Loading...
manual J Load Short Form Job: 1040 SF HOUSE 4- Wrightsoft Date: 5.24.17 Entire House By: GRJ LARRY CLUTE Project Information For: CLUTE ENTERPRISES Design Information Htg Clg Infiltration Outside db (°F) -20 95 Method Simplified Inside db (°F) 70 70 Construction quality Average Design TD (°F) 90 25 Fireplaces 1 (Average) Daily range - M Inside humidity(%) 30 50 Moisture difference (gr/Ib) 31 58 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade AMERISTAR Trade AMERISTAR Model M951PO60BU36 Cond M4AC3024B1 AHRI ref 131401899979719457 Coil AHRI ref Efficiency 95 AFUE Efficiency 13 SEER Heating input 60000 Btuh Sensible cooling 0 Btuh Heating output 57000 Btuh Latent cooling 0 Btuh Temperature rise 54 °F Total cooling 0 Btuh Actual air flow 953 cfm Actual air flow 800 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftp) (Btuh) (Btuh) (cfm) (cfm) BASEMENT 1040 12368 2462 297 98 BEDROOM 1 208 4520 3299 108 131 BEDROOM 2 154 2697 1815 65 72 FULL BATH 77 987 585 24 23 BR1 BATH 72 1999 1550 48 62 LIVING ROOM 216 6479 3585 155 143 KITCHEN/DINING RM 266 10671 6778 256 270 Entire House d 2033 39721 20074 953 800 Other equip loads 0 0 Equip. @ 1.00 RSM 20074 Latent cooling 4908 TOTALS 2033 39721 24982 953 800 BoWtalic values have been manually overridden Calculations approved byACCA to meet all requirements of Manual J 7th Ed. Wf 1 htSOf 2017-May-2509:13:00 ,,r Right-Suite®Universal 2013 13.0.08 RSU20185 Page 1 ACCP. ...JOBS\CLUTE_ENTERPRISES\CLUTE_1040SF_5_24_17.rup Calc=MJ7 faces: N MODEL HR100V R (Heat Recovery Ventilators (HRV)) P:800.961.7370 Hill www.solerpalau-usa.com CERTIFIED Specifications Energy Performance (Heating) Polypropylene HRV Core:cross-flow that transfers sensible heat Supply Net Air Flow Power Sensible Apparent Typical ical Airflow Range:30-100 CFM Temperature 9 Consumed Recovery Sensible Duct Connections:Four(4)5"oval ISF double collar system °F °C CFM Us (Watts) Efficiency Effectiveness Number Motors:Two(2)PSC variable speed backward curved 32 0 40 19 28 64 72 V Hz Phase Amperage 32 0 65 30 40 59 66 120 60 Single 0.85 A/66 watts -13 25 37 18 30 55 73 Exchange surface:63.5 ft2 Ventilation Performance Defrost type:Evacuation Filters:Two(2)Fiberbond washable External Static Net Gross Air Gross Pressure Air Flow Flow Air Flow Drain Connection:112" Supply Exhaust DuoTrol:Integrated Balancing System Pa in.w.g. Us CFM Us CFM Us CFM Weight:33.5 lbs(unit),41 lbs(in carton) 25 0.1 47 99 48 100 48 102 Dimensions:22"W x 19-13/16"L x 14-19/32"H 50 0.2 44 93 45 94 43 92 Options: 75 0.3 39 83 40 84 38 80 HRT-3-Push Button Timer HRRD-1 -Dehumidistat 100 0.4 35 75 35 75 36 78 HRRD-3P-Dehumidistat 125 0.5 30 65 30 66 32 68 150 0.6 27 56 27 57 25 52 Dimensions 175 0.7 22 46 22 47 19 41 Front View Top View 247.9 mm 2.1 52..55 mm 17.1" 14.6„ 1.1" 448.8 m 371 m 27.9 mm 28..55 mm 5"oval 20" � 127 mm 507 mm Minimum Clearance Data Front View Ceiling Top View • • 15 361 mm Minimum clearance for balancing 12" Wall Wall 305 mm —IF _I Minimum door clearance �l �5_o 50.8 mm 3" .8 mm 76.2 mm Minimum clearance for drain fitting Recomended minimum clearance for"P"trap of 10"(254 mm) For more information contact us at www.solerpalau-usa.com or 1.800.961.7370 for additional submittal drawings. S&P will not be responsible for fabrication changes or errors resulting from customer use of a non-current submittal drawing. Soler&Palau Ventilation Group HR100V_Submittal-12.12.2013