Loading...
SOLAR-000827-2016 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-000827-2016 Date Issued: Thursday, November 1, 2018 This is to certify that work requested to be done as shown by Permit Number SOLAR-000827-2016 has been completed. Tax Map Number: 296.13-1-24.2 Location: 1025 State Rte 9 Owner: A2000 Self Storage& Ink Refill Applicant: Monolith Solar Associates LLC This structure may be occupied as a: Solar Panel System No Rafter Upgrades By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the (17.1" j property owner of the responsibility for compliance with Site Plan, /� Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 t Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: SOLAR-000827-2016 Tax Map No: 296.13-1-24.2 Permission is hereby granted to: Monolith Solar Associates LLC For property located at: 1025 State Rte 9 In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: A2000 Self Storage Solar Panel-Commerical $0.00 Owner Address: 1025 State Rte 9 Total Value $0.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Monolith Solar Associates LLC 444 Washington ST Rensselaer,NY 12144 Plans&Specifications Solar Panel System No Rafter Upgrades $ 30.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday, August 2, 2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Towno sbury; Wed d ,August 2, 2017 SIGNED BY: 4for the Town of Queensbury. V Na Director of Building&Code Enforcement Office Use Only ACCESSORY STRUCTURE APPLICATION Received DATE IjZde �i, Tax Map ID TAxMAP to Z�lb. l�' )- Permit No. ZQ Na - 8T4-- a.1t>n -4-60ZONING Permit Fee ee 1y-s-w u—, 051 to HISTORIC SITE _Yes V' No Approvals SUBDIVISION NAME fLot# APPLICANT �n��• � _ /� ^ 1 fA�� /11 SOlur OWNER A Aoo r) ADDRESS ADDRESS us Qn✓1-r . 7 AU Y )-LI VY ! � r.cn � Ali) /c29o•( PHONEI Y VZ�-a.A qq PHONE Qy o23, - /1/ CONTRACTOR 'l/•I on 0 114L <Olay COST OF CONSTRUCTION(ESTIMATECD)n$ � �S,C O� •Oo ADDRESS: q'7 VJK; yVtr4'�"J' S* BUILDING ADDRESS: �C�oe ny -�J/[,�, � Q�ryn<I�u�.� U.JV IC cr,SSc. &c- /U L" /� t yy /a�oY PHONE: .S-( l L/4/Ll aln41N CONTACT PERSON FOR BUILDING&CODES COMPLIANCE "HONE S~I t3 Y Y°I�0�l y TYPE OF CONSTRUCTION Check all that apply Please indicate measurements as required below Boathouse 1n floor sq.fl. o o s Height Boathouse with Sundeck Deck 2Q�6 Detached Garage(#of cars_) Dock 444, TOWN OF Q EEbUKT Pole Bam Porch-open "Porch-3 season, Covered, Enclosed Shed Other Accessory Structure(s) 00tif "' Y "Considered floor area&must comply with FAR(floor area ratio)requirements if located in the WR zone DECLARATION: I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true & complete statement description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances; and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupan I ,/IJI have read and agree to the above: Print Name: O W S v_N Dater 11 2-4)6 Signature: — Date: )I 29 (6 IF ton 1"VO Ir OL Mane u�� $Q„✓) 1 Town of Queensbury Building&Codes Accessory Structure Application July 2014 STATE OF NEW YORK _ �t� L; J DEPARTMENT OF STATE : .I} )' I ANDREW M. CUOMO ONE COMMERCE PLAZAI AUG I� i GOVERNOR 99 WASHINGTON AVENUE fI II '� AUG O 12017 ROSSANA ROSADO ALBANY,NY 12231-0001 WWW.DOS.NY.GOV ,,' j II SECRETARY OF STATE FILE COPY1 In the Matter of the Petition of: DECISION KEITH CRIST For a Variance to the New York State Uniform Fire Prevention& Building Code PETITION NO. 2017-0136 Upon the application of KEITH CRIST, filed pursuant to 19 NYCRR 1205 on April 5, 2017, and upon all other papers in this matter, the Department makes the following determination: NATURE OF GRIEVANCE AND RELIEF SOUGHT The petition pertains to the installation of solar photovoltaic panels on five existing self-storage mini- warehouses, approximately 4,600 square feet each in gross floor area, Occupancy Group S1, Moderate Hazard Storage, 1 story in height, located at 1025 us Route 9, Town of Queensbury, County of Warren, State of New York. Relief is requested from: Section 605.11.1.3,of the 2016 International Fire Code,providing as follows:Access to systems for buildings...shall be provided in accordance with Sections 605.11.1.3.1 through 605.11.1.3.3 [The petitioner requests relief to install solar photovoltaic system panel arrays without access pathways.] FINDINGS OF FACT 1. Proposed plans show solar photovoltaic panels to be installed from edge to edge across the width and length of existing self-storage mini warehouses 2. Section 605.11.1.3.1 requires a minimum 6-foot-wide clear perimeter around the edges of the roof. 3. The existing self-storage buildings are 31 wide and a 6-foot access pathway around the perimeter of the buildings would eliminate two of three rows of proposed solar photovoltaic panels. 4. It is unlikely that the one story building's roof would ever be accessed by the fire department for smoke venting operations and Section 605.11.1.3.3 allows for panel arrays up to 150 feet in distance in either axis and the proposed installation is 30 feet by 149 feet. INII, OF K Department E OFRTUNITY. of State J Petition No 2017-0136 Page 2 CONCLUSION OF LAW The proposed variance will not substantially adversely affect the Code's provisions for health,safety and security. Strict compliance with the provisions of the Uniform Fire Prevention and Building Code would entail practical difficulfies, economic hardship, or would otherwise be unwarranted because such would not achieve it's intended objective or would entail a change so slight as to produce a negligible benefit consonant with the purpose of the code. DETERMINATION WHEREFORE IT IS DETERMINED that the application for a variance from Section 605.11.1.3, of the 2015 International Fire Code, be and is hereby PROPOSED TO BE GRANTED. This DECISION is issued under 19 NYCRR 1205.6. Unless objected to by the petitioner in a writing received by the department the decision shall become FINAL after fifteen days of receipt of the decision by the parties. This decision is limited to the specific building and application before it, as contained within the petition, and should not be interpreted to give implied approval of any general plans or specifications presented in support of this application. �� 4 J n Addario PE, Director ision of Building Standards and Codes DATE: August 1,2017 MC: nc Dec. 29, 2017 .12 ; 27PM MDIR_ No. 1729 a. 2 MIDDLE DEPARTMENT INSPECTION AGENCY', INC. e~l���that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Fort Plain CSD Bus Garage Date: 12/21/2017 Occupant: 2000 Self Storage-System A Location:1025 Route 9 Occupancy-Non-Residential Queensbury, Warren Co- NY Applicant-F � Monolith SolarAssoc.,LLC - 444 Washington Street Rensselaer, NY 12144, Joseph A.Holmes No. _1415391362460EL _ _ _ _ _ - Equipment: - - 152 - Solar Modules; 2 -20,000 Watt Inverters: 1 _Summing Pane;-1 Production Meter, 2 -AC Disconnects; 1 - Utility Meter This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This oerdficate applies only to the use,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy of ownership inspection. No warranty is expressed or implied as to the mechanical safety effi- of the property indicated above,this certificate shall be immediately null and void. ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, I be valid for a period Of one year from the above noted date. Should the electrical this certificate may be ravalidated upon reinspection by Middle Department system to which this certlflcate applies be altered in any way,Including but not limit- Inspection Agency, Inc. An application for inspection must be submitted to Middle ed to,the introduction or additional electrical equipment and/or the replacement of Department Inspection Agency, Inc, to initiate the inspection and revalidation any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. D ECrware JAN 0 5 2018 TOWN OF QUEENSBURY BUILDING&CODES 20 t b -Dec. 29. 201 ),z12 : 28 PM MDIA No. 1129 P, 4 f - MIDDLE DEPARTMENT INSPECTION AGENCY, INC. that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Albany CSD/New Scottland Elm Date' 12/21/2017 Occupant: 2000 Self Storage-System B Location 1025 Route 9 Occupancy Non-Residential Queensbury, Warren Co. NY Applicant: I Monolith Solar Assoc.,LLC 444 Washington Street Y Rensselaer, NY 12144 L J Joseph A.Holmes No- - - - - - - - - 1415391362459EL - Equipment: 304 - Solar Modules, 4 -20,000 Watt-Inverters, 1 Summing"panel; 1---production Meter, 1 - Utility Meter; 2 -AC Disconnects This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. -ibis certificate applies only to the use,occupancy and above and the instaitation inspected as of the above noted date based on a visual owner:hlp as indicated herein. Upon a change in the use,occupancy or ownership inspection. No warranty is exprassed or implied as to the mechanical safety, ef8- of the property indicated above,this certificate shall be immedlately null and vold, clency,or fltre.s of tree equipment for any particular purpose. ells certificate shall In,the event that this certificate becomes invalid based upon the above conditions, be valld for a period of one year from the above noted date. should the electrical this certificate may be revalidated upon reinspsetion by Middle Department system to which this certificate applies be eitered in any way,including but not limit- Inspection Agency, Inc. An appllcavon for Inspection must be submitted to Middle ed to,thB introduction of additional electrical equlpment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation any cf the components installed as of the above noted date,this ceR-rfirate Shzl!ba proeass. A tea will ba charged for this service. p Q�EENSBu�Y T�gU D NG�pES �j\b Dec. 29, 201712: 28PM MBIA No. 1729 P. 5 - MIDDLE DEPARTMEYf INSPECTION AGENCY, INC. �e that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date 1 noted below and is issued subject to the following conditions. Owner: Albany CSD/Montessori School Date- 12/21/2017 Occupant: 2000 Self -Storage System C Location , 9 Y 1025 Route 9 OccupancyNon-Residential Queensbury, Warren Co. NY Applicant; � Monolith Solar Assoc.,LLC 444 Washington Street - Rensselaer, NY 12144 - L— J. Joseph A.Holmes No. 1415�91.3Q2458,EIs - - - - - - - - - - - - - Equipment: 460 - Solar Modules; 6 - 20,000 Watf lhVerteirs; rlg panel; 1 -'Production Meter; 1 - Utility meter, 2 -AC Disconnects This certificate applies to the electrical wiring to the electncsf equipment listed immediately null and void, This cera ficate applies only to the Lisa,occupancy and above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a Change in are use,occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical Safety, effi• of the property Indicated above,this certificate shalt be immediately null and void, ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department system to which this certificate applies be altered in any way,Including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle ed to.the introduction of addiiionaf electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation any of the Components installed ss of the above noted date,NS Certificate shall be process. A fee will be charged for this service. E v E F DV JAN TOWN OF QUEENSBURY BUILDING I FILE COPY 296.13-1-24.1 SOLAR-000827-2016 A2000 Self Storage 1,2000 Self Storage (System A) RoMeWed C-i 1025 State Route 9 - - 1025 U.S. Route 9 Solar Panel System Queensbury, New York 12804 --' J GENERAL NOTES LOCATION MAP PROJECT SCOPE v d S 1. Installation shall comply with the 2015 New York - This project consists of the installation of solar o State Uniform Fire Prevention and Building Code, modules, per the system description, below. The N o 2014 National Electrical Code NFPA 70, the modules will be installed on a roof mounted racking 4 ffi d requirements of the New York State Public Service Project Location system and connected to inverters, which convert m " Commission (PSC),and the electric utility company. the photovoltaic output power from DC to AC. The 19 9 2. All electrical components/equipment shall be solar electric system will be interconnected To The r listed/labeled by a Nationally Recognized Testing utility distribution system with a new electrical 'o Laboratory in compliance with NEC Article 110.3. service in accordance with utility specifications. a 3. All components shall be installed,including wire G_ terminations, in accordance with manufacturer's SHEET# SHEETTITLE instructions. TOWN OF QUEENSBURY T-1 Title Page ,17 4. Equipment shall be labeled in accordance with BUILDING DEPARTMENT NEC Article 690. STRUCTURAL ry 5. All DC conductors shall be copper Based on our limited examination,compliance i PP with our comments shall not be construed as S-1 Site Map a ¢ d 6. All AC conductors shall be aluminum or copper. indicating the plans and specifications are in yr E a S-2 Building 5 Array Layout w d 7. All wires shall be provided with strain relief at all full compliance with the Building Codes of — a entry into boxes as required by UL listing. New York State. ELECTRICAL rn u}'i Z 8. Module frames and rail shall be bonded with o H P 3 E-1 DC/AC Sin le Line Diagram p o equipment grounding conductors. g g 8 9. All GEC connections,taps, and splices shall be AERIAL VIEW E-2 DC Three Line Diagram made with irreversible compression-typeE-a AC three Line Diagram connectors listed as grounding and bonding 1*1� / equipment, or by exothermic welds. system Notes r 10.All Equipment shall be mounted as shown.Where details are not provided,the sub contractor shall j Q �a 2 6 use diligent efforts To mount equipment such that it Pro ecT Location D C L5 D I will be clean,level,and solid. :: 11. No structural member shall be drilled unless approved by EPC. DEC 0 2 2016 12. Conductors shall be re-identified by the following '` F color scheme: r)FSBURY DC Positive: Redll�i DC Negative: Black °s Other conductors shall be in accordance with �� ,� ' system Size 52,000 watts DC/40,000 watts AC National Electrical Code. inverters (2)SE 20K & snee r 13. MC ratings shall meet or exceed The ratings as Modules (160)Trina TSM-PD14 325W calculated and per utility requirements. i 1 �" Monolith Identification A2000 Self Storage(System A) // Proposed 100 KVA X(3)Pole- _ (160)Tdna 325 W Modules. t Ill. Mounted Transformers New Proposed Utility Pole (2)SE20 KW Inverters. 52,000 W DCI40,000 W AC Point Of Interconnection POI -.� Existing 3-Phase Utility Pole U I Meter Pedestal v {M D @ d yy � C J, AC Trench To POI.Trench Is `r -( •4 `o Approximately 200'.Voltage Will Be<1.5%. may,'; •\ m t _A v �J� vi 3 0 At C 0 ` 111W 7 d o Inverted PanelboaM \ •, :' ,. @ ti Pedestal � � O1 Y i•- \ r: a Je L Ae • - - Building 5(180 Modules) _ � �� • e Azimulh:238` Pilch: - - s 4�? :, L • . " - (9)Rovs Of Modules In Landscape Orientation ;1 SILEMAE i a • or S-1 J BUILDING 5- (160) MODULES Z N AZIMUTH: 2380 PITCH: -00 STANDING SEAM N ALL DIMENSIONS TYPICAL FOR ADJACENT MOUNTING a rm PLANES UNLESS OTHERWISE SPECIFIED t 149'•0" O C 3" GAP FOR THERMAL EXPANSION OF RAIL _ 8 W V � Y 31'-4" 29'-9 7/8" i Y ps 251-101/4" 116'-9" i � 142'-8" e 3 Shed 3 S-2 ELECTRICAL EQUIPMENT SCHEDULE SHEET NOTES QUAMITY COMPONENT DESCRIPTION 1 160 SOLAR MODULE TRINA TSM-PD14 325 WATT MODULE 1. ALL DC WIRING SHALL BE 1000V V 2 80 OC TO DC CONVERTER P700 SOLAREDGE POWER OPTIMIZER RATED. � 3 2 DC DISCONNECT SWITCH NEMA 3R, 1000V RATED DISCONNECT SWITCH 2. THE PV SYSTEM IS UNGROUNDED. 4 2 PV INVERTER [2]SE20K-US. 480Y/277V ACR w THE PV SOURCE AND OUTPUT •� � � 5 1 KILO.LOAD CENTER SODA,430Y/277V 3PH,NEMA 3R RATED-[2]40A 3-POLE AND[3]15A 2-POLE BREAKER(S) CIRCUITS SHALL COMPLY WITH NEC N 6 1 PV METER VISION STANDARD XT CLASS 200 PRODUCTION METER 690.35. Q lin c n 7 1 NON-FUSED AC DISCONNECT 100A,3PH,NEMA 3R 600V AC-RATED-NON-FUSIBLE 3. MAXIMUM DC OUTPUT CIRCUIT a 8 1 PV GENERATOR AC DISCONNECT 100A,3PH,NEMA 3R, 600V AC-RATED-60A FUSES POWER IS 9,100 WATTS. MAXIMUM TR 3 51 c 9 1 CELLULAR MODEM-MONITORING OPTCONNECT,5V, 14"X16"PVC ENCLOSURE ALLOWABLE POWER IS 12,750 WATTS. O O MLO Load OPTIMIZER Center RB W of W $MIIg 1.T:[R6]M'IQwH p6CO19 NNECT I$@01[ y 3 s W zl: n Modwei - OC Imalef4 W Y z $M,p 21 Tza]M>dJef OEfANx[Cf mim N M sM 23:1 Modwef 2 3 4 O N fN'f a M O M kWh o Q ° o PV NON-FUSED AC UTILITY PV GENERATOR L g METER DISCONNECT METER AC DISCONNECT a 6 7 g Utility Transformer I E Mdnlldring +fun CeV01tn 5 Modem 9 e Sheet 4 1 DC/AC SINGLE LINE DIAGRAM E-1 Wire and Conduit Schedule SHEET NOTES Location Size Type CCC Ground Conduit 1,ALL DC WIRING SHALL BE 1000V RATED. \ A PV SOURCE CIRCUIT 10 AWG [Cul PV 2 BARE 6 AWG[a]E FREE AIR 2, THE PV SYSTEM IS UNGROUNDED. THE PV B DC OUTPUT CIRCUIT 10 AWG [Cu] PV 2 Io AWG[Cu]EGC 1"SCHEDULE BO PVC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY U C COMBINED STRING CIRCUIT 8 AWG [Cu] PV 2 8 AWG[Cu]EGC 1^EMT WITH NEC 690.35. N D INVERTER OUTPUT CIRCUIT 8 AWG [Cu] THWN-2 3+N 8 AWG[Cu]EGC VEMT 3. STRINGS 1 AND 2 SHALL BE COMBINED a, TOGETHER BY MEANS OF A 1000V DC 30A 'u = RATED Y-CONNECTOR FOR INVERTERS 1 AND 2. Q � ` d L N O N t ¢ 1 2 3 4 O O 26 26 °C�' O 1 �_-o � ` STRING 1.1 + + + + + C C- © rOEE SHEflE S (26 MODULES) _ A _ y+ 3 2E�.nP.�. Inverted Coaeaox m. ormaee mv. - D a + - STRING 1.3 a + 1 (28 MODULES) a Y 1aW Y Q STRING 1.2 S Y nea uwu m y7 0 3 1 2 3 4 O 0 25 26 1 2 3 4 O O 27 28 N N ul 2 y � (26 MODULES) + - - - - + - + - 8 + - - - - + - + A A E u v a + - - + - + + - - + - S + S $1 1111 H Inverter2 Typical of Inverter 1 r IE b S p as 1 DC THREE LINE DIAGRAM snee s E-2 Wire and Conduit Schedule SHEET NOTES Location Size Type CCC Ground Conduit 1.ALL DC WIRING SHALL BE 1000V RATED. D INVERTER OUTPUT CIRCUIT 8 AWG [Cu] THWN-2 3+N a AWG[Cu] EGC 1'EMT •• 2. THE PV SYSTEM IS UNGROUNDED. THE PV E LINE SIDE LOAD CENTER 6 AWG [Cu] THWN-2 3+N 6 AWG[CU] EGC RIGID NIPPLE MM 241 SOURCE AND OUTPUT CIRCUITS SHALL � F UNE SIDE NON-FUSED AC DISCONNECT 2 AWG [AJ] XHHW-2 3+N 8 AWG[cu] EGC 3'SCHEDULE 80 PVC COMPLY WITH NEC 690.35. -'- G UNE SIDE UTILITY METER 2 AWG [AI] XHHW-2 3+N 8 AWG[Cu] EGC RIGID NIPPLE 0A 241v 3. NATIONAL GRID TO DETERMINE H LINE SIDE FUSED DISCONNECT 2 AWG [AI] XHHW-2 3+N N/A 3"SCHEDULE 80 PVC SPECIFICATIONS FOR UTILITY METER AND o I MONITORING INPUT CIRCUIT 14 AWG [Cu] THWN-2 2 14 AWG[Cu]EGC A"EMT TRANSFORMER. Q 'z M - 0 3 � s Q v MLO Locd Cenler 0 D 8(AWG TCU]GEC . — tOINVERSER 1 F G H SEE SHEQEO I� O b %Odetm 11\\11 E f„Teler E Utility Meter cu 0 13 o G M M �_0 I L q N N 0 Q 5 Y LL W E C kWh NON-FUSEECT D AC kWh PVUtility DISCONNGENERATOR I AC DISCONNECT Transformer tV u i- 1R>iet� 6 7 8 w-,A U2 unEnas 5 w,oxxea 9 14'.18.14• PVC ENCLOSURE .S i . b 1 AC THREE LINE DIAGRAM Sheet 6 E-3 296.13-1-24.1 SOLAR-000827-2016 A2000 Self Storage 2000 Self Storage (System B) 1025 State Route 9 . : Solar Panel System v Queensbury,U.S. Route 9 New York 12804 � GENERALNOTES LOCATION MAP PROJECTSCOPE d A d S 1. Installation shall comply with the 2015 New York - This project consists of the installation of solar o an State Uniform Fre Prevention and Building Code, modules, per the system description, below. The o 2014 National Electrical Code NFPA 70,the modules will be installed on a roof mounted racking 4 a; requirements of the New York State Public Service Project Location system and connected To inverters, which convert m Commission (PSC),and the electric utility company. the photovoltaic output power from DC to AC. The '9 3 2. All electrical components/equipment shall be solar electric system will be interconnected to the & listed/labeled by a Nationally Recognized Testing utility distribution system with a new electrical c Laboratory in compliance with NEC Article 110.3. _ service in accordance with utility specifications. c 3. All components shall be installed,including wire a terminations, in accordance with manufacturer's SHEET# SHEETTITLE instructions. T-1 Title Page 4. Equipment shall be labeled in accordance with NEC Article 690. STRUCTURAL S. All DC conductors shall be copper. s-1 Site Map y m 6. All AC conductors shall be aluminum or copper. 7. All wires shall be provided with strain relief at all S-2 Building 3 Army Layout entry into boxes as required by UL listing. S-3 Building 4 Amy Layout w 8. Module frames and rail shall be bonded with o 4 equipment grounding conductors. S-4 Building 5 Array Layout o 9. All GEC connections,Taps, and splices shall be AERIAL VIEW ELECTRICAL made with irreversible compression-typetq E- DC/AC Single Line Diagram connectors listed as grounding and bonding / equipment, or by exothermic welds r E-z DC Three Line Diagram 10.All Equipment shall be mounted as shown.Where Project Location E-s h Li 8 s details are not provided,the sub contractor shall system N t + use diligent efforts to mount equipment such that it s will be clean,level,and solid. 11. No structural member shall be drilled unless ;, DEC 0 2 204S approved by EPC, 11 12. Conductors shall be re-identified by The following TOWN OF QUEENSBURY 5 color scheme: ;I Ill DC Positive: Red \ �� a DC Negative: Black - °s Other conductors shall be in accordance with \ . �Z System Size 104,000 watts DC /80,000 watts AC National Electrical Code. 6 5 13. KAIC ratings shall meet or exceed the ratings as \ I, 1 lnve to s (4)se 2oK Shm r calculated and per utility requirements. „�I f Modules (320)Trina TSM-PD14 325 WT_y '•:@ - �'" - Monolith Identification A2000 Self Storage (System 1 B) (320)Tdna 325 W Modules. ',i Proposed 100 KVA X(3)Pole- 20 KW Inverters. Mounted Transformers New Proposed Utility Pole 104,000 W DC/80,000 W AC Point Of Interconnection POI Existing 3-Phase Wilily Pole Pole#:93-1J _ J V Meter Pedestal � v � u r O n AC Trench To POI.Trench Is n `o Approximately 65'.Voltage Drop 1 � A �• � •:. q Inverter/Panelboard >�'- �` - •. 3 Pedestal � • � .� `� Y � m ' o DC Trench To Building 3.Trench Is ` al4 c Approximately 30'.Voltage Drop WIII Be<1.5%. ♦ `i fele r_ DC Trench To Buildng 4.Trench Is Approximately 30'.Voltage Drop Wll Be<1.5%. bu m p m v moi, N o QJ y- rc V O N O \tel j C' 8 Building 3(88 Modules) Azimuth:238° Pitch: —0° (4)Rows Of Modules In - Building 5(34 Modules) Landscape Orientation - Azimuth:238° -r (9)Roxs ,. Building 4(198 Modules) Of Modules In `! Landscape Orientation - Azimuth:236° A��M Pitch: (9) Modules In N Landscape pea Orientation - i - r $ s ( Sheer 2 BUILDING 3 -(88) MODULES AZIMUTH: 238° PITCH: -0° R u STANDING SEAM v\ N ALL DIMENSIONS TYPICAL FOR ADJACENT MOUNTING & PLANES UNLESS OTHERWISE SPECIFIED N c < ( L q 149'-0" � 3 3" GAP FOR THERMAL y EXPANSION OF RAIL o e 31'-4" - T-4 5/8" to ro o w E o v 13'-2 5/8" tnc o N 142'-8" Bg is Shell 3 S-2 BUILDING 4- (198) MODULES •• AZIMUTH: 238° PITCH: -0° J STANDING SEAM N ALL DIMENSIONS TYPICAL FOR ADJACENT MOUNTING v PLANES UNLESS OTHERWISE SPECIFIED o N N O Z Yp - C S q 149'-0" p 3 N 3" GAP FOR THERMAL s EXPANSION OF RAIL o JI a m 31'-4" 29'-9 7l8" t0 m e �I OO lA n Q 142'-8" t � g t e � a a S_ Sheet a S-3 J BUILDING 5 - (34) MODULES a AZIMUTH: 238* PITCH: -0* STANDING SEAM o ALL DIMENSIONS TYPICAL FOR ADJACENT MOUNTING a PLANES UNLESS OTHERWISE SPECIFIED ; r 149'-0" O c 3 GAP FOR THERMAL EXPANSION OF RAIL _ OI I I m y 5 31'<" - -- - -- - y - - 6e 25'-101/4" - 116'-9" - - - -- - x 142'-8" 5 e S i Shen 5 S-4 ELECTRICAL EQUIPMENT SCHEDULE SHEET NOTES QUANTITY COMPONENT DESCRIPTION 1 320 SOLAR MODULE TRINA TSM-PD14 325 WATT MODULE 1. ALL DC WIRING SHALL BE 1000V u 2 160 DC TO DC CONVERTER P700 SOLAREDGE POWER OPTIMIZER RATED. 3 4 DC DISCONNECT SWITCH NEMA 3R,1000V RATED DISCONNECT SWITCH 4 4 PV INVERTER [4]SE20K-US. 480Y/277V AC 2. THE PV SYSTEM IS UNGROUNDED. THE PV SOURCE AND OUTPUT •D 5 1 M.L.O.LOAD CENTER 200A,480Y/277V 3PH,NEMA 3R RATED-[4] i0A 3-POLE AND[1]15A 2-POLE BREAKER(S) CIRCUITS SHALL COMPLY WITH NEC N C :I 6 1 PV METER VISION STANDARD XT CLASS 200 PRODUCTION METER 690.35. Q rz e 7 1 NON-FUSED AC DISCONNECT 200A,3PH,NEMA 3R, 600V AC-RATED-NON-FUSIBLEw 3. MAXIMUM DC OUTPUT CIRCUIT 8 1 PV GENERATOR AC DISCONNECT 200A,3PH,NEMA 3R, 600V AC-RATED-125A FUSES POWER IS 9,100 WATTS. MAXIMUM 19 535 9 1 CELLULAR MODEM-MONITORING OPTCONNECT,5V, 14"X16"PVC ENCLOSURE ALLOWABLE POWER IS 12,750 WATTS. O O E MLO Load OPTIMtZER Center e+ OC ImerlM m "j $MEp l.t[26]AbtlYleE —iV/J_F- 06CONNFCI SEWK EaOr V1 O SM 1.3: 24 MoemeE y_ ¢ 5 n42.1: 9 Moe eE . oc Imede2 @ d vi SM.,22:[26]MetlWeI "......" 06CONNECI S@OK rrNr lA YI J SM 23: 29 M[EMeE SMW 3.1:JUT Moen O SMEq J.2[26]MotluleE - OC ImMeA �Mn SM J.J: 28 ModWlf ------ - $@Q[ Oell SMng at: 2e Moe eE __ I�I _ oc _ I.tae kWh 0 kWh SW 42:1281 Mod,:E �\ eeCCNNECE SMK EMnr O O 2 SW 4J: ModmeE _._ V .... 4 0�o O <5)7 t `% PV NON-FUSED AC METER DISCONNECT UTILITY Py GENERATOR 8 9 METER AC DISCONNECT g 7 g Utility Transformer r MonibdnR tE.rn CeIIWar 5 Modem 9 i 5 , s 3 Sheer 6 i1 DC/AC SINGLE LINE DIAGRAM E-1 Wire and Conduit Schedule SHEET NOTES Location Size Type CCC Ground Conduit 1.ALL DC WIRING SHALL BE 1000V RATED, A PV SOURCE CIRCUIT 10 AWG [C u] PV 2 BARE 6 AWG[Q) FREE AIR 2. THE PV SYSTEM IS UNGROUNDED. THE PV B DC OUTPUT CIRCUIT 10 AWG [Cu] PV 2 10 AWG[Cu]EGC I-SCHEDULE 80 PVC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY C COMBINED STRING CIRCUIT 8 AWG [Cu] PV 2 BAWG[Cu]EGC 1-EMT WITH NEC 690.35. VI D INVERTER OUTPUT CIRCUIT 8 AWG [Cu] THWN-2 3+N BAWG[CU]EGC I-EMT 3. STRINGS 1 AND 2 SHALL BE COMBINED TOGETHER BY MEANS OF A 1000V DC 30A 'u RATED Y-CONNECTOR FOR INVERTERS 1-4. 0 Q C'oo M Ly A f p 1 2 3 4 O O 25 26 O 1 STRING 1.1 + + + A + + C © rOSEESHEETE`e� (26 MODULES) r _ _ _ 3 mc. Pwovowm/ 2 caxeemenv,�+ Inverter 1 D <arEcwv nr. + wiwrzanv. + + _ STRING 1.3 O) (28 MODULES) m 0 O JE 5 nsenv o STRING 1.2 1 2 3 4 O o 25 26 1 2 3 9 O O 27 28 (26 MODULES) + - - - - + + - + - + - - - c o A A O N + - C + _ + + t 8 5 Inverters 2-4 Typical of Inverter 1 E t . DC THREE LINE DIAGRAM Shen T E-2 Wire and Conduit Schedule SHEET NOTES Location Size Type CCC Ground Conduit 1.ALL DC WIRING SHALL BE 1000V RATED. D INVERTER OUTPUT CIRCUIT 8 AWG [Cu] THWN-2 3+N 8AWG[Cu]EGC 1'EMT �. 2. THE PV SYSTEM IS UNGROUNDED. THE Pv E UNE SIDE LOAD CENTER 1 AWG [Cu] THWN-2 3+N 6 AWG[Cu] EGC RIGID NIPPLE"m lay SOURCE AND OUTPUT CIRCUITS SHALL F UNE SIDE NON-FUSED AC DISCONNECT 2/0 AWG [AI] XHHW-2 3+N 8 AWG[Cu]EGC 3'SCHEDULE 80 PVC COMPLY WITH NEC 690.35. J G UNE SIDE UTILITY METER 2/0 AWG [AI] XHHW-2 3+N a AWG[Cu]EGC RIGID NIPPLE M+ 24y 3. NATIONAL GRID TO DETERMINE H UNE SIDE FUSED DISCONNECT 2/0 AWG [AI] XHHW-2 3+N N/A 3'SCHEDULE 80 PVC SPECIFICATIONS FOR UTILITY METER AND TRANSFORMER. I MONITORING INPUT CIRCUIT 14 AWG [Cu] THWN-2 2 14 AWG[CN]EGC 'H"EMT Q Z `m - Gn 3 «_ e 0 D MLO Load Cerlty CO 6 AWG[Cv]GEC C / — C TO INWRTEMO I� �� F �l SEESHEEIE-2 11\/\ 1.1 N 0—U ProducNon E G H E Meler Utility MehrQJ V13 ?_O i M m 0- 0 a--D I N I I I I I N O d It1�B18p2 - OPV CTV m 5 O—b Q� II L3 20 E K I l2 L2 N y xr II W H N J II L O H � O O p kWh NON-fl15ED AC kWh p ^ II DISCONNECT PV GENERATOR UNfify N p AC DISCONNECT Transformer Q Ll II_ INWRT Ma 6 6 l_ wNcrtrR m B 8 `wim'�s 5 � E mxl[q 9 1Y x 1a 14' PVC ENCLOSURE 9 1 AC THREE LINE DIAGRAM sneer 8 E-3 Site Plan Information )o2S U. S, Q Draw a site plan of the home. Mark the location of relevant objects. Label the mounting planes and draw a North (N)arrow. Indicate North it sk [FILE COPY 7`y FIO C,i Se�r i�,xPrIRS +ems iO k S+v4iY3 Sea,., II /kfsiRoNDA-c r 1 5 F�� � LAI/25(1,e�h� 1 -),e `ID Psx snaw L-0 CL � Linz 1 Stowner Sd� 4-o I t3 r6„ I i 3lr �fl ly �' Co n i~ � ,r TfL�G �`e dor rets Ov1 I o K 211 , / ��H Legend D Distribution Panel FOH Front of House M Meter Location Driveway Driveway 2 I Inverter Location E-Street-j Street D LS Uv 'E, V X Grounding DEC 0 2 2016 296.13-1-24.1 SOLAR-000827-2016 TOWN OF QUEENSBURY A2000 Self Storage BUILDING &CODES 1025 State Route 9 Solar Panel System