB-B' Our 325W panel generates 20%more power than a standard Max.power(Pmax)[W] 62.0 conversion efficiency of over 19.4% 270W panel. Max.power voltage(Vmp)[V] 55.7 O Max.power current(imp)[A] 1.11 DEPENDENCE ON IRRADIANCE the panel ranks amongst the More energy every year Open circuit voltage(Voc)[V] 65.1 zoo - — Short circuit current(Isc)[A] 1.21 More yearly energy(kWh)compared to other panels as they perform Il000wrm highest in the industry. That means better In the heat. Note:Low irradiance Air mass l.5;Irradiance=20OW/m2:cell temp.=25'Cvv 600 - scow/m, our panels can harvest more Outstanding durability 500' N energy from the sun, which means With more than 20 additional tests performed beyond what is LIMITED Power output: 10 years(90%of Pmin) a 400 000w/m, currently mandated,these panels far exceed industry standards. 25 years(80%of Pmin) Workmanship: 15 years it takes fewer of our panels to u 300 More layers,more power 400wim= power your home. Plus they Manufactured by Panasonic for SolarCity,the panel uses 2.00 _ MATERIALS Cell material: 5 inch photovoltaic cells Heterojunction cell technology,which adds a layer of thin film silicon zoowim= generate more power output p g y y Glass material: AR coated tempered glass on to of high efficient c rstalline silicon. Frame materials: Black anodized aluminium too MC4 during the hottest times of the day, Leading warranty Connectors type: a00 Our panels rank among the best in warranty coverage, 0 10 zo 30 40 so so 20 80 even in warmer climates. with workmanship that extends to 15 years. CAUTION! Please read the installation manual carefully voltage(y) before using the products. RoHS! IECG1216 Panels are manufactured by Panasonic to the specification of SolarCity. Panels are only warranted by Panasonic `, OIL7EC O IEC61»0.1 0 if the panels are included in a PV system sold by SolarCity or Tesla. SolarCity and Tesla make no warranties Oh� I�7 Solarcity.com �o...�..,I IEC617302 r._. \\\\\ solarcity.com related to the panels,which are sold as-is. SolarCi[y will handle any warranty claims on behalf of any purchaser. NEON THE%►o.ST InspectnnsLC NORTHEAST ELECTRICAL INSPECTIONS, LLC 65 Albermarle Road Scotia, NY 12302 PHONE: (518) 852-0826 (518) 866-1663 ELECTRICAL INSPECTION CERTIFICATION This is to certify that the electrical wiring and equipment, which is introduced by the named applicant, is in the accordance with the National Electrical Code and local utility company. It also complies with the application on file at the date listed. Date of Final Inspection: 5/30/17 Job#: 1281764 Applicant: Solar City Amsterdam Address: 11 Meadowbrook Road Queensbury, NY 12804 Owner: Joseph Hubert Permit #: 000179-2017 Equipment Installed: (1) Disconnect (1) 760OW Inverter (27) Modules 325W (1) 40A 2 Pole Breaker APO /f/A00 Dave Near Electrical Inspector Northeast Electrical Inspections, LLC