Loading...
RC-000738-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000738-2017 Date Issued: Tuesday, April 17, 2018 This is to certify that work requested to be done as shown by Permit Number RC-00073 8-2017 has been completed. Tax Map Number: 308.8-1-81 Location: 23 WOODEN LN Owner: Michaels Group Homes, LLC Applicant: Michaels Group Homes, LLC This structure may be occupied as a: Single Family Dwelling w/FP 1654 s.f. Garage 764 s.f. By Order of Town Board Lot 25 Laric Development TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the r: property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 fu Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-00073 8-2017 Tax Map No: 308.8-1-81 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 23 WOODEN LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tvne of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $280,000.00 Owner Address: 1 Marions Way Total Value $280,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marions Way Mechanicville,NY 12118 Plans&Specifications Single Family Dwelling w/FP 1654 s.f. Garage 764 s.f. Lot 25 Laric Development $1,345.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,December 4,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o ueensb J/tootf4,2017 SIGNED BY: or the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION � Office Use Only T,,,v � aLlsl Bate: )*,-, i PermitNo. P (,--a_v® 739-- av 7 Ta.-c MV s`D Dlik,.�- �� 1 Permit Fee Zone Historic'? _Yes No f Rec Fee Subdivision Name Bum-w 1Ab � s c-� Lot Project Location z3 Wc-o� L&A,, � 1T; ° TOWN BD.RESOLUTION 86-2013: $850 recreation fee for new din.[ u itsM*lJfgm20 pl x -family,multiple family, apartments,condominiums,townhouses,and/or manufactured&r Ic a homes,but not mobile s..This is in addition to the permit fee(s). Primary€ wner(s) � UPI � &CODES Address Phone/Email Applicant Address Phone/Email Contractor � S�•vrt c ��. �3t,� Address I'hane/Email Contact Person for B-uilding&Codes Compliance: TYPE OF CONSTRUCTION 1 I � ✓Check all that apply New I Addition Alteration ! 1'`hoc sf 2'dfloor sf Tot" Y Single Family ' X I I �b'�g l�toF Lfo-11 '% Two-Family Multi-Family (9 of units i Townhouse � I jBusiness Office Retail-Mercantile ! ! I I jFactory-Industrial j I f 1 Attached Garage (t, Q 3, 4Y-) Nt ?�4 I Other ` I 3 I Town of Queensbury Building&Codes Principal Structure Application reprised January 201-16 If com.miercial or industrial please indicate name of business Proposed use of building or addition Source of Heat(circle one) Oil Pro-Dane Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances & Chimneys Are there structures not shown on plot plan? t'lc> Are there easements on the property? fl Site Information: a. Dimensions or acreage of lot b. Is this a comer lot? Yes No c. Will the grade be changed as a result of construction Yes No d. Public water or Private well(circle one) Oublic Private e. Sewer or Private Septic System (circle one) Sewer QnLvat-e-�) Value of all work to be performed(labor or materials) $ 2-80) 0 oo — DECLARATION.- I- 11 acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 1 If work, is not complete by the I year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement description of the work proposed, that all work will be performed in accordance with the TNYS Building Codes, local building laws and ordinances,and in conformance with local zoning regulations 4. 1 acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate C of occupancy. 5. 1 also understand that I/we are required to provide an as-built sur-,,ey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: P RIIN T NTA-N-f E: 5C 10 DATE: 2- 91Z-17 SIGNATURE: DATE: 2, � l �� For office use oniv Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy TiMit Special Conditions Town of Queerisbury Building&Codes Principal Structure Application Revised January 2016 Office Use Only Fuel Bul inn Appliance C inine Application .7 Received T7-� DATE: I L 7 l T%x M ID Map Permit No. TAX MI AP III: Permit Fee ZONE: i i OWNER `A ��S ��..a PHONE//E-MAIL �; > 11 ADDRESS A.lz1 l �►-'�, M m�i At-kic'i I L-Ls my 1 Z1 va f INSTALLER PHONE/E-MAIL � 5�lb Ct too O f 1 BUILDER CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: T011% IDC"CAC> ( I PHONE/E-MAIL 'S1"a>-b6') 3144 BUILDING ADDRESS 23 Wvoi�`�1 Ll�.tV= ROOM OF INSTALL: C-40-'Da IZoCAA PLANNED INSTALL BATE: 'I ibtD FiJEL BURNING APPLIANCE INFOR�iA;ION SNOOD COAL PELLET JAS OIL L3TE: ROUGH-IN& !r STOVE FINAL INSPECTIONARE� � I FIREPLACE INSERT � ; I REALD. NOTE:FIREPLACE FACTORY BUILT* I ( � X � I 9 IYI-L�tUFACTIIIZER S FIREPLACE,MASONRY 1 I I T'+ISTAi.LA'I'Tt?N V1AiYTJAL FURNACE(GARAGE ONLY) E IVITST BE AVAILABLE AT j TIiVTE OF INSPECTION *If factory built provide manufacturer name: 'r4 -t--CL LO Fisted by: v Number: CHIMNEY INFORMATION Masonry** (check one) ; BLOCK BRICK STONE Flue TIE STEEL Size in inches I Material t DOUBLE WALL ,TRIPLE WALL INSULATED ** If non-nnasonry provide manufacturer name: ;Model #: DECLAR TION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or o,;vner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises t0 perform required inspections. I HAVE READ AND AGREE TO THE ABOVE:, PRIITdTNAIAE: ��a� �� 5 C Ia DATE: )t 12-)(1/7 SIGNATR✓IP..E: - DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Oniv { . Received DATE: 1 27 I ► 7 Tax Map ID Permit No. TAX MAP ID: Permit Fee ZONE: APPLICANT k%d1 T-*A:�'1.Q C,t'zckL 1-1Uv_k s, L-..0 PHONE/E-MAIL R)si; . ADDRESS 1 L4AW. iJtc'C.i•t;W -CV lwe- , Kr-e tzt1ce� INSTALLER I C14 b itR t"S 1 PHONE/E-ti1AIL -j A-1 . Ci 3-1) BUILDER !i OWNER � M 1 CGN p-153_S C_ ZCXA> K&"G Cs ,'-LC. f Sk c6c,C1 .10 2_;.)i ADDRESS 2 3 V,\OdCoesl LL A (_%1A STNt-%- bti70 5�� ! CONTACT PERSON FOR BUILDING&CODE COMPUANCE: = 1 PHONE/E-N3AiL ta •314 4- i RESIDENCE INFORMATION Year Built +of bedrooms X gallons per bedroom =total Daily flow 1980 or older I( s Garbage grinder installed !Yes No i 1981-I99I ! I f Spa or Hot Tub installed Yes No 1992-Present PARCEL INFORMATION t fI Topography Flat rolling Steep slope %Slope Soil Mature Sand Loam Clay Other Groundwater ( At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply ! Municipal Well(if well,water supply from any septic system absorption is ft.) j Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) PROPOSED SYSTEIM FOR NEW CONSTRUCTION � yTank size gallons(min.size 1,000 gallons,add 250 gallons to size for each garbage cylinder or spa or hot tab E System Absorption field with 42 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: Holding Tank System f Total required capacity? Tank size #of tanks, Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency,21)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file—no exceptions. Deciaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to crake a material fact or circumstance known by or on behalf of an applicant,shall be void.i have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: BATE: SIGNATUU: DATE: Town of Queensoury Building&Codes Principal Structure Application Revised January 2016 Y Town of Queensbury Thomas R.Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Hone: 518-745-0938 DRIVEWAY PERMIT Date: 2 7 Applicant Name: `Lo'a , Telephone No.: Address to be Inspected 2,2, Return Address: 1 MIIWt-I S Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location The Superintendent of FEghways of the Town of Queensbury has reviewed tl s application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( } Slight Swale ( ) Deep Swale ( } .Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" { ; 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( } Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell,Deputy highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 INSPECTION WORKSHEET (FMGAS-002673-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000738-2017Case Module:Permit Inspection Date:04/17/2018Inspection Status:Passed Inspector:Gary StillmanInspection Type:Gas Fireplace/Stove Job Address:23 WOODEN LNParcel Number:308.8-1-81 Queensbury, NY 12804 Contact TypeCompany NameName Contractor\[Michaels Group Homes, LLC\], Applicant\[Michaels Group Homes, LLC\], Primary Owner\[Michaels Group Homes, LLC\], Granted Permission\[Michaels Group Homes, LLC\], Checklist ItemPassedComments Fire Marshal NotesYESInspection cancelled by contractor, unit not installed yet 3/5/18 - Heat n Glo Model SL-750 Building Inspector NotesYES4/17/2018 HEAT&GLO MODEL- SL-7 SERIAL # LC4732315 NATURAL GAS Floor ProtectionYES Clearances to Combustibles (all sides)YES Firestop(s) - Vertical ChaseYES Vent Clearance to CombustiblesYES Vent Chimney TerminationYES Gas Shut-off ValveYES Combustion AirYES Witness OperationYES4/17/18 ok CO DetectionYES4/17/18 ok Stillman, Gary (Inspector) Apr 17, 2018Page (2) IF" I 23 Wooden Ln HVAC Df ! T n el NOyu2 9 2017 TOWN OF QUEENSBURY BUILDING&CODES R9--sTE EwnAL., RHV A- CHVAC LoAms, 308.8-1-81 RC-000738-2017 Michaels Group Homes 23 Wooden Lane, Lot 25 SFD w/FP 1654 s-f., Garage 764 s.f. Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Wednesday, November 22, 2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. �Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.A,ppolo Heating Inc. 23 Wooden Ln Schenectady,NY 12306 Page 2 Project Report - General Project Information Project Title: 23 Wooden Ln Designed By: The Michaels Group Project Date: Wednesday, November 22, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 . Design Data Reference City: Schenectady, New York Building Orientation: Front door faces Southeast Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 927 CFM Per Square ft.: 0.284 Square ft. of Room Area: 3,261 Square ft. Per Ton: 1,740 Volume (ft'): 29,179 Building Loads — Total Heating Required Including Ventilation Air: 50,171 Btuh 50.171 MBH Total Sensible Gain: 20,119 Btuh 89 % Total Latent Gain: 2,365 Btuh 11 % Total Cooling Required Including Ventilation Air: 22,484 Btuh 1.87 Tons (Based On Sensible+ Latent) Notes ' Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i C:\Users\nicks\Documents\Elite Software\Rhvac 9 Projects\23 Wooden Ln.rh9 Wednesday, November 22, 2017,4:24 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appaia Heating Inc. 23 Wooden Ln Schenectady,NY 12306 Pae 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains In ut Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in,wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.280 AC/hr 0.150 AC/hr 136 CFM 73 CFM Infiltration Actual: 0.280 AC/hr 0.150 AC/hr Above Grade Volume: X 29,179 Cu.ft. X 29.179 Cu.ft. 8,170 Cu.ft./hr 4,377 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 136 CFM 73 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr(136 CFM), Construction: Average Summer Infiltration Specified: 0.150 AC/hr(73 CFM), Construction:Average r i 1 - i i i I C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\23 Wooden Ln,rh9 Wednesday, November 22, 2017, 4:24 PM [Rhv a-c-Residential&Light Commercial HVAC Loads t Elite Software Development,Inc. A,ppei3 Heating Inc. 23 Wooden Ln Schenectady,NY 12306 Page 4 Load Preview Report - -- i Ming' I Min' Sys' Sys` Sys Net, ft.. Sen Lat, Net Sen CFMi I Duel Scope I Tori fro Area Gai Gairi Gal nn' Loss; Ht Ctg Hfg Clg' Act Siz I_ j CFMj CFM. CFM. CFM? Building 1.87 1,740 3,261 20,119 2,365 22,484 50,171 661 927 661 927 927 System 1 1.87 1,740 3,261 20,11 2,365 22,484 50,171 661 927 661 927 927 12x1 Zone 1 3,261 20,119 2,365 22,484 50,171 661 927 661 927 927 12x1 1-Basement 1,656 2,323 626 2,949 16,781 221 107 221 107 107 1-6 2-Kitchen 88 952 34 986 1,626 21 44 21 44 44 1-4 3-Dining 247 1,942 135 2,077 5242 69 89 69 89 89 1-6 4-Great Room 249 2,435 54 2,489 3,772 50 112 50 112 112 2-4 5-Home Office 179 2,338 62 2,400 3,294 43 108 43 108 108 1-6 6-Foyer 61 974 66 1,040 1,964 26 45 26 45 45 1--4 7-Bath 1 78 874 30 904 1,382 18 40 18 40 40 1-4 8-Bedroom 2 216 2,607 465 3,072 5,338 70 120 70 120 120 2-4 9-Mud Room 70 806 30 836 1,498 20 37 20 37 37 1-4 I 10-Master Bedroom 274 3,092 741 3,833 5,726 75 142 75 142 142 2-5 11-WIC 67 528 0 528 635 8 24 8 24 24 1-4 12-Master Bath 76 1,249 122 1,371 2,913 38 58 38 58 58 1 i c C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\23 Wooden Ln.rh9 Wednesday, November 22, 2017,4:24 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. lIJ�Rri Heating Inc. 23 Wooden Ln Schenectady, NY 12306 Pa e 5 Duct Size Preview Room or ` I Minimum Maximum Rough Desigrj SPI Duct; Duct Htg Cig Act. Duct Duct Name Source rrrr�� Velocii}j Velocity Factor L(100 Loss) Velocity Length Flow Flow i Flow Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 545.3 221 107 107 1-6 2-Kitchen Built-In 450 750 0.01 0.1 502.9 21 44 44 1-4 3-Dining Built-in 450 750 0.01 0.1 455.7 69 89 89 1-6 4-Great Room Built-In 450 750 0.01 0.1 642.8 50 112 112 2-4 5-Home Office Built-In 450 750 0.01 0.1 548.7 43 108 108 1--6 6-Foyer Built-In 450 750 0.01 0.1 514.3 26 45 45 1-4 7-Bath 1 Built-In 450 750 0.01 0.1 461.3 18 40 40 1 8-Bedroom 2 Built-In 450 750 0.01 0.1 688.3 70 120 120 2-4 9-Mud Room Built-In 450 750 0.01 0.1 425.4 20 37 37 1-4 10-Master Bedroom Built-In 450 750 0.01 0.1 522.4 75 142 142 2-5 11-WIC Built-In 450 750 0.01 0.1 278.8 8 24 24 1 12-Master Bath Built-In 450 750 0.01 0.1 659.7 38 58 58 1-4 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 794.7 661 927 927 12x1 Summary System 1 Heating Flow: 661 Cooling Flow: 927 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\23 Wooden Ln.rh9 Wednesday, November 22, 2017, 4:24 PM ----------- KRhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. �Heating Inc. 23 Wooden Ln nectad , NY 12306 Page 6 Total Building Summary Loads Component Area Sen tat Sen Total Description Quan Loss Gain Gain Gain ' Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 135.2 2,891 0 3,246 3,246 Pella Slider: Door-Slider 81.6 1,690 0 564 564 Front Door TMG: Door-TMG Entry U-Value 0.19 34 446 0 149 149 Fire Rated: Door-Fire Rated 20.4 394 0 131 131 12E-Obm: Wall-Frame, R-19 insulation in 2 x 6 stud 1346.4 9,569 0 1,165 1,165 cavity, no board insulation, brick finish, metal studs 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1534.2 6,880 0 1,226 1,226 cavity, no board insulation, siding finish,wood studs 166-50: Roof/Ceiling-Under Attic with Insulation on Attic 88 121 0 83 83 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1516.5 2,722 0 1,852 1,852 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1656.5 2,857 0 0 0 , or more feet below grade, no insulation below floor, i any floor cover, shortest side of floor slab is 24'wide 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1380.8 10,558 0 1,835 1,835 on exposed walls, sealed or vented space, passive, no floor insulation,carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 223.7 1,848 0 322 322 on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl Subtotals for structure: 39,976 0 10,573 10,573 People: 3 900 1,200 2,100 Equipment: 0 0 0 Lighting: 1990 6,786 6,786 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 136, Summer CFM: 73 10,195 1,465 951 2,416 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: -_ 0 0 609 609 Total Building Load Totals: 50,171 2,365 20,119 22,484 Check Figures - Total Building Supply CFM: 927 CFM Per Square ft.: 0.284 Square ft. of Room Area: 3,261 Square ft. Per Ton: 1,740 Volume(ft3): 29,179 Building Loads Total Heating Required Including Ventilation Air: 50,171 Btuh 50.171 MBH Total Sensible Gain: 20,119 Btuh 89 % Total Latent Gain: 2,365 Btuh 11 % Total Cooling Required Including Ventilation Air: 22,484 Btuh 1.87 Tons (Based On Sensible+ Latent) Notes - Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\23 Wooden Ln.rh9 Wednesday, November 22, 2017, 4:24 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Opo Heating Inc. 23 Wooden Ln Schenectady,NY 12306 > Page 20 [System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Cig Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 1,656 16,781 221 1-6 545 2,323 626 107 107 2 Kitchen 88 1,626 21 1-4 503 952 34 44 44 3 Dining 247 5,242 69 1-6 456 1,942 135 89 89 4 Great Room 249 3,772 50 2-4 643 2,435 54 112 112 5 Home Office 179 3,294 43 1-6 549 2,338 62 108 108 6 Foyer 61 1,964 26 1-4 514 974 66 45 45 7 Bath 1 78 1,382 18 1-4 461 874 30 40 40 8 Bedroom 2 216 5,338 70 2-4 688 2,607 465 120 120 9 Mud Room 70 1,498 20 1-4 425 806 30 37 37 10 Master Bedroom 274 5,726 75 2-5 522 3,092 741 142 142 11 WIC 67 635 8 1-4 279 528 0 24 24 12 Master Bath 76 2,913 38 1-4 660 1,249 122 58 58 System 1 total - 3,261 50,171 661 20,119 2,365 927 927 System 1 Main Trunk Size: 12x14 in. Velocity: 795 ft./min Loss per 100 ft.: 0.101 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.87 89%/11% 20,119 2,365 22,484 Actual: 2.33 75%/25% 21,000 7,000 28,000 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B* 13ACXN030-230** Indoor Model: C35-30B*+TDR Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 28,000 Btuh Sensible Capacity: n/a 21,000 Btuh Latent Capacity: n/a 7,000 Btuh AHRI Reference No.: n/a 8736592 i i C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\23 Wooden Ln.rh9 Wednesday, November 22, 2017,4:24 PM REScheck Software Version 4,6.2 0 N �p Compli ' ' ate C6 H ECE0WE m � m Q � N a NOV 2 9 217 of N�Uix v E o � Project The Barberry i 1 0 � �0 R0p �'0 � = J ,� Energy Code: 2015 IECC TOWN OF QUEENSBURY C/) � ' � C C � * � Location: Warren Cou G&CODES * � O J CX) Construction Type: Single-family Project Type: New Construction r = t 0. 00 0 LL Conditioned Floor Area: 1,654 ft2 ��sFO Og6�( ��,� C Glazing Area 15% ROFE O Climate Zone: 6 (8499 HDD) Permit Date: 20 November, 2017M LL Permit Number: �2 C-4 Construction Site: Owner/Agent: Designer/Contractor: 23 Wooden Lane Michaels Group Homes, LLC Queensbury, NY 1 Marions Way Mechanicville, NY Compliance: Passes using UA trade-off Compliance: 5.6%Better Than Code Maximum UA: 284 Your UA: 268 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter Ceiling: Raised or Energy Truss 1,654 0.0 38.0 0.025 41 Walls: Wood Frame, 24" o .c. 1,755 21.0 0.0 0.056 83 Entry#1: Solid 21 0.170 4 1x Bed #2 (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 1x Bath (AA): Vinyl Frame:Double Pane with Low-E 5 0.300 2 1x Home Office (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9 Dining #7: Glass 40 0.300 12 1x Kitchen (BV): Vinyl Frame:Double Pane with Low-E 44 0.300 13 Master Bed #7: Glass 40 0.300 12 1x Master Bed (BL): Vinyl Frame:Double Pane with Low-E 8 0.300 2 1x Master Bath (AM): Vinyl Frame:Double Pane with Low-E 7 0.300 2 Mud #20: Solid 19 0.170 3 Basement Walls: Solid Concrete or Masonry 1,482 0.0 19.0 0.039 56 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' 2x Std Bsmt Win: Vinyl/Fiberglass Frame:Double Pane with Low-E 4 0.310 1 Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 1 of 10 Gross Area Cavity Cont. Assembly or U-Factor UA 1x 5030 Sliding Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.310 5 Garage Stair#7: Solid 19 0.170 3 Compliance Statement: The proposed building design described here is consistent with th building plans, specifications, and other calculations submitted with the permit application.The proposed building h s en des' ed to meet the 2015 IECC requirements in REScheck Versiio (�on 4.6.2 and to comply with the mandatory requirements Ii din th check Inspection Checklist. K el tp/ . J— /14-4 Name- I It1q, Signatur Date i Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. I Section i i Plans Verified Field Verified # Pre-inspection/Plan Review { Value Value Complies? Comments/Assumptions & Req.ID 1 103.1, Construction drawings and ❑Complies I 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR311 lighting and mechanical systems.41 ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 3 of 10 Section Plans Verified Field Verified ' # Foundation Inspection Complies? t Comments/Assumptions i Value Value & Req.iD� 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO411 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies (FO5]1 insulation installed per ❑Does Not to manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft i ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. _]Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not U' [-]Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 4 of 10 Section Plans Verified 1 Field Verified # Framing/Rough-in Inspection) Complies? 1 Comments/Assumptions & Req.ID -_ Value _ Value I 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable 4, ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ;t taken from the default table. []Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not 4 instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ] ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 l=` ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 152.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >=R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where<3 inches. Supply and [:]Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 4F or chilled fluids ❑Does Not below 55 QF are insulated to >_R- ❑ 3 Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not � ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are „- ' „ ❑Complies [FR19]2 installed on all outdoor air bF ❑Does Not intakes and exhausts. r ❑Not Observable -❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact ( Tier 2) 3 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 5 of10 Addddmns| Camnnnents/Aasunmpdsns: 1 High Impact(Tier 1) 2 Med huml rn pact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Barberry Report date: II/20/I7 Datafi|ename: F:\Share\Design\Res'[heck\BurntRidge\Z3Wooden Lane.rzh Page 0ofIO Section I Plans Verified Field Verified # insulation inspection Complies? Comments/Assumptions & Req.ID Value Value i 303.1 All installed insulation is labeled ❑Complies [IN13)z or the installed R-values El Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3)1 exterior, the exterior insulation ❑ Mass Mass Ell Observable 14 requirement applies (FR10). Steel Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN411 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 !Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? i Comments/Assumptions & RegJD 402.1.1, Ceiling insulation R-value. �R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood []Does Not table for values. 402.2.2, 402.2.6 E] Steel ❑ Steel ❑Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per []Complies303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 300 ft2. '❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies JF122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated y r❑Com plies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [Flg]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 8 of 10 Section Plans Verified Field Verified # Final Inspection Provisions value Value Complies? Comments/Assumptions &i& Req. 1403.6.1 All mechanical ventilation system ❑Complies 1[F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable OW90"go'LlNot Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating a ❑Does Not systems have outdoor setback �,,. rx • <<F� ,. control to lower boiler water ❑Not Observable 1 temperature based on outdoor []Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply,"' upplyy, [-]Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and _no demand for hot water exists. 403.5.1.2 Electric heat trace systems '� r ;: �'�4;ter ❑Complies [F12 9]2 comply with IEEE 515.1 or UL 3. ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the 1r` ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump waterfrom a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a ' demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature "r of the water entering the cold r water piping to 1044F. 403.5 4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat []Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one f, # or two showers. Potable water- 1, side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage []Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. []Doesoes Not ❑Not Observable 01MMEINot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 9 of 10 Section Plans Verified Field Verified # Final inspection Provisions I Com lles7 Comments/Assumptions tions & Req.iD i Value Value p p 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating []Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 !Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Barberry Report date: 11/20/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\23 Wooden Lane.rck Page 10 of10 2015 IECC Energy Efficiency Certificate Insulation . Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): D.. . Window 0.30 Door 0.30 Cooling'Heating& Heating System: Cooling System: Water Heater:_ Name: Date: Comments Map Reference: Map Of A Proposed Subdivision Made For C lda uric Development, LLC .. Dated:April 10, 2003 r^ (Si��l(11' 1S S d0 Last Revised: January 4, 2014 �� ���Iv�j By, flan D�asen & Steves �H�. 02� � a= Filed. March 3, 2014, Plat C-340 JSI�]Hi���i��'4�W AII'� � H S�3d d o a Z. 308.8-1-81 RC-000738-2017 32 j O �- Michaels Group Homes S 330 '° I r Wooden Lane, Lot 25 � � �`' 23 _�— SFD w/FP 1654 s.f., Garage 764 s.f. LST 25 \\ 44296,9 Sq, Feet v 1 ,02 Acres S Co A Ib Hill Sao r \ � s1�yles•g� \,,.... NMp 3 01 M Map Reference: Map of a Proposed Subdivision Made for Laric Development,LLC Dated:April 10,2003 Last Revised:January 4,2014 By:Van Dusen&Steves Filed:March 3,2014,Plat C-349 ,-Vo LOT 24 Notes: 1. Surveyed parcel is subject to easements,covenants,and agreements of record. 2. Surveyed parcel is subject to conditions of the subdivision approval Cable,Boz S 33032,03 R = 325.00' 2g0,47� = 64.61 ' N } S58029'35"W 19 Ch = 64.50' (Original Burnt Hills Subdivision) W�na°,UWell Elec.Meter �. 1 'e Wood Frame House- LOT louseLOT 25 F en 44296.9 Sq. Feet W 1.02 Acres B Ln O 18 ♦� cm r �� w (Original Burnt U) �. Hills Subdivision) 5� co 0 a co Cu a o ee Re o. T�a�=I I �abHe � 402.11 ' N 260 13' 15" W 17 >.. (Original Burnt Hills Subdivision) W LOT 26 LOT 36 C� Z 4, O _O z 4 ,/J ■ / ) . ,"z '' Wig"^p ''S e. I Y'C. 90 R or sv CQ C 3x1 t F Dat le; March 28, 2018 S 'UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY Scale 1"=30' MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A Map of a Survey made for VIOLATION OF SECTION 7209,SUB-DIVISION 2,OF THE NEW YORK STATE EDUCATION LAW." 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS Chester E • M o s k a 1 8c SEAL SHALL BE CONSIDEREE TO VALID TRUE COPIES.' 1 'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT 1 THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE �/T EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTEDBY THE NEW Kathleen E • Wilson STATE ASSOCIATION OF PROFE Land S ti r V e J o r s LAND SURVEYOR•SAID CERTIFICATIONS SHALL RUN IONAL ONL7 To THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND - ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL - SHEET 1 OF 1 169 Haviland Road Queensbury New York 12804 AGENCY AND LENDING INSTITUTION LISTED HEREON,AND Town of Queensbury, Warren County, New York TO THE ASSIGNEES OF THE LENDING INSTITUTION." Moskal/Wilson (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 99-241-Larlc_Lot 25