Loading...
RC-000704-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000704-2017 Tax Map No: 308.19-1-14 Permission is hereby granted to: Honey-Do Man LLC For property located at: 3 MORNINGSIDE CIR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Cindy Blake Single Family-Addition $34,500.00 Owner Address: 3 MORNINGSIDE CIR Total Value $34,500.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Honey-Do Man LLC 442 CORINTH RD Queensbury,NY 12804 Plans&Specifications Residential Addition 380 s.f. $100.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,November 21,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensb efore the exw*ation date.) Dated at the Town o Queens )j;, W21,2017 Tue P, SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement office i;se ui,;Iy - ADDITION/ALTERATION pERIlfllT � APPLICATION Per.-nit Fee: $ 100 .00 742 Bay Road,Queensbury, NY 12804 ;ilvoice 4: P:18-761-8256 www.gueensburV.net Tax map 9® #o ? �.l� - . �t� - Subdivision N CONTACT INFORMATION' T�BLIILD N D&C�DtSRY Applicant / Name(s): KE-,j li..t /1 i.kC.Y_Q. Mailing Address, C/S/Z: 4yZ. 1" Cell Phone: ( 51& ) 21yo -LA10 Land Email: hone." - &*j�� t .1. Ca Primary Owner(s): Name(s): 'letAOkAilk 4w 1�1 -1 Mailing Address, C/S/Z: 3 ) S1de C%2.6(- Cell t t.Cell Phone: Land Line: ( SIPS ) 79Z-5/9G Email: ® Contractor(s): Business dame: Contact Name(s): J�F_v li v► <xucsk_ Mailing Address, C/S/Z: 144Z 0cqy4,, /\IyZ Cell Phone: ( 5(8 ) 2(,00 .y610 Land Line: � ) Email: horle�A- d6!4a^ 6.dlr^&%k.C6!A ® Architect(s)/Engineedsh Business Name: Contact Name(s): Mailing Address, C/S/Z: t ► p Q GIS 1`a11S WN 12,001 Cell Phone: Land Line: ( 51f Email: e_JQ6llbVnuCA.a.rr.C�A Contact Person for Building & Code Compliance: 4&J%" /lu�,KG2r Cell Phone: ( Sob ) 2uo • q&O Land Line: Email: h&AA.. Cko MOL A CO,,,•. Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 t PROJECT INFORMATION, TYPE: Commercial y Residential WORT( CLASS: Single-Family Two-Family _ Multi-Family (# of units ) Townhouse Business Office Retail Industrial/Warehouse _Garage (# of cars ) Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: !'�00 1st floor: 2nd floor: 2nd floor: 3rd floor: 3rd floor: 4th floor: 4th floor: Total square feet: 1560 Total square feet: ADDITIONAL PROJECT INFORMATION. 1. Estimated Cost of Construction: $ 2. If Commercial project, what is the proposed use: t4 IA 3. Source of Heat (circle one): Ga Oil Propane Solar Other Fireplaces need a separate Fuel Burning Appliances & Chimney Application 4. Are there any structures not shown on the plot plan? YES Explain: 5. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? �qs x Z1FJ b. Is this a corner lot? YE NO c. Will the grade be changed as a r construction? YES NO d. What is the water source? PUBLIC PRIVATE WELL e. Is the parcel on SEWER or a PRI DTIC system? sAiAlC, IF Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 r DECLAR FICO: 1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If thework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: rA 1�av� SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 REScheck Software Version 4.6.3 Compliance Certificate Project New Addition 308.19-1-14 RC-000704-2017 Blake, Cindy & Timothy Energy Code: 2015 IECC 3 Morningside Circle Location: Glens Falls, New York Construction Type: Single-family Residential Addition 380 s.f. Project Type: Addition Orientation: Unspecified Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Morningside Circle Kevin Tucker Ethan Peter Hall Queensbury, NY 12804 The Honey-Do Man Rucinski Hall Architecture Corinth Road 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com Compliance: Passes using UA trade-off Compliance: 2.5%Better Than Code Maximum UA: 79 Your UA: 77 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 380 49.0 0.0 0.020 8 Wall 1:Wood Frame, 16" D.C. 178 21.0 0.0 0.057 9 Orientation: Front Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.270 4 Orientation: Unspecified Wall 2:Wood Frame, 16"D.C. 169 21.0 0.0 0.057 8 Orientation: Right side Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 28 0.270 8 Orientation: Unspecified Wall 3: Wood Frame, 16" o.c. 178 21.0 0.0 0.057 8 Orientation: Back Window 3: Vinyl/Fiberglass Frame:Double Pane with Lo%A T 0.270 5 Orientation: Unspecified D E C E OVl Door 1: Solid v u v �r 0.300 6 Orientation: Unspecified Basement Wall 1: Solid Concrete or Masonry NOV 0 7 2017 1 0.0 15.0 0.044 7 Orientation: Front Wall height: 7.9' Depth below grade: 6.9' TOWN OF QUEENSBURY Insulation depth: 7.5' BUILDING&CODES Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 1 of10 Gross Area Cavity Cont. Perimeter Basement Wall 2:Solid Concrete or Masonry 150 0.0 15.0 0.044 7 Orientation: Right side Wall height: 7.9' Depth below grade: 6.9' Insulation depth: 7.5' Basement Wall 3: Solid Concrete or Masonry 158 0.0 15.0 0.044 7 Orientation: Back Wall height: 7.9' Depth below grade: 6.9' Insulation depth: 7.5' Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.3 and to comply with the mandatory requiremen ed i RE eck Inspection Checklist. Ethan Peter Hall-Architect Name-Title Sign _�iymo 8r .: Date J Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 2 of 10 REScheck Software Version 4.6.3 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Plan # Pre-Inspection/ Review Value Value Complies? Comments/Assumptions & Req.ID j 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the Location on plans/spec: building envelope.Thermal ❑Not Observable One envelope represented on []Not Applicable construction documents. 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for Location on plans/spec: [PR3]1 lighting and mechanical systems. []Not Observable One Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Location on plans/spec: Manual J or other methods Btu/hr Btu/hr ❑Not Observable One approved by the code official. ❑Not Applicable Additional Comments/Assumptions: j 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 3 of 10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.iD 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R- R- []Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies Requirement will be met. [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. []Not Observable Location on plans/spec: One []Not Applicable 402.2.9 Conditioned basement wall ft ft []Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or []Does Not table for values. �1 distance from top of wall. ❑Not Observable [:]Not Applicable 303.2.1 A protective covering is installed ❑Complies Exception: Requirement is [FO11]2 to protect exposed exterior ❑Does Not not applicable. insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is [FO12]2 controls installed. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 4 of 10 LSection Plans Verified Field Verified # Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions & Req.ID _ '402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 1 402.3.4 ❑Does Not table for values. I[FR1]1 []Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable Location on plans/spec: taken from the default table. One ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. Location on plans/spec: ❑Not Observable One ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC []Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies Exception: Requirement is [FR16]2 sealed at housing/interior finish ❑Does Not not applicable. and labeled to indicate<_2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies Exception: Ducts located [FR12]1 insulated >= R-8 where duct is ❑Does Not completely inside the >=3 inches in diameter and >= ❑Not Observable building envelope. R-6 where < 3 inches.Supply and return ducts in other portions of ❑Not Applicable the building insulated>= R-6 for diameter>= 3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable Location on plans/spec: One _ ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies Exception: Requirement is [FR17]2 above 105 QF or chilled fluids ❑Does Not not applicable. below 55 QF are insulated to >_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies Exception: Requirement is [FR24]1 piping. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met. [FR18]2 >R-3. []Does Not []Not Observable Location on plans/spec: ❑Not Applicable One 403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. Location on plans/spec: ❑Not Observable One ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 5 of 10 Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 6 of 10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/Z of the ❑ Wood ❑ Wood []Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [IN3]1 exterior,the exterior insulation ❑Not Observable ❑ Steel Steel requirement applies(FR10). ee ❑ ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable Location on plans/spec: ❑Not Applicable One Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename:Y:\Honey-Do Man\Blake Addition\Blake.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Recl.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, Wood ❑ Wood ❑Does Not table for values. 402.2.2, Steel ❑ Steel ❑Not Observable 402.2.6 ,[Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per T ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every ❑Not Observable Location on plans/spec: 300 2 One ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies Requirement will be met. [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Nt Observable Location on plans/spec: oservae extends over insulation. One ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [F13]1 insulation>_R-value of the ❑Does Not adjacent assembly. []Not Observable Location on plans/spec: One ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. Location on plans/spec: ❑Not Observable One ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air [1714]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not handlers are located within <=3 cfm/100 ft2 without air conditioned space. handier @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable _occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air [F127]1 determine air leakage with ft2 ft2 ❑Does Not handlers are located within either: Rough-in test:Total conditioned space. leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handier enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handier enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable Location on plans/spec: - One ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [F19]2 installed for control of primary ❑Does Not heating and cooling systems and Location on plans/spec: initially set by manufacturer to ❑Not Observable One code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies Exception: Requirement is [F11112 systems have automatic or ❑Does Not not applicable. accessible manual controls. []Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions Value ValueComplies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies Requirement will be met. [F125]2 fans not part of tested and listed ❑Does Not t HVAC equipment meet efficacy Location on plans/spec: i and air flow limits. ❑Not Observable ❑ One s Not Applicable `403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [FI26]2 through one-or two-pipe heating ❑Does Not not applicable. systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor []Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies Exception: Requirement is (F128]2 have a circulation pump.The ❑Does Not not applicable. system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [FI29]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [F130]2 have recirculation pumps that ❑Does Not not applicable. pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies Requirement will be met. [FI31]2 tested in accordance with CSA []Does Not 855.1. Potable water-side ❑Not Observable Location on plans/spec: pressure loss of drain water heat One recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies Requirement will be met. [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. (:]Not Observable Location on plans/spec: Does not apply to low-voltage One lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename: Y:\Honey-Do Man\Blake Addition\Blake.rck Page 9 of 10 Section Pians Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.iD 401.3 Compliance certificate posted. ❑Complies Requirement will be met. [F17]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI1B]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 TLow Impact(Tier 3) Project Title: New Addition Report date: 11/06/17 Data filename:Y:\Honey-Do Man\Blake Addition\Blake.rck Page 10 of 10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating . Window 0.27 Door 0.30 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date• Comments