RC-000235-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000235-2017 Date Issued: Tuesday,November 28, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000235-2017
has been completed.
Tax Map Number: 296.14-2-21
Location: 36 DEVIN CT
Owner: CERRONE BUILDERS,INC.
Applicant: CERRONE BUILDERS,INC.
This structure may be occupied as a: Single Family Dwelling w/gas FP 1712
s.f By Order of Town Board
Garage 440 s.f. TOWN OF QUEENSBURY
Village at Sweet Road,Lot 21
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000235-2017
Tax Map No: 296.14-2.21
Permission is hereby granted to: CERRONE BUILDERS,INC.
For property located at: 36 DEV IN CT
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: CERRONE BUILDERS,INC. Single Family-New $340,000.00
Owner Address: 1589 State Route 9 Total Value $340,000.00
Fort Edward,NY 12828
Contractor or Builders Name/Address Electrical Inspection Agency
CERRONE BUILDERS,INC.
1589 State Route 9
Fort Edward,NY 12828
Plans&Specifications
Single Family Dwelling w/gas FP 1712 s.f.
Gamge 440 s.f.
Village at Sweet Road,Lot 21
$1,308.40 PERMIT FEE PAID-TIES PERMIT EXPIRES: Wednesday,May 30,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Qy� pry; 4Enocetment
,2017
SIGNED BY: C for the Town of Queensbury.
Director of Building&Co
Office Use Only
Permit#: �C— 27 S 'ZU i7
PRINCIPLE ST >:am p Fee:$ SO
APP `' Q
Tor.•n ar ueensbury
742 Bay Road,Queensbury,NY 12804 ee:$ SV • 6Q
P:518-761-8256 www.aueensbury.net f4Y ) 2317 i e#:J 71.0'7
Project Location: , F OUEENSB
URY
G& CODES
Tax Map ID#: 1i�lP Subdivision Name:
'TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units: single family,duplexes/two-family,
multiple family, apartments, condominiums,townhouses, and/or manufactured & modular homes, but not mobile
homes. This Is In addition to the permit feels).
CONTACT INFORMATION:
• Applicant'
Name(s): aO - N/A I lletv G
Mailing Address C/S/Z• 4aii�cP( AlY /&WL/
Cell Phone: ( v ) -�Ynl- LM�(Z/ Land Line:
Email:
Primary Owner(s): /fes
Name(s): C
Mailing Address, C/S/Z:
Cell Phone:�_) /^ Land Line:
Email:
• Contractor(s):
Business Name:
Contact Name(s)' /r, P
Mailing Address, C/S/Z:
Cell Phone: �_) Land Line:
Email:
• Architects E ineer s :
Business Name: IC✓lf�
Contact Name(s):
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
Contact Person for Building&Code Compliance:
Cell Phone: ( S�/� ) %�/- h��/ Land Line: 1_)
Email:
Town of Queensbury Building&Code Enforcement Principle structure Application Revised February 2017
PROJECT INFORMATION:
TYPE: Commercial Residential
WORK CLASS:
Single-Family —Two-Family _Multi-Family(#of )
Townhouse Business Office _Retail —Hotel/Motel
_IndustriaiNVarehouse _Garage(#ofcars _i _Other(describe )
STRUCTURE SQUARE FOOTAGE: GARAGE SQ1U/A`RE FOOTAGE:
SST floor: L 1ST floor:
2nd floor: 2nd floor:
3rd floor: Total square feet: `� U
4d'floor:
Total square feet: X 7LZ—
ADDITIONAL PROJECT INFORMATION: /
1. Estimated Cost of Construction: $ �S�OI GI,, f
2. Proposed use of the building: J l)tl 6P nll/� /liJr [i
3. If Commercial or Industrial, indicate the name of the business:
4. Source of Heat(circle one): Gas Oil Propane Solar Other:
(Fireplaces need a separate Fuel Burning Appliances&Chimney Application, one per appliance)
5. Are there any structures not shown on the plot plan? YES NO Explain:
6. Are there any easements on the property? YESNO
7. SITE INFORMATION: �) z t
a. What is the dimensions or acreage a parcel? I�y ��1tL
b. Is this a corner lot? YES NO
c. Will the grade be changed as a resu of the construction? YES
d. What is the water source? PUBLIC PRIVATE WELL
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? Z5&e1_
Town of Q4aensbu.y Baking&Cole En£orS ent Principle SfUCIu,e APPLotion Revised FeMjary?Q
DECLARATION:
I. I acknowledge that no construction shall commence prior to issuance of a valid building permit and
work will be completed within a 12 month period.
2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME:
SIGNATURE: DATE: /D /
Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017
FUEL BURNING APPLIANCE & Office Use Only
CHIMNEY APPLICATION Permit#:
Permit Fee:$
'town of(Zuccns6un•
742 Bay Road, Queensbury, NY 12804 Invoice:#:
P:518-761-8256 www.ciueensbury.net
Project Location: i/iLl L!'. 14 Zil Tax Map ID#:
Room of Install: 1 / Planned Install Date: 29lu 2017
**ONE APPLICATION PER APPLIANCE**
CONTACT INFORMATION:
• Applicant:
Name(s):
Mailing Address, C S/Z: V tYl
Cell Phone: Land Line: � )
Email:
• Primary Owner(s),
Name(s):
Mailing Address,C/S/Z:
Cell Phone:_( ) Land Line: _( )
Email:
Installer/Builder:
Business Name: i eLL
Contact Name(s): AIZA
Mailing Address, C/S/Z: e-
C
Cell Phone:_( ) Land Line: _( )
Email:
Contact Person for Building & Code Compliance:
Cell Phone: _( ) Land Line: _( )
Email:
Fuel Burning Appliance&Chimney Application Revised March 2017
FUEL BURNING APPLIANCE INFORMATION:
TYPE OF DEVICE:
Stove _Fireplace Insert _Fireplace
Fuel Fired Equipment(Garage Only, 18" clearance per IMC 304.3)
_Fireplace,factory built** q
**Manufacturer's name: 11�n[ C' Model #:
SOURCE OF HEAT:
Wood Coal _Pellet /Gas
CHIMNEY INFORMATION:
Masonry:
block brick stone
_Flue:
tie _steel _size, in inches
_Material*:
_double-wall _triple-wall insulated
(*Manufacturer's name: /Pf�iL Model#: A
ADDITIONAL INFORMATION:
1. Two inspections are required. A rough-in inspection,prior to installation and a final inspection,after
installation.
2. Manufacturer's installation manual must be available at the time of inspection.
3. Masonry fireplaces &chimneys require plans to be submitted.
4. Twenty-four(24) hour notification is required for inspections.
Declaration:Construction/installation must conform to NYS Fire Prevention&Building Code and/or manufacturer
requirements. The applicant or owner agrees to comply with all applicable laws,ordinances,regulations and all
conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the
required inspections.
I have read and agree to the above:
PRINT NAME:
SIGNATURE: DATE:
Fuel Burning Appliance&Chimney Application Revised March 2017
-------- - - 296.14-2-21 RC-000235-2017
D E C LE 0 W E Cerrone Buiiders, Inc.
36 Devin Ct., VIg. @ Sweet Rd. Lot 21
NAY 15 2017 1 0 SFD w/FP 1712 s.f. & Garage 440 s.f.
TOWN OF QUEENSBUR
BUILDING & CO ES.`_J — (P
E
S W
Job: 36 bEV iN CRT
Manual S Compliance Report pate: May 03, 2077
Entire House
Project Information
For: CERRONE
36 DEVIN CRI; OUEENSBURY, NY 12804
Cooling Equipment
Design Conditions
Outdoor design DB: 55.0'F Sensible gain: 18440 Btuh Entering coil DB: 75.5°F
Outdoor design WB: 71.0°F Latent gain: 4336 Btuh Entering coil WB: 63.1°F
Indoor design DB: 75.0°F Total gain: 22775 Btuh
Indoor RH: 50% Estimated airflow: 1100 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split AC
Manufacturer: York Model: TCHD36S41S3+FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1
Actual airflow: 1100 cfm
Sensible capacity: 0 Btuh 0% of load
Latent capacity: 0 Btuh 0% of load
Total capacity: 0 Btuh 0% of load SHR: 0%
Heating Equipment
Design Conditions
Outdoor design DB: -4.0°F Heat loss: 73314 Btuh Entering coil DB: 64.2°F
!ndoor design DB: 68.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Gas furnace
Manufacturer: York Model: TM9X080B12MP11
Actual airflow: 1100 cfm
Output capacity: 76000 Btuh 104% of load Temp. rise: 50 OF
296.14-2-21 RC-000235-2017
Cerrone Builders, Inc.
36 Devin Ct., Vlg. @ Sweet Rd. Lot 21
Meets are all requirements ofACCA Manual S. SFD w/FP 1712 s.f. & Garage 440 s.f.
2017-May-05 13:18:01
.+- + wrightsoft° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1
ACCN ...ott.langewonhy\Documents\York\36 DEVIN CRT.rup Cale=MJB Front Door faces: N
Residential • Examiner - • Form
RPERi
ACCAe • System D' • • . • Equipment, 16 Mar 08
AkCodS"@camsdareia
QUEENSBURYNY
Header Information
Contractor: REQUIRED ATTACHMENTS ATTACHED
Manual J1 Form(and supporting worksheets): Yes ❑ No ❑
Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes ❑ No ❑
OEM performance data(heating,cooling,blower): Yes ❑ No ❑
Building plan#: Manual D Friction Rate Worksheet: Yes ❑ No ❑
Duct distribution sketch: Yes ❑ No ❑
Home address(Street or Lot#,Block,Subdivision): 36 DEVIN CRT, Entire House
HVAC l CALCULATON .0
Desian Conditions Building Construction Information
Winter Design Conditions Building
Outdoor temperature: -4 -F Orientation: Front Door faces North
Indoor temperature: 68 °F North,Fast,West,South,Northeast,Northwest,Southeast,Southwest
Total heat loss: 73314 Btuh Number of bedrooms: 0
Conditioned Floor area: 5212 ft'
Summer Design Conditions Number of occupants: 0
Outdoor temperature: 85 °F
Indoor temperature: 75 °F Windows Roor
Grains difference: 28 gr/Ib�0% RH Eave overhang depth: 0 ft
Sensible heat gain: 20488 Btuh Internal shade: none '�
Latent heat eln; Blinds,drapes,em. save
9 4817 Btuh OepN Window
Total heat gain: 25306 Btuh Number of skylights: 0
EOUIPMENT SELECTION •
Heating Equipment Data Cooling Equipment Data Blower Data
E(pipment type: Gas furnace EViBment type: SplitAC Heating cfm: 1100
.ace,Heatpump,Boller,etc. Ir ondnloner,Heat pump,etc. Cooling cfm: 1100
Model: York Model: York Static pressure: 0 in H2O
TM9X080B12MP71 TCHD36S41S3 Fan's rated externa l static pressure for
Heatingoutput capaci design almow
HaetumpsPeepe nyatwinteraesign o6 d00 o Beat arts Total cooling capacity: 0 Btuh
Sensible cooling capacity: 0 Stuh
Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh
' • C • •ESIGNJJIRC M1601
Design airflow: 1100 cfm Longest supply duct: 0 ft Duct Materials Used
Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct:
Total device pressure losses: 0 In H2O Total effective length(TEL): 0 ft
Available static pressure(ASP): 0 in H2O Fdctionrtelfrate:Rate=ASP+(TELA t0E)(� in/100ft Branch duct: Sheet metal
Fon
I declare the load
calcuiation equipment,eqUipment selection and duct design • • • • on the building
plan listed • -. I understand the claims made on be subject to review
Contractor's printed name:
Contractor's signature: Date:
Reserved for County,Town Municipality
'Homequalifies for MJ1AE Form based on Abridged Edition Checklist
wrighti!il Right-SufteQD Universal 2017 17.0,16 RSU25116
Pro ect Summa Job: 36DEVINCRY
Date: May 03, 2117
Endre House By:
Proiect Information
For: CERRONE
36 DEVIN CRT, QUEENSBURY, NY 12804
Notes:
Desicin Information
Weather: Glens Falls AP, NY, US
Winter Design Conditions Summer Design Conditions
Outside db -4 OF Outside db 85 OF
Inside db 68 OF Inside db 75 OF
Design TD 72 OF Design TO 10 °F
Daily range M
Relative humidity 50 %
Moisture difference 28 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 66628 Btuh Structure 17206 Btuh
Ducts 6686 Btuh Ducts 1234 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 73314 Btuh Use manufacturer's data n
Rate/swing multiplier 0.90
Infiltration Equipment sensible load 16596 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 2176 Btuh
Ducts 2160 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft' 5212 5212 Equipment latent load 4336 Btuh
Volume W) 46908 46908
Air changes/hour 0.31 0.15 Equipment total load 20931 Btuh
Equiv.AVF(cfm) 239 117 Req. total capacity at 0.70 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make York Make York
Trade YORK Trade HORIZONTAL DISCHARGE
Model TM9X080B12MP11 Cond TCHD36S41S3
AHRI ref 2008691 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1
AHRI ref 3743636
Efficiency 95.5AFUE Efficiency 12.0 EER, 14.1 SEER
Heating Input 80000 Btuh Sensible cooling 23100 Btuh
Heating output 76000 Btuh Latent cooling 9900 Btuh
Temperature rise 64 OF Total cooling 33000 Btuh
Actual air flow 1100 cfm Actual air flow 1100 cfm
Air flow factor 0.015 cfm/Btuh Air flow factor 0.060 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-May-05 13:18:01
WrIght5OftRight-Suite®universal 2017 17.0.16 RSU25116 Page 1
...ott.langmorthy\Documenta\York\36 DEVIN CRT.mp Calc=MJe FrontDoor faces: N
AED Assessment Job: 36DEViNCRT
Daie: May 03, 2017
Entire House By:
Project • •
For: CERRONE
36 DEVIN CRT, OUEENSBURY, NY 12804
Design Conditions
Location: Indoor: Heating Cooling
Glens Falls AP, NY, US Indoor temperature(°F) 68 75
Elevation: 335 ft Design TD (°F) 72 10
Latitude: 43°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference (gr/Ib) 48.0 27.6
Dry bulb (°F) -4 85 Infiltration:
Daily range (°F) - 20 ( M )
Wet bulb (°F) - 71
Wind speed (mph) 15.0 7.5
Test for • uate Exposure Diversity
— -
Hourly Glazing Load
3,500
3,000
2,50
m -------------
2,00
0 1,500--
1,000--
500--
01
,501,0005000
8 9 10 11 12 13 14 15 16 17 18 19 20
Haur of Day
/H uRy /Avemp /AFD 6M1
Maximum hourly glazing load exceeds average by 15.0°/x.
House has adequate exposure diversity (AED), based on AED limit of 30°/x.
AED excursion: 0 Btuh
2017-May-05 13:18:01
wrightSOft• Right-suheo Universal 2017 17.0.16 RSU25116 page 1
ACOA ...ott.langeworthy\DocumentsXYork\36 DEVIN CRT.rup cafe=MJ8 Front Door faces: N
Right-M)Worksheet Job: 36 DEViN CRT
Entire Hones bale: May 03,2017
6y:
1 Room name Entlre House Room1
2 Exposed wall 564.0 ft 188.0 ft
3 Room height 9.0 It d 9.0 ft heat/cool
4 Room dmereiars 1.0 x 1810,0 fl
5 Room area 52120 ft' 1810.0 ft'
Ty Construction U-value Or HTM Arm (ft) Load Area (ftp Load
number (BtuWft;' (BtutVft') a perimaa (ft) (Btuh) a perimeter (ft) (Btuh)
Heat Cod Gross N/P/S Halt Cod Gross N/P/S Heat Cod
6 w 12C-0sw 0.091 n 6.55 1.50 1350 1350 8845 2027 450 450 2948 676
12C-Osw 0.091 a 6.55 1.50 1188 1158 7687 1739 396 366 2398 550
1Dc2ov 0.570 a 41.04 58.17 30 0 1231 1745 30 0 1231 1745
w 12C-0sw 0,091 s 6.55 1.50 1350 1350 8845 2027 450 460 2948 676
11 l(J 12C-Osw 0.091 w 6.55 1.50 1188 1173 7685 1761 396 381 2490 572
�G 1Dc2w 0.570 w 41.04 58.17 15 0 616 872 15 0 616 872
C 16B30ad 0.032 - 2.30 1.44 3515 3515 Sege 5062 113 113 260 163
F 19A-lgbscp 0.049 - 276 0.38 1810 1810 5004 695 1810 1810 5004 695
F 19A-19bscp 0.049 - 276 0.38 8 8 22 3 0 0 0 0
6 c)AED excursion 0 0
Envelope loss/gain 47935 15931 17903 5948
12 a) Infiltration 18693 1274 6231 425
b) Room ventilation 0 0 0 0
13 Intemal gains: OocupffiRs @ 230 0 0 0 0
Applimn aslottw 0 0
Subtotal pines 6 to 13) 66628 17205 24134 6373
Less external load 0 0 0 0
Less transfer 0 0 0 0
Rergstdbution 0 0 0 0
14 Subtotal 66628 17206 24134 6373
15 Duct loads 10% 7% 6686 1234 10% 7% 2422 457
Total mom load 73314 18440 26555 6830
Air reguired(chn) 1100 1100 398 407
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.�A -Pk wrlght a'T- 2017-May-05 13:age 1
Right-Sulte4D Universal 2017 17.0.16 RSU25116 Page 1
...att.langewonhy\Dacumems\York\36 DEVIN CRT.mp Calc=MJ8 Front Door faces: N
Right-®Worksheet Job: 36 DEVIN CRT
Entire Horse Data May 03,2017
By:
1 Roorn name Room2 Room3
2 Exposed wall 186.0 It 21.0 ft
3 Room height 9.0 It heWcool 9.0 ft heat/Cod
4 Room dmensions 1.0 x 1701.0 It 11.0 x 10.0 It
5 Room area 1701.0 ft- 110.0 ft2
Ty Construction Uwalue Or HTM Area (ft') Load Area (ft' Load
number (BtWft-F) (Btulvft2) or perimeter (ft) (Btrh) a perimeter (ft) (Stuh)
HeatCod Gross N/P/S Heat Cod Gross N/P/S Heat Cod
6 w 12C-Osw 0.091 n 6.55 1.50 450 450 2948 676 99 99 649 149
: Vtl 12C-05w 0.091 a 6.55 1.50 396 396 2595 595 0 0 0 0
�—C 1D-c2ov 0.570 a 41.04 59.17 0 0 0 0 0 0 0 0
w 12C-0sw 0.091 s 6.55 1.50 450 450 2948 676 0 0 0 0
11 141 12C-osw 0.091 w 6.55 1.50 396 396 2595 595 90 90 590 135
�—C 1Dc2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0
c 16B-30ad 0.032 - 230 1.44 1701 1701 3919 2449 110 110 253 158
F 19A-19bscp 0.049 - 276 0.38 0 0 0 0 0 0 0 0
F 19A-19bscp 0.049 - 276 0.38 4 4 11 2 0 0 0 0
6 c)AED excursion 0 0
Envelope loss/gain 15016 4992 1 1492 442
12 a) Infiltration 6231 425 696 47
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appfances/other 1 0 0
Subtotal(lines 6 to 13) 21247 5416 2188 490
Leas external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 21247 5416 2188 490
15 Dud loads 10% 7% 2132 388 10% 7% 220 35
Trial roan load 23379 5805 2407 525
Air required(den) 351 346 36 31
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
A& -Fk WrlghtSOft' 2017-May-05 13:age
Right-Sutte®UnNersa12017 17.0.16 RSU25116 Page 2
...ctt.lengeworthy\Docanents\VOrk136DEVINCRT.mp Calc=MJ8 Front Doafaces: N
Right-A Worksheet Job: 36DEVIN CRT
Entire House Date: May 03,2017
By:
1 Room name Room4 Rooms
2 Exposed wall 8.0 ft 0 ft
3 Room height 9.0 R heat/cod 9.0 It heaticool
4 Roan dimensions 5.0 x 8.0 it 6.0 x 8.0 It
5 Room area 40.0 112 48.0 fN
Ty Costruction U-value Or HTM Area (112) Load Area (112) Load
amber (BttHft-F) (Btuh/W) or perimeter (ft) (Btuh) a perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod
6 w 1213-Osw 0.091 in 6.55 1.50 0 0 0 0 0 0 0 0
14! 12C-0sw 0.091 a 6.55 1.50 0 0 0 0 0 0 0 0
T—C 1D-c2ov 0.570 a 41.04 58.17 0 0 0 0 0 0 0 0
w 12C-Osw 0.091 s 6.55 1.50 0 0 0 0 0 0 0 0
11 NU 1213-0sw 0.091 w 6.55 1.50 72 72 472 108 0 0 0 0
T—G 1Dc2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0
c 16B-30ad 0.032 - 230 1.44 40 40 02 58 48 48 111 e9
F 19A-191osco 0.049 - 276 0.38 0 0 0 0 0 0 0 0
F 194-19bscp 0.049 - 276 0.38 0 0 0 0 0 0 0 0
61 c)AED excursion 0 0
Envelope lass/gain 564 166 111 69
12 a) Infiltration 255 18 0 0
b) Roan ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(tines 6 to 13) 829 184 111 69
Less external bad 0 0 0 0
Less transfer 0 0 0 0
Redisinbution 0 0 0 0
14 Subtotal 829 184 111 89
15 Duct bads 10% 7%1 83 13 10% 7% 11 5
Total roan load 912 197 122 74
Air required(chn) 1 14 12 2 4
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
J' 1 —righi50f[` 2017-May-0513:18 age 3
Right-SuBeW Universal 2017 17.0.16 RSU25116 Page 3
...ott.langewodhy%Documents\York%36 DEVIN CRT.mp Cale=MJ8 Front Door faces: N
Right-JO Worksheet Job: 36 DEVIN CRT
Entire House Date: May 03,2017
By:
1 Roanname RocmB Room?
2 Exposed wall 24.0 ft 64.0 ft
3 Room height 9.0 ft heaUcod 9.0 ft hwVcool
4 Room dimensions 120 x 12.0 R 1.0 x 823.0 ft
m
5 Rooarea 144.0 ft' 823.0 ft'
Ty Construction U-value Or HTM Area (Ill Load Area (ft) Load
number (BtuNftk'F) (BtdYft.) a perimeter (ft) (Btuh) a perimeter (ft) (Btuh)
Heat Cod Gross NIP/S Heat Cool Gross WP/S Heat Cool
6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 225 225 1474 338
l4! 12C-0sw 0.091 a 6.55 1.W 0 0 0 0 72 72 472 108
t-f 1D-c2ov 0.570 a 41.04 58.17 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 5 6.55 1.50 108 108 708 162 162 162 1061 243
11 W 12C-Osw 0.091 w 6.55 1.50 108 108 708 162 117 117 767 176
�--li 1D-c2ov 0.570 w 41.04 5517 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 230 1.44 144 144 332 207 823 823 1896 1155
F 194-1gWcp 0.049 - 276 0.38 0 0 0 0 0 0 0 0
F 19A-19bscp 0.049 - 276 0.38 0 0 0 0 0 0 0 0
6 c)AED excursion 0 0
Envelope loss/galn 1747 532 5670 2050
12 a) Infiltration 795 54 2121 145
b) Roan ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2542 586 7791 2195
Less external load 0 0 01 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2542 586 7791 2195
15 Duct loads 10% 7% 2% 42 10% 7% 782 157
Total roam load 2798 628 6573 2352
Air required(cfm) 42 37 129 140
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wright salt' 2017-May-05 4
Right-Suke®Unlversal 2017 17.0.16 RSU25116 Page 4
...ott.lang"odhy\Documents\York\36 DEVIN CRTmp Cale=MJII Front Door faces: N
Right-J®Worksheet Jeb: 36 DEVIN CRT
Entire House Data: May 03,2017
By:
1 Room name Roan8 Room9
2 Exposed wall 28.0 ft 25.0 /t
3 Room height 9.0 ft heat/cod 9.0 ft Ireat/000l
4 Room dimensions 1.0 x 200.0 it 10.0 x 18.0 It
5 Room area 200.0 ft2 160.0 ft-
Ty
NTy Constrwtion ll-value Or HTM Area (ft2) Load Area (112) Load
number (BtuNftMF) (Btuh/ft2) a perimeter (ft) (Btuh) a perimeter (ft) (Btuh)
Heat Cod Gross WP/S Heat Cod Gross WP/S Heat Cod
6 W 12G0sw 0.091 n 6.55 1.50 125 126 826 189 0 0 0 0
t12C-Osw 0.091 is 6.55 1.50 126 126 826 189 144 144 943 216
-0 1Dc2ov 0.570 a 41.04 58.17 0 0 0 0 0 0 0 0
W 12C4)sw 0.091 s 6.55 1.50 0 0 0 0 81 81 531 122
11 lR! 12C-Osw 0.091 w 6.65 1.50 0 0 0 0 0 0 0 0
--G 1Dc2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 2.30 1.44 200 200 461 288 160 160 369 230
F 184-19bscp 0.049 - 2.76 0.38 0 0 0 0 0 0 0 0
F 19A-lgbscp 0.049 - 276 0.36 0 0 0 0 0 0 0 0
6 c)AED excasion 0 0
Emelops loss/gain 2112 666 1843 568
12 a) Infiltration 928 63 829 56
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Applianceslaher 1 0 0
Subtotal Qinee 6 to 13) 3040 730 2671 625
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3040 730 2671 625
15 Duct loads 10% 7% 305 52 10% 7% 288 45
Trial room load 1 3345 762 2940 670
Air regdred(cfm) 50 47 44 40
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
A. 2017-May-0513:
wrightft' D Universal 17.0.16 page
5
...ott.langewodhy\DocmentslVoriek36 DEMN CRTnD Calc=MJ8 Front
Door faces: N
Right-J®Worksheet Jab: 36 DPVIN CRT
Entire House Date: May 03,2017
5y:
1 Room name Raxn10
2 Exposed wall 18.0 It
3 Roam height 9.0 It heaUcool
4 Roam dmensions 1.0 x 176.0 it
5 Room arra 176.0 it'
Ty Construction U-value Or HTM Area (flj Load Area LOW
number (BtUVft;°F) (Btt"ft2) a perimeter (ft) (Btuh) or perimeter
Heal Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coil
6 w 12C-osw 0.091 n 6.55 1.50 0 0 0 0
12C-Osw 0.091 a 6.55 1.50 64 54 354 81
t-1' 1Dc2ov 0.570 a 41.04 58.17 0 0 0 0
w 12C-Osw 0.091 5 6.65 1.50 99 99 649 149
11 W�� 12C-Osw 0.091 w 6.65 1.50 9 9 59 14
1Dc2ov 0.570 w 41.04 58.17 0 0 0 0
C 16B3Dad 0.032 - 230 1.44 176 176 406 253
F 19A-19bscp 0.049 - 276 0.38 0 0 0 0
F 194-19bsop 0.049 - 276 0.38 4 4 11 2
61 c)AED excursion 0
Erwelope loss/gain 1478 498
12 a) Infiltration 597 41
b) Roan vehtilation 0 0
13 Irterral gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 2075 539
Less extemal bad 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 2D75 539
15 Duct loads 10% 7% 208 39
Total roan bad 2283 578
Air regtdred(cfm) 34 34
tet. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
01
A& wrfightsoftRight-Suke®Universal 2017 W.D.16 RSU25116 paage• 2017-May-0513: ge
6
...ott.langewodhy\Documents\York136DEVINCRT.mp Calc=MJB Front Doorfaces: N
fZREScheck Software Version 4,6.4
Compliance Certificate
Project Cerrone Builders Inc
Energy Code: 2015 IECC DOr
2
Location: Glens Falls, New York
Construction Type: Single-family I
Project Type: New Construction
Conditioned Floor Area: 1,712 ft2 TOWN OF QUEENS$Urm.Y
Glazing Area 13% BUILDING& CODES A 4,o 07g060
Climate Zone: 6 (7635 HDD) ROFFSStONP�
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
36 Devin Court CERRONE BUILDERS VISION Engineering, LLC
Lot 21 VISION Engineering, LLC
Queensbury, NY 12804 206 Glen St
Ste 56
Glens Falls, NY 12801
Compliance: Passes using UIA trade-off
Compliance: 0.7%Better Than Code Maximum UA: 287 Your UA: 285
The%Better or Worse Than Code Index reflects how close to compliance We house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or U-Factor UA
Ceiling 1: Raised or Energy Truss 1,712 38.0 0.0 0.025 43
Wall 1: Wood Frame, 16"o.c. 1,920 21.0 0.0 0.057 94
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 191 0.290 55
Door 1: Solid 18 0.140 3
Door 2: Solid 27 0.200 5
Door 3: Glass 40 0.290 12
Basement Wall 1:Solid Concrete or Masonry 1,466 0.0 15.0 0.046 66
Wall height:7.8'
Depth below grade:6.8'
Insulation depth: 7.8'
Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5
Window 3:Vinyl/Fiberglass Frame:Double Pane 6 0.400 2
Floor 1:All-Wood Joist/Truss:Over Outside Air 10 30.0 0.0 0.033 0
296.14-2-21 RC-000235-2017
Cerrone Builders, Inc.
36 Devin Ct., Vlg. @ Sweet Rd. Lot 21
SFD w/FP 1712 s.f. & Garage 440 s.f.
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241- DES-CER Page 1 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Compliance Statement: The proposed building design described he i consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed uildi g has been designed to meet the 2015 IECC requirements in
ES ersion 4.6.4 a comply with the mandatory req ' eme s listed in the REScheck Inspection Checklist
110
Name-Title slur Dffte
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241- DES -CER Page 2 of 10
36 Devin Lot 21\1241 RESCHECK.rck
REScheck Software Version 4.6.4
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Re .ID ___
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PRI]' energy code compliance for the ❑Not Observable
V, building envelope.Thermal -
envelope represented on - ❑Not Applicable
construction documents.
103.1. Construction drawings and "❑Complies
103.2, documentation demonstrate []Does Not
403.7 energy code compliance for
[PR3P lighting and mechanical systems. ❑Not Observable
t,. Systems serving multiple ❑Not Applicable j
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is. Heating: Heating: ❑Complies
403:7 sized per ACCA Manual S based Btu/hr_ Btu/hr ❑Does Not
[PR212 ` 'on loads calculated per ACCA Cooling: Cooling: F_-]Not Observable I
b, :Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable j
Additional Comments/Assumptions:
111 High Impact(Tier 1) ka Medium Impact(Tier 2) 13 ILow Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241- DES -CER Page 3 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Section plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Re .ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
(F0411 insulation R-value.Where interior R_ R- ❑Does Not table for values.
$, insulation is used,verification ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wally` ❑Complies
[F0611 :insulation installed per "=,❑Does Not
manufacturer's instructions. 7.❑Not Observable
[]Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies ;See the Envelope Assemblies
[F06]1 insulation depth of burial or []Does Not ;table for values.
distance from top of wall.
[]Not Observable
!❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
jFOlip .to protect exposed exterior -- []Does Not
14, insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 ;Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
. , ❑Not Observable I
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 IMedium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241 - DES-CER Page 4 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Section
# Framing/ Rough-In Inspection Value Value Plans Verified Field Verified Complies? Comments/Assumptions
& Reg.
402.1.1, Door U-factor. U-_ U-_ ❑Complies ;See the Envelope Assemblies
402.3.4 ❑Does Not ;table for values.
[FR1]1 ❑Not Observable
1
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U-_ U-_ ❑Complies See the Envelope Assemblies
402.3.1, average). -❑Does Not table for values.
402.3.3,
402.3.6, :[]Not Observable
402.5 ❑Not Applicable
[FR2]1
0
303.1.3 -U-factors of fenestration products _ ❑Complies
[FR4]1 are determined in accordance ❑Does Not
-with the NFRC test procedure or ❑Not Observable
:taken from the default table
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable
❑Not Applicable j
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting .❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable
or has infiltration rates per NFRC
400 that do not exceed code - ❑Not Applicable
'limits.
402 4 Sf' IC-rated recessed lighting fixtures ❑Complies
[FR16]z `.',sealed at housing/interior finish ❑Does Not
-and labeled to indicate s2.0 cfm ❑Not Observable
leakage at 75 Pa.
❑Not Applicable j
403.2.1 Supply and return ducts in attics ❑Complies
(FR1211 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_ ❑Not Observable
R-6 where< 3 inches.Supply and
return ducts in other portions of ,.F:❑Not Applicable j
the building insulated >= R-6 for
diameter>= 3 inches and R-4 2
'for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as T ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
.�
[-]Not Observable
�rca'42iw:
[]Not Applicable j
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105 QF or chilled fluids ❑Does Not
below 55 QF are insulated to >_R-
V, ;3 ❑Not Observable I
❑Not Applicable
403.4.1 ,Protection of insulation on HVAC .;❑Complies
[FR24]1 'piping. --❑Does Not
bL ❑Not Observable
❑Not Applicable
403.5SM.,Hot water pipes are insulated to R- R-_ ❑Complies
[FR18]2 'aR-3. - ❑Does Not
❑Not Observable
❑Not Applicable
403.6 (Automatic or gravity dampers are .❑Complies
[FR19]2 ;installed on all outdoor air , , ❑Does Not
iintakes and exhausts. ;,� , .-, ❑Nat Observable i
❑Not Applicable I
1 I High Impact(Tier 1', Medium Impact(Tier 2) 3 1 Low Impact(Tier3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241 - DES-CER Page 5 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Additional Comments/Assumptions:
1 High Impact(Tier 1) -:2'..1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241 - DES-CER Page 6 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Section Pians Verified Pield Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.lU
303.1 All installed insulation is labeled ❑Complies
[IN13]' or the installed R-values ❑Does Not
provided. ❑Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies ',See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not (table for values.
[IN111 ! ❑ Steel ❑ Steel
[]Not Observable
0 ❑Not Applicable j
303.2, 'Floor insulation installed per ❑Complies
402.2.7 :manufacturer's instructions and ❑Does Not
[IN211 in substantial contact with the
,#_, underside of the subfloor,or floor ❑Not Observable
framing cavity insulation is in .❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R-_ R-- ❑Complies ;See the Envelope Assemblies
402.2.5, mass wall with at least 1/.of the table for values.
❑ Wood -❑ Wood ❑Does Not
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ;❑Not Observable
[IN311 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN411 manufacturer's instructions. ❑Does Not
❑Nat Observable
❑Not Applicable j
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241- DES -CER Page 7 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID __
402.1.1, '.Ceiling insulation R-value R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not .table for values.
402.2.2, '.. eel F] Steel 402.2.6 St
'. �❑ ;❑Not Observable
[Fill' .❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI211 Blown insulation marked every ❑Not Observable
300 ft'.
❑Not Applicable
Vented attics with air permeable ❑Complies
insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
-'° _. ,❑Not Applicable
402.2.4 ..Attic access hatch and door R-_ R-_ ❑Complies
[FI311 insulation >_R-value of the ❑Does Not
adjacent assembly. :[]Not Observable
j❑Not Applicable j
402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ I❑Complies
[FI17]1 '.ach in Climate Zones 1-2, and j❑Does Not
<=3 ach in Climate Zones 3-8. j❑Not Observable
j❑Not Applicable
403.2.3 :Duct tightness test result of<=4 cm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft' ❑Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa. For rough-in
-:tests,verification may need to j❑Not Applicable
ttoccurduring Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI2711 determine air leakage with ft2 ft2 j❑Does Not
either: Rough-in test:Total
,leakage measured with a ;❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
.w.g.across the system including
:the manufacturer's air handler
enclosure if installed at time of
!test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system j
including the manufacturer's air
handler enclosure.
403.3.2.1 -Air handler leakage designated ❑Complies
[F12411 by manufacturer at<=2%of ❑Does Not
design air flow. ❑Not Observable
❑Not Applicable
4031.1' ' i Programmable thermostats ❑Complies
[fl9]2 ;installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑No[Observable
"i code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 `- ".on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
Circulating service hot water ❑Complies
systems have automatic or ❑Does Not
accessible manual controls. ❑Nat Observable
!❑Not Applicable
----
11 High Impact(Tier 1) _T 2 Medium Impact(Tier 2) 3'-1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241 - DES-CER Page 8 of 10
36 Devin Lot 21\1241 RESCHECK.rck
'.Section Plans Verified Fieid Verified
# Final inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID= �__
403.6.1 All mechanical ventilation system ❑Complies
(F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy ❑Not Observable
and air flow limits. ❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI26]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback ❑Not Observable
control to lower boiler water
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[FI2812 have a circulation pump.The ❑Does Not
system return pipe is a dedicated []Not Observable
return pipe or a cold water supply
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump -
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable ;
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
(F13 0]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated ❑Not Observable I
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F. _
403.5.4 Drain water heat recovery units ❑Complies ;
[FI31]2 tested in accordance with CSA ❑Does Not
855.1.Potable water-side ❑Not Observable
'..pressure loss of drain water heat
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers.Potable water-
side pressure loss of drain water
heat recovery units<2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[FI611 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. ❑Nat Observable
'..Does not apply to low-voltage
lighting. ❑Not Applicable j
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
kil ❑Not Observable
❑Not Applicable j
1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241 - DES -CER Page 9 of 10
36 Devin Lot 21\1241 RESCHECK.rck
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
401.3Compliance certificate posted. ❑Complies
[F1712 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[91813 mechanical and water heating El Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) -3' Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 04/30/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1241 - DES- CER Page 10 of 10
36 Devin Lot 21\1241 RESCHECK.rck
2015 IECC Energy
Efficiency Certificate
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 30.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.29
Door 0.29
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater•
Name: Date:
Comments
insulSaft" 6� k
Filer Slowing Insulation
Certificate of Insulation
R-VALUE BAG REQUIREMENTS MAXIMUM COVERAGE
TO OBTAIN A THERMAL RESISTANCE OF: BAGS PER IONSO.FT. CONTENTS Of BAG SHWO NOT CMR MOTH TM: SNOKO NOT BE LESS THAN: ENOULD NDT BE LE$81'H11N
H Number of Bags sq.ft. in. in.
R-60 31.4 31.9 22.00 22.00
R-49 25.2 39.7 18.50 18.50
R-44 22.4 44.6 16.75 16.75
3$
19.1 52.5 14.50 14.50
R-30 ) 14.9 67.1 11.75 11.75
R-26 12.8 77.9 10.25 10.25
R-22 10.8 92.9 8.75 8.75
R-19 9.3 107.4 7.75 7.75
R-13 6.2 161.7 5.25 5.25
R-11 5.3 190.5 1 4.50 4.50
This is to certify that CertainTeed InsulSafe®SP Fiber Glass Insulation has been installed to the manufacturer's recommendations and will
achieve an R-Value" of using `j 1" bags of insulation to cover bu square feet of area at a minimum installed thickness of L inches.
g
c)
Metddress, < City State Zip
' A\���� �
Sighed{Instaile Date
Wl\ tti s- C
Company State License Number(if required) D
�1 r 5�c _t G �Il 4` C r 1�D'L)5"
City,State,Zip NOV 29 2017
Keep this certificate with your other valuable papers.If you ever sell this property,this certificate should be passed n to the purchaser.
*The higher the R-Valuc,the greater the insulating power.Ask your seller for the fact sheet n R� >} N OF
QUEENS`^13URY
Cc�N1 Vl1r9Uhit.r1, rt,i_�JEE" lf'f�Et??T
SAW-+��rtaineed
CertainTeed Corporation P.O.Box 860 • 780 E.Efwedeeford Road • Valley Forge,PA 19402 • www.certalnteed.comAnsuistion
FB GRAJNYConsulting, LLC
2017 69 Hayden Point Loop
Diamond Point, NY 12824
TOWN OF QUEENSBURY 518 221-3240
COMMUNITY DEVELOPMENT
11/10/2017
Cerrone Construction LLC
51 Oak Valley Way
Queensbury,NY 12804
Inspection Address: 36 Devin Court, Queensbury NY 12804
Report Number: 1101172
Dear Steven:
The Blower Door Test to verify infiltration rate of the subject property was performed on
11/10/2017. This was done to verify mandatory requirements of 2015 IECC Code as
amended by the NYS 2016 Uniform Code Supplement. This report does not imply that
full compliance of above codes has been met. It's verified the infiltration rates only.
GRAJNY Consulting,LLC is pleased to submit the following report.
The following data was provided:
- Square Footage of the house, including conditioned basement=3,424 SF
- Volume of the house,including conditioned basement=29,104 CF
Based on above,the following test data was collected:
- Infiltration Rate,including conditioned basement at 50 Pascal=982 CFM
- ACH50,Actual Changes per Hour at 50 Pascal=982X60/29,104=2.0<3
The Instruments used for test were provided by the Energy Conservatory Digital Gauge
DG-3 rated accuracy=+/- 1%, calibrated minimum once per year.
Thank you for selecting our company. We appreciate the opportunity to be of service.
Please call this office if there are any questions.
Sincerely,
s4A orf
Stan Grajny, PE
HERS Energy Rater 5609922
NYS PE 065406-1