Loading...
RC-000688-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000688-2016 Date Issued: Tuesday, May 30, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000688-2016 has been completed. Tax Map Number: 301.7-1-48 Location: 22 BUENA VISTA AVE Owner: Debbie Allamena Applicant: Capital District Contractors& Decks This structure may be occupied as a: Residential Alteration 180 s.f Residential Addition 228 s.f. By Order of Town Board TOWN OF QUEENSSJ�BURY Issuance of this Certificate of Occupancy DOES NOT relieve the Q41 Issuance property owner of the responsibility for compliance with Site Plan, ( Variance,or other issues and conditions as a result of approvals by the Director of Building&.Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000688-2016 Tax Map No: 301.7-1-48 Permission is hereby granted to: Capital District Contractors&Decks For property located at: 22 BUENA VISTA AVE In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Debbie Allamena Single Family-Addition $60,000.00 Owner Address: 22 BUENA VISTA AVE Total Value $60,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Capital District Contractors&Decks PO Box 1092 Clifton Park,NY 12065 Plans&Specifications Residential Alteration 180 s.f Residential Addition 228 s.f. $160.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,October 20,2017 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the exxp�iration date.) Dated at the Town o ueen ry�;S.�/ J /J Thur y, 20,2016 SIGNED BY: �'^'�(�// /vJ for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: ✓�,- Permit No. K- - � - ZG?\b Tax Map ID Permit Fee -'s ) (00 Zone Historic? _Yes No Rec Fee 1>,V"iw tial Subdivision Name Lot# Site Plan# Subdivision# Project Location 2Z 50r-_ J& �(�STI_S. AgkL- TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit feels). Primary Owner(s) 6r ,— Address -2_-L l; Phone/Email 5 eb Applicant CAPITAL DISTRICT CONTRACTORS &DECKS Address P.O. BOX 1092 CLIFTON PARK, NEW YORK 12055 Phone/Email 3 l _ cd O 1--) k � N -) � g0l� Contractor CAPITAL DISTRICT CONTRACTORS P. nrrK.R Address P.O. BOX 1092 Phone/Email ? Cl lFTQN PARK, NEWYORK 12666 � _ o kk p Contact Person for Building& Codes Compliance: Phone '577 1 UL TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration V floor sf 211 floor sf Total sf Height Single Family ✓ l97J Two-Family Multi-Family (#of units Townhouse Business Office Retail -Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition C-5k 4L, Source of Heat(circle one) Gas Oil Propane Solar izthey Fireplace: Complete a separate application for Fuel Bunting Appliances & Chimneys Are there structures not shown on plot plan? A.50 Are there easements on the property? O Site Information: a. Dimensions or acreage of lot l 6 0 x t o co l 5 a 1 b. Is this a comer lot? _Yes ✓ No c. Will the grade be changed as a result of construction _Yes ✓ No d. Public water or Private well (circle one) Public Private e. Sewer or Private Septic System(circle one) Sewer Private Value of all work to be performed(labor or materials) $ DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed,I or my agents will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: DATE: SIGNATURE: DATE: `J 0 9 For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 LIGHT VENTILLATION & EGRESS WORK SHEET PROJECT NAME: Allamena Residence,22 Buena Vista Avenue,Queensbury, New York 12804 SQ FT EGRESS EGRESS LIGHT LIGHT VENT VENT CLEAR OPEN OPEN ROOM SQ FEET MODEL REOD 8% ACTUAL REQD 4% ACTUAL OPEN WIDTH HEIGHT 4 Season Room 408 (3)4056 DH 32.64 48.6 16.32 26.4 8.8 457/8 30114 (1) 3068 DR (6) 106 SKY (3) 3456 SL (5) 3856 SL (3) 4010 FX (3) 3410 FX (5) 3810 FX 124 (4)4056 SL 9.92 4.96 Enclosed Porch (2) 3068 DR 18.4 28.8 14.4 Simonton Windows u - 301.7-1-48 RC-000688-2016 Allamena, Debbie 22 Buena Vista Avenue Res. Alt. 180 s.f., Res. Add. 228 s.f. LIGHT VENTILLATION & EGRESS WORK SHEET PROJECT NAME: Allamena Residence, 22 Buena Vista Avenue, Queensbury, New York 12804 SQ FT EGRESS EGRESS LIGHT LIGHT VENT VENT CLEAR OPEN OPEN ROOM SQ FEET MODEL RE D 8% ACTUAL READ 4% ACTUAL OPEN WIDTH HEIGHT 4 Season Room 408 (3)4056 DH 32.64 48.6 16.32 26.4 8.8 457/8 301/4 (1) 3068 DR (6) 106 SKY (3) 3456 SL (5) 3856 SL (3)4010 FX (3) 3410 FX (5) 3810 FX 124 (4)4056 SL 9.92 4.96 Enclosed Porch (2) 3068 DR 18.4 28.8 14.4 Simonton Windows 301.74-48 RC-000688-2016 Allamena, Debbie 22 Buena Vista Avenue Res. Alt. 180 s.f., Res. Add. 228 S.f. REScheck Software Version 4.6.2 Compliance Certificate r 00 N N 00 N S*.OF NEW t�0 C7 Project Allamena Residence a� o � � Energy Code: 2010 New York Energy Conservation Location: Saratoga County, New York r n 07 > Construction Type: Single-family 16 Project Type: Addition 2S d cn Climate Zone: 5 (7244 HDD) �� d 6 > OD Permit Date: Permit Number: r„ Construction Site: Owner/Agent: Designer/Contractor: n E m 22 Buena Vista Avenue Debbie Allamena Allen Packard 0 Queensbury, NY 12804 22 Buena Vista Avenue AI Packard Drafting Services M Q N Queensbury, NY 12804 57 Vettura Court 518-338-5859 Malta,NY 12020 debbiejamusic@gmail.com 518-577-9522 apackardjr@nycap,rr.com Compliance: Passes using UA trade-off Compliance: 16.9%Better Than Code Maximum UA: 118 Your UA: 98 The%Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss UCT 06 201 r,408 30.0 0.0 0.035 13 Skylight 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 42 0.290 12 Wall 1:Wood Frame, 16"D.C. 472 21.0 0.3 0.056 18 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E -- 124 0.290 36 Door 1: Glass 20 0.290 6 Floor 1:All-Wood joist/rruss:Over Unconditioned Space 408 30.0 0.0 0.033 13 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy Conservation Construction Code requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Sign ure Date Project Title: Allamena Residence Report date: 10/03/16 Data filename: C:\Users\owner\Desktop\Business Files\2016 RESIDENTIAL JOB FILES\SUNROOMS, Pagel of 1 SCREEN ROOMS\ALLAM ENA 4 SEASON ROOM\REScheck for Allamena REsidence.rck Feb. 10. 2017 12: 28P MDIA No. 6867 P. 2/2 MIDDLE DEPARTMENT INSPECTION AGENCY, INC. T&+6riQ that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Debbie Allamena Date: 02/03/2017 Occupant: 1St FI Rear/Addition Location 2 Beuna Vista Ave Occupancy .mgle Family Owg. Queensbury, Warren Co. NY Applicant: Capital District Decks& Contracting/Dave Bemacki PO Box 1092 L Clifton Park, NY 1206.5 JosephA,Holmes t • 20 Jo No. ,032268205556EL Equipment: 1 -Mini Split; 2-Arc Fault Breakers;4-Switches: 8-'Receptacles;21 -Fixtures; 1 - Dryer, 1 -20 Amp.Washer Receptacle EC COW FEB 10 2017 TOWN OF OUIF NSBURY BUILDING R LODES This certificate applies to the electrical wiring to the electrical equipment listed Immediately null and void. This caNficare applies only to the use.occupancy end above and the installation inspected as of the above noted data barred on a Nsual ownership as indicated herein. Upon a change in the use,occupancy or Ownership inspection. No warranty is expressed or implied as to the mechanical safety,of . of the property indicated above,this ceelcam shall be immediately nun and void, etency or fitness of the equipment for any particular purpose. This cenineate shall In the event that this ceniacate becomes invalid based upon the above conditions• be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalicated upon relnepeetfon by Middle Department system to which Chia certlfleate applies be altered in anyway.including but nal limit- Inspection Agenry,Inc. An epplicatlon fpr inapettien moat be suomlded to Middle ed to.Me indoduction of additional elettncal equipment antl/or the replacement of Depertmenl Inspection Agency, Inc, to initiate the ingpecYon and revalidation any of the components Installed as of the above notetl date,this Cenirldale shall be process. A fes will be charged for this cervica. '