Loading...
RC-000507-2017 "Oltimk TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building&Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000507-2017 Date Issued: Thursday, September 20, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000507-2017 has been completed. Tax Map Number: 226.15-1-13 Location: 120 LAKE PKWY Owner: Richard Chase Applicant: Adirondack Designers&Builders This structure may be occupied as a: Single Family Dwelling w2 FPs 2796 s.f. Garage 506 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, (074 j 4 Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000507-2017 Tax Map No: 226.15-1-13 Permission is hereby granted to: Adirondack Designers&Builders For property located at: 120 LAKE PKWY In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvne of Construction Owner Name: Richard Chase Single Family-New $700,000.00 Owner Address: 41 Glenmere DR Total Value $700,000.00 Chatham,NJ 07928 Contractor or Builder's Name/Address Electrical Inspection Agency Adirondack Designers&Builders PO Box 181 Lake George,NY 12845 Plans&Specifications Single Family Dwelling w2 FPs 2796 s.f. Garage 506 s.f. $735.10 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,September 12,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town ofues y S e 12,2017 W SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only Permit#: PRINCIPLE STRUCTURE PERMIT Permit Fee:$ APPLICATION ..•.� 1 tJ Town of Quccnsbur *Rec Fee:$ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Invoice#: 21 Project Location: 1'20 Tax Map ID#: �'Z C�.. I I _ 13 Subdivision Name: I ��'I� 'P��►�T `TOWN BD.RESOLUTION 86-2013: $850 recreation f n f mily,duplexes/two-family, multiple family, apartments, condominiums,townhouseo1 homes, but not mobile homes. This Is In addition to the permit fee(s). AUG 18 2017 CONTACT INFORMATION: TOWN OF QUEENSBURY • Applicant: 13U LDING&CODES Name(s): 1�►�l�aD C�tiIF—��LLt I���llr� I"IA Elxl`� �J Mailing Address, C/S/Z: 12•a- 06 X- 12v6iE�� e6lc til--r- 12~3 Cell Phone: Land Line: ( 5I0 ) Lo '76 � Email: • Primary Owner(s): Name(s): I-icAA.2t: V. Mailing Address, C/S/Z: 4I LaI�_t-INtE12+= D�i�/� , C-�-��T °�•� y��� ' Cell Phone: ( ")'73 ) 721 7 Land Line: Email: • Contractor(s): / A Business Name: Contact Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: Email: • Architect(s)/Engineer(s): Business Name: l�T7Ir?or,��/aC-Iti "1 =Si �.1>=QS �Ut1+7��'-� Contact Name(s): Mailing Address, C/S/Z: (�516) &qq 10 S 7q5 -0307 Cell Phone: _� ) Land Line: Email: �'— Contact Person for Building& Code Compliance: F`����►-� t �` `= ��'� Cell Phone: ( 5 I ) 3 U! J'2-3 `E Land Line: Email: X171) V 1 ►_l l3i�t 1-0 @`6p-�uQ 60 t-A Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 PROJECT INFORMATION: / TYPE: Commercial ✓ Residential WORK CLASS: Zsingle-Family _Two-Family Multi-Family(#of ) Townhouse Business Office _Retail —Hotel/Motel Industrial/Warehouse Garage(#of cars ) _ -Other(describe ) STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 11T floor: ►g 11T floor: 60L o /r" 2nd floor: 2nd floor: Q 3rd floor:_ Total square feet: d�o 4th floor: ►�-l�J� Total square feet: ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 1700, cY o 2. Proposed use of the building: � ►,-tG1x rAMI�- ��r7��►�C� 3. If Commercial or Industrial, indicate the name of the business: ��A 4. Source of Heat (circle one): Gas Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances &Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES NO?,txplain: 6. Are there any easements on the property? YES 7. SITE INFORMATION: l a. What is the dimensions or acreage of the parcel? 01 35 A (�, `a5 b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the constru YES (OD d. What is the water source? PUBLIC _ PRIG V— A E WELL (LA-�S e. Is the parcel on SEWER or a RIVATE SEPTIC system., -2' IL Toavr.o`Queensbury Suk"&Code Enforcement Pnnciple Structure App!"t:�n Revised February 2' DECLARATION: 1. 1 acknowledge that no construction shall commence prior to issuance of a valid b u i I ding permit and work will be completed within a 12 month period. 2. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. ;. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed 1, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: 45,111 VA-t�jsV-1 k SIGNATURE: �� `J��- DATE: Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury, NY 12804 Town af(t. ury p: 518-761-8256 www.gueensbury.net Permit#: Tax Map ID#: 226.15-1-13 Permit Fee: $ ; Invoice#: Project Location: 120 Lake Parkway I Septic Variance? Yes No Primary Owner(s) Richard D.Chase Mailing Address 41 Glenmere Dr.Chatham,NJ 07928 Phone & Email rchase@soluslp.com Installer/Builder Rick McGuire/Kevin Maschewski(builder) Mailing Address P.O.Box 181,Lake George,NY 12845 Phone & Email (518)361-1255/adkdesignbuild@yahoo.com-Kevin Engineer Hutchins Engineering Mailing Address 169 Haviland Road,Queensbury NY 12804 Phone & Email (518)745-0307/thutchins@hutchinsengineering.com Contact Person for Building&Code Compliance: Hutchins Engineering or K.Maschewski phone: 745-0307/361-1255 RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes No 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes ©o Installed? (circle one) 1992-Present 4 110 440 PARCEL INFORMATION: Topography ✓ Flat Rolling Steep Slope %Slope Soil Nature Sand _ /�Loam Clay Other Groundwater At what depth? 30" Bedrock/Impervious material At what depth? >44" Domestic Water Supply _Municipal _Well (if well, water supply from any septic system absorption is 110 ft.) Percolation Test Rate: 16-20 per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: t Devi Tank size 1 1250 gallons(min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with #2 stone Total length ft.; Each Trench ft. Seepage Pit with #3 stone How many: ; Size: Alternative System Bed or other type: PRESBYAES-108 LF Holding Tank System Total required capacity? ; tank size ;#of tanks NOTES: 1. Alarm system &associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: Kevin Maschewski builder DATE: 8/17/2017 SIGNATURE: • Town of Queensbury Buiing&Code Enforcement Revised February 2017 - FUEL BURNING APPLIANCE & office use only CHIMNEY APPLICATION Permit#: IL-' Permit Fee:$ i0W11 ul(,uern>hun" " Invoice:#: 742 Bay Road,Queensbury, NY 12804 P:518-761-8256 www.gueensbury.net Project Location: LAW5 KAIZ "V � y Tax Map ID#: 226- 11A3 - I -k. > Room of Install: -VI�J4 '620 M Planned Install Date: V..1-I L_A EI° '2C?w **ONE APPLICATION PER APPLI IRZ 0 WJE AUG 18 2017 CONTACT INFORMATION: TOWN OF QUEENSBURY BUILDING R CODES • Applicant: I Name(s): /�D�R�L—�r�At�, 1���1C�a1 � l —2 .TSL-- (geVj-! Mailing Address, C/S/Z: ��oo �aK lel L � EoF , ►—L` "fd I'LL Cell Phone: ( 51F'-) ei,1 -I 2�55 Land Line: ( �5 Email: • Primary Owner(s): Name(s): "01&"OD 12- (fi-i ;- Mailing Address, C/S/Z: q1 C?l Ei AMEV—E T70vFA aA.7r4A4A c2rl">28 Cell Phone:_(�`13 ) '727 -- ©1 7 Land Line: _{ ) Email: • Installer/Builder: _ Business Name: �P n � 1 r '�r-E � �UvE /AVi1?0),L " "l�r��►-�E�� r-z1-f% Contact Name(s): ► Mailing Address, C/S/Z: (�� Q • 1�1 1-A-�'E � D � ►�� Y` I �`/ Cell Phone: Land Line: _(slti ) L, Y ' �Q 3 Email: Contact Person for Building & Code Compliance: Cell Phone: ).&o/ - 255 Land Line: _(slg Email: Fuel Burning Appliance&Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: —Stove _Fireplace Insert _Fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) ZFireplace,factory built** **Manufacturer's name: 4�T +_..<� to Model#: �► SOURCE OF HEAT: / _Wood _Coal _Pellet V Gas CHIMNEY INFORMATION: _Ma nry: block _brick _stone ✓Flue: ,/te _tie _✓sel t/size, in inches �A� �q�. 13� Nl�`+–��C= T�I► ✓Material*: -� —double-wall —triple-wall insulated (*Manufacturer's name: kA-T�A 6 Model#: "Jo'T ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces &chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. Declaration:Construction/installation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: 1IJ 1`rF� I SIGNATURE: DATE: "18, WIrl Fuel Burning Appliance&Chimney Application Revised March 2017 • - FUEL BURNING APPLIANCE & office use only CHIMNEY APPLICATION Permit#: e e— —504 '201 -- Permit Fee:$ Invoice:#: 742 Bay Road,Queensbury, NY 12804 P:518-761-8256 www.gueensbury•net Project Location: J;20 Lj�,V�5 VAa�V—Lhy Tax Map ID Room of Install: roo 12 654 -� 1I„Planned Install Date: �Ll-I►-1 **ONE APPLICATION PER AUG 18 2017 CONTACT INFORMATION: TOWN Y N D NG&ODES B • Applicant: Name(s): lt7� t-1L7 -� 1"7i✓Sl��i.l � 1tD�-i2-� T'C� (Y�E.i��J /(,4s r-_v�t��`, , Mailing Address, C/S/Z:=I �� 3c� >L Ill L e F-0 IL6 Cell Phone: _) `� �� "1 Land Line: Email: • Primary Owner(s): Name(s): �ic;t-�f2� �, '-E=_ Mailing Address, C/S/Z: y 1 C� I N«� `�F, L;T< T4AJA 26 Cell Phone:_(x'73 ) 17 2`7 - C>17Y Land Line: _( ) Email: • Installer/Builder: Business Name: � /�1—u'� Ylr'� 71f JJ�vvE / f7it�i71�G� lei ' ►- �i Contact Name(s): /h►'Yi►•1A�G,1�E ��`' i Mailing Address, C/S/Z: Cell Phone:_( I�' ) 3 �12�5 Land Line: Email: Contact Person for Building & Code Compliance: Cell Phone: (6I1?, ) Stn/ 12 5 Land Line: Email: Fuel Burning Appliance&Chimney Application Revised March 2017 r FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: / Stove _Fireplace Insert V Fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) _Fireplace, factory built** **Manufacturer's name: Model#: IDT dJi-r—L45�--TES> SOZwood RCE OF HEAT: _Coal _ Pellet _Gas CHIMNEY INFORMATION: M�nry: block brick stone V Flue: _tie ✓steel —size, in inches�P.-'� �? '�° i tq&v.1 U Fri-TLi 12C) y"Material*: ✓double-wall _triple-wall=insulated (*Manufacturer's name: ,GA-T (off Model #: iJc) Ji t=Tw7 ) ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces &chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. Declaration:Construction/installation must conform to NYS Fire Prevention &Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: SIGNATURE: DATE: Ind - ^ Y Fuel Burning Appliance&Chimney Application Revised March 2017 Tf If Devin T. 0—k! t. fE 5 1 -G68 4G74 5URVEYOR5-- ENGINEER-5- LAND CON5ULTANT5 30 5tor e 5choolf`ou5e Roael P.Q. Sox 356 Lake George: New York 2645 FILE COPY 5 September 2017 Mr. John O'Brien i Town of Queensbury Building Code Bay Road } SEP 0 Queensbury, New York 12804 TOWN 0-,i= t RE: Chase Residence Wind Loading ? ` � ;`i✓ Dear Mr. O'Brien: The following is a summary of the adjusted wind load that has been used to analyze the structural members, as proposed on plans by Adirondack Designers & Builders. Residential Wind Load for Exposure D (R301.2.1.4) Wind Speed = 115 mph Mean Roof Height= 25'± Adjustment Coefficient= 1.61 (Table R301.2(3)) Roof Pitch = 27 to 45° Effective Wind Area = 20 sf Wind Load = 12.7 psf(Table R301.2(2)) Adjusted Wind Load = 12.7 x 1.61 = 20.45 psf Note: Adjusted wind load applied to each structural member during load analysis. If you have any questions or would like to discuss this further, please do not hesitate to contact my office. Sincerely, Dennis L. Dickinson, PE dtd Manual S Compliance Report Job. 17-9998-228 wrightsofts p p Date: Sep 06,2017 Entire House By: BJ Kozlowski B&B Plumbing and Heating 18 Division St Suite 401,Saratoga Springs,NY 12866 Phone:518-584-4440 Fax:518-584-0496 Email:bj@bbphsaratoga.com Web:www.bbphsaratoga.com Project • • For: Chase Res,ADK design FILE C O P 120 Lake Parkway, Queensbury, NY Y Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 42500 Btuh Entering coil DB: 72.0°F Outdoor design WB: 70.8°F Latent gain: 2154 Btuh Entering coil WB: 60.0°F Indoor design DB: 72.0°F Total gain: 44654 Btuh Indoor RH: 50% Estimated airflow: 1850 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: YCE60B21+CF/CM/CU60C+TM9V100Cl6MP11+TXV Actual airflow: 1850 cfm Sensible capacity: 38850 Btuh 91%of load Latent capacity: 16650 Btuh 773%of load Total capacity: 55500 Btuh 1240% of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 80811 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Prop furnace Manufacturer: York Model: TG9S100C16MP11 Actual airflow: 1850 cfm Output capacity: 97000 Btuh 120%of load Temp. rise: 50 OF �j SEP 01 201, E; Meets are all requirements of ACCA Manual S. TOWN, .` wrl htsoft 2017-Sep-06 15: ge 1 �� 9 Right-Suite®Universal 2017 17.0.17 RSU19952 Page 1 ..\bj\Documents\Wrightsoft HVAC\ADK Chase res.rup Calc=MJ8 Front Door faces: W 9 e DHW Report Job: 17-9998-228 wri htsoft Date: Sep 06,2017 Entire House By: BJ Kozlowski B&B Plumbing and Heating 18 Division St Suite 401,Saratoga Springs,NY 12866 Phone:518-584-4440 Fax:518-584-0496 Email:bj@bbphsaratoga.com Web:www.bbphsaratoga.com Project • • For: Chase Res,ADK design 120 Lake Parkway, Queensbury, NY Design Occupants Not occupied during the day Age Number Dishwasher 0-5 0 Clothes washer 6-13 2 Additional use(gpd) 0 14-59 2 Setpoint(°F) 120 60+ 0 Daily use (gpd) 61 Propane • • 41 gal, 0.60 Manufacturer Tank size(gal) 40 Trade name Energy factor 0.60 Model Input(MBtuh) 0.0 AHRI ref. number 1st hour(gal) 60 Recovery eff. (%) 77 Wrl htsoft® 2017-Sep-0615:44:38 9 Right-Suite®Universal 2017 17.0.17 RSU19952 Page 1 A+CK ...\bj\Documents\Wrightsoft HVAC\ADK Chase res.rup Calc=MJ8 Front Door faces: W rm Form �.. Residential • PIPER 1 ,4C(1K for HVAC System Design •. • • • 15 Mar 09 ArC corvacsrsdknOlM Queensbury Header Information Contractor: B&B Plumbing and Heating REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes Ej No ❑ Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes EJ No ❑ Building plan#: Manual D Friction Rate Worksheet: Yes ❑ No ❑ Duct distribution sketch: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): 120 Lake Parkway, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 IF Orientation: Front Door faces West Indoor temperature: 70 IF North,East,west,south,Northeast,Northwest,Southeast,southwest Total heat loss: 80811 Btuh Number of bedrooms: 0 Conditioned floor area: 3151 ft2 Summer Design Conditions Number of occupants: 4 Outdoor temperature: 85 IF Indoor temperature: 72 IF Windows Roof Grains difference: 33 gr/Ib @50% RH Eave overhang depth: 0,5 ft g Sensible heat ain: 47222 Btuh Internal shade: none "a Latent heat gain: 2393 Btuh Blinds,drapes,etc. Depth Window Total heat gain: 49616 Btuh Number of skylights: 0 EQUIPMENTHVAC • 41 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Prop furnace Equipment type: Split AC Heating cfm: 1850 Furnace,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc. Cooling cfm: 1850 Model: York Model: York Static pressure: 0,10 in H2O TG9S100C16MP11 YCE60621 Fan's rated external static pressure for design airflow Heating output capacity:. 97000 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 1850 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0.10 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0.10 in H2O Friction rate: in/100ft Branch duct: Sheet metal Friction Rate=ASP-(TEL x 100 I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verif ication. Contractor's printed name: Contractor's signature: Date: Reserved for County,TownMunicipality `Home qualifies for MJ1 AE Form based on Abridged Edition Checklist + wrightsoft° Right-Suite®Universal 2017 17.0.17 RSU19952 Load Short Form Job: 17-9998-228 wrightsofta Date: Sep 06,2017 Entire House By: BJ Kozlowski B&B Plumbing and Heating 18 Division St Suite 401,Saratoga Springs,NY 12866 Phone:518-584-4440 Fax:518-584-0496 Email:bj@bbphsaratoga.com Web:www.bbphsaratoga.com Project Information For: Chase Res,ADK design 120 Lake Parkway, Queensbury, NY Design Information Htg Clg Infiltration Outside db(°F) -4 85 Method Simplified Inside db(°F) 70 72 Construction quality Semi-tight Design TD (°F) 74 13 Fireplaces 2(Semi-tight) Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/Ib) 52 33 HEATING EQUIPMENT COOLING EQUIPMENT Make York Make York Trade YORK Trade YORK Model TG9S100C16MP11 Cond YCE60621 AHRI ref 2008574 Coil CF/CM/CU60C+TM9V100C16MP11+TXV AHRI ref 8440355 Efficiency 95.5AFUE Efficiency 11.8 EER, 14 SEER Heating input 100000 Btuh Sensible cooling 38850 Btuh Heating output 97000 Btuh Latent cooling 16650 Btuh Temperature rise 48 OF Total cooling 55500 Btuh Actual air flow 1850 cfm Actual air flow 1850 cfm Air flow factor 0.023 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.10 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.95 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Room6 781 15319 4341 351 189 Room8 111 6447 4120 148 179 Room9 349 7104 0 163 0 Room12 1911 51940 34039 1189 1482 Entire House d 3151 80811 42500 1850 1850 Other equip loads 0 0 Equip. @ 0.90 RSM 38250 Latent cooling 2154 TOTALS 3151 80811 40404 1 1850 1 1850 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoftW 2017-Sep-0615:44:38 9 Right-Suite®Universal 2017 17.0.17 RSU19952 Page 1 ..\bj\Documents\Wrightsoft HVAC\ADK Chase res.rup Calc=MJ8 Front Door faces: W Project Summar Job: 17-9998-228 ro + - wrightsoft- Y Date: Sep 06,2017 Entire House By: BJ Kozlowski B&B Plumbing and Heating 18 Division St Suite 401,Saratoga Springs,NY 12866 Phone:518-584-4440 Fax:518-584-0496 Email:bj@bbphsaratoga.com Web:www.bbphsaratoga.com Project • • For: Chase Res,ADK design 120 Lake Parkway, Queensbury, NY Notes: Design Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 IF Outside db 85 OF Inside db 70 IF Inside db 72 IF Design TD 74 OF Design TD 13 OF Daily range M Relative humidity 50 % Moisture difference 33 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 80811 Btuh Structure 42500 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 80811 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 38250 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 2(Semi-tight) Structure 2154 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 3159 2802 Equipment latent load 2154 Btuh Volume (W) 30711 24438 Air changes/hour 0.29 0.15 Equipment total load 40404 Btuh Equiv.AVF (cfm) 148 61 Req. total capacity at 0.70 SHR 4.6 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade YORK Model TG9S100C16MP11 Cond YCE60621 AHRI ref 2008574 Coil CF/CM/CU60C+TM9V100C16MP11+TXV AHRI ref 8440355 Efficiency 95.5 AFUE Efficiency 11.8 EER, 14 SEER Heating input 100000 Btuh Sensible cooling 38850 Btuh Heating output 97000 Btuh Latent cooling 16650 Btuh Temperature rise 48 IF Total cooling 55500 Btuh Actual air flow 1850 cfm Actual air flow 1850 cfm Air flow factor 0.023 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.10 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.95 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I FttSOft" 2017-Sep-0615:44:38 WI 9 Right-Suite(g)Universal 2017 17.0.17 RSU19952 Page 1 ...\bj\Documents\W rights oft HVAC\ADK Chase res.rup Calc=MA Front Door faces: W N Level 2 Room6 1850 cfm ®351 cfm L] RooL:O179 cfm Job #: 17-9998-228 B&B Plumbing and Heating Scale: 1 : 97 Performed by BJ Kozlowski for: Page 1 Chase Res 18 Division St Suite 401 Right-Suite®Universal 2017 120 Lake Parkway Saratoga Springs.NY 12866 17.0.17 RSU19952 Queensbury, NY Phone:518-584-4440 Fax:518-584-04962017-Sep-0615:44:51 www.bbphsaratoga.com bj@bbphsaratoga.com ..ghtsoft HVAC\ADK Chase res.rup N Level 1 Room9 ® 163 cfm Room12 ® 1482 cfm Job #: 17-9998-228 B&B Plumbing and Heating Scale: 1 : 97 Performed by BJ Kozlowski for: Page 2 Chase Res 18 Division St Suite 401 Right-Suite@ Universal 2017 120 Lake Parkway Saratoga Springs,NY 12866 17.0.17 RSU19952 Queensbury,NY Phone:518-584-4440 Fax:518-584-0496rightsof2 H A�DK Chase res.rup www.bbphsaratoga.com bj@bbphsaratoga.com UNITARYPRDU GROUP INSTALLATION GUIDE Horizontalseries HRV MODEL S1-HRV160 and MODEL S1-HRV220 E-1311 RAGOE-1 151 NOW 60 anti RICIBR-Al FRV9*A 3 o �s � # INSTALLATION GUIDE 18. Specification and Technical Information Easy Access Door SPECIFICATIONSf removable top hinge door Size 237/8"x 21111"x 113/e" 237""x 2112"x 161,'2" Heat exchanger(L x H x W) 12"x 12"x 10" 12"x 12"x 15" CFM 30 to 160 50 to 220 Type of heat exchanger cross-flow cross-flow Exchange surface 104 ft? 150 ft Power consumption 130 W 150 W im RL Defrost type Exhaust Exhaust Certification HVI,CCSAUS HVI,CCSAUS SPECIFICATIONS 1 1 Size 23Te"x 21111"x 113'8" 2371e"x 211/2"x 161/1" Heat exchanger(L x H x W) 12"x 12"x 10" 12"x 12"x 15" CFM 30 to 160 50 to 220 Type of heat exchanger cross-flow cross-flow Exchange surface 104 ft 150 ft SI-HRV160 113,0 j 23Power consumption 130 W 150 W S-H RV220 161/x" Defrost type SI-ERV160 111/8" Exhaust Exhaust SI-ERV220 161-2" Certification CCSA,, CCSA,, Note to installer All Unitary Products Group products are backed by the best limited warranty on the market. Unitary Products Group reserves the right to modify aproduct,without prior notice,whether in design,color or specifications,in order to offer at all times a quality product that is highly competitive. Certified Products and Proud Member of These Associations Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. C'CS0 U S AWALNEW CERTIFIED 19 � r Compliance Certificate is F=COPY Project Chase Residence N 0 Energy Code: 2015 IECC ti LO Location: Lake George, New York — — - Construction Type: Single-family DIE C (5 0 V(�� Lr(� O U, Project Type: New Construction LO Orientation: Unspecified V � Conditioned Floor Area: 2,801 ft2 6 AUG 18 2017 Glazing Area 23% CD Climate zone: 6 (7377 HDD) -QUEENSBURY 12r1_TOWN Permit Date: BUILDING&CODES i N Permit Number: L N r V LL Construction Site: Owner/Agent: Designer/Contractor: W NCV 120 Lake Parkway Richard D. Chase Kevin Maschewski N 3 Queensbury, NY 41 Glenmere Drive Adirondack Designers& Builders, J Chatham, NJ 07928 Inc. N .0 N PO Box 181 LL Lake George, NY 12845 N V U) Compliance: 1.1%Better Than Code Maximum UA: 460 Your UA: 455 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Ceiling 1: Flat Ceiling or Scissor Truss 703 49.0 0.0 0.026 18 Ceiling 2: Cathedral Ceiling 1,170 49.0 0.0 0.022 26 North Wall Elev.: Wood Frame, 16" o.c. 599 24.5 0.0 0.053 28 Orientation: Unspecified Window#11: Wood Frame:Double Pane with Low-E 16 0.300 5 Orientation: Unspecified Window#12:Wood Frame:Double Pane with Low-E 13 0.300 4 Orientation: Unspecified Window#17: Wood Frame:Double Pane with Low-E 15 0.300 5 Orientation: Unspecified Patio Door#10: Glass 21 0.300 6 Orientation: Unspecified South Wall Elev.: Wood Frame, 16" o.c. 561 24.5 0.0 0.053 26 Orientation: Unspecified Window#5: Wood Frame:Double Pane with Low-E 25 0.300 8 Orientation: Unspecified Window#6: Wood Frame:Double Pane with Low-E 42 0.300 13 Orientation: Unspecified Window# 14: Wood Frame:Double Pane with Low-E 11 0.300 3 Orientation: Unspecified 722 24.5 0.0 0.053 20 Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 1 of 10 Window#7: Wood Frame:Double Pane with Low-E 105 0.300 32 Orientation: Unspecified Window#8: Wood Frame:Double Pane with Low-E 64 0.300 19 Orientation: Unspecified Window#15:Wood Frame:Double Pane with Low-E 9 0.300 3 Orientation: Unspecified Window#16: Wood Frame:Double Pane with Low-E 64 0.300 19 Orientation: Unspecified Patio Door#9: Glass 96 0.300 29 Orientation: Unspecified East Wall Elev.: Wood Frame, 16" o.c. 589 24.5 0.0 0.053 24 Orientation: Unspecified Window#2: Wood Frame:Double Pane with Low-E 13 0.300 4 Orientation: Unspecified Window# 3: Wood Frame:Double Pane with Low-E 35 0.300 11 Orientation: Unspecified Window#13: Wood Frame:Double Pane with Low-E 32 0.300 10 Orientation: Unspecified Entry Door#1: Solid 48 0.050 2 Orientation: Unspecified Floor 1: Slab-On-Grade:Heated 204 10.0 0.684 140 Insulation depth: 6.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requirement listed i the RE ck Inspection Checklist. to�T Name-Title S gna re Date Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 2 of 10 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review ( Plans Verified Field Verified Complies? Comments/Assumptions &Req.ID _ Value Value 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 3 of 10 Section ! Plans Verified Field Verified & Re ID Foundation Inspection Value Value i Complies? Comments/Assumptions q.ID — 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values. ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [FO3]1 depth/length. ❑Does Not table for values. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 i High Impact(Tier 1) 2 Medium Impact(Ti( r 2) 3 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 4 of 10 Section on Framing/Rough-In Inspection plans Verified Field Verified Complies? Comments/Assumptions & Req.ID Value Value 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. _ 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55 QF are insulated to>_R- ❑ 3 Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 5 of 10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) =Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 6 of 10 Section # Insulation Inspection Plans Verified Field Verified Complies? Comments/Assumptions & Req.ID Value Value ---i ---- 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). El steel E] Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not []Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 7 of 10 Section I IPlans Verified Field Verified Co # I Final Inspection Provisions— — mplies? Comments/Assumptions� & Req.ID � Value Value 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.6 ❑ Steel ❑ Steel ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable _ ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable ❑Not Applicable 402.4.2 Wood-burning fireplaces have ❑Complies [F18]2 tight fitting flue dampers and ❑Does Not outdoor air for combustion. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F19]2 installed for control of primary []Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable j 1 High Impact(Tier 1)—1-2 1Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 8 of 10 Section Plans Verified Field Verified # i Final Inspection Provisions & Req.ID Value Value ( Complies? Comments/Assumptions , 403.5.1 Circulating service hot water ❑ComP lies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable []Not Applicable 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable _ temperature. _ 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 9 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? iC� omments/Assumptions & Req.ID 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. '❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: gh Impact(Tier 1) 12 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Chase Residence Report date: 08/10/17 Data filename: C:\Users\Kevin2\Documents\REScheck\Chase Residence.rck Page 10 of 10 Ji' :ws M f1 Above-Grade Wall 24.50 Below-Grade Wall 0.00 Floor 10.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Window 0.30 Door 0.30 Heating System: Cooling System: Water Heater: Name: Date: Comments 11.7- -Alm R 71 cs -A "A 4x A M Zvi- I n-L k�!� V P1 13 �gz, ---- Tralo 110 "Al.WIll M,I _k SNOtV t �­­��X_ zl!vt� 71F, IT X5 5tt. nz S.;-V�NS-, g .41 "V 101 m 'N� Tr g I 411�l QP tZK_,X_**r-;4..# M eX-, INN '4�0 _04 kt �w7k knmi� Ny!, N",R1, It, '071, Ell -vi T% 1!I'm�A, -V A j- 6A A,"i I-4*140 F xk,*4M 'N-M S� 5 0 4P -gc gj�4 mill 'rill Z# R - I�,Z '4 j'k U_x �g W Fw LOO" 20" AW 1b k.^ .ill's 47� Tf �M_ v", vv-. cp-iy, 4. A qlga: `0 gq Nr 2: 4­1 L0$" 23 W, V1 U Y�W-4 dir ro I 0 4*rO I.P.F. k� K. FL 01 Am, 'It N4 1�WT., .01.1 LO:Arwv 24 0.1175� LOCATION MAP L and is n/f of Arthur A. & Alison V. Bl'amey Book 590 Page f197 4:� 10 21± *01, BOA 7' 110USP Q) /0 1§l 5tg' A, rN CK 22.4' Sle, LOT 25 % , IS NORTHERLY AREA 102"± ALONG 0.35± ACRES 8- I.P. z THE SHORE AS IT WINDS & TURNS 0) 0 r"r e. tic field 50.0" sep 4V porc h CO IX sto Q e v 57.1' X xx 21± 0 Q, air conditioner C3 21.1 48. ear DE ED il.?EFERENCE.- Ul underground propone 0 1) WILLIAM R. CORNELL TO AM BETH LYNNE CORNELL rain I.R.F. W FILED IN THE OFFICE OF THE WARREN COUNTY guttj CLERK IN BOOK 1460 AT PAGE 202 LOT 26 /.- of L ands n/ r _M_A_P REFERENCE: 'r _j Kara. Ham-11'en 1) "MAI OF FIRST SUB—DIVISION OF PROPERTY OWNED BY THE Book 3195 Page 5u LAKI__ GEORGE ASSEMBLY AT ASSEMBLY—POIN T—ON—LAKE—GEORGE DA"FE-1) JUNE 8t 1914 PREPARED BY ERNEST L H. MEYERS, SURVEYOR. _N_O-TES* 1) BASE MAP PREPARED FROM AN AUGUST 2018 FIELD SURVEY. 2) NORTH ORIENTATION IS BASED ON MAGNETI.0 NORTH 2007. I N L NAN",jO'm' U y 3) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OF TITLE AND IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS OR RESTRICTIONS OF RECORD ANY STATEMENT OF FACTS SUCH DOCUMENT WOULD DISCLOSE. fL 1C.Oft r+% 2)Q�t e"�- 4) UNAUTHORIZED ALTERATION OR ADD111ON TO A SURVEY MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, LOT 27 SUBDIVISION 2, OF THE NEW YORK STATE EDUCATION LAW. LEGEND 5) ONLY' COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS SEAL SHALL BE CONSIDERED TO 0 IRF IRON ROD FOUND BE VAUD TRUE COPIES. o IPF IRON PIPE FOUND 0 IRS IRON ROD SET CQJk UTJUTY POI F (DCXDCD STONE WALL x WIRE FENCE 0 CHAIN LINK FENCE c3 WOOD FENCE 0 POINT F.P. FENCE POST ohw— OVERHEAD WIRES n/f NOW OR FORMERLY IRRIGATION CONTROL VALVE 15" SEPTIC MANHOLE 0 UNDERGROUND El ECTRIC PVC VENT PIPE SEP 0 5 2018 w. oil 0V%jN OF QUEENSBURY r &CODES MADE FOR BUILDN" MAP OF A SURVEY 4: N'lli -- !�z�Aoklllir RICHARD CHA 00"E t _4 16 1 --vill, 4.1 GRAPHIC SCALE V,�- i 0I.- U 30 0 15 30 60 120 iv, ------ Town of Q?wensbury County of Wajl:,*ren State o New Y IT,"MM"mm 1 f JJ 41l- Jim, 20-2 rrAn NO MISSE2L zo jaull I IN FEET MCENSED SURV"IJW I inch 30 ft. 342 Mctin Street, Hudson Falls, New York Y2839 Russell E. Howard, PLS K Y.S. L%*c. No. 50540 Date.- 08 -'-0118 /Z x Map #:226.15—i F ,Date Sealed.-4) Scale.- I inch 30 feet Revised: Drawing 0 70946 Tom Hutchins .57 From: Tom Hutchins <thutchins@hutchinsengineering.com> Sent: Monday, September 17, 2018 10:13 AM To: 'John O'Brien' Cc: 'Kate Deck'; 'Kevin Maschewski' Subject: CHase Septic Record Attachments: 291096-01 SEPTIC RECORD-.pdf John/Kate- Attached is our record drawing for the septic system at Chase Residence, 120 Lake Parkway. We will hand deliver paper copies later today. Contact me if you need anything else. Regards,Tom G. Thomas Hutchins, P.E. Hutchins Engineering 169 Haviland Road Queensbury, NY 12804 (518) 745-0307 AS BUILT IL' ta'l W, E 77i ni r--- I il H ,DirLI)i 1 SEP 17 2018 ILi 1 li 1