SOLAR-000680-2016 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
-• Community Development-Building&Codes (518)761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: SOLAR-000680-2016 Date Issued: Wednesday, August 23, 2017
This is to certify that work requested to be done as shown by Permit Number SOLAR-000680-2016
has been completed.
Tax Map Number: 301.5-1-63
Location: 59 NOBLE WAY
Owner: Michael Angelucci
Applicant: Michael Angelucci
This structure may be occupied as a: Solar Panel System
No Rafter Upgrades By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the 44t
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: SOLAR-000680-2016
Tax Map No: 301.5-1-63
Permission is hereby granted to: Michael Angelucci
For property located at: 59 NOBLE WAY
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvce of Construction
Owner Name: Michael Angelucci Solar Panel-Residential $400.00
Owner Address: 59 NOBLE WAY Total Value $400.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Kasselman Solar
20 Walker Way
Albany,NY 12205
Plans&Specifications
Solar Panel System
No Rafter Upgrades
$30.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,October 5,2017
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbug j?efore the ex4[�/tion
Qate.
Dated at the Town of ueensb , � r� /-AVed) ctober 5,2016
SIGNED BY: ( 1X V for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
ACCESSORY STRUCTURE APPLICATION
Received
DATE / J �O 7�I UJ Tax Map ID
�— ll�-Q 650 W1
TAX MAP ID 3� I � �'' ��� Permit No.
ZONING Permit Fee q �
HISTORIC SITE _Yes No Approvals
SUBDIVISION NAME Lot#
APPLICANT m pz ,, ��1��wt OWNER
1
ADDRESS 6 NCb V_ V (I1�� _ ADDRESS r`AOU (A 01 t�
PHONE - PHONEd3-
CONTRACTOR i a ,S eMAyn\�d�^`(,�/L� COST OF CONSTRUCTION(ESTIMATED): $
Z
ADDRESS: D \N(L,fJI-I� BUILDING ADDRESS:
/� _
PHONE: p 0(WSQ-I-� `J ioaSe-,
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE 1 PHONE
TYPE OF CONSTRUCTION
Check all that apply Please indicate measurements as required below
Boathouse 1"floor sq.ft. 2ntl floor sq.ft. Total sq.ft. Height
Boathouse with Sundeck
Deck -— -- --
Detached Garage(#of cars_) ----- -
Dock
Pole Earn ui
Porch-open TOUJNUS'6*. ' N8ISURY
+tl ,_ I::J �: J
Porch-3 season, Covered, Enclosed - .-_-- •-- —
Shed
Other Accessory Structure(s) / �Sf
'Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone
DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the
application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will
be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with
local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of
occupancy. I also understand that Uwe are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy. p
✓I have read and agree to the above: Print Name: A ��U ��l.t1 , Date: � 2
Signature: l Date:
1
Town of Queensbury Building&Codes Accessory Structure Application July 2014
ACCESSORY STRUCTURE APPLICATION (Requirements, Notes, Changes)
REQUIREMENTS:
1. Two (2)sets of the following documentation with the application and fee:
a) Plot plan drawn to scale with the use of a survey map, if possible (40 scale =40 feet)
b) Indicate proposed structure(s), showing setback dimensions from all surveyed property lines
c) Show location of all existing structure(s)on the property
d) Show location of water supply(well or water lines)
e) Show location and configuration of septic disposal system or sewer line.
2. Structural drawings to include: Floor plan; Foundation plan, Cross Sections, Elevations
3. Registered Architect or Engineer's stamp, signed &sealed for residential additionslalterations and any commercial
construction costs over$20,000
NoTEs:
1. A permit must be obtained before beginning construction
2. This permit is for any structure other than residential principal structure (house) to include, but not limited to: garage,
shed, dock, deck, carport, pole barn, greenhouse, etc. Refer to Informational Brochure No. 3—Accessory Structures —
ShedslFences.
3. Changes to Plan — Any changes prior to or during construction will require submittal of amended plans (review and re-
approval are necessary)
4. Withdrawn Permits: 20% of the initial fee is retainable by the Town. No fee is refundable after 1 year from initial
application date.
5. Additional review: All applications are subject to Zoning Administrator, Code Compliance and Structural Plan Review.
CHANGES To RESIDENTIAL BUILDING CODE EFFECTIVE 1-1-2011 (INFORMATIONAL):
Residential Building Code
• New driveway requirements for structures located over 300 feet from main road
• Spray foams are allowed to be exposed in rim joist box only, must be covered by 15 minute thermal barrier all other
areas;
• Protection against decay requirements
• Landings are no longer required on the outside of secondary doorways less than three risers provided no doors swing
over steps
• Vent stacks must be 18 inches minimum above roof for all structures
New Electrical Requirements
• Arc fault breakers required in all habitable spaces for receptacles
• GFI protection for all other receptacles in kitchens, bathrooms, garages and unfinished basements
• All receptacles must be tamper resistant
• Carbon Monoxide detectors must be located within 15 feet of sleeping areas;
• All corrugated stainless steel piping must be bonded to the common ground for electrical service
New Energy Code
• Blower door tests required by credential contractor or structure inspection by air barrier supplier and certified compliant
• Programmable thermostats required
• Lighting must be 50% energy saving light bulbs
• Separations between dwelling units must have minimum of R-10 in common wall of each dwelling unit
• ResCheck inspector's checklist must be available at time of insulation inspection
2
Town of Queensbury Building&Codes Accessory Structure Application July 2014
DocuSign Envelope ID:C21DA09B-BAC542FO-86D5-3D8COF10EB24
K20 Walker Way
m a n
k a s s e l Colonie,NY 12205
(518)-078-8365
(518)-465-4161 Fax
06/01/15
This letter herebyauthorizes Kasselman Solar LLC,to act as Michael P.Angelucci
(customer)agent
&contractor. I further authorize Kasselman Solar LLC,to submit my building permit application to the
necessary town building department.
Customer Name(print) Michael P.Angelucci
Doeuftned by:
Customer Signature I Fl c ccl P. A
10F89MRSE043E...
Customer Address 59 Noble Way
Town Queensbury,NY 12804
D"uSlgned by:
Kasselman Solar Employee Signature EH—A44-au
EA2113A KOU11-
Plump Engineering, Inc.
125 Wolf Road, Suite 505
Albany,NY 12205
518-729-4004 FAX: 518-729-3473
QAC NNitti@pei-ny.com
nuu nou1tuu ixe.
July 9, 2015 301.5-1-63 SOLAR-000680-2016
Angelucci, Michael
Kasselman Solar 59 Noble Way
29 Broad Street Solar Panel System
Albany,NY 12204
Reference: Angelucci Residence ---- -
59 Noble Way jQueensburry,NY, 12804 rE
326 Us 2a�6 iPEI# 5.150715.1 ,®JDearKassehnan Solar, & CODES Y
The following is in reference to the structural roof analysis of the Angelucci Residence
located in Queensbury,NY. PEI has been retained in order to analyze the adequacy of the
existing roof structure to support the proposed additional loading due to rooftop solar
panels.
It has been determined that the main gable roof is adequate to support an additional 4psf
loading due to the rooftop solar panels without limit to the quantity of panels or to their
location on the main gable roof.
If there are any further questions feel free to give us a call.
Thank you.
Plump Engineering Inc.
Of NE{y
TOWN OF OUEENSBURY ? oVAS A.pl r0
BUILDING DEPARMENT 'y zti� r�
Based on our Gr,".^.d E-1.,-in'. a6on compliance
with our commi;:-;;s s!r.:' :ot io construed Compliance
indicating the pians an, specie construed
are as in r Fxr: onns
,v full compliance with the Building Codes of �, m
York State. '�
yf`c0 091373
10 OPESS10Np� 07-09-15
Ryan Eagles TOWN OF QUEENSBUR Nicolas Nitti, RE
Project Engineer BUILDING & CONS D Director of Engineering
Reviewed By'
Date:
e B s 4 s
CUSTOMER NAME: 4 SO WORLD 60 CELL 2 WATT MONO BLACK SOLAR PANELS
Michael Angelucci
_ENPHASE ZSOF7 ROINVERTERS---_
D CUSTOMER ADDRESS:
D
59 Noble Way Queensbury,New York 128 IMMIMIMmgph;onp„nw„m,1..,w,aMpmy,.l,w,el,e.m.
e1,Aac-u
CUSTOMERPHONE: nm-12
NHTE-NEUIML
5182235881 oREEN-GROLNo
Ir/21meTvmr:AL N N
200
IEMAINAttN2 Gp
B4ARi BRBAREit RATRr pRD IN AuZDON
C
END OP a1B1E
240 AMP240 VOLT 11 M250a F£R_BMNCH GgarT e
ESTING MAINN :T%M250au Mepn4Epra aandno GEC4m M.TM DCdw
ELECTRICAL 4 NPW aM lrmubted M1am plats and meeb the mlwllemeMa ANCC Bpal1 A1250f PER_BRANCH CIgLnR
DIS UUTDO\N PANEL _Mzsds PBx_BINNa1aRLun
9 9 a6 TIDRI GROUNDIP EXPOSED TO JUNCTION WXSPLICED TOS b BARE SOUDTHHN CONTINUING TO GROUNDSOLAR
PANEISTO WEEK LUGS PER NEC&LOCAL REQNREMENTS
1 2P 20AIVSACQU 1127EHN GROUNDTO JUNCTION BOX SPACED TO RIMTERS PER NEC&LOCAL REQUIREMENTS
aRCUII'BPE1R0l
TYPIGLL ET1d:RNETLLNNECnGN
ENWYCOaa&MG110N8OMEYMY Iti BROADBAND ROUIEIx
B dtnwxpd.hab
\ B
Ne11a'4 12pWL PW.�DRB
/C®IgVIKNpVaS _
_ Customer already has(21)SolazWodd 275W panels and(21)Enphase M250 inverters tied
KASSELMAN SOLAR into(2)ISA breakers. We will add the new(4)Panels and inverters to one circuit and s s e I m a n
N9 NY 12�5 upgrade it to a 20A breaker. SOLAR
A JILLIAN LEPEVRE ��= ENPHASE M250 MICROINVERTER A
JILLIANL®KASSELMANSOLARCOM FIELD WIRING DIAGRAM
DIRECT:519-320-7669 240 VAC SINGLE PHASE
PAX 518-953-1095 02013 Enpluae Ener Inp.All dents reserved
a 1 S 4 1 1 2
Michael Angelucci
59 Noble Way Queensbury, New York
(4) Solar World 290 & M250
Op
�r
Sunmodulei PI us SOLARWORLD
SW 285-300 MONO (5-busbar) REALVALUE
TUV Power controlled:
nivanx°wa Lowest measuring tolerance in industry °
® Every component is tested to meet
3 times IEC requirements
J
® Designed to withstand heavy
accumulations of snow and ice
J
® Sunmodule Plus:
Positive performance tolerance
25-year linear performance warranty
and 10-year product warrant
U)
Glass with anti-refle it ting OCT 0 8 2016 -
WJ TOVVN OF QUEENSBURY
BUILDING& CODES
World-class quality I;fl.,,
Fully-automated production lines and seamless monitoring of the process and
material ensure the quality that the company sets as its benchmark for its sites C us
worldwide. ; 10n UL 1703
SolarWorld Plus-Sorting
Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules / C
that have greater than or equal to the nameplate rated power. ` G "°"'<<":..,`,°"
25-yearllnearperformance guarantee and extension of product warranty to 10 years
SolarWorld guarantees a maximum performance digression of 0.7%p.a.in the course
of25years,asignificant added value compared tnthetwo-phase warranties common ° "y
in the industry,along with our industry-first 10-year product warranty."
•Solar cells manufactured in U.S.A.or Germany.Modules assembled in U.S.A.
**in accordance with the applicable SolarWorld Limited Warranty at purchase.
vivay.solarworld.com/warranty
301.5-1-63 SOLAR-000680-2016
solarworld.com Angelucci, Michael MADEIN USA
59 Noble Way OPUS&IMPOMOPAaiS'
Solar Panel System
Sunmodule% Plus
SW 285-300 MONO (5-busbar) REALVALUE
PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)'
SW 285 SW 290 SW 295 5W 300
Maximum power Pm„ 285 Wp 290 Wp 295 Wp 300 Wp
Open circuit voltage V. 39.7 V 39.9 V 40.0V 40.1 V
Maximum PowerPoint voltage V.,. 31.3V 31AV 31.SV 31.6V
Short circuit current I„ 9.84 A 9.97 A 10.10A 10.23 A
Maximumpowerpofirtcurrent 1•,w 9.20A 9.33A 9.45A 9.57A
Module efficlency 91. 17.00% 17.30% 17.59% 17.89%
*STC:11000W/m'.25'C.AM 1.5
PERFORMANCE AT800 W/M1,NOCT,AM 1.5
SW 285 SW 290 SW 295 SW 300'
Maximumpower p„„ -�- 213.1 Wp 217.1 Wp 220.5 Wp 224.1 Wp
open circuit voltage V. 36.4 V 36,6V 36.7V 36.9 V
Maximum PowerPoint voltage Vp 28.7 V 28.8 V 28.9 V 31.1 V
Short circuit current 1k 7.96 A 8.06 A 8.17 A 8.27 A
Maximum PowerPoint current I,npp 7.43 A 7.54 A 7.64A 7.75 A
Minor reduction in efficiency under partial load conditions at 25'C:at 200 W/m'.700%of the STC efficiency 0000 W/mh is achieved.
'Preliminary values,subject to change.
toa0 Winn,_Winn,__ _ _ COMPONENT MATERIALS
I.
Cells per module 60 Front Low-iron tempered glass
800 vv/ma with ARC(EN 12150)
600 whn'
[ell type Monocrystalline
5-busbar Frame Clear anodized aluminum
-
E 6.17 in x 6.17 in
aoo Wi - Cell dimensions (156.75 z 156.75 mm) weight 39.716s(18.0 kg)
200WAO THERMAL CHARACTERISTICS ADDITIONALDATA
100 W/m'
NOR 46•C Powersorting -OWp/+SWp
_.___... aeavkapaaM
V. TO. 0.o4%/•C I.9ox IP6s
TCV„ -030%/•C Connector PV wire per UL4703
37.8(961) TCP,,,- -0.41%/'C With H4/UTX connectors
_
4.20 a® Modulefireperformonce (UL 1703)Type 1
006.65) 1 T 4x Operating temp -40 to+85'C
7.12 00.26(6.6)
(180.85) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION
• 070.35(9)
0
Maximum system voltage SC fl/NEC 1000 V
Maximum reverse current 25A
a Numberof bypass diodes 3
0o j A
� 1 e
Design loads' Two sail system 113 psf dawnward,64 psf upward
Design loads' Threirmilsystem 178 psf downward.64 psf upward
Design loads' Edge mounting 178 psf downward,41 psf upward
"Please refer to the Sunmodule installation Instructions for the details associated with these loadcases.
e'spa •Compatible with both"Top-Down'
• 005(9) 't" and"Bottom•mounting methods
1132 I •l Grounding Locations:
(28750) uomt O -4 locations along the length of the
I
39.4(IOm) module In the extended flange.
�---- .I L
730(33)
All units provided are imperial,Sl amts provided in parentheses -4
S013world AG reserves the right to make specification changes wthout notice. SW-01-751OUS 160324
Enphase,�Microinverters
Enphase® M250
4
t ,
The E nphase i\1,,250 Nlicroinverier delivers increased energy harvest and reduces design and
installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated
from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This
further simplifies installation, enhances safety, and saves on labor and materials costs.
The Enphase M250 integrates seamlessly with the Engage' Cable, the Envoys Communications
Gateway"", and Enlighten®, Enphasea monitoring and analysis software.
PRODUCTIVE SIMPLE RELIABLE
- Optimized for higher-power - No GEC needed for microinverter - 4th-generation product
modules - No DC design or string calculation - More than 1 million hours of testing
- Maximizes energy production required and millions of units shipped
- Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25
dust, and debris Cable years
[e] enphase, SA®
E N E R G Y
c us
Enphase M250 Microinverter//DATA
INPUT DATA(DC) M250-60-2LL-S22/S23/S24
Recommended input power(STC) 210-300 W
Maximum Input DC voltage 48V
Peak power tracking voltage 27 V-39 V
Operating range 16 V-48 V
Min/Max start voltage 22 V/48 V
Max DC short circuit current 15A
Max input current 10A
OUTPUT DATA(AC) @208 VAC ®240 VAC
Peak output power 250 W 250 W
Rated(continuous)output power 240 W 240 W
Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration)
Nominal voltage/range 208 V/183-229 V 240 V/211-264 V
Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz
Extended frequency range' 57-62.5 Hz 57-62.5 Hz
Power factor >0.95 >0.95
Maximum units per 20 A branch circuit 24(three phase) 16(single phase)
Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles
EFFICIENCY
CEC weighted efficiency,240 VAC 96.5%
CEC weighted efficiency,208 VAC 96.0%
Peak inverter efficiency 96.5%
Static MPPT efficiency(weighted,reference EN50530) 99.4%
Night time power consumption 65 mW max
MECHANICAL DATA
Ambient temperature range -40°C to+65°C
Operating temperature range(internal) -40°C to+85°C
Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket)
Weight 2.0 kg
Cooling Natural convection-No fans
Enclosure environmental rating Outdoor-NEMA 6
FEATURES _
Compatibility Compatible with 60-cell PV modules.
Communication Power line
Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in
NEC 690.35.Equipment ground Is provided In the Engage Cable. No
additional GEC or ground is required.Ground fault protection(GFP)is
integrated Into the microinverter.
Monitoring Free lifetime monitoring via Enlighten software
Compliance UL1741/IEEE1547, FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91,
0.4-04,and 107.1-01
`Frequency ranges can be extended beyond nominal if required by the utility
To learn more about Enphase Microinverter technology, fe 1 enphase,
visit enphase.com E N E R G Y
0 2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owns.
BOLT LOCATION
2
" BOLT LOCATION
3.
4
iii U N I RAC PRODUCT LINE: SOLARMOUNr DRAWING NOT TO SCALE
ALL DIMENSIONS ARE NOMINAL
ANILTI GROUP COMPANY DRAWING TYPE: PART DETAIL
a
1411 BROADWAY BLVD NE
ALBUQUERQUE,NM 87102 USA DESCRIPTION: RAIL PRODUCT PROTECTED BY ONE
WWW.UNIRAC.COM OR MORE US PATENTS.
REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET
%'BOLT LOCATION
BOTTOM CLIP SLOT
3"
%' BOLT LOCATION
17"
8
PRODUCT LINE: SOLARMOUNT
iii U N I RAC DRAWING NOT TO SCALE
ALL DIMENSIONS ARE NOMINAL P/1
A HILTI GROUP COMPANY DRAWING TYPE: PART DETAIL00
d
1411 BROADWAY BLVD NE 1
ALBUQUERQUE,NM 87102 USA DESCRIPTION: HD RAIL PRODUCT PROTECTED BY ONE N
WWW.UNIRAC.COM OR MORE US PATENTS
REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET
T
116 17 .
T6 1 } "
B CLAMP C CLAMP
30mm to 32mm Module Thickness D CLAMP
(1.18'to 1.26') 33mm to 36mm Module Thickness
(1.30"to 1.42' 38mm to 40mm Module Thickness
(1.50"to 1.57")
T
21- lib° 1a.
K CLAMP
F CLAMP 39mm to 41mm Module Thickness
E CLAMP 45mm to 47mm Module Thickness (1.54'to 1.61')
50mm to 52mm Module Thickness (1.77"to 1.85)
(1.97"to 2.05")
12
16" }"0
TYPICAL END CLAMP DETAILS
UN I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE
A HILTI GROUP COMPANY ALL DIMENSIONS ARE NOMINAL O
DRAWING TYPE: PART a
1411 BROADWAY BLVD NE
ALBUQUERQUE.NM 87102 USA DESCRIPTION: END CLAMPS PRODUCT PROTECTED BY ONE N
WWW.UNIRAC.COM OR MORE US PATENTS
REVISION DATE: FEBRUARY 2015 LEGAL NOTICE SHEET
BONDING SPLICE BAR
0 0 0 0
1z.
16 4-
#12 X j SELF DRILLING SS SCREWS INCLUDED
TYPICAL SPLICE BAR DETAIL
z
NOTE
T ONLY 2 SCREWS ARE
TYPICAL EXPANSION JOINT DETAIL USED AT ANEXPANIONJOIT.
USED AT AN EXPANSION JOINT.
THE SPLICE BAR DOES NOT BOND
ACROSS AN EXPANSION JOINT.
MonU N I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE
0� ALL DIMENSIONS ARE NOMINAL �{
A Hari GROUPCOM ANY DRAWING TYPE: PART&ASSEMBLY
1411 BROADWAY BLVD NE caci
ALBUQUERQUE.NM 87102 USA BONDING SPLICE BAR PRODUCT PROTECTED BY ONE OR MORE G
DESCRIPTION: US PATENTS 4A
VAMUNIRAC.COM
REVISION DATE: SEPT 2014
LEGAL NOTICE $HEFT
�16x}TBOLT
}T 3
F-16
FLANGE NUT
3 0 L FOOT
2" I 2"
SOLARMOUNT STANDARD ON L-FOOT
"
ua L
MINIMUM HEIGHT MAXIMUM HEIGHT
SOLARMOUNT HD ON L-FOOT
T-
1'-
s"
376
-k I
MINIMUM HEIGHT MAXIMUM HEIGHT
���UNIRAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE
an ALL DIMENSIONS ARE NOMINAL N
A HILTI GROUP COMPWY DRAWING TYPE:
PART&ASSEMBLY Q
1411 BROADWAY BLVD NE cc�
ALBUQUERQUE,NM 87102 USA DESCRIPTION: L-FOOT PRODUCT PROTECTED BY ONE OR MORE L
US PATENTS {I1
WWW.UNIRAC.COM
REVISION DATE: $EPT 2014 j LEGAL NOTICE SHEET
J-20 x 4 SS HEX HEAD BOLT
— — T 'FLAT WASHER
1 �
0
}-20 SS FLANGE NUT
BOTTOM CLIP
A
oleU N I RAC PRODUCT LINE: SOLARMOUNT HD DRAWING NOT TO SCALE
�� ALL DIMENSIONS ARE NOMINAL 1'n
A HILD GROUP COMPANY DRAWING TYPE: PART &ASSEMBLY
1411 BROADWAY BLVD NE Cai
ALBUQUERQUE,NM 87102 USA DESCRIPTION: BOTTOM CLIP PRODUCT PROTECTED BY ONE OR MORE C
VI
WWW.UNIRAC.COM US PATENTS
REVISION DATE: JUNE 2014
LEGAL NOTICE SHEET
B
A
7DETAIL B - REAR TILT LEG
DETAIL A - FRONT L FOOT HINGE
�� PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE
i0 U N I RAC ALL DIMENSIONS ARE NOMINAL C
AHILTI GROUP COMPANY DRAWING TYPE: ASSEMBLY
Q
1411 BROADWAY BLVD NE R
ALBUQUERQUE.NM 87102 USA DESCRIPTION: LOW PROFILE TILT PRODUCT PROTECTED BY ONE N
WWW.UNIRAC.COM OR MORE US PATENTS
REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET
A
B
® 0 0
0
0 0
DETAIL A - REAR TILT LEG DETAIL B - L FOOT
ii
i
AHIITI GROUPCOMU N I RAC' L1
PRODUCT LINE: SOLARMouNT DRAWING NOT TO SCALE
ALL DIMENSIONS ARE NOMINAL
DRAWING TYPE: ASSEMBLY
1411 BROADWAY BLVD NE a
ALBUQUERQUE,NM 87102 USA DESCRIPTION: HIGH PROFILE TILT PRODUCT PROTECTED BY ONE N
WWW.UNIRAC.COM OR MORE US PATENTS
REVISION DATE: iuNE 2014 LEGAL NOTICE SHEET
S 1 . L FEET NOT INCLUDED
18 16 IN TILT LEG KITS
1'
8
STRUT
LENGTHS
-16 x 1-j'SS HEX BOLT
ADJUSTABLE LENGTHS i x 1-}'x I' HD FENDER WASHER
J-16 STRUT NUT
O
1J-16 x 3"5S HEX BOLT
A— 1-16 SS FLANGE NUT
1
08"
SQUARETUBE
LENGTHS
TILT LEG LENGTHS
TOTAL
ADJUSTABLE SQUARETUBE STRUT
LENGTHS
8"to 12" 8' 8"
1. 18'to 30' 18" 18"
16
116" 26'to 44" 26' 26"
y
40'to 72" 40' 40'
�� U N I RAC PRODUCT LINE: SOLARMOUNT TILT DRAWING NOT TO SCALE
ALL DIMENSIONS ARE NOMINAL
AHILTI GROUP COMPANY DRAWING TYPE: ASSEMBLY O
a
1411 BROADWAY BLVD NE
ALBUQUERQUE,NM 87102 USA DESCRIPTION: ADJUSTABLE TILT LEG PRODUCT PROTECTED BY ONE N
WWW.UNIRAC.COM OR MORE US PATENTS
REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET
BONDING SM MID CLAMP BONDING SM END CLAMP
ol°
1?.
1'-.
1 6
i5-
16 16
VARIES- REFER TO
SHEET SM-PO4
1.
4
I � 8
END CLAMP
MID CLAMP
UN I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE
ALL DIMENSIONS ARE NOMINAL
slm
ANLLTI GROUPCOM
DRAWING TYPE: PART&ASSEMBLY
1411 BROADWAY BLVD NE Q
ALBUQUERQUE,NM 87102 USA DESCRIPTION: BONDING TOP CLAMPS PRODUCT PROTECTED BY ONE N
WWW.UNIRAC.COM OR MORE US PATENTS
REVISION DATE: SEPT 2014 LEGAL NOTICE SHEET
NEON THE%►o.ST
InspectnnsLC
NORTHEAST ELECTRICAL INSPECTIONS, LLC
65 Albermarle Road
Scotia, NY 12302
PHONE: (518) 852-0826
(518) 866-1663
ELECTRICAL INSPECTION CERTIFICATION
This is to certify that the electrical wiring and equipment, which is introduced by the named
applicant, is in the accordance with the National Electrical Code and local utility company. It
also complies with the application on file at the date listed.
Date of Final Inspection: 10/21/16 Job#: Angelucci
Applicant: Kasselman Solar
Address: 59 Noble Way
Queensbury, NY
Owner: Michael Angelucci
Permit #: 000680-2016
Equipment Installed: (4) SolarWorld 60 Cell 290 Mono Black Solar Panels
(4) Enphase M250 Microinverters
Ca0v ASOWArarr
Steve Reynolds
Electrical Inspector