Loading...
CC-000673-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000673-2016 Date Issued: Wednesday, May 3, 2017 This is to certify that work requested to be done as shown by Permit Number CC-000673-2016 has been completed. Tax Map Number: 309.10-149 Location: 75 MAIN ST Owner: Russ Faden Applicant: Russ Faden This structure may be occupied as a:Commercial Interior Alterations 2235 s.f. Subway Restaurant By Order of Town Board Refer to CC-000524-2016 for HVAC,lighting and plumbing schedules TOWN OF QUEENSSBBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000673-2016 Tax Map No: 309.10-1-49 Permission is hereby granted to: Russ Faden For property located at: 75 MAIN ST In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Ross Faden Retail-Mercantile-Alteration $50.000.00 Owner Address: 29 Liz Ann DR Total Value $50.000.00 Saratoga Springs,NY 12866 Contractor or Builder's Name/Address Electrical Inspection Agency Russ Faden 29 Liz Am DR Saratoga Springs,NY 12866 Plans&Specifications Commercial Interior Alterations 2235 s.f. Subway Restaurant Refer to CC-000524-2016 for HVAC,lighting and plumbing schedules $447.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,October 26,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensb before the ex/p'/(anon date J Dated at the Town of ueensb ed e ctober 26,2016 aylF' SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: q /a&-/i6 Permit No. Tax Map ID SO . lO --( -4f P Permit Fee 'IVA aD 0 Zone MAIA >t. Historic? _Yes _✓No Subdivision Name Lot# Site Plan# Subdivision# Project Location 75_ N1o,i l S f TOWN BD.RESOLUTION 86.2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit feels). Primary Owner(s) ��---- S� l�O�en Address a L Phone/Email S( a- l c1 6 _ 1 -7/ 6 - 1 C%deAW_'3_400 . GO." Applicant S Address Phone/Email Contractor Address Phone/Email n Contact Person for Building& Codes Compliance: 2U S S Faden Phone -796- s TYPE OF CONSTRUCTION -/Check all that apply New Addition Alteration 1"floor sf 2°d floor sf Total sf Height Single Family Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile ✓ 22�5 l Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition I J nn II S�-ravrnn�' t`C.'rTnl Source of Heat(circle one) as Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys /V/ Are there structures not shown on plot plan? No Are there easements on the property? S Site Information: a. Dimensions or acreage of lot g b. Is this a comer lot? _Yes _No c. Will the grade be changed as a result of construction _Yes _No d. Public water or Private well (circle one) Public Private e. Sewer or Private Septic System(circle one) Sewe Private Value of all work to be performed (labor or materials) $ 'r7 QZM DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: (`u S S ��QGI a/1 DATE: T�/6 SIGNATURE: `'l/`— DATE: f- For office use only Operating Permit Issued: _Yes _No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 COMcheck Software Version 4.0.4.1 Interior Lighting Compliance Certificate Project Information Energy Code. 2014 New York Energy Conservation Construction Code Project Title: Subway-Exit 18 Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor. Main St. Russ Faden Dennis Rigosu Queensbury,NY 12804 SYVERTSEN RIGOSU Architects Six Chelsea Place Additional Efficiency Package Clifton Park,NY 12065 516-859-2579 Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Dining:cafeteria/fast food 4296 0.90 3866 Total Allowed Watts= 3866 Proposed Interior Lighting Power A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Dining:cafeteria/fast food LED 1:2x2 RECESSED:LED Linear 33W: 1 30 36 1080 LED 2:SM 2x2 SURFACE:LED Panel 36W: 1 2 36 72 LED 3:DOWNLT:LED PAR 17W: 1 6 17 102 LED 4:2 HEAD TRACK:LED A Lamp 9W: 2 2 18 36 LED 5:3 HEAD TRACK:LED A Lamp 9W: 3 1 27 27 LED 6:DECORATIVE PENDANT:LED A Lamp 3.2W: 1 17 3 54 LED 7:DECORATIVE PENDANTT:LED MR 4W: 3 2 12 24 Total Proposed Watts= 1395 Interior Lighting PASSES: Design better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2014 New York Energy Conservation Construction Code requirements in COMcheck Version 4.0.4.1 and to comply with any applicable mandatory requirements listed In the Inspection Checklist. Paul Martin,PE �j�°"- 10/18/16 Name-Title Signature Q Date a Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 1 of 9 COVicheck Software Version 4.0.4.1 Exterior Lighting Compliance Certificate Project Information Energy Code: 2014 New York Energy Conservation Construction Code Project Title: Subway-Exit 18 Project Type: New Construction Exterior Lighting Zone 2(Neighborhood business district) Construction Site: Owner/Agent: Designer/Contractor. Main St. Russ Faden Dennis Rlgosu Queensbury,NY 12804 SYVERTSEN RIGOSU Architects Six Chelsea Place Clifton Park, NY 12065 518-859-2579 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Parking area 4000 ft2 0.06 Yes 240 Driveway 625112 0.06 Yes 38 Illuminated length of facade wall or surface 245 It 2.5 No 612 Total Tradable Watts(a)= 458 Total Allowed Watts= 1070 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp 1 Ballast Lampsl #of Fixture (C X D) Fixture Fixtures Watt. Parkin area(4000 ft2),Tradable Nlattaae LED 2:B:POLE FIXTURE:LED Roadway-Parking Unit 94W: 1 2 81 182 LED 3:C:POLE DOUBLE FIXTURE:LED Roadway-Parking Unit 220W. 1 1 182 182 Driveway 6?5ft2t'Tradable Wattaae LED 1:A:POLE FIXTURE:LED Roadway-Parking Unit 94W: 1 1 91 91 Main en4(6 ft of door width)-Tradable Wattage Other door(not main end 13 ft of door width) Tradable Wattage Illuminated length of facade wall or surfac (245 ft), Non-tradable Wattaae 1 8 11 88 LED 6:CANOPY FIXTURE:Other: LED 5:'D:WALL PACK FIXTURE:LED Panel 70W: 1 1 73 73 LED 7:WALL SCONCE:Other: 1 6 13 78 LED 4:D:WALL PACK FIXTURE:LED Panel 70W: 1 1 73 73 Total Tradable Proposed Watts= 455 Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 2 of 9 ." '�� ti t;y^';` -' 1:,�•]XL:� .-1'�ii��+�IM'C�Y,q�sp gyro-: iv '.i;:'._., Exterior Lighting Compliance Statement Compliance statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2014 New York Energy Conservation Construction Code requirements in COMcheck Version 4.0.4.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Paul Martin, PE 9��� 10/18/16 Name-Title Signature Date tt/5C� .yPMfivy .b a Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server_data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 3 of 9 COMcheck Software Version 4.0.4.1 Inspection Checklist Energy Code: 2014 New York Energy Conservation Construction Code Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # plan Review Complies? Comments/Assumptions I& Re .ID ._.. C103.2 ;Plans,specifications,and/or :❑Complies [PR4]1 :calculations provide all information 1❑Does Not ;with which compliance can be ❑Not Observable; :determined for the interior lighting :and electrical systems and equipment t❑Not Applicable :and document where exceptions to :the standard are claimed. Information :provided should Include Interior ' :lighting power calculations,wattage of; 'bulbs and ballasts,transformers and ' control devices. : C103.2 (Plans,specifications,and/or :❑Complies [13118]1 :calculations provide all information :[]Does Not :with which compliance can be ;❑Not Observable; :determined for the exterior lighting I❑Not Applicable e :and electrical systems and equipment : pP and document where exceptions to :the standard are claimed. Information : :provided should Include exterior ' ;lighting power calculations,wattage of: . :bulbs and ballasts,transformers and control devices. 0406 ;Plans,specifications,and/or ;❑Complies [13119]1 :calculations provide all information Does Not ;with which compliance can be ;❑Not Observable :determined for the additional energy :efficiency package options. ;❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) %-` Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 4 of 9 Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Re .ID I _ C402.2.8 Bottom surface of floor structures ❑Complies 'See the Envelope Assemblies table for values. [FO12]3 incorporating radiant heating ❑Does Not insulated to>=R-3.5. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) '�2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server_data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 5 of 9 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Re .ID C405.2.2. Automatic controls to shut off all OComplies 1 building lighting installed in all ❑Does Not EI-2212 buildings. []Not Observable .❑Not Applicable C405.2.1. Independent lighting controls Installed ❑Complies 1 per approved lighting plans and all ❑Does Not [EL23]' manual controls readily accessible and ❑Not Observable visible to occupants. ONot Applicable C405.2.1. Lighting controls installed to uniformly OComplies C405.2.1. reduce the lighting load by at least ❑Does Not [EL1511 50%. ❑Not Observable. ;ONotApplicabie j Daylight zones provided with ;❑Complies Individual controls that control the UDoes Not lights independent of general area lighting. ;❑Not Observable ❑Not Applicable C4051,3,. Sleeping units have at least one ;❑Complies [ELl,Y.J -.:master switch at the main entry door 1ODoes Not ..,;that controls wired luminaires and `.;switched receptacles. ![]Not Observable ❑Not Applicable ; C405.2.2. ;Occupancy sensors Installed in ;❑Complies 2 :required spaces. j❑Does Not [EL16]1 UNot Observable ❑Not Applicable C405.2.2. ;Primary sidelighted areas are ;❑Complies 3 :equipped with required lighting ;❑Does Not [EL2011 ;controls. ❑Not Observable: ❑Not Applicable C405.2.2. :Enclosed spaces with daylight area OComplies 3 :under skylights and rooftop monitors ;❑Does Not [EL21]1 :are equipped with required lighting ❑Not Observable; controls. j❑Not Applicable C405.2.4 (;Automatic lighting controls for exterior;❑Complies [EL25]' ;Aight[ng Installed. Does Not ❑Not Observable: :[]Not Applicable C405.2.3 ;Separate lighting control devices for OComplies [EL4]1 :specific uses installed per approved :❑Does Not ;lighting plans. ;❑Not Observable ❑Not Applicable C405.3 :Fluorescent luminaires with odd ;❑Complies [EL1913 :numbered lamp configurations that :❑Does Not are within 10 feet center to center(if !❑Not Observable recess mounted)Or are within 1 foot ❑Not Applicable edge to edge(if pendant or surface pP ;mounted)shall be tandem wired. C405.4 :Exit signs do not exceed 5 watts per ;❑Complies [EL611 :face. ;❑Does Not ;❑Not Observable; ❑Not Applicable 11 High Impact(Tier 1) lf,2.4`1 Medium Impact(Tier 2) 3 Low Impact(Tier3) Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Sprserver\spc_server_data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 6 of 9 Section # Rough-In Electrical Inspection Complies? Comments/assumptions & Re .ID I C405.6 'Exterior grounds lighting over 100 W ❑Complies [EL24)' provides>60 Im/W unless on motion []Does Not sensor or fixture is exempt from scope ❑Not Observable of code or from external LPD. ❑Not Applicable C405.2.3 ;Additional interior lighting power ❑Complies [EL8)1 allowed for special functions per the []Does Not 'approved lighting plans and is ❑Not Observable automatically controlled and separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2:. Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc server_data_g\sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 7 of 9 Section --- -------- # Final Inspection Complies? Comments/Assumptions & Re .ID 0408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 30 days ❑Does Not [FI1613 of system acceptance. []Not Observable ❑Not Applicable C303.3, Furnished O&M Instructions for ❑Complies 0408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI1713 representative. []Not Observable []Not Applicable C405.5.2 Interior installed lamp and fixture ❑Complies See the Interior lighting fixture schedule for values. [918]1 lighting power is consistent with what ❑Does Not ;is shown on the approved lighting {❑Not Observable; !plans,demonstrating proposed watts , !are less than orequal to allowed ❑Not Applicable watts. C405.6.2 !Exterior lighting power is consistent VComplies 'See the Interior Lighting fixture schedule for values. [FI1911 :with what is shown on the approved :❑Does Not ! ;lighting plans,demonstrating ! proposed watts are less than or equal !❑Not Observable Ito allowed watts. I❑Not Applicable ; C408.3 !Lighting systems have been tested to !❑Complies [FI33]1 ensure proper calibration,adjustment, 1ODoes Not :programming, and operation. ;❑Not Observable; ❑Not Applicable C408.3 ;Lighting systems have been tested to ;❑Complies [F148]1 !ensure proper calibration,adjustment, T❑Does Not ;programming,and operation: ;❑Not Observable ❑Not Applicable C406 ;Efficient HVAC performance,efficient ;❑Complies [FI3412 :lighting system,or on-site supply of :❑Does Not _ renewable energy consistent with (what is shown the approved plans. ❑Not Observable, ❑Not Applicable ; Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server_data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page Sof 9 Project Title: Subway-Exit 18 Report date: 10/18/16 Data filename: \\Spcserver\spc_server_data_g\Sigma_Psi\16153-subway-tenant-building\Subway-elec.cck Page 9 of 9 FIRE MARSHAL'S OFFICE Tozon of Queensbury 742 Bay Road, Queensbury, NY 12804 " Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Subway 75 Main Street 2235sf, A2 , 62 persons CO-000673-2016 Plan review based on submittals: • Provide layout of exit/ emergency lighting. • Verify FE location and inspection • Verify aisles / Storage requirements • Carbon monoxide detection required • Verify compliant locks / latches— Panic hardware require • Knox Box required on exterior • Truss ID signage required • An automatic fire alarm system is required. Full submittals including a layout, specification sheets for all equipment and appliances is required prior to construction. NOTE: duct detection is not required if HVAC units are under 2000cfm and / or if area smoke detection is in the space and shuts down the HVAC units on activation. 4 -- ---- Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal's Office • Phone: 518-761-8206 • Fa x: 518-745-4437 ffmmarslwl@queensbunl.net • eotozu.queensbunt.net GG - 6-13-Zox10 AIR BALANCE REPORT FORM Name of Establishment w0. Address 7- ml%j o S City 0 ycel s 161,ri� Hood Equipment Manufacturer Installation Contractor Architect_ b eAo_j %__P-i_6 V,5.0 —_-- Air Testing Company _ . _ _ ._ 2 rn ire n T%n r� Equipment Used For Testing t•4AY 0 TOWN OF QUEENSBURY Certification of Air Testing BUILDING &CODES I certify the exhaust and make-up air system(s) have been balanced in accordance with the specifications and/or conditions on the approved plans. Test repo7pr,.ared by- Signature Date TGck CjvQrrtri Make-Up Air and/or HVAC System(s) Required Actual Unit No. Make Model Fan HP Fan RPM Fan CFM Fan RPM Fan CFM / Yrl` / • 5 38-0-0 3JIM 3SZN 3S� c2 Yorr- SG(v%e 1 . 5� 3a/1)' 1S- I *For HVAC units CFM of outside air must be shown. L - - Uni�S 3 + N oLron'fi TA b4aKlied yct A > 4tre'5 no '�tncint {{j� rr GG�4�Mi Z�rs ra-d vn45 I rolJJ,,KS�K6+M ✓prr ,,d Tz-S� . I�OT'1 GrerL rA s{,-((ed (-e\ gc.co rfjAA ct w ITh QAVFI;Ct��r IS rt.C. otwr-c^,W'an3 Make-Up Air and/or HVAC System(s) -Continued OPENING Unit AreaAvg• No. Served No. size Gross Net Measured Velocities FPM CFM Area FV Area F1' Dlfjl j CA Z>1 - il , l (Z g-4 LN IP 3DB 5ldc c ac+r�c r•+ 7 lj UOD Building Pressure ❑ Positive L Negative Pressure in Inches W.G. Barometric Pressure _ Outside Air Temperature Smoke Tested L Yes L No Page 3 :I sr ch, N aicosu ArchiEccis.PLLC Certificate of Substantial Completion Project: Project No.: 839 15 001 Subway Exterior Shell 75 Main Street Queensbury, NY 12804 Contract For: Exterior Shell Only Contract Date: April 2017 To Owner: Russ Faden Date of Issuance: April 28, 2017 Project or Designated Portion Include: Exterior Shell Only The architectural and structural Work performed under this Contract has been reviewed and found, to the Architect's best knowledge, information and belief, to be substantially complete. Substantial Completion is the stage in the progress of the Work when the Work or designated portion thereof is sufficiently complete in accordance with the Contract Documents so the Owner can occupy or utilize the Work for its intended use. The date of Substantial Completion of the Project or portion thereof designated above is hereby established as April 28, 2017 which is also the date of commencement of applicable warranties required by the Contract Documents, except as stated below: Perform a blower door test and submit test report. Syvertsen Rigosu Architects t April 28, 2017 Architect: By: Date: feu 5 > ode„ `l 1.2 Contractor. r By: Date: f-u s 5 �I e, a `/ 42 Owner. By: Date: