Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-000023-2017
TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000023-2017 Date Issued: Friday, January 25, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-000023-2017 Tax Map Number: Location: Owner: 289.9-1-40 42 SULLIVAN PL Mark Dickinson DTD Drafting LLCApplicant: This structure may be occupied as a: SFD Addition 672 s.f. (Master Bedroom) Cross Ref.Area Variance Z-AV-2-2017 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000023-2017 Tax Map No: 289.9-1-40 Permission is hereby granted to: Mark Dickinson For property located at: 42 SULLIVAN PL In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvoe of Construction Owner Name: Mark Dickinson Single Family-Addition $30,000.00 Owner Address: 42 Sullivan PL Total Value $30,000.00 Lake George,NY 12845 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications SFD Addition 672 s.f. (Master Bedroom) Cross Ref.Area Variance Z-AV-2-2017 $134.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,February 16,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Thursday,February 16,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement A PRINCIPAL STRUCTURE APPLICATION Office Use Only Received Date: 1 13oZ Tax Map ID —T Permit No. '�–0?� Tax Map ID Z$9. c?9 ' / " `f Permit Fee 1 .40 Zone Ree-Fee 1•�,� c s_ ?moi ,C l�k Z3 Historic Site Yes X No Site Plan# Subdivision Name Lot# Subdivision# Project Location Y2_ J�the/-kej jDlaC-,e_ TOWN BD. RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family,apartments,condominiums,townhouses, and/or manufactured&modular homes, but not mobile homes. This is in addition to the permit fee(s). Applicant Owner M �1 C k ✓t , Address Address Y2- s� ��a', ©l. to ke Geo f N tIS�1S Phone/E-mail Phone/E-mail _57 _ 7-16 3 7'6 9 Uvr 911 s ��tMa�I, w�►-� Contact Person for Building&Codes Compliance: A ti 1y Phone' 776-7yq TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 13'floor sf 2"d floor sf Total sf Height Single Family Y � �7 Z 2 / " r Two-Family Multi-Family ; (#of unitsri L r � _ DU .i �e Townhouse TOWN OF QUEEN SBURY Business Office Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) Other If commercial or industrial please indicate of business Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 INSPECTION WORKSHEET (000578-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal RC-000023-2017Permit Case Number:Case Module: Fri Jan 25, 2019Passed Inspection Date:Inspection Status: John O'BrienResidential Final Inspection Inspector:Inspection Type: 42 SULLIVAN PL289.9-1-40 Job Address:Parcel Number: Lake George, NY 12845 Contact TypeCompany NameName Granted PermissionDickinson, Mark ArchitectDTD Drafting LLC Primary OwnerDickinson, Mark EngineerDL Dickinson Associates ApplicantDTD Drafting LLC Checklist ItemPassedComments General CommentsYES11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors. - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R (West Signs have them they are on Dix Avenue) Jan 25, 2019Page (1) INSPECTION WORKSHEET (000578-2019) Checklist ItemPassedComments - Site Inspection by Bruce Frank. 1/25/19 Final Inspection Approved - Ok to issue CO! Site Plan / Variance requiredYES OK to Issue C/OYES11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors.q - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R ( West Signs has them they are on Dix Avenue) - Site Inspection by Bruce Frank. 1/9/19 Final Inspection Partial Approval - Site Inspection by Bruce Frank. 1/25/19 Final Inspection Approved - Ok to issue CO! O'Brien, John (Inspector) Jan 25, 2019Page (2) Proposed use of building or addition Re5t4t—Y4;-,J IW4 st' -Ped,� Source of Heat (circle one) Gas Oil Propane Solar ther Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? A)Q Are there easements on the property? No Site Information a. Dimensions or acreage of lot Q • '�f acG. b. Is this a corner lot? M J c. Will the grade be changed as a result of construction Yes _� No d. Public water or Private well e.�Sewer or Private Septic System Value of all work to be performed (labor or materials) $ 70 dc) DECLARATION.- 1. ECLARATION:1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application,plans and supporting materials are a true and complete statement/description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: I rc I Af Joj DATE: SIGNATU DATE: i ?a For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised September 2015 INSPECTION WORKSHEET (007857-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000023-2017Case Module:Permit Inspection Date:11/13/2018Inspection Status:Failed Inspector:John O'BrienInspection Type:Residential Final Inspection Job Address:42 SULLIVAN PLParcel Number:289.9-1-40 Lake George, NY 12845 Contact TypeCompany NameName Granted PermissionDickinson, Mark Primary OwnerDickinson, Mark EngineerDL Dickinson Associates\[DL Dickinson Associates\] , ArchitectDTD Drafting LLC\[DTD Drafting LLC\] , ApplicantDTD Drafting LLC\[DTD Drafting LLC\] , Checklist ItemPassedComments General CommentsYES11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors. - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R (West Signs have them they are on Dix Avenue) - Site Inspection by Bruce Frank. 4 inch Building Number Address visible from roadYES Chimney Height / B Vent / Direct Vent LocationYES Chimney Rain Cap InstalledYES Fresh Air IntakeYES Fresh air supply 3' from gradeYES 3" Plumbing Vent through roof minimum 18 inchYES Roof Complete / Exterior Finish CompleteYES Platform at all exterior doorsYES Handrail 4 or more risersNO Guards at stairs,decks,patios 30" + above gradeNO Nov 13, 2018Page (1) INSPECTION WORKSHEET (007857-2018) Checklist ItemPassedComments Guard at stairwell at 34" or moreNO Window guards req:<2' above floor/6' above grade -YES quick release installed Guard at deck, porches 36" or moreYES Handrail Termination at Newell Post or WallNO Interior/Exterior Railings 34 to 38NO Wood deck: 2'+ from grade dia bracing required - H/CNO ramp compliant 4+ Deck Joist Ledger Connections-24" From EndsNO Deck Ledger-Bolted per CodeNO Grade away from foundation 6 with 10 feetYES 6 clearance to sill plateYES HVAC Vent Terminal 10' from Lot Line & OpeningsYES Interior privacy/trim/doors/main entrance 36YES Bathroom / Kitchen WatertightYES Low flow toilet 1.3 gal/flushing cycle -YES showerhead/faucet Safety glazing: w/in 5' of tub/shower - stairwell win/adj toYES drs Smoke Detectors: Carbon MonoxideNO Smoke Detectors 3' from Kitchens & Baths R314NO Every level, Every bedroomNO Outside every bedroom areaNO Inter ConnectedNO Battery backup: _____NO Bathroom Fans, if no windowYES Plumbing fixturesYES Foundation insulation to floorYES Energy Sticker on Elec. Panel:R-Val. & Heating SysNO Duct work sealed properlyYES Intake OpeningsYES Nov 13, 2018Page (2) INSPECTION WORKSHEET (007857-2018) Checklist ItemPassedComments HRV or ERV Installed per Bedroom RequirementsYES Emergency egress below gradeYES Furnace shut-off w/in 30 ft. or w/in line of siteYES Furnace Hot Water Heater operatingYES Relief Valve ,Heat Trap/Water Temp 110 deg or lessYES Basement stairs closed rise greater than 4 inchesYES Fin Elect; Energy Saving Light Bulbs 50 PercentYES Arc Fault Breaker Habitable SpacesYES Site Plan / Variance requiredNO Truss ID Signage Installed at Electrical MeterNO OK to Issue Temporary C/ONO OK to Issue C/ONO11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors. - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R ( West Signs has them they are on Dix Avenue) - Site Inspection by Bruce Frank. O'Brien, John (Inspector) Nov 13, 2018Page (3) INSPECTION WORKSHEET (000141-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal RC-000023-2017Permit Case Number:Case Module: Wed Jan 9, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienResidential Final Inspection Inspector:Inspection Type: 42 SULLIVAN PL289.9-1-40 Job Address:Parcel Number: Lake George, NY 12845 Contact TypeCompany NameName Primary OwnerDickinson, Mark EngineerDL Dickinson Associates ApplicantDTD Drafting LLC ArchitectDTD Drafting LLC Granted PermissionDickinson, Mark Checklist ItemPassedComments General CommentsYES11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors. - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R (West Signs have them they are on Dix Avenue) Jan 09, 2019Page (1) INSPECTION WORKSHEET (000141-2019) Checklist ItemPassedComments - Site Inspection by Bruce Frank. Site Plan / Variance requiredNO OK to Issue C/ONO11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors.q - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R ( West Signs has them they are on Dix Avenue) - Site Inspection by Bruce Frank. 1/9/19 Final Inspection Partial Approval - Site Inspection by Bruce Frank. O'Brien, John (Inspector) Jan 09, 2019Page (2) INSPECTION WORKSHEET (007857-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000023-2017Case Module:Permit Inspection Date:11/13/2018Inspection Status:Failed Inspector:John O'BrienInspection Type:Residential Final Inspection Job Address:42 SULLIVAN PLParcel Number:289.9-1-40 Lake George, NY 12845 Contact TypeCompany NameName Granted PermissionDickinson, Mark Primary OwnerDickinson, Mark EngineerDL Dickinson Associates\[DL Dickinson Associates\] , ArchitectDTD Drafting LLC\[DTD Drafting LLC\] , ApplicantDTD Drafting LLC\[DTD Drafting LLC\] , Checklist ItemPassedComments General CommentsYES11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors. - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R (West Signs have them they are on Dix Avenue) - Site Inspection by Bruce Frank. 4 inch Building Number Address visible from roadYES Chimney Height / B Vent / Direct Vent LocationYES Chimney Rain Cap InstalledYES Fresh Air IntakeYES Fresh air supply 3' from gradeYES 3" Plumbing Vent through roof minimum 18 inchYES Roof Complete / Exterior Finish CompleteYES Platform at all exterior doorsYES Handrail 4 or more risersNO Guards at stairs,decks,patios 30" + above gradeNO Nov 13, 2018Page (1) INSPECTION WORKSHEET (007857-2018) Checklist ItemPassedComments Guard at stairwell at 34" or moreNO Window guards req:<2' above floor/6' above grade -YES quick release installed Guard at deck, porches 36" or moreYES Handrail Termination at Newell Post or WallNO Interior/Exterior Railings 34 to 38NO Wood deck: 2'+ from grade dia bracing required - H/CNO ramp compliant 4+ Deck Joist Ledger Connections-24" From EndsNO Deck Ledger-Bolted per CodeNO Grade away from foundation 6 with 10 feetYES 6 clearance to sill plateYES HVAC Vent Terminal 10' from Lot Line & OpeningsYES Interior privacy/trim/doors/main entrance 36YES Bathroom / Kitchen WatertightYES Low flow toilet 1.3 gal/flushing cycle -YES showerhead/faucet Safety glazing: w/in 5' of tub/shower - stairwell win/adj toYES drs Smoke Detectors: Carbon MonoxideNO Smoke Detectors 3' from Kitchens & Baths R314NO Every level, Every bedroomNO Outside every bedroom areaNO Inter ConnectedNO Battery backup: _____NO Bathroom Fans, if no windowYES Plumbing fixturesYES Foundation insulation to floorYES Energy Sticker on Elec. Panel:R-Val. & Heating SysNO Duct work sealed properlyYES Intake OpeningsYES Nov 13, 2018Page (2) INSPECTION WORKSHEET (007857-2018) Checklist ItemPassedComments HRV or ERV Installed per Bedroom RequirementsYES Emergency egress below gradeYES Furnace shut-off w/in 30 ft. or w/in line of siteYES Furnace Hot Water Heater operatingYES Relief Valve ,Heat Trap/Water Temp 110 deg or lessYES Basement stairs closed rise greater than 4 inchesYES Fin Elect; Energy Saving Light Bulbs 50 PercentYES Arc Fault Breaker Habitable SpacesYES Site Plan / Variance requiredNO Truss ID Signage Installed at Electrical MeterNO OK to Issue Temporary C/ONO OK to Issue C/ONO11/13/18 Preliminary Final Inspection Not Approved Remaining Items: - Install guard rails and handrails on deck steps as discussed. See attached details. - Install closed risers on deck steps. - Remove tripping hazard at top of deck steps as discussed - Need to test new smoke detectors and co detectors. - Install deck tension ties as discussed in 4 locations. Refer to attached detail. - Install additional 2 x 10 deck header at end support. See attached detail. At each post attach an additional pressure treated 2 x 4 from under beams to top of piers for additional bearing. - Add diagonal 2 x 4 bracing at ends only as discussed. 24" down on post and 24" out on beam. - Install handrail on egress stairs from basement as discussed. - Install Truss ID Sticker at electrical meter pan. V/R ( West Signs has them they are on Dix Avenue) - Site Inspection by Bruce Frank. O'Brien, John (Inspector) Nov 13, 2018Page (3) REScheck Software Version 4.6.3 Compliance Certificate M E FILE COPY o m Project Mark Dickinson Energy Code: 2015 IECC Location: Glens Falls, New York U Construction Type: Single-family (y Project Type: Addition $ r; d Q +,� : `� " Orientation: Unspecified O � � -Fu Zone: 6 (7635 HDD) N > Permit Date: TOWN OF QUEENSBURY C Permit Number: BUILDING&CODES v •� 00 04 N Construction Site: Owner/Agent: Designer/Contractor: CV d Queensbury, NY 12804 Mark Dickinson DTD Drafting, LLC 265 Aviation Rd. Queensbury, NY 12804 518-339-7451 —ompliance: Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum UA: 90 Your UA: 90 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Ceiling 1: Flat Ceiling or Scissor Truss 672 49.0 0.0 0.026 17 Wall 1: Wood Frame, 16" o.c. 534 24.0 0.0 0.054 25 Orientation: Unspecified Window 1: Wood Frame:Double Pane with Low-E 30 0.300 9 Orientation: Unspecified Door 1: Glass 36 0.300 11 Orientation: Unspecified Basement Wall 1: Solid Concrete or Masonry 608 21.0 0.0 0.046 28 Orientation: Unspecified Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. — I_ --_: ,, //. h6 Name-Title -5 ature Date Project Title: Mark Dickinson Report date: 11/09/16 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 1 of 1 2015 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 24.00 Below-Grade Wall 21.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments REScheck Software Version 4.6.3 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Reci.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. --__-__ _-------_.-._-- --___-� _ _--_- 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 289.9-1-40 RC-000023-2017 Dickinson, Mark & Melissa 42 Sullivan Place REVISED PLANS FEB 13 2017 TOWN! OF QOJIF..C'}l;:t;,J R y BUILDi11T & f 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact (Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 1 of 8 section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.1D 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope assemblies [FO4]1 insulation R-value. Where interior R_ R_ ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. [-]Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. _ ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not 41, insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 'High Impact(Tier 1) 2 IMedium Impact(Tier 2) i 3 1 Low Impact(Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 2 of 8 Section Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 Ll-factors of fenestration products ❑Complies [FR4]1 are determined in accordance []Does Not 14 with the NFRC test procedure or taken from the default table. []Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. [-]Not Observable ❑Not Applicable ----------- -_--- - - -----__._...__—.------ 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not V, AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not V >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and [-]Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not U, ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to >R- [-]Not Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR 19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 12 IMedium Impact(Tier 2) 3 1 Low Impact(Tier 3) j Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 3 of 8 11 High Impact (Tier 1) 12 IMedium Impact(Tier 2) i 3 Low Impact(Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 4 of 8 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID� 7 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not t� provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN311 exterior,the exterior insulation requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: (l High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 5 of 8 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. [:]Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of []Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Fl9]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. ❑Not Applicable - 403.1.2 Heat pump thermostat installed ❑Complies [Fl 1012 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [F]11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 jMedium Impact (Tier 2) 3 iLow Impact (Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 6 of 8 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Reci.ID 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. --- -------__-___---- 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. - ----- - - --- --— - - ------------ 403.5.1.2 --- -----403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403 5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. _ 404.1 75%of lamps in permanent ❑Complies [1716]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123 13 no continuous pilot light. ❑Does Not *, [-]Not Observable ❑Nat Applicable 11 High Impact (Tier 1) 12 IMedium Impact(Tier 2) 13 ILow Impact(Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 7 of 8 i � a Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: i 1�High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Mark Dickinson Report date: 02/11/17 Data filename: C:\Users\Devin\Documents\REScheck\Dickinson-Mark.rck Page 8 of 8 THERK4 Am Qua :ty Corrfort, Satisfaction. Thermal Associates 21 Thomson Ave.Glens Falls, NY 128oi 5i8.798.55oo Fax 798.5620 Mark Dickinson 42 Sullivan Place Lake George, NY 12845 518-796-7769 We, Thermal Associates, inspected the property at 42 Sullivan Place, Lake George, NY, to determine he feasability of performing a blower door test, for Mark Dickinson on April 25, 2017. We determined that in rder to perform the test, the homeowner would have to incur undue costs associated with repeat frivolous rips for multiple subcontractors. Therefore, we recommend visual inspections with attention to proper aulking and sealing of each penetration of the perimeter of the addition. lh 1102.4.3.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less an seven air changes per hour(ACH)when tested with a blower door at a ressure of 33.5 psf(50 Pa)as verified using instruments and procedures specified in ASHRAE/ASTM E779.The test shall be conducted by a ualified person,who shall demonstrate competence to the satisfaction of the code nforcement official for the conduct of such tests. For the purpose of this section,ACH50 shall mean air changes per hour of infiltration into a ouse as measured with a blower door at 50 pascals of pressure,in accordance with SHR-AE/ASTM E779.Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations or utilities,plumbing,electrical,ventilation and combustion appliances. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed; .Dampers shall be closed,but not sealed,including exhaust,intake, makeup air,back draft and flue dampers; 3. Interior doors shall be open; 4. Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling system(s)shall be turned off, 6. HVAC ducts shall not be sealed;and 7. Supply and return registers shall not be sealed. Adam DeVit Blower Door Tester Thermal Associates www.thermalassociates.com _ I U cw N W 0"'T ELEVATION N O Z iCID CD CL 0Q O C/) NORTH ELEVATIONsmoke detector omsgand oa- (1) LQ n B ch floor M M Q adjacent t® be cellar or basement. a 0 level including O All smoke detectors,nnnecled w h ® � detectors shall be baCKUP and located on all Igvels. 0� ._ '� Q buttery aired _` �``: '``'''.`'•'��` nd on all Levels. c') v y yt`F � O ., ,, monoxide detectors are req 00 1, , bbl•.y, i'`y�;� .,t car "oping dress a O Q N Lu \1 e<1i1�4��ti �� N PROPOSED ADDITION ,,� ^_ ... - W,.... ._... _..._ . ... ......... .. .. 5 ; ti t 1 Qry OI �} 00 v7 Cn NOTICE 1 _ " « U -7.7 _ _. _:..:_.m m-_V':M:mc:::.::_.....::.......�-.:'.m.:..:..:_—..--•�-r.-::..__«:a:.:...:.:.:.:.�..-.:-.:::.�-.c:c.:m:-..'_-._""''=-rr..':::z-._.,_._....._...,_.::.-�...�_,z: COVERED INSULATION YEA MINUTE FOAM 7L:] 3 ...._.._ ,,,.__... THERMAL BARRIER fff .. i ............... .......... . .. EE - �iiis ::;;'; neo'/%;;•%`c'f�` _- .,i I - - - '4. _ g _ 'QU� OJ " ,t is�=•. . .�, ., . . y # a'•a;_JS'i"t.-}'- � 'M}I ...,t_, f- .f'' 1s a "() 10 I ;p ---- U Q' U 110 _ s j I o z .� 0 O tn _ - 1 TOWN OF QUEENSB URY SOUTHELEVATIU E BUILDING DEPARTMENT Cl- C) Q QBased on our limited examination,compliance With our comments shall not be construed as indicating the plans and sppecifications are in i full compilance with the Buildin. Codes I of New York State. M���m � 2.,WS }r��'`•,,.mI y.>�' '� ,1 ''.��5 - Ca'4F ,Psi PROPOSED ADDITION PSItp, REVISED 1 i I _ .................................................__.._....................... ....................„....«.-......._. ..__......................_...._,,................,.................. 0 .................... .......... ................. ................................ ........... ...... ............... _. —.------ ...- _._ _ C/)_................. I -...-,. ._. ....._..... .................,..............,.,. --].... " .. ... ....._........_ _.,.. ...........•...«...,._.«.,,......__.....” _........ ........_._-..._, 21,E I _ ;3 Fy L _ 1 l?_'slt`:}i hews e' et A i Elevation ° 0 — o LEESh bet ° Existine, First Floor PlanT z5 eet A3 : Proposed First Floor and Addition Sheet A4: 7 Foundation/Cross p X �Q a� a� - I . 1-4— E C v EO o 0 FEB 13 21117 0 ,Q) b�j YLU Cj— rat11LDlinr &�;Ot3 1