Loading...
SOLAR-000680-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 -• Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000680-2016 Date Issued: Wednesday, August 23, 2017 This is to certify that work requested to be done as shown by Permit Number SOLAR-000680-2016 has been completed. Tax Map Number: 301.5-1-63 Location: 59 NOBLE WAY Owner: Michael Angelucci Applicant: Michael Angelucci This structure may be occupied as a: Solar Panel System No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the 44t property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: SOLAR-000680-2016 Tax Map No: 301.5-1-63 Permission is hereby granted to: Michael Angelucci For property located at: 59 NOBLE WAY In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Michael Angelucci Solar Panel-Residential $400.00 Owner Address: 59 NOBLE WAY Total Value $400.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Kasselman Solar 20 Walker Way Albany,NY 12205 Plans&Specifications Solar Panel System No Rafter Upgrades $30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,October 5,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbug j?efore the ex4[�/tion Qate. Dated at the Town of ueensb , � r� /-AVed) ctober 5,2016 SIGNED BY: ( 1X V for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only ACCESSORY STRUCTURE APPLICATION Received DATE / J �O 7�I UJ Tax Map ID �— ll�-Q 650 W1 TAX MAP ID 3� I � �'' ��� Permit No. ZONING Permit Fee q � HISTORIC SITE _Yes No Approvals SUBDIVISION NAME Lot# APPLICANT m pz ,, ��1��wt OWNER 1 ADDRESS 6 NCb V_ V (I1�� _ ADDRESS r`AOU (A 01 t� PHONE - PHONEd3- CONTRACTOR i a ,S eMAyn\�d�^`(,�/L� COST OF CONSTRUCTION(ESTIMATED): $ Z ADDRESS: D \N(L,fJI-I� BUILDING ADDRESS: /� _ PHONE: p 0(WSQ-I-� `J ioaSe-, CONTACT PERSON FOR BUILDING&CODES COMPLIANCE 1 PHONE TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1"floor sq.ft. 2ntl floor sq.ft. Total sq.ft. Height Boathouse with Sundeck Deck -— -- -- Detached Garage(#of cars_) ----- - Dock Pole Earn ui Porch-open TOUJNUS'6*. ' N8ISURY +tl ,_ I::J �: J Porch-3 season, Covered, Enclosed - .-_-- •-- — Shed Other Accessory Structure(s) / �Sf 'Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that Uwe are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. p ✓I have read and agree to the above: Print Name: A ��U ��l.t1 , Date: � 2 Signature: l Date: 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 ACCESSORY STRUCTURE APPLICATION (Requirements, Notes, Changes) REQUIREMENTS: 1. Two (2)sets of the following documentation with the application and fee: a) Plot plan drawn to scale with the use of a survey map, if possible (40 scale =40 feet) b) Indicate proposed structure(s), showing setback dimensions from all surveyed property lines c) Show location of all existing structure(s)on the property d) Show location of water supply(well or water lines) e) Show location and configuration of septic disposal system or sewer line. 2. Structural drawings to include: Floor plan; Foundation plan, Cross Sections, Elevations 3. Registered Architect or Engineer's stamp, signed &sealed for residential additionslalterations and any commercial construction costs over$20,000 NoTEs: 1. A permit must be obtained before beginning construction 2. This permit is for any structure other than residential principal structure (house) to include, but not limited to: garage, shed, dock, deck, carport, pole barn, greenhouse, etc. Refer to Informational Brochure No. 3—Accessory Structures — ShedslFences. 3. Changes to Plan — Any changes prior to or during construction will require submittal of amended plans (review and re- approval are necessary) 4. Withdrawn Permits: 20% of the initial fee is retainable by the Town. No fee is refundable after 1 year from initial application date. 5. Additional review: All applications are subject to Zoning Administrator, Code Compliance and Structural Plan Review. CHANGES To RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL): Residential Building Code • New driveway requirements for structures located over 300 feet from main road • Spray foams are allowed to be exposed in rim joist box only, must be covered by 15 minute thermal barrier all other areas; • Protection against decay requirements • Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing over steps • Vent stacks must be 18 inches minimum above roof for all structures New Electrical Requirements • Arc fault breakers required in all habitable spaces for receptacles • GFI protection for all other receptacles in kitchens, bathrooms, garages and unfinished basements • All receptacles must be tamper resistant • Carbon Monoxide detectors must be located within 15 feet of sleeping areas; • All corrugated stainless steel piping must be bonded to the common ground for electrical service New Energy Code • Blower door tests required by credential contractor or structure inspection by air barrier supplier and certified compliant • Programmable thermostats required • Lighting must be 50% energy saving light bulbs • Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit • ResCheck inspector's checklist must be available at time of insulation inspection 2 Town of Queensbury Building&Codes Accessory Structure Application July 2014 DocuSign Envelope ID:C21DA09B-BAC542FO-86D5-3D8COF10EB24 K20 Walker Way m a n k a s s e l Colonie,NY 12205 (518)-078-8365 (518)-465-4161 Fax 06/01/15 This letter herebyauthorizes Kasselman Solar LLC,to act as Michael P.Angelucci (customer)agent &contractor. I further authorize Kasselman Solar LLC,to submit my building permit application to the necessary town building department. Customer Name(print) Michael P.Angelucci Doeuftned by: Customer Signature I Fl c ccl P. A 10F89MRSE043E... Customer Address 59 Noble Way Town Queensbury,NY 12804 D"uSlgned by: Kasselman Solar Employee Signature EH—A44-au EA2113A KOU11- Plump Engineering, Inc. 125 Wolf Road, Suite 505 Albany,NY 12205 518-729-4004 FAX: 518-729-3473 QAC NNitti@pei-ny.com nuu nou1tuu ixe. July 9, 2015 301.5-1-63 SOLAR-000680-2016 Angelucci, Michael Kasselman Solar 59 Noble Way 29 Broad Street Solar Panel System Albany,NY 12204 Reference: Angelucci Residence ---- - 59 Noble Way jQueensburry,NY, 12804 rE 326 Us 2a�6 iPEI# 5.150715.1 ,®JDearKassehnan Solar, & CODES Y The following is in reference to the structural roof analysis of the Angelucci Residence located in Queensbury,NY. PEI has been retained in order to analyze the adequacy of the existing roof structure to support the proposed additional loading due to rooftop solar panels. It has been determined that the main gable roof is adequate to support an additional 4psf loading due to the rooftop solar panels without limit to the quantity of panels or to their location on the main gable roof. If there are any further questions feel free to give us a call. Thank you. Plump Engineering Inc. Of NE{y TOWN OF OUEENSBURY ? oVAS A.pl r0 BUILDING DEPARMENT 'y zti� r� Based on our Gr,".^.d E-1.,-in'. a6on compliance with our commi;:-;;s s!r.:' :ot io construed Compliance indicating the pians an, specie construed are as in r Fxr: onns ,v full compliance with the Building Codes of �, m York State. '� yf`c0 091373 10 OPESS10Np� 07-09-15 Ryan Eagles TOWN OF QUEENSBUR Nicolas Nitti, RE Project Engineer BUILDING & CONS D Director of Engineering Reviewed By' Date: e B s 4 s CUSTOMER NAME: 4 SO WORLD 60 CELL 2 WATT MONO BLACK SOLAR PANELS Michael Angelucci _ENPHASE ZSOF7 ROINVERTERS---_ D CUSTOMER ADDRESS: D 59 Noble Way Queensbury,New York 128 IMMIMIMmgph;onp„nw„m,1..,w,aMpmy,.l,w,el,e.m. e1,Aac-u CUSTOMERPHONE: nm-12 NHTE-NEUIML 5182235881 oREEN-GROLNo Ir/21meTvmr:AL N N 200 IEMAINAttN2 Gp B4ARi BRBAREit RATRr pRD IN AuZDON C END OP a1B1E 240 AMP240 VOLT 11 M250a F£R_BMNCH GgarT e ESTING MAINN :T%M250au Mepn4Epra aandno GEC4m M.TM DCdw ELECTRICAL 4 NPW aM lrmubted M1am plats and meeb the mlwllemeMa ANCC Bpal1 A1250f PER_BRANCH CIgLnR DIS UUTDO\N PANEL _Mzsds PBx_BINNa1aRLun 9 9 a6 TIDRI GROUNDIP EXPOSED TO JUNCTION WXSPLICED TOS b BARE SOUDTHHN CONTINUING TO GROUNDSOLAR PANEISTO WEEK LUGS PER NEC&LOCAL REQNREMENTS 1 2P 20AIVSACQU 1127EHN GROUNDTO JUNCTION BOX SPACED TO RIMTERS PER NEC&LOCAL REQUIREMENTS aRCUII'BPE1R0l TYPIGLL ET1d:RNETLLNNECnGN ENWYCOaa&MG110N8OMEYMY Iti BROADBAND ROUIEIx B dtnwxpd.hab \ B Ne11a'4 12pWL PW.�DRB /C®IgVIKNpVaS _ _ Customer already has(21)SolazWodd 275W panels and(21)Enphase M250 inverters tied KASSELMAN SOLAR into(2)ISA breakers. We will add the new(4)Panels and inverters to one circuit and s s e I m a n N9 NY 12�5 upgrade it to a 20A breaker. SOLAR A JILLIAN LEPEVRE ��= ENPHASE M250 MICROINVERTER A JILLIANL®KASSELMANSOLARCOM FIELD WIRING DIAGRAM DIRECT:519-320-7669 240 VAC SINGLE PHASE PAX 518-953-1095 02013 Enpluae Ener Inp.All dents reserved a 1 S 4 1 1 2 Michael Angelucci 59 Noble Way Queensbury, New York (4) Solar World 290 & M250 Op �r Sunmodulei PI us SOLARWORLD SW 285-300 MONO (5-busbar) REALVALUE TUV Power controlled: nivanx°wa Lowest measuring tolerance in industry ° ® Every component is tested to meet 3 times IEC requirements J ® Designed to withstand heavy accumulations of snow and ice J ® Sunmodule Plus: Positive performance tolerance 25-year linear performance warranty and 10-year product warrant U) Glass with anti-refle it ting OCT 0 8 2016 - WJ TOVVN OF QUEENSBURY BUILDING& CODES World-class quality I;fl.,, Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites C us worldwide. ; 10n UL 1703 SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules / C that have greater than or equal to the nameplate rated power. ` G "°"'<<":..,`,°" 25-yearllnearperformance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course of25years,asignificant added value compared tnthetwo-phase warranties common ° "y in the industry,along with our industry-first 10-year product warranty." •Solar cells manufactured in U.S.A.or Germany.Modules assembled in U.S.A. **in accordance with the applicable SolarWorld Limited Warranty at purchase. vivay.solarworld.com/warranty 301.5-1-63 SOLAR-000680-2016 solarworld.com Angelucci, Michael MADEIN USA 59 Noble Way OPUS&IMPOMOPAaiS' Solar Panel System Sunmodule% Plus SW 285-300 MONO (5-busbar) REALVALUE PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' SW 285 SW 290 SW 295 5W 300 Maximum power Pm„ 285 Wp 290 Wp 295 Wp 300 Wp Open circuit voltage V. 39.7 V 39.9 V 40.0V 40.1 V Maximum PowerPoint voltage V.,. 31.3V 31AV 31.SV 31.6V Short circuit current I„ 9.84 A 9.97 A 10.10A 10.23 A Maximumpowerpofirtcurrent 1•,w 9.20A 9.33A 9.45A 9.57A Module efficlency 91. 17.00% 17.30% 17.59% 17.89% *STC:11000W/m'.25'C.AM 1.5 PERFORMANCE AT800 W/M1,NOCT,AM 1.5 SW 285 SW 290 SW 295 SW 300' Maximumpower p„„ -�- 213.1 Wp 217.1 Wp 220.5 Wp 224.1 Wp open circuit voltage V. 36.4 V 36,6V 36.7V 36.9 V Maximum PowerPoint voltage Vp 28.7 V 28.8 V 28.9 V 31.1 V Short circuit current 1k 7.96 A 8.06 A 8.17 A 8.27 A Maximum PowerPoint current I,npp 7.43 A 7.54 A 7.64A 7.75 A Minor reduction in efficiency under partial load conditions at 25'C:at 200 W/m'.700%of the STC efficiency 0000 W/mh is achieved. 'Preliminary values,subject to change. toa0 Winn,_Winn,__ _ _ COMPONENT MATERIALS I. Cells per module 60 Front Low-iron tempered glass 800 vv/ma with ARC(EN 12150) 600 whn' [ell type Monocrystalline 5-busbar Frame Clear anodized aluminum - E 6.17 in x 6.17 in aoo Wi - Cell dimensions (156.75 z 156.75 mm) weight 39.716s(18.0 kg) 200WAO THERMAL CHARACTERISTICS ADDITIONALDATA 100 W/m' NOR 46•C Powersorting -OWp/+SWp _.___... aeavkapaaM V. TO. 0.o4%/•C I.9ox IP6s TCV„ -030%/•C Connector PV wire per UL4703 37.8(961) TCP,,,- -0.41%/'C With H4/UTX connectors _ 4.20 a® Modulefireperformonce (UL 1703)Type 1 006.65) 1 T 4x Operating temp -40 to+85'C 7.12 00.26(6.6) (180.85) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION • 070.35(9) 0 Maximum system voltage SC fl/NEC 1000 V Maximum reverse current 25A a Numberof bypass diodes 3 0o j A � 1 e Design loads' Two sail system 113 psf dawnward,64 psf upward Design loads' Threirmilsystem 178 psf downward.64 psf upward Design loads' Edge mounting 178 psf downward,41 psf upward "Please refer to the Sunmodule installation Instructions for the details associated with these loadcases. e'spa •Compatible with both"Top-Down' • 005(9) 't" and"Bottom•mounting methods 1132 I •l Grounding Locations: (28750) uomt O -4 locations along the length of the I 39.4(IOm) module In the extended flange. �---- .I L 730(33) All units provided are imperial,Sl amts provided in parentheses -4 S013world AG reserves the right to make specification changes wthout notice. SW-01-751OUS 160324 Enphase,�Microinverters Enphase® M250 4 t , The E nphase i\1,,250 Nlicroinverier delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage' Cable, the Envoys Communications Gateway"", and Enlighten®, Enphasea monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE - Optimized for higher-power - No GEC needed for microinverter - 4th-generation product modules - No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and millions of units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable years [e] enphase, SA® E N E R G Y c us Enphase M250 Microinverter//DATA INPUT DATA(DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum Input DC voltage 48V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15A Max input current 10A OUTPUT DATA(AC) @208 VAC ®240 VAC Peak output power 250 W 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range' 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES _ Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground Is provided In the Engage Cable. No additional GEC or ground is required.Ground fault protection(GFP)is integrated Into the microinverter. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 `Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, fe 1 enphase, visit enphase.com E N E R G Y 0 2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owns. BOLT LOCATION 2 " BOLT LOCATION 3. 4 iii U N I RAC PRODUCT LINE: SOLARMOUNr DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL ANILTI GROUP COMPANY DRAWING TYPE: PART DETAIL a 1411 BROADWAY BLVD NE ALBUQUERQUE,NM 87102 USA DESCRIPTION: RAIL PRODUCT PROTECTED BY ONE WWW.UNIRAC.COM OR MORE US PATENTS. REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET %'BOLT LOCATION BOTTOM CLIP SLOT 3" %' BOLT LOCATION 17" 8 PRODUCT LINE: SOLARMOUNT iii U N I RAC DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL P/1 A HILTI GROUP COMPANY DRAWING TYPE: PART DETAIL00 d 1411 BROADWAY BLVD NE 1 ALBUQUERQUE,NM 87102 USA DESCRIPTION: HD RAIL PRODUCT PROTECTED BY ONE N WWW.UNIRAC.COM OR MORE US PATENTS REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET T 116 17 . T6 1 } " B CLAMP C CLAMP 30mm to 32mm Module Thickness D CLAMP (1.18'to 1.26') 33mm to 36mm Module Thickness (1.30"to 1.42' 38mm to 40mm Module Thickness (1.50"to 1.57") T 21- lib° 1a. K CLAMP F CLAMP 39mm to 41mm Module Thickness E CLAMP 45mm to 47mm Module Thickness (1.54'to 1.61') 50mm to 52mm Module Thickness (1.77"to 1.85) (1.97"to 2.05") 12 16" }"0 TYPICAL END CLAMP DETAILS UN I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE A HILTI GROUP COMPANY ALL DIMENSIONS ARE NOMINAL O DRAWING TYPE: PART a 1411 BROADWAY BLVD NE ALBUQUERQUE.NM 87102 USA DESCRIPTION: END CLAMPS PRODUCT PROTECTED BY ONE N WWW.UNIRAC.COM OR MORE US PATENTS REVISION DATE: FEBRUARY 2015 LEGAL NOTICE SHEET BONDING SPLICE BAR 0 0 0 0 1z. 16 4- #12 X j SELF DRILLING SS SCREWS INCLUDED TYPICAL SPLICE BAR DETAIL z NOTE T ONLY 2 SCREWS ARE TYPICAL EXPANSION JOINT DETAIL USED AT ANEXPANIONJOIT. USED AT AN EXPANSION JOINT. THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. MonU N I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE 0� ALL DIMENSIONS ARE NOMINAL �{ A Hari GROUPCOM ANY DRAWING TYPE: PART&ASSEMBLY 1411 BROADWAY BLVD NE caci ALBUQUERQUE.NM 87102 USA BONDING SPLICE BAR PRODUCT PROTECTED BY ONE OR MORE G DESCRIPTION: US PATENTS 4A VAMUNIRAC.COM REVISION DATE: SEPT 2014 LEGAL NOTICE $HEFT �16x}TBOLT }T 3 F-16 FLANGE NUT 3 0 L FOOT 2" I 2" SOLARMOUNT STANDARD ON L-FOOT " ua L MINIMUM HEIGHT MAXIMUM HEIGHT SOLARMOUNT HD ON L-FOOT T- 1'- s" 376 -k I MINIMUM HEIGHT MAXIMUM HEIGHT ���UNIRAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE an ALL DIMENSIONS ARE NOMINAL N A HILTI GROUP COMPWY DRAWING TYPE: PART&ASSEMBLY Q 1411 BROADWAY BLVD NE cc� ALBUQUERQUE,NM 87102 USA DESCRIPTION: L-FOOT PRODUCT PROTECTED BY ONE OR MORE L US PATENTS {I1 WWW.UNIRAC.COM REVISION DATE: $EPT 2014 j LEGAL NOTICE SHEET J-20 x 4 SS HEX HEAD BOLT — — T 'FLAT WASHER 1 � 0 }-20 SS FLANGE NUT BOTTOM CLIP A oleU N I RAC PRODUCT LINE: SOLARMOUNT HD DRAWING NOT TO SCALE �� ALL DIMENSIONS ARE NOMINAL 1'n A HILD GROUP COMPANY DRAWING TYPE: PART &ASSEMBLY 1411 BROADWAY BLVD NE Cai ALBUQUERQUE,NM 87102 USA DESCRIPTION: BOTTOM CLIP PRODUCT PROTECTED BY ONE OR MORE C VI WWW.UNIRAC.COM US PATENTS REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET B A 7DETAIL B - REAR TILT LEG DETAIL A - FRONT L FOOT HINGE �� PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE i0 U N I RAC ALL DIMENSIONS ARE NOMINAL C AHILTI GROUP COMPANY DRAWING TYPE: ASSEMBLY Q 1411 BROADWAY BLVD NE R ALBUQUERQUE.NM 87102 USA DESCRIPTION: LOW PROFILE TILT PRODUCT PROTECTED BY ONE N WWW.UNIRAC.COM OR MORE US PATENTS REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET A B ® 0 0 0 0 0 DETAIL A - REAR TILT LEG DETAIL B - L FOOT ii i AHIITI GROUPCOMU N I RAC' L1 PRODUCT LINE: SOLARMouNT DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL DRAWING TYPE: ASSEMBLY 1411 BROADWAY BLVD NE a ALBUQUERQUE,NM 87102 USA DESCRIPTION: HIGH PROFILE TILT PRODUCT PROTECTED BY ONE N WWW.UNIRAC.COM OR MORE US PATENTS REVISION DATE: iuNE 2014 LEGAL NOTICE SHEET S 1 . L FEET NOT INCLUDED 18 16 IN TILT LEG KITS 1' 8 STRUT LENGTHS -16 x 1-j'SS HEX BOLT ADJUSTABLE LENGTHS i x 1-}'x I' HD FENDER WASHER J-16 STRUT NUT O 1J-16 x 3"5S HEX BOLT A— 1-16 SS FLANGE NUT 1 08" SQUARETUBE LENGTHS TILT LEG LENGTHS TOTAL ADJUSTABLE SQUARETUBE STRUT LENGTHS 8"to 12" 8' 8" 1. 18'to 30' 18" 18" 16 116" 26'to 44" 26' 26" y 40'to 72" 40' 40' �� U N I RAC PRODUCT LINE: SOLARMOUNT TILT DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL AHILTI GROUP COMPANY DRAWING TYPE: ASSEMBLY O a 1411 BROADWAY BLVD NE ALBUQUERQUE,NM 87102 USA DESCRIPTION: ADJUSTABLE TILT LEG PRODUCT PROTECTED BY ONE N WWW.UNIRAC.COM OR MORE US PATENTS REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET BONDING SM MID CLAMP BONDING SM END CLAMP ol° 1?. 1'-. 1 6 i5- 16 16 VARIES- REFER TO SHEET SM-PO4 1. 4 I � 8 END CLAMP MID CLAMP UN I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL slm ANLLTI GROUPCOM DRAWING TYPE: PART&ASSEMBLY 1411 BROADWAY BLVD NE Q ALBUQUERQUE,NM 87102 USA DESCRIPTION: BONDING TOP CLAMPS PRODUCT PROTECTED BY ONE N WWW.UNIRAC.COM OR MORE US PATENTS REVISION DATE: SEPT 2014 LEGAL NOTICE SHEET NEON THE%►o.ST InspectnnsLC NORTHEAST ELECTRICAL INSPECTIONS, LLC 65 Albermarle Road Scotia, NY 12302 PHONE: (518) 852-0826 (518) 866-1663 ELECTRICAL INSPECTION CERTIFICATION This is to certify that the electrical wiring and equipment, which is introduced by the named applicant, is in the accordance with the National Electrical Code and local utility company. It also complies with the application on file at the date listed. Date of Final Inspection: 10/21/16 Job#: Angelucci Applicant: Kasselman Solar Address: 59 Noble Way Queensbury, NY Owner: Michael Angelucci Permit #: 000680-2016 Equipment Installed: (4) SolarWorld 60 Cell 290 Mono Black Solar Panels (4) Enphase M250 Microinverters Ca0v ASOWArarr Steve Reynolds Electrical Inspector