Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-000010-2017
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000010-2017 Date Issued: Friday, February 9, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000010-2017 has been completed. Tax Map Number: 289.10-1-31 Location: 9 HEMLOCK RD Owner: Holly Dansbury, Michael Dansbury Applicant: McAvinney Builders LLC This structure may be occupied as a: Single Family Dwelling: Alteration 303 s.f.; Addition 48 s.f. By Order of Town Board Attached Garage 754 s.£ TOWN OF QUEENSBURY Porch 111 s.f. Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. } TOWN OF QUEENSBURY ti 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 I Community Development- Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000010-2017 Tax Map No: 289.10-1-31 Permission is hereby granted to: McAvinney Builders LLC For property located at: 9 HEMLOCK RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Holly Dansbury Single Family-Alteration $100,000.00 Owner Address: PO Box 278 Total Value $100,000.00 Bolton Landing,NY 12814 Contractor or Builder's Name/Address Electrical Inspection Agency McAvinney Builders LLC 83 Carefree LN Lake George,NY 12845 Plans&Specifications Single Family Dwelling: Alteration 303 s.f.;Addition 48 s.f. Attached Garage 754 s.f. Porch 111 s.f. Permit fee paid on invoice 1381 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,February 1,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the ex 'ration date.) Dated at the Town o ueensb �We e e ruary 1,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office Use Onl Received 20 1 Date: Tax Map ID Tax Map ID c) o - - 2j� Permit No. ` ����-� ; Zone �2If 1 b", _. Rec.:ft!t n 1 Historic Site Yes No Site P1 # rl Subdi s # Subdivision Name A' © # Project Location I_m 1_6L_ FIN� � M . TOWN BD. RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family,apartments, condominiums,townhouses, and/or manufactured& modular homes, but not mobile homes. This is in addition to the permit fee(s). ApplicantN\Aq, kjfJEj t-�1,1i u o c Owner 604A -Z -'Act-1 N tiJ'&'(, Address e s � Address pt)AoxI 7y (50(_(zC'f*J)1"� Phone/E-mail ka,�y13 Phone/E-mail PAv'�akq 0LM& WPAA,'�6a. 6) 6V4, 1L i(OM Contact Person for Building&Codes Compliance: L-(,/L D�J S Phone ts� S10/ TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1St floor sf 21d floor sf Total sf Height Single Family Two-Family Multi-Family (# of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage 7 / (1, 2, 3, 4+) 5 g� 71�"I]J Other rti mllIil ILI If commercial or industrial please indicate of business Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 I If commercial or industrial please indicate name of business Proposed use of building or addition rl.,4A l'xu_ Source of Heat(circle one) Gas iI Propane Solar Other Fireplace: Complete a separate application for Fuel Burning It-opL!60 TO gn-4&V Appliances & Chimneys Are there structures not shown on plot plan? �.lp Are there easements on the property? do Site Information: a. Dimensions or acreage of lot 'q'vty b. Is this a corner lot? Yes _No c. Will the grade be changed as a result of construction Yes _X No d. Public water or Private well (circle one) Public Private e. Sewer or Private Septic System(circle one) Sewer rivate Value of all work to be performed(labor or materials) $ f 0di 000 DECLARATION.- 1. ECLARATION.1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ay1 L A y i 1 i ki L1 DATE: /1) -filhi SIGNATURE: 7D 2 ( A DATE: tri J")01') For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 NATURAL LIGHT,VENTILATION AND EMERGENCY EGRESS CALCULATION SHEET Job Site Address: 41 w uaL z_ Date: I /01 / 11 Owner: Application No.: Habitable Rooms Area of Room-Sq.Ft. Required light Actual light—sq.ft. Required ventilation Actual Ventilation sq.ft. Sq.Ft.opening for 8%of room 4%of room egress rl Oel 154 10-11, tg.& 5.14& 1,$.g G.0 V2 = 12.0 W ky-,Pi-I U14TILrx To Pekv,,ILj pow � 1-z To F-r H NL ,f At., 2LJO FWF, t?mt-V3 To Pe - JO Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 s f Jw- 4 01 t 2X__-Ip_ : 4 S- S is a F 4. 444 (4)60i 504)(lievi Awk Vo .._�a��;'i..� ��...�lrw. ...._. �;����k.y..�.�t�I�+� :- .�1<►li-. ��i'±!R...il..� ��� �i_•_.� s� � �� .. r � .' _ __ _ , _ � __ �„, _, ,,�._ � � �;:�,.�� .� . � o�,.�.�l�► • _�M Baa . ��,� - _. --204646 (T2 r r 90-0 E iu r 289.10-1-31 RC-000010-2017 Dansbury, Michael & Holly 9 Hemlock Road Residential Add. 48 s.f.,Alt. 303 s.f., Garage 754 s.f., Porch 111 s.f. .. .. 6 a4 Ar - . N _ terms- etc ;_ ► . E tt � .. . Tw... MAO. 0 • • leol N� n ..._ a REScheck Software Version 4.5.2 Compliance Certificate Project Dansbury Residencea E C E 0 W E Energy Code: 2015 IECC Location: Warren County, New York +r Construction Type: Single-family Project Type: Addition TOWN OF QUBENSBURY Climate Zone: 6 (8499 HDD) I BUILDING& CODES Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 9 Hemlock Road Michael& Holly Dansbury Curtis Dybas Town of Queensbury, NY 12804 PO Box 278 19 Deer Run Bolton Landing, NY 12814 Lake George, NY 12845 518 321 1870 518 668 5591 hdansbury@gmail.com cdybas@yahoo.com Compliance: 0.0%Better Than Code Maximum UA: 17 Your UA: 17 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. s Ceiling 1: Flat Ceiling or Scissor Truss 52 38.0 0.0 0.030 2 Wall 1: Solid Concrete or Masonry:Interior Insulation 143 13.0 7.8 0.051 7 Window 1: Wood Frame:Double Pane with Low-E 10 0.300 3 Wall 2: Wood Frame, 16" o.c. 17 21.0 0.0 0.057 1 Basement Wall 1: Solid Concrete or Masonry 80 0.0 15.0 0.051 4 Wall height: 4.0' Depth below grade: 3.6' Insulation depth: 4.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in t REScheck Inspection Checklist. c' , Q �G ' 2..1O Name'-T le Signature Date 289.10-1-31 RC-000010-2017 Dansbury, Michael & Holly 9 Hemlock Road Residential Add. 48 s.f., Alt. 303 s.f., Garage 754 s.f., Porch 111 s.f. Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitied.rck Page 1 of 9 REScheck Software Version 4.6.2 Inspection Checklist Energy Cade: 2015 iECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # I Pre-inspection/Plan Review I Value Value Complies? Comments/Assumptions &Req ID i I I I 103.1, Construction drawings and ❑Complies 4 103.2 documentation demonstrate ❑does Not [PR1]1 energy code compliance for the building envelope.Thermal []Not Observable envelope represented on []Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 1103.2, documentation demonstrate ❑Does Not 1403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable j Systems serving multiple []Not Applicable I dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per RCCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: []Not Observable Manual J or other methods approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: i 1 1High Impact(Tier 1) i 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitled.rck Page 2 of 9 section Plans Verified I Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO411 insulation R-value.Where interior R- R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable Ii required in warm-humid locations I in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not U. manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values, distance from top of wall. i�: ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO1112 to protect exposed exterior ❑Does Not t insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitied.rck Page 3 of 9 Section Plans Verified Field Verified & Re ID Framing/Rough-In Inspection Value i Value Complies? I Comments/Assumptions q' --- — -- 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 t-, 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSR 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. _ 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate :52.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is []Does Not V >= 3 inches in diameter and >= ❑Not Observable R-6 where < 3 inches.Supply and return ducts in other portions of []Not Applicable the building insulated >=R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not fr ❑Not Observable []Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not U. below 55 QF are insulated to >_R- ❑ 3 Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not _ ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 (High Impact(Tier 1) 2 Medium Impact(Tier 2) 1 3 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitled.rck Page 4 of 9 1 IHigh Impact(Tier 1) 2 1 Medium Impact(Ter 2) 3 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitled.rck Page 5 of 9 Section Plans Verified ! Field Verified # I Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not y provided. ❑Not Observable []Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]' exterior,the exterior insulation requirement applies(FR10). ❑ Steel E] Steel ❑Not Applicable 11 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) ( 2 (Medium Impact(Tier 2) 13 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitied.rck Page 6 of 9 Section Plans Verified ' Field Verified # Final Inspection Provisions ValueValue Complies. Comments/Assumptions & Re .ID ( ___J 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 6 (Fill' ❑Not Applicable FI1] 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every ❑ 300 ft2. Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122 12 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation aR-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 []Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. []Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F 19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [Fl 10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [Fill]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable i 1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitied.rck Page 7 of 9 Section Plans Verified Field Verified ! & Re q.ID' Final Inspection Provisions Value Value ! Complies? 1 Comments/Assumptions (- 1403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback []Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. _ 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically ❑Not Observable adjust the energy input to the heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. _ 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water ❑Not Observable supply pipe back to the heated water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies [F[31]2 tested in accordance with CSA ❑Does Not 855.1. Potable water-side ❑Not Observable pressure loss of drain water heat ❑Not Applicable recovery units< 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. ❑Not Observable Does not apply to low-voltage ❑Not Applicable lighting. 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable F'11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 1 3 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitled.rck Page 8 of 9 Section Plans Verified i Field Verified & R q,lp Final Inspection Provisions —Value i_ Value ! Complies? — Comments/Assumptions 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 ;High Impact(Tier 1) _L2 LMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Dansbury Residence Report date: 01/09/17 Data filename: C:\Users\Curtis\Documents\Dansbury\Untitied.rck Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wail 20.80 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating : Window 0.30 Door CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments