CC-000521-2017 TOWN OF QUEENSBURY
; ty ,
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development - Building& Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: CC-000521-2017 Date Issued: Tuesday, November 13, 2018
This is to certify that work requested to be done as shown by Permit Number CC-000521-2017
has been completed.
Tax Map Number: 297.18-1-1
Location: 462 RIDGE RD
Owner: Glendening Realty, LLC
Applicant: James Glendening
This structure may be occupied as a: Commercial Addition 507 sq. ft.
Adirondack Animal Hospital By Order of Town Board
Cross Ref P-SP-29-2017 TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the 4
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: CC-000521-2017
Tax Map No: 297.18-1-1
Permission is hereby granted to: Brodie Farr Contracting
For property located at: 462 RIDGE RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvne of Construction
Owner Name: Glendening Realty,LLC Business Office-Addition $200,000.00
Owner Address: 395 Ridge RD Total Value $200,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Brodie Farr Contracting
4 Stonehurst DR
Queensbury,NY 12804
Plans&Specifications
Commercial Addition 507 sq.ft.
Adirondack Animal Hospital
Cross Ref.P-SP-29-2017
$150.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,September 17,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the ex iration date.)
Dated at the Town o ueensb �Frid er 15,2017
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
. r
Office Use Only
�^o
ADDITION/ALTERATION PERMIT Permit#: —
��11OG
APPLICATION Permit Fee: $ SCS
Town of Queensbury 4 �`
742 Bay Road,Queensbury,NY 12804 Invoice#: c-71 `v
1
P:518-761-8256 www.gueensbury.net
Project Location: 46-z gda-d
Tax Map ID #: q7 /tf —1 —1 Subdivision Name:
CONTACT INFORMATION:
• Applicant: It
Name(s): tLol s e. 6&"11111A
Mailing Address, C/S/Z: erd
Cell Phone: 5 f� ) 060 °-7.60,-' Land Line ( ';-18 ) 713 --,o"T-7 7
Email: aandoL Cyoi
• Primary Owner(s):
Name(s): ;d4 LLC
Mailing Address, C/S/Z: 3015 ' 'Ad 12h)14
Cell Phone: Land Line: S/ ) 79.3- LIS--7
Email:
• Contractor(s):
Business Name: f3doji� 1:�t'/ & ✓ &AL-h"
Contact Name(s): 63ah-e /j-r
Mailing Address, C/S/Z: Jh"A -sF Dr. Daae OUlfill .Vy /21f04
Cell Phone: Land Line: ( 15/S ) 7457- 54:3f
Email:
• Arch itect(WEngineer(s):
Business Name: J1VZ_ Anh4ech owd PlmnzrSr }� C
Contact Name(s): aySQ'a t
Mailing Address, C/S/Z: /q'o &('e r ��&i5
Cell Phone: �5( ) *ZM) - c).30Z Land Line: ( SIS ) 793 - 0'78�,-
E m a i I: buys ooj C� jm z cr-e�k rl c f5. 4-em
Contact Person for Building & Code Compliance: 14-hc(r-e o pa-i—so t §
Cell Phone: -( 51& ) 7&0 -0302 Land Line: ( 47 ) 7f3 -r�75�1a
Email: se,<-7,�0 z_4ak,G;t
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
PROJECT INFORMATION:
TYPE: X Commercial Residential
WORK CLASS:
Single-Family _Two-Family Multi-Family (# of units )
Townhouse X Business Office Retail
Industrial/Warehouse _Garage (# of cars ) Other (describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: _5707 ;rncla'i.'°s G;"&zd walk"JI) 1st floor:
2"a floor: 211 floor:
3rd floor: 3rd floor:
41h floor: 411 floor:
Total square feet: �D� Total square feet:
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction: $ 004 400
2. If Commercial project, what is the proposed use: V&Ari✓! w Hawl&l
3. Source of Heat (circle one): Gas Oil Propane Solar Other
Fireplaces need a separate Fuel Burning Appliances & Chimney Application
4. Are there any structures not shown on the plot plan? YES NO Explain:
5. Are there any easements on the property? YES
6. SITE INFORMATION:
a. What is the dimensions or acreage of the parcel?
b. Is this a corner lot? YES NO
c. Will the grade be changed as a result of the construction? YES NO
d. What is the water source? PUBLI � PRIVATE WELL
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? & Se h6
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
DECLARATION:
1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: /
SIGNATURE: DATE: '�`� /
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
INSPECTION WORKSHEET (BINS-005573-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:
Inspection Date:
Inspector:
Case Module:
Inspection Status:
Inspection Type:
CC-000521-2017
08/02/2018
John O'Brien
Permit
Failed
Commercial Final Inspection
Job Address:Parcel Number:462 RIDGE RD
Queensbury, NY 12804
297.18-1-1
Contact Type Company Name Name
Granted Permission Farr Contracting [Farr Contracting] ,
Architect JMZ Architects [JMZ Architects] ,
Applicant Glendening, James
Primary Owner Glendening Realty, LLC [Glendening Realty, LLC]
Contractor Farr Contracting [Farr Contracting] ,
Checklist Item Passed Comments
Plumbing Vent Through Roof/Roof complete YES
Ext Finish /Grade Complete/6 in 10ft or Equivalent YES
Doors 36 inch wLever Hand Panic Hardware, if req YES
Exits At Grade Or Platform 36 (w) x 44 (l)YES
Floor Bathroom Watertight Other Floors Okay YES
Handicapped Bath/Parking Lot Signage YES -Handicapped Parking Space only 7 ft needs to be 8 ft.
Universal Symbol of Access displayed - on all H/C
signs
YES
Final Electrical / Flex Gas Piping Bonded YES
Site Plan Variance required NO - Complete Site Items and Submit Site Certification.
Bldg Num or Tenant Address on Bld or Drive YES
Engineer or Architect Approval YES - Submit Final Approval Letter from Architect/Engineer.
8/2/18 Received Final Approval Letter from
Architect/Engineer.
Aug 02, 2018 Page (3)
INSPECTION WORKSHEET (BINS-005573-2018)
Checklist Item Passed Comments
OK to Issue C/O NO 7/5/18 Final Inspection Not Approved
Remaining Items:
- Complete Site Items and Submit Site Certification.
- Complete Fire Marshal's Items.
- Handicapped Parking Space only 7 ft needs to be 8 ft
wide.
- Submit Final Approval Letter from Architect/Engineer.
7/26/18 Final Inspection Not Approved
- Complete Site Items and Submit Site Certification.
- Submit Final Approval Letter from Architect/Engineer.
8/2/18 Final Inspection Not Approved
Remaining Items:
- Complete Site Items and Submit Site Certification.
Aug 02, 2018 Page (4)
O'Brien, John (Inspector)
INSPECTION WORKSHEET (BINS-004806-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-000521-2017Case Module:Permit
Inspection Date:07/05/2018Inspection Status:Failed
Inspector:John O'BrienInspection Type:Commercial Final Inspection
Job Address:462 RIDGE RDParcel Number:297.18-1-1
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantGlendening, James
Primary OwnerGlendening Realty, LLC,
ContractorFarr Contracting,
Granted PermissionFarr Contracting,
ArchitectJMZ Architects,
Checklist ItemPassedComments
Plumbing Vent Through Roof/Roof completeYES
Ext Finish /Grade Complete/6 in 10ft or EquivalentYES
Doors 36 inch wLever Hand Panic Hardware, if reqYES
Exits At Grade Or Platform 36 (w) x 44 (l)YES
Floor Bathroom Watertight Other Floors OkayYES
Handicapped Bath/Parking Lot SignageNO-Handicapped Parking Space only 7 ft needs to be 8 ft.
Universal Symbol of Access displayed - on all H/CYES
signs
Final Electrical / Flex Gas Piping BondedYES
Site Plan Variance requiredNO
Bldg Num or Tenant Address on Bld or DriveNO
Engineer or Architect ApprovalNO- Submit Final Approval Letter from Architect/Engineer.
OK to Issue C/ONO7/5/18 Final Inspection Not Approved
Remaining Items:
- Complete Site Items and Submit Site Certification.
- Complete Fire Marshal's Items.
- Handicapped Parking Space only 7 ft needs to be 8 ft
wide.
- Submit Final Approval Letter from Architect/Engineer.
O'Brien, John (Inspector)
Jul 05, 2018Page (1)
e
s
COMcheck Software Version 4,3.5.2
Envelope Compliance Certificate
Project Information
Energy Code: 2015 IECC
Project Title: Adirondack Animal Hospital
Location: Glens Falls, New York
Climate Zone: 6a
Project Type: Addition
Vertical Glazing/Wall Area: 24%
Construction Site: Owner/Agent: Designer/Contractor:
462 Ridge Road
Queensbury, New York 12804
Building Area Floor Area
1-Office: Nonresidential 107
Envelope Assemblies
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor.)
Perimeter
Roof:Attic Roof,Wood Joists,[Bldg.Use 1 -Office] 100 49.0 0.0 0.021 0.021
Floor:Unheated Slab-On-Grade,Vertical 4 ft.,[Bldg,Use 1 -Office](c) 107 --- 6.0 0.528 0.540
NORTH
Ext.Wall:Wood-Framed,16in.o.c.,[Bldg.Use 1-Office] 96 21.0 6,0 0.043 0.051
Door:Other(U-Factor option),Perf.Specs.:Product ID Andersen AND- 21 -- --- 0.350 0.770
N-139,SHGC 0.19,[Bldg.Use 1 -Office](b)
SOUTH
Ext.Wail:Wood-Framed,16in.o.c.,[Bldg.Use 1 -Office] 96 21.0 6.0 0.043 0.051
Door:Other(U-Factor option),Perf.Specs.:Product ID Andersen AND- 21 -- --- 0.350 0.770
N-139,SHGC 0.19,[Bldg.Use 1 -Office](b)
WEST
Ext.Wall:Wood-Framed,16in.o.c.,[Bldg.Use 1-Office] 96 21.0 6.0 0.043 0.051
Window:Vinyl Frame:Fixed,Perf.Specs.:Product ID Andersen 100 7 --- --- 0.290 0.360
Series Picture,SHGC 0.29,[Bldg.Use 1 -Office](b)
Window:Vinyl Frame:Fixed,Perf.Specs.:Product ID Andersen 100 7 --- 0.290 0.360
Series Picture,SHGC 0.29,[Bldg.Use 1 -Office](b)
Window:Vinyl Frame:Fixed,Pert.Specs.:Product ID Andersen 100 12 --- — 0.290 0.360
Series Picture,SHGC 0.29,[Bldg.Use 1-Office](b)
(a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements.
(b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Project Title: Adirondack Animal Hospital Report date: 09/05/17
Data filename: Page 1 of 12
Envelbbe PASSES: Desian 7% better than ..
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application.The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.3.5.2 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist. ��
'?1,5117
,�c1,.SO1 i 'a
Name-Title Signature D e
Project Title: Adirondack Animal Hospital Report date: 09/05/17
Data filename: Page 2 of 12
Adirondack Animal Hospital
462 Ridge Rd
Queensbury, NY 12804
Facade Renovation and Addition
Structural Calculations For
Facade Renovation and Addition
Prepared By:
Schoder Rivers Associates
Evergreen Professional Park
453 Dixon Road, Ste. 7, Bldg. 3
Queensbury, NY 12804
Client:
JMZ Architects and Planners, P.C.
190 Glen Street
Glens Falls, NY 12801
�
P
Carl B. Schoder, Principal
NYSPE # 62971
TABLE OF CONTENTS
Project Parameters Pages 1 - 7
Wood Framing & Pier Design Pages 8 - 30
Wind & Seismic Design Pages 31 - 37
Check Existing, Adjacent Framing Pages 38 - 49
Truss Connection Design Page 50
v
lis?ITA rAL4-Aon
�L
Chi"
N 5 No = �C> plo- X157.
1N 9 'M\AJ �C�S. _ C F C z. �YZT 2-
At
lo -°t 5v
i
51� C-L'As5
l
Dosign Maps Detailed Report Page 1 of 6 �
Design Maps Detailed Report
ASCE 7-10 Standard (43.336170N, 73.63071°W)
Site Class D - "Stiff Soil", Risk Category I/I1/11I
Section 11.4.1 — Mapped Acceleration Parameters
Note: Ground motion values provided below are for the direction of maximum horizontal
spectral response acceleration. They have been converted from corresponding geometric
mean ground motions computed by the USGS'by applying factors of 1.1 (to obtain Ss) and
1.3 (to obtain S,). Maps in the 2010 ASCE-7 Standard are provided for Site Class B.
Adjustments for other Site Classes are made, as needed, in Section 11.4.3.
From Figure 2-1 Ell SS = 0.232 g
From Figure 22-2`3 S, = 0.081 g
Section 11.4.2 — Site Class
The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or
the default has classified the site as Site Class D, based on the site soil properties in
accordance with Chapter 20.
Table 20.3-1 Site Classification
Site Class v, N or SU
A. Hard Rock >5,000 ft/s N/A N/A
B. Rock 2,500 to 5,000 ft/s N/A N/A
C. Very dense soil and soft rock 1,200 to 2,500 ft/s >50 >2,000 psf
D. Stiff Soil 600 to 1,200 ft/s - 15 to 50 1,000 to 2,000 psf
E. Soft clay soil <600 ft/s <15 <1,000 psf
Any profile with more than 10 ft of soil having the characteristics:
• Plasticity index PI > 20,
• Moisture content w ;-> 40%, and
• Undralned shear strength s. < 500 psf
F. Soils requiring site response See Section 20.3.1
analysis in accordance with Section
21.1
For Sl: ift/s = 0.3048 m/s ilb/ft2 = 0.0479 kN/m2
https://earthquake.usgs.gov/cn l/desigmnaps/us/report.php?template=minimal&latitude=43.... 8/1/2017
Design Maps Detailed Report Page 2 of b
Section 11.4.3 - Site Coefficients and Risk-Targeted Maximum Considered Earthquake
(MCER) Spectral Response Acceleration Parameters
Table 11.4-1: Site Coefficient F.
Site Class Mapped MCE R Spectral Response Acceleration Parameter at Short Period
Ss :s 0.25 SS = 0.50 Ss = 0.75 Ss = 1.00 Ss z 1.25
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1,2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of Ss
For Site Class = D and S, = 0.232 9, F. = 1.600
Table 11.4-2: Site Coefficient F.
Site Class Mapped MCE R Spectral Response Acceleration Parameter at 1-s Period
S, 150.10 S, = 0.20 S, = 0.30 S, = 0.40 S, ?_ 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.7 1.6 1.5 1.4 1.3
D 2.4 2.0 1.8 1.6 1.5
E 3.5 3.2 2.8 2.4 2.4
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of S,
For Site Class = D and S, - 0.081 g, F.= 2.400
https://earthquake.usgs.gov/cnl/desigmnaps/us/report.php?template=minimal&latitude=43.... 8/1/2017
'Design Maps Detailed Report Page 3 of 6
Equation (11.4-1): SMS = F.Ss = 1.600 x 0.232 = 0.372 g
Equation (11.4-2): Sr„ = F.SI = 2.400 x 0.081 = 0.195 g
Section 11.4.4 — Design Spectral Acceleration Parameters
Equation (11.4-3): SDS = % SMS = 2/ x 0.372 = 0.248 g
Equation (11.4-4): SDI = % SMI = 2/3 x 0.195 = 0.130 g
Section 11.4.5 — Design Response Spectrum
From Figure 22-12 i33 TL = 6"seconds
Figure 11.4-1: Design Response Spectrum
T<Te:Ss=Sb6(OA 4OAT/TO)
T,%T%T,:S.=3m
tiw0.248 -
I
I
T>TL.Si=%Tc/7
N I I
t I
I I
I I
I I
I I
I t
I t
-I-----------
__" -
Sut"Qa30 --I , --�----
-----
I I 1 i
V
duo ' I t
Gl I I I
I I I
tl11 I I 1
t I I
I I I
I I ,
� I I
I I
I t 1
t ,
� I I
I t
TA•O.lo5 Ts-0524 1
Period.T(W)
https://earthquake.usgs.gov/cnl/designmaps/us/report.php?template=minimal&latitude=43.... 8/1/2017
Design Maps Detailed Report Page 4 of 6 r�
Section 11.4.6 — Risk-Targeted Maximum Considered Earthquake (MCER) Response
Spectrum
The MCE,Response Spectrum is determined by multiplying the design response spectrum above by
1.5.
I
I I
I
� I I
I I
I I
I I
I I
! I
� I i
� I f
! 1
---------- —_—_
I ! i
I I 1
il' I I f
't9 I i I
I 1 1
I 1 1
N I I i
I I 1
I I 1
I ! 1
I i t
I 1 t
1 I
I I f
I I f
I 1 i
i 1 1
Ts OZZ4 1AW
plerkA T(aft)
https:Hearthquake.usgs.gov/cn 1/desigmnaps/us/report.php?template=minimal&latitude=43.... 8/1/2017
°Design Maps Detailed Report Page 5 of 6 ;
Section 11.8.3 - Additional Geotechnical investigation Report Requirements for Seismic
Design Categories D through F
From Fjigure 22-714' PGA = 0.117
Equation (11.8-1): PGA,, = Fc,PGA = 1.566 x 0.117 = 0.183 g
Tabie 11.8-1: site Coefficient F,c,
Site Mapped MCE Geometric Mean Peak Ground Acceleration, PGA
Class
PGA <_ PGA = PGA = PGA = PGA >_
0.10 0.20 0.30 0.40 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C X1.2 1.2 1.1 1.0 1.0
D I 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of PGA
For Site Class = D and RGA= 0.117 g, lF"A= 1.566
Section 21.2.1.1 - Method 1 (from Chapter 21 - Site-Specific Ground Motion Procedures
for Seismic Design)
From Figure 22-17t" CRS = 0.909
From Figure 22-16's] CR, = 0.895
https://earthquake.usgs.gov/cnl/designmaps/us/report.php?template=minimal&tatitude=43.... 8/1/2017
Resign Maps Detailed Report Page 6 of 6
D�
Section 11.6 — Seismic Design Category
Table 11.6-1 Seismic Design Category Based on Short Period Response Acceleration Parameter
RISK CATEGORY
VALUE OF S,,
I or II III IV
Sos < 0.167g A A A
0.167g :5 Sos < 0.33g B B C
0.338 5 SDs < 0.50g C C D
0.50g 5 Sos D D D
For Risk Category = I and SDs= 0.246 g,Seismic Design Category= B
Table 11.6-2 Seismic Design Category Based on 1-S Period Response Acceleration Parameter
RISK CATEGORY
VALUE OF Sol
I or II III IV
SDI < 0.067g A A A
0.067g 5 SDI < 0.133g B B C
0.133g 5 SDI < 0.20g C C D
0.20g 5 SDI D D D
For Risk Category= I and Sc., = 0.130 g,Seismic Design Category= B
Note: When S, is greater than or equal to 0.75g, the Seismic Design Category is E for
buildings in Risk Categorles I, II, and III, and F for those in Risk Category IV, irrespective
of the above.
Seismic Design Category = "the more severe design category in accordance with
Table 11.6-1 or 11.6-2" = B
Note: See Section 11.6 for alternative approaches to calculating Seismic Design Category.
References
1. Figure 22-1:
https://earthquake.usgs.goy/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-i.pdf
2. Figure 22-2:
https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-2.pdf
3. Figure 22-12:
https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-12.pdf
4. Figure 22-7:
https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/201 D_ASCE-7_Figure_22-7.pdf
5. Figure 22-17:
https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/20IO_ASCE-7_Figure_22-17.pdf
6. Figure 22-18:
https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-18.pdf
https://earthquake.usgs.gov/cnl/designmaps/us/report.php?template=minimal&latitude=43.... 8/1/2017
f
LPR( .
5Lo L
Lu }
Ar
lz
jlD
tN
-� o�
GUA 1.
C
14
fa
(o �� IAc
XI,S
�!S of LOA(),. ti It'o
COMPANY PROJECT
WoodWorks' -�Q .
.
Aug. 1, 2017 14:34 Columnl
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Axial (Ecc. = 2.0011) 1200 The
Load2 Snow Axial (Ecc. = 2.0011) 2000 lbs
Self-weight Dead Axial 61 lbs
Lateral Reactions (lbs):
- 10'
� o
m �
0'
10'
Unfactored•
Dead 20 -20
Snow 33 -33
Factored:
R->L 53
Load comb #2
L->R 53
Load comb #2
Timber-soft, S-P-F, No.2, 6x6 (5-112"x5-1/2")
Support: Non-wood; Bearing length =column width
Total length: 10';
Pinned base; Load face =width(b); Ke x Lb: 1.0 x 10.0= 10.0 [ft]; Ke x Ld: 1.0 x 10.0= 10.0 [ft]; Lateral support: top =
Lb, bottom =Lb;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Anal sis/Desi n
Shear fv = 3 Fv' = 144 fv Fv' = 0.02
Bending(+) fb = 231 Fb' = 575 fb/Fb' = 0.40
Axial fc = 108 Fc' = 418 fc/Fc' = 0.26
Combined (axial + eccentric moment) q.15.4-2 = 0.57 .
Axial Bearing fc = 108 Fc* = 575 fc/Fc* = 0.19
Live Defl'n 0.05 = <L/999 0.67 = L/180 0.07
Total Defl'n 0.09 = <L/999 0.67 = L/180 0.14
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Columnl WoodWorks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL/CP CF Cfu Cr Cfrt Ci LC#
Fv' 125 1.15 1.00 1.00 - - - - 1.00 1.00 2
Fb'+ 500 1.15 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 2
Fc' 500 1.15 1.00 1.00 0.726 1.000 - - 1.00 1.00 2
E. 1.0 million 1.00 1.00 - - - - 1.00 1.00 2
Emin' 0.37 million 1.00 1.00 - - - - 1.00 1.00 2
Fc* Soo 1.15 1.00 1.00 - 1.000 - - 1.00 1.00 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 53, V design r 53 lbs
Bending(+) : LC #2 = D+S, M = 533 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
Axial LC #2 = D+S, P = 3261 The
Eq.15.4-2 LC #2 = D+S Fb'= 575
FcE= 639 Pxe/S=fc(6xe/d)= 231
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 76e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Design Notes:
1. WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Axial load eccentricity applied in direction of load face only. It is the designers responsibility to check for effect of
eccentricity in the other direction.
COMPANY PROJECT
WoodWorks®
O
Aug. 1,2017 17:07 Beam1
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full Area No 15.00 (16.0)* psf
Load2 Snow Full Area Yes 40.00 (16.0) * psf
Self-weight Dead Full UDL No 1 2.2 plf
*Tributary Width (in)
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
10'_0.5"
I
0' 1'-6" 8'
Unfactored:
Dead 130
Snow 260 171
Factored:
Total 390 255
Bearing:
F'theta 540 540
Capacity
Joist 70911 405
2A
Supports 586 U(,4� —'J 586
Anal/Des ` `� �j
Joist 0.55 (� V 0.63
Support 0.66 v 0.44
Load comb #2 ? #4
Length 0.50* 0.50*
Min req'd 0.50* i 0.50*
Cb 1.75 `' 1.00
Cb min 1.75
�� a 1.00
Cb support 1.25 1.25
Fcp sup 625 625
*Minimum bearing length setting used: 1/2"for end supports and 1/2"for interior supports
Lumber-soft, S-P-F, No.1/No.2, 2x8 (1-1/2"x7-114")
Supports:All-Timber-soft Beam, D.Fir-L No.2
Roof joist spaced at 16.0"c/c; Total length: 10'-0.5"; Pitch: 8/12;
Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help);
Woodworks® Sizer SOFTWARE FOR WOOD DESIGN
Beaml WoodWorksO Sizer 9.3 Page 2
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Anal sis/Desi n
Shear fv = 27 Fv' = 155 fv Fv' = 0.17
Bending(+) fb = 359 Fb' = 1389 fb/Fb' = 0.26
Bending(-) fb = 82 Fb' = 1361 fb/Fb' = 0.06
Deflection:
Interior Live 0.04 = <L/999 0.39 = L/240 0.11
Total 0.07 = <L/999 0.52 = L/180 0.14
Cantil. Live -0.03 = L/721 0.18 = L/120 0.17
Total -0.05 = L/439 0.24 = L/90 0.20
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 4
Fb' - 875 1.15 1.00 1.00 0.980 1.200 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4
CRITICAL LOAD COMBINATIONS:
Shear : LC 42 = D+S, V = 228, V design = 193 lbs
Bending(+) : LC #4 = D+S (pattern: sS) , M = 393 lbs-ft
Bending(-) : LC #2 = D+S, M = 90 lbs-ft
Deflection: LC #4 = (live)
LC #4 = (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LCIS are listed in the Analysis output
Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 67e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Bearing: Allowable bearing at an angle F'theta calculated for each support
as per NDS 3 .10.3
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the
middle 2/3 of 2 span beams and to the full length of cantilevers and other spans.
4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1_
5. SLOPED BEAMS: level bearing is required for all sloped beams.
COMPANY PROJECT
WoodWo r ks® �o
SOlfN'.u[iOINKrOn tfFSKH ��/1 y
Aug. 1, 2017 17:03 Beaml
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full UDL 86.0 plf
Lcad2 Snow Full UDL 190.0 plf
Self-weight Dead lFull UDL I 1 10.6 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in)
13'-2.9"
I
0, 13'-2"
Unfactored:
Dead 639 639
1258
Snow 1258
Factored:
Total 1896 1896
Bearing:
Capacity 1896
Beam 1896
Supports 2979 2979
Anal/Des
Beam 1.00 1.00
Support 0.64 0.64
Load comb #2 #2
0.81
Length 0.81
Min req'd 0.81 0.81
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 i.07
625
Fcp sup 625
X
S-P-f� NoA 6x10 (5-112"x9-1/2")
Timber-soft,
Supports:A -T11mber- Beam, D.Fir-L No.2
ng h: 13'-2.9";
Lateral support: top=full, bottom=at supports;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Anal sis/Desi n
Shear fv = 47 Fv' = 144 fv Fv' = 0.33
Bending(+) fb = 901 Fb' = 1035 fb/Fb' = 0.87
Live Defl'n 0.25 = L/627 0.44 = L/360 0.57
Total Defl'n 0.44 = L/356 0.66 = L/240 0.67
� J
F] WoodWorks@ Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 125 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 900 1.15 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
FCp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.3 million 1.00 1'.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 1887, V design = 1650 lbs
Bending(+) : LC #2 = D+S, M = 6213 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 511e06 lb-int
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...}
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005),and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT
WoodWorks®
3IIf1YYARf FOl WOOD DE3ICN 4T 4_-J R -
Aug. 1, 2017 17:01 Beam1 V
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full UDL 86.0 plf
Load2 Snow Full UDL 190.0 plf
Self-weight Dead Full UDL 10.6 1plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
0' 9'
Unfactored:
Dead 436 436
Snow 859 859
Factored:
Total 1296 1296
Bearing:
Capacity 1296
Beam 1296
Supports 2036 2036
Anal/Des
Beam 1.00 1.00
Support 0.64 0.64
Load comb 42
Length 0.55 0.5555
Min req'd 0.55 0.55
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
Fcp sup 625 625
Timber-soft, S-P-F, No.2, 6x40 (5-112"x9-112")
Supports:All -Timber-soft Beam, D.Fir-L N0.2
Total length:9'-0.6"-,
Lateral support:top=full, bottom=at supports;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Analsis/Desi n
Shear fv = 30 Fv' = 144 fv Fv' = 0.21
Bending(+) fb = 421 Fb' = 690 fb/Fb' = 0.61
Live Defl'n 0.07 = <L/999 0.30 = L/360 0.24
Total Defl'n 0.13 = L/858 0.45 = L/240 0.28
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beaml WoodWorks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 125 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 600 1.15 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.0 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 1290, V design = 1056 lbs
Bending(+) : LC #2 = D+S, M = 2901 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 393e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Design Notes:
1. WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009), the
National Design Specification (NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT
WoodWorks
Aug. 1, 201717:18 Beaml
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Point 6.00 645 lbs
Load2 Snow Point 6.00 1570 lbs
Self-weight Dead Full UDL 10.6 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
12'-0.5"
01 12
Unfactored:
Dead 387 385
Snow 788 782
Factored:
Total 1175 1167
Bearing:
Capacity
Beam 1175 1169
Supports 1845 1836
Anal/Des
Beam 1.00 1.00
Support 0.64 0.64
Load comb #2 #2
Length 0.50 0.50*
Min req'd 0.50 0.50*
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
FCP SUP 1 625 625
'Minimum bearing length setting used: 1/2"for end supports
Timber-soft, S-P- No.1, 6x 0 (5-112"x9-112")
Supports:All -Tim er-soft eam, D.Fir-L No.2
TotalI X12'-0.5';
Lateral support: top=full, bottom=at supports;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005
Criterion Analysis Value Design Value Analysis/Design
Shear fv = 33 Fv' = 144 fv Fv' = 0.23
Bending(+) fb = 991 Fb' = 1035 fb/Fb' = 0.96
Live Defl'n 0.19 = L/753 0.40 = L/360 0.48
Total Defl'n 0.32 = L/445 0.60 = L/240 0.54
F� WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorksO Slzer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 125 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 900 1.15 1.00 1.00 1.000 1..000 1.00 1.00 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL_ LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 1175, V design = 1166 lbs
Bending(+) : LC #2 = D+S, M = 6835 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 511e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3.Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJECT
WoodWorks' � ,��
SO"WARK FON WOOD OEWN
Aug. 1,2017 17:15 Beam1
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full UDL 100.0 plf
Load2 Snow Full UDL 260.0 plf
Self-weight Dead Full UDL 1 10.6 Iplf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
— 9'-0.7"
0' 9'
unfactored:
Dead 501 501
Snow 1176 1178
Factored:
Total 1678 1678
Bearing:
Capacity
Beam 1678 1678
Supports 2636 2636
Anal/Des
Beam 1.00 1.00
Support 0.64 0.64
Load comb #2 #2
Length 0.72 0.72
Min req'd 0.72 0.72
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.07 1.07
- Fcp sup 625 625
Timber-soft, S-P-F, No.2, 6x10 (5.112"x9-112")
Supports: All-Timber-soft Beam, D.Fir-L No.2
Total length:9'-0.7";
Lateral support: top=full, bottom=at supports;
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Analysis/Design
Shear fv = 39 Fv' = 144 fv/Fv' = 0.27
Bending(+) fb = 544 Fb' = 690 fb/Fb' = 0.79
Live Defl'n 0.10 = <L/999 0.30 = L/360 0.33
Total Defl'n 0.16 = L/675 0.45 = L/240 0.36
4 .0
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 125 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 600 1.15 1.00 1.00 1.000 1.000 1.00 1.00 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.0 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 1668, V design = 1363 lbs
Bending(+) : LC 42 = D+S, M = 3752 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 393e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.Woodworks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005),and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3.Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
COMPANY PROJ CT
WoodlWorks®
-50"WNKIOY W000 Doxiv
Aug. 10, 2017 18:27 Beam1
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full Area 8.00 (16.0) * psf
Self-weight Dead Full UDL 1.1 if
*Tributary width (in)
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
i
91-1.611
1�
-r 1
0' $
Unfactored:
Dead 53 53
Factored:
Total 53 53
Bearing:
F'theta 488 488
Capacity
Joist 366 366
Supports 586 586
Anal/Des
Joist 0.14 0.14
Support 0.09 0.09
Load comb #1 #1
Length 0.50* 0.50*
Min req'd 0.50* 0.50*
Cb 1.00 1.00
Cb min 1.00 1'00
Cb support 1.25 1.25
Fc2 sup 625 625
*Minimum bearing length setting used: 112"for end supports
Lumber-soft, S-P-F, No.11No.2, 2x4 (1-112"x3-112")
Supports:All -Timber-soft Beam, D.Fir-L No.2
Roof joist spaced at 16.0"c/c; Total length: 9'-1.6'; Pitch: 6/12;
Lateral support: top= at supports, bottom=at supports; Repetitive factor: applied where permitted(refer to online
help);
F� WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks®Sizer 9.3 Page 2
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005:
Criterion Analysis Value Design Value Anal sis/Desi n
Shear fv = 12 Fv' = 121 fv Fv' = 0.10
Bending(+) fb = 411 Fb' = 1252 fb/Fb' = 0.33
Live Defl'n negligible
Total Defl'n 0.30 = L/355 0.60 = L/180 0.51
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 0.90 1.00 1.00 - - - - 1.00 1.00 1.00 1
Fb'+ 875 0.90 1.00 1.00 0.922 1.500 1.00 1.15 1.00 1.00 - 1
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 1
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 1
CRITICAL LOAD COMBINATIONS:
Shear : LC #1 = D only, V = 47, V design = 44 lbs
Bending(+) : LC #1 = D only, M = 105 lbs-ft
Bending(+) : LC #1 = D only
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = Be06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Bearing: Allowable bearing at an angle F'theta calculated for each support
as per NDS 3.10.3
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification (NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. SLOPED BEAMS: level bearing is required for all sloped beams.
COMPANY PROJECT
WoodWorkse ,���.�,-�(h�,
sorrw,U rFOR„1000 04SICN V,("f
Aug. 10, 2017 17:19 Beam1
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location (ft] Magnitude Unit
tern Start End Start End
Loads Dead Full Area 15.00 (16.0)* psf
Load2 Snow Full Area 40.00 (16.0) * psf
Self-weight Dead Full UDL 1.1 plf
*Tributary Width (in)
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in)
8'-0.7"
0' 6'-6"
Unfactored:
Dead 83 83
Snow 174 174
Factored:
Total 257 257
Bearing:
F'theta 546 546
Capacity
Joist 410 410
Supports 586 586
Anal/Des
Joist 0.63 0.63
Support 0.44 0.44
Load comb #2 #2
Length 0.50* 0.50*
Min req'd 0.50* 0.50*
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.25 1.25
Fcp sup 625 625
*Minimum bearing length setting used: 112"for end supports
Lumber-soft, S-P-F, NoAlNo.2, 2x4 (1-112"x3-112")
Supports: All -Timber-soft Beam, D.Fir-L No.2
Roof joist spaced at 16.0"c/c; Total length: 8'-0.7"; Pitch:8/12;
Lateral support: top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help);
This section FAILS the design check
WARNING: This section violates the following design criteria: Deflection
Y,f
WoodWorks@ Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks®Slzer 9.3 Page 2
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Analysis/Design
Shear fv = 56 Fv' = 155 fv/Fv' = 0.36
Bending(+) fb = 1627 Fb' = 1736 fb/Fb' n136 . t11 , ,
Live Defl'n 0.41 = L/227 0.39 = L/240 N
Total Defl'n 0.71 = L/132 0.52 = L/180 �}
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 675 1.15 1.00 1.00 1.000 1.500 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 213, V design = 196 lbs
Bending(+) : LC #2 = D+S, M = 415 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 8e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Bearing: Allowable bearing at an angle F'theta calculated for each support
as per NDS 3.10.3
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. SLOPED BEAMS: level bearing is required for all sloped beams.
COMPANY PROJECT
Q) WoodWorkse
so"W"f ioR*D00 MUCK
Aug. 10, 2017 17:15 Beam1U�`��
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Load1 Dead Full UDL 100.0 plf
Load2 Snow Full UDL 260.0 plf
Self-weight Dead Full UDL 5.6 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
0' 9'
Unfactored:
Dead 481 481
Snow 1184 1184
Factored:
Total 1665 1665
Bearing:
Capacity
Beam 1665 1665
Supports 2754 2754
Anal/Des
Beam 1.00 1.00
Support 0.60 0.60
Load comb #2 #2
Length 1.31 1.31
Min req'd 1.31 1.31
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.13 1.13
- Fcp sup 625 625
Lumber n-ply, S-P-F, No.1/No.2, 2x10, 2-ply(3"x9-1/4")
Supports:All -Timber-soft Beam, D.Fir-L No.2
Total length:9'-1.3";
Lateral support: top=full, bottom=at supports;
Analysis vs. Allowable Stress (psi) and Deflection (In) using NDS 2005 :
Criterion Analysis Value Design Value Anal sis/Desi n
Shear fv = 73 Fv' = 155 fv Fv' = 0.47
Bending(+) fb = 1038 Fb' = 1107 fb/Fb' = 0.94
Live Defl'n 0.14 = L/779 0.30 = L/360 0.46
Total Defl'n 0.22 = L/484 0.45 = L/240 0.50
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 Woodworks®Slzer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.100 1.00 1.00 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 1645, V design = 1344 lbs
Bending(+) : LC #2 = D+S, M = 3702 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow w=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI 139e06 lb-int/ply
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.Woodworks analysis and design are in accordance with the ICC International Building Code(IBC 2009), the
National Design Specification (NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. BUILT-UP BEAMS: it is assumed that each ply is a single continuous member(that is, no butt joints are present)
fastened together securely at intervals not exceeding 4 times the depth and that
each ply is equally top-loaded.Where beams are side-loaded, special fastening details may be required.
i
lark , R�
®Cerr--- 9,�rz:4vtv 1 5PITAL
( `Zoo
l.t, !u.4x, to
r ..�
0-2 oo
`c
COMPANY PROJECT
Q); Wbod'Works�
SUF7WMf FOI!'N"OUh DFSK.N 1 �"_ `+ �J
Aug. 11, 2017 10:46 Beam 1 �
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location (ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full UDL 60.0 plf
Load2 Dead Point 4.02 480 lbs
Load3 Snow Point 4.02 1200 lbs
,Self-weight IDead Full UDL 6.6 if
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in)
0' 8'
Unfactored•
Dead 508 508
Snow 600 600
Factored:
Total 1108 1108
Bearing:
Capacity
Beam 1108 1108
Supports 1765 1765
Anal/Des
Beam 1.00 1.00
Support 0.63 0.63
Load comb #2 ##2
Length 0.58 0.58
Min req'd 0.58 0.58
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.08 1.08
Fcp sup 625 625
Lumber n-ply, S-P-F, No.1/No.2, 2x8, 3-ply(4-112'W-1/4")
Supports:All-Timber-soft Beam, D.Fir-L No.2
Total length: 8'-0.6";
Lateral support: top=at supports, bottom=at supports; Repetitive factor: applied where permitted (refer to online
help);
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Analysis/Design
Shear fv = 49 Fv' = 155 fv/Fv' = 0.32
Bending(+) fb = 1185 Fb' = 1389 fb/Fb' = 0.85
Live Defl'n 0.11 = L/868 0.27 = L/360 0.41
Total Defl'n 0.22 = L/430 0.40 = L/240 0.56
2
r_1 F- WoodWorks@ Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC 42 = D+S, V = 1106, V design = 1065 lbs
Bending(+) : LC 42 = D+S, M = 3893 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow w=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 67e06 lb-in2/ply
"Live" deflection = Deflection from all non-dead loads (live, wind, snow.-)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009), the
National Design Specification (NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. BUILT-UP BEAMS: it is assumed that each ply is a single continuous member(that is, no butt joints are present)
fastened together securely at intervals not exceeding 4 times the depth and that
each ply is equally top-loaded.Where beams are side-loaded, special fastening details may be required.
tN
r
f
44 r O
Lq t::: k,PD
� t�
Y;'
�r
DL DNC
�--�
3 ,-2-6 x i 5.
5 i d.7
X cz
1z' Itl �F,
{ ll
wows
Technical Tip
ZIP System® R-Sheathing: Updates to ESR-3373
nr3 c
2009 & 2012 Code Recognition
In early 2013, the Acceptance Criteria used to evaluate proprietary sheathings, AC269,
was updated by International Code Council Evaluation Service (ICC-ES)to provide a
path for 2009 and 2012 code recognition. One of the biggest changes to the latest
AC269 is the requirement to evaluate panels that have been exposed to moisture. The
previous AC allowed panels to be tested for only dry conditions. This is an important
change because the new "wet" testing requirement is more representative of actual field
conditions. ZIP System R-sheathing is now recognized in Evaluation Service Report,
ESR-3373, for use in the 2009 and 2012 International Building Code (IBC), International
Residential Code (IRC) and International Energy Conservation Code (IECC). Currently,
R-Sheathing is the only insulated structural panel to achieve recognition under the
revised, more strenuous acceptance criteria.
Ignition Barrier Compliance
Due to the combustibility of foam, code requires that foam plastic insulation must be
separated from the interior of a building by an approved thermal barrier, such as '/z"
gypsum wallboard (See Section R316.4 in the 2012 International Residential Code).
Prior to 2014, ESR-3373 required that an approved thermal barrier be installed on walls
using ZIP System R-sheathing, in accordance with Chapter 26 of the IBC or Chapter 3
of the IRC, as applicable.
In 2014, the coated fiberglass facer on the ZIP System R-sheathing foam was tested to
comply with AC 12, the Acceptance Criteria used to evaluate thermal barriers. As a
result, ZIP System R-Sheathing is now code-recognized as a thermal barrier and may
be installed at gable end walls without the presence of an additional ignition barrier.
Huber Engineerzd Woods,LLC,10923 David Taylor Drive,Suite 300,Charlotte,NC 28262
Tel:900-933-9220,Fax:704-547-0739,www.huberwood.com
U
U IIYOODS
Fastening Options for Lateral Force Resisting Systems
ZIP System R-Sheathing panels may be designed to resist lateral shear forces by
prescriptive or engineered methods in accordance with the International Building and
Residential Codes. Panels may be used as a braced wall panel in accordance with the
WSP bracing method per the 2009 IRC* as an equivalent alternative to the prescribed
wood structural panels gnty if installed per Huber Engineered Woods installation
guidelines (see Table 1). Additionally, panels may be used in the design of engineered
shear walls per the 2009 and 2012 IBC.
R-Sheathing that is not used to resist wind or seismic loads may be attached to framing
using 8d common nails (or equivalent). Otherwise, see published fastener requirements.
ESR-3373 now provides builders with additional fastening options. Staples are now
recognized as an alternative to common nails in both prescriptive and engineered
designs under certain conditions.
'Currently,there is no Acceptance Criteria for proprietary sheathing to achieve 2012 IRC bracing recognition.
See Table 1 fastening options using 2009 IRC prescriptive wall bracing. See Table 2
fastening options for engineered shear walls per the 2009 and 2012 IBC. The structural
capacity of the R-sheathing is dependent on stud spacing, panel thickness, fastener
type/size used, and fastener spacing.
Prescriptive Method
TABLE 1: Fastening Requirements for ZIP System® -Sheathing with Framing of Douglas Fir-Larch2 for
Wind or Seismic Loading Under the 2009 IRC((W Method).
FRAMING FASTENERS
R- Maximum Nominal Stud Maximuma Edge/Field Spacing Minimum Penetration
TYPE' Size(mm.) Stud Spacing /Fastener Specifications (inches) into Framing(inches)
inches) /
R-3 2-by-4 24 0.131-inch shank nails 4/12 1.5
a staples,7/16-inch crown,2-
R-3 2-by-4 j' 16 inch length 3/6 1.0
0.13nails 4/12 1.5
1-in_� 5
R-6 2-by-4 24
15ga staples,7/16-inch n, 3/6 1.0
2.5-inch length
Huber Engineered Woods,LLC,10925 David Taylor Drive,Suite 300,Charlotte,NC 28262
Tel:800-933-9220,Fax:704-547-0739,www.huberwuod.com
EWANEERED
WOODS
nsaineered Met01 hod
TABLE 2: Fastening Requirements and Allowable Shear Capacity for ZIP System®R-Sheathing with
Framing of Douglas Fir-Larch2 for Wind or Seismic Loading Under the 2012 and 2009 IBC
R-
FRAMING FASTENERS ALLOWABLE
Maximum, Edge/Field SHEAR
SHEATHING Nominal Stud ; Minimum Penetration ss 7
TYPE'` Size(min.) Stud Spacing Fastener Specificaticros Spacing into Framing(inches) CAPACITY''
(inches) (inches) (plt)
R-3 2-by-4 24 0.131-inch shank nails 4/12 1.5 245
R-6 2-by-4 24 0.131-inch shank nails 3/6 1.5 215
R-3 2-by4 16 16ga staples,7/16-inch 3/6 1.0 210
crown,2-inch length
'All fasteners must be located a minimum of3/8 inch from panel edges.
'For framing of other species,the shear value above must be multiplied by the Specific Gravity Adjustment Factor=(1-(0.50—SG)],where SG=Specific Gravity of
the flaming lumber in accordance with the AF&PA NDS.This adjustment factor must not be greater than 1.
"Fasteners must be common nails or equivalent,or staples,of a type generally used to attach wood sheathing.
`type R-6 R-Sheathing panels have a foam plastic insulation thickness of 1.0 inch.Type R-3 R-Sheathing panels have a foam plastic insulation thickness of 0.5 inch.
sShearwalis must have a maximum height-to-width aspect ratio of 2:1.
brhe allowable shear capacity may be increased by 40%for wind in Allowable Stress Design in accordance with Section 23063 ofthe 2012 and 2009 IBC.
'All panel edges must be backed by framing.
Please visit www.zipsystem.com or contact our technical services department at
techguestions ftuber.com or at 1-800-933-9220 Ext. 2716 with any questions or
comments.
Huber Engineered Woods,LLC,10925 David Taylor Drive,Suite 300,Charlotte,NC 28262
Tel:800-933-9220,Fax:704-547-0739,www,huberwood.com
1�DA:
t/ 1 ,�°� it�—ft"c.—r J,�AL Q/i1� E-(✓`
%641'23) �� ' ,,232-
L,
Lu LWAV.� + 2Z1� �No� 4`Ao
� — 5 t _zC`q'c>) - z3
of
X65
F
(oma w wo)
�b
9 ,5
W r�, 6Qa' PDE,
71 '�-
�s �
d �
lu rtdi�AL-a.L,
C9 i7/q IY
iT
1 4-
2
JD LOPT'.
f �X�1 b"c..c� ? ''1.1 ► lea° { 'S
C
5 -� Low
IQ
Io
zT 61L
lb s
-
COMPANY PROJECT
Q, )' :WeodWorks
:o"WMrmrwoo*00"
Aug. 15, 201710:49 , Beam 1
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full UDL 15.0 plf
Load2 Snow Full UDL 51.0 plf
Load3 Dead Point 3.77 480 lbs
Load4 Snow Point 3.77 1200 The
,Self-weight Dead Full UDL 6.6 Plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
7'-6.6"
0' 7'-6"
Unfactored•
Dead 321 321
Snow 792 792
Factored:
Total 1114 1114
Bearing:
Capacity
Beam 1114 1114
Supports 1774 1774
Anal/Des
Beam 1.00 1.00
Support 0.63 0.63
Load comb #2 #2
Length 0.58 0.58
Min req'd 0.58 0.58
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.08 1.08
Fcp Sup 625 625
Lumber n-ply, S-P-F, No.1/No.2, 2x8, 3-ply (4-112"x7-114")
Supports:All-Timber-soft Beam, D.Fir-L No.2
Total length: 7'-6.6"-,
Lateral support:top=at supports, bottom=at supports; Repetitive factor: applied where permitted (refer to online
help);
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value ' Design Value Anal sis/Desi n
Shear fV = 49 Fv' = 155 fv Fv' = 0.32
Bending(+) fb = 1114 Fb' = 1389 fb/Fb' = 0.80
Live Defl'n 0.11 = L/823 0.25 = L/360 0.44
Total Defl'n 0.18 = L/513 0.38 = L/240 0.47
F� WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WOodWOrksO Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.200 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 1112, V design = 1067 lbs
Bending(+) : LC #2 = D+S, M = 3660 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 67e06 lb-in2/ply
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009), the
National Design Specification(NDS 2005),and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3.Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. BUILT-UP BEAMS: it is assumed that each ply is a single continuous member(that is, no butt joints are present)
fastened together securely at intervals not exceeding 4 times the depth and that
each ply is equally top-loaded.Where beams are side-loaded, special fastening details may be required.
COMPANY PROJECT
WoodW' or sy'f
#OFT*&"Felt WOOD amcly
Aug. 15, 2017 10:07 Beam1
Design Check Calculation Sheet
WoodWorks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full Area 15.00 (16.0) * psf
Load2 Snow Full Area 35.00 (16.0) * psf
Self-weight Dead Full UDL 3.4 Plf
*Tributary Width (in)
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
0. 19'
Unfactored:
Dead 223 223
Snow 445 445
Factored:
Total 669 669
Bearing:
Capacity
Joist 669 669
Supports 1229 1229
Anal/Des
Joist 1.00 1.00
Support 0.54 0.54
Load comb #2 #2
Length 1.05 1.05
Min req'd 1.05 1.05
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.25 1.25
Fcp sup 625 625
Lumber-soft, S-P-F, No.11 .2, 2x12 (1-112"x11-114")
Supports:All-Timber-so , D.Fir-L No.2
Roof joist spaced at 16.0"c/c;T al leng - J
Lateral support: top=full, bottom=at supports; Repetitive fac r: applied where permitted (refer to online help);
This section FAILS th design check
WARNING: This section violates the following design criteria: Bending
WARNING: Member length exceeds typical stock length of 18.0 [ft]
w
F1I Woodworks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks@ Sizer 9.3 Page 2
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Analysis Value Design Value Anal sis/Desi n_-
Shear fv = 53 Fv' = 155 fv Fv' = OAC 4
Bending(+) fb = 1199 Fb' = 1157 fb/Fb' = X1;04 �-
Live Defl'n 0.55 = L/415 0.95 = L/240 0.58
Total Defl'n 0.96 = L/236 1.27 = L/180 6
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.000 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 666, V design = 597 lbs
Bending(+) : LC #2 = D+S, M = 3162 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind 2=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 249e06 •1b-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification(NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
3
\r3`p� `q
1 -
i 1
—4-ji _ Y 2 Aoo3
i - —
A000 3 1s'-(r i3,-0, — _ •• —� -------
I 6'•$'f i 'i I
a) =J I Ii \— CWrMT UMIT LWE
i � .
I I
- - -- - _- - - - - - -`
' -i-L- ---------L------- -4-- I-----------------t 1
I 12 I A-oaaJ
I I
3 A-OW
EXTENT OF I A-0D4 { SOLID SURFACE I I - Wz W2 I I ! EDGE OF ROOF ABOVE
PAVED PATIO i �� I --� I
9'-43(4' $'-7174' I 9-(T 73' 0' 8'•7117 13'•1(
I I
1$'-0`
nAW
1
Li-
Zr
// 1
Aw
Gravity Beam Design ,
um RAM SBeam v5.0
6%
08/17/17 13:18:16
STEEL CODE: AISC 360-05 ASD
SPAN INFORMATION (ft): I-End (0.00,0.00) J-End (18.50,0.00)
Beam Size(User Selected) = WlOX22 Fy — 36.0 ksi
Total Beam Length (ft) = 18.50
Mp (kip-ft) = 78.00
Top flange braced by decking.
LINE LOADS(k/ft):
Load Dist(ft) DL LL
1 0.000 0.022 0.000
18.500 0.022 0.000
2 0.000 0.260 0.600
18.500 0.260 0.600
SHEAR: Max Va (DL+LL)=8.16 kips Vn/1.50=35.25 kips
MOMENTS:
Span Cond LoadCombo Ma @ Lb Cb fl Mn/f)
kip-ft ft ft kip-ft
Center Max + DL+LL 37.7 9.3 0.0 1.00 1.67 46.71
Controlling DL+LL 37.7 9.3 0.0 1.00 1.67 46.71
REACTIONS (kips):
Left Right
DL reaction 2.61 2.61
Max+LL reaction 5.55 5.55
Max+total reaction 8.16 8.16
DEFLECTIONS:
Dead load (in) at 9.25 ft = -0.217 L/D = 1022
Live load (in) at 9.25 ft = -0.462 L/D = 480
Net Total load(in) at 9.25 ft = -0.679 L/D = 327
COMPANY PROJECT
WoodWorks
50"W"E FOR WOOR B&MIi
Aug. 17, 2017 13:26 Beam1
Design Check Calculation Sheet
Woodworks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full UDL 110.0 plf
Load2 Snow Full UDL 257.0 plf
Self-weight Dead Full UDL 8.4 plf
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
0' 1'
Unfactored-
Dead 656 656
Snow 1425 1425
Factored:
Total 2081 2081
Bearing:
Capacity
Beam 2081 2081
Supports 3316 3316
Anal/Des
Beam 1.00 1.00
Support 0.63 0.63
Load comb #2 #2
Length 1.09 1.09
Min req'd 1.09 1.09
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.08 1.08
FCp Sup 625 625
Lumber n-ply, S-P-F, No.11No.2�tBe_-.�m
` x10 3-ply (4-112"x9-114") 7
`
Supports: All-Timber-soD.Fir-L No.2L(J ZTotal length: '-1.1";
Lateral support:top=full, bottom=at supports; Repetitive factor:applied where permitted(refer to online help);
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 :
Criterion Anal sis value Design Value Analysis/Design
Shear fv = 63 Fv' = 155 fv Fv' = 0.41
Bending(+) fb = 1062 Fb' = 1273 fb/Fb' = 0.83
Live Defl'n 0.20 = L/647 0.37 = L/360 0.56
Total Defl'n 0.34 = L/383 0.55 = L/240 0.63
_)
WoodWorks® Sizer SOFTWARE FOR WOOD DESIGN
Beam1 WoodWorks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.100 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC #2 = D+S, V = 2065, V design = 1758 lbs
Bending(+) : LC #2 = D+S, M = 5678 lbs-ft
Deflection: LC #2 = D+S (live)
LC #2 = D+S (total)
D-dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC's are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 139e06 lb-in2/ply
"Live" deflection = Deflection from all ncn-dead loads (live, wind, snow...)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009),the
National Design Specification (NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
4. BUILT-UP BEAMS: it is assumed that each ply is a single continuous member(that is, no butt joints are present)
fastened together securely at intervals not exceeding 4 times the depth and that
each ply is equally top-loaded. Where beams are side-loaded, special fastening details may be required.
COMPANY PROJECT
$OfJWAQEH}Y 4V00�OELLN
Aug. 17, 2017 13:25 Beam1
Design Check Calculation Sheet
Woodworks Sizer 9.3
Loads:
Load Type Distribution Pat- Location [ft] Magnitude Unit
tern Start End Start End
Loadl Dead Full Area 10.00 (16.0) * psf
Load2 Snow Full Area 35.00 (16.0) * psf
Self-weight Dead Full UDL 1.7 if
*Tributary Width (in)
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in)
11'-0.5"
01 11'
Unfactored•
Dead 83 83
Snow 258 258
Factored:
Total 341 341
Bearing:
Capacity
Joist 341 341
Supports 626 626
Anal/Des
Joist 1.00 1.00
Support 0.54 0.54
Load comb #2 #2
Length 0.53 0.53
Min req'd 0.53 0.53
Cb 1.00 1.00
Cb min 1.00 1.00
Cb support 1.25 1.25
Fcp sup 625 625
Lumber-soft, S-P-F, No.1/No.2, W (1-1/2"x5-112")
Supports: All -Timber-soft Beam, D.Fir-L No.2
Roof joist spaced at 16.0"c/c;Total length: 11'-0.5";
Lateral support:top=full, bottom=at supports; Repetitive factor: applied where permitted (refer to online help);
This section FAILS the design check
WARNING: This section violates the following design criteria: Deflection
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005
Criterion Analysis Value Design Value Analysis/Design
Shear fv = 56 Fv' = 155 fv/Fv' = 0.36
Bending(+) fb = 1480 Fb' = 1504 fb/Fb' = 0.98
Live Defl'n 0.53 = L/249 0.55 = L/240 0.96
Total Defl'n 0.78 = L/168 0.73 = L/180 1.07
F] WoodWorkS@ Sizer SOFTWARE FOR WOOD DESIGN
Beaml Woodworks®Sizer 9.3 Page 2
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC#
Fv' 135 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2
Fb'+ 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 - 2
Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - -
E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 2
Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 2
CRITICAL LOAD COMBINATIONS:
Shear : LC 42 = D+S, V = 339, V design = 310 lbs
Bending(+) : LC #2 = D+S, M = 933 lbs-ft
Deflection; LC #2 = D+S (live)
LC #2 = D+S (total)
D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake
All LC' s are listed in the Analysis output
Load combinations: ASCE 7-05 / IBC 2009
CALCULATIONS:
Deflection: EI = 29e06 lb-in2
"Live" deflection = Deflection from all non-dead loads (live, wind, snow...)
Total Deflection = 1.50 (Dead Load Deflection) + Live Load Deflection.
Design Notes:
1.WoodWorks analysis and design are in accordance with the ICC International Building Code(IBC 2009), the
National Design Specification(NDS 2005), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
fib"
All- I-
V t
N
C,-7`^^P(I�S!D AS
l
FIRE MARSHAL'S OFFICE
Toum of Queensbury
742 Bay Road, Queensbury, NY 12804
"Home of Natural Beauty ... A Good Place to Live "
PLAN REVIEW
ADK Animal Hospital
Ridge Road
CO-000521-2017
9/12/2017
The following comments are based on review of drawings:
• Verify operation of exit / Emergency lighting. Suggest a combo pak in the
building and remote emergency lighting heads outside each door.
• Lock / latches shall comply with Chapter 10 of 2015 IBC.
• Knox box required at exterior
Michael J Palmer
Fire Marshal
742 Bay Road
Queensbury NY 12804
firemarshal@queensbury.net
Fire Marshal 's Office • Phone: 518-761-8206 ■ Fax: 518-745-4437
-flremarshal@queensbupj.net - zuzuw.queensburt