Loading...
inspection 05282019INSPECTION WORKSHEET (SEP-003022-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000719-2017 Case Module:Permit Inspection Date:Tue May 28, 2019 Inspection Status:Passed Inspector:John O'Brien Inspection Type:Septic Job Address:Parcel Number:40 Sunnyside E Queensbury, NY 12804 290.6-1-62.2 Contact Type Company Name Name Primary Owner Callahan, Paul Applicant Callahan, Paul Architect Northern Design & Building Associates Granted Permission Callahan, Paul Checklist Item Passed Comments Building Inspector Notes YES 8/27/18 Septic System Partial Approval -Provide Engineer's As-Built and Final Approval 5/28/19 Septic System Approved -Received the engineer's as-built and final approval. Type of Water: Municipal / Well Water YES Well Absorbtion Fields: Total Length YES 300 ft Length of Each Trench YES 6@50 ft Depth of Trenches YES 24-30 inches Size of Stone YES #2 May 28, 2019 Page (1) INSPECTION WORKSHEET (SEP-003022-2019) Checklist Item Passed Comments Building to Tank YES 4 inch sch40 Tank to Distribution Box YES 4 inch sdr35 pvc Distribution box to Field / Pit YES 4 inch pvc to 4 inch pvc perforated Foundation to Tank YES 10 ft + Foundation to Absorption YES 21 ft Engineer Report and As-Built YES 8/27/18 Septic System Partial Approval -Provide Engineer's As-Built and Final Approval Location of system on property YES Rear left side System Use Status YES 8/27/18 Septic System Partial Approval -Provide Engineer's As-Built and Final Approval 5/28/19 Septic System Approved -Received the engineer's as-built and final approval. May 28, 2019 Page (2) O'Brien, John (Inspector)