RC-000611-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building& Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000611-2017 Date Issued: Friday, August 17, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000611-2017
has been completed.
Tax Map Number: 308.18-1-63
Location: 28 NORTH CHURCH LN
Owner: JOHN MOSSING II
Applicant: Tech East Fire and Water Restoration
This structure may be occupied as a: Single Family Addition 286 s.f.
(fire restoration) By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, avv
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
�!+ Community Development-Building& Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000611-2017
Tax Map No: 308.18-1-63
Permission is hereby granted to: JOHN MOSSING II
For property located at: 28 CHURCH LN
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvne of Construction
Owner Name: JOHN MOSSING II Single Family-Addition $225,000.00
Owner Address: 28 N Church LN Total Value $225,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Tech East Fire and Water Restoration
28 Emerick LN
Albany,NY 12211
Plans&Specifications
Single Family Addition 286 s.f.
(fire restoration)
$100.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,November 19,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.
Dated at the To of Quee ury; 4tem—ber 17,2017
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
ADDITION/ALTERATION PERMIT Permit#: QC'lo_\\
APPLICATION Permit Fee:$ 100
'town of Queensbury
742 Bay Road,Queensbury,NY 12804 Invoice#: 2—Zb T
P:518-761-8256 www.gueensbury.net
fIa —
Project Location: 2,6 N. �r� .
Tax Map ID #: 18 Subdivision Name: r`l 7 .4(10Se G�01 A—
CONTACT INFORMATION:
• Applicant:
Name(s): 1"I�'P 4410 A1(..d 4,K or A417
Mailing Address, C/S/Z�9S: ���,�/� /iv %f X,4: /,I,
Cell Phone: Land Line: ( )
Email: &,JLtl,4-r �-e ro,,
• Primary Owner(s):
Name(s): Ira-41, /�o.1Siy� /
Mailing Address, C/S/Z: 9-zt' r,-H C/i,rG/i ,e,9 62veerzf4
Cell Phone: ( S/8" 37GJd Land Line: ( )
Email:
• Contractor(s):
Business Name: ' 7eZ A/1-e A41e,--s ah
Contact Name(s):
Mailing Address, C/S/Z:
Cell Phone: Land Line: ( )
E m a i I: . war �,��/%se Zda Aer, 6>n.
D E C ETVV
• Arch itect(s)/Engineer(s):
Business Name: C.�/A/ 4,-c4;1cclk r . SEP Z 8 2017
Contact Names 12,4 4mo
Mailing Address, C/S/Z: l r����ii s C04! -f �iY /10 tv�i DI uuttCoGQ Y
Cell Phone: (, llr S3 /�/�/ _ Land Line: .
Email: r- 4,141AI-c -Ac/L e
Contact Person for Building & Code Compliance:
Cell Phone: f6`q -7tf� Land Line: ( )
Email:
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
INSPECTION WORKSHEET (006009-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:
Inspection Date:
Inspector:
Case Module:
Inspection Status:
Inspection Type:
RC-000611-2017
08/17/2018
John O'Brien
Permit
Passed
Residential Final Inspection
Job Address:Parcel Number:28 NORTH CHURCH LN
Queensbury, NY 12804
308.18-1-63
Contact Type Company Name Name
Primary Owner MOSSING II, JOHN
Contractor Tech East Fire and Water Restoration [Tech East Fire and Water Restoration] ,
Applicant Tech East Fire and Water Restoration [Tech East Fire and Water Restoration] ,
Architect Capital Architecture [Capital Architecture] ,
Solid Fuel Contractor Adirondack Hearth Home & More [Adirondack Hearth Home & More] ,
Granted Permission MOSSING II, JOHN
Checklist Item Passed Comments
General Comments YES 8/10/18 Final Inspection Not Approved
-Provide Insulation installation field report from
contractor on what R values installed in ceiling, walls,
floors, and basement walls.
-Rear garage entry door needs exterior landing.
-Spray foam exposed on basement walls needs
appropriate fire block sealant installed.
-Install handrail on Basement Stairs
-Install guards on both sides of bottom of basement
stairs.
-Condensate Lines for furnace and HRV unit need to go
directly into in line trap. No barb fittings repair pipe.
-Drop down stairs in garage needs to be 20 minute
rating.
-Need to bond existing csst piping for fireplace.
8/17/18 Final Inspection Approved
Ok to issue CO!
4 inch Building Number Address visible from road YES
Chimney Height / B Vent / Direct Vent Location YES
Chimney Rain Cap Installed YES
Fresh Air Intake YES
Fresh air supply 3' from grade YES
3" Plumbing Vent through roof minimum 18 inch YES
Roof Complete / Exterior Finish Complete YES
Platform at all exterior doors YES -Rear garage entry door needs exterior landing.
Handrail 4 or more risers YES -Install handrail on Basement Stairs
Guards at stairs,decks,patios 30" + above grade YES
Guard at stairwell at 34" or more YES -Install guards on both sides of bottom of basement
stairs.
Aug 17, 2018 Page (1)
INSPECTION WORKSHEET (006009-2018)
Checklist Item Passed Comments
Window guards req:<2' above floor/6' above grade -
quick release installed
YES
Guard at deck, porches 36" or more YES
Handrail Termination at Newell Post or Wall YES -Install handrail on Basement Stairs.
Interior/Exterior Railings 34 to 38 YES -Install handrail on Basement Stairs
Grade away from foundation 6 with 10 feet YES
6 clearance to sill plate YES
Gas Shut-off Exposed & Regulator (18) Above Grade YES
HVAC Vent Terminal 10' from Lot Line & Openings YES
Dryer Duct Max Length 35', Labeled Over 35'YES
Interior privacy/trim/doors/main entrance 36 YES
Bathroom / Kitchen Watertight YES
Low flow toilet 1.3 gal/flushing cycle -
showerhead/faucet
YES
Safety glazing: w/in 5' of tub/shower - stairwell win/adj to
drs
YES
Smoke Detectors: Carbon Monoxide YES
Smoke Detectors 3' from Kitchens & Baths R314 YES
Every level, Every bedroom YES
Outside every bedroom area YES
Inter Connected YES
Battery backup: _____YES
Attic Access 22 x 30 minimum YES
Attic Access Insulation = Attic R- Value YES
Attic Access Gasketed YES
Bathroom Fans, if no window YES
Plumbing fixtures YES
Foundation insulation to floor YES
Energy Sticker on Elec. Panel:R-Val. & Heating Sys YES
Duct work sealed properly YES
Aug 17, 2018 Page (2)
INSPECTION WORKSHEET (006009-2018)
Checklist Item Passed Comments
Intake Openings YES
Blower Door Test Certification YES
HRV or ERV Installed per Bedroom Requirements YES
Furnace shut-off w/in 30 ft. or w/in line of site YES
Furnace Hot Water Heater operating YES
Relief Valve ,Heat Trap/Water Temp 110 deg or less YES
1/2" Gypsum or House Wall and Gable YES -Drop down stairs in garage needs to be 20 minute
rating.
5/8" Type X with Living Space Above YES
20 Minute Fire Door/Self-Closing Hardware YES -Drop down stairs in garage needs to be 20 minute
rating.
Seals on Garage Doors, esp. Wood YES
Basement stairs closed rise greater than 4 inches YES
Garage Floor Pitched YES
Fin Elect; Energy Saving Light Bulbs 50 Percent YES
Arc Fault Breaker Habitable Spaces YES
Flex Gas Pipe Bonding YES -Need to bond existing csst piping for fireplace.
Truss ID Signage Installed at Electrical Meter YES
Aug 17, 2018 Page (3)
INSPECTION WORKSHEET (006009-2018)
Checklist Item Passed Comments
OK to Issue C/O YES 8/10/18 Final Inspection Not Approved
-Provide Insulation installation field report from
contractor on what R values installed in ceiling, walls,
floors, and basement walls.
-Rear garage entry door needs exterior landing.
-Spray foam exposed on basement walls needs
appropriate fire block sealant installed.
-Install handrail on Basement Stairs
-Install guards on both sides of bottom of basement
stairs.
-Condensate Lines for furnace and HRV unit need to go
directly into in line trap. No barb fittings repair pipe.
-Drop down stairs in garage needs to be 20 minute
rating.
-Need to bond existing csst piping for fireplace.
8/17/18 Final Inspection Approved
Ok to issue CO!
Aug 17, 2018 Page (4)
O'Brien, John (Inspector)
INSPECTION WORKSHEET (005796-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:
Inspection Date:
Inspector:
Case Module:
Inspection Status:
Inspection Type:
RC-000611-2017
08/10/2018
John O'Brien
Permit
Failed
Residential Final Inspection
Job Address:Parcel Number:28 NORTH CHURCH LN
Queensbury, NY 12804
308.18-1-63
Contact Type Company Name Name
Primary Owner MOSSING II, JOHN
Solid Fuel Contractor Adirondack Hearth Home & More [Adirondack Hearth Home & More] ,
Applicant Tech East Fire and Water Restoration [Tech East Fire and Water Restoration] ,
Contractor Tech East Fire and Water Restoration [Tech East Fire and Water Restoration] ,
Architect Capital Architecture [Capital Architecture] ,
Granted Permission MOSSING II, JOHN
Checklist Item Passed Comments
General Comments NO 8/10/18 Final Inspection Not Approved
-Provide Insulation installation field report from
contractor on what R values installed in ceiling, walls,
floors, and basement walls.
-Rear garage entry door needs exterior landing.
-Spray foam exposed on basement walls needs
appropriate fire block sealant installed.
-Install handrail on Basement Stairs
-Install guards on both sides of bottom of basement
stairs.
-Condensate Lines for furnace and HRV unit need to go
directly into in line trap. No barb fittings repair pipe.
-Drop down stairs in garage needs to be 20 minute
rating.
-Need to bond existing csst piping for fireplace.
4 inch Building Number Address visible from road YES
Chimney Height / B Vent / Direct Vent Location YES
Chimney Rain Cap Installed YES
Fresh Air Intake YES
Fresh air supply 3' from grade YES
3" Plumbing Vent through roof minimum 18 inch YES
Roof Complete / Exterior Finish Complete YES
Platform at all exterior doors NO -Rear garage entry door needs exterior landing.
Handrail 4 or more risers NO -Install handrail on Basement Stairs
Guards at stairs,decks,patios 30" + above grade YES
Guard at stairwell at 34" or more NO -Install guards on both sides of bottom of basement
stairs.
Window guards req:<2' above floor/6' above grade -
quick release installed
YES
Aug 10, 2018 Page (1)
INSPECTION WORKSHEET (005796-2018)
Checklist Item Passed Comments
Guard at deck, porches 36" or more YES
Handrail Termination at Newell Post or Wall NO -Install handrail on Basement Stairs.
Interior/Exterior Railings 34 to 38 NO -Install handrail on Basement Stairs
Grade away from foundation 6 with 10 feet YES
6 clearance to sill plate YES
Gas Shut-off Exposed & Regulator (18) Above Grade YES
HVAC Vent Terminal 10' from Lot Line & Openings YES
Dryer Duct Max Length 35', Labeled Over 35'YES
Interior privacy/trim/doors/main entrance 36 YES
Bathroom / Kitchen Watertight YES
Low flow toilet 1.3 gal/flushing cycle -
showerhead/faucet
YES
Safety glazing: w/in 5' of tub/shower - stairwell win/adj to
drs
YES
Smoke Detectors: Carbon Monoxide YES
Smoke Detectors 3' from Kitchens & Baths R314 YES
Every level, Every bedroom YES
Outside every bedroom area YES
Inter Connected YES
Battery backup: _____YES
Attic Access 22 x 30 minimum YES
Attic Access Insulation = Attic R- Value YES
Attic Access Gasketed YES
Bathroom Fans, if no window YES
Plumbing fixtures NO
Foundation insulation to floor NO
Energy Sticker on Elec. Panel:R-Val. & Heating Sys NO
Duct work sealed properly YES
Intake Openings YES
Blower Door Test Certification YES
HRV or ERV Installed per Bedroom Requirements YES
Furnace shut-off w/in 30 ft. or w/in line of site YES
Furnace Hot Water Heater operating YES
Relief Valve ,Heat Trap/Water Temp 110 deg or less YES
1/2" Gypsum or House Wall and Gable NO -Drop down stairs in garage needs to be 20 minute
rating.
Aug 10, 2018 Page (2)
INSPECTION WORKSHEET (005796-2018)
Checklist Item Passed Comments
5/8" Type X with Living Space Above YES
20 Minute Fire Door/Self-Closing Hardware NO -Drop down stairs in garage needs to be 20 minute
rating.
Seals on Garage Doors, esp. Wood YES
Basement stairs closed rise greater than 4 inches YES
Garage Floor Pitched YES
Fin Elect; Energy Saving Light Bulbs 50 Percent YES
Arc Fault Breaker Habitable Spaces YES
Flex Gas Pipe Bonding NO -Need to bond existing csst piping for fireplace.
Truss ID Signage Installed at Electrical Meter YES
OK to Issue Temporary C/O NO 8/10/18 Final Inspection Not Approved
-Provide Insulation installation field report from
contractor on what R values installed in ceiling, walls,
floors, and basement walls.
-Rear garage entry door needs exterior landing.
-Spray foam exposed on basement walls needs
appropriate fire block sealant installed.
-Install handrail on Basement Stairs
-Install guards on both sides of bottom of basement
stairs.
-Condensate Lines for furnace and HRV unit need to go
directly into in line trap. No barb fittings repair pipe.
-Drop down stairs in garage needs to be 20 minute
rating.
-Need to bond existing csst piping for fireplace.
Aug 10, 2018 Page (3)
INSPECTION WORKSHEET (005796-2018)
Checklist Item Passed Comments
OK to Issue C/O NO 8/10/18 Final Inspection Not Approved
-Provide Insulation installation field report from
contractor on what R values installed in ceiling, walls,
floors, and basement walls.
-Rear garage entry door needs exterior landing.
-Spray foam exposed on basement walls needs
appropriate fire block sealant installed.
-Install handrail on Basement Stairs
-Install guards on both sides of bottom of basement
stairs.
-Condensate Lines for furnace and HRV unit need to go
directly into in line trap. No barb fittings repair pipe.
-Drop down stairs in garage needs to be 20 minute
rating.
-Need to bond existing csst piping for fireplace.
Aug 10, 2018 Page (4)
O'Brien, John (Inspector)
* fi
aLr-
s. , A _ 1 ,.
4.,t, ' f : ' ''''',:ll'fie/t ',.s.' "','"fir I -1----.-1::-:!...e,:--..„.i.--, , z-.,A'---;,,V,1- " '
1
a - IF
a , .
..*-
=11 V S ';;
f 5
2:2 A t ) ''''"
45.1 i '
1111111111111111
6 s " A.-
f, '�6 443
T
›' i
f.. s_
3,
iv .. _
..,,
. ._
t,; - , . .
1
,sf
ri. ii 1 -3'
1 {!t (
, . •s .
e
....
..... . •
, . 4
0
O7
rCEIIVIE0
Builders Installed Products(345) Job Number: 3796890
136 Tivoli Street AUG 16 2016
Albany,NY 12207 TOWN OF QUEENSBURY
BUILDING&CODES
nsu a ion e l -1 e
Insulation is installed in the structure described below as follows:
Work Area Item Installed Bags / Sq Feet
Per Window Foam 00793 Tytan Pro Window&Door 24oz
Vents 11.25x48 Foam Baffles
Poly Ceiling 4MIL 8'X100'CLEAR
Poly Walls 4MIL 8'X100'CLEAR
Poly Walls 4MIL 9'X100'CLEAR
Foundation Walls JM Corbond Closed-Cell 2"R-14.00
Foundation Walls R-13 15"x 93"-Kraft-Batts
Walls R-13 15"x 93"-Unlaced-Wood Framing
Foundation Walls R-16 WMP-VR MBI 2-3"Tabs
Exterior Garage Walls R-19 15"x 105"-Kraft-Batts
Exterior Garage Walls R-19 15"x 93"-Kraft-Wood Framing
Walls R-21 15"x 93"-Unlaced-Wood Framing
Blockers and Runners R-21 15"x 93"-Unlaced-Wood Framing
Basement Blockers R-21 15"x 93"-Unlaced-Wood Framing
Overhang R-30 16"x 48"-Kraft-Wood Framing
Ceiling R-38 Thermaglas II Loosefill Fiberglass
Garage Ceilings. R-38 Thermaglas II Loosefill Fiberglass
Ceiling R-49 24"x 48"-Kraft-Batts
Foundation Walls RFF54 Reinforced Foil Scrim Paper
"Fiberglass blow has no settling factor for R-values
Job Name: 28 NORTH CHURCH RD
Job Address: 28 NORTH CHURCH RD
QUEENSBURY,NY 12804
•
Date Completed: " 13— ,D .
Builders Installed Products W.0 _�
Insulation By: -_
D
E C E~a W E MODEL HR160H
S (Heat Recovery Ventilators (F1RV))
& NOV 2 2011
TOWN OF QUEENSBURY
P:800.961 7370 BUILDING&CODES NVI
www.solerpalau-usa_corn CERTIFIED
u
Specifications Energy Performance (Heating)
Polypropylene HRV Core:cross-flow that transfers sensible heat Supply Net Air Flow Power Sensible Apparent
Temperature Consumed Recovery Sensible
Typical Airflow Range:30-160 CFM �
Duct Connections:Four(4)6"dia. ISF double collar system "F "C CFM Us (watts) Efficiency Effectiveness
Number Motors:Two(2)PSC variable speed backward curved 32 0 1 65 31 1 72 66 75
VHz Phase Amperage 32 0 83 39 80 63 72
120 60 Single 1.5 A/142 watts 32 0 107 5o 94 60 67
Exchange surface:85 ft' 13 1 36 72 56 73
Defrost type: Evacuation
Ventilation Performance
Filters:Two(2)Fiberbond washable
Grass Air Gross
Drain Connection:112" External Static Net Flow Air Flow
DuoTrol:Integrated Batancing System Pressure Air Flow Supply Exhaust
Weight:43 lbs(unit).49 lbs(in carton) Pa in.w.g. Us CFM Us CFM Us CFM
Dimensions:29-112"W x 22.112"L x 11-3/8"H 25 0.1 91 193 91 194 103 217
Options: 50 0.2 84 178 85 179 95 201
HRT-3-Push Button Timer 75 0.3 77 163 77 163 86 183
HRRD-1 -Dehumidistat
HRRD-3P-Dehumidistat 100 0.4 71 150 li 151 80 169
125 0.5 63 133 63 134 71 152
150 0.6 57 120 57 121 66 138
175 0.7 51 109 51 109 57 121
Dimensions
Front View Top View
--4t2.8'
7 2.8"
2 4 mm ,t 5^
`I �_126mm
2, s' 11�— ..
545 9 mm 6", 297.6 mm ✓V k t��v r-ilz�-�' +L • .
152.5 mm
140.5 mm
23.3'
606 3 mm
Minimum Clearance Data
Front View Minimum plug Top View
clearance
3"
76.2 mm ., .
305 mn
Minimum door clearan
'I� ,. 15"
Wal — 38115mm 381 mm--1Wal
3..T Minimum clearance for drain fitting
76.2 mm Recomended minimum clearance
for"P"trap of 10"(254 mm)
For more information contact us at www.solerpalau-usa.com or 1.800.961.7370 for additional submittal drawings.
S&P will not be responsible for fabrication changes or errors resulting from customer use of a non-current submittal drawing.
Soler&Palau
Ventilation Group
HR160H Su6miLtaB-12 12 2013
nub. U. LVIU MU1H No. 440D Y• )/�
•
Middle Department Insp ection Agency, Inc.
• • 410 Troy-Schenectady Road
• ' , Suite -102
Latham, NY 12110
(518)273-0861
•
•
R-G - kit t k • LC)
File No. 141557104312 j
HE 0 1
71 AUG 0 6 LI2o18fl
Re• 28 North Church Queensbury, NY I OWN OF QUE NSSURc i' •
BUILDING&CODES
•
•
Pursuant to your request, inspection of the visible portion
only of the electrical installation in the above! property was
completed on Aug 2, 2018.
This letter indicates compliance with applicable Code
requirements at the time of our inspections except as may be noted
below.
Yours Truly,
MDIA
•
•
•
This letter shall be valid for a period of one year' from the above noted date.
Should the Electrical System to which this approval applies be altered in any
way, including but not limited to, the introduuctiotn of additional electrical
equipment and/or replacement of any of the components inspected this date, this
approval shall be null and void.
`Y/1 u g. b. 2IJ 1 U" i3;Z4AIVIO >1VIU l AW ...,.. .1 ; ,,.> •,- :•• .,, ,\,.<�-c�-• •. -',,, .N 0. 4465 .,• P. 4/5. �..„
MIDDLE DEPARTMENT INSPECTION AGENCY, INC.
W orl 'cer that the electrical wiring to the electrical equipment listed bOow has been examined and is approved as
lki being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date i 1 noted below and is issued subject to the following conditions. 1..:1
�
6.e;). Owner: • Date: ``
�,� Unknown 06'02/2018• y
f.0 Occupant: Addition • Locatio ��
n28 North Church
0 Occupancy- QueLnsbury,Warren Co- NY •
tkc, Single Family Dwg. I fir)
Applicant: i :-
,,: Graves Electrical Cont ,
4 126 Dumbarton Drive 2� �` 1,1x
Delmar, NY 12054 .. - .:. . . .. . ,..,'"A— l v ?o
f 7"a� �>)
e.l. . , .. . .... ,,,,,,,,,,___Steven Reynolds : �J�
<> No. AUG u 6 2018 <*
ra 041557104311:FL'; I _ _ �{ _ ,f
TOWANDF
'.0 Equipment: •
. . • I • • 6� i °0PVRY fir`,
,Oats
,8-Switches; 11 -Receptacles; 18-Fixtures ' '
//�` rve4
`� • • O1
`-" • ., )
co I
4 yt This cefilcate applies to the electrical wiring to the electrical equipment listed immediately null and Laid. This certificate applies only,to the use,occupancy and
<j:) above and the Installation Inspected as of the above noted date based on a visual ownership as Indicate0 herein. Upon a change in the use,occupancy or ownership <<
t:,) inspection, No warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. .0
ciency or fitness of the equipment for any particular purpose. This certificate shalt In the event that this certificate becomes invalid based upon me above conditions,
�V be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon relnspection by Middle Department S�2
%)) system to Which this certificate applies be altered in any way,including but riot emit- Inspection Agency.Inc. An application for inspection must be submitted to Middle (0,,.
6 ed to,the introduction of additional electrical equipment and/or the replacement of, Department Inspection Agency Inc. to Initiate the inspection and revalidation r(.•)i
any of the components installed as of the above noted date,this certificate shall be process. Mae will be(charged for this service. ]
0 I • _ •
z , 4, , .4:ti• •-. .•ii Mil:r.• rrvl�Sr}3,1'•i4.i=v---- Y%;:4,'-la• �4F"��c,,,:=+ C �, ,,rw +\:4'ar��:�•::5� S y `riA%' -4--\re+(4 :E-�
,r`;w �Y: r is..v... r ;.\v,..�: < x- �S S �'�•t '�-� ,J�st �S�y,.`.rr.ori`_e/A r ✓r,y✓•,.y', eri`✓�er. �. rr ;,� y.J er.
.•�:.:1��%~��✓�;l✓%����✓.�!�vv:�;ei:>`i,� .�7��Tji✓1-����J�✓�.1<`✓=�'.%�.: ,. ._.v L•.�•.!n•,..•.{.. t.•�.�.*,�'v ti .•,.`_n {v<�-t..�-.v
1
•
•
I
'
t WO(c2,\\-7_33 \--1
Envelope Leakage
Test
Testing Company Technician
Name:KENNA CONSTRUCTION Name:DEREK KENNA
Address: Credentials:BPI#5060817
Phone:(518)477-3978 Email:DEREK.KENNA@INSTALLED.NET
Building information
Customer Information
Project ID:
Address:28 N.Church Ln. Name:TechEast Construction
Queensbury,NY12804 Address:20 Emerick Rd.Lbudonvillef NY 12211.
Phone:(518)344-7892
Email:Techeastconstruction@yahoo.com
Ls ) Fail Test Characteristics
TeSt Results Indoor Temp:75 t
•
Measured Leakage:3.0 ACH50 Outdoor Temp:82
Leakage Target:<3 ACH50 Humidity:66%
;Compliance with Leakage Time Average Period'
Target: Test Date:JULY 16,2018
Test ID:
Measured CFM50:1350
Building Volume:27,040
Test Equipment
Flow Device: I •
ENERGY CONSERVATORY
:MODEL 3
Pressure Gauge:DG700 Serial Numbe • 3450 Calibration Date:8115/2016
•
Technician Signature: h
• •
•
1