Loading...
CC-000090-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 - Community Development-Building& Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000090-2017 Date Issued: Tuesday, May 30, 2017 This is to certify that work requested to be done as shown by Permit Number CC-000090-2017 has been completed. Tax Map Number: 288.-1-53 Location: 1415 State Rte 9 Owner: Northway Outlet LLC,Northway Outlet LLC Applicant: Jan Russell This structure may be occupied as a: Commercial Interior Alterations 2990 s.f. Tenant:Zumiez, Space: 125 By Order of Town Board The Outlets at Lake George West TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: CC-000090-2017 Tax Map No: 288.4-53 Permission is hereby granted to: Zumiez,Inc. For property located at: 1415 State Rte 9 In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Northway Outlet LLC Retail-Mercantile-Alteration $85,000.00 Owner Address: 2700 Westchester AVE,Suite 407 Total Value $85,000.00 Purchase,NY 10577 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications Commercial Interior Alterations 2990 s.f. Tenant:Zumiez,Space: 125 The Outlets at Lake George West $598.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,March 21,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of QueensbbeforjthirW date 4$l Dated at the Town QueensTu arch 21,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Only C_4cnl-cs� Date: March 13 , 2017 — Permit No. Tax Map ID Permit Fee Zone Historic? _Yes X No Ree Fee Subdivision Name Lot# Site Plan# Subdivision# Project Location 1415 State Rt 9, space #125 TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. Thisis,'Kadditi bea permit fee(s). Primary Owners) The Outlets at Lake George West Address � �� � 2700 Westchester Ave . , 4407, Purchase, NY 1057 Phone/Email (914) 253-6500 / robin@rgenoveseandassociates . TC)VVN IT�,�F NSB Applicant Jan C. Russell (Architect) Address 2860 Roscomare Rd. , Los Angeles, CA 90077 Phone/Email (310) 476-2170 / jcraia@roadrunner. com Contractor T.B.D. Address Phone/Email Contact Person for Building& Codes Compliance: Jan Russell Phone 310-476-2170 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration I"floor sf 2"d floor sf Total sf Height Single Family Two-Family Multi-Family (# of units_} Townhouse Business Office Retail -Mercantile X X 2 , 990 17 ' Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 PRINCIPAL STRUCTURE APPLICATION Office Use Only Date: March 9, 2017 Permit No. Q(., 0�0 21 Tax Map ID Permit Fee Qj Zone Historic? _Yes X No $eo-Fee - Subdivision Name _ l C; Lot# Site Plan# Subdivision# Project Location 1-4-_�rl- state Rt 9, space #125 TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) The Outlets at Lake George `���� Address 2700 Westchester Ave . , #407, Purchase, NY 10577 Phone/Email (914) 253-6500 / robin@rgenovesea s ciates .com Applicant Jan C. Russell (Architect) Address 2860 Roscomare Rd. , Los e e T�M077 Phone/Email (310) 476-2 70 / rai roady,unner. om Contractor T.B.D. Address Phone/Email Contact Person for Building & Codes Compliance: Jan Russell Phone 310-476-2170 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration V floor sf 2'14-floor sf Total sF Height Single Family Two-Family MAR 1 11 Lulf Multi-Family E (#of units_) Townhouse Business Office Retail-Mercantile X X 2, 990 17 ' Factory-Industrial Attached Garage (1, 2, 3, 4+) Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business ZUM I E Z Proposed use of building or addition Retail Sales Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys N/A Are there structures not shown on plot plan? No Are there easements on the property? No Site Information: a. Dimensions or acreage of lot 49, 613 (total building area) b. Is this a corner lot? Yes X No c. Will the grade be changed as a result of construction Yes X No d. Public water or Private well (circle one) Public Private e. Sewer or Private Septic System(circle one) Sewer Private Value of all work to be performed (labor or materials) $ 85 , 000 . 00 DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Jan C. Russell DATE: 3/9/17 SIGNATURE: DATE: 3/9/17 For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 COMcheck Software Version 4.0.5.4 Interior Lighting Compliance Certificate Project Information 288--1-53 CC-000090-2017 Energy Code: 90.1 (2013)Standard Zumiez (Outlets @ LG West) Project Title: Zumiez#695 1415 State Route 9, Space 125 Project Type: Alteration Comm. Int. Alterations 2990 s.f. Construction Site: Owner/Agent: Designer/Contractor: The Outlets at Lake George Zumiez HFA Suite#125 1705 S Walton Blvd Suite 3 Lake George, NY 12845 + Bentonville, AR 72712`! r � 9 W E-: I (479)273-7780 Allowed Interior Lighting Power � f ! MAR , 217 TO tr r w!. a iCwlft B C D ) Area Category �� Floor Area Allowed Allowed Watts (ft2) Wafts/ft2 (B X C) 1-Sales Floor(Retail:Sales Area) 2175 1.44 3132 2-Fitting Rooms(Retail:Dressing/Fitting Room) 96 0.71 68 3-Stockroom(Common Space Types:Storage) 415 0.63 261 Total Allowed Watts= 3462 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Sales Floor( Retail•Sales Area 2175 sq ft) Contech:F: 1 per:Quad 4-pin 18W:Electronic: 1 6 18 108 Juno:H: 1 per:Other: Electronic: 1 10 36 360 Vode 2: D1:2 fix:48"T8 25W(Super T8):Electronic: 2 14 56 Exempt Exemption:Furniture-mounted Supplemental Task Lighting Vode:D: 1 fix:48"T8 25W(Super T8):Electronic: 1 2 28 Exempt Exemption:Furniture-mounted Supplemental Task Lighting LED Elcast:A:LBZ-12 FR-LED:Other: 1 10 45 450 LED Track Lighting:B/B1: Wattage based on current limiting device capacity 0 0 1320 1320 Fitting Rooms(Retail:Dressing/Fitting Room 96 sq ft) Wall Sconce:E:PW614:Other: 1 4 36 144 Contech copy 1:F: 1 per:Quad 4-pin 18W:Electronic: 1 3 18 54 Stockroom(Common Space Types•Storage 415 sa ft) Day Brite:VIE:48"T8 28W(Super T8): Electronic: 2 7 64 448 Total Proposed Watts= 2884 Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 1 of 6 NY\Disciplines\Electrical\ComCheckNY.cck Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.0.5.4 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. �At^C03A 1 -4 • 1� Name-Title Signature Date t� Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 2 of 6 NY\Disciplines\Electrical\ComCheckNY.cck COMcheck Software Version 4.0.5.4 Inspection Checklist Energy Code: 90.1 (2013) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Re .ID 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 8.4.1.1, calculations provide all information ❑Does Not 8.4.1.2, with which compliance can beLocation on plans/spec: El, E2, E3 8.7 determined for the electrical systems ❑Not Observable [PR6]2 and equipment and document where ❑Not Applicable exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 9.4.3, 9.7 calculations provide all information ❑Does Not [PR4]1 with which compliance can be ❑Not Observable Location on plans/spec: El, E2, E3, E4 determined for the interior lighting and electrical systems and equipment []Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 3 of 6 NY\Disciplines\Electrical\ComCheckNY.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Recl.ID 8.4.2 At least 50%of all 125 volt 15-and ❑Complies Exception: Space type is not private office, open office, or [EL10]2 20-Amp receptacles are controlled by ❑Does Not computer classroom. an automatic control device. ❑Not Observable ❑Not Applicable 9.4.1.1 Automatic control requirements ❑Complies Requirement will be met. [EL1]2 prescribed in Table 9.6.1,for the ❑Does Not appropriate space type, are installed. ❑Not Observable Location on plans/spec: E1 Mandatory lighting controls(labeled as'REQ')and optional choice controls ❑Not Applicable (labeled as'ADD1' and 'ADD2') are implemented. 9.4.1.1 Independent lighting controls installed ❑Complies Requirement will be met. [EL2]2 per approved lighting plans and all ❑Does Not manual controls readily accessible and Location on plans/spec: E1 visible to occupants. ❑Not Observable ❑Not Applicable 9.4.1.2 Parking garage lighting is equipped ❑Complies Exception: Requirement does not apply. [EL11]2 with required lighting controls and ❑Does Not daylight transition zone lighting. ❑Not Observable ❑Not Applicable 9.4.1.1f Daylight areas under skylights and ❑Complies Exception: Requirement does not apply. [EL13]1 roof monitors that have more than ❑Does Not 150 W combined input power for general lighting are controlled by ❑Not Observable photocontrols. ❑Not Applicable 9.4.1.3 Separate lighting control devices for []Complies Requirement will be met. [EL4]1 specific uses installed per approved []Does Not lighting plans. ❑Not Observable Location on plans/spec: E1, E2, E3 []Not Applicable 9.6.2 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable Location on plans/spec: E1, E2, E3 automatically controlled and separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 4 of 6 NY\Disciplines\Electrical\ComCheckNY.cck Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 6 of 6 NY\Disciplines\Electrical\ComCheckNY.cck COcheck Software Version 4.0.5.4 Interior Lighting Compliance Certificate 288.-1-53 CC-000090-2017 Project Information Zumiez Energy Code: 90.1 (2013)Standard 1415 State Route 9 Project Title: Zumiez Comm. Alt. REVISED PLANS 95 Project Type: Alterationn Construction Site: Owner/Agent: Designer/Contractor: The Outlets at Lake George Zumiez HFA Suite#125 1705 S Walton Blvd Suite 3 Lake George, NY 12845 Bentonville,AR 72712 (479)273-7780 Allowed Interior Lighting Power MAR 16 2017 A B C D Area Category Floor Area Allowed Allowed Wafts (ft2) Wafts/ft2 (B X C) 1-Sales Floor(Retail:Sales Area) 2175 1.44 3132 2-Fitting Rooms(Retail:Dressing/Fitting Room) 96 0.71 68 3-Stockroom(Common Space Types:Storage) 415 0.63 261 Total Allowed Watts= 3462 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Sales Floor(Retail:Sales Area 2175 sq.ft.) Contech:F: 1 per:Quad 4-pin 18W:Electronic: 1 6 18 108 Juno:H:1 per:Other:Electronic: 1 10 36 360 Vode 2:D1:2 fix:48"T8 25W(Super T8):Electronic: 2 14 56 Exempt Exemption:Fumiture-mounted Supplemental Task Lighting Vode:D: 1 fix:48"T8 25W(Super T8):Electronic: 1 2 28 Exempt Exemption:Fu m itu re-mou nted Supplemental Task Lighting LED Elcast:A:LBZ-12 FR-LED:Other: 1 10 45 450 LED Track Lighting:B/B1: Wattage based on current limiting device capacity 0 0 1320 1320 Fitting Rooms(Retail:Dressing/Fitting Room 96 sq.ft.� Wall Sconce:E:PW614.Other: 1 4 36 144 Contech copy 1:F: 1 per:Quad 4-pin 18W:Electronic: 1 3 18 54 Stockroom(Common Space vDes:Storage 415 sq.ft.) Day Brite:I/IE:48"T8 28W(Super T8):Electronic: 2 7 64 448 Total Proposed Watts= 2884 Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 1 of 6 NY\Disciplines\Electrical\ComCheckNY.cck Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2013)Standard requirements in COMcheck Version 4.0.5.4 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Zumiez#695 Report date: 03/03/17 Data filename: \\hfa-file0l\2017 Projects\06\06-17-50004 Zumiez-Lake George, Page 2 of 6 NY\Discipli nes\Electrical\ComCheckNY.cck FIRE MARSHAL'S OFFICE Tozun of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Zumiez 1415 Route 9 CO-000090-2017 3/14/2017 The following comments are based on review of the submitted plan: 1) Locks / latches shall comply with chapter 10 of the 2015 International Fire Code. 2) Verify location/operation of exit/ emergency lights 3) Verify Fire Extinguisher locations. 4) Carbon monoxide detection required. 5) A Knox Box is required- section 506 of the IFC 6) Fire alarm system requires witness test by FM, along with NFPA 72 compliant documents. 7) Any modifications of the sprinkler system will require an NFPA 13 compliance letter 8) Rear egress path shown does not comply with 2015 IFC, Chapter 10, Section 1016.2, Exception 2. Partial or full height walls will be required Fire Marshal Michael J Palmer Fire Marshal 518 761 8206 firemarshal@queensbury.net Fire Marshal 's Office - Phone: 518-761-8206 - Fax: 518-745-4437 firemarshal@queensbunj.net - zmviv.queensbunt.net Northeastern Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 HVAC SYSTEMS TESTING: s�.. v_. r.....__ ._._,....._.... ._._._._.,.:...m,.w ._. Air Balance Report f,4AN t 66 2017 TV`VV'14 Chi=O Jiwi=»"SSURY Project: Zum leZ Location: Lake George, New York Architect: Jan C. Russell, AIA Los Angeles, California Engineer: Harrison French Bentonville, Arkansas Piping: Sheet Metal: Glens Falls Metal Fabricators, Inc. Fort Edward, New York Date: May 10, 2017 Prepared by: R. Kelley RKelleyC@NortheasternAirQuality.com CERTIFICATION PROJECT: Zuzniez ADDRESS: Lake George, New York THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEM"AND THE PROJECT SPECIFICATIONS. TESTING AND BALANCING FIRM: Northeastern Air Quality, Inc. #3159 CERTIFIED BY: Robert V. Kelley DATE: 5/10/2017 SIGNATURE: ct Air :f Page 2 Northeastern Air Quality,Inc. ABBREVIATIONS P.O.Box 3271,Albany,NY 12203-0271 (518)857-3641 PROJECT: Zumiez THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: ABBREVIATION MEANING ABBREVIATION MEANING A AMPS or AMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC(EFFECTIVE FREE)AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SPS STATIC PRESSURE SENSOR DISCH DISCHARGE SR SUPPLY REGISTER DPR DAMPER TC TEMPERATURE CONTROL AP PRESSURE DIFFERENTIAL TCC TEMPERATURE CONTROL CONTRACTOR EC END CAP TCD TEMPERATURE CONTROL DAMPER ER EXHAUST REGISTER TP THERMALLY PROTECTED FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TRAV DUCT TRAVERSE FLA FULL LOAD AMPS V VOLTS or VOLTAGE FTR FINNED TUBE RADIATION VAR VARIABLE GPM GALLONS PER MINUTE VBD V-BELT DRIVE HP HORSEPOWER VD VOLUME DAMPER LD LINEAR DIFFUSER VEL VELOCITY LF LINEAR FEET(NOMINAL) W WATTS or WATTAGE NA NOT ACCESSIBLE WG WALL GRILLE ND NO DAMPER WMS WIRE MESH SCREEN NDRG NON-DUCTED RETURN GRILLE WR WALL REGISTER NG NO GAUGE ZD ZONE DAMPER NI NOT INSTALLED NIC NOT IN CONTRACT Page 3 Northeastern Air Quality,Inc. AIR TERMINAL BOX CALIBRATION REPORT P.O.Box 3271,Albany,NY 12203-0271 PROJECT: ZumieZ (518)857-3641 TESTED BY: R. Kelley Date: 5/10/2017 REMARKS: UNIT UNIT UNIT DESIGN DDC MEAS'D CALIBR FINAL %OF SYSTEM NUMBER LOCATION TYPE SIZE MAX MIN CFM CFM FACTOR MAX MIN DES MAX DATE REMARKS 1 Sales Ceiling VA 16" 3800 200 3000 2,959 3800 600 100% 5/10/2015 1.8"WC Page 4 Northeastern Air Quality,Inc. GRILLE, REGISTER& DIFFUSER REPORT P.O.Box 3271,Albany,NY 12203-0271 PROJECT: Zumiez (518)857-3641 TESTED BY: R. Kelley DATE: 5/10/2017 REMARKS: DESIGN INITIAL INTERMEDIATE FINAL %OF NO. LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS VAV-1 5110117 1 Sales 12"x 10" 1 500 330 372 487 97% 5/10/17 2 Sales 12"x 10" 500 1 330 372 493 99% 1 5/10/17 3 Sales 12"x 8' 350 231 372 511 146% 5/10/17 4 Sales 12"x 8' 350 230 372 497 142% 5/10/17 5 Stockroom 12"x 6" 300 245 198 293 98% 5/10/17 6 Stockroom 12"x 6" 1 125 143 83 122 98% 5/10/17 7 Bathroom 12"x 12" 75 26 49 73 97% 5/10/17 8 Sales 12"x 6" 250 1 165 165 256 102% 5/10/17 9 Sales 12"x 6" 250 165 165 243 97% 5/10/17 10 Sales 12"x 6" 250 165 165 254 102% 5/10/17 11 Sales 12"x 6" 250 165 165 260 104% 5/10/17 12 Sales 12"x 6" 300 198 198 310 103% 5/10/17 13 Sales 12"x 6" 300 198 198 305 102% 5/10/17 Total 3800 1 4104 108% 5110117 EF-1 14 Bathroom 100 Hood 122 Hood 122 122% 5/10/17 Page 5 Northeastern Air Quality, Inc. Duct Traverse Totals P.O. Box 3271, Albany, NY 12203-0271 PROJECT: Zumiez (518) 857-3641 DATE: 5/10/2017 System Area DESIGN REQUIRMENT Without Blower With Blower STATIC Zone or Branch Duct Size Sq.Ft. VEL CFM VEL CFM VEL CFM PRESSURE DATE T-1 INTO VAV 16" 1.40 2,723 3,800 2120 2,959 2120 2,959 1.8"we 5/10/2017 T-2 Front Branch 18" 1.8 962 1700 842 1,487 958 1,692 1.4"we 5/10/2017 T-3 Rear Branch 20" 2.2 963 2100 636 1,387 975 2,126 1.6"wc 5/10/2017 Page 6 Northeastern Air Quality, Inc. INSTRUMENT CALIBRATION REPORT P.O. Box 3271,Albany, NY 12203-0271 (518)857-3641 INSTRUMENT Model Number SERIAL NO. CALIBRATION I Calibration Company Used on DATE This Job Air Data Multimeter ADM 860C M12033 10/14/2016 Shortrid e Instruments ❑ Air Data Multimeter ADM 860C M05339 9/9/2016 Pro-Calibration, LLC ❑ Air Data Multimeter ADM 860C M11389 8/9/2016 Shortrid e Instruments El Air Data Multimeter ADM 860C M11390 9/22/2016 Pro-Calibration, LLC ❑ Air Data Multimeter ADM 860C M11602 8/10/2016 Shortridge Instruments ❑ Air Data Multimeter ADM 860C M85020 11/9/2016 Pro-Calibration, LLC ❑ Ashcroft Compound Gauge 451279SS02L301MV60 8966484 3/8/2017 FLW Service Corp. ❑ Digital Thermometer SH66A C390105 3/8/2017 Pro-Calibration, LLC ❑ Wrist Reporter WR-301, Thumbswitch 6C00761 12/15/2016 Evergreen Telemetry ❑ Wrist Reporter WR-301, Thumbswitch 6C00765 12/5/2016 Evergreen Telemetry ❑ Evergreen Telemetry Humidity Sensor S-H-3-5" 1500349 10/21/2016 Evergreen Telemetry ❑ Evergreen Telemetry Humidity Sensor S-H-3-5" 1500350 10/21/2016 Evergreen Telemetry ❑ Evergreen Telemetry Humidity Sensor S-PVF-1 1400228 9/15/2016 Evergreen Telemetry ❑ Evergreen Telemetry Humidity Sensor S-PVF-1 1400227 9/15/2016 Evergreen Telemetry ❑ Extech Psychrometer/IR HD500 10068630 2/28/2017 Pro-Calibration, LLC ❑ Extech Tachometer Counter 461920 10117290 10/15/2015 Pro-Calibration, LLC ❑ Extech Tachometer Counter 461920 11090557 12/16/2016 Pro-Calibration, LLC ❑ Extech Tachometer Counter 461920 11107409 12/6/2016 Pro-Calibration, LLC ❑ Flow Hood 8400 N/A N/A ❑ Fluke Clamp Meter 36 76955526 2/28/2017 Pro-Calibration, LLC ❑ Fluke Clamp Meter 335 98500048 3/15/2017 Pro-Calibration, LLC ❑ Fluke Clamp Meter 373 18280380 3/8/2017 Pro-Calibration, LLC ❑ Fluke Air Temperature Probe 80PK-1 N/A 10/6/2016 Pro-Calibration, LLC ❑ Fluke Air Temperature Probe 80PK-24 N/A 3/15/2017 Pro-Calibration, LLC ❑ Fluke K-J Digital Thermometer 51JK 74350232 10/6/2016 Pro-Calibration, LLC ❑ Fluke Temperature Humidity Meter 971 99440781 10/6/2016 Pro-Calibration, LLC ❑ Hot Wire Anemometer 6036-OG 400184 11/25/2016 Kanomax Japan, Inc. ❑ Hydro Data Multimeter HDM250 W13021 11/3/2016 Shortrid e Instruments ❑ Hydronic Manometer HM670 71043005 12/29/2016 Pro-Calibration, LLC ❑ H dronic Manometer IHM670 70742055 1 1/6/2017 Pro-Calibration, LLC ❑ Leak Detective Ventury Flow Meter LDTS-4 7056-4 5/1/2013 McGill Air Flow LLC ❑ Page 7 ❑ Leak Detective Ventury Flow Meter LDTS-3 7055-3 5/1/2013 McGill Air Flow LLC ❑ Quattro-Gas Alert QT-XWHM QA112-05111 3/24/2017 Pro-Calibration, LLC Solar Meterix Pressure Gauge WEISS DUGY2-060-4L 11/7/2013 Pro-Calibration, LLC ❑ TSI Rotating Vane Anemometer RVA801 A03565 3/15/2017 Pro-Calibration, LLC ❑ Page 8