Loading...
RC-000255-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000255-2017 Date Issued: Friday, June 8, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000255-2017 has been completed. Tax Map Number: 239.18-1-4 Location: 559 LOCKHART MOUNTAIN RD Owner: Todd Young Applicant: Patrick Burke This structure may be occupied as a: Residential Interior Alterations Living Room and Kitchen 560 sq. ft. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 �- Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000255-2017 Tax Map No: 239.18-1-4 Permission is hereby granted to: Patrick Burke Construction For property located at: 559 LOCKHART MOUNTAIN RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Todd Young Single Family-Alteration $30,000.00 Owner Address: 17500 Gulf BLVD,207 Total Value $30,000.00 Redington Shores,FL 33708 Contractor or Builder's Name/Address Electrical Inspection Agency Patrick Burke Construction 936 Bay RD Queensbury,NY 12804 Plans&Specifications Residential Interior Alterations Living Room and Kitchen 560 sq.ft. $84.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,May 30,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the exp. tionAdateky � Dated at the Town of ueensb {/ /(ues0,2017 SIGNED BY: (�M�_a"V �(� for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only /�� ADDITION/ALTERATION PERMIT Permit#: � OG APPLICATION Permit Fee: $ — Vo;%n of(Zccnsburn p 742 Bay Road,queensbury,NY 12804 Invoice#: f Y C�-� OL ' P:518-761-8256 w�ww.gueensbury.net Project Location:rJ{r �7 I (emu=HEART mo(9i Tax Map ID #: Z7l0�� �`C Subdivision Name: CONTACT INFORMATION: • Applicant: TOWN OF QUEENSBURY Name(s): WUNITY DEVELOPMENT Mailing Address, C/S/Z: Cell Phone: Land Line: �) Email: MI-I/$ 911641Z C+. -MAIG. CONIC Primary Owner(s): Name(s): Mailing Address, C/S/Z: Cell Phone: (qZ'1) )2&?9i - 20-74 Land Line: Email: 'T!:JQV t4& 0 —r&A01" C&A • Contractor-(ss)): Business Name: N!9'9uCTi0C4 Contact Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: Email: ? t4LG�� • Architects En gineer s : Business Name: Uft V1A Contact Name(s): Mailing Address, C/S/Z: S Cell Phone: ( Land Line: e) EmailbtA tl l AmS e0 LUAkMS WQ6d9U,,U My Contact Person for Building & Code Compliance: Pie 17 *Y-m Cell Phone: ( ) .-2-z2 .1,9,70 55 Land Line: Email: UQ.I rz%P5 @.6-AAAa,,caa Town of queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 PROJECT INFORMATION: TYPE: Commercial Residential ! Or\) WORK CLASS: d Single-Family —Two-Family Multi-Family (#of units ) Townhouse Business Office Retail Industrial/Warehouse _Garage (#of cars ) _Other (describe ) ADDITION SQUAB FOOTAGE: ALTERATION SQUARE FOOTAGE: r- 1st floor: 1st floor: s� o 211 floor: 2"d floor: 3rd floor: 3rd floor: 411 floor: 41h floor: Total square feet: Total square feet: 1" ADDITIONAL PROJECT INFORMATION: t� 1. Estimated Cost of Construction: $ 30, 0 /— 2. If Commercial project, what is the proposed use: 3. Source of Heat (circle one): Gas Oil ropane Solar Other Fireplaces need a separate Fuel Burning Appliances &Chimney Application 4. Are there any structures not shown on the plot plan? YES OQxplain: 5. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the arcel? 1 ,-4 b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the constructio ? YES NO d. What is the water source? PUBLIC RIVATE e. Is the parcel on SEWER or a PRIVATE SEPTIC syste . �((C, Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above:7 PRINT NAME: tJrtS�c�CL\� ��c SIGNATURE: _ ,��C /�, DATE: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 Generated by REScheck-Web Software Compliance Certificate Project TODD YOUNG-559 LOCKHART MNT RD D Energy Code: 2015 IECC OE C. E IV Location: Warren County, New York TOWN OF QUEENSBURY Construction Type: Single-family COMMUNITY DEVELOPMENT Project Type: New Construction Orientation: Bldg. faces 270 deg. from North Conditioned Floor Area: 0 ft2 Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 559 LOCKHART MOUNTAIN RD. TODD YOUNG LYNN DELUREY LAKE GEORGE, New York 12845 17500 GULF BLVD UNIT 207 WILLIAMS&WILLIAMS DESIGNERS REDINGTON SHORES, Florida 37308 509 GLEN STREET 973-283-2074 GLENS FALLS, New York 12801 TYOUNG@TRIMARK.COM 518-798-4687 LYNN@ W ILLIAMSANDW ILLIAMSDESI GNERS.COM Compliance: Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum UA: 49 Your UA: 49 The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. UA Ceiling: Cathedral 676 38.0 0.0 0.027 17 Skylight: Wood Frame, 2 Pane w/Low-E 45 0.470 21 Wall:Wood Frame, 16in.D.C. 82 30.0 0.0 0.049 4 Orientation: Right side Wall:Wood Frame, 16in.D.C. 82 13.0 0.0 0.082 7 Orientation: Left side Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Lynn Delurey- Designer >az 5/9/17 Name-Title 5IVature Date 239.18-1-4 RC-000255-2017 Young, Todd 559 Lockhart Mountain Rd. Residential Alteration 560 s.f. Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 1 of 9 CREScheck Software Version 5.5.0 �J( Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified# Pre-Inspection/Plan Review Value Value complies? Comments/Assumptions &Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the U, building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable _construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate El Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable y, Systems serving multiple []Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr_ Btu/hr []Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: []Not Observable 1aManual J or other methods Btu/hr_ Btu/hr_ approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 12'.1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title:TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 2 of 9 Section # Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 A protective covering is installed to ❑Complies [FO11]2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ❑Not Observable grade. ❑Not Applicable 403.9 Snow-and ice-melting system controls ❑Complies [FO12]2 installed. ❑Does Not M) []Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value value Complies? Comments/A & Reg. ssumptions 303.1.3 U-factors of fenestration products ❑Complies [FR4]3 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.1.1, Skylight U-factor. U-_ U-_ ❑Complies See the envelope Assemblies 402.3.3, ❑Does Not table for values. 402.3.6, 402.5 []Not Observable [FR5]1 ❑Not Applicable 0 402.4.1.1 ,Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 ❑Not Observable or has Infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 252.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= ❑Not Observable R-6 where< 3 inches.Supply and return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. []Does Not �i ❑Not Observable ❑Not Applicable 403.4 1 HVAC piping conveying fluids R- R- ❑Complies [FR1712 :above 105 QF or chilled fluids ❑Does Not j below 55 QF are insulated to>_R- []Not Observable 13. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]' piping. E1 Does Not 0 F_-]Not Observable j ❑Not Applicable 403.5.3 Hot water pipes are insulated to R-_ R- :❑Complies [FR18]2 >_R-3. []Does Not 41 ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 4 of 9 11 High Impact(Tier 1) 2a Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection & Req.ID I I Value Value Complies? Comments/Assumptions 303.1 All installed insulation is labeled ❑Complies [IN1312 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R- R-_ ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/z of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation a requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions & Re .ID Value Value Complies? Comments/Assumptions 402.1.1, Ceiling insulation R-value. R- R-_ ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood Wood ❑Does Not table for values. 402.2.2, 402.2.6 ❑ Steel ❑ Steel ❑Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every ft'. [-]Not ft'. Not Observable ❑Not Applicable 402.2.3 I Vented attics with air permeable ❑Complies IFI2211 ;insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable j extends over insulation. -� ❑Not Applicable 402.2.4 ,Attic access hatch and door R-_ R-_ ❑Complies [FI311 Insulation>_R-value of the ❑Does Not adjacent assembly. []Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 = ❑Complies [FI17]1 .ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air []Not Observable handler @ 25 Pa.For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cm/100 cfm/100 ❑Complies [FI27)1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total - [:]Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. [-]Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]� installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. - ❑Nat Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI2612 through one-or two-pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F12812 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and _no demand for hot water exists. _ 403.5.1.2 Electric heat trace systems ❑Complies [F12 9]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically []Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated []Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI3112 tested In accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units <2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. [-]Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI2311 no continuous pilot light. ❑Does Not 9 ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 LowImpact(Tier 3) Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 8 of 9 section Plans Verified Field Verified # Final Inspection Provisions Value Value t:omplies? Comments/Assumptions & Re .ID 401.3 ;Compliance certificate posted. ❑Complies [F]7]2 ❑Does Not ❑Nat Observable []Not Applicable 303.3 Manufacturer manuals for ❑Complies [F]18]3 mechanical and water heating 1-]Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: TODD YOUNG-559 LOCKHART MNT RD Report date: 05/09/17 Data filename: Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 30.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Window Door Skylight 0.47 Heating &Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments :... • C . 11.): f 1 In rLJJ:�Y tl�r•Jfr�u. \ ,• Orarr .o.YV: - J•,_Je, � � Jr- u . .(•a<A rr < t � eJJ:.•J• : T` l� t ' L [�om� 8ol A� s w Lu co q •: q- <; , ' Jam• p o-+�� �`. •�;.a 9,S-� - �_I � � .r✓.err �-- 1 � ..... .._.. � I.P.S. PkP OV A SURVEY MADE FCR D4VId- E3 .. �e ------- Y may, a _U_O_G l [>r '•. i TOWN OF po3a N*%j GY WATR[M COUNTY,N.Y SC ALE• �w. sp•---- DATE. JLf1+2 24 1976 JO H h B. VAN DUSEH t L{- LAND SURVEYORS.GLENS FALLS,N.Y. ' a 1.►S.• IRON PIPE SET LP,F.2IRON PIPE FOUND '