RC-000296-2016 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000296-2016 Date Issued: Friday, January 27, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000296-2016
has been completed.
Tax Map Number: 252.-1-47
Location: 1875 BAY RD
Owner: Joyce Strauss
Applicant: Joyce Strauss
This structure may be occupied as a:2592 SFD Residential Alt.
$50 Permit Renewal fee pd.5/16/16 By Order of Town Board
TOWN
NOOFQUEJ
ENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the [
property owner of the responsibility for compliance with Site Plan, V
Variance,or other issues and conditions as a result of approvals by the
Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building & Codes (518) 761-8256
BUILDING PERMIT
Permit Number: RC-000296-2016 &P 2OW -`'lbb
Tax Map No: 252.-147
Permission is hereby granted to: Joyce Strauss E V I S E D
For property located at: 1875 BAY RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvoe of Construction
Owner Name: Joyce Strauss Single Family-Alteration $10,000.00
Owner Address: 109 Hollis TER Total Value $10,000.00
Yonkers,NY 10701
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2592 SFD Residential Alt.
$50 Permit Renewal fee pd.5/16/16
1'*'.EINEWED
$ 50.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Monday, June 5, 2017
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o` 7�Lp
hu !< 'ay 2000
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit Application
Town of Queensbury - Dept. tfc,1111111111/V Development, 742 Bqv Road, Queensbury, NY 12804 1761-82561
NOTICE BUILDING & CODE ENFORCEMENT
Requirements prior to issuance _
LApermit must he obtained before of this permit: PERMIT FILE NO.=8 construction. No inspectionsPERMITFEEPAID$made until applicant has received Q ZOlibtg Board ActloltID BUILDING PERMIT. All Arra /Use
ants` epams on this application RECREA77ON FEE PAID$
be completed and the signature 0 Plaming Board Action applicant must appear on the REV/EWED BY. _SPR / Subdivision /Other Bnthling Ingmar
fion form. nba n Recreation Fee Payment _
Applicant: %Jtr<cF � wl`/�/Alar s' Owner: �i9ryHV 1,0q/I CP
Address: 7/ E� L'� �r/ �p / 00,
g'Y
Address: 'D r�iOX LAk6 9-,d 9—c
Phone # ( +T/Sl ) >9z- - 7gy5 I'honc # ( )
--- --- ----- ----- -------
Property Location:
Tax Map Number
Subdivision Name:
Section Block 1 nt
NATURE OF PROPOSED WORK: ESTIMATED MARKET VALUE OF THE
New Building: CONSTRUCTION: $�
residence / commercial
Addition to Building:
residence / commercial OCCUPANCY INFORMATION:
Altera uilding: Primary Building -
residence / commercial _Z single Family Dwell ' g
Resi ercial Two Family Dwellin �/�
no change to exterior size Family Dwellin r#C-z/v .
Office
Other Work (describe below) Mercantile `/UA(
Manufacturing
GROSS AREA OF PROPOSED STRUCTURE: Other
1st Floor. . 12 9� sq. ft. 5-y If ADDITION, what will use�'�~
2nd .F1:oor. . .,R / � sq. ft. SZ of new, addition bel :
Other Flouts. . sq. ft.
(not unfinished cellar or basement) ACCESSORY BUILDINGS:
_ Detached Garage2 car
TOTAL FLOOR AREA: -.?5-9Z- SQ. FT. j, Attached Garage(� 2 car
Private-Storage Building
SIZE OF NEW STRUCTURE: Commercial Storage Building
37- LL// Other FEET X 70 FEET —
Foundation Type: Will any second-hand or ungraded
. Number of Stories : 2 lumber be used? If so, for what?
(habitable space or>/1y)
Height (grade to rXdge) : 27 9 feet TYPE OF HEATING SYSTEM:
Number of fireplacels and/oristove ( circle all which applies)
to be installed:- Electric / Oil / Gas / Wood
Forced Hot Air / Baseboard / Other
Person responsible for. supervision of work as regards to building
codes is : %ucg j4- 411 792 2975-
Name Addresss Phone
Builder:
Plumber:
Mason:
Electrician:
DEC7AM710N.- Please sigh below after you have carefully read the statertlerlt.
To the best of my knowledge the statements contained in this application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done on
the described premises and that all provisions of the Building Codc, the Zoning Ordinance and all
other laws pertaining to the proposed work shall be complied with, whether specified or noted, and
that such work is authorized by the owner. Further, it is understotxl that I/we shall submit prior to a
Certificate of Occupancy''or Certificate of Compliance being issued, an AS BUILT PLOT PLAN by
a licensed survedrawn to scale showing actual location of project on premises.
Signature: �--
(owner, owner's agent, architect, ontractor)
Application for Permit—Septic Disposal System
Town of Queensbtoy 742 Bay Road Queensbury, NJ' 12804 (518) 761-8256
1. OWNER INFORMATION:
...._.........................................................................................................
8 S �}
_Location of installation: yr Office Use
File Permit No.
Tax Map No. 2 3 / / / 3 �/
Owner's Name:
Fee Paid
......... ........................_._.......................................................................................
Address: AV/ oJDK/Bti! RIO
2. INSTALLER'S NAME : PHONE NO.
3. RESIDENCE INFORMATION: (circle year of dwelling, indicate #bedroorn(.$) and multiply# of
bedrooms with applicable gallons per bedroom to equal total daily flow)
Year of House: No. of Bedrooms x Computation = Total Dail
1980 or older Z x 150 gaVbdnn = 300
1980— 1991 x 130 gal/bdrm =
1991 —present x 110 gal/bdrm --
Garbage
Garbage Grinder Installed yes_ / no i,
Spa or Whirlpool Installed yes_ / no L_'
4. PARCEL INFORMATION: (circle applicable information & indicate measurements)
To1299rgphy Soil Nature (3reund Water Bedrock or Impervious Material Domestic Water Supply
Mat sand at what depth at what depth nnuiicipal
Rolling loam Jeer feet we t
Steep slope clay if well; watersupply
slope other from any septic-system
depth: absorption is 13 o fl.
other
Percolation Test: (To be completed by licensed professional engineer or architect)
Rate: mlmrle per inch
5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed
professional engineer or architect (unless installed in a Planning Board approved subdivision). Add 250 gallons to the size
of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub.
Septic Tank: //a gallon (min. size 1,000 gal) g—
Tile Field: each bench fl. Total System Length: / 3 9 fl.
Seepage Pit(s): number of _ size of each: __fl. by fl.
Size of Stone to be used: 11 / depth or thickness
Bed System Size: x
Alternative System: length and/or size
6. HOLDING TANK SYSTEM: (if required)
Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons
Note: Alarm System and associated electrical work must be inspected by a Town approved
electrical inspection agency.
7. SIGNATURE & INFORMATION FOR RESPONSIBLE PERSON(please read)
For your protection, please note that pursuant to Section 136-29 of the Code of the Town
of Queensbury, any permit or approval granted which is based upon or is granted in
reliance upon any material misrepresentation or failure to make a material fact or
circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and agree to abide by these and all
requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
Signature of responsible personate
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: �)4 am/pm Depart: am/pm
Date Inspection request receive Inspectors Initials: r 4o
NAME: 1 &' PERMIT#: DD'
LOCATION: /{c,70 DATE:
TYPE OF STRUCTURE: os
Comments:
Yes I No NIA
4" Building Number Address visible from mad
Chimney Height/W Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 Inches or more
Guard at deck,pordves 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracin /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed!regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety gLazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every Level: _ Every Bedroom: _
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 Inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.R-150 sq.ft.vents
Bathroom Fans if no window
Plumbina fixtures
Foundation insulation to floor/Sticker on Panel
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Fumace shut-off within 30 feet or within One of site
Oil Furnace shutoff at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shutoff boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'W Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical•Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receiptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker L S
Site Plan /Variance required � da
Flood Plain Certification if required
Okay to issue C I C or C 10 Temporary Permanent I
L:16uilding&Codes FornsXBuilding&Codes\Inspection FormsWesldential Final Inspection Form_revised_100405.doc; Revised
January 7,2008;Revised 626/08;Revised 12/22/10, Revised 04!13/11
Residential Final Inspection
Office No. (518) 761-8256 Date Inspect on request received:
Queensbury Building& Code Enforcement Arrive: /vam/ m Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: 0 V66PERMIT#: ov
LOCATION: Q DATE:
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof
Roof Complete
Guard 30 in.or more a;stairs,decks,patios
Guard at stairwell at 34 in.or more
Guard at deck orches 36 in.or more
Exterior Finish Complete L r�
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 in.with 10 ft. Vol
Handrail Termination at Newell Post or Wall
8 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler 1 ,{{��
Relief Valves installed ��J%t �� Ure/eF U`/, .9^
Interior privacy/trim/doors/main entrance 36 in. /
Bathroom/Kitchen watertight t4cv
Safety glazing
Window in stairwells safety glazing
Interior Smoke Detectors: /
r
Every level: / Every Bedroom: J // �Mo�e /
Outside every bedroom area: �j7 a!< 111
Inter Connected: / Batter backu : (""� /� / �' J 1J (i✓��ic/R
Bathroom Fans, if no window 1 1e Ttir nt t F
Carbon Monoxide detector 7r�Q�t nein
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
%hour fire door/door closer
Garage fireproofing (' e r./
Duct work Sealed properly �n,/c�� <x, G^ aJP�
Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq.ft.vents
Building No./Address visible from road
Final Electrical // AWS �mh2rJ
Site Plan /Variance required
Final Survey Plot Plan ��� h
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required q n s+st S a ✓ Tin< a ec//ic</
Okay to issue C/C Cert. Of Compliance)
oka to issue Temporary C/O Cert. Of Occupancy)
ka to issue Permanent C/O(Cert. Of Occupancy)
L:\SueHen ingw y\Building.Codes.Inspectim.FORMS\Res.Final Insp.fmm 2.doc edited January 2S,2003
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: ?(6 L) am/p% Depart: am/pm
Date Inspection request received: Inspector's Initials:
NAME: ��(� qK PI" maL,_ PERMIT*
1���
LOCATION: h. DATE:
TYPE OF STRUCTURE: S -1 ora i r,n
Comments:
4" BuildingYes No N/A Number Address visible from road
Chimney Height/'B"VentUrect Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 Inches above grade 9� //'�
Guard at stairwell at 34 Inches or more / ar 14- ,, � /J✓
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Well
Interior/Extedor Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant C & k
Grade awayfrom foundation 6 inches with 10 feet d� /iJve e w
6 inch clearance to sill plate
Gas Valve shutoff exposed/regulator 18 inches above grade LL (•� ���
Interior privacy/Vim/doors/main entrance 36 Inches
Bathroom/Kitchen watertight / //
Safe glazing/Window in stairwells as lazin /i h� S� Ce./�sc iAJ/xc�1„
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: _ Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 Inches x 30 inches(height)In accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.1-1160 sq.ft.vents
Bathroom Fans if no window rim !r ^° 4-
Plumbing fractures L/
Foundation insulation to floor/Sticker on Panel /�e�✓� ` ��e
Duct work sealed properly/Blower Door Test Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency kegs below grade // k
Gas Furnace shutoff within 30 feet or within line of site rM, ijaJ ehopire0
Oil Furnace shutoff at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shutoff boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical;Energy Saving Light Bulbs 500/a
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification if required
Okay to issue C/C or C 10 Temporary ermanen
L:1Buiiding&Codes FormslBuilding&Codesllnspection Fonns\Resldential Final Inspection Form_revisec_100405.doc; Revised
January 7,2008;Revised 626/08;Revised 12/22/10, Revised 04/13/11
Queensbury Building & Code Enforcement - Residential Final Inspection 1— /
Office No. (518)761-8256 Arrive: am/pm Depart: �am/pm
Date Inspection request received: Inspector's Initials:
NAME: i k� b PERMIT#: 2,O�'UV 6
LOCATION: �� 7, 15 y porno f1 DATE:
TYPE OF STRUCTURE:
Comments:
Yes I No NIA
4" Building Number Address visible from road
Chimney Height/'B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbi Vent through roof minimum 18 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 Inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shutoff e /regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom: _
Outside every bedroom area:Inter Connected: Battery backup:
Attic access 30 inches x 22 Inches x 30 Inches ht in accessible area J
CraW Spaces 18 inch x 24 inch access 1 sq.ft:150 sq.ft.vents
Bathroom Fans if no window
Plumbing fixtures cl 2� (e2-7-4
Foundation insulation to floor/Sticker on Panel (A.^ 53
Duct work sealed property/Blower Door Test Certification
Floor truss,draft stopping finished basement 1 000 sq.ft.
Emergency ress below grade
Gas Furnace shutoff within 30 feet or within line of site C�,� La 3 I I Z
Oil Furnace shutoff at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shutoff boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/'G sum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Gas Logs in Sealed or Glass Enclosure
Final Electrical• Energy Saving Light Bulbs 50%
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required I Z7
Flood Plain Certification if required
Okay to issue C I C or C 10 Temporary/Permanent
LABuilding&Codes FornslBuilding&Codesllnspecfion Fomhs\Residermal Final Inspection Form_revised_l00405.doc; Revised
January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection requ rece' t, .��� zo
Queensbury Building&Code Enforcement Arrive: e c :_k 6=- , "
742 Bay Road,Queensbury,NY 12804 Inspector's Initis
NAME: A A M PERMIT#: Z UQ)
LOCATION: INSPECT ON: '-[IL[.I(1 _
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3, R-4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper,CPVC,Pex One &Two Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
-L:\SueHemingw y\Building.Codes.Inspection.FORMSUtough Plumbing Insulation Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No.(518)761-8256 Date Inspection requ eive i
Queensbury Building&Code Enforcement Arrive: a pm D a i a�
742 Bay Road, Queensbury,NY 12804 Inspector's Ini
NAME: ASS � T#:
LOCATION: —"�� R D An INSPECT ON:
TYPE OF STRUCTURE:
Y N :N/A COMMENTS
Framing
Jack Studs!Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in. �T
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 w 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft, or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
L:\.SueHemingway\Building.Codes.Inspection.FORMS\Fmming Firestopping Inspection Report.doc January 28,2003
Je�Rough Plumbing / Insulation Inspection Re rt
Office No. (518) 761-8256 Date Inspection request .ved: hc Q r!
Queensbury Building& Code Enforcement Arrive: pm De pm
742 Bay Road, Queensbury,NY 12804 Inspector's Init.,Is:
NAME: V PERMIT #: � ��
LOCATION: INSPECT ON: 3
TYPE OF STRUCTURE:
r
Y N N/A
PVC: R-1, R-2,R-3, R4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 '/2 inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Coo er, CPVC, Pex One and Two-Famil
sulatio esidential Check/ Commercial Check
Proper Vent, Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
��c.�-\Eci1�- ti 1 =vim iA M ��+J M o rJ➢�`� �
L:\SueHemingway\Building.Codes.Inspectlon.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Framing /Firestopping Inspection Report
Office No.(518) 761-8256 Date Inspection r uesYwceived:
Queensbury Building&Code Enforcement Arrive: �: a m Depart: r a m
742 Bay Road,Queensbury,NY 12804 Inspector's Ini
lfw9
NAME: q PERMIT
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMMENTS
raming
Jack Studs/Headers
Bracing/Bridging
Joist hangers 'b CAS
Jack Posts/Main Beamsc�
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in, or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft, or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Rough Plumbing/ Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: t-/v am/PP��m�,. Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:/_
NAME: �/ ��i. arlo PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain/Vents
Cast Iron,Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates4�f��; r• '�
Head or Air Supply Test iia F��•� �_° �`�
Drain and Vents �1iJ o}�
5 PSI or 10 ft. above highest ,��e ( A ,L
Connection for 15 minutes
Water Supply Piping
Copper Commercial _ ��r+�/���
Copper,CPVC,Pex One&Two Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent rl�`
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
CONMISTS:
LdSueHeming"y\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
_ i A Framing /Firestopping Inspection Reo�t
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: - y, am/pm Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector s Initials:
NAME: PERMIT#: 6
LOCATION: INSPECT ON: C�
TYPE OF STRUCTURE:
Y N N/A COMMENTS
arcing
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf grade
L:\SueRemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
` Framing /Firestopping Inspection Report q ` /0
Office No.(518)761-8256 Date Inspection req s rec e .
Queensbury Building&Code Enforcement Arrive: a p
742 Bay Road,Queensbury,NY 12804 Inspector's Initi
NAME: PERMIT —� U
LOCATION: o INSPECT ON: 0 Q 3
TYPE OF STRUCTURE:
Y N .arcing N/A COMMENTS
Jack Studs/Headers I \O
Bracing/Bridging `VF�F —�� F
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %x w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft, floor trusses
Anchor Bolts 6 ft, or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2,3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
1 20 in. (W)
5.7 sf above/below grade
Il 5.0 sf grade
L:\SueHemingway\Building.Codn.Inspmtion.FORMS\Fmming Firestopping Inspection Repott.doc January 28,2003
,1
1
............
� Q2,
Ce �