Loading...
RC-000463-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000463-2017 Date Issued: Monday, December 18, 2017 This is to certify that work requested to be done as shown by Permit Number RC-000463-2017 has been completed. Tax Map Number: 308.8-1-74 Location: 92 BURNT HILLS DR Owner: Michaels Group Homes,LLC Applicant: Michaels Group Homes,LLC This structure may be occupied as a: SFD 1939 s.f.,Garage 493 s.f. LARIC development Lot 5 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 01W Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000463-2017 Tax Map No: 308.8-1-74 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 92 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvce of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $200,000.00 Owner Address: 10 Blacksmith DR Total Value $200,000.00 Malta,NY 12020 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 10 Blacksmith DR Malta,NY 12020 Plans&Specifications SFD 1939 s.f.,Garage 493 s.f. LARIC development Lot 5 $1,311.75 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,August 9,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Qu(9 j tnes a , for,2017 SIGNED BY: the Town of Queensbury. Director of Building&Code Enforcement PRINT CIPAL STRUCTURE APPLICATION Office Use Only Date: `7 Lt 4'I 17 `i 1' I ltermitNO. Tax M (ZC—Opd (03 /� Map ID 3US5 . ( ��' + i . -— f Pernit F ee (¢l 7 Zone Htstoric?: so I Ree Fee �S 0 , 00 Subdivision Name 13u9ArT K4bcitE:(L-o 1C-) Lot#_� Site Pi S riision# )r-,v®i t. 2LC'+- Project Location 91 vowft r V%ILL41>qvyE TOWN 80.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums, townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit feels). Primary Owner(s) C_ A` AddressS Ctizsa�� }�C4 1 LA—c— ( MarztotsS t.3e.! MEGFtA,N.LcvltLe , N�f tZl tY3 Phone/Email SL�3 .e�`L .to3il Applicant S(.rt-tic As p.r3rY.J� Address Phone/Email Contractor Sa anc 4"_ Address Phone/Email Contact Person for Building&Codes Compliance: Phone b5-) .3144- TYPE 3144TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration In floor sf 2nd floor sf Total sf Height i Single Family x 00M 1212 1 i9 69 `r 2.14 Two-Family Multi-Family (#of units Townhouse Business Office Retail -Mercantile Factory-Industrial Attached Garage i (1, 2©3, 4+) %4 4413 1t Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) a Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances &Chimneys Are there structures not shown on plot plan? Np Are there easements on the property? K0 Site Information: a. Dimensions or acreage of lot b. Is this a come?lot? _Yes _�No c. Will the grade be changed as a result of construction _Yes No d. Public water or Private well(circle one) ublic Private e. Sewer or Private Septic System (circle one) Server rivate Value of all work to be performed (labor or materials) $ o0 0010 DECLARATION.- 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to pro-vide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: / PRINT NAND: c.//4>ti �b C 4S Uo DATE: _ 01 /I SIGNATURE: A//�/ �� DATE: / For office use only Operating Permit Issued: _Yes —No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Onlv Received DATE: -1124) 1-7 Tar Map ID TAx MAP ID: Permit No. ZONE: Permit Fee APPLICANT l`1kCA4C,trzMA> WJE,.\ , t1...0 PHONE/E-MAIL ADDRESS 1 M.4Ce1on>.S Wqf (Jic2Fk/W\LVil.tt t�lY IZtI@t INSTALLER/ CH b.tt.�tS ¢iGl�t�f 1�tV EYCAk 4 A-n KLc, PHONE/E-MAIL 5k1b . A-7 . BUILDER OWNERM1L}{A�EI.s C'y f�-dsA tiG►A�S ,u,.C 547 .09 q .to 3)I ADDRESS CONTACT PERSON FOR BUIIAING&CODE COMPLIANCE: 1'OI`IY LC C.Prc>U c> PHONE/E-MAIL $57 .1,144- RESIDENCE 144RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom I =total Daily flow 1980 or older Garbage grinder installed _Yes>, No 1981-1991 i Spa or Hot Tub installed _Yes '--No 1992-Present 1j 1 1 0 3 3 ID PARCEL INFORMATION Topography Flat rolling _Steep slope _%Slope Soil Nature I _Sand _Loam _Clay _Other Groundwater I At what depth: Bedrock/Impervious material 2Atwhat depth: Domestic Water Supply Municipal _Well(if well water suppty from any septic system absorption is_R) Percolation Test per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEiVt FOR NEW CONSTRUCTION Tank size LPCO gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with F#2 stone Total length )� O ft.;Each Trench SO Seepage Pit with.#3 stone How many: _;Size A Itemative System Bed or other type: Holding Tank System Total required capacity? Tank size 4 of tanks Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: w{ L C�a C 1 u DATE: SIGNATURE: H DATE: Town of Queensbury Building Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERIYIIT Date: -112.41-1 Applicant Name: M%c`"AA—Ls 4zo1,a Telephone No_: ® . erlq .to 3t t Address to be Inspected %LOOW 11w6 MAV CE Return Address: I ""—r"tts t4A,Y, M�—cy�<y,�� 11t �� 3 Nse izel$ Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: O Final Approval O Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes principal Structure Application Revised January 2016 Aii6 0 1 2017 92 Burnt Hills Dr HVAC Load Calculations for The Michaels Group FIL =COPY [El r, 11t� fitwivorivi R� R "6, HVAC LOADS 0 N w M J M J M O tnLn U O d C d = J M O rn w = w h y ar M Prepared By: 0O 3 NickAbrunza 00 Vcnm � AppoloHeating M � � 868 Burdeck St Schenectady Ny 12306 Friday, July 21, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. ;i Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 92 Burnt Hills Dr Schenectady NY 12306 Page 2 Project Report _ General Project Information —� Project Title: 92 Burnt Hills Dr Designed By: The Michaels Group Project Date: Tuesday, July 18, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data Reference City: Schenectady, New York Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 993 CFM Per Square ft.: 0.328 Square ft. of Room Area: 3,026 Square ft. Per Ton: 1,491 Volume (ft'): 25,215 Building Loads Total Heating Required Including Ventilation Air: 53,822 Btuh 53.822 MBH Total Sensible Gain: 21,542 Btuh 88 % Total Latent Gain: 2,804 Btuh 12 % Total Cooling Required Including Ventilation Air: 24,346 Btuh 2.03 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J Bth Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\92 Burnt Hills Dr.rh9 Friday, July 21, 2017, 1:29 PM y Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 92 Burnt Hills Dr Schenectady,NY 12306 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb _ Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor. 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 155 CFM 80 CFM Infiltration Actual: 0.370 AC/hr 0.190 AC/hr Above Grade Volume: X 25.215 Cu.ft. X 25,215 Cu.ft. 9,330 Cu.ft./hr 4,791 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 155 CFM 80 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(155 CFM), Construction:Average Summer Infiltration Specified: 0.190 AC/hr(80 CFM), Construction: Average C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\92 Burnt Hills Dr.rh9 Friday, July 21, 2017, 1:29 PM s Rhvac•Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 92 Burnt Hills Or Schenectady, NY 12306 Page 4 Load Preview Report MI Min Sys SyI Sys No 0., Sen La Ne Sen Duc scope To /roti Are Gal Gal Gal Loss Htg Clg Htg FM1gj FM SIZE p CFM CFM CFMI CFM CFM Building 2.03 1,491 3,026 21,542 2,804 24,346 53,822 709 993 709 993 993 System 1 2.03 1,491 3,026 21,542 2,804 24,346 53,822 709 993 709 993 993 12x1 Zone 1 3,026 21,542 2,804 24,346 53,822 709 993 709 993 993 12x1 1-Basement 1,024 1,911 420 2,331 11,13E 147 88 147 88 88 1-5 2-Dining 143 1,785 151 1,936 5,224 69 82 69 82 82 1-5 3-Great Roam 337 2236 181 2,417 6,605 87 103 87 103 103 1-6 4-wtchen 186 1,110 72 1,182 2,627 35 51 35 51 51 1 5-Powder Room 30 418 13 431 464 6 19 6 19 19 1 6-Mud Room 58 834 65 899 1,791 24 38 24 38 38 1-4 7-Foyer 76 911 96 1,007 2,328 31 42 31 42 42 1J 8-Home Office 186 1,605 110 1,715 3,904 51 74 51 74 74 1-5 9-Master Bedroom 306 3,053 734 3,787 5,697 75 141 75 141 141 2- 10-Bedroom3 168 2265 399 2,664 3,806 50 104 50 104 104 1-6 11-Laundry 73 904 53 957 1,816 24 42 24 42 42 1--0 12-Bedroom2 166 2,008 399 2,407 3,506 46 93 46 93 93 1-6 13-Loft 81 553 0 553 764 10 26 10 26 26 1-A 14-Bab 1 67 773 26 799 1,184 16 36 16 36 36 1--4 15-Master Sath 125 1,175 85 1260 2,970 39 54 39 54 54 1 I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\92 Burnt Hills Dr.rh9 Friday, July 21, 2017, 1:29 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 92 Burnt Hills Dr Schenectady,NY 12306 Page 5 Duct Size PreviewRom x inimuJJ1,,I� Duct ame Source MVeIM4 MVelool Fac�lh OLn1q Loss! VelgI SP d L.rgct9 Hlg Ci9 Aol. Duce (. _.. _ Y i � 4 Flow Flow Flow I Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 646 147 88 88 1- 2-Dining Built-In 450 750 0.01 0.1 603.3 69 82' 82 1- 3-Great Room Built-In 450 750 0.01 0.1 524.7 87 103. 103 1 4-Kitchen Built-In 450 750 0,01 0.1 586.1 35 51 51 1-4 5-Powder Room Built-In 450 750 0.01 0.1 220.8 6 19 19 1 6-Mud Room Built-In 450 750 0.01 0.1 440.6 24 38. 38 1-4 7-Foyer Bulli-In 450 750 0.01 0.1 480.8 31 42. 42 1-4 8-Home Office Built-In 450 750 0.01 0.1 542.5 51 74, 74 1-5 9-Master Bedroom Built-In 450 750 0.01 0.1 515.8 75 141 141 2- 10-Bedroom 3 Built-In 450 750 0.01 0.1 531.7 50 104 104 1-6 11-Laundry Built-In 450 750 0.01 0.1 477.4 24 42- 42 1-4 12-Bedroom 2 Built-In 450 750 0.01 0.1 471.2 46 93 93 1 13-Loft Built-In 450 750 0.01 0.1 292.3 10 26' 26 1 l"am 1 Built-In 450 750 0.01 0.1 408.1 16 38: 36 1 15-Master Bath Built-In 450 750 0.01 0.1 620.4 39 54- 54 1 Other Ducts In System 1 Supply Main Trunk Built-In 650 900 0A03 0.1 794.1 709 993 993 12x1 Summary System 1 Heating Flow: 709 Cooling Flow: 993 ` I CAUsers\nicka\Documents\Elite Software\Rhvac 9 Projects\92 Burnt Hills Dr.rh9 Friday, July 21, 2017, 1:29 PM Rhvac-Residential$Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 92 Burnt Hills Dr Schenectady, NY 12306 Page 6 Total Building Summary Loads Component Area Sen Let Sen Total Description Quart Loss Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 272.6 5,832 0 3,397 3,397 Pella Slider: Door-Slider 40.8 845 0 282 282 Fire Rated: Door-Fire Rated 21 246 0 82 82 Front Door TMG: Door-TMG Entry 21 246 0 82 82 12E-Obm:Wall-Frame, R-19 insulation in 2 x 6 stud 889.2 6,319 0 768 768 cavity, no board insulation, brick finish, metal studs 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2148.4 9,633 0 1,716 1,716 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 986.1 1,770 0 1,205 1,205 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1024 1,766 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1649.1 12,609 0 2,194 2,194 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-01p: Floor-Over enclosed crawl space, No insulation 352.6 2,914 0 507 507 on exposed walls, sealed or vented space, passive, no floor insulation, the or vines Subtotals for structure: 42,180 0 10,233 10,233 People: 4 1,200 1,600 2,800 Equipment: 0 0 0 Lighting: 2480 8,457 8,457 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 155, Summer CFM: 80 11,642 1,604 1,039 2,643 Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 213 213 Total Building Load Totals: 53,822 2,804 21,542 24,346 Check Figures Total Building Supply CFM: 993 CFM Per Square ft.: 0.328 Square ft. of Room Area: 3,026 Square ft. Per Ton: 1,491 Volume(fN): 25,215 Building Loads Total Heating Required Including Ventilation Air: 53,822 Btuh 53.822 MBH Total Sensible Gain: 21,542 Btuh 88 % Total Latent Gain: 2,804 Btuh 12 % Total Cooling Required Including Ventilation Air: 24,346 Btuh 2.03 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\92 Burnt Hills Dr.rh9 Friday, July 21, 2017, 1:29 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 92 Burnt Hills Dr Schenectady NY 12306 _ Pae 23 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Let Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 1,024 11,136 147 1-5 646 1,911 420 88 88 2 Dining 143 5,224 69 1-5 603 1,785 151 82 82 3 Great Room 337 6,605 87 1-6 525 2,236 181 103 103 4 Kitchen 186 2,627 35 1-4 586 1,110 72 51 51 5 Powder Room 30 464 6 1-4 221 418 13 19 19 6 Mud Room 58 1,791 24 1-4 441 834 65 38 38 7 Foyer 76 2,328 31 1-4 481 911 96 42 42 8 Home Office 186 3,904 51 1-5 543 1,605 110 74 74 9 Master Bedroom 306 5,697 75 2-5 516 3,053 734 141 141 10 Bedroom 3 168 3,806 50 1-6 532 2,265 399 104 104 11 Laundry 73 1,816 24 1-4 477 904 53 42 42 12 Bedroom 2 166 3,506 46 1-6 471 2,008 399 93 93 13 Loft 81 764 10 1-4 292 553 0 26 26 14 Bath 67 1,184 16 1-4 408 773 26 36 36 15 Master Bath 125 2,970 39 1-4 620 1,175 85 54 54 System 1 total 3,026 53,822 709 _ 21,542 2,804 993 _993 System 1 Main Trunk Size: 12x15 in. Velocity: 794 ft./min Loss per 100 ft.: 0.096 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.03 88%/12% 21,542 2,804 24,346 f Actual: 2.40 75%/25% 21,600 7,200 28,800 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B-' 13ACXN030-230-" Indoor Model: C35-24B+TDR+TXV Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 28,800 Btuh Sensible Capacity: n/a 21,600 Btuh Latent Capacity: n/a 7,200 Btuh AHRI Reference No.: n/a 8269470 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\92 Burnt Hills Dr.rh9 Friday, July 21, 2017, 1:29 PM REScheck Software Version 4.6.2 n Compliance Certificate M y O J M O U) u7 14* Project The Kimball oE o m U p J M Energy Code: 2015 IECC = CU Location: Warren County, New York CL IC) 0 Construction Type: Single-family p N ,F Project Type: New Construction = uj Conditioned Floor Area: 1,939 ft2 T Glazing Area 14% FILE COPYE M Climate Zone: 6 (8499 HDD) Permit Date: 17 July, 2017 Zm Permit Number: O U O '— N L- M �2mfn Construction Site: Owner/Agent: Designer/Contractor: 92 Burnt Hills Drive Michaels Group Homes, LLC Queensbury, NY 1 Marions Way Mechanicville,NY 12118 e: Passes using UA trade-off Compliance: 1.3%Better Than Code Maximum UA: 299 Your UA: 295 REVIEWED FOR The%Better or Worse Than Code Index reflects how dose to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. ENERGY CODE COMPLIANCE Envelope Assemblies Gross Area Cavity Cont Assembly or R-Value R-Val u, U-Factor UA Perimeter Foundation Wall:Solid Concrete or Masonry 1,247 0.0 19.0 0.038 47 Wall height: 8.6' Depth below grade: 7.6' Insulation depth:8.6' 1x 5030 Sliding Windows:Vinyl Frame:Double Pane with Low-E 15 0.300 5 2x Std.Basement Window:Vinyl Frame:Double Pane with Low-E 4 0.300 1 1st Floor Walls:Wood Frame,24"o .c. 1,305 21.0 0.0 0.056 60 Foyer#1: Solid 21 0.170 4 2x Home Office(D):Vinyl Frame:Double Pane with Low-E 36 0.300 11 lx Stair(AC):Vinyl Frame:Double Pane with Low-E 4 0.300 1 2x Great Room (E):Vinyl Frame:Double Pane with Low-E 29 0.300 9 1x Great Room (R):Vinyl Frame:Double Pane with Low-E 27 0.300 8 #7 Breakfast: Glass 40 0.300 12 2x Dining (C):Vinyl Frame:Double Pane with Low-E 21 0.300 6 1x Dining (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 1x Mud(AC):Vinyl Frame:Double Pane with Low-E 4 0.300 1 Mud#20: Solid 19 0.170 3 2nd Floor Walls:Wood Frame, 24" o.c. 1,016 21.0 0.0 0.056 51 Project Title: The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 1 of 10 Gross Area Cavity Cont. Assembly or U-Factor UA 2x Bed#3 (AT):Vinyl Frame:Double Pane with Low-E 32 0.300 10 1x Master Bed (G): Vinyl Frame:Double Pane with Low-E 32 0.300 10 1x Master Bath I%Vinyl Frame:Double Pane with Low-E 12 0.300 4 1x Master Bath (AC):Vinyl Frame:Double Pane with Low-E 4 0.300 1 Ix Main Bath (AC):Vinyl Frame:Double Pane with Law-E 4 0.300 1 1x Bed#2 (AT):Vinyl Frame:Double Pane with Low-E 16 0.300 5 1x Laundry(AS):Vinyl Frame:Double Pane with Low-E 10 0.300 3 Ceiling: Raised or Energy Truss 1,111 38.0 0.0 0.025 28 Floor Above Garage:All-Wood Joist/Truss:Over Unconditioned Space 115 30.0 0.0 0.033 4 Laundry Floor Above Porch:All-Wood Joist/Truss:Over Outside Air 14 30.0 0.0 0.033 0 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. eew�J T)'Q- 4 i Pr�stDsE� tr IQ I vl t'1 Name-Title Signat -,� O Date 2 \ a p 068319 v4'� k0 SS10�P Project Title:The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions' column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions &Reci.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the J, building envelope.Thermal [-]Not Observable envelope represented on []Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. []Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACOA Manual S based Btu/hr Btu/hr— []Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable J Manual J or other methods Btu/hr Btu/hr _ approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 3 of 10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &R .ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F0411 insulation R-value.Where interior R- R_ ❑Does Not table for values. insulation is used. verification ❑No[Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ;,❑Complies [F0511 insulation installed per 1$❑Does Not manufacturer's instructions. *^❑Not Observable {❑Not Applicable 402.2.9 Conditioned basement wall _ft _ft ❑Complies See the Envelope assemblies [F0611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F01112 to protect exposed exterior ❑Does Not 14 insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F01212 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Ter 2) 3 1 Low Impact Mer 3) Project Title:The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 4 of 10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 []Not Observable 0 []Not Applicable 402.1.1, Glazing U-factor(area-weighted U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 []Not Applicable [FR211 a 303.1.3 U-factors of fenestration products ❑Complies (FR4]1 are determined in accordance []Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies (FR2311 installed per manufacturer's ❑Does Not 0 instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2011 is listed and labeled as meeting ❑Does Not 0 AAMA/WDMA/CSA 101/1.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR1211 insulated >= R-8 where duct is ❑Does Not >=3 inches in diameter and >= ❑Not Observable R-6 where<3 inches.Supply and return ducts in other portions of ❑Not Applicable the building insulated >=R-6 for diameter>=3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not 0 []Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R-_ ❑Complies (FR1712 above 105 QF or chilled fluids []Does Not dJ below 55 QF are insulated to a:R- ❑Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. []Does Not 4-41 ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R-_ R-_ ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are !❑Complies [FR19]2 installed on all outdoor air j❑Does Not intakes and exhausts. I❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 5 of 10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 7 2 FMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title:The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Re .ID 303.1 All installed insulation is labeled ❑Complies [IN13]' or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN111 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN211 in substantial contact with the ❑Not Observable underside of the subfloor,or floor framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R-_ ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least'A of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass (-]Not Observable [IN311 exterior, the exterior insulation g, requirement applies(FR10). ❑ Steel ❑ Steel []Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. ❑Does Not []Not Observable []Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 ILowlmpact(Tier 3) Project Title: The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 7 of 10 Section Plans Verified Field Verified # Final Inspection Provisions & Re .ID I Value Value Complies? Comments/Assumptions 402.1.1, Ceiling insulation R-value. R-_ R-_ ❑Complies See the Envelope assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. []Does Not [FI211 Blown insulation marked every []Not Not Observable ❑No[Applicable 402.2.3 Vented attics with air permeable ❑Complies [F12212 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- _ R-_ ❑Complies [F1311 insulation aR-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50=_ ACH 50 =_ ❑Complies [FI1711 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 dm/100 cfm/100 ❑Complies [FI411 cfm/100 ft2 across the system or ft' ft2 ❑Does Not <=3 dm/100 ft2 without air handler @ 25 Pa. For rough-in []Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F12711 determine air leakage with ft2 ft' ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F1912 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [F11112 systems have automatic or []Does Not accessible manual controls. ❑Not Observable []Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions & Re .ID I I Value Value Complies? Comments/Assumptions 403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ONot Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI2612 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑No[Observable temperature based on outdoor []Not Applicable temperature. _ 403.5.1.1 Heated water circulation systems ❑Complies (FI2812 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies (FI2912 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the []Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F13012 have recirculation pumps that ❑Does Not pump waterfrom a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI3112 tested in accordance with CSA []Does Not 855.1.Potable water-side pressure loss of drain water heat EJ Not Observable recovery units< 3 psi for []Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. _ 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent []Does Not fixtures have high efficacy lamps. Does not apply to low-voltage []Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI2313 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 9 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions 401.3 Compliance certificate posted. ❑Complies [F17]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 1 Low Impact(tier 3) Project Title:The Kimball Report date: 07/17/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\92 Burnt Hills Drive.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments aril 10, 2003 January 4, 2014 sen & Steves 2014, Plat C-349 al / f U �� a U U- 66, \ 9 68 os5 �� b N v u� 3g) 3 , N � Z S ��a 0 ~ LOT 5 -- -- 54290.8 Sq. Feet 1.25 Acres i U i V r N 82°12'48" c SFz � C13 o M Ct y 443,27 ,17, 1111 m o= � N 84°14 '31" W M o v �— D - m 10 r _ Co c c r m o m o � 308.8-1-74 RC-000463-2017 o " �'o y = Michaels Group Homes LLC 92 Burnt Hills Dr., Lot 5 m rn SFD 1939 s.f., Garage 493 s.f. Map Reference: Map Of Proposed Subdivision Made For Laric Development, LLC Dated:April 10, 2003 Last Revised:January 4, 2014 By: Van Dusen&Steves LOT 4 Filed:March 3, 2014, Plat C-349 s S c 38 66,01?1 N •sS km T 0 J 0 Z 1000 GAL. D15TRI13UTION BOX SEPTIC TANK LOT 5 ea 54290.8 r Sq. Feet A1350RPTION 1.251 Acres TRENCHES 3 @ 50 EA. �A. I If If If 48 N 82 121 If 127.71 Sto ,y / W •-��`c'3•'�' �r,:=;:,<°fix tz ra N 06045'42" W 15. 14 A, R = 375.00 W 443.27 +i L = 100.30 Ch = 100.06 N 84014131, W n S 13025' 138 W Q I 1 - THIC LAS ' CSR, E LOT 6 In ?I827•1 r SEPTIC SYSTEM - AS BUILT BY NACE ENGINEERING D Date:: December U5, '2011 A u 'UNAUTHORIZCDCENSE LN 5LIRVVOR55ASURVEI' M Survey JcQIy 1"��O' MAP BEARING AUCENSED LAND SUNflOR55EPL 15A Map of a Sul fey made for VIOLATION OF SCCTION 7209.5LIB-DIVISION 2.Or THE NEW YORK STATE EDUCATION IAW.' S ONLY MTH A FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVETDRS SCALL SHALL BE CONSIDERED TO BE VALID TRUE COPIC5.' '((\��l 'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT Gregory �./ • Potter THIS 5UKVCY WAS PREPARED IN ACCORDANCE WITH THE CASTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED Land Survey ors LANDSURVEYYOORS SAIDCC CA�PROFESSIONAL � To THE PERSON FOR WHOM THE 5LNRVEY 15 PREPARED,AND ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL 169 Haviland Road Queensbury, New York 12804 TO�GNEC5LENDINFT1 a�°�TL« 'A"° Town of Queensbury, Warren County, New York 1 1215117 SEPTIC AS BUILT POTTER (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 99-241-LOT 5