Loading...
Final 04172018 INSPECTION WORKSHEET (002676-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000585-2017Case Module:Permit Inspection Date:04/17/2018Inspection Status:Passed Inspector:Charles DyerInspection Type:Residential Final Inspection Job Address:18 ALESSIA DRParcel Number:315.10-1-44 Queensbury, NY 12804 Contact TypeCompany NameName Applicant\[CERRONE BUILDERS, INC.\], Contractor\[CERRONE BUILDERS, INC.\], Granted Permission\[CERRONE BUILDERS, INC.\], Primary Owner\[CERRONE BUILDERS, INC.\], Electrical Contractor\[Middle Department\], Checklist ItemPassedComments General CommentsNO 4 inch Building Number Address visible from roadYES Chimney Height / B Vent / Direct Vent LocationYES Fresh Air IntakeYES 3" Plumbing Vent through roof minimum 18 inchYES Outside Spigots have Air GapYES Roof Complete / Exterior Finish CompleteYES Platform at all exterior doorsYESProvide steps at front entry Verified 4/17/18 Handrail 4 or more risersYES Guards at stairs,decks,patios 30" + above gradeYES Guard at stairwell at 34" or moreYES Window guards req:<2' above floor/6' above grade - quick releaseYES installed Guard at deck, porches 36" or moreYES Handrail Termination at Newell Post or WallYESAt basement Interior/Exterior Railings 34 to 38YES Wood deck: 2'+ from grade dia bracing required - H/C ramp compliantYES 4+ Deck Joist Ledger Connections-24" From EndsYES Deck Ledger-Bolted per CodeYES Grade away from foundation 6 with 10 feetYES 6 clearance to sill plateYES Gas Shut-off Exposed & Regulator (18) Above GradeYES Interior privacy/trim/doors/main entrance 36YES Bathroom / Kitchen WatertightYES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucetYES Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drsYES Smoke Detectors: Carbon MonoxideYES Smoke Detectors 3' from Kitchens & Baths R314YES Apr 17, 2018Page (3) INSPECTION WORKSHEET (002676-2018) Checklist ItemPassedComments Every level, Every bedroomYES Outside every bedroom areaYES Inter ConnectedYES Battery backup: _____YES Attic Access 22 x 30 minimumYES Attic Access Insulation = Attic R- ValueYESProvide insulation certification Received 4/12/18 Attic Access GasketedYES Bathroom Fans, if no windowYES Plumbing fixturesYES Backflow Preventors where requiredYES Foundation insulation to floorYES Energy Sticker on Elec. Panel:R-Val. & Heating SysYES All Hot Water Systems: R-3YES Duct work sealed properlyYES Intake OpeningsYES Blower Door Test CertificationYES Emergency egress below gradeYES Furnace shut-off w/in 30 ft. or w/in line of siteYES Furnace Hot Water Heater operatingYES Relief Valve ,Heat Trap/Water Temp 110 deg or lessYES 20 Minute Fire Door/Self-Closing HardwareYES Seals on Garage Doors, esp. WoodYES Basement stairs closed rise greater than 4 inchesYES Basement Egress: 5s.f. window w/sill or Bilco doorYESWalk out Garage Floor PitchedYES Gas Log In Sealed or Glass EnclosureYES Fin Elect; Energy Saving Light Bulbs 50 PercentYES Final Survey Plot PlanYESProvide final survey Received 4/17/18 Arc Fault Breaker Habitable SpacesYES Flex Gas Pipe BondingYES As Built Septic SystemYESProvide engineer asbuilt report Received 4/17/18 Truss ID Signage Installed at Electrical MeterYES OK to Issue Temporary C/ONO OK to Issue C/OYES Dyer, Charles (Inspector) Apr 17, 2018Page (4)