Loading...
RC-000705-2017 _ TOWN QU NS U EE B RY ,� . 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000705-2017 Date Issued: Tuesday, March 6, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000705-2017 has been completed. Tax Map Number: 308.12-1-42 Location: 10 WOODEN LN Owner: Michaels Group Homes, LLC Applicant: Michaels Group Homes, LLC This structure may be occupied as a: SFD w/gas FP 1,660 sq. ft. Garage 466 s.f. By Order of Town Board Laric Development-Lot 17 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000705-2017 Tax Map No: 308.12-1-42 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 10 WOODEN LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvne of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $280,000.00 Owner Address: 1 Marions Way Total Value $280,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marions Way Mechanicville,NY 12118 Plans&Specifications SFD w/gas FP 1,660 sq.ft. Garage 466 s.f. Laric Development-Lot 17 $1,301.90 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,November 19,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date) Dated at the Tor7QP *emb er 17,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PREqCIPA: STRUCTURE .PLICATION � Office Use Onlv Date: IoI3�1 11 1-7 . i Perm it No. Re—' -7d J ",;Lo axx Map ID Zone Historic? Yes No ( Rec Feea7, � Site Plan# Subdivision Name 9j,7- -T , ��_ � a ) Lot# Subdivision m Project Location ip vk:bO�S ��� I TOWN BD.RESOLUTION$6-2013: $aso recreation fee for new dwelling units—single family,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). PrimarvOwner(s) Address t�j1 c�.1 S 1•-i -�, ���J l , �i>a' 1 Z 13 Phone/Email Applicant Address D Pnone/Email Nnv n R 7.. —4 Contractor � SA-wtc �-� lk�,�=- , TOWN DE nUEEN��I�RY Address COMMUNITY DEVELOPMENT Phone/Email Contact Person for Building&Codes Compliance: Phone c6 S-) .S14 4- TYPE OF CONSTRUICTION 1 s ✓Check all that apply New Addition Alteration ; Pt floor sf 2nd floor sf E Total sf HQlght 1 Single Family A�c � 1�b(dC>l�t 1��� 23�t/� Two-Far-nily 4 i Multi-Family i t I � I k#of units Townhouse C ` Business Office { Retail-.Mercantile Factory-Industrial I I I Attached Garage 4&,e, f I (1� 4`) ! Other i Town of Queensburl Building&Codes Principal Structure Application revised lanuarf 2016 ! If commercial or industrial please indicate name of business -,Proposed use of building or addition Source of Feat(circle one) a Oil Propane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? Are there easements on the property? t p Site Information: a. Dimensions or acreage of lot b. Is this a comer lot? Yes �( No c. Will the grade be changed as a result of construction `Ces No d. Public water or Private well(circle one) ePublic Private e. Sewer or Private Septic System (circle one) Sewerrivate Value of all work to be performed (labor or materials) $ z 919, U o0 DECLARA 1. I acknowledge no construction shah erm be commenced prior to issuance of a valid per and will be completed-within a 12 month period. 2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and department approval. I I certify that the application, plans and supporting materials are a true and complete statement 1 description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I/we are rewired to provide an as-built surrey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NA_NE: v,-� o� o C. ALL DATE: -& 7 SIGNAT"U' E: DATE: For office use onky {operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel urn.ing Appliance & Chimney Ap ` ation Office Use Only E .6 DATE: ct-7 T TAx INLAP ID: Pe Nov 0 8 20 ?Pe e ZONE: TOWN OF QUEENSgURY CO OWNER ADDRESS j we zl INSTALLER/ I P,4 p ' PHONE/E-MAIL BUILDER CONTACT PERSON FOR BUILDNG&CODE COMPLIANCE: LCOC.ASC)0 PHONE/E-MAIL 51&•$�7 - -y 4 4 $UILDNG ADDRESS IC> ROOM OF INSTALL: 1_i ill iscg PLANNED INSTALL DATE: FUEL BURNING APPLIANCE NFORVLATION WOOD COAL PELLET E GAS OIL NOTE• ROUsE-IN& i STOVE FINAL INSPECTION ARE I I FIREPLACE INSERT l REQUIRED. � I FIREPLACE,FACTORY BUILT` I X I NOTE: FIREPLACE,MASONRY MANUFACTURER'S t � i INSTALLATION MANUAL 1 FURNACE(GARAGE ONLY) E I MUST BE AVAILABLE AT TIME OF INSPECTION i *If factory built provide manufacturer name: -1 -�4-Cj L g, ; Model#: Listed by: Number: L7 CHIMNEY INFORMATION I Masonry** (check one) j BLOCK $RICK STONE i Flue TIE STEEL Size in inches ; Material f DOUBLE WALL _TRIPLE WALL NSULATED ** If non-masonry provide manufacturer name: ; Model#: DECLARATION: COnstruction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE REAR ANIS AGREE TO THE ABOVE: PRR4'TN4L�ME: 20 Z,'4f4ADATE: / SIGNATURE: , DATE: -2 Town of I<ueensbur r Build'€n�&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only j • Received • DATE: Tax Map ID TA,Y MAP ID: Permit No. ZONE: Permit Fee APPLICANT 1`� C -i 0�'a`t� �ZC.�.�� 3-lC��..i,�S, L-L.c PHONE/E-MAIL ADDRESS 1 M,4tz�o�eS titA�f, Nf�2t#�cW1LV t Ll:t', jlY 17-tt® INSTALLER/ C�-1 b.�ZLtS F21�t�i1�.�V1C�Jk�Y1S�Tl1 PHONE/E-MAIL BUILDER {OWNER ( t�tt.}�fk+cl.� �jztys,� 1-iGM�S ,t.d � 5klb ,gc,y .to3)s ADDRESS 1d = 1 pt'�vsz�s CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: T-0 VY UL)L gk'E>� PHONE/E-MAIL c&67 •314 4- RESIDENCE RESIDENCE INF'ORMATION Year Built A of bedrooms X gallons per bedroom j =fatal Daily flow 1980 or older Garbage grin-der installed —Yes _oto I 1981-1991 i I Spa or Hot Tub installed _Yes ,XNo 1992-Present w O 3 Q PARCEL INFORM IATION i Topography _-,\,Clat rolling Steep slope _%Slope Soil Nature X Sand Loam Clay Other i Groundwater At what depth: Bedrock/Impervious material At what depth: G4 Domestic'Water Supply I Municipal Well(if welt,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEi4t FOR NEW CONSTRUCTION Tank size 000 gallons(zein.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub System Absorption field with 42 stone Total length7 o ft.;Each Trench_ Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type. Holding Tank System Total required capacity? Tank size 4 of tanks Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2;We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file–no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and all requirements of the Town of Q een bury Sanitary Sewage Disposal Ordinance. PRINT NAME: A4--/ –r- 7. (&I-S(A) DATE: SIGNATE RE: DA<T E: / Town of Queensbury Building Ccdes Principal Strzcoure Application Revised January 20I6 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent —142 Bay Road, Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: t 0�D) 1"7 Applicant Name: Telephone No.: 5N"'21) Address to be Inspected 1 C7� Return Address: 1 M r—s akot.1 s Applicant must show exact Iocation and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: { ) Preliminary approval NEED ( ) Slight Swale { } Deep Swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Ippon completion please resubmit this approval permit for a final approval. STEP 2: { ) Final Approval ( } Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 20 ib SEPTIC PLOT PLAN I HAVE SEEN OR OBSERVED ALL OBJECTS M Z 0 S Nov U 8 2017 SUCH AS HOUSES, WE LS, TREES, FENCES, ETC _.--- SHOWN ON T DO ENT.I HAVE PERS NAL Y TOWN OF QUEENSBURY MEASURED DIT E SET FORTH ON THIS DI RA C MMUNITY DEVELOPMENT L .JO SI N R A Cl) L _ LO N co o M 9Z,61 0 6L N 8 Cl) s Co. c \ 09 r i o Nyo N /rl��ti r 308.12-1-42 RC-000705-2017 Michaels Group 10 Wooden Lane ` SFD w/FP 1660 s.f., Garage 466 s.f. REScheck Software Version 4.6.2 Compliance Certificate D C E o d NOV 0 8 2011 Project The Hawthorn TOWN OF QUEENSBURY COMMUNITY DEVELOPMENT Energy Code: 2015 IECC Location: Warren County, New York Construction Type: Single-family Project Type: New Construction 308.12-1-42 RC-000705-2017 Conditioned Floor Area: 1,660 ft2 Michaels Group Glazing Area 14% Climate Zone: 6 (8499 HDD) 10 Wooden Lane Permit Date: 26 October, 2017 SFD W/FP 1660 s.f., Garage 466 s.f. Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 10 Wooden Lane Michaels Group Homes, LLC Queensbury, NY 1 Marions Way Mechanicville, NY Compliance:Passes using UA trade-off Compliance: 4.4%Better Than Code Maximum UA: 274 Your UA: 262 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Assembly Gross Area Cavity Cont. Perimeter Ceiling: Raised or Energy Truss 1,660 0.0 38.0 0.025 42 Walls: Wood Frame, 24" o .c. 1,728 21.0 0.0 0.056 82 Entry#1: Solid 21 0.170 4 1x Bed #2 (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 Ix Bath (AA): Vinyl Frame:Double Pane with Low-E 5 0.300 2 1x Bed #3 (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 2x Dining (B):Vinyl Frame:Double Pane with Low-E 20 0.300 6 Dining #7: Glass 40 0.300 12 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9 1x Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8 1x Master Bed (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 1x Master Bath (AM): Vinyl Frame:Double Pane with Low-E 7 0.300 2 Mud #20: Solid 19 0.170 3 Basement Walls: Solid Concrete or Masonry 1,459 0.0 19.0 0.039 56 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' 2x Std Bsmt Win: Vinyl/Fiberglass Frame:Double Pane with Low-E 4 0.300 1 Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 1 of10 Gross Area Assembly or Cavity Cont. U-Factor UA 1x 5030 Sliding Window: Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.300 5 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. A Name-Title �[ Signature Date �wr Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review 1 Value Value Complies? 1 Comments/Assumptions do Req.ID i E 103.1, Construction drawings and ❑Complies ;103.2 documentation demonstrate ❑Does Not 1[PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. ---- --- ----.--_---------- 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable [PR3]1 lighting and mechanical systems. Systems serving multiple []Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. ;302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 1403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual] or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 3 of 10 Section Plans Verified Field Verified S7 Comments/Assumptions & Req.ID 1402.1.1 Conditioned basement wall R- R- ❑Complies Seethe Envelope Assemblies [FO411 insulation R-value. Where interior R R_ ❑Does Not table for values. insulation is used, verification 5 ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 1 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. -2" ❑Not Observable ❑Not Applicable 303.1 2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not `` insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 4 of 10 j Section Plans Verified Field Verified & Re ID Framing/Rough-In Inspections Value Value Complies? Comments/Assumptions q• 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 . , ❑Not Observable _ ❑Not Applicable ;402.1.1, Glazing U factor(area weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ;402.3.6, ❑Not Observable 1402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies I[FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. - ❑Not Applicable 1402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not to instructions. ❑Not Observable — ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 1403.3.3.5 Building cavities are not used as ❑Complies IFR 15]3 ducts or plenums. ❑Does Not ' ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 °F or chilled fluids ❑Does Not below 55 9F are insulated to >_R- [:]Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable -_.._..-_--__---- 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are - ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 5 of 10 Additional Comments/Assumptions: 1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 6 of 10 l Section Plans Verified Field Verifled # ! Insulation Inspection Value ValComplies? ! Comments/Assumptions ue & Req.ID i 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. [-]Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood F-1 Wood ❑Does Not table for values. ;402.2.6 wall insulation on the wall (IN-311 exterior,the exterior insulation ❑ Mass Mass ❑Not Observable requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. []Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 7 of 10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req,ID - 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, :402.2.6 E] Steel ❑ Steel ❑Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F1211 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable ;402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F1311 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable =402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F1411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to []Not Applicable occur during Framing Inspection. ;403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F12711 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g, across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F12411 by manufacturer at<=2%of []Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable ;403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI 1112 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact--(Tier-1) —2-Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 8 of10 Section i Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions & Req.ID j ( Value Value 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and airflow limits. :, ❑Not Applicable 403.2 Hot water boilers supplying heat u❑Complies [F126]2 through one-or two-pipe heating �❑ systems have outdoor setback Does Not control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems areMin not present. Controls for I circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold : ❑Not Applicable water supply pipe have a x ry demand recirculation water ' system. Pumps have controls that manage operation of the s pump and limit the temperature Iof the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat , ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water j heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ' ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions & Req.ID Value Value !401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for Com plies [F118]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2]- Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 10/26/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 10 of 10 1 2015 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments TI 10 Wooden Lane HVAC Load Calculations for The Michaels Group D IE C fZ Rn E NOV 082017 COMMUNITY DEVELOPMENT RIgslDeNTIA4 R H- ,_' HVAC L LAD s 308.12-1-42 RC-000705-2017 Michaels Group 10 Wooden Lane SFD w/FP 1660 s.f., Garage 466 s.f. Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Friday, October 27,2017 i I Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. App6ivo'Heating Inc. 10 Wooden Lane Schenectady, NY 12306 Project Report General Project Information Project Title: 10 Wooden Lane Designed By: The Michaels Group Project Date: Thursday, August 31, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data Reference City: Schenectady, New York Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check_Figures Total Building Supply CFM: 901 CFM Per Square ft.: 0.260 Square ft. of Room Area: 3,469 Square ft. Per Ton: 1,873 Volume (ft'): 29,404 (Building Loads Total Heating Required Including Ventilation Air: 49,501 Btuh 49.501 MBH Total Sensible Gain: 19,551 Btuh 88 % Total Latent Gain: 2,678 Btuh 12 % Total Cooling Required Including Ventilation Air: 22,229 Btuh 1.85 Tons (Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appofo'Heating Inc. 10 Wooden Lane Schenectady,_NY 12306 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb__ _Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs --- - - Main Trunk Runouts Calculate Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in,wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min i Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.280 AC/hr 0.150 AC/hr 137 CFM 74 CFM Infiltration Actual: 0.280 AC/hr 0.150 AC/hr Above Grade Volume: X 29,404 Cu.ft. X 29.404 Cu.ft. 8,233 Cu.ft./hr 4,411 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 137 CFM 74 CFM Total Building Ventilation: 0 CFM 0 CFM I ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr(137 CFM), Construction: Average Summer Infiltration Specified: 0.150 AC/hr(74 CFM), Construction: Average C:\Users\nicks\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM - - - - - ---- -- - Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. App-olo'Heating Inc. 10 Wooden Lane Schenectady, NY 12306 Page 4 Load Preview Report Mi Min Sysl Sys Sys Net ft. Sen La. Ne Sen Duc Htgl Clg Htgl Clg Act! Scope To /To Are Gal at Gai Loss Size _ CFMI CFM Ys CFM CFML ... Building 1.85 1,873 3,469 19,551 2,678 22,229 49,501 652 901 652 901 901 System 1 1.85 1,873 3,469 19,551 2,678 22,229 49,501 652 901 652 901 901 10x1 Zone 1 3,469 19,551 2,678 22,229 49,501 652 901 652 901 901 10x1 1-Dining/Kitchen 356 2,407 182 2,589 7213 95 111 95 111 111 2-4 2-Great Room 432 2,459 84 2,543 6,399 84 113 84 113 113 2 3-Bedroom 3 164 2,431 355 2,786 2,972 39 112 39 112 112 2 4-Bath 1 64 795 33 828 1,282 17 37 17 37 37 1 5-Bedroom 2 198 2,485 478 2,963 5,236 69 115 69 115 115 2 6-Foyer 110 915 73 988 2,333 31 42 31 42 42 1 7-Mud Room 70 665 33 698 1,369 18 31 18 31 31 1 8-Master Bedroom 221 2,799 738 3,537 4,825 64 129 64 129 129 2- 9-WIC 62 602 46 648 1,314 17 28 17 28 28 1 10-Master Bath 128 1266 93 1,359 2,862 38 58 38 58 58 1 11-Basement 1,665 2,729 563 3292 13,696 180 126 180 126 126 2-5 C:\Users\nicka\Docurnents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. ' Appolo•Heating Inc. 10 Wooden Lane Schenectady, NY 12306 Page 5 !. Duct Size Preview - -- - - Room or Source Minimum Maximum Roughl Desi grr��I SID Duct Duc Htg I Cig Act. Duct Duct Name Velocity Velocity Facto U10tl Loss Velocity Lengt_ Flow J Flow Flow Size System 1 Supply Runouts Zone 1 1-Dining/Kitchen Built-In 450 750 0.01 0.1 635.5 95 111 111 2-d 2-Great Room Built-in 450 750 0.01 0.1 649.2 84 113 113 2-4 III 3-Bedroom 3 Built-In 450 750 0.01 0.1 641.7 39 112 112 2-4 4-Bath 1 Built-In 450 750 0.01 0.1 419.8 17 37 37 1 5-Bedroom 2 Built-In 450 750 0.01 0.1 656.1 69 115 115 2-4 6-Foyer Built-In 450 750 0.01 0.1 483.3 31 42 42 1-4 7-Mud Room Built-In 450 750 0.01 0.1 351.2 18 31 31 1-4 8-Master Bedroom Built-In 450 750 0.01 0.1 472.9 64 129. 129 2-5 9-WIC Built-In 450 750 0.01 0.1 317.9 17 28 28 1--4 10-Master Bath Built-in 450 750 0.01 0.1 668.3 38 58 58 1 11-Basement Built-In 450 750 0.01 0.1 461.1 180 126' 126 2- Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 763.1 652 901': 901 10x1 Summary System 1 Heating Flow: 652 Cooling Flow: 901 CAUsers\nicks\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appb-V Heating Inc. 1111111h0 10 Wooden Lane Schenectady NY 12306 _ Page 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 194.6 4,162 0 2,997 2,997 Pella Slider: Door-Slider 40.8 845 0 282 282 Front Door TMG: Door-TMG Entry 21 246 0 82 82 Fire Rated: Door-Fire Rated 21 246 0 82 82 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1506.2 6,756 0 1,203 1,203 cavity, no board insulation, siding finish, wood studs 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1099.8 6,905 0 1,852 1,852 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1804.3 3,238 0 2,205 2,205 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1542.3 11,793 0 2,050 2,050 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 262 2,164 0 377 377 on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1664.6 2,872 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide Subtotals for structure: 39,227 0 11,130 11,130 People: 4 1,200 1,600 2,800 Equipment: 0 0 0 Lighting: 1720 5,865 5,865 Ductwork: 0 0 0 0 j Infiltration: Winter CFM: 137, Summer CFM: 74 10,274 1,478 956 2,434 Ventilation: Winter CFM: 0, Summer C_FM: 0 0 0 0 0 Total Building Load Totals: 49,501 2,678 19,551 22,229 Check Figures Total Building Supply CFM: 901 CFM Per Square ft.: 0.260 Square ft. of Room Area: 3,469 Square ft. Per Ton: 1,873 Volume (ft'): 29,404 Building Loads Total Heating Required Including Ventilation Air: 49,501 Btuh 49.501 MBH Total Sensible Gain: 19,551 Btuh 88 % Total Latent Gain: 2,678 Btuh 12 % Total Cooling Required Including Ventilation Air: 22,229 Btuh 1.85 Tons (Based On Sensible+ Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM I Rhva Residential dential&Light Commercial HVAC Loads Elite Software Development,Inc. App6TAeating Inc. 10 Wooden Lane Schenectady,NY 12306 _ _ Pae 19 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg " Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Dining/Kitchen 356 7,213 95 2-4 636 2,407 182 111 111 2 Great Room 432 6,399 84 2-4 649 2,459 84 113 113 3 Bedroom 3 164 2,972 39 2-4 642 2,431 355 112 112 4 Bath 1 64 1,282 17 1-4 420 795 33 37 37 5 Bedroom 2 198 5,236 69 2-4 656 2,485 478 115 115 6 Foyer 110 2,333 31 1-4 483 915 73 42 42 7 Mud Room 70 1,369 18 1-4 351 665 33 31 31 8 Master Bedroom 221 4,825 64 2-5 473 2,799 738 129 129 9 WIC 62 1,314 17 1-4 318 602 46 28 28 10 Master Bath 128 2,862 38 1-4 668 1,266 93 58 58 11 Basement 1,665 13,696 180 2-5 461 2,729 563 126 126 System 1 total _ 3,469 49,501 652 19,551 2,678 901 901 System 1 Main Trunk Size: 10x17 in. Velocity: 763 ft./min Loss per 100 ft.: 0.096 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.85 88%/ 12% 19,551 2,678 22,229 Actual: 2.33 75%/25% 21,000 7,000 28,000 Equipment Data Heating System Coolinct System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B* 13ACXN030-230-** Indoor Model: C35-30B"+TDR Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 28,000 Btuh Sensible Capacity: n/a 21,000 Btuh Latent Capacity: n/a 7,000 Btuh AHRI Reference No.: n/a 8736592 C:\Users\nicks\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM Map Reference: = Map of a Proposed Subdivision Made For Laric Development, LLC Dated April 10, 2003 Last Revised.January 4, 2014 By: Van Dusen & Steves Filed: March 3, 2014, Plat C-349 Nr 156a 23 96 Q 1 3t LOf 8 a5 \y1110-1 " '1-4wv y to Gas Meter 5�o me N 96x- � dFra Jg� Electric Meter �J.JOo lJ� Lot 17 Area 52713.3± Sq. Feet 1.2± Acres \Nti o Np s w X82.64' CAI N 79°7=6„ w 0 as LOf 16Cn N sr _ w 66-32 m wMAR 0 2 2018 ° 9" S �5FINAL S ' DO TOWN OF QUEENSBURY ,� � BUILDING&CODES LAND 5 Bate, F ebruary 21, 2018 Du S •UNAUTHGIr17ED ALTERATION DR ADDITION TO A suRvev Map of a Survey made for SCQte 1'=30' YAP BEARING A LICENSED LAND SURVEYORS SEAL IS A v wa D„ .AnoN of SECTION 7209,SUB-DIVISION 2,OF n & NEW YORK STATE EDUCATION LAW.• ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIOINAL OF THE LAND SURVEYORS evesSHALL BECONSIDERED T°BEVALID Es Michaels Group Homes S- 1 'CERTIFICATIONS INDICATED HEREON SN.16FY THAT P THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE Land Surveyors EL��`�RS. CER M SH�RU ONLY OPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL TO THE PERI.M FOR WHOM THE SURVEY IS PREPARED,AND SHEET 1 OF 1 ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL New York 12804 AGENCY AND LENDING INSTITUTION USIED HEREON,AND Town of Queensbury, Warren County, New York 169 Haviland Road Queensbury, TG THE ASSIGNEES OF THE LENDING INSTITUTION' Michaels Group Homes (518) 792-8474 New York Lie. No. 50135 NO. DATE , DESCRIPTION DWG. NO. 99-241 Lot 17