Loading...
RC-000840-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (5 18)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000840-2016 Date Issued: Wednesday, May 17, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000840-2016 has been completed. Tax Map Number: 308.12-1-27 Location: 15 WOODEN LN Owner: Michael's Group Homes,LLC Applicant: Michael's Group Homes,LLC This structure may be occupied as a: Single Family Dwelling w/FP 1655 s.f. Garage 466 s.f By Order of Town Board LARIC Development TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforc ent Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (5 18)761-8256 BUILDING PERMIT Permit Number: RC-000840-2016 Tax Map No: 308.12-1-27 Permission is hereby granted to: Michael's Group Homes,LLC For property located at: 15 WOODEN LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michael's Group Homes,LLC Single Family-New $260,000.00 Owner Address: 10 Blacksmith DR, 1 Total Value $260,000.00 Malta,NY 12020 Contractor or Builder's Name/Address Electrical Inspection Agency Michael's Group Homes,LLC 10 Blacksmith DR,1 Malta,NY 12020 Plans&Specifications Single Family Dwelling w/FP 1655 s.f. Garage 466 s.f. LARIC Development $1,300.90 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,January 9,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbu before the a/PJ(rat. date.) Dated at the Town o Queens }/ /J Mo nuary 9,2017 SIGNED BY: a for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLI &C E0 V e Use Onl 8q/ r Date: 12 2 Ib DEC No. 666 wh Tax Map ID SS — — C�C G % 2 ;) i Fee Zone Histc ic9.r RecF e $5 < 00 G SB Ute an# Subdivision Name fat gwy IzAwip— t c B WG& CODE Project Location inion# J I's Irloova.� TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This Is in addition to the permit fee(s). PrimaryOwner(s) MtG►icS Clr�i� µdM�S, L�L-L Address 10 M tTF+ l�+u= —� Mit-'t71 , N,Y IZOZO Phone/Email gkg q,(0 31 l Applicant 3tt Ism �V Address Phone/Email Contractor gp"t as new Address Phone/Email Contact Person for Building&Codes Compliance: Phone IbSl •314 4 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 111 floor sf 21 floor sf Total sf Height Single Family 'i Two-Family Multi-Family (#of units_) Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1,C) 3, 4+) X 4(,,6 r Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition � � rpv�{t�y 1Stp Source of Heat(circle one) a Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys Are there structures not shown on plot plan? Np Are there easements on the property? KO Site Information: a. Dimensions or acreage of lot , b. Is this a corner lot? _Yes -kNo c. Will the grade be changed as a result of construction Yes Z No d. Public water or Private well(circle one) ublic Private e. Sewer or Private Septic System(circle one) Sewerrivate Value of all work to he performed(labor or materials) $ Z 6 0, o 00 DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. S. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree e�to the above: PRINT NAME: f "L J 4o'+ e S U o DATE: /1 7 SIGNATURE: DATE: (L For office use only Operating Permit Issued: _Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application office Use only Received DATE: Tax Map ID TAX MAP ID: Permit No. Permit Fee ZONE: OWNER fvl\GNbet5-S cj zoO JP F-Wmes ,LI.0 PHONE/E-MAIL 7\0,rael cl ,(p311 ADDRESS 10 MA%1 TA I m%4 12010 INSTALLER/ 13er T FIM HE(�.s�11-1 �, PPaC\O PHONE/E-MAIL 510 , 0b9 , ctto00 BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: T. LQCgSC.� PHONE/E-MAIL 5cO • 869 .314 4 BUILDING ADDRESS 15 WOOV4E*A k-M>,G ROOM OF INSTALL: 1..V IA q PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACEINSERT REQUIRED. NOTE: FIREPLACE,FACTORY BUILT* A MANUFACTURER'S FIREPLACE,MASONRY INSTALLATION MANUAL FURNACE(GARAGE ONLY) MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: Her -u-4 o ; Model#: Listed by: y•L.• Number: CHIMNEY INFORMATION Masonry** (check one) _BLOCK —BRICK —STONE Flue _TIE _STEEL _Size in inches Material _DOUBLE WALL _TRIPLE WALL _INSULATED ** If non-masonry provide manufacturer name: ;Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINTNAME: µ�l�o� LO'1'0 DATE: 1 47 (� SIGNATURE: DATE: z b Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: 12�2I►tp Tax Map ID TAX MAP ID: Permit No. Permit Fee ZONE: APPLICANT BSI"&O-C. Cj%zCkA- FWD es' L.L.0 PHONE/E-MAIL Sia .4�C'C1 .(0-,;,11 ADDRESS 10 t3l,ACvLSM�'ll-1 GSLtv�, WAW--TL*] tL�q IwZA INSTALLER/ 04 b.R.t.ES Fet�c1J1-�1 Jyt�t EYClkV/kTl IS[� PHONE/E-MAIL 5t 1b a-1 . 9 3-1 1 BUILDER OWNER MlG1ip.ElS ty1ZCA'O tViFA�S ,t_t..0 5t6 .0yq .b3)1 ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: 7-6tVY LOO NS-U c-�> PHONE/E-MAIL Ia57 .514 4- RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes XNo 1981-1991 Spa or Hot Tub installed _Yes _XNo 1992-Present PARCEL INFORMATION Topography d Flat rolling _Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: VIcA- Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size )oob gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length 1 Sa ft.;Each Trench rV Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: I)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: H go."/ 6+e4 Q' DATE: Z 1,6 SIGNATURE: DATE: Town of Queensbury Building&Cod Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury, NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: 1-Z`-ZA\to Applicant Name: M r✓n e�—1 s Grtzc>�A 1 to►t ,l c Telephone No.: 3tt Address to be Inspected Return Address: 1>at NA111M'Ny .IZOM Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell,Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 1 Window Schedule Calculation Sheet Job Site Address: t5 WpoutN `/�h1� Date: 1Z 1 2)1S, Owner: MtwtrEl.S ey Izew +r,tstt , LLC Application No.: Window#or letter on plan Manu£Name Model/Type Unit or Block# Cell size Rough Opening Width Rough Opening Height Sq. Ft. Vent Sq. Ft. Egress/Clear Opening Clear Opening-width in inches Clear Opening-Height in inches Special Hardware or instruction Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 .oaiv vwofvQ ....YV M „96,8t'-9Z N 80 '6LE n ---- Q C) 0 8 0 oa,/oy Z oy -1 Cy, $ a •bs 8 '9LZbg LZ 107 h \ L9 tbE ` ' cam, 3 „9ti, 8bo9Z S o � p •�o SCS ,5- o r q\ 308.12-1-27 RC-000840-2016 Michael's Group Homes LLC 15 Wooden Lane SFD w/FP 1655 s.f., Garage 466 s.f. REScheck Software Version 4.6.2 C�(J Compliance Certificate N O J d' J (1) 00 Project The Hawthorn °� M Energy Code: 20151ECC D a JE V O Location: Warren County, New York �� CL O) Cf) Construction Type: Single-family DEC i' �U is 7 C Ln � LO co co Project Type: New Construction 0 Orientation: Bldg. faces 180 deg. from North TOWN OF OUEENSBURY n () C Conditioned Floor Area: 1,665 ft2 BUILDING& CODES N N a) 11 r - A Glazing Area 15% LL , � O � Climate Zone: 6 (8499 HDD) � c0 0O Permit Date: 28 November, 201600 U > ❑ Permit Number: CD -- Lr) LL Construction Site: Owner/Agent: Designer/Contractor: 15 Wooden Lane The Michaels Group,LLC Queensbury, NY Malta, NY Compliance: Passes using performance alternative 2 Compliance: 0.5%Better Than Code Envelope Assemblies Assembly Gross r Area Cavity Cont. U-Factor UA Perimeter e Ceiling: Raised or Energy Truss 1,665 0.0 38.0 0.025 42 Walls:Wood Frame, 24"o.c. 625 21.0 0.0 0.056 31 Orientation: Front Entry#1:Solid 21 0.170 4 Orientation: Front 1x Bed#2 (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 SHGC: 0.45 Orientation: Front Mud#20: Solid 19 0.170 3 Orientation: Front Walls: Wood Frame, 24"o.c. 414 21.0 0.0 0.056 15 Orientation: Back 2x Dining (B):Vinyl Frame:Double Pane with Law-E 20 0.300 6 SHGC: 0.45 Orientation: Back Dining #7: Glass 40 0.300 12 SHGC: 0.45 Orientation: Back 2x Great Room (E):Vinyl Frame:Double Pane with Low-E 29 0.300 9 SHGC: 0.45 Orientation: Back Ix Great Room (R):Vinyl Frame:Double Pane with Low-E 27 0.300 8 SHGC: 0.45 Orientation: Back Project Title: The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Pagel of 9 Gross Area Cavity Cont. Perimeter 1x Master Bed (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 SHGC: 0.45 Orientation: Back Walls:Wood Frame, 24"o.c. 441 21.0 0.0 0.056 22 Orientation: Left side 1x Bath(AA):Vinyl Frame:Double Pane with Low-E 5 0.300 2 SHGC: 0.45 Orientation: Left side Ix Home Office(H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 SHGC: 0.45 Orientation: Left side 1x Dining(AF):Vinyl Frame:Double Pane with Low-E 10 0.300 3 SHGC: 0.45 Orientation: Left side Walls:Wood Frame, 24" o.c. 279 21.0 0.0 0.056 15 Orientation: Right side 1x Master Bath(AF):Vinyl Frame:Double Pane with Low-E 7 0.300 2 SHGC: 0.45 Orientation: Right side Basement Walls: Solid Concrete or Masonry 528 0.0 19.0 0.039 21 Orientation: Front Wall height: 7.6' Depth below grade: 6.6' Insulation depth:7.6' Basement Walls: Solid Concrete or Masonry 350 0.0 19.0 0.039 14 Orientation: Back Wall height: 7.6' Depth below grade: 6.6' Insulation depth:7.6' Ix Std Bsmt Win: Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC: 0.45 Orientation: Back Basement Walls:Solid Concrete or Masonry 372 0.0 19.0 0.039 14 Orientation: Left side Wall height: 7.6' Depth below grade:6.6' Insulation depth:7.6' Ix Std Bsmt Win:Wood Frame:Double Pane with Low-E 2 0.300 1 SHGC: 0.45 Orientation: Left side Basement Walls: Solid Concrete or Masonry 236 0.0 19.0 0.039 9 Orientation: Right side Wall height: 7.6' Depth below grade: 6.6' Insulation depth:7.6' 1x 5030 Sliding Window: Wood Frame:Double Pane with Low-E 15 0.300 5 SHGC: 0.45 Orientation: Right side Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements Ii a Scheck Inspection Checklist. F NEtV 2At'611(p Name-Title Signa r G !' Date 06R31�' ti4' k0 - Sit��A Project Title:The Hawthorn Report date: 1128/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 2 of 9 CREScheck Software Version 4.6.2 �(J Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the 0 building envelope.Thermal []Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and I❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACOA Manual S based Btu/hr Btu/hr []Does Not [PR2J2 on loads calculated per ACCA Cooling: Cooling: []Not Observable bJ Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 12.1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 3 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &Re .lD 402.1.1 Conditioned basement wall R- R-_ ❑Complies See the Envelope Assemblies [FO411 insulation R-value.Where interiorR- R- ❑Does Not table for values. Q insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO511 insulation installed per ❑Does Not 0 manufacturer's instructions. ❑Nat Observable ❑Not Applicable 402.2.9 Conditioned basement wall _It _ft ❑Complies See the Envelope Assemblies [FO6I1 insulation depth of burial or ❑Does Not table for values. ,0 distance from top of wall. []Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO1112 to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of 6 in.below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 12°. Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 4 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 ❑Not Observable 0 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U_ U-_ ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3. 402.3.6. ❑Not Observable 402.5 ❑Not Applicable [FR211 0 303.1.3 U-factors of fenestration products ❑Complies [FR411 are determined in accordance j❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal bonier ❑Complies [FR2311 installed per manufacturer's ❑Does Not Qv instructions. ENot Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA MDMA/CSA 101/1.5.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code :❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate s2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 405.2 All ducts in unconditioned spaces R- R-_ ❑Complies [FR2511 or outside the building envelope ❑Does Not are insulated to zR-6. []Not Observable ❑Not Applicable 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not u ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R-_ R-_ ❑Complies [FR17]2 above 105 9F or chilled fluids ❑Does Not below 55 9F are insulated to>_R- ❑Not Observable 3. []Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not 0 ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies (FR191) installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 5 of 9 Section Plans Verified Field Verified # insulation Inspection Value Value Complies? Comments/Assumptions & Re .ID 303.1 All installed insulation is labeled ❑Complies (IN13]2 or the installed R-values ❑Does Not d, provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value.If this is a R- R-_ ❑Complies see the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation IQ requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. j❑Does Not ❑Not Observable ;❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Re .ID 402.1.1. Ceiling insulation R-value. R- ___ R-_ ❑Complies See the Envelope assemblies 402.2.1, E] Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel 402.2.6 ❑ Steel ❑Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every 300 ft'. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F12212 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50=_ ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI411 dm/100 ft2 across the system or ft' ft2 ❑Does Not <=3 cfm/100 ft2 without air []Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [927]1 determine air leakage with ft' ft2 ❑Does Not either: Rough-in test:Total leakage measured with a []Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [92411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Fig]' installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F]10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies (Fl 11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and airflow limits. ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 7 of 9 Section Plans Vered Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.2 Hot water boilers supplying heat []Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI2812 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically tum off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI2912 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the []Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F[30]2 have recirculation pumps that []Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with C5A ❑Does Not 855.1.Potable water-side ❑Not Observable pressure loss of drain water heat recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies (FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI2313 no continuous pilot light. ❑Does Not ,UJ ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Complies (FI7]2 ❑Does Not []Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact frier 3) Project Title:The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 8 of 9 Section Plans Verified Field Verified# Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) f2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/28/16 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\15 Wooden Lane.rck Page 9 of 9 2015 IECC Energy Efficiency Certificate Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass &Door Rating U-FactorSHGC Window 0.30 0.45 Door 0.30 0.45 Heating &Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments i 15 Wooden Lane HVAC Load Calculations for The Michaels Group REVISED �I i i - _ _ C HVAC LOADS ECEOW E j JAN 0 5 20117 D TOWN OF QUEENSBURY BUILDING& CODES Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Tuesday,January 03,2017 l Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac-Rest dential&Light Commercial HVAC Loads- - Elite Software Development,Inc. Appolo Healing Inc. TIEWX 15 Wooden Lane Schenectady,NY 12306 ___ _ Page 2 f.Project Report General Project information Project Title: 15 Wooden Lane Designed By: The Michaels Group Project Date: Friday, December 02, 2016 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data _ Reference City: Schenectady, New York Building Orientation: Front door faces North Dally Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry But Wet Bulb Rel.Hum Rel.Hum Dry But Difference Winter: 1 0.31 n/a rile 70 n/a Summer: 87 72 49% 50% 75 30 Check-Figures: Total Building Supply CFM: 952 CFM Per Square ft.: 0.282 Square ft.of Room Area: 3,377 Square ft. Per Ton: 1,706 Volume(ft')of Cond. Space: 28,714 Building Loads Total Heating Required Including Ventilation Air: 53,427 Btuh 53.427 MBH Total Sensible Gain: 20,649 Btuh 87 % Total Latent Gain: 3,111 Btuh 13 % Total Cooling Required Including Ventilation Air: 23,760 Btuh 1.96 Tons(Based On Sensible+Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer programa Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. t I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\15 Wooden Lane.rh9 Tuesday,January 03, 2017,6:44 AM i Rhvac•Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. - 15 Wooden Lane Schenectady,NY 12306 - - Pae 3 Miscellaneous Re ort System 1 Outdoor Outdoor OutdI6& indoor Indoor Grains In ut Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry_Bulb Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs _ Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.430 AC/hr 0.230 AC/hr 206 CFM 110 CFM Infiltration Actual: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 28.715 Cu.ft. X 28.715 Cu.ft. 12,347 Cu.ft./hr 6,604 Cu.ftdhr X 0.0167 X 0.0167 Total Building Infiltration: 206 CFM 110 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration&Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.430 AC/hr(206 CFM), Construction: Semi-Loose Summer Infiltration Specified: 0.230 AC/hr(110 CFM), Construction: Semi-Loose I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\15 Wooden Lane.rh9 Tuesday, January 03, 2017,6:44 AM i Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Healing Inc. 15 Wooden Lane Schenectady,NY 12306 Page 4 Load Preview Report SysNet SsyAct Duct Scope Ton /Ton Area Gein Gain Gatn Loss CFM CFM CFM Size Building 1.98 1,706 3,377 20,649 3,111 23,760 53,427 703 952 952 System 1 1.98 1,706 3,377 20,649 3,111 23,760 53,427 703 952 952 12x14 Zone 1 3,377 20,649 3,111 23,760 53,427 703 952 952 12x14 1-Dining 154 1,712 170 1.882 4,084 54 79 79 1-5 2-IGIchen 180 1,117 82 1,199 2,752 36 51 51 114 3-Home Office 176 2,090 80 2,170 3253 43 96 96 1-6 4-Bath 1 54 787 41 828 1,162 15 36 36 1-4 6-Bedioom2 198 2,591 582 3,173 6,073 80 119 119 2-4 6-Great Room 389 2,568 126 2,694 6296 83 118 118 2-4 7-Foyer _ 88 834 _75 909 1,949 26 38 38 1-4 84ud Room 44 697 41 638 1,126 15 28 28 1-4 9-Master Bedroom 208 2,809 795 3,604 5A32 66 129 129 2-5 10-WIC 64 601 54 655 1,307 17 28 28 1-4 11$9aster Bath 144 1,475 163 1,638 3,725 49 68 68 1-5 12-Basemenl 1,881 3,468 902 4,370 16,668 219 160 160 2-5 I i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\15 Wooden Lane.rh9 Tuesday, January 03, 2017,6:44 AM i Rhvac-Residential&Light Commercial HVAC Loads _ a - Elite Software Development,Inc. Appolo Heating Inc. 15 WoodenLaneSchenectady NY 12306 Page 5 j Duct Size Preview_ _ Roam or Source MiNmu Maximum Rough. Design SP Ducl Duct Htg Clg Act. Duct Duct Name VeloNy VNociy Factor L/100 Loss Ve4ty Length FM, Flow Fbw Sze System 1 Supply Runouts Zone i 1-Dining Built-In 450 750 0.01 0.1 578.5 541 79 79 1-5 2-Kitchen Built-In 450 750 0.01 0.1 589.9 361' 51. 51 1-4 3-Home Olfm Built-In 450 751 0.01 0.1 490.5 431 96. 96 1-6 4-Bath i Built-In 450 750 0.01 0.1 415.4 151 36. 36 1-4 543edrwm2 Built-In 450 750 0.01 0.1 684.1 801 119 119 2-4 64;matRoom Built-in 450 750 0.01 0.1 678.1 831 116 118 2-4 7-Foyer Built-In 450 750 0.01 0.1 440.4 261 38 38 1-4 8-Mud Room Built-in 450 750 0.01 0.1 315.3 15 f f - 281 28 1-4 9-Master Bedmom Built-In 450 750 0.01 0.1 474.6 661. 129` 129 2-5 10-WIC Built-In 450 750 0.01 0.1 317.4 171. W 28 1-4 11-Master Balh Bulli-In 450 750 0.01 0.1 498.4 491_.._68 68 1-5 12-Basement Built-In 450 750 0.01 0.1 586.1 219 160; 160 2-5 Other Ducts in System 1 Supply Main Trunk Built-in 650 900 0.003 0.1 815.6 703 952- 952 12X14 Summary System 1 Heating Floor: 703 Cooling Flow 952 I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\15 Wooden Lane.rh9 Tuesday, January 03,2017. 6:44 AM Rhvac-Residential$Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc.- - - 15 Wooden:Lane Schenectady NY 12306 ___ _- __ Pa a 6 Total Building Summary Loads Component Area an Cat Sen Total' Description Quan _ toss __Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 201.4 4,307 0 3,201 3,201 Front Door TMG: Door-TMG Entry 21 246 0 82 82 ' Fire Rated: Door-Fire Rated 21 246 0 82 82 12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 1487.3 6,672 0 1,190 1,190 cavity, no board insulation,siding finish,wood studs 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1192 7,484 0 2,007 2,007 cavity, no board insulation,siding finish,wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1696.2 3,043 0 2,072 2,072 Floor(also use for Knee Walls and Partition Ceilings),Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1453.8 11,117 0 1,933 1,933 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 242.4 2,003 0 349 349 on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1681 2,900 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide Subtotals for structure: 38,018 0 10,916 10,916 People: 3 900 1,200 2,100 Equipment: 0 0 0 Lighting: 2040 6,956 6,956 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 206, Summer CFM: 110 15,409 2,211 1,434 3,645 Ventilation:Winter CFM:0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 _ _ 0 143 143 Total Building Load Totals: 53,427 3,111 20,649 23,760 1 Check Figures Total Building Supply CFM: 952 CFM Per Square ft.: 0.282 Square ft. of Room Area: 3,377 Square ft. Per Ton: 1,706 Volume(ft')of Cond. Space: 28,714 Building loads _ - Total Heating Required Including Ventilation Air: 53,427 Btuh 53.427 MBH Total Sensible Gain: 20,649 Btuh 87 % Total Latent Gain: 3,111 Btuh 13 % Total Cooling Required Including Ventilation Air: 23,760 Btuh 1.98 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\15 Wooden Lane.rh9 . Tuesday,January 03, 2017, 6:44 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. • Appolo Heating Inc. <y 15 Wooden Lane' �Scheneciady NY 12306 - _ _ Pa a 20 System 1 Room Load Summary Htg Min Run Run C.Ig Clg' Min Adt Room Area Sens Htg Duct Duet Sens Lat Clg Sys No Name SF Btuh --CFM Size 'Vel Btuh , Bt6h CFM. CFM ---Zone 1-- 1 Dining 154 4,084 54 1-5 579 1,712 170 79 79 2 Kitchen 180 2,752 36 1-4 590 1,117 82 51 51 3 Home Office 176 3,253 43 1.6 490 2,090 80 96 96 4 Bath 1 54 1,162 15 1-4 415 787 41 36 36 5 Bedroom 2 198 6,073 80 2-4 684 2,591 582 119 119 6 Great Room 389 6,296 83 2-4 678 2,568 126 118 118 7 Foyer 88 1,949 26 1-4 440 834 75 38 38 8 Mud Room 44 1,126 15 1-4 315 597 41 28 28 9 Master Bedroom 206 5,032 66 2-5 475 2,809 795 129 129 10 WIC 64 1,307 17 1-4 317 601 54 28 28 11 Master Bath 144 3,725 49 1-5 498 1,475 163 68 68 12 Basement 1,681 16,668 219 2-5 586 3,468 902 160 160 System 1 total _ 3,377 53,427 703 20,649 3,111 952 952 System 1 Main Trunk Size: 12x14 in. Velocity: 816 ft./min Loss per 100 ft.: 0.106 in.wg m Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons I Split Btuh Btuh Btuh Net Required: 1.98 870/b/ 13% 20,649 3,111 23,760 Actual: 2.32 75%/25% 20,850 6,950 27,800 Equipment Data - Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B-* 13ACXN030-230*' Indoor Model: C33-24B+TDR+TXV Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13.5 SEER Sound: 0 0 Capacity: 64,000 Btuh 27,800 Btuh Sensible Capacity: n/a 20,850 Btuh Latent Capacity: n/a 6,950 Btuh AHRI Reference No.: n/a 7620313 CAUsers\nicka\Documents\Elite Software\Rhvac 9 Projects\15Wooden Lane.rh9 Tuesday,January 03,2017, 6:44 AM � .6'uerlaw v�vQ --YV M „9b,8bo9Z N 180 '6LE a 4 � c a bS 8 .9LZb9 > s s LZ 107 w v/ i xto' a0 r�T 19 bb8 - N 3 n9b 8bo97 $ O G N r 308.12-1-27 RC-000840-2016 Michael's Group Homes LLC 15 Wooden Lane SFD w/FP 1655 s.f., Garage 466 s.f. I-NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 2AVz;- May 12,2017 Job #46257 New York State Dept. of Health 77 Mohican Street Glens Falls,NY 12801 RE: Burnt Ridge Subdivision Phase 2 - Queensbury(T), Warren County Lot#27 Septic System— 15 Wooden Lane Gentlemen: This letter is to inform you that we inspected the completed septic system for the house at 15 Wooden Lane (Lot#27) in the Burnt Ridge Subdivision on 5/9/2017. The septic system as installed was for a 3 bedroom house and consisted of a 1,000 gallon septic tank and 150 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, Thomas R. Center Jr., PE cc: Dave Hatin, Town of Queensbury Eric Wilson, The Michaels Group .. .. .,�.,....�...,,.�..•..�...,...W....,.:..,�:W..�.�....W....:.W.....,......,w.......�.._.�,,,:w...�.....�..W.,.�.,...�-...,�,..,w�..-.•..,...W.,...-,.`.-�,�...,Y..,..W....,.,..w,._.w....�..s�.:....W..�W.W,�....._...... W.�.�..W..,,.�..r.......y...-.o�•.............,....,....,..W..�..._.�.Y......•.........,•,.W..�,,.�..,.._.......-......,:.W.,....,.-....-.........-....W-.._�..._ .......,.�..,.w,.....�W...�..,.,...,.._�. _ Map Reference: Map of a Proposed Subdivision Made" For Laric Development, LLC Dated: April 10, 2003 Last Revised: January 04, 2014 By: Van Dusen & Steves Filed: March 03, 2014, Plat C-349 LOT 26 '==G ;, S 25048'45" E 344.61 ' i� LOT 27 !- Area ® .� 1 Lo ° Lar' 36 n 54276.8 ± Sq. FeetNt 1.25 Acres �co window Escape well Electric Meter f 40.0' CC) 1000 GAL. ;��c�u�n°��'st�je'i�nye R;-, .�:�"•, b r SEPTIC TANK 1 5to b Wood Frame — o c�j House WS0 DISTRIBUTION BOX ABSORPTION Ga5 Met — - TRENCHES F 1 3, @ 50° EA. $ n oo y 56 N lYl U • i 379.08' L45„ W i LOT 35 qqlw NQ " I„ 'nom P�9•j��"' 3'T `0!9/'�' 'i�� LOT 28 Legend CB - Catch Basin + y t V ^Yaps W50 > aSil a { - Water Shut Off Valve 1 Q :. Dater May 03;-" 201.x__........-.•.,... � I OL MAP VIOLATION NG A LICENNEDLAND 5UKVMR5 5CAL-15A Map oft12OF litE� 'i J a Survey made for Scale .,..,_..1,•--30 l NEW YORK STATE EDUCATION NAW. j 'ONLY COPIES FROM THE ORIGINAL OF 1,171J SURVEY 1 MARKED WITH AN ORIGINAL OFTHE UWUSUFyEyO� 3 ` O Rosati 5EAL SHALL BE CON51DERED TO BE VAUD TpjjC COPIES.' eN -CERLIFICATION5 INDICATED HEREON 51GNV THAT Richard + 3 TH15 5UKVEY WA5 PREPARED IN ACOGROANR WITH THE - 19 Larid �r�., Ek15TING CODE OF PRACTICr FOR LAND 51 fp Rs pDOPiEp i Jacqueline '� /^°� �y -d}-^�a "�.-,+. 13Y THE NEW YOR5.S AID GEI]FIATIONOr 5-rtf FE551ONLY .,i9 ■ - s 4 4.A LAND SURVEI'ORS.SAID CEKTIFICATIONS°rIPj1 RUN ONLY VM1'iJ "Vll✓JJ M. IJ yorsa TO THE FER5ON FOR WHOM THE SURVEY';PREPARED.ANDON 1115 �� 169 Havilaazd Road LaeeA8blar Ne York I'll EHA FTONHETITLITIMON M,GD`tEr,,ON.NM L Q ns A,y, ew k' 12804 TO ANDLENDING THE ELENDING USTED r1'GN.',AND - m v County, N York - TO THEA551GNEESOFTHELENUINGINSTITL�IGN." Town of Queensbury, Warren 8i®u�Al.y, Srow 1®r^o 1 5112117 SEPTIC AS BUILT 518 ( ) 792--84"74 New York Lac No. 50135 N0. DATE DESCRIPTION DWG. NOR99 2T41-Lot 27 i i Map Reference: �.�• Map of a Proposed Subdivision �� a Made For Laric Development, LLC ' Dated: April 10, 2003 " X ° � 3 Last Revised: January 04, 2014 By: Van Dusen & Steves Filed: March 03, 2014, Plat C-349 LOT 26 rr8 1 ` Lil m . fpr : r S 25048'45" E r ..,.. ..w...W..,.. ..._. ... .._. . „ ....... .. ......_,. _,_,,.., .. ..... ... .... . . ..�.....,. ...,_ _,�._._.� .�_-._...W..�.. . --= W .�._.�.... 8._. ..,. .. "tea , 344.61 ' ;7j LOT 36 Q) Window Escape Well Electric Meter 40,0' 77- LOT LOT 27 511,/7 � rY Area - frame Wood Fr - � 0) 54276.$ - Sq. Feet house �o + WSO'. 1.25 - Acres Mater - N N g i 379,08' N 25048'45" W 3 LOT 35 j y A A� F 1 �V rr I`_ T 'A,T � s '�g :w LOT 28a.-,; ` F�<< Cr tt !yC 8. .fit ..... R :d ,Legend - ff' r w 50135 CB Catch Basin o SccQ LAND - Water Shut Off Valve w .. .... .. ...... „ ..,....,....W.,.. . _ _.,. _........ D ate. . � May 03, 2017 Dus 'UNAUTHORIZED AUCKATION Q"ADDITION TO A 5URVEY Ma� of lYi p $ a Survey made for - Scale 1" 30' OL MAP BEARING AUCCN5ED LAND yUKVEYOR55EALI5A _ - VIOLATION OF 5ECTION 7209,%D-DIV1510N 2,OF THE _ I _ - C�.7'JG1NEW YQM 5TATC EDUCATION LNJ,j - 'ONLY COPICS FROM THE ORJa11LV.OF TH155URVCY - ® d _ _V eMARKED WITH AN ORIGINAL OF Tl IE LAND 5URVEYORS Rosati _ 5rAL 5HALL BE CON5DERCO TQ BG VALIDTRUE COPIES.' ® _ 'CERTIFICATIONS INDICATED HCF.EON5,IGNIFY THAT ? TH155UKVEY WA5 PREPARED 4I I'SCORDANCE WITH THE _ w� Rosati-ep- '''��$''''''jjj''' LXISTING CODE OF PRAOriCE FSR LAND SURVEYORS ADOPTED 7 .s a y i _ IPND'SURVElOR5.E NEW YORK SAID CERIMEAT ONA SHALL RUN - 1 o �J�P...J7 VV SHE l OF 1 _ - TO THE PER50N FOR WHOM Tqg yljiRVEY 15 PREPARED,AN ON HI5 BEHALF TO THE TITLE CC"" i _ ..,.... ............,, F.1PAMf,GOVERNMENTAL �1 'gam County, 7�� qy �j '�j Tjp q = AGENCY AND LENDING IN5TITIJTIUNU5TED HEREON,AND - Town of Queensbury. Warren County, New lurk pn 169 Haviland Road Queensbury, New York 12804 TOTHEA551GNEE50FTHELEHEII;GIN5TITUTION.- R05ATI - - {518) '792--8474 New York Lie. No. 50135 DATE DESCRIPTION DW o NO 27