Loading...
SOLAR-000856-2016 ., TOWN OF QUEENSBURY r 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 je Community Development- Building& Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000856-2016 Date Issued: Thursday, November 1, 2018 This is to certify that work requested to be done as shown by Permit Number SOLAR-000856-2016 has been completed. Tax Map Number: 308.12-1-7.2 Location: 240 LUZERNE RD Owner: Luzerne Holdings Inc. Applicant: Monolith Solar Associates LLC This structure may be occupied as a: Solar Panel System 12, 672 s.f. No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the (""- a,„.,0 4 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 OL Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000856-2016 Tax Map No: 308.12-1-7.2 Permission is hereby granted to: Monolith Solar Associates LLC For property located at: 240 LUZERNE RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Constmction Owner Name: Luzeme Holdings Inc. Solar Panel-Commerical $390,000.00 Owner Address: 169 Haviland RD Total Value $390,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Monolith Solar Associates LLC 444 Washington ST Rensselaer,NY 12144 Plans&Specifications Solar Panel System 12,672 s.f. No Rafter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,June 13,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the ex/P.ration fff date.) Dated at the Town of uecash { / //lues a , e 13,2017 SIGNED BY: /� for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only ACCESSORY STRUCTURE APPLICATION Received DATE ��I I ,'I a.0 Tax Map ID TAX Moa ID Permit No. `cALP(t- - $Gjta -20 t 6 ZONING Permit Feed Rec Fee Ivtvoi� 153 HISTORIC SITE _Yes No Approvals SUBDIVISION NAME 1 Lot#_ JA ,� J APPLICANT D&W Lt 11 Sol,a,►� OWNER tk)"iou I/1�/�'. �r'^ L ADDRESS 444 64 ADDRESS • lata iu q 6T PHONE 41 D • ':;T p .-NU PHONE /f CONTRACTOR -SaMt ('s0 39 111 COST OF CONSTRUCTION(ESTIMATED): $ D' OO O ADDRESS: BUILDING ADDRESS: Rl PHONE: CONTACT PERSON FOR BUILDING& CODES COMPLIANCE PHONE �8. 36 ti-7 lQ (cq TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.ft. 2"'floor sq.ft. Total sq.ft. Height Boathouse with Sundeck Deck Detached Garage(#of cars_) Dock Pole Barn Porch-open QUEENSUR Porch—3 season,Covered,Enclosed BUILDING Shed Other Accessory Structure(s) "Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓1 have read and agree to the above: Print Name: Date: off- 17 f(.I Signature: Date: a 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 STATE OF NEW YORK DEPARTMENT OF STATE FILE COPY ONE COMMERCE PLAZA ANDREW M.CUOMO GovERROR 99 WASHINGTON AVENUE ALBANY,NY 12231-0001 REVIEWED FOR ROSSANA Ro SADO WwW.DOS.NY.GOV SECRETARY OF STATE ENERGY CODE COMPLIANCE ------------------------------------------------ In the Matter of the Petition of:. DECISION MATT STEVENS For a Variance to the New York State Uniform Fire Prevention & Building Code PETITION NO. 2017-0137 Upon the application of Matt Stevens,filed pursuant to 19 NYCRR 1205 on April 5, 2017, and upon all other papers in this matter,the Department makes the following determination: NATURE OF GRIEVANCE AND RELIEF SOUGHT The petition pertains to the installation of solar photovoltaic panels on ten existing self-storage mini- warehouses, approximately 3,000 square feet each in gross Floor area, Occupancy Group S1, Moderate Hazard Storage, 1 story In height, located at 240 Luzerne Road, Town of Queensbury, County of Warren, State of New York. Relief is requested from: Section 605.11.1.3, of the 2015 International Fire Code, providing as follows: Access to systems for buildings...shall be provided in accordance with Sections 605.11.1.3.1 through 605.11.1.3.3 [The petitioner requests relief to install solar photovoltaic system panel arrays without access pathways.] FINDINGS OF FACT 1. Section 605.11.1.3.1 requires a minimum 6 foot wide clear perimeter around the edges of the roof. 2. The existing self-storage buildings are only 15 wide and a 6 foot access pathway around the perimeter of the buildings would eliminate two of three rows of proposed solar photovoltaic panels. 3. It is unlikely that the one story building's roof would ever be accessed by the fire department for smoke venting operations and Section 605.11.1.3.3 allows for panel arrays up to 150 feet in distance in either axis and the proposed installation is 15 feet by 150 feet. TOWN OF QUEENSBURY TOWN OF OUE BUILDING DEPARTMENT Based on our limited examination,compliance BUILDING & ,0 r. with our comments shall not be construed as - ` Indicating the plans and specifications are in Ell I Department Reviewed B1 . full compliance with the Building Codes of oeAOEm°uNln. New York state. of State DaLl: _ Petition No 2017-0137 Page 2 CONCLUSION OF LAW The proposed variance will not substantially adversely affect the Code's provisions for health, safety and security. Strict compliance with the provisions of the Uniform Fire Prevention and Building Code would entail practical difficulties, economic hardship, or would otherwise be unwarranted because such would not achieve it's intended objective or would entail a change so slight as to produce a negligible benefit consonant with the purpose of the code. DETERMINATION WHEREFORE IT IS DETERMINED that the application for a variance from Section 605.11.1.3, of the 2015 International Fire Code, be and is hereby PROPOSED TO BE GRANTED. This DECISION is issued under 19 NYCRR 1206.6. Unless objected to by the petitioner in a writing received by the department the decision shall become FINAL after fifteen days of receipt of the decision by the parties. This decision is limited to the specific building and application before it, as contained within the petition, and should not be interpreted to give implied approval of any general plans or specifications presented in support of this application. �� 4 Jo Addario PE, Director Di sion of Building Standards and Codes DATE:June 12, 2017 MC: nc 308.12-1-7.2 SOLAR-000856-2016 Westside Mini Storage Westside Storage 240 Luzerne Road DEC 2 0 2015 Solar Panel System 12, 672 s.f. 240 Luzerne Road Queensbury, NY 12804 TOWN OF QUEENSBURY GENERAL NOTES LOCATION MAP ay'"i 1. Installation shall comply with the 2015 New York This project consists of the installation of solar modules, per the system description, below. The State Uniform Fre Prevention and Building Code, modules will be installed on a roof mounted nd:mndc 2014 National Electrical Code NFPA 70,the Spnmcmnple.lera racking system and connected to inverters,which A N A requirements of the New York State Public Service convert the photovoltaic output power from DC to 3 Commission (PSC),and the electric utility company. to AC. The solar electric system will be 3 d 2. All electrical components/equipment shall be flobile dVdPA Y 2 momm w enmk interconnected to the utility distribution system listed/labeled by a Nationally Recognized Testing ��, with a new electrical service in accordance with c Laboratory in compliance with NEC Article 110.3. uiaes���.I>: utility specifications. 0 3. All components shall be installed,including wire nd terminations,in accordance with manufacturer's J' m SHEET# SHEET TITLE instructions. / ,, m.� 4. Equipment shall be labeled in accordance with T-1 Tifie Page NEC Article 690. _ STRUCTURAL 5. All DC conductors shall be copper. Project S-1 Parcel Plan 6. All AC conductors shall be aluminum or copper. Location 7. All wires shall be provided with strain relief at all t % So arBQu S-2 Army Layout Plan E z entry into boxes as required by UL resting. dd °clene rmm S lw t,fiwmh 8. Module frames,rail,and posts shall be bonded with m e d equipment grounding conductors. o 9. All GEC connections,taps, and splices shall be AERIAL VIEW made with irreversible compression-type "- ELECTRICAL connectors listed as grounding and bonding equipment, or by exothermic welds E-1 DC/AC Single Une Diagram r 30.All Equipment shat be mounted as shown.Where _ E-2 DC Three Line Diagram a 3 details are not provided,the sub contractor shall E 3 AC Three Line Diagram e use diligent efforts to mount equipment such that it j will be clean, level,and solid. t'., 'I I '� ' E-4 Equipment Pedestal Detail 11. No structural member shall be drilled unless approved by EPC. 12. Conductors shall be re-identified by the following ' color scheme: � DC Positive: Red f SYSTEM DESCRIPTION s DC Negative: Black ' Other conductors shall be in accordance with Project System Ste 390,000 watts DC/300,000 watts AC National Electrical Code. r -? „�,;` Location Inverters (14)SE 20K,(2)SESOK 13. KAIC ratings shall meet or exceed the ratings as shoot i calculated and per utility requirements. Modules (1,200)Trina TSM-PD14 325W Monolith IdentRicotion Westside Storage —� SYSTEM TION .rye y• @,fR+ p'AI�„ '� qct.•,,, ® 90,000 DC/300,000 watts AC �/. TSM-PD14 n. 'fit; � '�'"..� � '�:�, � _ • � , ,. MPI ` tom ` sr . i .'. 3 PHASE UTILITY I`�,. ,� �+ '�-r .4` • t DISTRIBUTION FEEDER }1 - i � _ "PROPOSED PV � � mpg Mpg MP1 'SUB-SYSTEM B n i y I i w 0 § inverter and Ponelboard Pedestal main Sermce meter f1 3 ry -� �k111111 he I et 1 2 11 AZIMUTH=26"DEG,1 DEG TILT MODULES ARRANGED IN PORTRAIT S J r N O I} Imo' I I D D n o � > z5 o N O V O r O T 3 v Vl 1 0 1 W 0 •NY. emµ mM H N .� .• Westside storage Monolith Solar Associates, LLC 240 Luzeme Road 444 Washington Street N '" Queensbury,NY 12804 Rensselaer,NY 12144 ELECTRICAL EQUIPMENT SCHEDULE SHEET NOTES QUANTITY COMPONENT DESCRIPTION 1 600 SOLAR MODULE TRINA TSM-PD14 325 WATT MODULE 1. ALL DC WIRING SHALL BE 1000V 2 306 DC TO DC CONVERTER P700 SOLAREDGE POWER OPTIMIZER RATED. U 3 8 DC DISCONNECT SWITCH NEMA 3R, 1000V RATED DISCONNECT SWITCH 4 8 PV INVERTER [7]SE20K-US, [1]SE10K-US. 480Y/277V AC 2, THE PV SYSTEM IS UNGROUNDED, THE PV SOURCE AND OUTPUT a. 5 1 M.LO.LOAD CENTER 400A,480Y/277V 3PH,NEMA 3R RATED-[7]40A,[l]20A 3-POLE AND[1]15A 2-POLE BREAKER(S) CIRCUITS SHALL COMPLY WITH NEC N 8 1 PV METER VISION STANDARD Xi CLASS 320 PRODUCTION METER 690.35, 7 1 NON-FUSED AC DISCONNECT 400A, 3PH,NEMA 3R, 600V AC-RATED-NON-FUSIBLE 3. MAXIMUM DC OUTPUT CIRCUIT Q a, 8 1 PV GENERATOR AC DISCONNECT 400A,3PH,NEMA 3R, 600V AC-RATED-225A FUSES POWER IS 9,100 WATTS. MAXIMUM 9 1 CELLULAR MODEM-MONITORING OPTCONNECT,5V, 14"X16"PVC ENCLOSURE ALLOWABLE POWER IS 12,750 WATTS. s s p Y 2 O 0 CO C MLO Load OPTIMIZER Center $ SM, 1.2[24]MDdWe, vscoNc c I SUOKo n sm.1.3: wMbtldes soar 5 m2L' s My ve, DC Imerk2 E $Mrp 42[26]MDtlWe, — - - Decomem SUOK .dnr SM 21: MDdWe, w w s rg 3.1: 9 Noddes Dc Imeder3 0 SM.3.Z[26]Moddes . o DDtaxxEm $F2OK o � SM 3A: 2e MDd o smog av z5 Mbdmm kWh kWh C 3 O SE a1[25]Modules � DKCOMHlCI 15F2oK unr j O � T SM l]:[283 MotlWes • Y o aLa'/rl ll`rJ SMN 5.1 26 MDdde, - SM,g 5.2[zs]ModWe, Decoxxecr SMOK5 unr PV NON-RISED AC UTILITY PV GENERATOR SM 5.a: 2e Mndde, DISCONNECT SM,p e.x 5 bbd e, Dc ImerMM MSR METER AC DISCONNECT SM,g 6.2 [28]MDCWes '—� oecoxxeo SFLOK eanr 7 Utility Transformer 8 Sm ea: 5 Mbdde, 6 8 SMrp].l: [2ZswdOdoens dds Oc ImedKv6CONC@LiDr =E p SMrq B.L'12v]Mvtldes —MOL c Imededl zunr $Mlg 8.2[20]Mvtldes v6CONMCI SE10K Monibdng 1 2 3 4 ,un. Cellular 5 Modem y ie H b p $ 6 �_ Shell 4 1 DC/AC SINGLE LINE DIAGRAM ** ER ** E-1 Wire and Conduit Schedule SHEET NOTES Locaiton Size Type ccc Ground Conduit 1.ALL DC WIRING SHALL BE 1000V RATED. A PV SOURCE CIRCUIT 10 AWG [Cu] PV 2 BARE B AWG[Q] FREE AIR 2, THE PV SYSTEM IS UNGROUNDED. THE PV B DC OUTPUT CIRCUIT 10 AWG [Cu] PV 2 10 AWG[Cu]EGC SEE DC CONDUT SCHEME SOURCE AND OUTPUT CIRCUITS SHALL COMPLY U C COMBINED STRING CIRCUIT 8 AWG [Cu] PV 2 8 AWG[Cu] EGC 1'EMT WITH NEC 590.35. -+ N D INVERTER OUTPUT CIRCUIT 8 AWG [Cu] THWN-2 3+N 8 AWG[CU]EGC 1'EMT 3. STRINGS 1 AND 2 SHALL BE COMBINED TOGETHER BY MEANS OF A 1000V DC 30A u RATED Y-CONNECTOR FOR INVERTERS 1-7. A d � 3 g s 1 2 3 4 O O 25 26 "Inveftrs STRING 1.1 « * A + « CO TosEANeEBo i(26 MODULES) " �°°OnHr 2�. a. nSTRING 1.3 « - « + " (28 MODULES) 9 s �em o � STRING 1.2 1 z a ¢ o o zs ze 1 2 8 ¢ o o zT 28 (26 MODULES) + - - - + - + - _ _ _ _ 5 + - * 0 8 A v v A '" o 0 c + t o [ � t 1 2 3 ¢ O O 15 18 0 O 20 ao¢mxxsrsmra e B STRING 8.1 + + + « _ + - + - ) ® TO FAN9BOORDI (20 MODULES) A ___S_ sEESHEErEa s` + ( + Inverter 8 D 9 B STRING 8.2 TYP. s (20 MODULES) �1 DC THREE LINE DIAGRAM **PER SYSTEM** ° SHee 5 E-2 Wire and Conduit Schedule SHEET NOTES Location Size Type CCC Ground Conduit 1.ALL DC WIRING SHALL BE 1000V RATED. D INVERTER OUTPUT CIRCUIT 8 AWG [Cu] THWN-2 3+N 8 AWG[Cul EGC 1'EMT E UNE SIDE LOAD CENTER 4/0 AWG [Cu] THWN-2 3+N 4AWG[Cul EGC RIGID NIPPLE(MAX uh 2. THE PV SYSTEM IS UNGROUNDED. THE PV U SOURCE AND OUTPUT CIRCUITS SHALL � F UNE SIDE NON-FUSED AC DISCONNECT 300 kcmil [AI] XHHW-2 3+N 4 AWG[Cul EGC 3'SCHEDULE 40 PVC COMPLY WITH NEC 690.35. J Ui G UNE SIDE UTILITY METER 300 kcmil [AI] XHHW-2 3+N 4 AWG[Cu] EGC RIGID NIPPLE Q.UX u-) r 3. NATIONAL GRID TO DETERMINE m v S H UNE SIDE FUSED DISCONNECT 300 kcmil [AI] XHHW-2 3+N N/A 3•SCHEDULE 80 PVC SPECIFICATIONS FOR UTILITY METER AND TRANSFORMER. " I MONITORING INPUT CIRCUIT 14 AWG [Cu] THWN-2 2 14 AWG ICU]EGC Y."EMT Q C d roD L M N 9 L d Y � O D MLO Wad Cellar 2 AWG ICU]GEC 0 TOINWRIERS I-1 SEESNED EO// O_O Production E 1\11\11 R E Meter Utility Mehr f� i K Qq o O--oo 1::: N N c ti INWRTwm --_-- - O—ro O�Z] Ij LL L v 2 IN Rmt Itl tTv R II W W d T O—L III e IuvERTrR aA '_"' _ kWhNON-FUSED AC DISCONNECT PV GENERATOR U}Ili{].�� AC DISCONNECT LL I 6 6 Transformer III_ Irl�fG pl-Rn W III I Il_ INVERTER fM k ma'am I 5 1 _ INWRIM*7 I t I____INVERTER NA O iOI SHEEfE 1 9 SEE OHED E--22 6 wcwrta 9 14•R PVC ENaO.OWROSURE t a d F AC THREE LINE DIAGRAM —PER SYSTEM**THREE LINE DIAGRAM —PER SYSTEM** Shed 6 1 E-3 20'-0" v J J 1, 2" I I "T� � d � ua+rp MLO. 0 r ,y nYJ•wam IOMQNfm O ^ wen N C t N Q �a r C � O p 3 "fMWMIECNAMED C O PV MMR C 6'-6" ° CABLE TROUGH CABLE TROUGH - Z-6" a m m N O M d 3 5 o INVERTER PEDESTAL MOUNTED J e a. TO SIDE OF BUILDINGS 5& 10 N NOTES: 1.SEE[E-11 FOR EQUIPMENT SPECIFICATIONS. O a RAMI AC Y4CONNKT a 2. PEDESTAL FOUNDATION CONSISTS OF 8"x 14' URUIY GALVANIZED STEEL RAMMED POSTS DRIVEN TO t Q FXIqMNrrRAnF MErER 8'EMBEDMENT DEPTH BELOW FINISHED GRADE. • e EQUIPMENT PEDESTAL DETAIL Sheet 7 E-4 Mono Multi Solutions I �� THE TALLMAX MODULE I 72 CELL I�IIIll1�) MULTICRYSTALLINE MODULE 310-325W Ideal for large scale installations POWER OUTPUT RANGE • High power footprint reduces installation time and BOScosts -�" • 1000V UL/1000V IEC certified 16.37o MAXIMUM EFFICIENCY / One of the industry's most trusted modules • Field proven performance J 0�+5Vi/ • Strong,reliable supplier POSITIVE POWER TOLERANCE r Highly reliable due to stringent quality control S • Over 30 in-house tests uV,TC.HF,and many morel • In-house testing goes well beyond certification requirements As a leading global manufacturer of • 100%ELdouble inspection nczt generation photovollalc productsr we believe close cooperation with our partners is critical to success.With is local e to prow de undexceptional me Mabe.Trina Certified to withstand challenging environmental is able to provide azceptional service to each customer in each market and conditions supplement our innovalive, reliable • 2400 Po wind load products with the backing of Trina _ • 5400 Pa snow load as a share, bankable partner. We 35 mm hail stones at 97 km/h are commllled in building strat"Ic, rnulually,benofcial collaboration will). - PID resistant installers,devclopois, distributors and other partners as the backbone of our shored success in driving Small Energy Together, Ting Solar limited Comprehensive products and system certificates wwwlrinosolor.rour LINEAR PERFORMANCE WARRANTY - - IEC 61215/IEC 61730/UL 1703/IEC 61701/IEC 62716 - arc, ,mea w.. o:r=s v:,rur-ow<,- - ISO 9001:Quality Management System i.,� w,,,�ry • ISO 14001;Environmental Management System • ISO 14064:Greenhouse Gases Emissions Verification • OHSAS 18001:Occupation Health and Safety Management System �Y LJus c E �•a PV C CLE LISTED Innasolar Smart Energy Together THETALLMAX MODULE TSM-PD14 DIMENSIONS OF PV MODULE ELECTRICAL DATA(STC) unit:mm/Inches Peak Power Walls-P.,(Wp)• 310 315 320 325 IW1m s'Inm Power Output Tolerance-Pm.x(W) 0-+5 -Ig Maximum Power Vollage-W,IV) 37.0 37.1 37.1 37.2 I.." itt ry'. INcbns Maximum Power Current-Imp?(A) 8.38 8.51 8.63 876 Open Circuit Vollage-Voc(V) 45.5 45.6 45.8 45.9 � Short Circuit Current-Isc(A) 8.85 9.00 9.10 9.25 7j y Modal.Efficiency qm(%) 16.0 16.2 16.5 16.8 x 1A !I a� 13 STC lrm,lionce 1000 W/m'.Cell Temperature 25°C.Air MOSSAMI.S. Ten tolerance:x3%. ¢i e• '.� ELECTRICAL DATA(NOCT) I! Maximum Power-Pmuv(Wp) 230 234 238 242 Maximum Power Vollage-Vw,(V) 34.3 34.3 34.4 34.5 ru uawmoxw I - Maximum Power Curren l-Irnvr(A) 6.72 6.83 6.91 7.02 Iwimxa. I Io Open Circuit Vollage-Voc(V) 42.2 42.3 42.5 42.6 Short Circuit Current-Ise(A) 7.15. 7.27 7.35 7.47 NOCT:Imbalance amen t 800 Wftr.Ambient Temperature 20 t 'C.WindSpeed im/s. wsv eanv- MECHANICAL DATA wto sem seolot Solar Cells Malteryslallme 156*156 mm to inches? Cell Orientation 72 cells(6+'121 ' Module Dimensions 1956 x 992.40 mm(77.0-39.1-1.57 inches) Weight 22.5 kg(49.61b) $ Glass 3+2mm(0,13 Inches),High Transmission,AR Coaled Tempered Glass Backsheet White Fan Frame Silver Anodized Aluminium Alloy wlaa. J-8ox IP 67 or IP 68 rated AA Cables Photovoltaic Technology Cable 4.0mm'(0.006 Inches'), 1200 mm(47.2 Inch.,) Connector MC4 Compatible or Amphenol H4/LTX Fire Type Type I or Type 2 I-V CURVES OF PV MODULE(325W) bi TEMPERATURE RATINGS MAXIMUM RATINGS ---_--'-'- --- Nominal Operating CellOperational Temperature -40-+85cC iee --- ---- Temperature JNOCT) 44°C(z2°CI _ Maximum System IOOOV DC(IEC) s Temperature Coefficient of PM+x -0.41%/°C Vollage . IOOOVOC(UL) • - ----- Temperature Coefficlent of Voc -0.32%/°C Max Series Fuse Rating 15A Temperature Coefficient of fisc 0.05%/°C o .e gvwml is is WARRANTY P-V CURVES OF PV MODULE(325W) 10 year Product Workmanship Warranty 25 year Linear Power Warrantyse ' ®w/^' IPwase refer to product woromy for delails) es PACKAGING CONFIGURATION u. -WN\ - Modules per box:26 pieces Modules per 40'container:572 p ecer o ro./anyo.{m^ n .r Trinasol\..11 a2016 TN:o Sol SAFETY AND INSTALLATIONINSTRUCTIONSBEfORE USING THE PRODUCT. CAUTION Trina Solar Limited All IrightsNSTALLATION reserved.Specifications BEFORE N this E PROdatasheetCare subject to change without polka. 5mart Energy Together solar=ee SolarEdge Three Phase Inverters For North America SE9KUS (208V) / SE10KUS (480V) / SE20KUS (480V) a; The best choice for SolarEdge enabled systems — Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance =< — Superior efficiency(98%) - Small,lightweight and easy to install on provided bra ckef' — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Integrated Safety Switch USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us s o I a r • • Three Phase Inverters for North America SE90S (208V)/ SE10KUS (480V)/SE20KUS (480V) SE9KUS SElOKUS SE20KU5 OUTPUT Rated AC Power Output 9000 10000 20000 VA .....................P........................ ...._............................. ........................._........ ................. 0 .............. 1111._1111 Maximum AC Power Output 9000 10000 20000 VA ......................................................... ................................... ................................... ................................... ........... AC Output Line Connections 4-wire WYE(LS-L2-L3-N)plus PE .................... in...........,................ ......._.......................... ............................................... ......................... ...._1111. AC Output Voltage Minimum-Nominal- 105-120-132.5 244-277-305 Vac MaximumblI(L-N) _1111._1111_... ............... 1_111. 1111. . ........ ... ........ .._1111.. ........ 1111._ _... . . ............................ 1111 AC Output Voltage Minimum-Nominal- Maximl(L-L) 183-208-229 422.5-480-529 Vac ......................................................... .......................................................................................................... ........... AC Frequency Min-Nom,Max 59,3;60,;60.5(with HI country setting 57-60-60.5) Hz 1111. .... ... ... . Max Continuous Output Current(per Phase) 25 12 24 A ......... ......... ... .................................. 1111 ....................... .. GFDI Threshold 1 A ......................................................... ........................................................................................................... ........... Utility Monitoring,Islanding Protection, Country Configurable Set Points Yes ;9NPUT r°. l< ,d2z � �* - yl Maximum DC Power(Module STC) 12150 13500 27000 W ................. ................... ................... ................................... ................................... .............................................. Transformer-less,Ungrounded Yes ......................................................... ................................... ....................................................................... .....1111.. Maximum Input Voltage DCto Gnd 250 490 Vdc 1....1 .1 ...1............... .. . Maximum Input Voltage DC+to DC- 500 980 Vdc ..4orn"..................... ..................... .......................................................................................................... . c Nominal Input Voltage DC to Gnd 200 425 Vdc ......................................................... ................................... ....................................................................... ........... Nominal Input Voltage DC+to DC- 400850 Vdc ......................................................... ......................................................................................................... .....1111.. Maximum l npbit Current 26.5 13.5 26.5 Adc ............................. ................................... ................................... ................................... ......1111. Reverse-Polarity ProtectionYes ......................................................... ..........................................................................................................I ........... Ground-Fault Isolation Detection 1100 Sensitivity ....0.............. ........1111................ .._................._..-...-.......................-............_.. ...............91.11............... ........... ..Maximum Inverter Efficiency.....I............... ..............97:1............... ......-1111...98.2............--. ..............98 ................ ....%1111. ................................ CEC Weighted Effciency........................... ..............965............... ................98....,,....,..... ...............98......... �..... ....... ...... Night-time Power Consumption <3 W ADDITIONAL FEATURES - - - Supported Communication Interfaces ,.. RS485,.RS232,Ethernet,ZigB (optional) . Rapid Shutdown .NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit 1s installed�'� STAN DARDCOM PLIANCE i' ;�"''•.' Safety UL1741,UL1699B,UL1998,CSA 22.2 ......................................................... ........................................................................................................... ........... Grid Connection Standards IEEE1547 Emissions FCC part 15 class B '.INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/12-6 AWG ......................................................... ........................................................................................................... ........... DC input conduit size/#of strings/AWG range 3/4"minimum/1-2 strings/12-6 AWG ......................................................... ........................................................................................................... 1111.._... Dimensions(HxWxD) 21 x 12.5 x 10.5/540 x 315 x 260 in/mm ......................................................... ........................................................................................................... .....1111.. Dimensions with Safety Switch(HxWxD) 30.5 x 12.5 x 10.5/775 x 315 x 260 1n/mm ........ .... ......... ....................... _. 1g Weight 73.2/3 3,2 Ib/kg ......................................................... ........................................................................................................... ........... Weight with Safety Switch........................ .............................................. 79.7/36:2............................................... ..Ib/kg... Cooling Fans(user replaceable) .... . ....................................... . .. .......... ......... .. ............ ' )"1 . ... 1111. . ...... ..... . ........... Noise <50 dBA ..eratig'Te'........................................ ..................... .............................401t +6011ve......................................... ...11..11.. Operating Temperature Range -13 to+140/-25 to+60(40 to+60 version available) 'F/-C 1111. .............................. .................... ....................................................................................131 Protection Rating NEMA3R ................................_....................... ....................._..........................._.........._........................................... ........... �^For other n,lpnal seMngs please contact SnlarEdga Support. 0�Rapid sM1uldown kit j SEI"R50--52 for 5E9KUS,SE IWO RSD-53 for 5ESOxUS and SHOWS. in AD—tirnt yj SHK USO28NNUE aM 5EVK-US00BNNUa. iiZ 5Uf15PEE � � ED DcW,11/2014,VOL Subject to changelithe"t�.j 'Dec. 21. 20171 8: 19A MDIA No. 1636 P. 4 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. �that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: West Side Storage Date: 12/08/2017 Occupant: Comm Location240 Luzeme Road OccupancyNon-Residential Queensbury, Warren Co. NY Applicant:r— Monolith SolarAssoc.,LLC -•_ 444 Washington Street Rensselaer, NY 12144; Jose ph A.Holmes. ; ..._....... ....._._ _ _ ' • - - -- - - - - - - - Equipment: -I'- - - - - - - - - - - - - - - - i 'I I 100 -Amp. Service Equipment; #2 -`S-r'vice ConcTudor, 1=10 KVA1-rFansformer, 1 =Feeder ToExisting Panel ..; . '. � •_ , �}moi�' i.r This Certificate applies to the electrical wiring to the electrical equipment listed immediately null and void, This certificate applies only to the use,occupancy and above and the installation Inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,Occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. CienCy or fitiess of the equipment for any particular purpose- This certfficate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department System to which this certificate applies be altered in any way,Including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency. Inc. to initiate the inspection and revalidation any of the components installed as of the above noted date,this certificate shall be process- A fee will be charged for this service. p � CED [E JAN 0 5 2818 101 TOWN OF QUEENSBURY BUILDING&CODES 2Q 1 b Dec. 21. 20171 8 , 19AM MDIA ti'o. 1636 P. MIDDLE DEPARTMENT INSPECI"ION AGENCY, INC. teems&that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: West Side Storage Date: 12/08/2017 Occupant: Solar PV System -System B Location 240 Luzerne Road Occupancy Non-Residential Queensbury, Warren Co. NY Applicant Monolith Solar Assoc.,LLC 444 Washington �. 1 gton Street -;;,�-� •- ,�' _ -~ Rensselaer, NY 12144,,".."', Joseph A.Holmes - - .-- i.. No, - - - - - - - - 141539.3621_3'ZEl_''_ - .�- _ - - - - - - - i - - - - - Equipment: 7 -201000 Watt Inverters; 1 - 10,000�.Watf Invarter,-1_Summing Panel;1=Producibn-Meter; 2 -AC Disconnects; 1 - Utility Meter, 600-Solar Modules This certificate applies to the electrical wiring Eo the electrical equipment listed Immediately null and void. This certificate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownershlp as indicated herein. Upon a change In the use,occupancy or ownership inspection, No warranty is expressed or impliecr as to the mechanical safety,efn- of the property indicated above,this certificate shall be immediately null and void. ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes Invalld based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc, An application for inspection must be submitted to Middle ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc, to initiate the Inspection and revall0ation any of the components Installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. �DE C E 0 V Et 1! JAN (1 701pr JEAN 0TOWN OF QUEENSBUR"Y BUILDING&CODES Dec. 21. 2017 8: 19Ay.@jjlLMDIA No 1636 P• 6 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. that the electrical wiring to the electrical equipment listed below has been examined and is approved'as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: West Side Storage Date' 12/08/2017 Occupant, Solar PV System -System A Location 240 Luzeme Road Occupancy Non-Residential Queensbury, Warren Co. NY Appficant:F � Monolith Solar Assoc. LLC 444 Washington Street _ �y Rensselaer, NY 12144,."" �� -- Joseph A.Holmes No. -- - Equipment.- 7 quipment:7-20,000 Watt Inverters- 1 - 10,000`1N6tt ilnverter;1--Summing Pal ei;-t=ProducR5 ,Meter; 2 AC Disconnects; 1 - I Utility Meter,- 600-Solar Modules , ,. i, i �• !` yam- 'r� This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as Indicated herein. Upon a change in the use,0xupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,effi- of the property indicateo above,This certificate shall be immediately null and void. clency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalldaled upon reinspection by Middle Department System to which this certfficata applies be altered In any way,including but not limit- Inspection Agency, Inc. An application for Inspection must be submitted to Middle ed to,the introduction of adoltional electrical equipment end/or the replacement of Department Inspection Agency. Inc.to initiste the Inspection and revalldation any of the components installed as of the above noted date,this certificate snail be process. A fee wlll be charged for this service, DE JAN TOWN of QUEENS BUILDING&_C0 E