Loading...
BOTH-000830-2016 0-01-04hhal. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: BOTH-000830-2016 Date Issued: Thursday, September 21, 2017 This is to certify that work requested to be done as shown by Permit Number BOTH-000830-2016 has been completed. Tax Map Number: 252.48-1-9 Location: 17 TOP OF THE WORLD Owner: Earl Waugh,Top of the World Homeowners Assoc. Applicant: Northern Enterprises General Contracting LLC This structure may be occupied as a: 192 sq.ft. deck (replacement) By Order of Town Board Unit 17 Top of the World Homeowner's Assoc. TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road.Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (5 18)761-8256 BUILDING PERMIT Permit Number: BOTH-000830-2016 Tax Map No: 252.48-1-9 Permission is hereby granted to: Northern Enterprises For property located at: 17 TOP OF THE WORLD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Earl Waugh Deck $22,447.67 Owner Address: 4792 Ridgemoor CIR Total Value $22,447.67 Palm Harbor,FL 34685 Contractor or Builder's Name/Address Electrical Inspection Agency Northern Enterprises 38 Saratoga AVE South Glens Falls,NY 12803 Plans&Specifications 192 sq.R.deck (replacement) Unit 17 Top of the World Homeowner's Assoc. $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,December 13,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Qye7 n esd , e her 3,2016 SIGNED BY: (` 1(/// for the Town of Queensbury. Director of Building&Code Enforcement unu:e use vnry ACCESSORY STRUCTURE APPLICATI - Received DATE 11 4A- lip I Tax Map ID TAxMAP ID 5 - I l Permit No. 6JO`t H- O 301(v ZONING Permit Fee SZ'`% tom-" 1 S19 Rec Fee Hisromc SITE _Yes _No Approvals SUBDIVISION NAME Lot#_ ,J /�1,, �/A APPLICANT w- OWNER GOflf I&lU 7 IUIWIAIAP,�S k5C ADDRESS U.f' ADDRESS 441 lickhaa Mf Rd. ,47 cSb��pltnC1'1� tipl( GEOML Nd 1245V/ir PHONE J16 " �l�y!O-'"ffLsI I"1 /p PHONE (DA- /9(P r �) ll ,_/ ��� $ CONTRACTOR �60-hea) C./ � 6y' L COSTOFCONSTRUCTION(ESTIMATED): $0IJILILl I- l07 ADDRESS: C11111*1,113R I�.UC],JUQ(Lt7✓P BUILDINGADORESS: 44� LOckhfy(f (Yl(- d un,-� I� c5n GI ens +a�l/ls/,�n3 !`aKxGeor�e, N�i IZ946' PHONE: CONTACT PERSON FOR BUILDING&CODES COMPLIAAoe L_UdId)I Q PHONE i100 ' I 70 TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.ft. 0d floor sq.ft. Total sq.fl. Height Boathouse with Sundeck Deck I Detached Garage(#of cars�) Dock Pole Barn Porch-open Porch-3 season,Covered,Enclosed Shed Other Accessory Structure(s) •'Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true &complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. ✓I have read and agree to the above: Print Name: 1 11 Date: a7 a lin Signature: Date: ld/ 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 Engineering America Company 8 Fielding Street Glens Falls, NY 12801 518-615-0201 Georgevas3@vahoo.com June 23,2018 Re: Certification Unit 17—Upper Deck Mr.Waugh ToW Dear Sir: This letter is to certify that the upper deck on Unit 17 was installed in substantial compliance with the drawings provided for this deck as follows: - I am the designer of this deck; - I am personally familiar with the site conditions and in consideration of those conditions the deck was designed in compliance with the current New York State Residential Building Code; - I observed the system being installed during construction; - To the best of my knowledge the system was installed in substantial compliance with the design documents.Any minor changes during construction were discussed between me and the Contractor prior to the field changes being made. If you have any questions regarding these items, please contact me. yltttgtiltl€€/ll7aPtfj,, aS1S''§l,1���t,?JJi�f �f� SincOk`�7P , 4,. �}q bb'. #t1f. W,g,:ski k c 1 n h *11 Georg`m;��ai�'c�� ;k PE rE AUG 2 3 2018 TOWN OF QUEENSBUE Y BUILDING&CQ1 FS Ala.—$&q • 1Q 1 b ������������� .u.�i�ii���.a.e..���.���i� ��.�i��. �� ��� i� au,i�n mweom�i��i�i �i ��e. ..n„�i�,n�ou wun.a,i�,,. i.�uS io .u.......... ����..���,���.�,���.,��� � �,.,�,��ii��., ����.���„i ��.� � �� ���������� �i���� ��� i����. iiu���..0 n., .� i� ���i i�,��. �� i�i,�i���.�u�..������� . � e ��.�.��� ii�i.e ni.u�i,i ,i � ��wxnu.n���,wn�i�i���.�����i u,�� i itle Y, ,i . .i i.i ii a. ;. n.,i,m i.... a„i gni iu ,, .0 ua,iiui ii.mein uan ii imi,aii iirvii ini iun..,.ni u i—_iaenu ieuni eamai iin 6u. iunuu on.0 mi i iew.,m,+u w,,,i�i�i ie,iiiu,eaiinuivaenuunmi.unmwu. � n mumuu i�i,i nm�i niu ��, i�..n. � �� ii �i�i„n o. ��ui ���niumr.nii.0 i T'OWN OF Rev 1 12- . . BI SIGN EENS U Y GY Changes per B1 BUILDING CODES EPS`, ReVi 'Ne By: �� TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination,compliance with our comments shalt not be construed Indicatingt as full comtlance plans and Codes in New York State. ofC �d co FILE Copy 111 co k a 1.. O W Il l c ' % ”/�' ' � "/ iii/�/r///.'Viii / Q-t co Z r��j P-i / 23'-9” ;” ;°'i 23'-9" NOTE. NOTE. C ' 2nd FLOOR DECK 2nd FLOOR DECK 2nd �-loor Deck - Demo Plan ALREADYREMOVED EX_� Exist-in 2nd door Deck ALREADYREMOVED E De 2 I z ° A-1 Scale: 1/4"=1'-0" A-1 Scale: 1/4"=1'-p" HATCHED AREA F- a, Pr-2 Proposed 2nd Floor Deck p 2 4 8 TO BE REMOVED 0 2 4 8 z A-1 Scale: 1/4"=1'-0" r 4-: ► �ci p 2 4 vi -� .., { 8 � N CV CD ® O7 Q m a C LU 4- 0 a 0 r —Q ° °°°•� ° - - 00��00� Lp�jv O N O V��- - OWp O y O.O C N W �•N _O C> 'C N C> UVJ _ - - - O'V N�N "ryl n 47 O 'C av C tA C C L �.— +w > L W Q. O C O e eNed, 0�®t7b0 - c q, - _ ( I fa�a �tlya 0541". 541 L�. *A REVISED 41 QJ :P - In1 N O O d N +'U d+' 'F'ice•' U 41 L 'I''+' N N W0)41 i O O i N O N -C v +1 >— N Q'>— The Client Top of the World Condo Association has requested that the first-floor decks be (IJ �'o a d C v i C v _ �' ' -C 4- i i S O U) N ° S Oi eliminated from the Engineer's, Engineering America Company, drawings and not included in � r� ~ ° au+" " E z" �Z the construction documents submitted for a building permit. The original drawing was DRAWN gy developed based on the original need to replace both the first and second floor decks on this 7t7�iVta ®F G&COD S Y DATE p g� p BUILDING Unit. It is the Engineer's opinion that the first-floor decks should be replaced and not 'just left December 1, 2016 as is , or 'fixed' at the discretion of someone else. PROJECT NO. Inconsideration of the substantial risks to the Engineer in rendering professional services in 100% Drawings 1 6-0097-UI 7For Construction connection with this Project scope change, the Client and the Owner of Units 17 agree to make SHEET NO. no claim and hereby waives, to the fullest extent permitted by law, any Maim or cause of action Deck P1anS of any nature against the Engineer, its officers, employees, agents, or subconsultants, which /� may arise out of or in connection with this Project scope change or the performance by any of Unit 17 A-1 the parties above-named of the services under this Agreement. Scale: 114°= 1'-a' . .. BY •i REVISION Rev 1 11-i-1 ti GY Changes per BI 4 NOTE: (4) SIMPSON HOLD DOWS SHALL BE INSTALLED — (1)AT EACH END AND THE OTHER 2 EQUALLY SPACED ACROSS LENGTH OF DECK G'7 LEDGER BOARD — --i SEE DETAIL 22-A6 SEE DETAIL LO FOR DOWN SPOUT FRAMING SIMPSON OR EQUAL SIMPSON OR EQUAL SIMPSON OR EQUAL SIMPSON OR EQUAL HOLD DOWN HOLD DOWN HOLD DOWN HOLD DOWN SEE DETAIL SEE DETAIL SEE DETAIL act 4 SEE DETAIL \ I I 1 I f I ` o BEAM: 7� csa o GIRDER TRUSS, OR 0 co � TS 12x 4x J, OR C� TS 4x 4x 4" OLMANIZED(2)24-in MICROLLAM LAGS INTO �7 TS 4x 4x 4" PRIVACY WALL /LOCATE INSIDE {SEE NOTE BELOW}OR c� OCATE INSIDE 7- -y / PRIVACYWALL GIRDER TRUSS(SEE G.T.NOTE `®.�•�' STUDS----, SEE DETAIL � ! BELOW) HOUSE WALL �q Uj Z00 1-4 cc Pei P-, W �DOUBLE END JOIST ' DOUBLE D-2 Upper Deck Beam SPECIAL NOTE.END JOIST Scale: 1/4"=1'-0" IF USING A MICROLLAM BEAM w IT CANNOT BE WRAPPED IN 2x8 PT FJ 0 2 4 8 TYVEK, PLASTIC, OR ANY OTHER E- Fr 2 Upper Deck Framing Plan @ 16-in oc MATERIAL OTHER THAN THE U A-2 Scale: 1/4"=1'-0" CEDAR SIDING �(2)2x10 RIM BOARD � o 0 2 4 8 SEE DETAIL SPECIAL G.T.NOTE: z IF A GIRDER TRUSS IS USED IT SHALL BE DESIGNED FOR _ A MAXIMUM DEFLECTION OF 1/3-in UNDER FULL LOAD CONDITIONS. 1 9 CONTRACTOR SHALL PROVIDE MFGR CERTIFICATION THAT THIS CONDITION HAS BEEN MET. k 1 078 Z ,r„ C t X11 O THE AREA DISTURBED TO INSTALL' o �"""' ¢ - THE TS4x4 POST SHALL BE F c� ® 3 ^ REINSULA TED WITH A R-21 S� . Z UNFACED FG INSULATIONco O x LL 18-in ELEPHANT FOOT OR / TS4x 4 ` F 6x16x10"PAD SITS ON EXISTING UNDER SONOTUBE FOUNDATION Il SEE DETAIL 2A ON SHEET A-4 12-in SONOTUBE TO MIN. 48-in BFG 24'-5" v FIELD VERIFY \r ° cL�occ i ` - °oa'�g� >v o a�a �tOw ��tc U "7N Ute' 'Dj _ Owp 0000 CUI ti-0 t0C ar► Foundation Plan o " OV70v QOO y� - 2 e o C O. N fl'C C A-2 Scale: 1/4"=1'-0" v}N v��� s°o rn� - 0 N "mN0 'ti=c_ CL 2�1 2 4 8 w °vv�uu co Oc 0 F--z�n v_ p� ,.v Ow 0– Z— N sl 11114 o VAI /,p• .,� ��S � ?®� �• if, �•® 1/f_ � A A111 y � 4 s{� 1!! N v N d N aad -Uv gid - -0m� +' 41 CU +d, � 414,, N d O X to O N N v U Y d 1 - bn'iS aa, + ° >-- w�>-- 31 +1 Ln-P Ul Ol O d d v 3 C N 3 a IS— O Q--0-P' U E z U +S'Z DRAWN gy DATE December 1, 2016 . PROJECT NO. 100% Drawings 16-0097-Ul71 -r} For Construction SHEET NO. Foundation & Framing Plans Unit .17 A-2 Scale: 1/4"= 1'-0" - - -- �e. BY REVIS Rev 1 1Z + NOTES: GY Changes p SPECIAL NOTES: 1. Shoup the project become delayed for any reason, and - 1. Contractor shall walk through each unit that will be the thne between the beginning of the project and the date receiving a new decks) and observe and cracks or other stamped by the Engineer exceed one (1) year the plans imperfections. The Contractor shall be accompanied on must be reviewed for NYS Code changes by a licensed this walk through by the Owner's representative. Photos NYS Engineer or Architect prior to beginning construction. I I I I I t I I I I I I I I I I I I I I I I I r C l l l l l and notes will be taken and made part of the Construction 2. All construction shall comply with the 2015 Residential I I I I I I I I I I I r i I I I I 1 1 1 I I I I I I I I I Documents. I 1 I ! _ 1 . 1 . 1 . 1 I I Code of New York State and the Energy Conservation _ 2. The Contractor, with the Owner's representative present, Construction Code of New York State. 1 = shall observe and examine the existing rim boards (not the 3. The contractor/owner shall comply with all laws, rules and - - ledger boards) for both the first floor deck and the second ordinances of any public authority bearing on the - floor deck. If they are deemed `unacceptable'by both the performance of the work. Contractor and the Owner's representative, They shall be 4. The contractor is solely responsible for all construction CDremoved and replaced prior to beginning construction of he Il- means, methods, techniques, sequences and procedures decks. and for the coordination of all portions of work. 5. The Engineer is not responsible and is to be held harmlessco by the owner from any claim or suit whatsoever, Including 03 all payments or costs involved arising from or alleged to have arisen from the contractor's work to conform to �-- - ------- _ . . . - _- - -- � - -- ---- design intent. _ - 6. All measurements to be job/field verified and advise 00 Engineer of any discrepancies prior to proceeding. 7. Drawings not to be scaled from for field work purposes. 8. All stairs: - = a. Max rise 8 '4" Z b. Min run 9" _ c. Nose 1 1/8" - - rr, Handrail & Guard Notes: _ 1. Handrails shall be provided on at least one (1) side of _ - each continuous run of treads or flight with four (4) or = more risers. 2. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, shall be not less than -- ----------- -- -- - ------ = y - _ 34-inches and not more than 38-inches. i = 3. 1-landrails foo-stairways shall be continuous for the full E- I I length of the flight, from a point directly above the top Z EXISTING HANDRAIL riser to a point direct) above the lowest riser of the _ & GUARD NOT p y � ' SHOWN flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. 4. Handrail Grip: z- a. Type I. Circular cross section shall have an outside diameter of at least 1-1/4" but not CA-3 North Elevation greater than 2". Scale: 1/4"=1'-0" 5. Guards shall be located on all porches, balconies, NOTE: L IF TREX DECKING IS USED snips or raised floors located 30-in Or more above - IF TREX DECKING IS USED 0 2 4 8 c� \ HIDDEN FASTENERS grade' HIDDEN FASTENERS ARE REQUIRED 6. Guard height shall be not less than 36-inches. ARE REQUIRED RAILING i DECK TO SLOPE s"PERF- ECK TO e PERF- 7. Intermediate rails and spindles shall be placed so as RAILINf- TYPE T.B.D. AWAY FROM HOUSE POST AWAY FROM HOUSE SEE SPECS-� - not to pass a sphere 4-inches or greater. 2x$P.T. BLOCKING c 2x8 P.T. BLOCKING DECKING N CANTILEVER DECKING a; N CANTILEVER TYPE T.B.D. OVER BEAM FLASHING TYPE T.B.D. OVER BEAM FLASHING SEE DETAIL 7 SEE SPECS 8,�, SEE DETAIL 7� 3x1"SLEEPERS SEE SPECS 8' HANGER . 3x1"SLEEPERS HANGER .' - SEE DETAIL 7 General Design Criteria CJ SEE DETAIL 7�'j \ RUBBER OR MOD.BIT ROOFING 1 i a I 2x8 P.T.LEDGER RUBBER OR MOD.BIT ROOFING � --_ _ I I I I fl I I I 1 I I _ ) 1 I 1 2x8 P.T.LEDGER FASTEN PER DETAIL 6 4"PLY OR OSB ----"'� FASTEN PER DETAIL 6 •� 1. Seismic design category-C U 4"PLY OR OSB -"'" DECKING 2x10 P.T. 2. Concrete weathering probability-Severe O DECKING _ - v) c DBL 2x8 BLOCKING RIM BOARD � 3. Design wend speed - 115mph .,� 0 BETWEEN FJ's ;:fit 4. Design ground snow load-60-psf K[ t AT RAILING POST 5. Termite infestation -Slight to moderate LOCATIONS 2nd FLR BEAM SIMPSON OR - . 6. Decay probability-Slight t0 moderate SiMPSON OR ' _ t EQUAL HOLDDOWN TS 12x 4x L OR EQUAL HOLDDOWN - 2" ` � 7. Exposure category-B I WGLMANIZED(2)24"MICROLLAM SEE DETAIL 7 O SEE DETAIL 7, 2x8 P.T. DECK JOIST g 2nd FLR BEAM Z2x8 P.T.DECK JOIST ti OR GIRDER TRUSS 8. Wind-borne region - NO U I." @ 16 in oci ^' TS 12x 4x 2 OR @ 16-in cc EVEN WITHBOTTOM WGLMANIZED(2) 24"MICROLLAM EVEN WITH BOTTOM . Genera!Design Loads '�- OR GiRDER TRUSS OF EXISTING HOUSE FJ OF EXISTING HOUSE FJ 0 Deck Floor Load -60-psf live load plus dead load t O Comma c"!ca#ions: , 0 I Common S e ►f h- P 1. AN lumber shall be SPF#2 or better, and be pressure i treated as follows: a. Posts that maybe iri contact with ground- UC3B Al b. Joists and beams that may be in contact with ground- UC4A 2 20d Floor Deck Laminated Beare - Wolmanized-cannot be site treated ° 3. All concrete shall be 3500-PSI 28-day strength. 4. All tube steel shall be 50,000-psi °2�T° EXISTING 1st FLOOR DECK W° EXISTING 1st FLOOR DECK SEE WAIVER SHEETA-1 a. All other Steel Can be 36,000-psi �N SEE WAIVER SHEET A-15. All foist hangers shall be Simpson GMAX or Simpson oWQ o v v o stainless steel unless otherwise approved by the Design 0_111 v o LZ -C Engineer. a�oa o 0�Z o'3 v 6. All hanger fasteners must be hot dipped galvanized (for > use with GMAX hangers) or stainless (fUJ or use with stainless hangers). 0-Z��-°- C LI 7. Simpson holddowns, DTT!Z, shall be installed at locations o_ i on both lower and upper decks as shown on the drawings. 8. All hangers must be installed in accordance with Q��eea>I Manufacturers specifications for use with pressure treated j� lumber. foAf a. NOTE- the specific hangers maybe different 'n based on the preservative used and the preservative Category. Contractor to verify and - submit cut sheets or lumber end tags-for the �a lumber and the hangers- to Design Engineer prior , , to construction. 9. Flashing cannot be aluminum -must be a material N 0� I E i compatible with the pressure treated preservative used. g 4 v 4 o od0 �,+,, i Abbreviations: d v o d d -8-2 ai U P-T. - Pressure Treated a �^ *' L ' BFG - Below finished Grade v "o C3 d C S 4- i i S O 1 T.B.D. - To Be Determined ~ ° ° *' # DRAWN g , DATE DA-3 Section 3 - Thru Railing PostsSection 7 DecemberScale: 1/2"=1'-0" PROJECT N0. Scale: 1/2"=1'-0" 1 2 4 100% Drawings .16-0097. 0 1 2 4 For Construction SHEET NO. Elevations, Sections, & Notes Unit 17 A Scale: 1/4"= 1'-0" A 0 BY REVISION T Rev 1 12-/-16 GY ^hanges per BI CENTER ROW- CENTER OF BEAM OBJ-3"BOX NAIL BEAM ETHER ° N (1), OR LY BEAM r 1DO NO TUSE FOR 3) OR(4)PLY BEAMS J o 0 0 / o b o 0 0 -1--12"TYPE / (2)2"DIAMETER Ill O ® o f o d o 0 o THROUGH BOLTS 1 WITH WASHERS 0 0 0 o a o 0 0 t O { O O 2" BEAM MUST REST FULLY F ON POST Microlam Beam Assembly Detail 9-A4 P.T.6x6 TYP.POST Scale:N.T.S. �- 03 LO TYPICAL POST AT SPLICE NOT ALLOWED 03 v o CD 03o W 5-A4 Beam to Post Connection] - I & 2 Ply wood Beams z � Scale:N.T.S. A � Z P GALVANIZED LAG BOLTS =3"LONG-PREDRILL STEEL p 2x6 PRESSURE TREATED LEDGER FASTENED TO BEAM ,FLOOR JOIST SITS ON E-� - yp� I TOP-SEE DETAIL 0 3 24 T L J�.T.2x6 � o -TUBE BEAM TUBE METAL BEAM / ur; ENDS SEALED PRIMED -w ter- TS 4x 4x Q" -�r�TS 4x 4x 4" Z FOUR ANCHORA-EVELING L, FOR ANCHOR/LEVELING "DIA ANCHOR/LEVELING Sx 12x 2"STEEL PLATE BOLTS a"DIA ANCHOR/LEVELING 8x 8x z STEEL PLATE BOLTS U ATTACH Wl1"H 1"GALVANIZED BOLTS(4)TYP WELDED TO POST BOLTS(4) TYP - WELDED TO POST TS 4x 4x 4"POST 1 se-r Steel Beam Top Plate Detail z _ . R STAINLESS LAG SCREWS a.. GROUT AFTER__---1'.,, `��+ r- GROUTAFTER� -� - +::..-. Scale:N.T.S. N CAS SHOWN LEVELING O 8x 12x z" LEVELING - 0 8x 8x 2" „ � o o � o '� � STEEL PLATE MIN. 4-in EMBED STEEL PLATE 12„—� MIN. 4-in EMBED 2„ f^�2„_� �TS 4x 4x 4”POST 12-in SONOTUBE O o 0 0 w/(4)#4 VERTICAL REBAR 2”SONOTUBE - FOUNDATION AND#3 REBAR TIES - �_STAGGER FASTERNERS AT 12"oc IN 2 ROWS AS SHOWN 1 s-A4 Ledger Attachment Tb House Scale:N.T.S. 2-A4 Steel Post to Foundation ,Connection 2 A4 Steel Post to Sonotube Connection y Scale:N.T.S. Scale:N.T.S. �--� 10x 4x 2"TUBE i STEEL BEAM POST CAP • C 10"L-4-118"CLEAR INSIDE 0 / 'STEEL O OV. ot o O f ft ^� CAP WELDED X14)i°THRU BOLTS U r -----TO POST-1"WELD-� V�TH WASHERS � [a O � ALL AROUND --�_4x 4x 4"STEEL + POST PRIMED �- -�- `�'tl`, � � �U � NON-CORROSIVE FLASHING { NON-CORROSIVE FLASHING " MIN. 6-in ABOVE HOUSE FLOOR MIN. 6-in ABOVE HOUSE FLOOR SEE DRAWING FOR LENGTH f—�6"—� 17-8 A4 Tube Steel Beam to Steel Column Connection Detail LEDGER- SEE DETAIL 6-A4 V 7 LASHING MIN. 6-in OUT FROM HOUSE LEDGER- SEE DETAIL 6-A4 LASHING MIN. 6-in OUT FROM HOUSE — SIMPSON LUS8 OR EQUAL — SIMPSON LUS8 OR EQUAL Scale:N.T.S, GMAX OR STAINLESS HANGER �GMAX OR STAINLESS HANGER a j ECK JOIST ECK JOIST (2) 24 ML BEAM u i r- 2)#4 REBAR O fWO LMANIZED \�_6-SD#9x1-1/2"SCREWS \,6-SD#9x1-1/2"SCREWS �-•. OR 8-10Dx1 1/2"NAILS OR 8-10Dx1-1/2"NAILS End of Stair Pad Detail 3-A4 OST CAP FOUNDATION OR� IMPSON DTT1Z HOLDDOWN OR Q FOUNDATION OR� HDG LAG WITH HDG WASHER OWN OR EQUAL Scale.N.T.S. NOTE: EQUAL E U 2"�`-�2"�2" 16'H- 161 3-5/8"CLEAR INSIDE 8 HDG LAG WITH HDG WASHER HOUSE WALL e CONCRETE SHALL BE 3500 psi N HOUSE WALL 3-in PENETRATION INTO SILL, 3-in PENETRATION INTO SILL, '�-4"STEEL e ° O €A� TOP PLATE, OR STUD �— TOP PLATE, OR STUD ° CAP WELDED €- -��_f4)2"THRU BOLTS At Holddown Joist Locations At Joists Without Holddowns ° �� WITH WASHERS ° o � N TO POST-1"WELD ooc�2 ��,� a c L�°CC L Of: 4 ALL AROUND 4x 4x 4"STEEL 7_A4 Joist Attachment to House Ledger �N°�U o= _�� POST PRIMED cvN. crm �— Scale:N.T.S. 4 vo 0 0" �c n v° �' oma•-a o E oNoEj 0 -0 13C-0 pq di C) 0,01 NNp 11A-A4 Microllam to Steel Column Connection Detail � 33`N0 2 T�va Scale:N.T.S. - , 10d TREADED NAIL OR ®dad NOMINAL 24 in e #10 WOOD SCREW 2-112"LONG °0���i f-8„-f-16”TYP-s' �IN 2 ROWS 4 �oo A.� GIRDER TRUSS ` • l • ,' f-16" POST CAP • • • • • 2"/-t-?2"-�2"�- 16"H- 16"L- 'XX"CLEAR INSIDE .x-16 TYP "STEEL-SEE TRUSS MFGR � 2"� 3 �a�� I USE THIS OPTION fi � ��e° TRUSS DETAIL FOR WIDTH $USE THIS OPTION FOR _ O ° ALL FJ-BEAM ALL FJ-LEDGER CONNECTIONS rOR ONNECTIONS e v °� ° €� � 4 A4 Wood Beam Assembly Detail � � �� U S CAP WELDED ---1 4)2"THRU BOLTS _ +,w ° iv -TO POST-1"WELD--�' WITH WASHERS °I Scale:N.T.S. C 19 Q P ai a a ALL AROUND °�_(6) 10d NAILS ° aN, �^ a � v�' m�' -\_4x 4x 1"STEEL ' °s° INTO HEADER e � s 3 i i °> Ln i SIMPSON OR EQUAL 4 POST PRIMED H1 OR H5 HURRICANE TIE SEE NOTES BELOW :��(4) 10d NAILS INTO JOIST sc� iasoa° Rt 1Z 0 Q-0 -P U E Z U -P Z A �+ �-+ �-+ SIMPSON OR EQUAL DRAWN gy 11C-A4 Girder Truss to Steel Column Connection Detail � EE NOTNGER DATE SEE NOTES Scale:N.T.S. 8-A4 # Joist to Beam/Ledger Connect Detail December 1, 2016 PROJECT NO. Scale:N.T.S. NOTES:Hangers shall be ZMAX hot-dipped galvanized 100% Drawings 16-0097-U17 connectors For Construction 2.Fasteners(nails)shah be either: --Mechanical galvanized Quick Guard, or SHEET NO. --Hot dipped galvanized Details 3.All holes in hanger must be filled Unit 17 A-4 Scale: 114"= 1'-0" ..• .r ixe „B Y. REVISION , s.. GY Hev 1 12-/-1b hanes r)eg r BI '" ' I �—�PO S T/COLUMN MITERED JOINTS / „�„ EM DRILL&FASTEN WITH AULKED BEFORE TOP OF SONOTUBE �B DECK SELF TAPPING #10 1"LONG PAINTING/STAINING DECK JOIST 2x8 P.T. @ CL @ 24-in oc JOIST � - BLOCK 1x CEDAR LUE&SCREW :. ,",: ,••' ,,+� „ • .. RADE TO STEEL POST D C� 8d GALVANIZED 3 TYP- ALVANI 4 2 8d GALVANIZED � - - NAILS BLOCK TO BE M , PREDRILL WOOD TO DEP TH coNAILS � FILL WITH WOOD PUTTY - 2x8 BLOCK SCREW INSERTED .:` \ �' 4x4 STEEL COLUMN \ \ -4'-'-- AFTER (3) 8d GALVANIZED �� of :t a °°� DECK .',.,';.:. .: NAILS- SEE OTHER DETAIL % PRIMED JOIST _ .• BEAM 'A� CCS 0 � 14-A5 Cedar Covering of Steel Posts Scale:N.T.S. 12-A5 Top of Sonotube To Grade a; Scale:N.T.S. 1�-A5 Blocking Over Beam Scale:N.T.S. z U] P.T. 2x6 r�n G� TOP PLATE "- E-� t1] . U z ° } (3)#4 REBAR O / PINS-EQUALLY 4-in REVEAL CEDAR SPACED Z + RAILING POST (6) 8d GALVANIZED NAILS SIDING MATCH HOUSE 3-FROM ONE SIDE L 3-FROM THE OTHER 2x1 PURLINS @ 24 in oc L ��---GLUE& SHOOT OR SONOTUBE� N,--LEDGER TO ° h•-� HOUSE RIM BOARD j ECK JOIST LUE& SCREW TO BEAM _\ , #4 REBAR TO STICK u GUTTER \__D UP INTO SONOTUBE---. c DOWNSPOUT ECK JOIST _ , 2x1 PURLIN ENTIRE MIN. 4-in — SIMPSON OR EQUAL DBL BLOCKING-INSTALL _ LENGTH OF BEAM FRAME AROUND DOWNSPOUTBEFSIMPSON OR EQUAL HUSC28 2 / DRILL BEDROCK& \_w/P.T. 2x6's TOENAILED WITH HUSC28S HANGER GETNAILS BOARD U HANGER ANGER EACH SIDE OF SS I R DRILL&FASTEN WITH EPDXY#4 REBAR 8d GALVANIZED NAILS INTO GMAX OR STAINLESS BLOCKING INSTALL BEFORE RIM BOARD INTO BLOCKING SELF TAPPING #10-1"LONG� GLUE& SCREW BOTTOM MIN 4 in INTO BEDROCK DECK JOISTS @ CL @ 24-in oc CEDAR PLATE TO STEEL BEAM DBL END JOIST PREDRILL WOOD TO "'DEPTH 22-As Framing Around Gutter Downspout 1$-A5 Blocking Under Railing Posts FILL WITH WOOD PUTTY_J13-A5 Sonotube to Bedrock Detail AFTER SCREW INSERTED MATCH BEAM WIDTH i Scale:N.T.S. Scale:N.T.S. Scale:N.T.S. 15-A5 Cedar Covering of Steel Beam o i' Scale:N.T.S. oxQ p o � EIzz CKING — MODIFIED BITUMEN PLACE LAG SCREW !` 2x1 SLEEPERS ROOFING OR RUBBER OMINALLY CENTER ROOFING rOF DECK JOIST C I PLY OR OSB NOTE: ti.. IZ- ' DECKING PRIVACYWALL_� DO NOT WRAP MICROLLAM ]\-DECK JOIST SHEATHING BEAM IN PLASTIC, Z TYVEK OR ANYTHING 1 O PRIVACY WALL_ e"x 5"GALVANIZED iSTUDS @16 oc LAG SCREW Deck 'Sealing I / `PREIT -DRILL S 1 CE 22-A6 g �.,../ (3)EVENLY SPACE 2x1"PURLINS ' ALONG WALL 24-in oc Scale:N.T.S. /NAIL TO ML i BL END FJ o T N e 4-in REVEAL CEDAR vri .0 1 s-A5 DBL End Joist Attach to Privacy wall SIDING ''°2 —MATCH HOUSE IRDER TRUSS .2,2' c° v a v 6 - LUN�+t.N� -O QL. U . Scale:N.T.S. - / �-0 i v 2x1 PURLIN ENTIRE MINIMUM 1/2"PLY OR OSB OUUJo a 4,,,.9 c o'� ON EACH SIDE OF G.T. � n o ^E / LENGTH OF BEAM o oa'`+ N¢ BOTH SIDES °V1a°��° ;� 0� FPP°111_ RILL&FASTEN IMTH lv o�v'o� "N v'oo 'c - °ELF TAPPING #10-1"LONG CEDAR SIDING �i N 3; ma,v a am @CL@24-inoc �/ ��z�n v� pS;"-u-:o UUJ - UZ� N I� PREDRILL WOOD TO 4"DEPTH FILL WITH WOOD PUTTY AFTER SCREW INSERTED ��rje _CEDAR COVER BOTTOM �° a MATCH WIDTH OF BEAM OF G.T. � c pad' +'(' d Cedar Covering of Girder Truss 1s-A5 Cedar Covering of Microllam Beam 15a-A5 g 2x8 DECK JOIST ° . . � Scale:N.T.S. Scale:N.T.S. v� r ®• .. (3) 10d GALVANIZED NAILS—",., ` . .�Y y� O r�i9�v �r FAC\���av���a 1 a j a v v e v 2x10P.T. mS u w�U a rn� + a � + + RIM BOARD o Q d -°a v -P U -P d O Rim Board to End of Joists o U d � x 20 A5 a U1 NS 7 L L > t! L N N Ul m�' L O O L N O UIS Q � +' ?• v >-• �4'4- 3 •F' Ut i-' UI Scale:N.T.S. su-. L L-C 0 Q) oa, os u#, F- O CL-0i' U E Z U 41 Z DRAWN gy DATE December 1, 2016 PROJECT NO. 100% Drawings 16-0097-U17 { For Construction SHEET N0. Deck Plans Unit 17 A-5 Scale: 1/4"= 1'-0" +.--. __.—_...".. -_ - lilill i i ii II il..I i i i in ii iiva.I4 u i i u u ,uan apil ni ii i I i ,nYlln"ia a Yi, i i i II ly„ iii I iiui i i I -i - - I - ai - I ii imaw l i ii i iieii a iii li i iii i Ir .JYn BY REVISION - Rev 1 12-%16 GY Changes per 81 B SHINGLES TO MATCH HOUSE 1- 15#FELT 2"PLY SHEATHING MATCH PROOF 2x6 RR-MATCH PITCH MATCH FASCIA c SINGLE TOP PLATE � TO EXISTING .•-r W DBL 2x6 MATCH NOMINAL MATCH INSIDE oo LAGAINST HOUSE 3-in CORNER TRIM-\ Lo NAIL TO HOUSE ---CORNER TRIM , X Q `= IWITH EXISTINGLO ° / Z a 2x6 STUD I o SIMPSON OR EQUAL (1) 2x6 @ 24 oc VERTICALLY W W �-- METAL BRACING`� BETWEEN STUDS _ z @ 16-in oc I co -1'-0° ONE SIDE ONLY i. ABOVE BEAM / LINE OF 2nd FLOOR C coo DECK — LOCATION OF w I 2nd FLOOR DECK - - i BEAM -DBL 2x6 PLATE _ TS 12x 4x 2"o�� _ BEAM---'�J (2) 1-3/4 x 24"MICROLLAM 'it _ .. U DBL 2x6 ° AGAINST HOUSE C"J NAIL TO HOUSE SIMPSON OR EQUAL METAL BRACING--,_ 2x6 STUD i W4 ONE SIDE ONLY -�`-@ 16-in oc i , i� - h SEE DETAIL P1-A7A--,,� U) U o "x 10"THRU BOLT LINE OF 1st FLOOR ° 12-in SONOTUBE SIMPSON HUCD610-SDS DECK` rites @ 24"oc VERTICALLY�\ OR EQUAL GMAX OR .' 4'-0' START 6-�n FROM BOTTOM \ _. I ) STAINLESS HANGER 5 TS 4x 4x 2"�-- 2x6 TOP PLATE �'---1 _-- SEE DETAIL 14-A-5 ___ T. 2x6 BOTTOM PLATE M� r- AND DETAIL 2-A4 2)2x10 BOXBEAM #4 REBAR 3-in LEG IN PAD MIN. 6-in EXTEND INTO SONO TUBE SIMPSON GM J610R 12-in SONO ice R EQUAL GM,�X OR TO MIN 48-in BFG STAINLESS HANGER 18-in DIA ELEPHANT FOOT 18-in DIA ELEPHANT FOOT 18-in DIA ELEPHANT FOOT 18-in DIA ELEPHANT FOOT OR 16x16x10"PAD UNDER—�I OR 16x16x10"PAD UNDER OR 16x16x10"PAD UNDER OR 16xl6x10"PAD UNDER SONOTUBES SONO TUBES SONOTUBES SONO TUBES i `, D-7 Privacy Wall Sheathing P-ar Privacy Wall Bracing P-Fr Privacy Wall Framing P-Fr Privacy Wall Elevation S� Sonotube Detail Scale: 1/4"=V--0" A-7 Scale: 1/4"=1'-0" A-7 Scale: 1/4"=1'-0" A-7 Scale: 1/4"=1'-0" A-7 Scale: 1/4"=1'-0" I f � O 05 , I Z 2x6 STUD � 2) 2x6 STUD ON N I z"PLY OR OSB SHEATHING ,--INSIDE OF WALL (� V MATCH EDGE I I TYVEK WRAP / - TS 4x 4x 2"COLUMN O 2 SHEATHING J IN PRIVACY WALL PLY/OSB SHEATHING 4-in HORIZONTAL CEDAR z SILICON CAULK TO FIT WITHIN 1/8-in OF ISIDING i' AROUND JOIST BEAM BEAM-ANYTHING LARGER INTERFACE WILL BE REJECTED 2x6 STUD Q I� SILICON CAULK BETWEEN MATCH EDGE JBEAM AND SHEATHING WITH TS ON ONE SIDE ADD PEAL-&STICK' DRILL OUT SHEATHING FLASHING TO BOTH OA-7 Typical Privacy Wall Construction TO FIT AROUND BOLT __SPACE SIDES OF BEAM& " ACROSS TOP OF BEAM Scale: 1/4"=1'--0" SPACE @ 24 in oc I AT WALL PENETRATION 2nd ROUND OF SILICON VERTICALLY CAULK BETWEEN BEAM AND CEDAR SIDING ` J TS - Wood Stud Connection o - C Scale: 1/4"=1`-0" Y 0,2 FTO o v+ U 2x6 STUD `oWQovo crn�c w'c rn,( c �000. u N 2 N C OA-7 OE Typical Sealing Around Beam 2"PLY OR OS SHEATH/NG \\ EXTEND BACK FLASHING -°oN oo 040:' iVO3 j NO E. -p_ a a TO76-In AFDow Scale: 1/4' -1-0' TYVEK WRAP j o� o� -- I--CAULK BETWEEN FLASHINGS Uj 0 o`vim 0 0 cwt a o r- - 4-in HORIZONTAL CEDAR CAP FLASHING ozw Cr—o_ a;. o �w SIDING POST PRIMED WHERE INSIDE WALL i \IECKING ������ ui� TS 4x 4x POST _EXTEND BACK FLASHING INSIDE WALL-----,,, J TO 3-4"BELOW DBL END JOIST INSIDE WALL 2 2x6 2x6 TOP SIMPSON HUCD610-SDS e LJ ! O \ ---OR EQUAL GMAX OR "- PLATE \\\ STAINLESS HANGER OUTSIDE- 1 2x6 o OA-7 Typ,cal Privacy Wall Flashing Scale: 1/4"=V-0" 3 N i Vp va, a, dv Cc, S i j S L a, o U O a N O a, SIMPSON HUCD610-SDST rn *'-P U 41 L C A GMAX OR STAINLESS HANGER 2x6 PT BOTTOM a Q) C m d .1 w v,� m vi OR EQUAL-BOTH ENDS PLATE d73� N s 3 L Ys > �s a, vV, m+1sooio, o Ln s a, + > v�>- -P 4- 3 +1 m+1 ,n N O d d C a, 3 C aN 3 S 4- L L S O a, N O S a, H O Q-0 +' U £ ZU +' Z STEEL COLUMN PRIMED AND PAINTED[2 COATS] DRAWN gy WHERE EXPOSED � DATE December 1, 2016 j P-2 Bottom Privacy Wall Beam v PROJECT No. 100/ Drawings . 16-0097-U17 A-7 Scale: 1/4"=1'-0" For Construction _ SHEET NO. Privacy Wall ans Unit 17 A-6 Scale: 1/4"= 1'-0" j