RC-000782-2017 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development-Building&Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: RC-000782-2017 Date Issued: Thursday, June 21, 2018
This is to certify that work requested to be done as shown by Permit Number RC-000782-2017
has been completed.
Tax Map Number: 278.-1-52
Location: 1269 BAY RD
Owner: Geof Hoffman, Cheryl Hoffinan
Applicant: Jerry Ryan
This structure may be occupied as a: Residential Addition 852 s.f.
Building on existing foundation By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan, jd
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: RC-000782-2017
Tax Map No: 278.-1-52
Permission is hereby granted to: Gauthier Skilled Craftsman,LLC
For property located at: 1269 BAY RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: Geof Hoffman Single Family-Addition $125,000.00
Owner Address: 1269 Bay RD Total Value $125,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Gauthier Skilled Craftsman,LLC
30 Delaware AVE
Hudson Falls,NY 12839
Plans&Specifications
Residential Addition 852 s.f.
Building on existing foundation
$ 170.40 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,January 17, 2019
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the xpiration dat .)
Dated at the Town o ueen kle anuary 17,2018
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
ADDITION/ALTERATION PERMIT c
ADDITION n rev —a c�
l Permit#: - - 7
APPLICATI Permit Fee: $ 70 • `I
Town of QueensburyE
742 Bay Road,Queensbury,NY 12804 D ll�D � US
P:518-761-8256 www.gueensbury.net
Project Location: DEC 18 ?017
5 BUIL N OF QUEENSSURY
Tax Map ID#•
CONTACT INFORMATION:
• ApplicantName(s): -1,1 .t
Mailing Address, C/S/Z: 3 �� �c.�.t` wt 4,,Z, F 11s, a y a?3S
Cell Phone: S (Y ) rL32-IS b 6 Land Line: S i 0-7 6 C1
Email: r c
• Primary Owner(s):
Name(s): e�Xv-ti 1 -t-Co-'s
Mailing Address, C/S/Z: CUC5 (�c.� {�� - ��, L_.' tilt Icy f—
Cell Phone: (( < 112 )3 V 7 -417_S Land Line: �)
Email: Un a Un-, 6 1? Q_ r-.,,, c c
• Contractor(s)•
Business Name: Cly.�,"'U S �c,���� 0�"(A s'_.'
Contact Name(s): G c
Mailing Address, C/S/Z: 0 De 4u-t . SUA F� S
oa ane,
Cell Phone: s1 ) —alt Land Line:
Email: secrn, c.r�✓�,trS�C�� Cry s a!� C�•,c.
u
• Architects En ineer s : _
Business Name: -CA LJ) 6)
Contact Name(s):
Mailing Address, C/S/Z: 14 S S
Cell Phone: !Q F +4-,4 4-1L Land Line: � )
Email: e ^�C-n
Contact Person for Building & Code Compliance: 67"t•U e��
Cell Phone: ( S iB ) ci 3 2.- I S 6 1 - Land Line:
Email: Je c i- ., g Cha r. .� ctr SSC e
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
PROJECT INFORMATION:
TYPE: Commercial Residential
WORK CLASS:
Single-Family Two-Family Multi-Family (#of units )
Townhouse Business Office Retail
Industrial/Warehouse Garage (# of cars ) _Other (describe )
ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE:
1st floor: 1st floor: 0 Z
2nd floor: X05k\,^ 2nd floor: 13o
3rd floor: 3rd floor:
4th floor: 41h floor:
Total square feet: Total square feet:
ADDITIONAL PROJECT INFORMATION:'
1. Estimated Cost of Construction: $
2. If Commercial project, what is the proposed use:
3. Source of Heat (circle one): Gas Oil Propane Solar Other
Fireplaces need a separate Fuel Burning Appliances & Chimney Application
4. Are there any structures not shown on the plot plan? YES NO Explain:
5. Are there any easements on the property? YES
6. SITE INFORMATION:
a. What is the dimensions or acreage of thecel?
b. Is this a corner lot? YES
c. Will the grade be changed as a result of the construct' ES
d. What is the water source? PUBLIC RIVATE [�
e. Is the parcel on SEWER or a PRIVATE SEPTIC system? l'C Svc`
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
DECLARATION:
L I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be
completed within a 12 month period.
2. If thework is not completed by the 1 year expiration date the permit may be renewed, subject to
fees and department approval.
3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or
description of the work proposed, that all work will be performed in accordance with the NYS Building
Codes, local building laws and ordinances, and in conformance with local zoning regulations.
4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate
of occupancy.
5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all
newly constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME:
SIGNATURE: l -
DATE. IZ'
Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017
- - Manual S Compliance Report Job:
wrightsoft
Date: Jan 10,2018
Entire House By:
K & E Sheet Metal, LLC
22 Hudson Falls Road,Door#26,South Glens Falls,NY 12803 Phone:(518)746-0182 Email:ray@kesheetmetal.com Web:www.kesheetmetal.com
Project Information
For: Geof&Cheryl Hoffman-Addition Remodel,Gauthier Skilled Craftsman-Jerry Ryan
1269 Bay Road, Lake George, NY 12845
Cooling Equipment
Design Conditions
Outdoor design DB: 85.0'F Sensible gain: 11810 Btuh Entering coil DB: 76.7°F
Outdoor design WB: 70.8'F Latent gain: 2516 Btuh Entering coil WB: 63.3°F
Indoor design DB: 75.0°F Total gain: 14326 Btuh
Indoor RH: 50% Estimated airflow: 1047 cfm
�t
t
Manufacturer's Performance Data at Actual Design Conditions �'A
Equipment type: Split AC --
Manufacturer: Nordyne Model: FS3BA-018KA+C3BA-024-A -
Actual airflow: 1047 cfm
Sensible capacity: 7500 Btuh 64%of load
Latent capacity: 7500 Btuh 298%of load
Total capacity: 15000 Btuh 105%of load SHR: 50%
Heating Equipment
Design Conditions
Outdoor design DB: -10°F Heat loss: 28962 Btuh Entering coil DB: 68.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Oil furnace
Manufacturer: Nordyne Model: 04HD-091A-12-F
Actual airflow: 1047 cfm
Output capacity: 58100 Btuh 201%of load Temp. rise: 0 °F
p IEc� 1Eod�
JAN 16 2018
Meets are all requirements of ACCA Manual S. TOWN OF QUEENSBURY
BUILDING&CODES
sa
2018-Jan-11 14:17:28
wrightsoft" Right-Suitee Universal 2017 17.0.23 RSU24732 Page 1
Ca+ ...Craftsman-Jerry Ryan-Hoffman Residence.rup Calc=MJ8 Front Door faces: N
Load Short Form Job:
- - wrightsoft Date: Jan 10,2018
Entire House By:
K & E Sheet Metal, LLC
22 Hudson Falls Road,Door#26,South Glens Falls,NY 12803 Phone:(518)746-0182 Email:ray@kesheetmetal.com Web:www.kesheetmetal.com
Project Information
For: Geof&Cheryl Hoffman-Addition Remodel, Gauthier Skilled Craftsman-Jerry Ryan
1269 Bay Road, Lake George, NY 12845
Design Information
Htg Clg Infiltration
Outside db(°F) -10 85 Method _Simplified
Inside db('F) 70 75 Construction quali
Design TD(°F) 80 10 Fireplaces U V 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference(gr/Ib) 53 27 AN 1 ti 2018
Su wutENSBI iliny
HEATING EQUIPMENT
Make Nordyne Make Nordyne
Trade Tappan Trade Tappan
Model 04HD-091A-12-F Cond FS3BA-018KA
AHRI ref Coil C3BA-024-A
AHRI ref
Efficiency 80 AFUE Efficiency 9.7 EER, 10 SEER
Heating input 72625 Btuh Sensible cooling 7500 Btuh
Heating output 58100 Btuh Latent cooling 7500 Btuh
Temperature rise 51 °F Total cooling 15000 Btuh
Actual air flow 1047 cfm Actual air flow 1047 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.104 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.82
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
Bed 449 9060 4836 332 504
Bathroom 115 3109 462 114 48
Closet 108 1615 156 59 16
Loft 558 14796 4601 542 479
Entire House 1230 28580 10056 1047 1047
Other equip loads 382 1754
Equip. @ 0.90 RSM 10629
Latent cooling 2516
TOTALS I 1230 I 28962 I 13145 I 1047 I 1047
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
is' 2018-Jan-11 16:03:26
r. wrightsoftRight-Suite@ Universal 2017 17.0.23 RSU24732 Page t
/ i ...Craftsman-Jerry Ryan-Hoffman Residence.rup Calc=MJ8 Front Door faces: N
116
Specification Sheet Item#: - 61
D. 2017-08-24
SHR 150 --�FILE COPY �._
s NVIp
Heat Recovery Ventilator c��u
Product#: 99213
Fans
Two (2)factory-balanced fans with backward curved blades. Motors come
`° ... with permanently lubricated, sealed ball-bearings to guarantee long life
and maintenance-free operation.
Heat Recovery Core
Aluminum heat recovery core covered by a limited lifetime warranty. Core
dimensions are 9"x 9" 1229 x 229 mm)with a 15"(380 mm)depth.Our
heat exchangers are designed and manufactured to withstand extreme
temperature variations.
Defrost
A preset defrost sequence is activated at an outdoor air temperature of
23°F(-5°C)and lower. During the defrost sequence,the supply blower
Fantech's side port connection HRV for budget conscious house projects, shuts down&the exhaust blower switches into high speed to maximize
the SHR 150 unit brings a continuous supply of fresh air into a home the effectiveness of the defrost strategy.The unit then returns to normal
while exhausting an equal amount of contaminated air. During winter, operation, and continues cycle.
fresh incoming air is tempered by the heat that is transferred from the
outgoing air so you save on energy costs,while during summer, the Serviceability
incoming air is pre-cooled if the house is equipped with an air cooling Core, filters,fans and drain pan can be easily accessed through latched
system.The SHR 150 is equipped with automatic defrost mechanisms door. Core conveniently slides out on our new easy glide core guides. 17"
so you can use your HRV all year long. (432 mm) of clearance is recommended for removal of core.
Features Case
• Compact design 24 gauge galvanized steel. Baked powder coated paint.
• Fans with backward curved blade Insulation
• Electrostatic filters (washable) Cabinet is fully insulated with 1" (25 mm) high density expanded
• Aluminum heat recovery core polystyrene.
• Removable screw terminal for easy connection
• Lighweight 46 lbs (20Kg) Filters
• Multiple speed operation Two (2)washable electrostatic panel type air filters 8.5"(216mm)x 15"
Optional Controls (380mm)x 0.125"(3mm).
• ECO-TouchTM c#44929) — Programmable Touch Screen Wall Control Controls
• EDF7 i#448e31 — Electronic multi-function dehumidistat External three (3) position (Low/Stand By/Medium) rocker switch that will
• RTS2 (#40164) — 20 minute timer over-ride offer continuous ventilation. Fantech offers a variety of external controls.
• RTS5 1#44794) — 20/40/60 minute timer (see controls)
• MDEH1 440172) — Dehumidistat
Installation
Specifications Unit is typically hung by using installation kit supplied with unit. Mounting
• Duct size — 6" (152 mm) bolts provided on top four(4)corners of unit.An optional wall bracket is
• Voltage/Phase — 120/1 available.
• Power rated — 156 W
• Amp — 1.4 A Warranty
• Average airflow — 159 cfm (75 L/s) Limited lifetime on aluminum core, 7 year on motors, and 5 year on
®0.4"Ps 1100Pa) parts.
fantech '
a systemair company
Dimensions&Airflow
. M> fresh air
to inside
fresh air
A from outside
stale air
from inside
stale air
B A �B C9to outside
SHR 150 233/4 604 2118 55 171/4 438 161/4 414
Clearance of 17"(432 mm)in front of the unit is recommended for removal of core.All units feature three foot
plug-in power cord with 3-prong plug.
Ventilation Performance Airflow,(Usl
26 35 47 59 71 83 94 10
1.2 300
1.0 Supply 250
Net supply airflow 162(96) 159(751 128(60) 101 148) 88(42) 0.8 O. Exhaust 200
Gross supply airflow 186(88) 162(771 130(82) 103(48) 90(42) 1 2
0.6 150
Gross exhaust airflow 187(881 165 178) 140(66) 114(54) 66(411 E
a 0.4 100
rn
n 0.2 50
0.050 75 100 125 150 175 200 2250
Airflow(cfm)
Energy performance
Supply temperature Consumed power Sensible recovery Apparent sensible Latent recovery/moisture
efficiency effectiveness transfer
32 0 85 40 70 61 76 -0.02
32 0 101 48 94 63 71 -0.02
32 0 159 75 140 60 66 -0.01
-13 -25 85 40 71 58 75 -0.01
Requirements and standards
• Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
• Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators
• Technical data was obtained from published results of test relating to CSA 0439 Standards
Contacts Distributed by:
Submitted by: Date:
Quantity: Model: Project#•
Comments:
Location:
Architect:
Engineer: Contractor:
United States 10048 Industrial Blvd.•Lenexa,KS 66215•1.800.747.1762•www.fantech.net
Canada 50 Kanalflakt Way•Bouctouche,NB E4S 31M5•1.800.565.3548•www.fantech.net
Fantech,reserves the right to modify,at any time and without notice,any or all of its products'features,designs, fantech "
components and specifications to maintain their technological leadership position, ♦�•..�:
a systemair company
r
REScheck Software Version
■
6.4
Compliance Certificate
pECEOdc
Project Hoffman Addition
JAN 0 3 2018
Energy Code: 2015 IECC
Location: Glens Falls, New York TOWN OF QUEENSBURY
Construction Type: Single-family BUILDING&CODES
Project Type: Addition _, _ __ _ REVIEWED FOR
Climate Zone: 6 (7635 HDD)
Permit Date: ENERGY CODE COMPLIANCE
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
1269 Bay Road Geof Hoffman Gerald Ryan
Queensbury, NY 12804 1269 Bay Road Gauthier Skilled Craftsman, LLC
Queensbury, NY 12804 30 Delaware Avenue
Hudson Falls, NY 12839
Compliance: 6.4%Better Than Code Maximum UA: 156 Your UA: 146
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Perimeter
Ceiling 1: Flat Ceiling or Scissor Truss 621 38.0 0.0 0.030 19
Wall 1: Wood Frame, 16" o.c. 1,664 21.0 6.6 0.040 60
Window 1: Metal Frame:Double Pane with Low-E 123 0.300 37
Door 1: Glass 40 0.250 10
Floor 1: All-Wood joist/Truss:Over Unconditioned Space 621 30.0 0.0 0.033 20
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature OF NEW Date
L3 (6
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\Users\Jerry\Documents\REScheck\hoffman.rck Page 1 of 9
REScheck Software
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 97.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-inspection/Plan Review I Complies? Comments/Assumptions
& Req.ID Value v Value I
103.1, :Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
IY-
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302..1, :,Heating and cooling equipment is; Heating: Heating: ❑Complies ;Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA
'''Manual J or other methods ; Cooling: Cooling: ❑Not Observable
approved by the code official, Btu/hr Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\Users\erry\Documents\REScheck\hoffman.rck Page 2 of 9
Section
# Foundation Inspection Complies? Comments/Assumptions
&Req.ID
303.2.1 A protective covering is installed to ❑Complies Requirement will be met.
[FO11]2 protect exposed exterior insulation ❑Does Not
and extends a minimum of 6 in. below
grade. ❑Not Observable
❑Not Applicable
403.9 ;Snow-and ice-melting system controls ❑Complies Exception: Requirement is not applicable.
[FO12]2 installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\UsersVerry\Documents\REScheck\hoffman.rck Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Glazing U-factor(area-weighted U- U- ;❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or401
,
taken from the default table. ❑Not Observable
w ❑Not Applicable
402.4.1.1 :Air barrier and thermal barrier Ag 11 ❑Complies Requirement will be met.
[FR23]1 installed per manufacturer's ❑
Does Not
instructions. r
ivy' ❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met.
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate :52.0 cfm
.leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics �'❑Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_
R-6 where < 3 inches. Supply and ,❑Not Observable
return ducts in other portions of J ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as 3❑Complies Requirement will be met.
[FR15]3 'ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- �w ❑Complies Exception: Requirement is
[FR17]2 above 105 °F or chilled fluids ❑Does Not not applicable.
below 55 °F are insulated to >_R
3 ;❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies 'Requirement will be met.
[FR2411 piping. ❑Does Not
[]Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met.
[FR18]2 >_R-3. ❑Does Not
4 ❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies Requirement will be met.
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable ,
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\Users\Jerry\Documents\REScheck\hoffman.rck Page 4 of 9
1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\UsersVerry\Documents\REScheck\hoffman.rck Page 5 of 9
Section Plans,Verified Field Verified
# I Insulation Inspection Value Value Complies? Comments/Assumptions
&Re .ID
ry
303.1 ;All installed insulation is labeled ❑Complies Requirement will be met.
[IN13]1 or the installed R-values y. []Does Not
provided.
""[]Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- []Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 E] Steel ❑ Steel ❑Not Observable
[]Not Applicable
303.2, Floor insulation installed per ❑Complies •Requirement will be met.
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor '❑Not Observable _
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members. ti �
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies ;See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]1 :exterior, the exterior insulation 0-1 mass Mass []Not Observable
requirement applies (FR10). ❑ Steel ❑ Steel []Not Applicable
303.2 Wall insulation is installed per ❑Complies Requirement will be met.
[IN4]1 manufacturer's instructions.
[]Does Not
;
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\Users�erry\Documents\REScheck\hoffman.rck Page 6 of 9
Section Plans Verified Field Verified
4t Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, Ceiling insulation R-value. R- R- '❑Complies ;see the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not ;table for values.
402.2.2,
402.2.6 E] Steel E] Steel ❑Not Observable
[FI1]1 ❑Not Applicable
303.1.1.1, :Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable
402.2.3 iVented attics with air permeable ❑Complies Requirement will be met.
[FI22]2 !insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
;extends over insulation. ❑Not Observable I
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[F13]1 insulation >_R-value of the ;❑Does Not
adjacent assembly.
❑Not Observable
;❑Not Applicable
402.4.1.2 i Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ;❑Complies Requirement will be met.
[F117]1 ach in Climate Zones 1-2, and ;❑Does Not
<=3 ach in Climate Zones 3-8. ,❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies Exception: All ducts and air
[F14]1 cfm/100 ft2 across the system or ! ftft2 E❑Does Not handlers are located within
<=3 cfm/100 ft2 without air i conditioned space.
handler @ 25 Pa. For rough-in ❑Not Observable
tests, verification may need to ;❑Not Applicable
occur during Framing Inspection. i
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception: All ducts and air
[F127]1 determine air leakage with i ft2 ft2 ❑Does Not !handlers are located within
either: Rough-in test:Total conditioned space.
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch i❑Not Applicable
w.g. across the system including
the manufacturer's air handler
'enclosure if installed at time of
;test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 'Air handler leakage designated ❑Complies Requirement will be met.
[F[24]1 I by manufacturer at <=2%of ❑Does Not
;design air flow.
❑Not Observable
❑Not Applicable 1
403.1.1 Programmable thermostats ❑Complies
[FI9]2 ;installed for control of primary ❑Does Not 1
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
=code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies Requirement will be met.
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies Exception: Requirement is
[FI11]2 systems have automatic or ❑Does Not not applicable.
accessible manual controls.
❑Not Observable ..
❑Not Applicable
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\Users�erry\Documents\REScheck\hoffman.rck Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system r ❑Complies :Exception: Requirement is
01
[F125]2 fans not part of tested and listed ' ❑Does Not not applicable.
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
I KA-a-
❑Not Applicable
403.2 Hot water boilers supplying heat '❑Complies Exception: Requirement is
[F126]2 through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water (' ,[]Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 :Heated water circulation systems El Complies Exception: Requirement is
[F128]2 have a circulation pump.The ❑Does Not not applicable.
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos .. []Not Applicable
;syphon circulation systems are
not present. Controls for .
:circulating hot water system
pumps start the pump with signal:
;for hot water demand within the
occupancy. Controls '
automatically turn off the pump
when water is in circulation loop
- is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[F129]2 'comply with IEEE 515.1 or UL ❑Does Not not applicable.
515. Controls automatically .
;adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable
!desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies Exception: Requirement is
(F130]2 have recirculation pumps that ❑Does Not not applicable.
,pump water from a heated water
supply pipe back to the heated ❑Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
,demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
,of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies Exception: Requirement is
[F131]2 tested in accordance with CSA >° ❑Does Not not applicable.
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side
aterside pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75% of lamps in permanent ❑Complies :Requirement will be met.
[F16]1 fixtures or 75% of permanent ❑Does Not
fixtures have high efficacy lamps
Does not apply to low-voltage ❑Not Observable
lighting. ` � - ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies Exception: Requirement is
[F123]3 no continuous pilot light. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ( 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\UsersVerry\Documents\REScheck\hoffman.rck Page 8 of 9
Section i Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[F17]2 ❑Does Not
z❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies i Requirement will be met.
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
[-]Not Observable
[]Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Hoffman Addition Report date: 01/03/18
Data filename: C:\UsersUerry\Documents\REScheck\hoffman.rck Page 9 of 9
Efficiency2015 IECC Energy
Certificate
Above-Grade Wall 27.60
Below-Grade Wall 0.00
Floor 30.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Window 0.30
Door 0.25
Heating System:
Cooling System•
Water Heater:
Name• Date:
Comments
_ 4
t
s
i
r
DEC
18 201 ;
-
i
OWN pFCUEENSBURY
BUILDING&CODES
—�
XaJ
Fri
., �.
o
4
.... 70
Fri
0-01 .
-
278.-1-52 RC-000782-2017
Hoffman,
1269 Bay Road .
-
__-- Residential Addition 852 s.f.
�U
14A 6 91
j J
r
-
t
t i
)i
f
1
_ lr�� ARoPoS�t?
I
r
/75 '
_ s
I
NDvsc '