Loading...
CC-000744-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-820 1 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-000744-2017 Date Issued: Tuesday, March 27, 2018 This is to certify that work requested to be done as shown by Permit Number CC-000744-2017 has been completed. Tax Map Number: 288.16-1-1 Location: 1424 State Rte 9 Owner: Vera Bradley, Lake George Northway LLC Applicant: This structure may be occupied as a: Commercial Interior Alterations 2922 s.f. Tenant: Vera Bradley, Space 12 By Order of Town Board (formerly Nautica) TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, 00 Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. � TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: CC-000744-2017 Tax Map No: 288.16-1-1 Permission is hereby granted to: Vera Bradley For property located at: 1424 State Rte 9 In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance lype of Construction Owner Name: Vera Bradley Retail-Mercantile-Alteration $90,000.00 Owner Address: 12420 Stonebridge RD Total Value $90,000.00 Roanoke,IN 46783 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications Commercial Interior Alterations 2922 s.f. Tenant:Vera Bradley,Space 12 (formerly Nautica) $ 0.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,January 23, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before th xpiration a .) Dated at the Town Queen �I ue nuary 23,2018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement ,... Office Use Only ADDITION/ALTERATION PERMIT Permit#: APPLICATION Permit Fee: $ �� o Town of CZeensbury 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.gueenssbury.net .�, 3 Project Location: k �� 1 ��`�tL— �1, I Tax Map ID #: 2 b`i7 = 1 \ -1 Subdivision Name: n ties d CONTACT INFORMATION: `J • Applicant: Name(s): Joyin ri - Mailing Address, C/S/Z: -3]2-5 Q dLr Avg $ LA 9 Cell Phone: '3.o ) 'R90-7 Land Line: 3 I a 1 IL4 1 Email: 01, . <, • Primary Owner(s): Name(s): P r:1- 0 rc.' t"' Mailing Address, C/S/Z: 247-0 r I ASe- 'oz. Cell Phone: (160 ) '2�101 LaH Line: Email: • Contractor(s): '"11) Business Name: Fnn C E 0 VV E nn Contact Name(s): IN 7 1111 Mailing Address, C/S/Z: Cell Phone: �_) Land Line: WV QUEENstsmy Email: BUILD Architects)/Engineer(s): Business Name: Ar Contact Name(s): Mailing Address, C/S/Z 1' Q Cell Phone: 310 ) �$0�` Land Line: (3i6�) Email: '71) Contact Person for Building & Code Compliance: 1306 + v Cell Phone: (3iv Land Line: Email: i 6 '' ` ..a - C dOvin Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 PROJECT INFORMATION: TYPE: •✓ Commercial Residential WORK CLASS: Single-Family _Two-Family _Multi-Family(#of units ) Townhouse Business Office Retail Industrial/Warehouse _Garage (#of cars ) Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: `Z 2nd floor: 2nd floor: 3rd floor: 3rd floor: 41h floor: 41h floor: Total square feet: Total square feet: -Z92 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 01000 2. If Commercial project, what is the proposed use: L2��'�� > 3. Source of Heat (circle one): Oil Propane Solar Other Fireplaces need a separate Fuel Burning Appliances&Chimney Application 4. Are there any structures not shown on the plot plan? YES V Explain: 5. Are there any easements on the property? YES 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel?t.. b. b. Is this a corner lot? YES c. Will the grade be changed as a result the construction? YES d. What is the water source? PC PRIVATE WELL e. Is the parcel on _t9R or a PRIVATE SEPTIC system? Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 INSPECTION WORKSHEET (BINS-002154-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-000744-2017Case Module:Permit Inspection Date:03/27/2018Inspection Status:Passed Inspector:John O'BrienInspection Type:Commercial Final Inspection Job Address:1424 State Rte 9Parcel Number:288.16-1-1 Lake George, NY 12845 Contact TypeCompany NameName EngineerNelson, Randall Primary OwnerVera Bradley, Property Owner\[Lake George Northway LLC\], ContractorCollery, Paul ArchitectEpoch Design Group, TenantVera Bradley, Granted PermissionVera Bradley, Checklist ItemPassedComments Chimney / B Vent / Direct Vent LocationYES Plumbing Vent Through Roof/Roof completeYES Doors 36 inch wLever Hand Panic Hardware, if reqYES Exits At Grade Or Platform 36 (w) x 44 (l)YES Gas Shut-off Exposed & Regulator (18) Above GradeYES Floor Bathroom Watertight Other Floors OkayYES Relief Valve ,Heat Trap/Water Temp 110 deg or lessYES Gas Furnace Shut OffYES H/C Bathroom Grab Bars /Sinks/Toilets/MirrorsYES Handicapped Bath/Parking Lot SignageYES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucetYES Universal Symbol of Access displayed - on all H/C signsYES Handicapped Service Counters 34 inchYES Final Electrical / Flex Gas Piping BondedYES Bldg Num or Tenant Address on Bld or DriveYES Bldg Access All Sides 20ft Drivable SurfaceYES Special InspectionsYES-Provide Air Balancing Report for HVAC System Mar 27, 2018Page (3) INSPECTION WORKSHEET (BINS-002154-2018) Checklist ItemPassedComments OK to Issue C/OYES3/22/18 Final Inspection Not Approved Remaining Items: -Provide Air Balancing Report for HVAC System -Complete all Fire marshal?s Items. 3/26/18 Final Inspection Not Approved -Received Air Balancing Report Remaining item: -Complete all Fire Marshal's Items. 3/27/18 Final Inspection Approved-Ok to issue CO! O'Brien, John (Inspector) Mar 27, 2018Page (4) DE!CLAP,ATION: 1. 1 acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: SIGNATURE: DATE: 11-211-7 Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised February 2017 INSPECTION WORKSHEET (BINS-002091-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-000744-2017Case Module:Permit Inspection Date:03/26/2018Inspection Status:Failed Inspector:John O'BrienInspection Type:Commercial Final Inspection Job Address:1424 State Rte 9Parcel Number:288.16-1-1 Lake George, NY 12845 Contact TypeCompany NameName Primary Owner\[Vera Bradley\], EngineerNelson, RandallNelson, Randall Architect\[Epoch Design Group\], Property Owner\[Lake George Northway LLC\], Tenant\[Vera Bradley\], Granted Permission\[Vera Bradley\], Checklist ItemPassedComments Chimney / B Vent / Direct Vent LocationYES Plumbing Vent Through Roof/Roof completeYES Doors 36 inch wLever Hand Panic Hardware, if reqYES Exits At Grade Or Platform 36 (w) x 44 (l)YES Gas Shut-off Exposed & Regulator (18) Above GradeYES Floor Bathroom Watertight Other Floors OkayYES Relief Valve ,Heat Trap/Water Temp 110 deg or lessYES Gas Furnace Shut OffYES H/C Bathroom Grab Bars /Sinks/Toilets/MirrorsYES Handicapped Bath/Parking Lot SignageYES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucetYES Universal Symbol of Access displayed - on all H/C signsYES Handicapped Service Counters 34 inchYES Final Electrical / Flex Gas Piping BondedYES Bldg Num or Tenant Address on Bld or DriveYES Bldg Access All Sides 20ft Drivable SurfaceYES Special InspectionsYES-Provide Air Balancing Report for HVAC System OK to Issue C/ONO3/22/18 Final Inspection Not Approved Remaining Items: -Provide Air Balancing Report for HVAC System -Complete all Fire marshal?s Items. 3/26/18 Final Inspection Not Approved -Received Air Balancing Report Remaining item: -Complete all Fire Marshal's Items. O'Brien, John (Inspector) Mar 26, 2018Page (11) (Z:LFIRE MARSHAL'S OFFICE Tozun of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Vera Bradley FILE COW11 1424 State Route 9, #12 CC-000744-2017 12/4/2017 I have reviewed the submitted drawings for the above project, and offer the following comments: 1) Fire extinguisher locations to be discussed. 2) Locks / latches shall comply with 2015 IFC. Existing hardware in space is compliant. 3) CO detection is required. 4) Provide a key for the plaza Knox Box. 5) Provide a NFPA 13 letter from sprinkler contractor. 6) Exit / Emergency light plan appears adequate, Fire Marshal's office to witness a function test prior to CO. 7) Provide a horn strobe in the space per section 606.4.1 of the 2015 IMC to signal duct smoke activation. Deputy Fire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 Fax: 518-745-4437 lremarshal@queensbunLnet • TeTaMqueensburu net COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information (� (� j"` Energy Code: 2015 IECC D E C E E Project Title: Vera Bradley Location: Lake George, New 6 H 01 2017 Climate Zone: 6a Project Type: Alteration TOWN OF QUEENSBURY BUILDING&CODES Construction Site: Owner/Agent: Designer/Contractor: Lake George, NY KS Mechanical Systems List Quantity System Type& Description 1 RTU-1 (Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=224 kBtu/h Proposed Efficiency=82.00%Et, Required Efficiency=80.00%Et Cooling: 1 each-Single Package DX Unit,Capacity=90 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=12.00 EER,Required Efficiency: 11.00 EER +12.6 IEER Fan System: RTU--Compliance(Motor nameplate HP method) :Passes Fans: FAN 1 Supply,Constant Volume,3000 CFM, 1.5 motor nameplate hp,0.0 fan efficiency grade 1 EWH-1: Electric Storage Water Heater,Capacity: 10 gallons No minimum efficiency requirement applies Mechanical Compliance Statement Compliance Statement. The proposed mechanical alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMchVersi 0.7.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. 17`�-a4t.-/"'echN.i�o�� H,� eck l� 4l(7 Name-Title Si re Date 288.16-1-1 CC-000744-2017 Vera Bradley 1424 State Route 9 Commercial Alterations 2922 s.f. Project Title: Vera Bradley Report date: 11/21/17 Data filename: G:\Epoch Design Group\Vera Bradley\1720362 VB-Lake George, NY(The Outlets at Lake Page 3 of 12 George)\Energy\VB-Lake George, NY, 2015 IECC.cck COMcheck Software Versill 288.16-1-1 CC-000744-2017 Vera Bradley Interior Lighting Co 1424 State Route 9 Commercial Alterations 2922 s.f. Project Information fZ Vv rC 2 l5 V E Energy Code: 2015 IE 1I Project Title: Vera Br, / Project Type: Alterati DEC Q 1 2017 Construction Site: Own /A enOtWjY Ld N&CODS 9 Bu esigner/Contractor: Lake George, NY KS Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail:Sales Area 1983 1.59 3153 Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:T/SP 525(a) 1.40 735(b) Allowance:Other retail highlighting/Fix.ID:T/SP 428(a) 0.60 257(b) Allowance:Other retail highlighting/Fix.ID:T/SP 555(a) 0.60 333(b) 2-Common Space Types:Restrooms 79 0.98 77 3-Common Space Types:Storage 957 0.63 603 Supplemental Allowed Watts(null)= 294 Total Allowed Watts= 5452 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified. (b)Allowance is(B x C)or the actual wattage of the fixtures given in Proposed Power section,whichever is less. (c) Supplemental watts must be associated with retail merchandise highlighting fixtures. Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail:Sales Area(1983 sq.ft.) Track lighting-General:T/SP:Track mounted light fixtures: Wattage based on current limiting 0 0 1080 1080 device capacity Track lighting-Floor Display:T/SP:Track mounted light fixtures: Wattage based on current 0 0 960 960 limiting device capacity Track lighting Wall Display-W:T/SP:Track mounted light fixtures: Wattage based on current 0 0 840 840 limiting device capacity Track lighting Wall Display-E:T/SP:Track mounted light fixtures: Wattage based on current 0 0 840 840 limiting device capacity Track lighting-Show window:T/SP:Track mounted light fixtures: Wattage based on current 0 0 360 360 limiting device capacity Track lighting-Nightlight:T/SP:Track mounted light fixtures: Wattage based on current 0 0 120 120 limiting device capacity Incandescent 1:B:Pendant Light fixture:Incandescent 60W: 1 3 60 180 Linear Fluorescent 3:K3:3'Strip:35"T5 21 W:Electronic: 1 34 23 Exempt Exemption:Lighting Integral to Equipment Common Space Types:Restrooms(79 sq.ft..) Incandescent 2:J:Restroom Vanity:Incandescent 25W: 4 1 240 240 Common Space Types: torage(957 sq.ft.) Linear Fluorescent 5:C/GE:4'Strip:48"T8 32W(Super T8):Electronic: 2 26 32 832 Project Title: Vera Bradley Report date: 11/21/17 Data filename: G:\Epoch Design Group\Vera Bradley\1720362 VB- Lake George, NY(The Outlets at Lake Page 1 of 12 George)\Energy\VB-Lake George, NY, 2015 IECC.cck A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Linear Fluorescent 3 copy 1:K3:3'Strip:35"T5 21 W:Electronic: 1 34 23 Exempt Exemption:Furniture-mounted Supplemental Task Lighting Total Proposed Watts= 5452 Interior Lighting Compliance Statement Compliance Statement. The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.7.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. t`c el rl -" JU2 Name-Title Si ; r DatEf Project Title: Vera Bradley Report date: 11/21/17 Data filename: G:\Epoch Design Group\Vera Bradley\1720362 VB-Lake George, NY(The Outlets at Lake Page 2 of 12 George)\Energy\VB-Lake George, NY, 2015 IECC.cck