RC-000255-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development- Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000255-2017 Date Issued: Friday, June 8, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000255-2017
has been completed.
Tax Map Number: 239.18-1-4
Location: 559 LOCKHART MOUNTAIN RD
Owner: Todd Young
Applicant: Patrick Burke
This structure may be occupied as a: Residential Interior Alterations
Living Room and Kitchen 560 sq. ft. By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
�- Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000255-2017
Tax Map No: 239.18-1-4
Permission is hereby granted to: Patrick Burke Construction
For property located at: 559 LOCKHART MOUNTAIN RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvce of Construction
Owner Name: Todd Young Single Family-Alteration $30,000.00
Owner Address: 17500 Gulf BLVD,207 Total Value $30,000.00
Redington Shores,FL 33708
Contractor or Builder's Name/Address Electrical Inspection Agency
Patrick Burke Construction
936 Bay RD
Queensbury,NY 12804
Plans&Specifications
Residential Interior Alterations
Living Room and Kitchen 560 sq.ft.
$84.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,May 30,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the exp. tionAdateky �
Dated at the Town of ueensb {/ /(ues0,2017
SIGNED BY: (�M�_a"V �(� for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
/��
ADDITION/ALTERATION PERMIT Permit#: �
OG
APPLICATION Permit Fee: $ —
Vo;%n of(Zccnsburn p
742 Bay Road,queensbury,NY 12804 Invoice#: f Y C�-� OL '
P:518-761-8256 w�ww.gueensbury.net
Project Location:rJ{r �7 I (emu=HEART mo(9i
Tax Map ID #: Z7l0�� �`C Subdivision Name:
CONTACT INFORMATION:
• Applicant:
TOWN OF QUEENSBURY
Name(s): WUNITY DEVELOPMENT
Mailing Address, C/S/Z:
Cell Phone: Land Line: �)
Email: MI-I/$ 911641Z C+. -MAIG. CONIC
Primary Owner(s):
Name(s):
Mailing Address, C/S/Z:
Cell Phone: (qZ'1) )2&?9i - 20-74 Land Line:
Email: 'T!:JQV t4& 0 —r&A01" C&A
• Contractor-(ss)):
Business Name: N!9'9uCTi0C4
Contact Name(s):
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email: ? t4LG��
• Architects En gineer s :
Business Name: Uft V1A
Contact Name(s):
Mailing Address, C/S/Z: S
Cell Phone: ( Land Line: e)
EmailbtA tl l AmS e0 LUAkMS WQ6d9U,,U My
Contact Person for Building & Code Compliance: Pie 17 *Y-m
Cell Phone: ( ) .-2-z2 .1,9,70 55 Land Line:
Email: UQ.I rz%P5 @.6-AAAa,,caa
Town of queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
PROJECT INFORMATION:
TYPE: Commercial Residential ! Or\)
WORK CLASS: d
Single-Family —Two-Family Multi-Family (#of units )
Townhouse Business Office Retail
Industrial/Warehouse _Garage (#of cars ) _Other (describe )
ADDITION SQUAB FOOTAGE: ALTERATION SQUARE FOOTAGE:
r-
1st floor: 1st floor: s� o
211 floor: 2"d floor:
3rd floor: 3rd floor:
411 floor: 41h floor:
Total square feet: Total square feet: 1"
ADDITIONAL PROJECT INFORMATION: t�
1. Estimated Cost of Construction: $ 30, 0 /—
2. If Commercial project, what is the proposed use:
3. Source of Heat (circle one): Gas Oil ropane Solar Other
Fireplaces need a separate Fuel Burning Appliances &Chimney Application
4. Are there any structures not shown on the plot plan? YES OQxplain:
5. Are there any easements on the property? YES NO
6. SITE INFORMATION:
a. What is the dimensions or acreage of the arcel? 1 ,-4
b. Is this a corner lot? YES NO
c. Will the grade be changed as a result of the constructio ? YES NO
d. What is the water source? PUBLIC RIVATE
e. Is the parcel on SEWER or a PRIVATE SEPTIC syste . �((C,
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
DECLARATION:
1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:7
PRINT NAME: tJrtS�c�CL\� ��c
SIGNATURE: _ ,��C /�, DATE:
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
Generated by REScheck-Web Software
Compliance Certificate
Project TODD YOUNG-559 LOCKHART MNT RD D
Energy Code: 2015 IECC OE C. E IV
Location: Warren County, New York TOWN OF QUEENSBURY
Construction Type: Single-family COMMUNITY DEVELOPMENT
Project Type: New Construction
Orientation: Bldg. faces 270 deg. from North
Conditioned Floor Area: 0 ft2
Climate Zone: 6 (8499 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
559 LOCKHART MOUNTAIN RD. TODD YOUNG LYNN DELUREY
LAKE GEORGE, New York 12845 17500 GULF BLVD UNIT 207 WILLIAMS&WILLIAMS DESIGNERS
REDINGTON SHORES, Florida 37308 509 GLEN STREET
973-283-2074 GLENS FALLS, New York 12801
TYOUNG@TRIMARK.COM 518-798-4687
LYNN@ W ILLIAMSANDW ILLIAMSDESI
GNERS.COM
Compliance: Passes using UA trade-off
Compliance: 0.0%Better Than Code Maximum UA: 49 Your UA: 49
The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Assembly or Cavity Cont. UA
Ceiling: Cathedral 676 38.0 0.0 0.027 17
Skylight: Wood Frame, 2 Pane w/Low-E 45 0.470 21
Wall:Wood Frame, 16in.D.C. 82 30.0 0.0 0.049 4
Orientation: Right side
Wall:Wood Frame, 16in.D.C. 82 13.0 0.0 0.082 7
Orientation: Left side
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Lynn Delurey- Designer >az 5/9/17
Name-Title 5IVature Date
239.18-1-4 RC-000255-2017
Young, Todd
559 Lockhart Mountain Rd.
Residential Alteration 560 s.f.
Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 1 of 9
CREScheck Software Version 5.5.0
�J( Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified# Pre-Inspection/Plan Review Value Value complies? Comments/Assumptions
&Re .ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR111 energy code compliance for the
U, building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
_construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate El Does Not
403.7 energy code compliance for
[PR311 lighting and mechanical systems. ❑Not Observable
y, Systems serving multiple []Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr_ Btu/hr []Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: []Not Observable
1aManual J or other methods Btu/hr_ Btu/hr_
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 12'.1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3)
Project Title:TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 2 of 9
Section
# Foundation Inspection Complies? Comments/Assumptions
& Req.ID
303.2.1 A protective covering is installed to ❑Complies
[FO11]2 protect exposed exterior insulation ❑Does Not
and extends a minimum of 6 in. below ❑Not Observable
grade. ❑Not Applicable
403.9 Snow-and ice-melting system controls ❑Complies
[FO12]2 installed. ❑Does Not
M) []Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title:TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value value Complies? Comments/A
& Reg.
ssumptions
303.1.3 U-factors of fenestration products ❑Complies
[FR4]3 are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
taken from the default table.
❑Not Applicable
402.1.1, Skylight U-factor. U-_ U-_ ❑Complies See the envelope Assemblies
402.3.3, ❑Does Not table for values.
402.3.6,
402.5 []Not Observable
[FR5]1 ❑Not Applicable
0
402.4.1.1 ,Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable
or has Infiltration rates per NFRC
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate 252.0 cfm ❑Not Observable
leakage at 75 Pa.
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >= ❑Not Observable
R-6 where< 3 inches.Supply and
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>=3 inches and R-4.2
for<3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. []Does Not
�i ❑Not Observable
❑Not Applicable
403.4 1 HVAC piping conveying fluids R- R- ❑Complies
[FR1712 :above 105 QF or chilled fluids ❑Does Not
j below 55 QF are insulated to>_R- []Not Observable
13. ❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]' piping. E1 Does Not
0 F_-]Not Observable j
❑Not Applicable
403.5.3 Hot water pipes are insulated to R-_ R- :❑Complies
[FR18]2 >_R-3. []Does Not
41 ❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR1912 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title:TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 4 of 9
11 High Impact(Tier 1) 2a Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 5 of 9
Section Plans Verified Field Verified
# Insulation Inspection
& Req.ID I I
Value Value Complies? Comments/Assumptions
303.1 All installed insulation is labeled ❑Complies
[IN1312 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value.If this is a R- R-_ ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/z of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
a requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions
& Re .ID Value Value Complies? Comments/Assumptions
402.1.1, Ceiling insulation R-value. R- R-_ ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood
Wood ❑Does Not table for values.
402.2.2,
402.2.6 ❑ Steel ❑ Steel ❑Not Observable
[Fill' ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
ft'. [-]Not ft'. Not Observable
❑Not Applicable
402.2.3 I Vented attics with air permeable ❑Complies
IFI2211 ;insulation include baffle adjacent ❑Does Not
to soffit and eave vents that ❑Not Observable
j extends over insulation.
-� ❑Not Applicable
402.2.4 ,Attic access hatch and door R-_ R-_ ❑Complies
[FI311 Insulation>_R-value of the ❑Does Not
adjacent assembly.
[]Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 = ❑Complies
[FI17]1 .ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8.
[]Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air []Not Observable
handler @ 25 Pa.For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cm/100 cfm/100 ❑Complies
[FI27)1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total - [:]Not Observable
leakage measured with a
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[FI2411 by manufacturer at<=2%of ❑Does Not
design air flow.
[-]Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[FI9]� installed for control of primary ❑Does Not
heating and cooling systems and ❑Not Observable
initially set by manufacturer to
code specifications. - ❑Nat Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls. ❑Not Observable
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 7 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system ❑Complies
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI2612 through one-or two-pipe heating ❑Does Not
systems have outdoor setback ❑Not Observable
control to lower boiler water
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F12812 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
_no demand for hot water exists. _
403.5.1.2 Electric heat trace systems ❑Complies
[F12 9]2 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically []Not Observable
adjust the energy input to the
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[F130]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated []Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system.Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1049F.
403.5.4 Drain water heat recovery units ❑Complies
[FI3112 tested In accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units <2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[FI611 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. [-]Not Observable
Does not apply to low-voltage
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[FI2311 no continuous pilot light. ❑Does Not
9 ❑Not Observable
❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 LowImpact(Tier 3)
Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 8 of 9
section Plans Verified Field Verified
# Final Inspection Provisions Value Value t:omplies? Comments/Assumptions
& Re .ID
401.3 ;Compliance certificate posted. ❑Complies
[F]7]2 ❑Does Not
❑Nat Observable
[]Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F]18]3 mechanical and water heating 1-]Does Not
systems have been provided. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17
Data filename: Page 9 of 9
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 30.00
Below-Grade Wall 0.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door
Window
Door
Skylight 0.47
Heating &Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
:... • C . 11.): f 1 In rLJJ:�Y tl�r•Jfr�u. \ ,•
Orarr .o.YV: - J•,_Je, � � Jr- u . .(•a<A rr < t � eJJ:.•J• : T` l�
t '
L
[�om�
8ol A� s
w Lu
co q •: q-
<; ,
' Jam• p o-+�� �`.
•�;.a 9,S-� - �_I � �
.r✓.err �--
1 � ..... .._.. � I.P.S.
PkP OV A SURVEY MADE FCR
D4VId- E3 ..
�e ------- Y may, a _U_O_G l
[>r '•. i TOWN OF po3a N*%j GY WATR[M COUNTY,N.Y
SC
ALE• �w. sp•---- DATE. JLf1+2 24 1976
JO H h B. VAN DUSEH
t L{- LAND SURVEYORS.GLENS FALLS,N.Y.
' a 1.►S.• IRON PIPE SET
LP,F.2IRON PIPE FOUND '