Loading...
RC-000639-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000639-2017 Date Issued: Monday, February 26, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000639-2017 has been completed. Tax Map Number: 308.12-1-31 Location: 103 BURNT HILLS DR Owner: Michaels Group Homes, LLC Applicant: Michaels Group Homes, LLC This structure may be occupied as a: Single Family Dwelling w/FP 1715 s.f. Garage 515 s.f. By Order of Town Board LARIC Development, Lot 31 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000639-2017 Tax Map No: 308.12-1-31 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 103 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tyne of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $300,000.00 Owner Address: 1 Marions Way Total Value $300,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marions Way Mechanicville,NY 12118 Plans&Specifications Single Family Dwelling w/FP 1715 s.f. Garage 515 s.f. LARIC Development,Lot 31 $1,320.25 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,October 22,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Qnsbury; FrayOtfor 7 SIGNED BY: he Town of Queensbury. Director of Building&Code Enforcement PRDiCIPAL STRU,CTLME APPLICATION Office Use Only ` Bate: t� [o 1-1 1 11 Permit No. Qs;,' (03 • ?o�`} Tax Map ID Permit Fee T 4�o Zone Historic? _Yes No I Rec Fee Y-21 Subdivision Name QuwxT Mbcta l-A%-+e) Lot# Site Pian# Subdivision m Project Location kO--S QAr40ot- 4 1LLs TOWN 8D.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Address i , Jk4%.e 1711S Phone/Email �?z Applicant ., nD Address na 20J7 Phone/Email Contractor BUILDING$ NSBURY I CODES Address ' Phone/Email Contact Person for Building&Codes Compliance: -101*4",r •314 4- TYPE TYPE OF CONSTRUCTION k ✓Check all that apply New Addition Alteration I 11,floor sf 21 floor sf Total sf £ex,�ikt i Single Family Two-Family � k ' I t Multi-Family I lhE of units f Townhouse I I Business Office j ! I C Retail-Mercantile i I IFactory-Industrial Attached Garage I � I I (1,C)3, 4+) 'l E I 'S►"S f1- i i I Other 17 i Town of Queensbury Building&Codes Principal Structure Application revised Januari 241-6 w j If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) a, Cil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? N�p Site Information: a. Dimensions or acreage of lot b. Is this a corner lot? Yes _&No c. Will the grade be changed as a result of construction Yes VC No d. Public water or Private well(circle one) QublicD Private e. Sewer or Private Septic System (circle one) Sewer rivate Value of all work to be performed(labor or materials) $ 3 oor,o oa — DECLARA T10i . 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement I description of the work proposed, that all work will be performed in accordance with the INYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: 213 PRENT NAIVIE: o L C' DATE: /0//i SIGNATURE: r DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy:,unit Special Conditions Town QPQueensbury Building&Codes Principal Structure application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use only i Received DATE: _�O So I 1 Tax Map ID TAx MAP ID: Permit No. ZONE: Permit Fee i 41ViW'ER i` #i i9c• �' �)� ?-�Uy4i ,L� 1{ PHONE/E-MAIL 51j .ms' s C1 )1 DRESS INSTALLER/ Fs 0c �.j t! �-�'A PP4\vPHONE/E-MAIL BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: �1 . ►-C�t_A<<3C-lam PRONE/E-MAIL �j8� - 8�� • ?14q BUILDING ADDRESS ld3 ROOM OF INSTALL: q Sze � +--bLtLk PLANNED INSTALL DATE: `tTZ-.kD FUEL BURNING APPLIANCE INFORMATION W OOD COAL PELLET E GAS flIL NOTE: ROUGE-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT i REC�t IREI). I FIREPLACE,FACTORY BUILT* A ! NOTE: ' FL}2EPLACE,MASONRY MANUFACTURER'S 4 FURNACE(GARAGE ONLY) { INSTALLATION MANUAL XUST BE AVAILABLE AT { { i ! TIME OF INSPECTION =*Ifory built provide manufacturer name: 1-1� -ti-4La ; ;Model#: SL.- '7ISO by: 0.1— Number: U L-150-I12> CHIMNEY INFORMATION Masonry* (check one) ; BLOCK BRICK STONE Flue { TIE STEEL Size in inches I Material DOUBLE WALL �TRIPLE WALL NSULATED ** If non-masonry provide manufacturer name: ; Model #: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions Haat are part of these requirements and also will allow inspector's to eater premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRII`dT'4iA2r1E; Id DATE: SICNATUIIRE: DATE: Taex^i of Queensbury Building cic Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only � i Received DATE: 4- 11"1 Tax Map ID TAX MAP ID: Permit No. ZONE: Permit Fee APPLICANT 1%-A tCA-i b.`1C_ C,ZCk" 4-tc3 k---S, L—C PHONE/E-MAIL ADDRESS 1 "bJXt®taS L AOe lJtc�-1-£ tttvtl.t,c", I�tY 1Zti@� INSTALLER/ C-14 b� FS�1�N!1��9 eltCANI A�'T%KLC, � PHONE/E-MAIL 4-7 BUILDER 01V iER M1t�4-IAs0.� (yTtCae.t� HG �S L C Sad .CbbCi ci ADDRESSE:j tui 1aL� 4- ILLS f CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: 'T-CN'--e f PRONE/E-MAIL tB67 .314 4- RESIDENCE RESIDENCE LN-FORMATION Year Built #of bedrooms j X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed _Yes >c No 1981-1991 ` Spa or Hot Tub installed Yes"*K No 1992-Present 3 i 110 330 — — i PARCEL INFORMATION i r Topography Sc FIat rolling Steep slope %Slope Soil Nature X Sand Loam CIay Other j Groundwater ( At what depth: I Bedrock/Impervious material At what depth: __(j��. Domestic Sxlater Supply ( K Municipal Well(if well,water supply from any septic system absorption is fL_ 1 Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEIM FOR NEW CONSTRUC'T'ION ! Tank size gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub i System Absorption field with 42 stone Total length S'a ft.;Each Trench Spc� j Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: _ Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2;We wiII no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINTNAME: C..4S61�0 DATE: C>A / 7 SIGNATURE: 14 DATE: Town of Queensbury Buil�gg&Codes Principal Structure Application Revised January 20 i 6 i Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Horne: 513-745-0929 Phone: 518-761-8211 Fax; 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PIi RTMIT Date: lc7' to Applicant Name: i +��. �-r�� -o .► L Telephone No.: '5+v Address to be Inspected lu? +-k tl_S -t5uy:_, Return Address: Applicant crust show exact Iocation and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) SIight Swale ( ) Deep Swale ( ) Level with the road { ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( } 36" Preliminary inspection completed by: Date; Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: C ) Final Approval { } Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&C-odes Principal'Structure Application Revised January 2016 f Wind ...PYK-Selml tile Calculation Sheet Joh Site Address: Date: �--. Owner: MlC.N1LS _. _._........._............_..._.__................_... _�u -'Mtst.t � Application No.: Window#or letter on plan -- -- Manta£ Nance - Model/Type C.nit or Block# C:'e11 size Rough Opening Width Rough Opening Height .._—___..........__.._..__-_.._-- Sq. lit. Vent Sq. Ft. Egress/Clear Opening Clear Opening-width in inches Clear Opening-Height in inches Special Hardware or instruction l IG H-17'\i��f�1 lI "f�.ci Gc�^+� =-C.JN "b U -Ax_) JI),4v+OW c ���s�JL - 1 iG E !1° i �0/�•-i l O► 1 Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 REScheck Software Version 4.6.2 ,. cl�(J wo LO Compliance Certificate M J N J ch ca);),� N Project The Troelstra Residence V J cu Energy Code: 2015 IECC "-: � Location: Warren County, New York 0 l� Y O Construction Type: Single-family (lf��' fIL�SOWE C Project Type: New Construction D L Conditioned Floor Area: 1,775 ft2 T Glazing Area 16% u OC I 2017 r C Climate Zone: 6 (8499 HDD) 04 T L m 3 Permit Date: 2 October, 2017 TOWN OF QUBENSBURY Permit Number: BUILDING&1--r- 100 U CIO ILL M o U) Construction Site: Owner/Agent: Designer/Contractor: 103 Burnt Hills Drive Michaels Group Homes, LLC Queensbury, NY 1 Marions Way Mechanicville, NY 12118 Compliance: Passes using UA trade-off Compliance: 4.8%Better Than Code Maximum UA: 289 Your UA: 275 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Foundation Wall: Solid Concrete or Masonry 1,497 0.0 19.0 0.039 58 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' 1x 5030 Sliding Windows: Vinyl Frame:Double Pane with Low-E 15 0.300 5 2x Std. Basement Window: Vinyl Frame:Double Pane with Low-E 4 0.300 1 1st Floor Walls: Wood Frame, 24" o .c. 1,773 21.0 0.0 0.056 83 Foyer#1: Solid 21 0.170 4 2x Home Office (AV): Vinyl Frame:Double Pane with Low-E 33 0.300 10 1x Main Bath (AV):Vinyl Frame:Double Pane with Low-E 16 0.300 5 1x Bed 2 (AV): Vinyl Frame:Double Pane with Low-E 16 0.300 5 2x Master Bed (AV): Vinyl Frame:Double Pane with Low-E 33 0.300 10 1x Master Bath (AL): Vinyl Frame:Double Pane with Low-E 8 0.300 2 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9 1x Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8 #7 Dining: Glass 40 0.300 12 2x Dining (C): Vinyl Frame:Double Pane with Low-E 21 0.300 6 1x Dining (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 1 of10 Gross Area Cavity Cont. Assembly or U-Factor UA rl Pe meter Mud #20: Solid 19 0.170 3 Ceiling: Raised or Energy Truss 1,775 38.0 0.0 0.025 44 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4..6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. .` wi Name-Title I Signature Date Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Reci.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PRM energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on []Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate []Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate ' compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not I[PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable E Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Compties? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R- R- ❑Does Not table for values. insulation is used, verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F0511 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F0611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in, below grade. []Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not ❑Not Observable I ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 4 of 10 i Section Plans Verified Field Verified # Framing/Rough-In Inspection value Value Complies? Comments/Assumptions & Req.ID L_ 1402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 1402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing LI-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products T ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable " ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not U0 AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR1612 sealed at housing/interior finish ❑Does Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 5 of 10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 6 of 10 Section LPlans Verified Field Verified # Insulation Inspection Value " Value Complies? Comments/Assumptions & Req.ID 1303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not 9provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood []Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior,the exterior insulation ❑ Mass ❑ Mass ❑Not Observable requirement applies(FR10). E] Steel E] Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 7 of10 Section ! Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, •;402.2.6 ❑ Steel ❑ Steel [-]Not Observable [Fll]1 ❑Not Applicable X303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every ❑Not Observable 300 ft2. ❑Not Applicable I _ 1402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 1402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI411 cfm/100 ft2 across the system orft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F12711 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of []Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Flg]2 installed for control of primary ❑Does Not heating and cooling systems and I initially set by manufacturer to [:]Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies I [Fill]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 8 of 10 Section Plans Verified FieldVerified # 1 Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID i 403.6.1 All mechanical ventilation system ❑Complies [F]25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. '❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems []Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and - no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated [:]Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. j403.5.4 Drain water heat recovery units ❑Complies I[F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies (FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not b ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID _ 401.3 Compliance certificate posted. ❑Complies I[FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies (FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Troelstra Residence Report date: 10/04/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\103 Burnt Hills Drive.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments i r � O N � 103 Burnt Hills Dr M J to HVAC Load Calculations c N O d J N for V ECD O N The Michaels Group _ N C.0 LO 0 — M }, VL N C LL = m 3 CM Mr2C) LL () f!t! .i. wi l 1 w i � ,Hx jVV, � R$SIDENWnAL, 4 g HVAC L,oAO i i PDEC EOWE OCT 11 2017 TOWN OF QUEENSBURY BUILDING&CODES Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Friday, October 06, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. ,Cxhvac-R,psidential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 103 Burnt Hills Dr Schenectady,NY 12306 Page 2 [Pro ect Report General Project Information Project Title: 103 Burnt Hills Dr Designed By: The Michaels Group Project Date: Thursday, October 5, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data Reference City: Schenectady, New York Building Orientation: Front door faces Southwest Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dr/ Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 962 CFM Per Square ft.: 0.259 Square ft. of Room Area: 3,714 Square ft. Per Ton: 1,907 Volume (ft3): 31,509 I Buildin Loads Total Heating Required Including Ventilation Air: 54,676 Btuh 54.676 MBH Total Sensible Gain: 20,886 Btuh 89 % Total Latent Gain: 2,483 Btuh 11 % Total Cooling Required Including Ventilation Air: 23,369 Btuh 1.95 Tons (Based On Sensible+ Latent) Notes --- i Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i:. w i L_ C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\103 Burnt Hills Dr.rh9 Friday, October 06, 2017, 9:00 AM khvac-,Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 103 Burnt Hills Dr Schenectady,NY 12306 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes I Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.280 AC/hr 0.150 AC/hr 147 CFM 79 CFM Infiltration Actual: 0.280 AC/hr 0.150 AC/hr Above Grade Volume: X 31.509 Cu.ft. X 31,509 Cu.ft. 8,823 Cu.ft./hr 4,726 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 147 CFM 79 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr(147 CFM), Construction: Average Summer Infiltration Specified: 0.150 AC/hr(79 CFM), Construction: Average C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\103 Burnt Hills Dr.rh9 Friday, October 06, 2017, 9:00 AM ,Rhvac-Residential&Light Commercial HVAC Loads = Elite Software Development,Inc. Appolo Heating Inc. ~"`}j 103 Burnt Hills Dr 1 Schenectady,NY 12306 Page 4 Load Preview Report f I { Min Min Sys Sys Sys� Duel Net on Sen La Nei Sen! CFM CFM CFMi CFM' CFM1 siz { Htg Clg Htg' Cig Act Scope To i (tori Area Gai Gair1 Gai Loss I i j Siz Building 1.95 1,907 3,7141 20,886 2,4831 23,369 54,676 720 962 720 962 9621 System 1 1.95 1,907 3,714 20,886 2,483 23,369 54,676 720 962 720 962 962 12x1 Zone 1 3,714 20,886 2,483 23.369 54,676 720 962 720 962 962 12x'1 1-Basement 1,772 2,820 591 3,411 15,483 204 130 204 130 130 2-5 2-Foyer 103 1,046 89 1,135 2,532 33 48 33 48 48 1-4 3-Home Office 161 1,561 55 1,616 2,959 39 72 39 72 72 1--5 4-Bath 1 95 942 52 994 2,019 27 43 27 43 43 1-4 &Bedroom 2 182 2,038 424 2,462 3,891 51 94 51 94 94 1-6 6-Hall/Stairs 59 496 0 496 559 7 23 7 23 23 1-4 7-Master Bedroom 243 3260 669 3,929 3,954 52 150 , 52 150 150 2-5 8-WIC 86 731 74 805 1,991 26 34 26 34 34 1-4 9-Master Bath 110 927 97 1,024 2,780 37 43 37 43 43 1-4 10-Great Room 390 2,280 88 2,368 5,876 77 105 77 105 105 1-6 11-Dining 143 2,145 161 2,306 6,026 79 99 79 99 99 1--6 12-Kitchen 225 1294 89 1,383 3,536 47 60 47 60 60 1 13-Mud Room 103 894 94 988 2,668 35 41 35 41 41 1-4 14-Pantry 43 453 0 453 402 5 21 5 21 21 1-4 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\103 Burnt Hills Dr.rh9 Friday, October 06, 2017, 9:00 AM .khvac-!residential&Light Commercial HVAC Loads - Elite Software Development,Inc. Appolo Heating Inc. 1 103 Burnt Hills Dr j Schenectady, NY 12306 _ _ Page 5 Duct Size Preview j Room orMinimum � Maximum Roughs Desigri SP; Duce Ducts Source Htg Clg Act. Duct Duct Name I Velocity Velocity Factor L/10d Loss Velocity Length Flow Flow,. Flow Size I _ _. - System 1 Supply Runouts Zone 1 1-Basement Built-in 450 750 0.01 0.1 476.5 204 130 130 2-5 2-Foyer Built-In 450 750 0.01 0.1 552.3 33 48 48 1-4 3-Home Office Built-In 450 750 0.01 0.1 527.4 39 72 72 1-5 4-Bath 1 Built-In 450 750 0.01 0.1 497.3 27 43 43 1-4 5-Bedroom2 Built-In 450 750 0.01 0.1 478.4 51 94 94 1-6 6-Hall/Stairs Built-in 450 750 0.01 0,1 261.7 7 23 23 1-4 7-Master Bedroom Built-In 450 750 0.01 0.1 550.9 52 150 150 2-5 8-WIC Built-In 450 750 0.01 0.1 386.1 26 34 34 1-4 9-Master Bath Built-In 450 750 0.01 0.1 489.3 37 43 43 1-� I 10-Great Room Built-In 450 750 0.01 0.1 535.1 77 105. 105 1-6 11-Dining Built-In 450 750 0.01 0.1 503.3 79 99 99 1--6 12-Kitchen Built-In 450 750 0.01 0.1 683.1 47 60 60 1-A i 13-Mud Room Built-In 450 750 0.01 0.1 472.3 35 41 41 1- 14-Pantry Built-In 450 750 0.01 0.1 239.3 5 21 21 1--4 Other Ducts in System 1 I I Supply Main Trunk Built-In 650 900 0.003 0.1 824.9 720 962'; 962 12x14 Summary System 1 Heating Flow: 720 j Cooling Flow: _ 962 I i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\103 Burnt Hills Dr.rh9 Friday, October 06, 2017, 9:00 AM I� r R vah c--Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 103 Burnt Hills Dr Schenectady,NY 12306 Page 9 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 216.2 4,622 0 3,118 3,118 Front Door: Door-Front Door 21 246 0 82 82 Pella Slider: Door-Pella Slider 40.2 1,304 0 435 435 Fire Rated: Door-Fire Rated 21 246 0 82 82 12E-Osm: Wall-Frame, R-19 insulation in 2 x 6 stud 1170 8,316 0 1,735 1,735 cavity, no board insulation, siding finish, metal studs 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1665.4 7,468 0 1,332 1,332 cavity, no board insulation, siding finish,wood studs 166-38: Roof/Ceiling-Under Attic with Insulation on Attic 1665.4 2,986 0 2,033 2,033 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal,Tar and Gravel or Membrane, R-38 insulation 166-50: Roof/Ceiling-Under Attic with Insulation on Attic 276.6 382 0 260 260 I Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation I 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1772.4 3,057 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide j 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1634.8 12,501 0 2,174 2,174 i on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 307.2 2,539 0 441 441 on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl Subtotals for structure: 43,667 0 11,692 11,692 People: 3 900 1,200 2,100 Equipment: 0 0 0 Lighting: 2000 6,820 6,820 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 147, Summer CFM: 79 11,009 1,583 1,026 2,609 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 148 148 Total Building Load Totals: 54,676 2,483 20,886 23,369 Check Figures i i Total Building Supply CFM: 962 CFM Per Square ft.: 0.259 Square ft. of Room Area: 3,714 Square ft. Per Ton: 1,907 Volume (ft'): 31,509 Building Loads Total Heating Required Including Ventilation Air: 54,676 Btuh 54.676 MBH Total Sensible Gain: 20,886 Btuh 89 % Total Latent Gain: 2,483 Btuh 11 % Total Cooling Required Including Ventilation Air 23,369 Btuh 1.95 Tons(Based On Sensible+Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\103 Burnt Hills Dr.rh9 Friday, October 06, 2017, 9:00 AM Pp 9 - --- . AC fj 103 Burnt Hills Dr + hvac-_Residential&Light Commercial HVAC Loads Elite Software Development,Inc. A olo Heating Inc.Inc. >.. Schenectady, NY 12306 Page 38 S)/St2177 I ROOI]"l Load SC//?1/77ay H 9 CI9 Min Run Run CI Min Act I -_g Room Area Sens Htg Duct Duct Sens Lat Clg Sys I No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM , ---Zone 1- - --- 1 Basement 1,772 15,483 204 2-5 477 2,820 591 130 130 2 Foyer 103 2,532 33 1-4 552 1,046 89 48 48 3 Home Office 161 2,959 39 1-5 527 1,561 55 72 72 4 Bath 1 95 2,019 27 1-4 497 942 52 43 43 5 Bedroom 2 182 3,891 51 1-6 478 2,038 424 94 94 6 Hall/Stairs 59 559 7 1-4 262 496 0 23 23 7 Master Bedroom 243 3,954 52 2-5 551 3,260 669 150 150 8 WIC 86 1,991 26 1-4 386 731 74 34 34 9 Master Bath 110 2,780 37 1-4 489 927 97 43 43 10 Great Room 390 5,876 77 1-6 535 2,280 88 105 105 11 Dining 143 6,026 79 1-6 503 21145 161 99 99 i 12 Kitchen 225 3,536 47 1-4 683 1,294 89 60 60 1 13 Mud Room 103 2,668 35 1-4 472 894 94 41 41 l 14 Pantry 43 402 5 14 239 453 0 21 21 System 1 total 3,714 54,676 720 20,886 2,483 962 962 I System 1 Main Trunk Size: 12x14 in. Velocity: 825 ft./min Loss per 100 ft.: 0.108 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.95 89%/ 11% 20.886 2,483 23,369 Actual: 2.33 75%/25% 21,000 7,000 28,000 �uipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B* 13ACXN030-230-** Indoor Model: C35-30B*+TDR Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 28,000 Btuh Sensible Capacity: n/a 21,000 Btuh Latent Capacity: n/a 7,000 Btuh AHRI Reference No.: n/a 8736592 i i i i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\103 Burnt Hills Dr.rh9 Friday, October 06, 2017, 9:00 AM ptOZ `i,tienuep :pas! EOOZ `Ot I!adV.*pi 0�-7 `juewdolanaC, } opeW uois!n!pgns peso ino :aou9jeje l de, o Wp o w � 00 LLZ - -- D oon o 00 c O m r °`cam rEE / M (=: O O m X CO rn Z \ zoCO z 1 C1 l0 Sajov C-I Cc- t£ 107 �d'b ✓ 00 �Z£g9 N � fYr 308.12-1-31 RC-000639-2017 s / Michaels Group Homes LLC ' -+- / 103 Burnt Hills Drive, Lot 31 v / SFD w/FP 171 // � / 5 s.f., Garage 515 s.f. o J Map Reference: Map Of A Proposed Subdivision Made For Laric Development, LLC Dated.April 10, 2003 LOT 33 Last Revised:January 4, 2014 By: Van Dusen & Steves Filed: March 3, 2014, Plat C-349 LOT 34 LOT 32 I I s I SR�a� o ,y o 2s s °,., G F p {� N 00 68 e 325• LOT 31 54895. 1 Sq. Feet \ 1.3 Acres < AB50RPTION TRENGHE5 - �' '1484 3 • 50' EA. o (Pe / 09 ti O- o .11 ke/ r'01 01 \ \ 9/ . 0 0 Zy D15TRIBUTION BOX v s \ 5EPTIGGTANK LOT 29 i FEB 2 3 20 \ JUN OF QC1 Y \ LOT 30 iMLINII Y DEVELOPMENT LEGEND: = 5TREET SIGN \ =" �H = HYDRANT = WATER VALVE 1 2T12 i SEPTIC SYSTEM — AS BUILT BY NACE ENGINEERING Datei February /, 2018 Map of a Survey made for _ D u V P BEARING A L ALTERATION OR VEYOR TOA SURVEY Scale 1r-40' MAP TION OF A LICENSED UWD SURVEYORS SEAL IS A & NEW YORK S sTE DN AT sue aHstoN z OF THE Harry T r o e 1 s t r a NEW YORK STATE EDUCATION LAW. P ONLY COPIES FROM THE ORICMIAL�THIS SURVEY S- 1 yyy S t e v V s MARKED L LH E ORIGINAL D'THE LANDLI SURVEYORS 1 SHALL�CONSIDERED TO�VALID TRUE COPIES.- And — 1 'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE DOSTING CODE OF PRACTICE FOR LMD Land S u r v e ors LAND SURVEYORS.SAID CERTIFICATIONS SMALL RUIN ADOPTED V 6Y THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL ON THE PERSON FOR n WAVY.G PREPARED.AND Irene M. Billow Tr o e l s tr a 'r 1 OF 1 aR las eEFiNF To THE TITLE couPANY,GOVERNMENTAL 169 Haviland Road Queensbury, New York 12804 TO THE OF� Imo,,HEREON.A'� 1 2122118 SEPTIC AS BUILT MIGHAELS (518) 792-8474 New York Lic. No. 50135 Town of Queensbury, Warren County, New York NO. DATE DESCRIPTION DWG. NO. 99241-Lot 31