Loading...
RC-000688-2017 ma— _0" TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000688-2017 Tax Map No: 301.9-1-17.12 Permission is hereby granted to: Foothills Builders For property located at: 655 WEST MOUNTAIN RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvne of Construction Owner Name: Foothills Builders Single Family-New S150,000.00 Owner Address: 9 Mountainside DR Total Value S 150,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Foothills Builders 9 Mountainside DR Queensbury,NY 12804 Plans&Specifications Single-Family Dwelling w/gas FP 1,422 s.f. 2-car garage 528 s.f. $1,263.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,November 9,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expi ation date.) Dated at the Town of ueensb fhuot 9,2017 SIGNED BY: ��! r the Town of Queensbury. Director of Building&Code Enforcement PFINCIPAL ST UCTURE APPLICATION Office Use Only Date: ! � Permit No. RC 649-4-0 17 Tax Map ID 361, — — 17. /L Permit Fee o1o Zone Historic? _Yes Y No Rec Fee i Site Plan# Subdivision Name N/ A Lot# /JI A Subdivision# Project Location fo,Sf wt�3 mot4NTF�/,,, TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Foothills Builders Address 9 Mountainside Drive,Queensbury,NY 12804 r , Phone/Email (518) 796-3520/(518) 791-1933 /FoothillsBuildersNY@gmail.coru Applicant Foothills Builders i Q 1 20 1 Address 9 Mountainside Drive,Queensbury,NY 12804 TOWN OF QUEEN 3BURY Phone/Email (518) 796-3520/(518) 791-1933 /FoothillsBuildersNY@gmail.com COW UNITY PMEI Contractor Foothills Builders Address 9 Mountainside Drive, Queensbury,NY 12804 Phone/Email (518) 796-3520/(518) 791-1933/FoothillsBuildersNY@gmail.com Contact Person for Building& Codes Compliance: -�yd€ t_E Phone 1-10, 33 TYPE OF CONSTRUCTION ✓Check all that apply New Addition Alteration 1"floor sf 2nd floor sf Total sf Height Single Family ' f 2 z ry z->, 2 2 Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage b (1'( 2,)3, 4+) Z Z 2 0 Other Town of Queensbury Building&Codes Principal Structure Application revised January 2016 a If commercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Gas Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances& Chimneys '�s , G-q S Are there structures not shown on plot plan? h,d Are there easements on the property? V v Site Information: a. Dimensions or acreage of lot j, o q c S b. Is this a corner lot? Yes _ D_No c. Will the grade be changed as a result of construction esDom_No d. Public water or Private well(circle one) P Private e. Sewer or Private Septic System(circle one) Sewer QLJLvate Value of all work to be performed(labor or materials) $ S , o oy DECLARATION: 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement I description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: J o S (�P A LF k L4 DATE: 111, 11 SIGNATURE: cvx DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only DATE: I� / 17 L , < p ID b' TAx MAP ID: 301. 9 — l - I • ! 2- ZONE: 71 ZONE: NOV 01 2011ee TOWN OF QUEENSBURY (518) 796-3520/ OWNER Foothills Builders IL (518) 791-1933 ADDRESS 9 Mountainside Drive,Queensbury,NY 12804 FoothillsBuildersNY@gmail.com INSTALLER/ PHONE/E-MAIL Foothills Builders BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: LEU (-I PHONE/E-MAIL (518) 796-3520/(518) 791-1933 BUILDING ADDRESS 6_�S CJ 6-S T t"6 u N7 A 1 FoothillsBuildersNY@gmail.com ROOM OF INSTALL: G'RI�R T keC -Y\ PLANNED INSTALL DATE: 12- FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: ROUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: FIREPLACE,MASONRY MANUFACTURER'S INSTALLATION MANUAL FURNACE(GARAGE ONLY MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: ; Model#: Listed by: Number: CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE ✓ STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: ; Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINTNAME: -16 Ir Le-LI L DATE: SIGNATURE: A DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: [ 1 ( l Tax Map ID TAx MAP ID: L Permit No. ZONE: Permit Fee YYl � (518)796-3650/ APPLICANT Foothills Builders PHONE/E-MAIL 1 (518)791-1933 ADDRESS 9 Mountainside Drive Queensbury,NY 12804 FoothillsBuildersNY@gmail.com INSTALLER/ PHONE/E-MAIL Same as above BUILDER Foothills Builders OWNER Foothills Builders ADDRESS 9 Mountainside Drive Queensbury,NY 12804 CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: Joe Leuci PHONE/E-MAIL (518)796/3520/ (518)791-1933 / FoothillsBuildersNY@gmail.com RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older ' Garbage grinder installed Yes '�No 1981-1991 Spa or Hot Tub installed Yes K No 1992-Present .3 336 PARCEL INFORMATION Topography �_Flat rolling Steep slope %Slope Soil Nature x_Sand Loam Clay Other Groundwater At what depth: N A Bedrock/Impervious material At what depth: N A Domestic Water Supply _X_Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: Ci ' per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size t0 o c gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with#2 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: —_ ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks, Nates; 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: s t P rl EtL DATE: SIGNATURE: - DATE: —1 Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: 1 I /I //-) Applicant Name: Foothills Builders Telephone No.: (S 18)7 1 1 - I g 3 3 Address to be Inspected (v S-3 wCS 1 M o`^W i A 1 N f�D Return Address: 9 Mountainside Drive Queensbury,NY 12804 Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness,Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 NORTH EAST BUILDING PERFORMANCE ADVISORS ........................................................................................................................................... Serving the Capital District, Saratoga and Adirondack Regions January 29, 2018 7 Rocky Ridge, Warrensburg, NY 12885 Foothill Builders LLC 9 Mountainside Drive Building Permit #: Queensbury, NY 12804 RC-000688-2017 RE: Blower Door Test for NYS Building Code, Town of Queensbury Mr. Joseph Leuci: After inspection of the New 1 Story Home at 655 West Mountain Rd., Queensbury, New York and completion of a Blower Door Test consistent with the practice of depressurization to 50 Pascal in a winter condition with the exterior windows and doors shut and the interior doors to all the rooms open, my observations are as follows: ❖ This home tested passed the current New York State Building Code for Air Changes per Hour @ 50 Pascal of less than or equal to 3 ACH/50 (for Homes permitted after November Ist, 2016). The tested number is 2.24 ACH/50 Pascal. ❖ The total volume of conditioned space at 655 West Mountain Rd. is 25657.6 cubic feet taking into consideration all conditioned space in the home. The cubic feet per minute @ 50 Pascal was 956 CFM/50. The height correction factor for New York State is 19 for a one story building, as such the tested home @ 655 West Mountain Rd. has the natural rate of air exchange of 0.12 air changes per hour/natural or 5 0.3 2 cfin natural infiltration credit based on the blower door test. ❖ In the latest (2013)version of ASHRAE 62.2,high-performance homes need to be ventilated at 7.5 cfin per person plus 3 cfin per 100 square feet. That means for 4 people it would need 1422 sq ft/100 times 3 cfin= 42.66 cfin+ 30 cfin or 72.66 cfin. It would also be advantageous to use the bathroom and kitchen fans to help control humidity and improve indoor air quality. ❖ My credentials are as follows: ➢ BPI Certified Building Analyst ➢ BPI Certified Envelope Specialist ➢ BPI Certified Heating Professional ➢ HERS Rater ❖ If you have any questions regarding my findings please feel free to contact me. Sincerely, Jack raw view 1.888.472.2774 7 Rocky Ridge Road 4A Vatrano Drive Warrensburg, NY 12885 Albany, NY 12205 Phone (518)623.7016 Phone (518)350.2941 Fax (518)623.7015 Fax (518)694.0102 Manual S Compliance RepoZ L� �F'a� 2617 ndr°e louse ___Ft�t7THILL BUILDERS OV 0 7 659 WEST MNT RD, QUEENSBURY,NY 12804 110 Project For: JOE, FOOTHILL BUILDERS 659 WEST MN T RD, QUEENSBURY, NY 12804 Coolinu Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 21896 Btuh Entering coil DB: 75.9°F Outdoor design WB: 71.0°F Latent gain: 7323 Btuh Entering coil WB: 63.4°F Indoor design DB: 75.0°F Total gain: 29220 Btuh Indoor RH: 50% Estimated airflow: 973 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: YCJF30S4lSl+ASL*3018A33E+T*(8,L)V*Al2+D+V Actual airflow: 973 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 93702 Btuh Entering coil DB: 65.1°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TG9S120D16MP11 Actual airflow: 2135 cfm Output capacity: 116000 Btuh 124% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. I— wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 2017-Nov-06 16:07:17Page 1 �C�. ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=M.18 House Front faces: N R idential Plans Examiner Review Form for ®e • (Loads, • • Ducts) , 'lis Mar 09 OU15ENSBURY NY Header Information Contractor: FOOTHILL BUILDERS REQUIRED ATTACHMENTS ATTACHED Manual J 1 Form(and supporting worksheets): Yes ❑ No Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes F-I No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#: 1294 Manual D Friction Rate Worksheet: Yes ❑ No M Duct distribution sketch: Yes ❑ No FJ Home address(Street or Lot#,Block,Subdivision): 659 WEST MNT RD, Entire House Design Conditions Building Construction Information `Minter Design Conditions Building Outdoor temperature: -4 OF Orientation: House Front faces North Indoor temperature: 68 of North,East,west,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 93702 Btuh Number of bedrooms: 0 Conditioned floor area: 4746 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 OF Indoor temperature: 75 OF windows Roos Grains difference: 28 gr/Ib 50% RH Eave overhang depth: 0 ft Sensible heatain: ' 9 24329 Btuh Internal shade: none Eave Latent heat gain: Bfinds,drapee,etc. 9 8137 Btuh Depth Wtn9mv Total heat gain: 32466 Btuh Number of skylights: 0 H-VAC EQUIPMENT • 41 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace E%ipment type: SplitAC Heating cfm: 2135 umace,Heatpump,Boller,etc. it onditioner,Heat pump,etc. Cooling cfm: 973 Model: York Model: York Static pressure: 0 in H2O TG9S120D16MP11 YCJF30S41 S1 Fan's rated external Static pressure for design airflow Heating output capacity: 116P00 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design oudoorconditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh ° DUCT DISTRIBUTION SYSSTEM OEM-N ORC M101 Design airflow: 2135 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: o in/100ft Branch duct: Sheet metal Friction Rate=ASP+(TEI-x 100) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved •_ - *Home qualifies for MJ1AE Form based on Abridged Edition Checklist FF wrightsaft* Right-Suite®Universal 2017 17.0.16 RSU25116 P'rpieet Summary Job: i294fate: Novi�e�v 66,2017 Entire House 13 Y: FOOTHILL BUILDERS Plan: i294 659 WEST MNT RD, QUEENSBURY NY 12804 Information For: JOE, FOOTHILL BUILDERS 659 WEST MNT RD, QUEENSBURY, NY 12804 Notes: Desic in Information Weather: Glens Falls AP, NY, US Winter design Conditions Summer Design Conditions Outside db -4 OF Outside db 85 OF Inside db 68 OF Inside db 75 QF Design TD 72 OF Design TD 10 `F Daily range M Reative humidity 50 % Moisture difference 28 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 83150 Btuh Structure 20016 Btuh Ducts 10552 Btuh Ducts 1881 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 93702 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 In'f'iltration Equipment sensible load 19707 Stuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 0 Structure 3830 Btuh Ducts 3493 Btuh Central vent (0 cfm) 0 Btuh Pleating Cooling (none) Area(ftZ 4746 4746 Equipment latent load 7323 Btuh Volume (ft') 42714 42714 Air changes/hour 0.56 0.29 Equipment total load 27030 Btuh Equiv.AVF (cfm) 399 206 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade AIRSTAR, TFC, MERIDIAN Model TG9S120D16MP11 Cond YCJF30S41S1 AHRI ref 2008577 Coil ASL*3018A33E+T*(8,L)V*Al2+D+V A H R I ref 4436959 Efficiency 95.5AFUE Efficiency 12.5 EER, 15 SEER Heating input 120000 Btuh Sensible cooling 20440 Btuh Heating output 116000 Btuh Latent cooling 8760 Btuh Low output baseboard 700 Btuh/ft Total cooling 0.044 cfm/Btuh Total low baseboard 134 ft Actual air flow 0 in H2O High output baseboard Air flow factor 0.75 Total high baseboard Static pressure Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Nov-06 16:07:17 wriightSOft' Right-Suitee Universal 2017 17.0.16 RSU25116 Page 1 ACCP ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N AED Assessment Join: i294 Dais: NOV 06,2017 Entire Nouse ay: FOOTHILL BUILDERS reran: 1294 659 WEST MNT RD, QUEENSBURY,NY 12804 Pro-jinformation For: JOE, FOOTHILL BUILDERS 659 WEST MNT RD, QUEENSBURY, NY 12804 Design r . r Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 68 75 Elevation: 335 ft Design TD (°F) 72 10 Latitude: 43oN Relative humidity (%) 50 50 Outdoor: Heating Coaling Moisture difference(gr/Ib) 48.0 27.6 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 20 ( M ) Wet bulb (°F) - 71 Wind speed (mph) 15.0 7.5 Test forAdequate Exposure Diversity Hourly Glazing Load 7,000-- 6,000-- 5,000 ,0006,0005,000 m 4,000-- 0 01 C N 0 3,000-- 2,000-- 1,000-- 0 ,0002,0001,0000 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day /Houry /Avemge /AED Gnat Maximum hourly glazing load exceeds average by 36.8%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 324 Btuh (PFG - 1.3*AFG) 2017-Nov-06 16:07:17 wrightsoft® Right-Suitee Universal 2017 17.0.16 RSU25116 Page 1 .00. ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N Right-J- 8 Worksheat job: ;2�4 E&ire House Date: MOV 06, 50il 5y: FOOTHILL BUILDERS 659 WEST MNT RD, QUEENSBURY, NY 12804 1 Room name Entire House Room2 2 Exposed wall 548.0 ft 200.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1988.0 ft 5 Room area 4746.0 ft2 1988.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft') or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 1485 1383 9061 2077 495 495 3243 743 1 D-c2ov 0.570 n 41.04 16.36 60 0 2462 982 0 0 0 0 D 11D0 0.390 n 28.08 8.38 42 42 1179 352 0 0 0 0 W 12C-Osw 0.091 e 6.55 1.50 981 981 6428 1473 405 405 2654 608 11 W 12C-0sw 0.091 s 6.55 1.50 1485 1398 9160 2099 495 495 3243 743 1 D-c2ov 0.570 s 41.04 30.57 45 0 1847 1376 0 0 0 0 D 11D0 0.390 s 28.08 8.38 42 42 1179 352 0 0 0 0 W 12C-Osw 0.091 w 6.55 1.50 981 951 6231 1428 405 385 2523 578 IL—G 1D-c2ov 0.570 w 41.04 58.17 30 0 1231 1745 20 0 821 1163 C 16B-30ad 0.032 - 2.30 1.44 3334 3334 7682 4801 576 576 1327 829 F 19A-19bscp 0.049 2.76 0.38 1988 1988 5496 763 1988 1988 5496 763 6 c)AED excursion 324 298 Envelope loss/gain 51957 17772 19307 5727 12 a) Infiltration 31194 2244 11385 819 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 83150 20016 30691 6546 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 83150 20016 30691 6546 15 Duct loads 13% 9% 10552 1881 13% 9% 3895 615 Total room load 93702 21896 34586 7161 LowlHigh Baseboard/Cool Air 187 134 973 69 49 318 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -t"+ wrights4o t 2017-Nov-0616:07:17 r Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 �` ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N R,ig 1t-J@ Worksheet jai : i294 Efitire House pare: Nov 06, 20i FOOTHILL BUILDERS pran: 1294 659 WEST MNT RD, QUEENSBURY, NY 12804 1 Room name Roomy Roomy 2 Exposed wall 174.0 ft 17.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 1412.0 ft 5.0 x 12.0 ft 5 Room area 1412.0 ft2 60.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 495 495 3243 743 45 45 295 68 1 D-c2ov 0.570 n 41.04 16.36 0 0 0 0 0 0 0 0 D 11D0 0.390 n 28.08 8.38 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 e 6.55 1.50 288 288 1887 432 0 0 0 0 11 W 12C-Osw 0.091 s 6.55 1.50 495 495 3243 743 0 0 0 0 1 D-c2ov 0.570 s 41.04 30.57 0 0 0 0 0 0 0 0 D 11 DO 0.390 s 28.08 8.38 0 0 0 0 0 0 0 0 IW 12C-Osw 0.091 w 6.55 1.50 288 288 1887 432 108 98 642 147 L_G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 10 0 410 582 C 16B-30ad 0.032 2.30 1.44 1412 1412 3253 2033 60 60 138 86 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion -258 259 Envelope loss/gain 13514 4126 1486 1142 12 a) Infiltration 9905 712 968 70 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1 23418 48391 2453 1212 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23418 4839 2453 1212 15 Duct loads 13% 9% 2972 455 13% 9'/01 311 114 Total room load 26390 5293 2765 1326 LowlHigh Baseboard/Cool Air 53 38 235 1 6 4 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI®gFlt ®F 2017-Nov-06 16: e 2 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N R6C1ht-J)Worksheet jab: i294 Edure House Osie: Nov 06, MY By: I✓61t'TRILL BUILDERS Plait: i254 659 WEST MNT RD, QUEENSBURY,NY 12804 1 Room name Room8 Room9 2 Exposed wall 15.0 ft 14.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 74.0 ft 14.0 x 12.0 ft 5 Room area 74.0 ft2 168.0 ft2 Ty Construction U-value Or HTM Area (fv) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Meat Cool 6W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 126 96 629 144 1D-c2ov 0.570 n 41.04 16.36 0 0 0 0 30 0 1231 491 D 11D0 0.390 n 28.08 8.38 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 a 6.55 1.50 0 0 0 0 0 0 0 0 11 IW 12C-Osw 0.091 s 6.55 1.50 45 45 295 68 0 0 0 0 1-c� 1 D-c2ov 0.570 s 41.04 30.57 0 0 0 0 0 0 0 0 D 11 DO 0.390 s 28.08 8.38 0 0 0 0 0 0 0 0 Wj 12C-Osw 0.091 w 6.55 1.50 90 90 590 135 0 0 0 0 W G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 2.30 1.44 74 74 170 107 168 168 387 242 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion -19 -47 Envelope loss/gain 1055 290 2247 829 12 a) Infiltration 854 61 797 57 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1909 352 3044 887 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1909 352 3044 887 15 Duct loads 13% 9% 242 33 13% 9% 386 83 Total room load 2151 385 3430 970 1 11LowlHigh Baseboard/Cool Air 4 3 17 7 5 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrights®fft" 2017-Nov-06 16:07:17 ACCP. Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3 ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N Right-M Worksheet Job: 1294 Entire House Gate: Nov 06, 2677 FOOTHILL BUILDERS filar: 1294 659 WEST MNT RD, QUEENSBURY, NY 12804 1 Room name Room10 Room1l 2 Exposed wall 10.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 10.0 x 4.0 ft 7.0 x &0 ft 5 Room area 40.0 ft2 42.0 ft2 Ty Construction LI-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S peat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 n 41.04 16.36 0 0 0 0 0 0 0 0 D 11D0 0.390 n 28.08 8.38 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 e 6.55 1.50 0 0 0 0 0 0 0 0 11 W12C-Osw 0.091 s 6.55 1.50 90 90 590 135 0 0 0 0 1 D-c2ov 0.570 s 41.04 30.57 0 0 0 O 0 0 0 0 D 11D0 0.390 s 28.08 8.38 0 0 0 0 0 0 0 0 IW 12C-Osw 0.091 w 6.55 1.50 0 0 0 0 0 0 0 0 �—G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 2.30 1.44 40 40 92 58 42 42 97 60 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion -12 -3 Envelope loss/gain 682 181 97 57 12 a) Infiltration 569 41 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1251 222 97 57 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1251 222 97 57 15 Duct loads 13% 9% 159 21 13% 9% 12 5 Total room load 1410 243 109 63 LowjHigh Baseboard/Cool Air 3 2 11 01 0 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft. 2017-Nov-06 16:07:17 Right-Suite@ Universal 2017 17.0.16 RSU25116 Page 4 ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N Right-J)Worksheet job: 1294 Efitire House Dara: Nov 06, 201'! FOOTHILL BUILDERS i��ats: i294 659 WEST MNT RD, QUEENSBURY, NY 12804 1 Room name Room12 Room13 2 Exposed wall 5.0 ft 45.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 5.0 X 4.0 ft 1.0 x 540.0 ft 5 Room area 20.0 ft2 540.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Meat Cool 6 W 12C-Osw 0.091 n 6.55 1.50 0 0 0 0 189 132 865 198 1D-c2ov 0.570 n 41.04 16.36 0 0 0 0 15 0 616 245 D 11D0 0.390 n 28.08 8.38 0 0 0 0 42 42 1179 352 W 12C-Osw 0.091 e 6.55 1.50 0 0 0 0 0 0 0 0 11 W12C-Osw 0.091 s 6.55 1.50 45 24 157 36 180 129 845 194 1D-c2ov 0.570 s 41.04 30.57 0 0 0 0 30 0 1231 917 D 11 DO 0.390 s 28.08 8.38 21 21 590 176 21 21 590 176 W12C-Osw 0.091 w 6.55 1.50 0 0 0 0 36 36 236 54 G I D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 2.30 1.44 20 20 46 29 540 540 1244 778 F 19A-19bscp 0.049 - 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion -13 104 Envelope loss/gain 793 228 6806 3018 12 a) Infiltration 285 20 2562 184 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1078 248 9367 3202 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1078 248 9367 3202 15 Duct loads 13% 9% 137 23 13% 9% 1189 301 Total room load 1214 271 10556 3503 LowlHigh Baseboard/Cool Air 2 2 12 21 15 156 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AwrightSOft" 2017-Nov-0616:07:17 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 5 angewo thy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N Fight-J)Worksheet job: 1254 Fluff a House Dai:a: Nov 069 2011 FOOTHILL BUILDERS r: 659 WEST MNT RD, QUEENSBURY, NY 12804 1 Room name Room14 Room15 2 Exposed wall 27.0 ft 5.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 168.0 ft 9.0 x 5.0 ft 5 Room area 168.0 ft2 45.0 ft2 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft?°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6W 12C-Osw 0.091 n 6.55 1.50 135 120 786 180 0 0 0 0 1D-c2ov 0.570 n 41.04 16.36 15 0 616 245 0 0 0 0 D 11D0 0.390 n 28.08 8.38 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 e 6.55 1.50 108 108 708 162 45 45 295 68 11 W 12C-Osw 0.091 s 6.55 1.50 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 s 41.04 30.57 0 0 0 0 0 0 0 0 D 11 DO 0.390 s 28.08 8.38 0 0 0 0 0 0 0 0 WI 12C-Osw 0.091 w 6.55 1.50 0 0 0 0 0 0 0 0 G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 2.30 1.44 168 168 387 242 45 45 104 65 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 0 0 0 0 6 c)AED excursion -48 -8 Envelope loss/gain 2497 782 399 125 12 a) Infiltration 1537 111 285 20 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4033 893 683 145 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4033 893 683 145 15 Duct loads 13% 9% 512 84 13% 9% 87 14 Total room load 4545 976 770 159 LowlHigh Baseboard/Cool Air 9 6 43i 2 1 7 Calculations approved by RCCA to meet all requirements of Manual J 8th Ed `++- Wrightsaft Right-Suite®Universal 2017 17.0.16 RSU25116 2017-Nov-06 16:07:17 SCG langeworthy\Documents\York1659 WEST MNT RD.rup Calc=MJ8 House Front faces: N Page 6 .Right-J@ Worksheat job: 1294 Entire House baia: Nov 06, 20i"* FOOTHILL BUIL09RS Fran: i294 659 WEST MNT RD, QUEENSBURY,NY 12804 1 Room name Room16 2 Exposed wall 36.0 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 189.0 ft 5 Room area 189.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S 1-peat Cool 6 W 12C-0sw 0.091 n 6.55 1.50 0 0 0 0 1 D-c2ov 0.570 n 41.04 16.36 0 0 0 0 D 11D0 0.390 n 28.08 8.38 0 0 0 0 W 12C-Osw 0.091 e 6.55 1.50 135 135 885 203 11 W 12C-Osw 0.091 s 6.55 1.50 135 120 786 180 1 D-c2ov 0.570 s 41.04 30.57 15 0 616 459 D 11 DO 0.390 s 28.08 8.38 0 0 0 0 W12C-Osw 0.091 w 6.55 1.50 54 54 354 81 —G 1 D-c2ov 0.570 w 41.04 58.17 0 0 0 0 C 16B-30ad 0.032 - 2.30 1.44 189 189 435 272 F 19A-19bscp 0.049 2.76 0.38 0 0 0 0 6 c)AED excursion 71 Envelope loss/gain 3076 1266 12 a) Infiltration 2049 147 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 5125 1413 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 5125 1413 15 Duct loads 13% 9% 650 133 Total room load 5775 1546 LowlHigh Baseboard/Cool Air 1 1121 8 69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A wrightsOft 2017-Nov-06 16: ge 7 Right-SuiteO Universal 2017 17.0.16 RSU25116 Page 7 ....langeworthy\Documents\York\659 WEST MNT RD.rup Calc=MJ8 House Front faces: N REScheck Software Version 4.6.4 Compliance Certificate CE0VE , Project Foothills Builders Energy Code: 2015 IECC J NOV 0 1 2017 Location: Glens Falls, New York Construction Type: Single-family TOWN OF QUEENSBURY Project Type: New Construction COMMUNITY DEVELOPMENT Conditioned Floor Area: 1,422 ft2 Glazing Area 11% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: ` 69-4'West Mtn Road VISION Engineering, LLC if Queensbury, NY 12804 206 Glens Street Suite 56 Glens Falls, NY 12801 ses using UA tMde-off Compliance: 0.0%Better Than Code Maximum UA: 232 Your UA: 232 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cant. Assembly or U-Factor UA Perimeter Ceiling 1: Flat Ceiling or Scissor Truss 1,422 38.0 0.0 0.030 43 Wall 1: Wood Frame, 16" D.C. 1,566 21.0 0.0 0.057 79 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 102 0.290 30 Door 1: Solid 18 0.140 3 Door 2: Glass 40 0.290 12 Door 3: Solid 20 0.200 4 Basement Wall 1: Solid Concrete or Masonry 1,357 0.0 19.0 0.039 52 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Window 2: Vinyl/Fiberglass Frame:Double Pane 9 0.400 4 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 301.9-1-17.12 RC-000688-2017 Foothills Builders 655 W. Mountain Road SFD w/FP 1422 s.f., Garage 528 s.f. Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294 - DES - Page 1 of 10 FHB Eft West Mtn Rd\1294 Rescheck.rck �S � } Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calcula 'ons submitted with t e permit application.The proposed building has been designed to meet the 2015 IECC requirements in RESch ck V rsion 4.6.4 a to comply with the mandatory requirements li 1 the REScheck Inspection Checklist. Na Title Signa re Dat C L!1 i I LI �0 0790 \o, IO fA Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294 - DES - Page 2 of 10 FHB 659 West Mtn Rd\1294 Rescheck.rck r CREScheck Software Version 4.6.4 �(J Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # i Pre-inspection/Plan Review Complies? Comments/Assumptions 6i Re iD__ value I Value 103.1, :Construction drawings ands❑Complies 103.2 `documentation demonstrate ❑Does Not [PR1)1 energy code compliance for the 4 building envelope.Thermal ❑Not Observable .envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3)1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. jHeating and cooling equipment is Heating: Heating: ❑Complies sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not on loads calculated per ACCA Cooling Coolin g ❑Not Observable N Manual J or other methods Btu/hrBtu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) '' Medium Impact(Tier 2) [,*--,,-,]Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294- DES - Page 3 of 10 FHB 01!9 West Mtn Rd\1294 Rescheck.rck ~ ~ Section Plans Verified Field Verified # Foundation Inspection Value Value lies? Comments/Assumptions lReq.10 —Comp 402.1.1 Conditioned basement wall R- R- ElComplies See the Envelope Assemblies (F0411 insulation R-value. Where interior R_ R- E]Does Not table For values. insulation is used, verification E]Not Observable .may need to occur during Insulation Inspection. Not []Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall 'ElComplies (F0511 insulation installed per ElDoes Not manufacturer's instructions. ��,�E]Not Observable "EINot Applicable 402.2.9 Conditioned basement wall ft ft ElComplies See the Envelope Assemblies [F0611 insulation depth of burial or E]Does Not table for values. distance from top of wall. 14. - []Not Observable E]Not Applicable 3031.1 A protective covering is installed L.A 'to protect exposed exterior E]Does Not insulation and extends a E]Not Observable ;minimum of 6 in. below grade. E]Not Applicable 403.9 Snow-and ice-melting system '�,IME]Com plies [FO1212 controls installed. E]Does Not -'�,'E]Not Observable pnp,U]Not Applicable AdditiomaUCommmmamts/Asswmmptioms: [1 H�ig h I m p�act(Ti e�rl) �2M�ecfium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Foothills Builders Report date: I0/26/17 Data filename: C:\Users\DVVR Desktop\Dnopbox\V|S|ON Engineering' LL[\Active Projects VE\lZ94 ' DES ' Page 4of10 FHB §59West Mtn Rd\lZ94Rescheck.rrk ., Section Plans Verified Field Verified ° # Framing/Rough In InsPecYion Value Value Complies? Comments/Assumptions = & Re IG 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 ;[]Not Observable ; ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies ;See the Envelope Assemblies 402.3.1, average). ❑Does Not ,table for values. , 402.3.3, 402.3.6, []Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 :are determined in accordance _ ❑Does Not = -with the NFRC test procedure or []Not Observable , taken from the default table. i"WiA&E]Not Applicable ; 402.4.1.1 :Air barrier and thermal barrier r ❑Complies ; [FR23]1 !installed per manufacturer's e ❑Does Not instructions. ❑ : � Not Observable „g v ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies ; [FR2011 Is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ` or has infiltration rates per NFRC ❑Not Observable ; 400 that do not exceed code + ❑Not Applicable t limits. F, IC-rated recessed lighting fixtures N/ g❑Complies T sealed at housing/interior finish ❑Does Not and labeled to indicate 252.0 cfm ❑Not Observable f leakage at 75 Pa. ❑Not Applicable 403.2.1 :Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is �+ 3 ❑Does Not >= 3 inches in diameter and >_ r []Not Observable 11-6 where< 3 inches.Supply and return ducts in other portions of R❑Not Applicable the building insulated >= R-6 for 3 diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3��.'� Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable 3 ❑Not Applicable 403.E HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ;❑Does Not "below 55 4F are insulated to aR- �- [:]Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies JFR2411 piping. ❑Does Not r ❑Not Observable ; ❑Not Applicable 1403.5.3 Hot water pipes are insulated to R- R- i❑Complies [FR18]2 >_R-3. ]Does Not , ;❑Not Observable ; ❑Not Applicable X403.6 Automatic or gravity dampers are ❑Complies [FR1912 installed on all outdoor air `: ❑Does Not intakes and exhausts. ❑Not Observable 3 ❑Not Applicable + 1 IHigh Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294- DES- Page 5 of 10 FHB 859 West Mtn Rd\1294 Rescheck.rck 4S< r Additional Comments/Assumptions: 1 ;High h Impact(Tier 1) Z ' Medium Impact(Tier 2) 3'Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294- DES - Page 6 of 10 FHB 659 West Mtn Rd\1294 Rescheck.rck j Section 1 I Plans Verified d Held Verifie # Insulation Inspection I Value Value � Complies? Comments/Assumptions 303,1 '.AII installed insulation is labeled ❑Complies fIN13I2 orthe installed R-values ❑Does Not provided. „❑Not Observable fVVNE]Not Applicable 402.1.1, Wall insulation R-value. If this is a: R- R- ❑Complies !See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass []Not Observable [IN311 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per j 21J, ❑Complies [IN411 manufacturer's instructions. �y "'❑Does Not r Q -� ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2, Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294 - DES - Page 7 of 10 FHB 659 West Mtn Rd\1294 Rescheck.rck section' Plans Plans Verified � Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &&Re ,I 111 402.1.11 Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [F11)1 ❑Not Applicable 303.1.1.1, ,Ceiling insulation installed per , ❑Complies 303.2 manufacturer's instructions. r ❑Does Not [FI211 Blown insulation marked every -]Not ft2. ti' Not Observable ... ❑Not Applicable W .2.3 Vented attics with air permeable ❑Complies [%122]1 insulation include baffle adjacent f Y s'.-❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable i❑Not Applicable E 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation ?R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable _ ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 []Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 []Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. ®._...._..._......._........_.._.......___........._..._............_............._............_........ .._.......___..._......._._........_ 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air ; handler enclosure. 403.3.2.1 'Air handler leakage designated ❑Complies [F124]1 by manufacturer at <=2%of ❑Does Not design air flow. ❑Not Observable ; ❑Not Applicable 403' Programmable thermostats ❑Complies [Fl 9 installed for control of primary h ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403:1.2 Heat pump thermostat installed iplies [Fi10]2 on heat pumps. LJ Does Not ❑Not Observable 1, ❑Not Applicable 403,5.1 Circulating service hot water Y ❑Complies CF11112 systems have automatic ory: ❑Does Not accessible manual controls. ❑Not Observable ; ❑Not Applicable 11 High Impact(Tier 1) ",';Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294- DES - Page 8 of 10 FHB 659 West Mtn Rd\1294 Rescheck.rck S ctivrs Pians Verified 1 Field Verified Final Inspection ProvisionsPlans Value Compile!? Comments/Assumptions 403.6.1 All mechanical ventilation system ❑Complies [F125}2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126] 9 p P 9 h one-or two- heating i e through ❑Does Not �e} systems have outdoor setback ❑Not Observable control to lower boiler water t ,❑ temperature based on outdoor Not Applicable r TM temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ti s ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe. Gravity and thermos ❑Not Applicable syphon circulation systems are not present.Controls for xy m circulating hot water system Iz pumps start the pump with signal for hot water demand within the 21 w occupancy. Controls , automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. ., ,. 403.5.1.2 Electric heat trace systems ❑Complies [F12 9]2 comply with IEEE 515.1 or UL r' ❑Does Not 515. Controls automatically 3 , adjust the energy input to the �' `g [:]Not Observable heat tracing to maintain the []Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [FI30]z have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a 4 demand recirculation water aw system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. „-;- 403.5.4 Drain water heat recovery units 2`01 ❑Complies (F13 112 tested in accordance with CSA � z3z ❑Does Not B55.1. Potable water-side pressure loss of drain water heatY' R ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one ' or two showers. Potable water- f side pressure loss of drain water z ,k heat recovery units< 2 psi for individual units connected to a three or more showers. ' 404.1 75%of lamps in permanent 's a f ❑Complies t [FI6]1 fixtures or 75%of permanent —, '❑Does Not fixtures have high efficacy lamps. -]Not Observable Does not apply to low-voltage 6 lighting. ❑Not Applicable '404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ` ❑Does Not ❑Not Observable ❑Not Applicable 1 j High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294 - DES - Page 9 of 10 FHB 6M West Mtn Rd\1294 Rescheck.rck v Sec Ion Plans Verified field Verified # final Inspection Provisions Value Value Complies? Comments/Assumptions,' & Req.il.I 40 .3 Compliance certificate posted. ❑Complies [F1711 �� '❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F[18]3 mechanical and water heating []Does Not systems have been provided. �NU ❑Not Observable F ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 10/26/17 Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1294 - DES- Page 10 of 10 FHB 659 West Mtn Rd\1294 Rescheck.rck A 2015 IECC Energy Efficiency Certificate Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Window 0.29 Door 0.29 Heating System• Cooling System: Water Heater: Name• Date: Comments