RC-000688-2016 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000688-2016 Date Issued: Tuesday, May 30, 2017
This is to certify that work requested to be done as shown by Permit Number RC-000688-2016
has been completed.
Tax Map Number: 301.7-1-48
Location: 22 BUENA VISTA AVE
Owner: Debbie Allamena
Applicant: Capital District Contractors& Decks
This structure may be occupied as a: Residential Alteration 180 s.f
Residential Addition 228 s.f. By Order of Town Board
TOWN OF QUEENSSJ�BURY
Issuance of this Certificate of Occupancy DOES NOT relieve the Q41
Issuance
property owner of the responsibility for compliance with Site Plan, (
Variance,or other issues and conditions as a result of approvals by the
Director of Building&.Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000688-2016
Tax Map No: 301.7-1-48
Permission is hereby granted to: Capital District Contractors&Decks
For property located at: 22 BUENA VISTA AVE
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tyne of Construction
Owner Name: Debbie Allamena Single Family-Addition $60,000.00
Owner Address: 22 BUENA VISTA AVE Total Value $60,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Capital District Contractors&Decks
PO Box 1092
Clifton Park,NY 12065
Plans&Specifications
Residential Alteration 180 s.f
Residential Addition 228 s.f.
$160.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,October 20,2017
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the exxp�iration date.)
Dated at the Town o ueen ry�;S.�/ J /J Thur y, 20,2016
SIGNED BY: �'^'�(�// /vJ for the Town of Queensbury.
Director of Building&Code Enforcement
PRINCIPAL STRUCTURE APPLICATION Office Use Only
Date: ✓�,-
Permit No. K- - � - ZG?\b
Tax Map ID Permit Fee -'s ) (00
Zone Historic? _Yes No Rec Fee 1>,V"iw tial
Subdivision Name Lot# Site Plan#
Subdivision#
Project Location 2Z 50r-_ J& �(�STI_S. AgkL-
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit feels).
Primary Owner(s)
6r ,—
Address -2_-L l;
Phone/Email 5
eb
Applicant CAPITAL DISTRICT CONTRACTORS
&DECKS
Address P.O. BOX 1092
CLIFTON PARK, NEW YORK 12055
Phone/Email 3 l _ cd O 1--) k � N -) � g0l�
Contractor CAPITAL DISTRICT CONTRACTORS
P. nrrK.R
Address P.O. BOX 1092
Phone/Email ? Cl lFTQN PARK, NEWYORK 12666
� _ o kk p
Contact Person for Building& Codes Compliance: Phone '577 1 UL
TYPE OF CONSTRUCTION
✓Check all that apply New Addition Alteration V floor sf 211 floor sf Total sf Height
Single Family ✓ l97J
Two-Family
Multi-Family
(#of units
Townhouse
Business Office
Retail -Mercantile
Factory-Industrial
Attached Garage
(1, 2, 3, 4+)
Other
Town of Queensbury Building&Codes Principal Structure Application revised January 2016
If commercial or industrial please indicate name of business
Proposed use of building or addition C-5k 4L,
Source of Heat(circle one) Gas Oil Propane Solar izthey
Fireplace: Complete a separate application for Fuel Bunting
Appliances & Chimneys
Are there structures not shown on plot plan? A.50
Are there easements on the property? O
Site Information:
a. Dimensions or acreage of lot l 6 0 x t o co l 5 a 1
b. Is this a comer lot? _Yes ✓ No
c. Will the grade be changed as a result of construction _Yes ✓ No
d. Public water or Private well (circle one) Public Private
e. Sewer or Private Septic System(circle one) Sewer Private
Value of all work to be performed(labor or materials) $
DECLARATION.
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes, local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed,I or my agents will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: DATE:
SIGNATURE: DATE: `J 0
9
For office use only
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
LIGHT VENTILLATION & EGRESS WORK SHEET
PROJECT NAME: Allamena Residence,22 Buena Vista Avenue,Queensbury, New York 12804
SQ FT EGRESS EGRESS
LIGHT LIGHT VENT VENT CLEAR OPEN OPEN
ROOM SQ FEET MODEL REOD 8% ACTUAL REQD 4% ACTUAL OPEN WIDTH HEIGHT
4 Season Room 408 (3)4056 DH 32.64 48.6 16.32 26.4 8.8 457/8 30114
(1) 3068 DR
(6) 106 SKY
(3) 3456 SL
(5) 3856 SL
(3) 4010 FX
(3) 3410 FX
(5) 3810 FX
124 (4)4056 SL 9.92 4.96
Enclosed Porch (2) 3068 DR 18.4 28.8 14.4
Simonton Windows
u -
301.7-1-48 RC-000688-2016
Allamena, Debbie
22 Buena Vista Avenue
Res. Alt. 180 s.f., Res. Add. 228 s.f.
LIGHT VENTILLATION & EGRESS WORK SHEET
PROJECT NAME: Allamena Residence, 22 Buena Vista Avenue, Queensbury, New York 12804
SQ FT EGRESS EGRESS
LIGHT LIGHT VENT VENT CLEAR OPEN OPEN
ROOM SQ FEET MODEL RE D 8% ACTUAL READ 4% ACTUAL OPEN WIDTH HEIGHT
4 Season Room 408 (3)4056 DH 32.64 48.6 16.32 26.4 8.8 457/8 301/4
(1) 3068 DR
(6) 106 SKY
(3) 3456 SL
(5) 3856 SL
(3)4010 FX
(3) 3410 FX
(5) 3810 FX
124 (4)4056 SL 9.92 4.96
Enclosed Porch (2) 3068 DR 18.4 28.8 14.4
Simonton Windows
301.74-48 RC-000688-2016
Allamena, Debbie
22 Buena Vista Avenue
Res. Alt. 180 s.f., Res. Add. 228 S.f.
REScheck Software Version 4.6.2
Compliance Certificate r
00
N N
00 N
S*.OF NEW t�0 C7
Project Allamena Residence
a�
o � �
Energy Code: 2010 New York Energy Conservation
Location: Saratoga County, New York r n 07 >
Construction Type: Single-family 16
Project Type: Addition 2S d cn
Climate Zone: 5 (7244 HDD) �� d 6 > OD
Permit Date:
Permit Number: r„
Construction Site: Owner/Agent: Designer/Contractor: n E m
22 Buena Vista Avenue Debbie Allamena Allen Packard 0
Queensbury, NY 12804 22 Buena Vista Avenue AI Packard Drafting Services M Q N
Queensbury, NY 12804 57 Vettura Court
518-338-5859 Malta,NY 12020
debbiejamusic@gmail.com 518-577-9522
apackardjr@nycap,rr.com
Compliance: Passes using UA trade-off
Compliance: 16.9%Better Than Code Maximum UA: 118 Your UA: 98
The%Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss UCT 06 201
r,408 30.0 0.0 0.035 13
Skylight 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 42 0.290 12
Wall 1:Wood Frame, 16"D.C. 472 21.0 0.3 0.056 18
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E -- 124 0.290 36
Door 1: Glass 20 0.290 6
Floor 1:All-Wood joist/rruss:Over Unconditioned Space 408 30.0 0.0 0.033 13
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2010 New York Energy
Conservation Construction Code requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in
the REScheck Inspection Checklist.
Name-Title Sign ure Date
Project Title: Allamena Residence Report date: 10/03/16
Data filename: C:\Users\owner\Desktop\Business Files\2016 RESIDENTIAL JOB FILES\SUNROOMS, Pagel of 1
SCREEN ROOMS\ALLAM ENA 4 SEASON ROOM\REScheck for Allamena REsidence.rck
Feb. 10. 2017 12: 28P MDIA No. 6867 P. 2/2
MIDDLE DEPARTMENT INSPECTION AGENCY, INC.
T&+6riQ that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner: Debbie Allamena Date: 02/03/2017
Occupant: 1St FI Rear/Addition Location 2 Beuna Vista Ave
Occupancy .mgle Family Owg. Queensbury, Warren Co. NY
Applicant:
Capital District Decks&
Contracting/Dave Bemacki
PO Box 1092
L Clifton Park, NY 1206.5
JosephA,Holmes t • 20 Jo
No. ,032268205556EL
Equipment:
1 -Mini Split; 2-Arc Fault Breakers;4-Switches: 8-'Receptacles;21 -Fixtures; 1 - Dryer, 1 -20 Amp.Washer
Receptacle
EC COW
FEB 10 2017
TOWN OF OUIF NSBURY
BUILDING R LODES
This certificate applies to the electrical wiring to the electrical equipment listed Immediately null and void. This caNficare applies only to the use.occupancy end
above and the installation inspected as of the above noted data barred on a Nsual ownership as indicated herein. Upon a change in the use,occupancy or Ownership
inspection. No warranty is expressed or implied as to the mechanical safety,of . of the property indicated above,this ceelcam shall be immediately nun and void,
etency or fitness of the equipment for any particular purpose. This cenineate shall In the event that this ceniacate becomes invalid based upon the above conditions•
be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalicated upon relnepeetfon by Middle Department
system to which Chia certlfleate applies be altered in anyway.including but nal limit- Inspection Agenry,Inc. An epplicatlon fpr inapettien moat be suomlded to Middle
ed to.Me indoduction of additional elettncal equipment antl/or the replacement of Depertmenl Inspection Agency, Inc, to initiate the ingpecYon and revalidation
any of the components Installed as of the above notetl date,this Cenirldale shall be process. A fes will be charged for this cervica. '