Loading...
RC-000799-2017 TOWN OF QUEENSBURY Ba 742� I y Road,Queensbury,NY 12804-5904 (518)761-8201 - _ Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000799-2017 Date Issued: Friday, May 11, 2018 This is to certify that work requested to be done as shown by Permit Number RC-000799-2017 has been completed. Tax Map Number: 308.12-1-45 Location: 24 WOODEN LN Owner: Michaels Group Homes, LLC Applicant: Michaels Group Homes, LLC This structure may be occupied as a: SFD w/gas FP 1939 s.f. Garage 759 s.f. By Order of Town Board Lot 20, Laric Development TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the 41 property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Lnforcem nt Planning Board or Zoning Board of Appeals. 4FLTOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-000799-2017 Tax Map No: 308.12-1-45 Permission is hereby granted to: Michaels Group Homes, LLC For property located at: 24 WOODEN LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Tv)e of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $290,000.00 Owner Address: 1 Marion Way Total Value $290,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marion Way Mechanicville,NY 12118 Plans&Specifications SFD w/gas FP 1939 s.f. Garage 759 s.f. Lot 20,Laric Development $ 1,401.65 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday,February 9,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before pthnexpiration dale.) Dated at the Town f Quee s ury; Fri a ary 9, 2018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement U11JUf UDC U111V Permit#: PRINCIPLE STRUCTURE PERMIT APPLICATION Permit Fee:$ Town of Queensbtwy r *Rec Fee: $ 742 Bay Road,Queensbury,NY 12804 P: 518-761-8256 www.queensburv.net Invoice#: Project Location: Z-4 �olz>eE" Tax Map ID #: 50b - �3- - I -�CD S u b d i v i s 1 o,n Name: P-L*-)r-V-W In�C-i C-') *TOWN BID. RESOLUTION 86-20111 $850 recreation fee for new dwelling units: single family,duplexes/two-family, multiple family, apartments, condominiums,townhouses, and/or manufactured & modular homes, but not mobile homes. This Is In addition to the permit fee(s). CONTACT INFORMATION: * Applicant: Name(s): "ICA-kP-A565 CArzb-X-1 LAC.. MailingAddress, C/S/Z: I WAY, HO:t4ANICVI�. Cell Phone: Land Line: Email: 0 Primary Owner(s): Name(s): Mailing Address. C/S/'-I-'- &q� nw W Z 9 %fl [E Cell Phone: Land Line: ---�7 1 151 Email: nn L PCB Z3 291? • Contractor(s): 3U TOWN OF QUEENSB Zi Ry Business Name: BUILDING&CODES Contact Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: Email: * Arch itect(s)/Engineer(s): Business Name: Contact Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) S-79. 240'z Land Line: E m a i 1: V--Vu7r---TZT c--'--.>I P—1-4yC-A-V'- Contact Person for Building & Code Compliance: Cell Phone: ( >\,o ) Land Line: Email: 'T�CA-1-Lic> e- CCA-A Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 PROJECT INFORMATION: TYPE: Commercial X. id- -I WORK CLASS: X Single-Family Two-Family _,Multi-Family(#of ) _Townhouse Business Office Retail Hotel/Motel IndustriaUWarehouse Garage(#of cars Other(describe ) STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 11T floor: 1sT floor: 4 2nd floor: '13 4 2nd floor: 3rd floor: - Total square feet: 4th floor: Total square feet: k ,q 39 E ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 7`l0 - 2. Proposed use of the building: s�t.1c{u� �p1►�ltt.Y �ii�+ t 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): 40 Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances & Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES NO Explain: 6. Are there any easements on the property? YES 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? 7 , 7— b. - 7b. Is this a corner lot? YES NO c. Will the grade be changed as a resu t of the construction? YES NO d. What is the water source? PUBLI PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? L- own of Queensbury Building&Code Enforcement Principle Structure Apptation Revised February 20Ti DECLARATION: 1. 1 acknowledge that no construction shall commence prior to issuance of a valid b u i Iding permit and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: ��i��y SIGNATURE: DATE: 17-1 )z f 1-, Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 Town ® Queensbury Thomas R. Van Ness Highway Superintendent Highway Home (518) 745-0929 Department Daviel Duell 742 Bay Road—Queensbury, NY 12801 Deputy Highway Superintendent Phone: (518) 761-8211 Home (518) 743-0938 Fax: (518) 745-4466 DRIVEWAY PERMIT DATE: IZI IZ)1—r APPLICANT NAME: M►C.k-MELS CtJ2Xt0,� LL�C- TELEPHONE NO.: 5106 .e6r1Cti•X0311 ADDRESS TO BE INSPECTED: 'Z4 Llth"t- RETURN ADDRESS: 1`�I�N��+11u� N.Y tZ11� Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt: (or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent FUEL BURNING APPLIANCE & office use Only CHIMNEY APPLICATION Permit#: Permit Fee:$ Invoice:#: 742 Bay Road,Queensbury, NY 12804 P: 518-761-8256 www.gueensburV.net Project Location: 2<1 He aL��_ Tax Map ID 4: Room of Install: _7LcPlanned Install Date: **ONE APPLICATION PER APPLIANCE" CONTACT INFORMATION: 9 Applicant: Name(s): M1C_,VfbAEL-- LA-C- Mailing Address, C/S/Z: IMAS ct-k"— M=-L*kA*ML 1 174% Cell Phone: ) Land Line: Email:- J -e- STm-sf-cc�o A * Primary Owner(s): Name(s): Ar-> 4E7 Mailing Address, C/S/Z: Cell Phone: J—) Land Line: J—) Email: 0 Installer/builder: Business Name: FZz--- Contact Name(s): ci=er-s. 14�%X'-% Mailing Address, C/S/Z: 1-7a-2 cAEN4-rw-?'�•- Cell Phone: -( 5V?> Land Line: J—) Email: Contact Person for Building & Code Compliance: IZ' Kee Cell Phone: ( ) t6rzi'l .2-444- Land Line: Email: 1 L.-CCD-'r-'CaO � W C4AP.G:?_SC_JVz0_JF-.co*A Fuel Burning Appliance &Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION- TYPE OF DEVICE: Stove _Fireplace Insert V-Fireplace _ Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) X Fireplace, factory built** **Manufacturer's name: Hcy- tA- 4LC, Model #: '5L--'7E4Z:) SOURCE OF HEAT: _Wood _Coal _ Pellet )4 Gas CHIMNEY INFORMATION: _ Masonry: block brick stone _ Flue: tie _steel _size, in inches _Material*: double-wall _triple-wall_insulated (*Manufacturer's name: Model #: ) ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer"s installation manual must be available at the time of inspection. 3. Masonry fireplaces & chimneys require plans to be submitted. 4. Twenty-four (24) hour notification is required for inspections. Declaration:Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: SIGNATURE: DATE: 12 LY ll 7 Fuel Burning Appliance &Chimney Application Revised March 2017 : . SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only _. 742 Bay Road,Queensbury,NY 12804 Rran af(Zccnsh°ry #: P:518-761-8256 www.gueensburynet Permit Tax Map ID#: Permit Fee:$ ; Invoice#: Project Location: _24 �^`���� Septic Variance? Yes No Primary Owner(s) M1C*fib' 4— CtSZ0_-)P ,Lt_C_ Mailing Address I i AAA=C->I'LS trlb�l, },�f -1 tC�1►wa', tato 1Z11� Phone & Email 5ke> 9 r . C_M" Installer/Builder -r�, s. �tny �,cNr� Mailing Address 54. NX__92=g}.\ '�ST, �4 Phone & Email -5�lb X 4-7,-y-377 Engineer NhZX_-- t✓�.1�� , P.C. Mailing Address => � 2, v, }�`�' 12 4- Phone Phone & Email .7 4-3 . 4-4-p� Contact Person for Building&Code Compliance: Phone: RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes 40, 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes N Installed? (circle one) 1992-Present ! ti 3 3 PARCEL INFORMATION: Topography Flat Rolling Steep Slope %Slope Soil Nature �_Sand Loam Clay Other Groundwater At what depth? Bedrock/Impervious material At what depth? N1 Domestic Water Supply _Municipal _Well (if well, water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size I LCz gallons(min.size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length 7 e ft.; Each Trench '' ft. Seepage Pit with#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size ;#of tanks NOTES: 1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency; 2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. 1 / PRINT NAME: i" �"' ~ �� ` S C/b DATE: L Y l SIGNATURE: DATE: LSA Town of Queensbury Building&Code Enforcement Revised February 2017 6 !MAKE�-UP FURNACE FRESH AIR INTAKE RETURN AIR YJ/WEATHER HOOD / PLENUM 'SEE EQUIPMENT & DUCT SIZINGUND METAL CALCULATIONS SUBMITTED WITH PERMIT APPLICATION FOR ADD'L INFORMATIONLE -AIR"FR -UP KIT W/ AMPER (SEALG5) MECHANICAL VENTILATION SYSTEM NOTES: MEGHANIGAL VENTILATION SHALL BE PROVIDED IN COMPLIANCE WITH IRC R303 B IRC,M1501.3.1. VENTILATION SYSTEM SHALL GON5IST OF EXHAUST FANS(LOCATED®MASTER AND MAIN BATHS) USED IN CONJUNCTION WITH A FRESH-AIR MAKE-UP DAMPER CONNECTED TO THE RETURN-AIR . PLENUM OF FURNACE(SEE ADJACENT DIAGRAM) VENTILATION REQUIRED: = 60cfm CONTINUOUS(PER TABLE M1507.5.50)OR 120cfm AT 50%RUN TIME PER TABLE M1501.3.3G(2) VENTILATION PROVIDED: (2)500m FANS(MAIN d MASTER BATH)OPERATING®50%RUN TIME (2-HOUR INTERVALS) = IbOcfm> 1206fm.PROGRAMMABLE TIMERS SHALL BE PROVIDED AT EACH EXHAUST FAN LOCATION. MAKE-UP AIR DAMPER SHALL OPERATE VIA A PROGRAMMABLE TIMER WHIGH COINCIDES WITH BATH FAN TIMERS(2-HOUR INTERVALS)TO ELIMINATE NEGATIVE PRESSURE WITHIN HOME MECHANICAL VENTILATION - 24 WOODEN LANE REScheck Software Version 4.6.2 FILE COPY Compliance Certificate 0 ��._... LO Q F N Project The Kimball \\H D R�� da N J CU Energy Code: 2015 IECC E N Location: Warren County, New York O +-' Construction Type: Single-family _ _J Project Type: New Construction' N CO N Conditioned Floor Area: 1,939 ft2 \� p �� = C Glazing Area 14% �'rC ylU�'�� O J Q Climate Zone: 6 (8499 HDD) Permit Date: 11 December, 2017 NO Permit Number: 0 C;) N to O Construction Site: Owner/Agent: Designer/Contractor: 00 L) . 24 Wooden Lane Michaels Group Homes, LLCp U_ Queensbury, NY 1 Marions Way M N U) Mechanicville, NY REVIEWED FOR Compliance:Passes using UA trade-off Compliance: 2.0%Better Than Code Maximum UA: 303 Your UA: 297 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Assembly or Cavity Cont. U-Factor UA Foundation Wall: Solid Concrete or Masonry 1,247 0.0 19.0 0.038 47 Wall height: 8.6' Depth below grade: 7.6' Insulation depth: 8.6' 1x 5030 Sliding Windows: Vinyl Frame:Double Pane with Low-E 15 0.300 5 2x Std. Basement Window: Vinyl Frame:Double Pane with Low-E 4 0.300 1 1st Floor Walls: Wood Frame, 24" o .c. 1,305 21.0 0.0 0.056 59 Foyer#1: Solid � � � 0.170 4 2x Home Office (0): Vinyl Frame:Double Pane with Low-E D0.300 11 1x Stair(AC): Vinyl Frame:Double Pane with Low-E 0.300 1 2x Great Room (AP): Vinyl Frame:Double Pane with Low-E DEC 2 9 2017 1 0.300 3 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 0.300 9 1x Great Room (R): Vinyl Frame:Double Pane with Low-E 'TOWN��QUEENS 2 0.300 8 St!lLD1NG&Ct)D #7 Breakfast: Glass 0.300 12 2x Dining (C): Vinyl Frame:Double Pane with Low-E 21 0.300 6 1x Dining (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 1x Mud (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 Mud #20: Solid 19 0.170 3 Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 1 of10 Gross Area Cavity Cont. Perimeter I 2nd Floor Walls: Wood Frame, 24" o .c. 1,016 21.0 0.0 0.056 51 2x Bed #3 (AT):Vinyl Frame:Double Pane with Low-E 32 0.300 10 lx Master Bed (G): Vinyl Frame:Double Pane with Low-E 32 0.300 10 lx Master Bath (Q): Vinyl Frame:Double Pane with Low-E 12 0.300 4 lx Master Bath (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 lx Main Bath (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 lx Bed #2 (AT): Vinyl Frame:Double Pane with Low-E 16 0.300 5 lx Laundry(AS): Vinyl Frame:Double Pane with Low-E 10 0.300 3 Ceiling: Raised or Energy Truss 1,111 38.0 0.0 0.025 28 Floor Above Garage: All-Wood Joist/Truss:Over Unconditioned Space 115 30.0 0.0 0.033 4 Laundry Floor Above Porch: All-Wood Joist/Truss:Over Outside Air 14 30.0 0.0 0.033 0 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements i ed in the REScheck Inspection Checklist. Name-Title Signa re Date Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 2 of 10 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section 1 Plans Verified Field Verified i # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.lD 103.1, Construction drawings and ❑Complies i 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies =103.2, documentation demonstrate ❑Does Not 1403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable n= Systems serving multiple ❑Not Applicable j dwelling units must demonstrate E compliance with the IECC Commercial Provisions, 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 1403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable j approved by the code official. Btu/hr Btu/hr ❑Not Applicable 3 i Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 3 of 10 Section plans Verified Field Verified f # ( Foundation Inspection Value Value Complies? Comments/Assumptions I& Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values. insulation is used, verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 1303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable ----------------- ------ — ---------- ----------- ---- 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F011]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. [-]Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not `❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 4 of10 r Section i Plans Verified Field Verified 3 # Framing/Rough-In inspection Value Value Complies? Comments/Assumptions & Req.ID, 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable 4 ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not «: instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built _ ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not 41 AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. _ 402.4.5 IC-rated recessed lighting fixtures �'❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where <3 inches. Supply and []Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not 91 ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55°F are insulated to >R []Not Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- —❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 5 of 10 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact-(Tier-2) 3 Low Impactt(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 6 of 10 Section I PFans Verified Field Verified # Insulation Inspection Value Value FCmplies? Comments/Assumptions %& Req.I D ---- -- ------- _ ---- ------ 303.1 All installed insulation is labeled ❑Complies i[IN13]z or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 1402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 1402.2.6 wall insulation on the wall [IN3]1 exterior,the exterior insulation [J Mass ❑ Mass ❑Not Observable requirement applies (FR10). E] Steel E] Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies 1[IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 7 of10 Section i Plans Verified ! Field Verified # Final Inspection Provisions 1 Value Value Complies? Comments/Assumptions & Req.ID' _ L- 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.6 ❑ Steel E] Steel [:]Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 Blown insulation marked every ❑ 300 ft2. Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI2211 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. [:]Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI311 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test@ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI1711 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI411 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable _occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F12711 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies (FI2411 by manufacturer at<=2%of ❑Does Not design air flow. [-]Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F 19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 8 of10 Section Plans Verified Field Verified Req.ID Final Inspection Provisions Value Value Complies? Comments/Assumptions 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable____________ 403.2 Hot water boilers supplying heat ❑Complies i[F126]2 through one-or two-pipe heating ❑Does Not I systems have outdoor setback ! ❑Not Observable control to lower boiler water temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the []Not Observable heat tracing to maintain the []Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold []Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not 855.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 9 of 10 ':, Section � Plans Verified Field Verified i # i Final Inspeetion Provisions � � Complies? I Comments/Assumptions & Re iD I Value � Value 11401.3 Compliance certificate posted. ❑Complies 1[F17]2 ❑Does Not E ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies ([F118]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/12/17 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\24 Wooden Lane.rck Page 10 of10 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling Equipment Heating System: Cooling System: Water Heater: Name: Date: Comments REVIEWED FOR ENERGY CODE COMPLIANCE F1�E COPY 24 wooden Lane HVAC Load CalCUlations for The Michaels Group 308.12-1-45 RC-000799-2017 Michaels Groups Home LLC 24 Wooden Lane, Lot 20 SFD wlgas fp 1939 s.f., Gar. 759 s.f. i , 3 Of1tware, RESIDEI�I MAL, RHVAC HVAC LOADS i _ I j i DEC 29 2017 TOWNOF QU ENSBURY Prepared By: BUILDING$ CODES Nick Abiuriza Appolo Heating 868 Burdeck St Schenectady Ny 92306 Monday, December 18, 2017 i Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D Rhvac R®Sldentiat&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 24 Wooden Lane Schenectady,NY 12306 Page 2 Pro Yect Report 1-General Project Information f Project Title: 24 Wooden Lane it Designed By: The Michaels Group Project Date: Tuesday, July 18, 2017 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 Design Data Reference City: Schenectady, New York Building Orientation: Front door faces Northwest Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains j Dry Bulb Wet Bulb Rei.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 Check Figures Total Building Supply CFM: 1,009 CFM Per Square ft.: 0.334 Square ft. of Room Area: 3,026 Square ft. Per Ton: 1,469 I Volume(ft'): 25,215 Building Loads -- v Total Heating Required Including Ventilation Air: 54,085 Btuh 54.085 MBH Total Sensible Gain: 21,905 Btuh 89 % Total Latent Gain: 2,804 Btuh 11 % Total Cooling Required Including Ventilation Air: 24,709 Btuh 2.06 Tons (Based On Sensible+ Latent) Notes —] Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i C:1Userslnicka\DocumentsUite SoftwarelRhvac 9 Projects124 Wooden Lane.rh9 Monday, December 18, 2017, 11:26 AM S Rhvac-Residential&Light Commercial HVAC Loads--- --._ Elite Software Development,Inc. Appolo Heating inc. 24 Wooden Lane Schenectady,NY 12306 Page 3 1 — Miscellaneous Report -- ISystem 9 Outdoor Outdoor Outdoor Indoor Indoor — Grains f+Input Data — Dry Bulb Wet Bulb Rel Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 80% — n/a 70 n/a j Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs _ . - -. .. Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./900 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 155 CFM 80 CFM Infiltration Actual: 0.370 AC/hr 0.190 AC/hr Above Grade Volume: X 25.215 Cu.ft. X 25.215 Cu,ft. 9,330 Cu.ft./hr 4,791 Cu.f,/hr X 0.0167 X 0.0167 Total Building Infiltration: 155 CFM 80 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration& Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp Difference) Infiltration&Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier.- 74,87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(155 CFM), Construction:Average Summer Infiltration Specified: 0.190 AC/hr(80 CFM), Construction_Average C:1UserslnickalDocumentslElite SoftwarelRhvac 9 Projects124 Wooden Lane.rh9 Monday, December 18, 2017, 11:26 AM Rhvac-Residential Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 24 Wooden Lane Schenectady,NY 12306 Page 4 11 Load Preview Report Neth ft. Sen La� Nets Sen Mini Mint Sys' Sys Sys Duc Scope To f o Are Gain Gai Gail Loss Htgi FMJ FMHtg! FN Acts Size I I CFM CFM CFM CFM1 CFM Building 2.06 1,469 3,026 21,905 2,804 24,709 54,085 712 1P09 712 1,009 1,009 System 1 2.06 1,469 3,026 21,905 2,804 24,709 54,085 712 1,009 712 1,009 1,009 12x1 Zone 1 3,025 21.905 2,804 24,709 54,085 712 1.009 712 1,009 1,009 120 1-Basement 1,024 1,903 420 2,323 11,13E 147 88 147 88 88 1- 2-Dining 143 1,776 151 1,929 5,224 69 82 69 82 82 1- 3-Great Room 337 2,682 181 2,863 6,868 90 124 90 124 124 2- f 4-Kitchen 186 1,105 72 1,177 2,627 35 51 35 51 51 1-4 5-Powder Room 30 416 13 429 464 6 19 6 19 19 1 6-Mud Roam 58 831 65 896 1,791 24 38 24 38 36 1-4 7-Foyer 76 907 96 1,003 2,328 31 42 31 42 42 1-4 8-Home Otfice 186 1,599 110 1,709 3,904 51 74 51 74 74 1- i 9-Master Bedroom 306 3,040 734 3,774 5,697 75 140 75 140 140 2- 10-Bedroom 3 168 2,256 399 2,655 3,806 50 104 50 104 104 1 11-Laundry 73 900 53 953 1,816 24 41 24 41 41 1-A 12-Bedroom2 166 1,999 399 2,398 3,506 46 92 46 92 92 1 13-Loft 81 551 0 551 764 10 25 10 25 25 1-4 14-Bath 1 67 770 26 796 1,184 16 35 16 35 35 1-4 ' 15-Master Bath 125 1,170 85 1,255 2,970 39 54 39 54 54 1-4 i R I i I i C:IUserslnicka\Documents\EIite Software\Rhvac 9 Projects124 Wooden Lane.rh9 Monday, December 18, 2017, 11:26 AM jRhvac-aesidential 8 Light Commercial HVAC Loads Elite Software Development,lnc. ppolo Heating Inc. 24 Wooden Lane Schenectady,NY 12306 Pa e 5 Duct Size Preview Room or Source Mirimu Maximurri Rough Desigr{ SP Duct,' Duct Htg Clg Act. Duct Duct Name VelociE Vetocil� Facto L(100 Lossl Velocity Length Flow Flow i Flow Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 643.2 147 88 88 1- 2-pining Built-In 450 750 0.01 0.1 600.7 69 82 82 1-5 3-Great Room Built-In 450 750 0.01 0.1 453.1 90 124 124 2-5 4-Kitchen Built-In 450 750 0,01 0.1 583.6 35 51' 51 1--4 5-POvderRoom Built-in 450 750 0.01 0.1 219.9 6 19 19 1- 6-Mud Room Bull(-In 450 750 0.01 0.1 438.7 24 38 38 1 i 7-Foyer Built-in 450 750 0.01 0.1 478.7 31 42 42 1 8-HomeOffice Built-In 450 750 0.01 0.1 540.2 51 74 74 1- 1 9-Master8edroom Built-In 450 750 0.01 0.1 513.6 75 140: 140 2-5 10-Bedroom 3 Built-in 450 750 0.01 0.1 529.4 50 104: 104 1-6 11-Laundry Built4n 450 750 0.01 0.1 475.4 24 41. 41 1-4 12-Bedroom 2 Built-In 450 750 0.01 0.1 469.2 46 92 92 1 1a-Loft BUIINn 450 750 0.01 0.1 291 10 25 25 1-4 14-Bath 1 Built-In 450 750 0.01 0,1 406.4 16 35 35 1-4 15-Master Bath Built-En 450 750 0.01 0.1 617.7 39 54 54 1_4 Other Ducts in System 1 Supply Main Trunk Built-in 650 900 0.003 0.1 807.5 712 1,009 1,009 12x1 Summary System 1 Heating Flow: 712 Cooling Flow: 1009 i E CAUserslnicka\Documents\Elite Software\Rhvac 9 Projects124 Wooden Lane.rh9 Monday, December 18, 2017, 1126 AM krsidential&Light Commercial HVAC Loads ,` Elite Software Development,Inc. Appolo Heating Inc. 24 Wooden Lane Schenectady, NY 12306 Pane 6 Notal Building Summary Loads Component Area Sen Lat Sen Total Description _ Quan Loss Gain Gain Gain Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 288.1 6,164 0 3,863 3,863 Pella Slider: Door-Slider 40.8 845 0 282 282 Fire Rated: Door-Fire Rated 21 246 0 82 82 Front Door TMG: Door-TMG Entry 21 246 0 82 82 12E-Obm: Wall-Frame, R-19 insulation in 2 x 6 stud 889.2 6,319 0 768 768 cavity, no board insulation, brick finish, metal studs 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2132.9 9,564 0 1,703 1,703 cavity, no board insulation, siding finish, wood studs 166-38: Roof/Ceiling-Under Attic with Insulation on Attic 986.1 1,770 0 1,205 1,205 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 21A-24: Floor-Basement, Concrete slab, any thickness,2 1024 1,766 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24`wide 119A-Ocp: Floor-Over enclosed crawl space, No insulation 1649.1 12,609 0 2,194 2,194 on exposed wails, sealed or vented space, passive, f no floor insulation, carpet or hardwood j 19A-Otp: Floor-Over enclosed crawl space, No insulation 352.6 2,914 0 507 507 j on exposed waifs, sealed or vented space, passive, j no floor insulation, tile or vinyl -_ Subtotals for structure: 42,443 0 10,686 10,686 People: 4 1,200 1,600 2,800 Equipment: 0 0 0 Lighting: 2480 8,457 8,457 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 155, Summer CFM: 80 11,642 1,604 1,039 2,643 Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 123 123 Total Building Load Totals: 54,085 2,804 21,905 24,709 Check Figures _ _ __ � Total Building Supply CFM: 1,009 CFM Per Square ft.: 0.334 Square ft. of Room Area: 3,026 Square ft, Per Ton: 1,469 Volume(ft'): 25,215 Building Loads Total Heating Required Including Ventilation Air: 54,085 Btuh 54.085 MBH Total Sensible Gain: 21,905 Btuh 89 % Total Latent Gain: 2,804 Btuh 11 % Total Cooling Required Including Ventilation Air: 24,709 Btuh 2.06 Tons(Based On Sensible + Latent) Notes ------------ - - - -� Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent toads according to the manufacturer's performance data at your design conditions. i i i i C:lUserstnicka\DocumentslEfite Software\Rhvac 9 Projects124 Wooden Lane,rh9 Monday, December 18,2017, 11:26 AM FFR6-v-ac'-kesidentia!&Light Commercial HVAC Loads vElite Software Development,Inc. Appolo Heating Inc. 24 Wooden Lane Schenectady NY 12306 Pa a 23 Sstem 9 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat CIg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 1,024 11,136 147 1-5 643 1,903 420 88 88 2 Dining 143 5,224 69 1-5 601 1,778 151 82 82 3 Great Room 337 6,868 90 2-5 453 2,682 181 124 124 4 Kitchen 186 2,627 35 1-4 584 1,105 72 51 51 5 Powder Room 30 464 6 1-4 220 416 13 19 19 6 Mud Room 58 1,791 24 1-4 439 831 65 38 38 7 Foyer 76 2,328 31 1-4 479 907 96 42 42 8 Home Office 186 3,904 51 1-5 540 1,599 110 74 74 9 Master Bedroom 306 5,697 75 2-5 514 3,040 734 140 140 10 Bedroom 3 168 3,806 50 1-6 529 2,256 399 104 104 11 Laundry 73 1,816 24 14 475 900 53 41 41 12 Bedroom 2 166 3,506 46 1-6 469 1,999 399 92 92 13 Loft 81 764 10 1-4 291 551 0 25 25 14 Bath 1 67 1,184 16 1-4 406 770 26 35 35 15 Master Bath 125 2,970 39 1-4 618 1,170 85 54 54 -System 1 total _ 3,026 54,085 712 21,905 2,804 1,009 1,009 System 1 Main Trunk Size: 1205 in. + Velocity: 808 ft./min Loss per 100 ft.: 0.100 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons _ _ S Emit Btuh Btuh Btuh Net Required: 2.06 89%/ 11% 21,905 2,804 24,709 Actual: 2.40 75%126% 21,600 7,200 28,800 [Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B` 13ACXN030-230-** Indoor Model: C35-24B+TDR+TXV Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 28,800 Btuh Sensible Capacity: n/a 21,600 Btuh Latent Capacity: n/a 7,200 Btuh AHRI Reference No.: n/a 8269470 i i I i C:IUserslnickalDocurnents\Elite Software\Rhvac 9 Projects124 Wooden Lane.rh9 Monday, December 18,2017, 1126 AM Yfl � t1 2005 EPACT Energy Efficient Home Tax Credit ( 13-001 ) Property Organization HERS Unknown Grajny Consulting, LLC Confirmed 24 Wooden Lane 518-221-3240 2018/05/10 Queensbury, NY 12804 Stan Grajny, PE Rating No:0311186 Rater ID:5609922 Weather:Watertown, NY Builder Registry ID: 617316826 24_WoodenLn Michaels Group Homes 0041-0749-C1_Michaels_Group_Ho mes_24_Wooden_Lane_ESv31_QA • Normalized, Modified End-Use Loads (MMBtu/yr) Envelope Loads (MMBtu/yr) 2006 IECC 2006 IECC 50%Target As Designed 90%Target As Designed Heating 37.5 _ ___ 35.9 Heating _ _ _ _ _.67.5 58.5 Cooling 3.2 3.1 Cooling 5.7 3.7, Total 40.7 39.0 Total 73.2 62.2 Building Features Ceiling Flat R-49.0 Exposed Floor R-30.0 Sealed Attic NA Slab R-0.0 Vaulted Ceiling NA Duct Uninsulated Above Grade Walls R-21.0 Window U-Value: 0.300, SHGC: 0.290 Foundation Walls R-19.0 Cooling Air conditioner, Electric, 13.0 SEER. Heating Fuel-fired air distribution, Natural gas, 95.0 AFUE. _ This home MEETS the requirements for the residential energy efficiency tax credits under Section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005 extended to December 31, 2016. As demonstrated above, this dwelling unit has a projected level of annual heating and cooling energy consumption that is at least 50%below the annual level of heating cooling energy consumption of a 2006 IECC reference dwelling in the same climate zone, and the building envelope components improvements alone account for at least 10%of those savings. The projected heating and cooling energy savings above have been calculated in the manner prescribed in Appendix A of the RESNET Publication No. 13-001. Field inspections of the dwelling unit performed by the undersigned eligible certifier during and after the completion of construction have confirmed that all features of the home affecting such heating and cooling energy consumption comply with the design specifications provided to the undersigned certifier. Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete. Name Stan Grajny, PE Date 11 May 2018 Company Grajny Consulting, LLC Address 80 Andriana Lane, Albany, NY 12204 Signature REM/Rate- Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. ©1985-2017 Noresco, Boulder, Colorado. • t t REM/Rate - Residential Energy Analysis and,Rating Software v15.4.2 New York Compliance Certificate Gross Area Cavity Cont, Glazing or Door Assembly or Perimeter R-Value R-Value U-Factor UA Joist 2: Cond->ambient 168 21.0 0.0 0 Window 1: U=0.30, S=0.29* 246 0.300 74 Door 1: Front-Custom-R-3.23* 21 0.310 0 Door 2: R7 steel instil* 19 0.143 0 Basement Walls Wall 1: R-13 Draped, Full` 1320 0.0 13.0 71 Wall 2: R-13 Draped, Full* 192 0.0 13.0 10 Window 2: U.0.30, S=0.29* 24 0.300 7 Mechanical Equipment Heating: Fuel-fired air distribution, 64.0 kBtuh, 95.0 AFUE. Water Heating: Conventional, Gas, 0.70 EF. Cooling:Air conditioner,28.4 kBtuh, 13.0 SEER. Required signatures vary depending upon state and or local codes, requirements and regulations. Check with your local building department to determine which signatures are required for your application. Builder or Authorized Employee certify that the home listed above shall be built to meet or exceed all requirements of the 2015 IECC as amended by the 2016 New York State Energy Conservation Construction Code and all current energy codes specific to the local jurisdiction in which the home is built. Name-Title Signature Date Rater I, Stan Grajny, PE of GRAJNY Consulting, LLC, certify that the home listed above, as modeled meets or exceeds all requirements of the 2015 IECC as amended by the 2016 New York State Energy Conservation Construction Code and all current energy codes specific to the local jurisdiction in which the home is built. I further attest that i am a certified Home Energy Rater and affiliated with FIL a HERS Provider accredited by RESNET and adhering to the requirements of the Residential Energy Services Network RESNET Standards. c\r),17,-- „ Name-Title S g t re D • • akv (11 Q ssaae ,(,•, ti ` ri;SSiC ,�' REM/Rate-Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. ©1985-2017 Noresco, Boulder, Colorado. Page 2 of 2 Home Energy Rating Certificate Property HERS Unknown Rating Type: Confirmed Certified Energy Rater: Stan Grajny, PE 24 Wooden Lane Rating Date: 2018/05/10 Rating Number: 0311186 Queensbury, NY 12804 Registry ID: 617316826 Estimated Annual Energy Cost, Use MMBtu Cost Percent HERS Index: 53 Heating - 62.2 $428 24% General Information Cooling 1.4 $54 3% Conditioned Area 2944 sq. ft. House Type Single-family detached Hot Water 14.4 $91 5% Conditioned Volume 24557 cubic ft. Foundation Conditioned basement Lights/Appliances 23.3 $748 42% Bedrooms 3 Photovoltaics -0.0 $-0 -0% Service Charges $448 25% Mechanical Systems Features Total 101.4 $1769 100% Heating: Fuel-fired air distribution, Natural gas, 95.0 AFUE. Water Heating: Conventional, Natural gas, 0.70 EF, 50.0 Gal. Criteria ' Cooling: Air conditioner, Electric, 13.0 SEER. This home meets or exceeds the minimum criteria for the following: Duct Leakage to Outside 9.00 CFM25. EPA ENERGY STAR Version 2.5 Home Ventilation System Exhaust Only: 72 cfm, 30.0 watts. EPA ENERGY STAR Version 3 Home Programmable Thermostat Heat=Yes; Cool=Yes EPA ENERGY STAR Version 3.1 Home ASHRAE Standard 90.2 - 1992 Building Shell Features 2015 International Energy Conservation Code Ceiling Flat R-49.0 Slab R-0.0 Edge, R-0.0 Under ECCC New York State 2016 Sealed Attic NA Exposed Floor R-30.0 Vaulted Ceiling NA Window Type U-Value: 0.300, SHGC: 0.290 Above Grade Walls R-21.0 Infiltration Rate Htg: 1129 Clg: 1129 CFM50 Foundation Walls R-19.0 Method Blower door test Stan Grajny, PE Grajny Consulting LLC Lights and Appliance Features 80 Andriana Lane Percent Interior Lighting 100.00 Range/Oven Fuel Natural gas Albany, NY 12204 Percent Garage Lighting 100.00 Clothes Dryer Fuel Natural gas 518-221-3240 . Refrigerator(kWh/yr) 408 Clothes Dryer CEF 2.32 sgrajny@nycap.rr.com Dishwasher Energy Factor 0.46 Ceiling Fan (cfm/Watt) 0.00 Certified Energy Rater: REM/Rate- Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RS° HERS PERFORMANCE HE(1111IndexMore Energy ENERGY - 150 4 140 — Existing i, 130 RAT I N G Homes ' 120 1'° CERTIFICATE Standard 100 New Home , 90 so 70 60 This Home 50 53 40 in 30 . 20 Zero Energy 10 Home 0 - �i� Less Energy Estimated Annual Energy Cost Estimated Annual Energy Consumption 2000 1,769_ 120.0 101.0 >,100.0 — L 1500 - 80.0 62.0 1000 428 748 448 i m 60.0-' 0.0 40.0 14.0 23.0 54 91 500 , i- 1_- 0 y 20.0 ` _.. 1.0mom _�- - 0.0 on on on Q. N v c c c a u on i on on on a . is i-+ N Q .- 0 1— c3 .� col Q I— _ o a)U = in a = v = `in > }, .con o U n a a_n o a, J a J a in Address 24 Wooden Lane Annual Estimates* • Stan Grajny, PE Queensbury, NY 12804 Electric(kWh): 6291 Grajny Consulting LLC House Type Single-family detached Natural gas(Therms): 799 80 Andriana Lane Cond. Area 2944 sq. ft. CO2 emissions(Tons): 7 Certified Rater Stan Grajny, PE Rating No. 0311186 Annual Savings**: $1491 Rater ID 5609922 Issue Date May 11, 2018 * Based on standard operating conditions Registry ID 617316826 Certification Inspected and Tested ** Based on a HERS 130 Index Home Rating Date 2018/05/10 Signature REM/Rate- Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. ©1985-2017 Noresco, Boulder,Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. • ENERGY STAR® CERTIFIED NEW HOME NERGY STAR Builder Name: Michaels Group Homes Rating Company: Grajny Consulting, LLC Permit Date/Number:2018 Rater Identification Number: 5609922 Home Address: 24 Wooden Lane Rating Date: 2018/05/10 Queensbury, NY 12804 Version: 3.1 Standard Features of an ENERGY STAR Certified New Home Your ENERGY STAR certified new home has been designed, constructed, and independently verified to meet rigorous requirements for energy efficiency set by the U.S. Environmental Protection Agency(EPA), including: Thermal Enclosure System Water Management System A complete thermal enclosure system that 010\," A comprehensive water management system includes comprehensive air sealing,quality- to protect roofs,walls,and foundations. installed insulation and high-performing [� windows to deliver improved comfort and --� u Flashing,a drainage plane,and site grading to (r lower utility bills. move water from the roof to the ground and Air Infiltration Test: Htg: 1129 Clg:1129 CFM50 then away from the home. Primary Insulation Levels: Water-resistant materials on below-grade walls and underneath Ceiling:R-49.0 FndWall:R-19.0 slabs to reduce the potential for water entering into the home. AGWall:R-21.0 Floor:R-30.0 Slab:R-0.0,R-0.0 Management of moisture levels in building materials during Primary Window Efficiency: construction. U-Value:0.300,SHGC:0.290 Heating,Cooling,and Ventilation System Energy Efficient A high-efficiency heating,cooling system, Lighting and Appliances i and ventilation system that is designed and Energy efficient products to help reduce utility -.Or j installed for optimal performance. bills,while providing high-quality performance. Total Duct Leakage: ENERGY STAR Qualified Lighting: 100% 231.00 CFM25. ENERGY STAR Qualified Appliances and Fans: Duct Leakage to Outdoors: Refrigerators: 1 Dishwashers:1 9.00 CFM25. Ceiling Fans:0 Exhaust Fans:1 Primary Heating(System Type•Fuel Type•Efficiency): Primary Water Heater(System Type•Fuel Type r Efficiency): Fuel-fired air distribution,Natural gas,95.0 AFUE. Conventional,Natural gas,0.70 EF,50.0 Gal. Primary Cooling(System Type•Fuel Type•Efficiency): . Air conditioner,Electric,13.0 SEER. HERS'Index The certificate n a summary of Tthe includng its Homeoerfeaturescontributeearningthe Energy Rating System(HERS)score,as determined through independent inspection and verification performed by a trained professional.The home Energy Rating System is a nationally-recognized uniform measurement of the energy efficiency of homes. Zero Energy Reference ExistingNote that when a home contains multiple performance levels for apaNcular feature(e.g.,window efficiency or insulation levels),tire predominant value is shown.Also,homes may be certified to earn the ENERGY STAR Home Home Homes using a sampling protocol,whereby one home is randomly selected from a set of homes for representative t� inspections and testing.In such cases,the features found in each home within the set are intended to meet or Hi �- exceed the values presented on this certificate.The actual values for your home may differ,but offer equivalent G i I1 '�lrJ/\) or better performance. .A1111111111 This certificate was printed using REMIRafe-v15.4.2. 0 o 0 o a o 0 0 0 0 F+ (+ r~i w A I"i ©1985-2017 Noresco,Boulder,Colorado. Less ca o 0 0 0 o More Energy Energy 1111 This Home Learn more at www.energystar.govlhomefeatures 02013 arsner . 308.12-1-45 RC-000799-20 Michaels Grou 17 24 Wooden Lanes Home LLC SFD w/gas fp , Lot 20 1939 s.f., Gar 759 s.f. Ec� � od � � 11", Lai 017DEC 2 9 2 TOWN ONG&DO EENSBURY BUILD .. S _ - S 51036' 55° E ... rT, 657.29' � 00 r— JILu FILE COPY ,� _ / _� LOT 20 o _ L 95697,4 Sq. Feet � � 4) R� 2.20 Acres �4 Cep ,q S / ## e 464 3 6 , Map Reference: �`27„ Map Of Proposed Subdivision Made For PERi,"IT PLOT PLAN Laric Development LLC I HAVE PERSONALLY MEASURED THE DISTANCE Dated-'April 10 2003 FRONT THr r^OPERTY LINES TO THE 3 PROE IJCTURE(S)Oj G ZGN LaRevised-, January4 2014 � DIVBVan Dusen a Sieves - j Z '� 4) > 2014, Plat C_349 x Filed.` March 3 si�r�AT E DA A � � � p O 0 0 Map Reference. Map of a Proposed Subdivision Made for Lark Development,LLC Dated.•April 10;2003 Last Revised:January 4,2014 By:Van Dusan&Stoves LOT 22 Hied:March 3,2014,Plot C,349 Notes: I-Surveyed parcel is subject to easements,covenants,and agreements of record. 2.Surveyed parcel is subject to conditions of the subdivision approval. *100.30' 1*375.00' W C, 1 15.0' W 3 .0 LOT 21 39.0 2 5tory Window Weil Wood',Frame House CD A135OWTION 31. Q 3.5 TRENCHES 3 @ 50'EA. 12.5 7.5 1 1000 GAL. 5EFTIC TANK D15TRJBUTION Bpx j gyp' LOT 19 LOT 20 Area 95697.4:t Sq. Feet 2.2± Acres LOT 18 F NA 315.761 W S 83049'280 ISEPTIC SYSTEM AS BUILT BY NACE ENGINEERINGI Dote: May 03, 2018 DuULAIMIOWED ALTMT*NOR AMMON TO A50W& Scale 1"=501 on MA?BeAMNO A UCCW-CO LAW V"CVM SM 5 A Map of a Survey made for V"ATION Of 5EMON 7209.W"%A51ON 4 OF THE & NEW YORK 5TATE eMCATK)N LAW 'MY COMS rROM INC OVJGWAL Or M5 5LRM MARMO WMI AN ORMM Of TM LAND 5LftCY0F6 Steves 5M%iALL PC COWWOMO TO 6C VAUD T1=COMM' 1=*3CAAON5 WrWOD HUZM%W"nW S- 1 Th1rP SWi&WA5"VAUD IN AOOORDA=WMI nt MT04 CQVt Of OMA~sunledX5#"Mi Michaels , Group Homes 1W Tht NEIN YOM 5TAX&%5OQATPON OF FRNt55"M Lari. d Surveyors LAW 5UMICYM.SAID OMMATION5 MAU ftJN OWY � TO T"C nR"MR WNOM THE%XM 15 rWAAW,AND SHEET I OF 1 ON .5 "w To n"Tu cDw..amw-wAL Town of Queensbury, Warren County, New York AG&CY AND IZNVING INSMUMN LeMD h0TON.AND 169 Haviland Road Queensbury, New York 12604 TO THC THC AMG OF TW WOW MOPTUnON.- 1 514118 SEPTIC AS BUILT MICHAEL5 GROUP HOMES (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 99-241 Lot 20