RC-000591-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000591-2017 Date Issued: Tuesday, October 30, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000591-2017
has been completed.
Tax Map Number: 308.7-1-25
Location: 4 WESTBERRY WAY
Owner: DDDJ Enterprises
Applicant: DDDJ Enterprises
This structure may be occupied as a: Single Family Dwelling w/FP 1546 s.f.
3-car Garage 865 s.f. By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the r
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
` -. TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000591-2017
Tax Map No: 308.7-1-25
Permission is hereby granted to: David Howard
For property located at: 4 WESTBERRY WAY
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tyne of Construction
Owner Name: DDDJ Enterprises Single Family-New $170,000.00
Owner Address: 470 WEST MOUNTAIN RD Total Value $170,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
DDDJ Enterprises
470 WEST MOUNTAIN RD
Queensbury,NY 12804
Plans&Specifications
Single Family Dwelling w/FP 1546 s.f.
3-car Garage 865 s.f.
$1,338.95 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,October 22,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbua before the exp' tion date.)
Dated at the Town of ueensb kda , r 20,2017
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
--- I— a— —.——- vim«.. . a . aa ', V11 l�iG uJG kinly
Late: _1 54�r1= -00 17 Permit No. P_-S-1.I' zot'4-
Tax Map Ill „ 1— I — ZC7 Permit Fee �98b. S ri�0 i
Zone _ Historic? _Yes INO Rec Fee "$=_'O — ._2zt_..1
Subdivision Name �rt�
4: &. r( _Lot# Site Plan#
Subdivision#
Project Location - A'Mr__: .( yJ
TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family, multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit fee(s).
Primary Owner(s) DQDJ
Address Al u Webfi nA-rA V-6A0 I �''� IV� 1200+
Phone/Email rJ- I _ 014 V%p W t-d 35 ZOco 9'LP h Co.CO YY)
Applicant
Address
Phone/Email
Contractor IG-4Y)r)C r�7 0U3lJr':_?__
Address
Phone/Email
tib p �-
Contact Person for Building &Codes Compliance: _PU G N5M A (,L A044. Phone '548-741-02*
TYPE OF CONSTRUCTION
,/Check all that apply New Addition Alteration I'floor sf 2”d floor sf Total sf Height
Single Family I � aJrJ 1 (40tt
t 1 !►�
Two-Family
Multi-Family
(#of units )
Townhouse
Business Office SEP t 2017 [UJ
Retail-Mercantile ®WN OF QU ENSBURY
Factory-Industrial
Attached Garage
I 11
(1, 2,04+)
Other
Town of Queensbury Building&Codes Principal Structure Application revised January 2016
If commercial or industrial please indicate name of business p,
Proposed use of building or addition
Source of Heat (circle one) Gas Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances & Chimneys
Are there structures not shown on plot plan? Nay
Are there easements on the property? KtAp LW
Site Information:
a. Dimensions or acreage of lot 11�9I Sr- 0,lbo
b. Is this a corner lot? Yes No
c. Will the grade be changed as a result of construction Yes No
d. Public water or Private well (circle one) 4u Private
e. Sewer or Private Septic System(circle one) Sewer neat
Value of all work to be performed(labor or materials) $ 110,000
DECLARATION.
1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If work is not complete by the I year expiration date the.permit may be renewed, subject to fees and
department approval.
3. I certify that the application, plans and supporting materials are a true and complete statement /
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes, local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above: lAa-
nw
PRINT NAME: tAA u, — F
SIGNATURE: DATE:
For office use only
Operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
SEPTIC DISPOSAL APPLICATION Office Use Only
Received
DATE: Qj n Tax Map 1D
TAX MAP ID: _ •'1 Zej Permit No.
Permit Fee
ZONE:
APPLICANT PHONE/E-MAIL rJ�' l 071T
ADDRESS 410 (��T �`EJT q M W"rot
INSTALLER 1 �^�� � � PL46 I PHONE/E-MAIL
BUILDER I"'y f'�T'p�,/) IV
OWNER
ADDRESS L� A U .lSBut�`{ 12$D
CONTACT PERSON FOR BUILDING&CODE COMPLIANICE: ,•IJANA, CA45" tali
PHONE/E-MAIL 1-6 ra4l� �• ('p,m
RESIDENCE INFORMATION
Year Built #of bedrooms X gallons per bedroom =total Daily flow
1980 or older Garbage grinder installed Yes No
1981-1991 Spa or Hot Tub installed Yes _No
1992-Present 1115 1 1 p O
PARCEL INFORMATION
Topography Flat rolling Steep slope %Slope
Soil Nature Sand Loam Clay Other
Groundwater At what depth: elG tJZ 20("? IG14
Bedrock/Impervious material At what depth: t4Dr_
Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is_ft.)
Percolation Test Rate: '�—per minute per inch(test to be completed by licensed engineer/architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION
Tank size [Q0t7 gallons(min.size 1,000 gallons,add 250 gallons to si e a y'n a" fiot tub
System Absorption field with#2 stone Total length 150
Seepage Pit with#3 stone How many:
Alternative System Bed or other type: Ll
Holding Tank System Total required capaci TOWN ORQUEMSBU Y #of tanks
Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will
no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the
septic system layout on file—no exceptions.
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure
to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to
abide by these and all requirements of the Town of Queenssbbuury anitary Sewage Disposal Ordinance.
PRINT NAME: �i6'IN^I �'N ' ►( GjO�
SIGNATURE: XVDATE:
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Fuel Burning Appliance & Chimney Application Office Use only
ab Received
DATE: IS 699T= Tax Map Ill --
TAx MAP ID: ,1 — ( — ZGj Perin it No.
ZONE: Permit Fee
OWNER P\
l1t PHOlNE/E-MAIL
ADDRESS 410
I104a Ir -2* .Ccs
INSTALLER/ i� v PHONE/E-MAIL
BUILDER
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE:
PHONE/E-MAIL *Wt'UILDING ADDRESS
ROOM OF INSTALL: (,Lylt\& PLANNED INSTALL DATE:. 20 n
FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN&
STOVE FINAL INSPECTION ARE
FIREPLACE INSERT REQUIRED.
FIREPLACE,FACTORY BUILT* NOTE:
FIREPLACE,MASONRY
MANUFACTURER'S
FURNACE(GARAGE ONLY) INSTALLATION MANUAL
MUST BE AVAILABLE AT
TIME OF INSPECTION
*If factory built provide manufacturer name: �� _; Model #:
Listed by: Number:
CHIMNEY INFORMATION
Masonry** (check one) BLOCK BRICK STONE
Flue TIE le STEEL Size in inches
Material DOUBLE WALL —TRIPLE WALL INSULATED
** If non-masonry provide manufacturer name: ; Model#:
DECLARATION: Construction/installation must conform to NYS Fir, It
and/or
manufacturer requirements. The applicant or owner agrees to comply all ,a��pplic b w i ances,
regulations,and all conditions that are part of these requirements and als lo�'sp� o o a emises
to perform required inspections.
TOWN OF QUEENSBURY
CO
I HAVE READ AND AGREE TO THE ABOVE: BUILDING& DES•--• - - -"'"
PRINT NAME: O.N� �. Ol I Tuor
SIGNATURE: /V
DATE: f 2x17
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
INSPECTION WORKSHEET (007702-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
RC-000591-2017Permit
Case Number:Case Module:
Tue Oct 30, 2018Passed
Inspection Date:Inspection Status:
Charles DyerResidential Final Inspection
Inspector:Inspection Type:
4 WESTBERRY WAY308.7-1-25
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantDDDJ Enterprises
Primary OwnerDDDJ Enterprises
ArchitectRucinski-Hall Architecture
ContractorDDDJ Enterprises
Granted PermissionHoward, David
Checklist ItemPassedComments
General CommentsNO
4 inch Building Number Address visible from roadYES
Chimney Height / B Vent / Direct Vent LocationYES
Chimney Rain Cap InstalledYES
Fresh Air IntakeYES
Fresh air supply 3' from gradeYES
3" Plumbing Vent through roof minimum 18 inchYES
Oct 30, 2018Page (1)
INSPECTION WORKSHEET (007702-2018)
Checklist ItemPassedComments
Outside Spigots have Air GapYESProvide air gap on exterior spigots
10/30/18
Roof Complete / Exterior Finish CompleteYES
Platform at all exterior doorsYESProvide 3'x3' platform at sliding glass door , more than 2
risers
Verified guard at door
Handrail 4 or more risersYES
Window guards req:<2' above floor/6' aboveYESProvide window guards, sill is less than 24" from floor
grade - quick release installedVerified
Guard at deck, porches 36" or moreNO
Handrail Termination at Newell Post or WallYES
Interior/Exterior Railings 34 to 38NO
Wood deck: 2'+ from grade dia bracing required -NO
H/C ramp compliant
4+ Deck Joist Ledger Connections-24" FromNO
Ends
Deck Ledger-Bolted per CodeNO
Grade away from foundation 6 with 10 feetYES
6 clearance to sill plateYES
Oct 30, 2018Page (2)
INSPECTION WORKSHEET (007702-2018)
Checklist ItemPassedComments
Gas Shut-off Exposed & Regulator (18) AboveYES
Grade
HVAC Vent Terminal 10' from Lot Line &YES
Openings
Dryer Duct Max Length 35', Labeled Over 35'NO
Interior privacy/trim/doors/main entrance 36YES
Bathroom / Kitchen WatertightYES
Low flow toilet 1.3 gal/flushing cycle -YES
showerhead/faucet
Smoke Detectors: Carbon MonoxideYES
Smoke Detectors 3' from Kitchens & Baths R314YES
Every level, Every bedroomYES
Outside every bedroom areaYES
Inter ConnectedYES
Battery backup: _____YES
Attic Access 22 x 30 minimumYES
Attic Access Insulation = Attic R- ValueYES
Attic Access GasketedYES
Oct 30, 2018Page (3)
INSPECTION WORKSHEET (007702-2018)
Checklist ItemPassedComments
Bathroom Fans, if no windowYES
Plumbing fixturesYES
Backflow Preventors where requiredYES
Foundation insulation to floorYES
Energy Sticker on Elec. Panel:R-Val. & HeatingYESProvide energy sticker, last page on REScheck has format of
Syswhat's required, then place on furnace or electrical panel
door
Duct work sealed properlyYES
Intake OpeningsYES
Blower Door Test CertificationYES
HRV or ERV Installed per Bedroom RequirementsYES
Floor truss, draft stop- fin base 1,000 sq. ft.NO
Emergency egress below gradeYES
Furnace shut-off w/in 30 ft. or w/in line of siteYES
Furnace Hot Water Heater operatingYES
Relief Valve ,Heat Trap/Water Temp 110 deg orNOProvide relief valve on water heater
less
Oct 30, 2018Page (4)
INSPECTION WORKSHEET (007702-2018)
Checklist ItemPassedComments
Encl. Stairs Sheetrock Underside minimum ½NO
Gypsum
1/2" Gypsum or House Wall and GableYES
5/8" Type X with Living Space AboveNO
20 Minute Fire Door/Self-Closing HardwareYES
Seals on Garage Doors, esp. WoodYES
Basement stairs closed rise greater than 4 inchesYES
Basement Egress: 5s.f. window w/sill or BilcoYES
door
Garage Floor PitchedYES
Gas Log In Sealed or Glass EnclosureYES
Fin Elect; Energy Saving Light Bulbs 50 PercentYES
Final Survey Plot PlanNO
Arc Fault Breaker Habitable SpacesNO
Flex Gas Pipe BondingYES
As Built Septic SystemNO
Truss ID Signage Installed at Electrical MeterYES
Oct 30, 2018Page (5)
INSPECTION WORKSHEET (007702-2018)
Checklist ItemPassedComments
OK to Issue Temporary C/ONO
OK to Issue C/OYES
Dyer, Charles (Inspector)
Oct 30, 2018Page (6)
REVIEWED FOR
ENERGY CODE COMPLIANCE
REScheck Software Version 4.6.3
Compliance Certificate
LO
N CO
Project New Model Home 00
Energy Code: 2015 IECC
Location: Glens Falls, New York SEP i V
Construction Type: Single-family 201?
Project Type: New Construction N 47
Orientation: Bldg. faces 135 deg. from North
I QF�UEENSBURY �'' N
Conditioned Floor Area: 1,489 ft2 LDING & CODES i
Glazing Area 11% Q, �
Climate Zone: 6 (7635 HDD) (5 �+
Permit Date: N
4-0
N
LL
Permit Number: r W
I+
Construction Site: Owner/Agent: Designer/Contractor: Q
Lot 22 Westberry Lane David Howard Ethan Peter Hall p LL.
Queensbury, NY 12804 495 Luzerne Road Rucinski Hall Architecture M
Queensbury, NY 12804 134 Dix Ave
518-361-0714 Glens Falls, NY 12801
howard35_2000@yahoo.com 518-741-0268
ephall@nycap.rr.com
Compliance: Passes using UA trade-off
Compliance: 2.5%Better Than Code Maximum UA: 281 Your UA: 274 -- - -
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. F LE CO
1 _____-----
Envelope Assemblies
Gross Area Cavity Cont.
Perimeter
Ceiling 1: Raised or Energy Truss 1,489 49.0 0.0 0.020 30
Wall 1: Wood Frame, 16"o.c. 600 21.0 0.0 0.057 29
Orientation: Front
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 56 0.290 16
Orientation: Unspecified
Door 1: Glass 20 0.340 7
Orientation: Unspecified
Door 2: Solid 18 0.300 5
Orientation: Unspecified
Wall 2:Wood Frame, 16"o.c. 360 21.0 0.0 0.057 19
Orientation: Right side
Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 6 0.290 2
Orientation: Unspecified
Door 3: Solid 18 0.300 5
Orientation: Unspecified
Wall 3:Wood Frame, 16"o.c. 600 21.0 0.0 0.057 28
Orientation: Back
Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 65 0.290 19
Orientation: Unspecified
Door 4: Glass 40 0.340 14
Orientation: Unspecified
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 1 of 10
Gross Area Cavity Cont.
Perimeter
Wall 4:Wood Frame, 16"o.c. 360 21.0 0.0 0.057 20
Orientation: Left side
Window 4:Vinyl/Fiberglass Frame:Double Pane with Low-E 6 0.290 2
Orientation: Unspecified
Basement Wall 1: Solid Concrete or Masonry 534 0.0 15.0 0.043 23
Orientation: Front
Wall height: 8.9'
Depth below grade: 7.9'
Insulation depth: 8.5'
Basement Wall 2: Solid Concrete or Masonry 321 0.0 15.0 0.043 14
Orientation: Right side
Wall height: 8.9'
Depth below grade: 7.9'
Insulation depth: 8.5'
Basement Wall 3: Solid Concrete or Masonry 534 0.0 15.0 0.043 22
Orientation: Back
Wall height: 8.9'
Depth below grade: 7.9'
Insulation depth: 8.5'
Window 5:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.290 3
Orientation: Unspecified
Basement Wall 4: Solid Concrete or Masonry 321 0.0 15.0 0.043 13
Orientation: Left side
Wall height: 8.9'
Depth below grade: 7.9'
Insulation depth: 8.5'
Window 6:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.290 3
Orientation: Unspecified
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.3 and to comply with the mandatory requiremested ip a RE ck nspection Checklist.
Ethan Peter Hall-Architect ;i
Name-Title Si re Date
•'r , c
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 2 of 10
REScheck Software Version 4.6.3
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section i Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate []Does Not
[PR111 energy code compliance for the ❑Not Observable Location on plans/spec:A-
�, building envelope.Thermal 1
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for Location on plans/spec:A-
[PR311 lighting and mechanical systems. ❑Not Observable 1
V Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met.
403.7 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Location on plans/spec:A-
Manual J or other methods Btu/hr Btu/hr 1
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 13 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 3 of 10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO411 insulation R-value.Where interior R_ R- ❑Does Not table for values.
insulation is used,verification
430 ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions. ❑Not Observable Location on plans/spec: A-
1
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO611 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies Exception: Requirement is
[FO11]2 to protect exposed exterior ❑Does Not not applicable.
v, insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[FO12]2 controls installed. ❑Does Not not applicable.
., ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 4 of 10
Section Plans Verified Field Verified
& Req.ID# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR111 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR211
303.1.3 U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or Location on plans/spec: A-
d
taken from the default table. ❑Not Observable 1
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met.
[FR2311 installed per manufacturer's ❑Does Not
instructions. ❑Not Observable Location on plans/spec: A-
❑Not Applicable 1
402.4.3 Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies Exception: Requirement is
[FR16]2 sealed at housing/interior finish ❑Does Not not applicable.
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. [-]Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies Exception: Ducts located
[FR12]1 insulated >= R-8 where duct is ❑Does Not completely inside the
>= 3 inches in diameter and >_ ❑Not Observable building envelope.
R-6 where < 3 inches. Supply and
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable Location on plans/spec: A-
❑Not Applicable 1
403.4 HVAC piping conveying fluids R- R- ❑Complies Exception: Requirement is
[FR17]2 above 105°F or chilled fluids ❑Does Not not applicable.
below 55°F are insulated to>_R-
❑
3 Not Observable
El Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies Exception: Requirement is
[FR24]1 piping. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met.
[FR18]2 >_R-3. ❑Does Not
❑Not Observable Location on plans/spec: A-
❑Not Applicable 1
403.6 Automatic or gravity dampers are ❑Complies Requirement will be met.
[FR 1912 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable Location on plans/spec: A-
❑Not Applicable 1
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 5 of 10
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 6 of 10
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID 7
303.1 All installed insulation is labeled ❑Complies Requirement will be met.
[IN13]2 or the installed R-values ❑Does Not
provided. ❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood []Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). E] Steel E] Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies Requirement will be met.
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable Location on plans/spec:A-
❑Not Applicable 1
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 7 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ❑Not Observable
402.2.6
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every ❑Not Observable Location on plans/spec:A-
300 ft2.
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies Requirement will be met.
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that ❑Not Observable Location on plans/spec:A-
extends over insulation. 1
[]Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[F13]1 insulation >_R-value of the []Does Not
adjacent assembly. ❑Not Observable Location on plans/spec:A-
❑Not Applicable 1
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable Location on plans/spec: A-
1
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Requirement will be met.
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air []Not Observable Location on plans/spec:A-
handler @ 25 Pa. For rough-in 1
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met.
[F127]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total ❑Not Observable Location on plans/spec: A-
leakage measured with a 1
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met.
[FI24]1 by manufacturer at<=2%of ❑Does Not
design air flow. ❑Not Observable Location on plans/spec:A-
1
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies Requirement will be met.
[FI9]2 installed for control of primary []Does Not
heating and cooling systems and ❑Not Observable Location on plans/spec: A-
initially set by manufacturer to 1
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies Exception. Requirement is
[FI10]2 on heat pumps. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water []Complies Exception: Requirement is
[Fl11]2 systems have automatic or ❑Does Not not applicable.
accessible manual controls.
❑Not Observable
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 8 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system ❑Complies Requirement will be met.
[FI25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy ❑Not Observable Location on plans/spec:A-
and air flow limits.
❑ 1
Not Applicable
403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is
[FI26]2 through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is
[FI28]2 have a circulation pump.The ❑Does Not not applicable.
system return pipe is a dedicated ❑Not Observable
return pipe or a cold water supply
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not not applicable.
515.Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies Exception: Requirement is
[F130]2 have recirculation pumps that ❑Does Not not applicable.
pump water from a heated water
supply pipe back to the heated ❑Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F. _
403.5.4 Drain water heat recovery units ❑Complies Requirement will be met.
[F131]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side Location on plans/spec: A-
pressure loss of drain water heat ❑Not Observable 1
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies Requirement will be met.
[FI6]' fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. Location on plans/spec: A-
Does not apply to low-voltage ❑Not Observable 1
❑
lighting. Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
[F123]3 no continuous pilot light. ❑Does Not
t, Location on plans/spec: A-
❑Not Observable
- 1
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: Y:\Howard Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 9 of 10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[FI7]2 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies Requirement will be met.
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: New Model Home Report date: 09/18/17
Data filename: YAHoward Construction\Lot 22 Sherman Ave\Lot 22 Westberry Lane.rck Page 10 of 10
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.29
Door 0.34
&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
4 Wesfbarry WaY
HVAC Load Calculations
for
Rucinski Nall
RH' V"AC—*', K LOADS
p [: ,CEOdE
OCY
0 2 2V FILE COPY
TOWN OF QUEENSBURY
BUILDING&CODES
Prepared By:
Nick Abrunza
Appolo Heating
868 Burdeck St
Schenectady Ny 12306
Friday,September 29,2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
? SAp
vac-Residential&Light Corrrnercial 14VAC Loads - Elite Softy+are I;evelopment,Inc.
polo Heating Inc. 4 Westbarry Way
enectady NY 12306
� Pa e 5
Duct Size Preview
Room or Minimu Maximo Rough Design S Duct Duch Htg Cig Act, Duct
Source Veloci Veloci Facto L/10 Loss Velocity Lengt
Duct Name Q _ . -_._. , _�? Flow -.-FtowF)ow. Size__
System 1
Supply Runouts
Zone 1
1-Basement Built-In 450 750 0.01 0.1 663.1 149;. .. 116. 116 2--4
2-Bedroom 2 Built-In 450 750 0.01 0.1 501.4 59G'`i_ 98 98 1-6
3-Bath 1 Built-in 450 750 0.01 0.1 441.8 21! 39 39 1--4
4-Bedroom 1 Built-In 450 750 0.01 0.1 453.4 56t_ 89; 89 1-6
5-Kitchen/Dining Built-In 450 750 0.01 0.1 550.7 61 . 75. 75 1-
6-Living Built-In 450 750 0.01 0.1 670.1 81, ._117 117 2
7-Mud Room Built-In 450 750 0.01 0.1 372.6 24` 33' 33 1-4
8-Master Bedroom Built-in 450 750 0.01 0.1 668.7 58 : 117. 117 2-4
9-WIC Built-In 450 750 0.01 0.1 343.3 23`, 30, 30 1--4
10-Master Bath Built-in 450 750 0.01 0.1 489.8 25 43 43 1-4
Other Ducts in System 1
Supply Main Trunk Built-in 650 900 0.003 0.1 725.4 557:. .756; 758 10x1
Summary
System 1
Heating Flow: 557
Cooling Flow: 756
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\4 Westbarry Way.rh9 Friday, September 29, 2017, 5:07 PM
Rhvac-Residential&Light Cornmerciai HVAC Loads ,-.� Mite Software 6evaloprnent,Inc.
Appoto Heating Inc. 4 Westbarry Way
Schenectady NY 12306 Page 6
Total (ding Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
Anderson: Glazing-Anderson Windows, u-value 0.28, 137.4 2,656 0 1,953 1,953
SHGC 0.3
Pella Slider: Door-Slider 40.8 845 0 282 282
Fire Rated: Door-Fire Rated 21 246 0 82 82
12D-Osw: Wall-Frame, R-15 insulation in 2 x 4 stud 953.6 5,657 0 1,349 1,349
cavity, no board insulation, siding finish,wood studs
12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1616.2 7,250 0 1,291 1,291
cavity, no board insulation, siding finish,wood studs
168-50: Roof/Ceiling-Under Attic with Insulation on Attic 1537.4 2,121 0 1,445 1,445
Floor(also use for knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation
21A-24: Floor-Basement, Concrete slab, any thickness, 2 1490 2,570 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24'wide
19A-Ocp: Floor-Over enclosed crawl space, No insulation 1315.5 10,060 0 1,749 1,749
on exposed walls, sealed or vented space, passive,
no floor insulation, carpet or hardwood
19A-Otp: Floor-Over enclosed crawl space, No insulation 221.9 1,834 0 318 318
on exposed walls, sealed or vented space, passive,
no floor insulation, tile or vinyl
Subtotals for structure: 33,239 0 8,469 8,469
People: 4 1,200 1,600 2,800
Equipment: 0 0 0
Lighting: 1570 5,354 5,354
Ductwork: 0 0 0 0
Infiltration:Winter CFM: 121, Summer CFM:65 9,053 1,300 844 2,144
Ventilation: Winter CFM: 0, Summer CFM:0 0 0 0 0
AED Excursion: _ 0 _ 0 131 13_1
Total Building Load Totals: 42,292 2,500 16,398 18,898
Check Figures
Total Building Supply CFM: 756 CFM Per Square€t.: 0.250
Square ft. of Room Area: 3,027 Square ft. Per Ton: 1,922
Volume (ft'): 25,911
Building Loads
Total Heating Required Including Ventilation Air: 42,292 Btuh 42.292 MBH
Total Sensible Gain: 16,398 Btuh 87 %
Total Latent Gain: 2,500 Btuh 13 %
Total Cooling Required Including Ventilation Air: 18,898 Btuh 1.57 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:1Userslnicka\DocumentslEliite SoftwarelRhvac 9 Projectsl4 Westbarry Way.rh9 Friday, September 29, 2017, 5:07 PM
FAppolo
c Residential&Light Commercial HVAC toads V Elite Software Development,Inc.
Heating lnc. 4 Westbarry Way
ectad ,NY 12306 Page 18
System 7 Room Loam Summary
Htg Min Run Run Clg Cig Miry Act
Room Area Sens Htg Duct Duct Sens Lai CIg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Basement 1,490 11,345 149 2-4 663 2,512 448 116 116
2 Bedroom 2 168 4,496 59 1-6 501 2,137 454 98 98
3 Bath 1 90 1,592 21 1-4 442 837 38 39 39
4 Bedroom 1 214 4,283 56 1-6 453 1,932 415 89 89
5 Kitchen/Dining 253 4,658 61 1-5 551 1,630 98 75 75
6 Living 396 6,134 81 2-4 670 2,538 128 117 117
7 Mud Room 59 1,806 24 1-4 373 706 66 33 33
B Master Bedroom 227 4,369 58 2-4 668 2,530 714 117 117
9 WIC 58 1,736 23 1-4 343 650 74 30 30
10 Master Bath _ _ 73 1,873 25 _ 1„_4 490 _ 928 65 _43 43
System 1 total 3,027 y 42,292 557 16098 2,500 756 _756
System 1 Main Trunk Size: 10x15 in.
Velocity: 725 €t./min
Loss per 100 ft.: 0.093 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons Slit Btuh Btuh Btuh
Net Required: 1.57 87%113% 16,398 2,500 18,898
Actual: 1.87 75%125% 16,800 5,600 22,400
Equipment Data
Heating System Coolinq_System
Type: Natural Gas Furnace Standard Air Conditioner
Model: ML195UH070XP366* 13ACXN024-23OA23
Indoor Model: C35-24A*+TDR
Brand: MERIT 90 LENNOX
Description: Natural Gas or Propane Furnace
Efficiency: 95 AFUE 13 SEER
Sound: 0 0
Capacity: 64,000 Btuh 22,400 Btuh
Sensible Capacity: nla 16,800 Btuh
Latent Capacity: n/a 5,600 Btuh
AHRI Reference No.: n/a 9153216
C:\Users\nicks\Documents\Elite Software\Rhvac 9 Projects\4 Westbarry Way.rh9 Friday, September 29, 2017, 5:07 PM
AIR SEALING AND BLOWER. DOOF
TESTING SERVICES
RESIDENTIAL ONLY
LT Building Seivices, LLC North East Spray Loam
Jim Telfer, Owner 7 Rocky Ridge
518-925-7715 Warrensburg, NY 12885
j Itbu i Id i ngservicesOa gmai i.com 518-350-2491 or 518-623-7010
Thermal Associates Grainy Consulting, LLC
21 Thomson Ave. 69 Hayden Pt. Loop
Glens Falls, NY 12801 Diamond Point, NY 12824
518-798-5500 518-221 -3240
Stonehenge Associates
27 Cohoes Road
FILE COPY
Watervliet, NY 12189
518-874-1604
Town of Queensbury Building&Code Enforcement Revised March 2017
} q-
\ GEN ER AaL NOTESLn
m
/r INFORMATION 'SHOWN ION THIS DRAWING IS TAKEN FROIv1 �
\ A SURVEY DRAWING PREPARED BY VAN DUSEN & STEVES v
0)
SEPTIC SYSTEM NOTES: TILE FIELD TO BE DESIGNED IN
ACCORDANCE WITH SUBDIVISION REQUIREMENTS AS INDICATED ON Q
\ DWG. S'7 PREPARED BY NACE ENGINEERING P.C. X
2 REVISED GRADING & SEPTIC. 18 OCT 2017 .
\
LEGEND 1 REVISED GRADING 13 OCT 2017Ln
m
0 REVISED SEPTIC 3 OCT 2017
\ ' — - - - - - - --- PROPERTY LINE No. DESCRIPTION DATE o
----- ------------- REVISIONS
PROPERTY LINE SETBACKS REVI
\\ ' ----------330---------- EXISTING CONTOURS 00
330 NEW CONTOURS � o
N r C31
o ,
E — —E E UNDERGROUND ELECTRIC SERVICE Lj
� F Q
SS $s ---SS \SS SANITARY SEWER v z
` � a � z
\ / w —vv WATER SERVICE
/ e ! L
r in
/ e ESP EDGE OF PAVEMENT Q o
-GAS=-GAS GAS\GAS- UNDERGROUND GAJ SERVICE - O I,4
/
O
J
/
PERMIT ., < O Z Q
n r Q
\ I HAVE PERSONALLY ivicASUitEf_
;H-1: L,;'. \\ \ E
FROM THE PROPERTY P ?''?`_S -f
° F-1 V
SULTS Qo �
/
PROP c r I , �
ED vTE�I.?CT�drv,_ �,' ;:i? :>i...,, a� s°o r`�. Q � z o va
PES
- tie ' TAKEN FROM DWG. S-7= OF SUBDIVISION PLANS
LA � TRE
SIG URE - `� \` I FROM MACE — Q o ° cx w
I! ENGINEERING P.C. 3 a z } o
v �, o
Z .2qua ao�a � � w u
0-
LOT
LOT NU�98ER ! DEPTH STABILIZED RESULT
in Inches per one inch drop ° cr X n
7 fy w c9 5 L'w a
! 2� 24 1 25
C - LQT PLAN W ,' - - o
\/ I HAVE SEEN OR OBSERVED ALL OBJECTS
SUCH AS HOUSES, WELLS, TREES, FENCES, ETC f e / t
^1 \ / TEST PIT DATA
WORK IS TO BE AS SHOWN & "
I / r ` \\ _.
SHOWN ON THIS DOCUMENT.I HAVE PERSONALLY -�
/ h1EAe''�r THE�'o'1NCF cl '0�'T-,ONTHIS DIAGRAM. rd / s\ 1\ \`\ `\ ! TAKEN FROM DWG. S-7, OF SUBDIVISION PLANS FROM MACE NOTED AND IN ACCORDANCE
\ - WITH MANUFACTURER'S
ENGINEERING P.C.
\ \ RECOMMENDATIONS, TRADE
s NATURE ' 10ASSOCIATION PUBLISHED
DATE
9 TP Lot 22
E�tl`�IING EARTHEN \ / RECOMMENDATIONS AND
0- 9 Inches, topsoil
BERM TO REMAIN ! 9, -25 Inches, loarrsy fine sand GENERALLY ACCEPTED LOCAL
( i i /� /' :•♦ ` D`, `\ \\ 25-76 Inches, fine and medium sands CONSTRUCTION INDUSTRY
� ' PRACTICES,
\ °iry / f/ \ .•ate w'r
6
4 SEPTI S YS TE VLSI
•P 1l
DESIGN FLOW - NEW 3 BEDROOM HOUSE WITH NEW STANDARD WATER
/ \ � / Via'. :-�:� f•':, 1,,,t \ f ! �
.,, ```•-. . / SAVING FIXTURE'S AT 110 d PER BEDROOM 33[3 d
SEPTIC TANK - 1,000 gal TANK REQUIRED (IN RESIDENCES WHERE A
GARBAGE DISPOSAL IS TO BE INSTALLED AN ADDITIONAL 250 gal. OF
/ �� /' �4\ \ ~\e `\\ !/\ / CAPACITY WILL BE PROVIDED IN THE SEPTIC TANK AND A GAS COLLECTION
LT \\ ~~ I1 \` ! ; BAFFLE AND A DUAL COMPARTMENT TANK OR TWO TANKS IN SERIES
SOg ` / \ / '; ARE TO BE PROVIDED)
ori ® ,\\ \\ '\ 1 / /
' NS/ `\ NEW aE°��' ABSORPTION FIELD - 1 to 5 MIN. FERC. RATE r-- APPLICATION RATE
O SEWAGE j s r 1.2 coal/day/sq. ft. -°• 330.gpd DIVIDED BY 1.2 gal/day/sq, ft. =
DISPOSr1_ ITEC i r! 4 \ / ,/ 275 sq. ft. OF TRENCH REQ'D. AT 2' WIDTH PER LATERAL, USE 3 LATERALS
FIELD (:§ LATERAL0 /
/ s
( / \\. I' J' ,! !! AT - 0( sq ft. .OF APPLICATION AREA. cf�
_\ _ rJ \.
5 3
9 iD
/
0
i
ti. T •0
5
r
(
/ 4
NE`t�' DIST. BOX
LOCATION
V-llw
ct
r
FIN, FLOOR
EL. 101.25 � \ � T `>o ,� 3°;EW :SEPTIC
TANK LOCA'HON li X�
Al 2
FIN. GARAGE
/ FL, EL. 99.0'::t- / �� � , �.��- oma,
Sr6'q ' \..//• \\ !'' I ,I IIT f/ / �`/
NQP
ST' KPILE MATERIAL �. r /' I, r /
/ \\'\ e\�.`\�.`.\\ `w \ \� i - TOB REMOVED FROM SITE /'r i ,' i x E 9 E
// //,. -- ,a\ `\\•`\ \ r eo\a\\ \\ \\\ee\ e\o\ \ \`\ o\ , 1 \`w` ^.•,, . \\ � ! ij�'Am/// !,/ ' ! //' .- � .I - . - .. % \
,J -
!/ CT '11 7017L
FACAD\HOWARD\SHERMAN
FILE NAME
tv T000M1IVN OF C�UEENSSURY- AVE\LOT 22
,/ • ` ` `~ `\ `\ `\ `. \ 9 1 y ___--------f� /! i r �/ UN TY'®E\/ELOPII�ENT SCALE
\\ \ \ \\ _
THE SEAL BELOW IS AN ORIGINAL SEAL DRAWN BY
! ! / / / `\ •\ \\ `o `\ `\ `., ` D \ ` � �1 --_ _ ( `v\ I I AND IS IN RED INK. ONLY SEALS IN RED INK
A o J
SHALL BE CONSIDERED TRUE ORIGINALS
'JD \\ \` \\ \\ \\\ \ \\\\\\ \ �\ DRAWING TITLE
\ \ _ ... SITE
t
\ \ \ \ \ . \
r / / / r/ ! ! .o , \\ \, \ \ `\ St \ \o ~o •`\ ♦ \ \ ♦ \ ♦ \ \ \ \ \ , °� Yom, $
, rr ! / ~\o`\~\`o \ PLAN
J� \ \\\ \ \ \\ ~\ \\ ♦\ ♦ '. \ \\ \ \\ \\\ � /\ ', � + `' a Q��� off
DRAWING No.
/ / s / `, \ \ ` , \ ♦ °". \ \ \ {. s I / �' '*mow-a. 'y" i ^
I
i
I +
RUCINSKI HALL ARCHITECTURE .
Ronald Richard Rucinski �
Ethan Peter Hall 1\�GcN>
5
134 Dix Avenue G� ��
Glens Falls NY 12801 4-0 0
P
Voice 518 741 0268
Fax 518 741 0274
Email ephall@nycap.rr.com
Howard —Westberry Way
10 Oct 2018
John O'Brien —Town of Queensbury Building Department
742 Bay Road
Queensbury NY 12804
Re: Septic As-built
At the above referenced project location this office observed the installation of the new septic tank,
distribution box and sewage disposal field prior to back fill. These installations are acceptable to
this office. If there are any questions please contact our office to discuss.
Regards
/61,4 .
an Peter Hall
Architect
IF\II.ECEEIWEn
jL OCT 92018 {)
L.
.._ F.!`:S: ti' i. �.,i:El�;SBiURY
;, `. ;,ry '. _`VELOPMENT
in EL ELIVIE1 )
OCT 1 1 2018 j
I_
TOWN OF QUEENSBURY
COMMUNITY DEVELOPMENT
C:\!Ethan\!A1 Temporary Files\Floward\Westberry\Letter 10 Oct 2018.doc 1