CERTIFICATE OF OCCUPANCY
Permit Number: RC-000705-2017 Date Issued: Tuesday, March 6, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000705-2017
has been completed.
Tax Map Number: 308.12-1-42
Location: 10 WOODEN LN
Owner: Michaels Group Homes, LLC
Applicant: Michaels Group Homes, LLC
This structure may be occupied as a: SFD w/gas FP 1,660 sq. ft.
Garage 466 s.f. By Order of Town Board
Laric Development-Lot 17 TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: RC-000705-2017
Tax Map No: 308.12-1-42
Permission is hereby granted to: Michaels Group Homes,LLC
For property located at: 10 WOODEN LN
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Tvne of Construction
Owner Name: Michaels Group Homes,LLC Single Family-New $280,000.00
Owner Address: 1 Marions Way Total Value $280,000.00
Mechanicville,NY 12118
Contractor or Builder's Name/Address Electrical Inspection Agency
Michaels Group Homes,LLC
1 Marions Way
Mechanicville,NY 12118
Plans&Specifications
SFD w/gas FP 1,660 sq.ft.
Garage 466 s.f.
Laric Development-Lot 17
$1,301.90 PERMIT FEE PAID-THIS PERMIT EXPIRES: Monday,November 19,2018
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date)
Dated at the Tor7QP
*emb er 17,2017
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
PREqCIPA: STRUCTURE .PLICATION � Office Use Onlv
Date: IoI3�1 11 1-7
. i Perm it No. Re—' -7d J ",;Lo
axx Map ID
Zone Historic? Yes No ( Rec Feea7,
� Site Plan#
Subdivision Name 9j,7- -T , ��_ � a ) Lot# Subdivision m
Project Location ip vk:bO�S ��� I
TOWN BD.RESOLUTION$6-2013: $aso recreation fee for new dwelling units—single family,duplexes/two-family,multiple family,
apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the
permit fee(s).
PrimarvOwner(s)
Address t�j1 c�.1 S 1•-i -�, ���J l , �i>a' 1 Z 13
Phone/Email
Applicant
Address D
Pnone/Email Nnv n R 7..
—4
Contractor � SA-wtc �-� lk�,�=- ,
TOWN DE nUEEN��I�RY
Address COMMUNITY DEVELOPMENT
Phone/Email
Contact Person for Building&Codes Compliance: Phone c6 S-) .S14 4-
TYPE OF CONSTRUICTION 1
s ✓Check all that apply New Addition Alteration ; Pt floor sf 2nd floor sf E Total sf HQlght 1
Single Family A�c � 1�b(dC>l�t 1��� 23�t/�
Two-Far-nily 4
i
Multi-Family i
t
I � I
k#of units
Townhouse
C
` Business Office
{ Retail-.Mercantile
Factory-Industrial
I I
I
Attached Garage 4&,e,
f
I (1� 4`)
! Other i
Town of Queensburl Building&Codes Principal Structure Application revised lanuarf 2016
! If commercial or industrial please indicate name of business
-,Proposed use of building or addition
Source of Feat(circle one) a Oil Propane Solar Other
Fireplace: Complete a separate application for Fuel Burning
Appliances & Chimneys
Are there structures not shown on plot plan?
Are there easements on the property? t p
Site Information:
a. Dimensions or acreage of lot
b. Is this a comer lot? Yes �( No
c. Will the grade be changed as a result of construction `Ces No
d. Public water or Private well(circle one) ePublic Private
e. Sewer or Private Septic System (circle one) Sewerrivate
Value of all work to be performed (labor or materials) $ z 919, U o0
DECLARA
1. I acknowledge no construction shah erm
be commenced prior to issuance of a valid per and will be
completed-within a 12 month period.
2. If work is not complete by the 1 year expiration date the permit may be renewed, subject to fees and
department approval.
I I certify that the application, plans and supporting materials are a true and complete statement 1
description of the work proposed, that all work will be performed in accordance with the NYS
Building Codes, local building laws and ordinances,and in conformance with local zoning regulations
4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate
of occupancy.
5. I also understand that I/we are rewired to provide an as-built surrey by a licensed land surveyor of
all newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NA_NE: v,-� o� o C. ALL DATE: -& 7
SIGNAT"U' E: DATE:
For office use onky
{operating Permit Issued: Yes No
Occupancy Type
Construction Classification
Assembly Occupancy Limit
Special Conditions
Town of Queensbury Building&Codes Principal Structure Application Revised January 2016
Fuel urn.ing Appliance & Chimney Ap ` ation Office Use Only E
.6
DATE: ct-7 T
TAx INLAP ID: Pe
Nov 0 8 20 ?Pe e
ZONE:
TOWN OF QUEENSgURY
CO
OWNER
ADDRESS j we zl
INSTALLER/ I P,4 p ' PHONE/E-MAIL
BUILDER
CONTACT PERSON FOR BUILDNG&CODE COMPLIANCE: LCOC.ASC)0
PHONE/E-MAIL 51&•$�7 - -y 4 4
$UILDNG ADDRESS IC>
ROOM OF INSTALL: 1_i ill iscg PLANNED INSTALL DATE:
FUEL BURNING APPLIANCE NFORVLATION WOOD COAL PELLET E GAS OIL NOTE• ROUsE-IN&
i STOVE FINAL INSPECTION ARE I
I
FIREPLACE INSERT l REQUIRED.
� I
FIREPLACE,FACTORY BUILT` I X I NOTE:
FIREPLACE,MASONRY MANUFACTURER'S
t �
i INSTALLATION MANUAL
1 FURNACE(GARAGE ONLY) E I
MUST BE AVAILABLE AT
TIME OF INSPECTION
i *If factory built provide manufacturer name: -1 -�4-Cj L g, ; Model#:
Listed by: Number: L7
CHIMNEY INFORMATION
I Masonry** (check one) j BLOCK $RICK STONE
i Flue TIE STEEL Size in inches ;
Material f DOUBLE WALL _TRIPLE WALL NSULATED
** If non-masonry provide manufacturer name: ; Model#:
DECLARATION: COnstruction/installation must conform to NYS Fire Prevention & Building Code and/or
manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances,
regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises
to perform required inspections.
I HAVE REAR ANIS AGREE TO THE ABOVE:
PRR4'TN4L�ME: 20 Z,'4f4ADATE: /
SIGNATURE: ,
DATE: -2
Town of I<ueensbur r Build'€n�&Codes Principal Structure Application Revised January 2016
SEPTIC DISPOSAL APPLICATION Office Use Only j
• Received
• DATE: Tax Map ID
TA,Y MAP ID: Permit No.
ZONE: Permit Fee
APPLICANT 1`� C -i 0�'a`t� �ZC.�.�� 3-lC��..i,�S, L-L.c PHONE/E-MAIL
ADDRESS 1 M,4tz�o�eS titA�f, Nf�2t#�cW1LV t Ll:t', jlY 17-tt®
INSTALLER/ C�-1 b.�ZLtS F21�t�i1�.�V1C�Jk�Y1S�Tl1 PHONE/E-MAIL
BUILDER
{OWNER ( t�tt.}�fk+cl.� �jztys,� 1-iGM�S ,t.d � 5klb ,gc,y .to3)s
ADDRESS 1d = 1 pt'�vsz�s
CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: T-0 VY UL)L gk'E>�
PHONE/E-MAIL c&67 •314 4-
RESIDENCE
RESIDENCE INF'ORMATION
Year Built A of bedrooms X gallons per bedroom j =fatal Daily flow
1980 or older Garbage grin-der installed —Yes _oto I
1981-1991 i I Spa or Hot Tub installed _Yes ,XNo
1992-Present w O 3 Q
PARCEL INFORM IATION
i
Topography _-,\,Clat rolling Steep slope _%Slope
Soil Nature X Sand Loam Clay Other
i
Groundwater At what depth:
Bedrock/Impervious material At what depth: G4
Domestic'Water Supply I Municipal Well(if welt,water supply from any septic system absorption is_ft.)
Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect)
PROPOSED SYSTEi4t FOR NEW CONSTRUCTION
Tank size 000 gallons(zein.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tub
System Absorption field with 42 stone Total length7 o ft.;Each Trench_
Seepage Pit with#3 stone How many: ;Size
Alternative System Bed or other type.
Holding Tank System Total required capacity? Tank size 4 of tanks
Notes: 1)Alarm system& associated electrical work must be inspected by a Town approved electrical inspection agency;2;We will
no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the
septic system layout on file–no exceptions.
Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure
to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to
abide by these and all requirements of the Town of Q een bury Sanitary Sewage Disposal Ordinance.
PRINT NAME: A4--/ –r- 7. (&I-S(A) DATE:
SIGNATE RE: DA<T E: /
Town of Queensbury Building Ccdes Principal Strzcoure Application Revised January 20I6
Town of Queensbury Thomas R. Van Ness
Highway Department Highway Superintendent
—142 Bay Road, Queensbury,NY 12804 Home: 518-745-0929
Phone: 518-761-8211
Fax: 518-745-4466 David Duell
Deputy Highway Superintendent
Home: 518-745-0938
DRIVEWAY PERMIT
Date: t 0�D) 1"7
Applicant Name:
Telephone No.: 5N"'21)
Address to be Inspected 1 C7�
Return Address: 1 M r—s akot.1 s
Applicant must show exact Iocation and width of driveway(s)to be connected to the highway by placing stakes
at the specified location
The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action
has been taken:
STEP 1: { ) Preliminary approval
NEED ( ) Slight Swale
{ } Deep Swale
( ) Level with the road
( ) Level with the top of the paved wing
Size culvert pipe to be used (if necessary)
( ) 12" ( ) 15" ( ) 18" ( ) 24" ( 36"
Preliminary inspection completed by: Date:
Approval by Highway Supt.: or Deputy Supt.:
Ippon completion please resubmit this approval permit for a final approval.
STEP 2: { ) Final Approval ( } Rejected
Date:
Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent
Town of Queensbury Building&Codes Principal Structure Application Revised January 20 ib
SEPTIC PLOT PLAN
I HAVE SEEN OR OBSERVED ALL OBJECTS M Z 0 S Nov U 8 2017
SUCH AS HOUSES, WE LS, TREES, FENCES, ETC _.---
SHOWN ON T DO ENT.I HAVE PERS NAL Y TOWN OF QUEENSBURY
MEASURED DIT E SET FORTH ON THIS DI RA C MMUNITY DEVELOPMENT
L .JO
SI N R A
Cl)
L _
LO
N
co
o
M 9Z,61 0 6L N
8 Cl)
s
Co. c \
09
r
i
o
Nyo
N /rl��ti
r
308.12-1-42 RC-000705-2017
Michaels Group
10 Wooden Lane `
SFD w/FP 1660 s.f., Garage 466 s.f.
REScheck Software Version 4.6.2
Compliance Certificate D C E o d
NOV 0 8 2011
Project The Hawthorn TOWN OF QUEENSBURY
COMMUNITY DEVELOPMENT
Energy Code: 2015 IECC
Location: Warren County, New York
Construction Type: Single-family
Project Type: New Construction 308.12-1-42 RC-000705-2017
Conditioned Floor Area: 1,660 ft2 Michaels Group
Glazing Area 14%
Climate Zone: 6 (8499 HDD) 10 Wooden Lane
Permit Date: 26 October, 2017 SFD W/FP 1660 s.f., Garage 466 s.f.
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
10 Wooden Lane Michaels Group Homes, LLC
Queensbury, NY 1 Marions Way
Mechanicville, NY
Compliance:Passes using UA trade-off
Compliance: 4.4%Better Than Code Maximum UA: 274 Your UA: 262
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Assembly Gross Area Cavity Cont.
Perimeter
Ceiling: Raised or Energy Truss 1,660 0.0 38.0 0.025 42
Walls: Wood Frame, 24" o .c. 1,728 21.0 0.0 0.056 82
Entry#1: Solid 21 0.170 4
1x Bed #2 (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10
Ix Bath (AA): Vinyl Frame:Double Pane with Low-E 5 0.300 2
1x Bed #3 (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10
2x Dining (B):Vinyl Frame:Double Pane with Low-E 20 0.300 6
Dining #7: Glass 40 0.300 12
2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9
1x Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8
1x Master Bed (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10
1x Master Bath (AM): Vinyl Frame:Double Pane with Low-E 7 0.300 2
Mud #20: Solid 19 0.170 3
Basement Walls: Solid Concrete or Masonry 1,459 0.0 19.0 0.039 56
Wall height: 7.6'
Depth below grade: 6.6'
Insulation depth: 7.6'
2x Std Bsmt Win: Vinyl/Fiberglass Frame:Double Pane with Low-E 4 0.300 1
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 1 of10
Gross Area
Assembly or Cavity Cont. U-Factor UA
1x 5030 Sliding Window: Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.300 5
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
A
Name-Title �[ Signature Date
�wr
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 2 of 10
REScheck Software Version 4.6.2
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-inspection/Plan Review 1 Value Value Complies? 1 Comments/Assumptions
do Req.ID i
E 103.1, Construction drawings and ❑Complies
;103.2 documentation demonstrate ❑Does Not
1[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
---- --- ----.--_----------
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for ❑Not Observable
[PR3]1 lighting and mechanical systems.
Systems serving multiple []Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
;302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
1403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
Manual] or other methods Btu/hr Btu/hr ❑Not Observable
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 3 of 10
Section Plans Verified Field Verified
S7 Comments/Assumptions
& Req.ID
1402.1.1 Conditioned basement wall R- R- ❑Complies Seethe Envelope Assemblies
[FO411 insulation R-value. Where interior R R_ ❑Does Not table for values.
insulation is used, verification
5 ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions. ❑Not Observable
❑Not Applicable
1 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO611 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
-2" ❑Not Observable
❑Not Applicable
303.1 2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
`` insulation and extends a ❑Not Observable
minimum of 6 in. below grade.
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[FO12]2 controls installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 4 of 10
j Section Plans Verified Field Verified
& Re ID Framing/Rough-In Inspections Value Value Complies? Comments/Assumptions
q•
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1
. , ❑Not Observable
_ ❑Not Applicable
;402.1.1, Glazing U factor(area weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
;402.3.6, ❑Not Observable
1402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies
I[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable
taken from the default table.
- ❑Not Applicable
1402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
to instructions.
❑Not Observable
— ❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_
R-6 where < 3 inches. Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
1403.3.3.5 Building cavities are not used as ❑Complies
IFR 15]3 ducts or plenums. ❑Does Not
' ❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105 °F or chilled fluids ❑Does Not
below 55 9F are insulated to >_R- [:]Not Observable
3.
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
-_.._..-_--__----
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are - ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 5 of 10
Additional Comments/Assumptions:
1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 6 of 10
l
Section Plans Verified Field Verifled
# ! Insulation Inspection Value ValComplies? ! Comments/Assumptions
ue
& Req.ID i
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided.
[-]Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the
❑ Wood F-1 Wood ❑Does Not table for values.
;402.2.6 wall insulation on the wall
(IN-311 exterior,the exterior insulation ❑ Mass Mass ❑Not Observable
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. []Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 7 of 10
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req,ID -
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2,
:402.2.6 E] Steel ❑ Steel ❑Not Observable
[Fill' ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F1211 Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable
;402.2.3 Vented attics with air permeable ❑Complies
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F1311 insulation >_R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
=402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F1411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests,verification may need to []Not Applicable
occur during Framing Inspection.
;403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F12711 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g, across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[F12411 by manufacturer at<=2%of []Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F19]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ❑Not Applicable
;403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
[FI 1112 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
1 High Impact--(Tier-1) —2-Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 8 of10
Section i Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
& Req.ID j ( Value Value
403.6.1 All mechanical ventilation system ❑Complies
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy ❑Not Observable
and airflow limits. :,
❑Not Applicable
403.2 Hot water boilers supplying heat u❑Complies
[F126]2 through one-or two-pipe heating �❑
systems have outdoor setback Does Not
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems areMin
not present. Controls for I circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[F129]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[F130]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated ❑Not Observable
water source through a cold : ❑Not Applicable
water supply pipe have a
x
ry
demand recirculation water '
system. Pumps have controls
that manage operation of the s
pump and limit the temperature
Iof the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat , ❑Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
j heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[FI6]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
' ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 9 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
& Req.ID Value Value
!401.3 Compliance certificate posted. ❑Complies
[FI7]2 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for Com plies
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2]-
Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Hawthorn Report date: 10/26/17
Data filename: F:\Share\Design\Res-Check\Burnt Ridge\10 Wooden Lane.rck Page 10 of 10
1
2015 IECC Energy
Efficiency Certificate
Insulation .
Above-Grade Wall 21.00
Below-Grade Wall 19.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.30
Door 0.30
CoolingHeating&
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments
TI
10 Wooden Lane
HVAC Load Calculations
for
The Michaels Group D IE C fZ Rn E
NOV 082017
COMMUNITY DEVELOPMENT
RIgslDeNTIA4
R H- ,_' HVAC L LAD s
308.12-1-42 RC-000705-2017
Michaels Group
10 Wooden Lane
SFD w/FP 1660 s.f., Garage 466 s.f.
Prepared By:
Nick Abrunza
Appolo Heating
868 Burdeck St
Schenectady Ny 12306
Friday, October 27,2017
i
I
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
App6ivo'Heating Inc. 10 Wooden Lane
Schenectady, NY 12306
Project Report
General Project Information
Project Title: 10 Wooden Lane
Designed By: The Michaels Group
Project Date: Thursday, August 31, 2017
Client Name: The Michaels Group
Company Name: Appolo Heating
Company Representative: Nick Abrunza
Company Address: 868 Burdeck St
Company City: Schenectady Ny 12306
Design Data
Reference City: Schenectady, New York
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 42 Degrees
Elevation: 378 ft.
Altitude Factor: 0.986
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 1 0.31 n/a n/a 70 n/a
Summer: 87 72 49% 50% 75 30
Check_Figures
Total Building Supply CFM: 901 CFM Per Square ft.: 0.260
Square ft. of Room Area: 3,469 Square ft. Per Ton: 1,873
Volume (ft'): 29,404
(Building Loads
Total Heating Required Including Ventilation Air: 49,501 Btuh 49.501 MBH
Total Sensible Gain: 19,551 Btuh 88 %
Total Latent Gain: 2,678 Btuh 12 %
Total Cooling Required Including Ventilation Air: 22,229 Btuh 1.85 Tons (Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appofo'Heating Inc. 10 Wooden Lane
Schenectady,_NY 12306 Page 3
Miscellaneous Report
System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains
Input Data Dry Bulb__ _Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 1 0.31 80% n/a 70 n/a
Summer: 87 72 49% 50% 75 29.96
Duct Sizing Inputs
--- - -
Main Trunk Runouts
Calculate Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in,wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min i
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration Specified: 0.280 AC/hr 0.150 AC/hr
137 CFM 74 CFM
Infiltration Actual: 0.280 AC/hr 0.150 AC/hr
Above Grade Volume: X 29,404 Cu.ft. X 29.404 Cu.ft.
8,233 Cu.ft./hr 4,411 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 137 CFM 74 CFM
Total Building Ventilation: 0 CFM 0 CFM
I
---System 1---
Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.280 AC/hr(137 CFM), Construction: Average
Summer Infiltration Specified: 0.150 AC/hr(74 CFM), Construction: Average
C:\Users\nicks\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM
- - - - - ---- -- -
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
App-olo'Heating Inc. 10 Wooden Lane
Schenectady, NY 12306 Page 4
Load Preview Report
Mi Min Sysl Sys Sys
Net ft. Sen La. Ne Sen Duc
Htgl Clg Htgl Clg Act!
Scope
To /To Are
Gal at Gai Loss Size
_ CFMI CFM Ys
CFM CFML ...
Building 1.85 1,873 3,469 19,551 2,678 22,229 49,501 652 901 652 901 901
System 1 1.85 1,873 3,469 19,551 2,678 22,229 49,501 652 901 652 901 901 10x1
Zone 1 3,469 19,551 2,678 22,229 49,501 652 901 652 901 901 10x1
1-Dining/Kitchen 356 2,407 182 2,589 7213 95 111 95 111 111 2-4
2-Great Room 432 2,459 84 2,543 6,399 84 113 84 113 113 2
3-Bedroom 3 164 2,431 355 2,786 2,972 39 112 39 112 112 2
4-Bath 1 64 795 33 828 1,282 17 37 17 37 37 1
5-Bedroom 2 198 2,485 478 2,963 5,236 69 115 69 115 115 2
6-Foyer 110 915 73 988 2,333 31 42 31 42 42 1
7-Mud Room 70 665 33 698 1,369 18 31 18 31 31 1
8-Master Bedroom 221 2,799 738 3,537 4,825 64 129 64 129 129 2-
9-WIC 62 602 46 648 1,314 17 28 17 28 28 1
10-Master Bath 128 1266 93 1,359 2,862 38 58 38 58 58 1
11-Basement 1,665 2,729 563 3292 13,696 180 126 180 126 126 2-5
C:\Users\nicka\Docurnents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
' Appolo•Heating Inc. 10 Wooden Lane
Schenectady, NY 12306 Page 5 !.
Duct Size Preview - -- - -
Room or Source Minimum Maximum Roughl Desi grr��I SID Duct Duc Htg I Cig Act. Duct
Duct Name Velocity Velocity Facto U10tl Loss Velocity Lengt_ Flow J Flow Flow Size
System 1
Supply Runouts
Zone 1
1-Dining/Kitchen Built-In 450 750 0.01 0.1 635.5 95 111 111 2-d
2-Great Room Built-in 450 750 0.01 0.1 649.2 84 113 113 2-4 III
3-Bedroom 3 Built-In 450 750 0.01 0.1 641.7 39 112 112 2-4
4-Bath 1 Built-In 450 750 0.01 0.1 419.8 17 37 37 1
5-Bedroom 2 Built-In 450 750 0.01 0.1 656.1 69 115 115 2-4
6-Foyer Built-In 450 750 0.01 0.1 483.3 31 42 42 1-4
7-Mud Room Built-In 450 750 0.01 0.1 351.2 18 31 31 1-4
8-Master Bedroom Built-In 450 750 0.01 0.1 472.9 64 129. 129 2-5
9-WIC Built-In 450 750 0.01 0.1 317.9 17 28 28 1--4
10-Master Bath Built-in 450 750 0.01 0.1 668.3 38 58 58 1
11-Basement Built-In 450 750 0.01 0.1 461.1 180 126' 126 2-
Other Ducts in System 1
Supply Main Trunk Built-In 650 900 0.003 0.1 763.1 652 901': 901 10x1
Summary
System 1
Heating Flow: 652
Cooling Flow: 901
CAUsers\nicks\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Appb-V Heating Inc. 1111111h0 10 Wooden Lane
Schenectady NY 12306 _ Page 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 194.6 4,162 0 2,997 2,997
Pella Slider: Door-Slider 40.8 845 0 282 282
Front Door TMG: Door-TMG Entry 21 246 0 82 82
Fire Rated: Door-Fire Rated 21 246 0 82 82
12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1506.2 6,756 0 1,203 1,203
cavity, no board insulation, siding finish, wood studs
12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1099.8 6,905 0 1,852 1,852
cavity, no board insulation, siding finish, wood studs
16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1804.3 3,238 0 2,205 2,205
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation
19A-Ocp: Floor-Over enclosed crawl space, No insulation 1542.3 11,793 0 2,050 2,050
on exposed walls, sealed or vented space, passive,
no floor insulation, carpet or hardwood
19A-Otp: Floor-Over enclosed crawl space, No insulation 262 2,164 0 377 377
on exposed walls, sealed or vented space, passive,
no floor insulation, tile or vinyl
21A-24: Floor-Basement, Concrete slab, any thickness, 2 1664.6 2,872 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 24'wide
Subtotals for structure: 39,227 0 11,130 11,130
People: 4 1,200 1,600 2,800
Equipment: 0 0 0
Lighting: 1720 5,865 5,865
Ductwork: 0 0 0 0
j Infiltration: Winter CFM: 137, Summer CFM: 74 10,274 1,478 956 2,434
Ventilation: Winter CFM: 0, Summer C_FM: 0 0 0 0 0
Total Building Load Totals: 49,501 2,678 19,551 22,229
Check Figures
Total Building Supply CFM: 901 CFM Per Square ft.: 0.260
Square ft. of Room Area: 3,469 Square ft. Per Ton: 1,873
Volume (ft'): 29,404
Building Loads
Total Heating Required Including Ventilation Air: 49,501 Btuh 49.501 MBH
Total Sensible Gain: 19,551 Btuh 88 %
Total Latent Gain: 2,678 Btuh 12 %
Total Cooling Required Including Ventilation Air: 22,229 Btuh 1.85 Tons (Based On Sensible+ Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM
I Rhva Residential dential&Light Commercial HVAC Loads Elite Software Development,Inc.
App6TAeating Inc. 10 Wooden Lane
Schenectady,NY 12306 _ _ Pae 19
System 1 Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg " Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Dining/Kitchen 356 7,213 95 2-4 636 2,407 182 111 111
2 Great Room 432 6,399 84 2-4 649 2,459 84 113 113
3 Bedroom 3 164 2,972 39 2-4 642 2,431 355 112 112
4 Bath 1 64 1,282 17 1-4 420 795 33 37 37
5 Bedroom 2 198 5,236 69 2-4 656 2,485 478 115 115
6 Foyer 110 2,333 31 1-4 483 915 73 42 42
7 Mud Room 70 1,369 18 1-4 351 665 33 31 31
8 Master Bedroom 221 4,825 64 2-5 473 2,799 738 129 129
9 WIC 62 1,314 17 1-4 318 602 46 28 28
10 Master Bath 128 2,862 38 1-4 668 1,266 93 58 58
11 Basement 1,665 13,696 180 2-5 461 2,729 563 126 126
System 1 total _ 3,469 49,501 652 19,551 2,678 901 901
System 1 Main Trunk Size: 10x17 in.
Velocity: 763 ft./min
Loss per 100 ft.: 0.096 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 1.85 88%/ 12% 19,551 2,678 22,229
Actual: 2.33 75%/25% 21,000 7,000 28,000
Equipment Data
Heating System Coolinct System
Type: Natural Gas Furnace Standard Air Conditioner
Model: ML195UH070XP36B* 13ACXN030-230-**
Indoor Model: C35-30B"+TDR
Brand: MERIT 90 LENNOX
Description: Natural Gas or Propane Furnace
Efficiency: 95 AFUE 13 SEER
Sound: 0 0
Capacity: 64,000 Btuh 28,000 Btuh
Sensible Capacity: n/a 21,000 Btuh
Latent Capacity: n/a 7,000 Btuh
AHRI Reference No.: n/a 8736592
C:\Users\nicks\Documents\Elite Software\Rhvac 9 Projects\10 Wooden Lane.rh9 Friday, October 27, 2017, 4:26 PM
Map Reference: =
Map of a Proposed Subdivision Made For
Laric Development, LLC
Dated April 10, 2003
Last Revised.January 4, 2014
By: Van Dusen & Steves
Filed: March 3, 2014, Plat C-349
Nr 156a
23
96
Q
1 3t
LOf 8
a5
\y1110-1
" '1-4wv
y
to
Gas Meter
5�o me N
96x- � dFra Jg�
Electric Meter �J.JOo lJ�
Lot 17
Area
52713.3± Sq. Feet
1.2± Acres
\Nti o Np
s w
X82.64'
CAI N 79°7=6„ w
0
as
LOf 16Cn
N
sr
_ w
66-32
m
wMAR 0 2 2018
°
9"
S �5FINAL S '
DO
TOWN OF QUEENSBURY ,� �
BUILDING&CODES
LAND 5
Bate, F ebruary 21, 2018
Du S •UNAUTHGIr17ED ALTERATION DR ADDITION TO A suRvev Map of a Survey made for SCQte 1'=30'
YAP BEARING A LICENSED LAND SURVEYORS SEAL IS A
v
wa
D„ .AnoN of SECTION 7209,SUB-DIVISION 2,OF n
& NEW YORK STATE EDUCATION
LAW.•
ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY
MARKED WITH AN ORIOINAL OF THE LAND SURVEYORS
evesSHALL BECONSIDERED T°BEVALID Es Michaels Group Homes S- 1
'CERTIFICATIONS INDICATED HEREON SN.16FY THAT P
THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE
Land Surveyors EL��`�RS. CER M SH�RU ONLY
OPTED
BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL
TO THE PERI.M FOR WHOM THE SURVEY IS PREPARED,AND SHEET 1 OF 1
ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL
New York 12804 AGENCY AND LENDING INSTITUTION USIED HEREON,AND Town of Queensbury, Warren County, New York
169 Haviland Road Queensbury, TG THE ASSIGNEES OF THE LENDING INSTITUTION' Michaels Group Homes
(518) 792-8474 New York Lie. No. 50135 NO. DATE , DESCRIPTION DWG. NO. 99-241 Lot 17