inspection 05282019INSPECTION WORKSHEET (SEP-003022-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-000719-2017 Case Module:Permit
Inspection Date:Tue May 28, 2019 Inspection Status:Passed
Inspector:John O'Brien Inspection Type:Septic
Job Address:Parcel Number:40 Sunnyside E
Queensbury, NY 12804
290.6-1-62.2
Contact Type Company Name Name
Primary Owner Callahan, Paul
Applicant Callahan, Paul
Architect Northern Design & Building Associates
Granted Permission Callahan, Paul
Checklist Item Passed Comments
Building Inspector Notes YES 8/27/18 Septic System Partial Approval
-Provide Engineer's As-Built and Final Approval
5/28/19 Septic System Approved
-Received the engineer's as-built and final approval.
Type of Water: Municipal / Well Water YES Well
Absorbtion Fields: Total Length YES 300 ft
Length of Each Trench YES 6@50 ft
Depth of Trenches YES 24-30 inches
Size of Stone YES #2
May 28, 2019 Page (1)
INSPECTION WORKSHEET (SEP-003022-2019)
Checklist Item Passed Comments
Building to Tank YES 4 inch sch40
Tank to Distribution Box YES 4 inch sdr35 pvc
Distribution box to Field / Pit YES 4 inch pvc to 4 inch pvc perforated
Foundation to Tank YES 10 ft +
Foundation to Absorption YES 21 ft
Engineer Report and As-Built YES 8/27/18 Septic System Partial Approval
-Provide Engineer's As-Built and Final Approval
Location of system on property YES Rear left side
System Use Status YES 8/27/18 Septic System Partial Approval
-Provide Engineer's As-Built and Final Approval
5/28/19 Septic System Approved
-Received the engineer's as-built and final approval.
May 28, 2019 Page (2)
O'Brien, John (Inspector)