Loading...
1.1 1.1 SETPH.VAR\Ellis-Holding Tank Replacement System&Setbacks-4-2-18 RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF JOHN ELLIS RESOLUTION NO.: ,2018 INTRODUCED BY: WHO MOVED ITS ADOPTION SECONDED BY: WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal Ordinance, and WHEREAS, John Ellis (Applicant) has applied to the Local Board of Health for variances from Chapter 136, §136-11 which requires an applicant to obtain a variance for a holding tank, as the Applicant wishes to replace his wastewater system by installing a holding tank system consisting of two (2) holding tanks each with a capacity of 1,500 gallons, thus meeting the required total capacity of 3,000 gallons, and WHEREAS, the Applicant has also applied for additional variances from Chapter 136 to allow placement of such holding tanks: 1. 6' from the building in lieu of the required 10' setback; 2. 13' from the existing well in lieu of the required 50' setback; and 3. 45' from the well on the west side in lieu of the required 50' setback; on property located at 56 Sunnyside North in the Town of Queensbury, NOW, THEREFORE, BE IT RESOLVED, that the Town of Queensbury Local Board of Health will hold a public hearing on Monday, April 16t'', 2018 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider John Ellis' sewage disposal variance application concerning property located at 56 Sunnyside North in the Town of Queensbury and bearing Tax Map No.: 279.17-2-35 and at that time all interested persons will be heard, and BE IT FURTHER, RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500 feet of the property as required by law. Duly adopted this 2nd day of April, 2018,by the following vote: AYES NOES ABSENT: SEWER\Ellis-Holding Tank&Setbacks-4-16-18 NOTICE OF PUBLIC HEARING IN ACCORDANCE WITH TOWN OF QUEENSBURY ON-SITE SEWAGE DISPOSAL ORDINANCE CHAPTER 136,NOTICE IS HEREBY GIVEN THAT THE TOWN OF QUEENSBURY LOCAL BOARD OF HEALTH WILL CONDUCT A PUBLIC HEARING ON MONDAY, APRIL 16TH, 2018 AT 7:00 P.M. AT THE QUEENSBURY ACTIVITIES CENTER, 742 BAY ROAD, QUEENSBURY TO CONSIDER AN APPLICATION BY JOHN ELLIS FOR SEWAGE DISPOSAL VARIANCES TO REPLACE HIS WASTEWATER SYSTEM BY INSTALLING A HOLDING TANK SYSTEM CONSISTING OF TWO (2) HOLDING TANKS EACH WITH A CAPACITY OF 1,500 GALLONS, THUS MEETING THE REQUIRED TOTAL CAPACITY OF 3,000 GALLONS, AND PLACE SUCH HOLDING TANKS: 1. 6' FROM THE BUILDING IN LIEU OF THE REQUIRED 10' SETBACK; 2. 13' FROM THE EXISTING WELL IN LIEU OF THE REQUIRED 50' SETBACK; AND 3. 45' FROM THE WELL ON THE WEST SIDE IN LIEU OF THE REQUIRED 50' SETBACK; ON PROPERTY LOCATED AT 56 SUNNYSIDE NORTH IN THE TOWN OF QUEENSBURY, (TAX MAP NO.: 279.17-2-35). AT THIS PUBLIC HEARING ALL INTERESTED PERSONS WILL BE HEARD. PUBLICATION DATE: APRIL ,2018 CAROLINE H. BARBER TOWN CLERK TOWN OF QUEENSBURY 169 Haviland Road Queensbury, NY 12804 Phone:(518)745-0307 Hutchins Engineering Fax: (518)745-0308 March 27, 2018 Town of Queensbury Town Board Board of Health 742 Bay Road Queensbury NY 12804 Re: John Ellis 56 Sunnyside Road North Tax Map ID: 279.17-2-35 Dear Supervisor Strough & Town Board Councilmen: This office represents the Mr. John Ellis with respect to the pursuit of wastewater variances for a holding tank system installation at his property located on Lake Sunnyside. Presently the home is served by a unknown sized seepage pit which is far from adequate and they desire to bring the parcel up to the town's current on-site wastewater system standards. Given the terrain and site constraints, it is not feasible to install an absorption field system, therefore we are pursuing the holding tank system. Presently the house is served by a seepage pit, which is far from adequate and the applicants desire to install (2) 1500-gallon tanks to support the existing 2 bedroom cottage. Relief is requested for the installation of the holding tank system itself and setback relief is requested from the applicant's home, well, and westerly neighboring well (parcel is owned by the applicant); these requests are detailed in the application. Enclosed please find ten submission packages for this project. We respectfully request, if possible, that this item be placed upon the agenda of the next town board meeting. Please contact me if you have any questions or if you require additional information. Best Re.ards, Th•mas R. Center Jr., P.E. Associate- Design Engineer Cc: John Ellis Town of Queensbury Building & Codes Office Use Only Received: SEPTIC VARIANCE APPLICATION Tax Map ID: Submittal: 1 original&8 copies of the completed application package Permit No.: 3;moi pY` , Permit Fee: Approvals: I L ••f•;.:; �, JOHN ELLIS HUTCHINS E ` RING Owner Owner's Agent Address 54 SUNNYSIDE ROAD Address 169 HAVILAND Re • 01 F. QUEENSBURY,NY QUEENSBURY,NY 1280-4---- Phone 518-932-5701 Phone 518-796-2515 Directions to Site: BAY ROAD TO SUNNYSIDE NORTH Distance from well on property to septic system(if applicable) UNKNOWN feet Is it possible to install a conforming septic system on this property? 1 I Yes 1:1 No If YES, please explain and attach diagram: Does proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? Q Yes n No If NO,please explain: PROPSOED HOLDING TANK SYSTEM WILL REQUIRE A VARIANCE TO BE WITHIN 50 FT OF THE NEIGHBOR TO THE WEST(PROPERTY OWNERS CURRENT RESIDENCE) Is proposed system to be installed over a parking area? 11 Yes ✓❑ No Section of the Sanitary Sewage Ordinance from which you are seeking the variance: (example: leaching system will be 89 ft. from well in lieu of required 100 ft.separate distance): REQUEST TO INSTALL HOLDING TANK SYSTEM REQUEST TO INSTALL HOLDING TANKS 6'FROM BUILDING-4'OF RELIEF REQUESTED REQUEST TO INSTALL HOLDING TANKS 13'FROM EX.WELL-37'OF RELIEF REQUESTED REQUEST TO INSTALL HOLDING TANKS 45'FROM WELL TO THE WEST-5'OF RELIEF REQUESTED Town of Queensbury Building&Codes Septic Variance Application 518-761-8256 List the names, parcel addresses,and tax map numbers of all adjoining property owners. You may obtain tax map numbers from the Assessors Office as well as the names and addresses: North Name LYNNE FISH Address 59 SUNNYSIDE NORTH Tax Map ID 279.17-1-1.1 South Name: NONE Address Tax Map ID East Name: KIRK BARTON Address SUNNYSIDE NORTH Tax Map ID 279.17-2-34 West Name: JOHN ELLIS Address 54 SUNNYSIDE NORTH Tax Map ID 279.17-2-36 OWNER STATEMENT I,we do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 56 SUNNYSIDE ROAD NORTH I,we realize that putting the well, septic tank,or leaching system less than the required 5o feet from the WELL may increase risk of pollution. Owner-Print Name: JOHN ELLIS Owner-Signature: r- Date: 3/27/18 6) NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) I,we do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 54 SUNNYSIDE RD NORTH I,we realize that putting the septic tank or leaching system less than the required 50 feet from the WELL may increase risk of pollution. Neighbor or Tenant-Print Name: JOHN ELLIs Neighbor or Tenant-Signature: Pi Date: 3/27/18 Town of Queensbury Building&Codes Septic Vari nc pplication 518-761.8256 PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION: 1. Location map showing the site within the Town of Queensbury; 2. Plot plan showing existing and proposed features of the property including: a) Lot dimensions b) North arrow and scale: 1 inch=40 feet c) Location&dimensions of existing and proposed buildings, showing setback distances and uses d) Parking layout to scale(if applicable) e) Physical features(streets,steep slopes, lakes,wetlands,etc.) f) Location of all wells and septic systems on neighboring properties g) Adjacent ownership h) All properties within 500 feet. A sample plot plan and location are shown below _�,' \ % I /�' Sample location Map s 1 .—A 1 ( �/• as "'oyr, 1 j}�qa It::J l /w^ J 4j(} 41* art,,:,+ i '� imarg 1 Li /I/ -,i1',- __,---- , ,,,,,,„...,,,,, ,,, ....,, ; ,..„,,,,, ,... ., [Wry Pata,IX r i S ". /V'R' HOUSE yF!—� Wil: .4s t- —.—yR�.5.) I Cy— 1 61 r ,. �� a / 1 1 �� Y•:) :q, f/ 0 SfDI'C / < •� 1yc f ' i A r v �` �.3 1 \ L i Totm of Quafnsbu y i; ( tai „ �a Town Offices 4.<04•40°J,..a ,I I 0) r:.—ri/ ,,.',° I =sem Y I 111171,M1.11 -1 91Vl�Fh ----- - ,..........____----.7"---.. fes.— Nr ---- 1 4 a a..1. . e " if "!bt w SGk Town of Queensbury Building&Codes Septic Variance Application 518-761-8256 617.20 Appendix B Short Environmental Assessment Form Instructions for Completing Part I-Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding,are subject to public review,and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency;attach additional pages as necessary to supplement any item. Part 1-Project and Sponsor Information JOHN ELLIS Name of Action or Project: 56 SUNNYSIDE ROAD NORTH HOLDING TANK SYSTEM Project Location(describe,and attach a location map): 56 SUNNYSIDE ROAD NORTH Brief Description of Proposed Action. INSTALL REPLACEMENT HOLDING TANK SYSTEM Name of Applicant or Sponsor: Telephone: 518-932-5701 JOHN ELLIS E-Mail: Address: 54 SUNNYSIDE ROAD NORTH City/PO: State: Zip Code: QUEENSBURY NY 12804 I.Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO YES administrative rule,or regulation? If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that I-' ❑ may be affected in the municipality and proceed to Part 2. If no,continue to question 2. 2. Does the proposed action require a permit,approval or funding from any other governmental Agency? NO YES If Yes,list agency(s)name and permit or approval: TOQ BOARD OF HEALTH HOLDING TANK VARIANCE El Q 3.a.Total acreage of the site of the proposed action? 0.15 acres b.Total acreage to be physically disturbed? LESST"^"0I acres c.Total acreage(project site and any contiguous properties)owned 0.27 or controlled by the applicant or project sponsor? acres 4. Chec land us c rh t occur on,adjoining r the propc.a -action. rban rural(non-agriculture) ndustrial ;ommercial ✓Residential(suburban) ❑Forest iigricultureAquatic I ether(specify): 'arklan Page 1 of 4 5. Is the proposed action, NO YES N/A a.A permitted use under the zoning regulations? 1'� b.Consistent with the adopted comprehensive plan? ✓ 6. Is the proposed action consistent with the predominant character of the existing built or natural NO YES landscape? ❑ t ,1 7. Is the site of the proposed action located in,or does it adjoin,a state listed Critical Environmental Area? NO YES If Yes,identify: LAKE SUNNYSIDE El El 8. a.Will the proposed action result in a substantial increase in traffic above present levels? NO YES b.Are public transportation service(s)available at or near the site of the proposed action? c.Are any pedestrian accommodations or bicycle routes available on or near site of the proposed action? �/ n 9.Does the proposed action meet or exceed the state energy code requirements? NO YES If the proposed action will exceed requirements,describe design features and technologies: El 10. Will the proposed action connect to an existing public/private water supply? NO YES If Yes,does the existing system have capacity to provide service? 0 NO 0 YES If No,describe method for providing potable water: 111EXISTING WELL 11.Will the proposed action connect to existing wastewater utilities? NO YES If Yes,does the existing system have capacity to provide service? 0 NO 0 YES If No,describe method for providing wastewater treatment: REPLACEMENT HOLDING TANK SYSTEM I�/ 12. a.Does the site contain a structure that is listed on either the State or National Register of Historic NO YES Places? b.Is the proposed action located in an archeological sensitive area? 13.a.Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO YES wetlands or other waterbodies regulated by a federal,state or local agency? / b.Would the proposed action physically alter,or encroach into,any existing wetland or waterbody? v If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres: 14,14ntify the typical habitat types that occur on,or are likely to be found on the project site. Check all that apply: ✓ Shoreline 0 Forest 0 Agricultural/grasslands 0 Early mid-successional 0 Wetland 0 Urban QSuburban 15.Does the site of the proposed action contain any species of animal,or associated habitats,listed NO YES by the State or Federal government as threatened or endangered? rj'j n 16.Is the project site located in the 100 year flood plain? NO I YES ✓ I El 17.Will the proposed action create storm water discharge,either from point or non-point sources? NO YES If Yes, El Ela.Will storm water discharges flow to adjacent properties? 0 NO 0 YES b.Will storm water discharges be directed to established conveyance systems(runoff and storm drains)? If Yes,briefly describe: 0 NO 0 YES [] n Page 2 of 4 18.Does the proposed action include construction or other activities that result in the impoundment of NO YES water or other liquids(e.g.retention pond,waste lagoon,dam)? If Yes,explain purpose and size: 1500 GAL.WASTEWATER HOLDING TANK SYSTEM E1 19.Has the site of the proposed action or an adjoining property been the location of an active or closed NO YES solid waste management facility? If Yes,describe: ❑ 20.Has the site of the proposed action or an adjoining property been the subject of remediation(ongoing or NO YES completed)for hazardous waste? If Yes,describe: I AFFIRM THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE THOMAS CENTER,PE HUTCHINS ENGINEERING 3/27/18 Applicant/sponsor name: Date: Signature: Part 2-Impact Assessment. The Lead Agency is responsible for the completion of Part 2. Answer all of the following questions in Part 2 using the information contained in Part 1 and other materials submitted by the project sponsor or otherwise available to the reviewer. When answering the questions the reviewer should be guided by the concept"Have my responses been reasonable considering the scale and context of the proposed action?" No,or Moderate small to large impact impact may may occur occur 1. Will the proposed action create a material conflict with an adopted land use plan or zoning regulations? 2. Will the proposed action result in a change in the use or intensity of use of land? 3. Will the proposed action impair the character or quality of the existing community? 4. Will the proposed action have an impact on the environmental characteristics that caused the establishment of a Critical Environmental Area(CEA)? 5. Will the proposed action result in an adverse change in the existing level of traffic or affect existing infrastructure for mass transit,biking or walkway? 6. Will the proposed action cause an increase in the use of energy and it fails to incorporate reasonably available energy conservation or renewable energy opportunities? 7. Will the proposed action impact existing: a.public/private water supplies? b.public/private wastewater treatment utilities? 8. Will the proposed action impair the character or quality of important historic,archaeological, architectural or aesthetic resources? 9. Will the proposed action result in an adverse change to natural resources(e.g.,wetlands, waterbodies,groundwater,air quality,flora and fauna)? Page 3 of 4 No,or Moderate small to large impact impact may may occur occur 10. Will the proposed action result in an increase in the potential for erosion,flooding or drainage problems? 11. Will the proposed action create a hazard to environmental resources or human health? Part 3-Determination of significance. The Lead Agency is responsible for the completion of Part 3. For every question in Part 2 that was answered"moderate to large impact may occur",or if there is a need to explain why a particular element of the proposed action may or will not result in a significant adverse environmental impact,please complete Part 3. Part 3 should,in sufficient detail,identify the impact,including any measures or design elements that have been included by the project sponsor to avoid or reduce impacts. Part 3 should also explain how the lead agency determined that the impact may or will not be significant.Each potential impact should be assessed considering its setting,probability of occurring, duration,irreversibility,geographic scope and magnitude. Also consider the potential for short-term,long-term and cumulative impacts. o Cheek this box if you have determined,based on the information and analysis above,and any supporting documentation, that the proposed action may result in one or more potentially large or significant adverse impacts and an environmental impact statement is required. o Check this box if you have determined,based on the information and analysis above,and any supporting documentation, that the proposed action will not result in any significant adverse environmental impacts. Name of Lead Agency Date +T Print or Type Name of Responsible Officer in Lead Agency Title of Responsible Officer Signature of Responsible Officer in Lead Agency Signature of Preparer(if different from Responsible Officer) Page 4 of 4 Signature Page This page includes the Authorization to Act as Agent Form, engineering Fee Disclosure, Authorization for Site Visits, Other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: Owner's Name: JOHN ELLIS Designates: HUTCHINS ENGINEERING as agent regarding Septic Variance for Tax Map ID; 279.17-2-35 OWNER'S SIGNATURE: Date: r 3/27/18 Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc.as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By signing this page and submitting the application materials attached, herein, the Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from application, and that minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. ✓I, the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed the checklist. PRINT NAME OF OWNER: JOHN ELLIS SIGNATURE OF OWNER: C /. DATE: 3/ 7/ PRINT NAME OF AGENT: HUTCHINS ENGINEERING SIGNATURE OF AGENT: DATE: 3/27/18 Town of Queensbury Building&Codes Septic Variance Application 518-761-8256 DEED REFERENCE: 1) BARBARA DENIG AS ADMINISTRATRIX OF THE ESTATE OF FRANK ANTHONY COLOTTI JR., TO JOHN ELLI% FILED IN THE OFFICE OF THE WARREN COUNTY CLERK IL WWW AMA AT Pe(F aG- neTFn CFPnWRFR 29. 2006. MAI 1) 'MAF DATEC NOT 1) BASE 2) NORTF 3) TOGET THE F 4) SUBJE 5) ISITHi ANY ! 6) SUBJE REGAF 7) UNAU1 SURVE NEW 8) ONLY TRUE 9) CERTIF IN AC AOOP' THE C PREP) INSTIT NOT T 10) THE I KNOW ENCRC NOT C WASTEWATER SYSTEM DESIGN 2 -BEDROOM DESIGN WATER SAVING FIXTURES - REPLACE EXIST. FIXTURES AS NEEDED (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 220 GPD HOLDING TANK DESIGN ,� s35•24i 2s„ E b NYSDOH SIZING - 5 -DAYS DESIGN FLOW - 1100 GALS Y f f TOWN OF QUEENSBURY HOLDING TANK VOLUME REQUIRED:4a .4 f'J \ cL -§136-11a 3000 GAL B. (2) ' 01, € t t G' LAKE INSTALL (2) 1500 GAL POLYPROPYLENE TANKS IN SERIES � PROPERTY LINE s r q5V x 6UNNYSIDE 3000 GAL TOTAL TO BE PROVIDED L. 736 P. 260 � �J�� p 33'± ALONG LAKE POTABLE WATER SUPPLY IS EXISTING ON-SITE WELL 10' tJs 50' 10' f - MAINTAIN 50' MINIMUM SETBACK TO HOLDING TANKS � hwrp�'m:'°°T rr dock - RELAY TO $E INSTALLED ON WATER PUMP CIRCUIT TO SHUT DOWN SYSTEM MATERIAL SPECIFICATIONS G{Ft $ l - ".. �� �allxY. R :.� . �f�$i e3 �I f.Qf, •: HOUSE SEWER PIPE WATER SUPPLY TO HOUSE WHEN ACTIVATED BY WARNING/SHUT �� tt 4 " fi�don F91 °hw;.:..F"<, DOWN ALARM ON PANEL PIPING TO BE 4” SDR -35 OR SCH-40 PVC. INSTALL WITH 1/4" PER FOOT Y .,v ohw SITE LOCATION LOCATION MAP To HOLDING TANK ALARM NOTES ALARM PANEL CONTROLS SHALL BE SJE RHOMBUS TANK ALERT DUO HOLDING TANK CONNECTOR PIPE ALARM SYSTEM OR EQUIVALENT, AND PROVIDE THE FOLLOWING IRF t1 �j MONITORING AND CONTROL FUNCTIONS: G GRAPHIC SCALE WHEN LEVEL OF TANK REACHES 509 CAPACITY, ALARM WILL INDICATE "TANK HIGH LEVEL" WITH A YELLOW LIGHT ON ALARM PANEL. WHEN LEVEL OF TANK REACHES 959 CAPACITY, AUDIBLE ALARM WILL SOUND AND RED LIGHT WILL FLASH, INDICATING "TANK SHUTOFF LEVEL". ELECTRICAL INTERLOCK SHALL BE INSTALLED TO DISABLE WATER SUPPLY UPON REACHING "TANK SHUTOFF LEVEL". SYSTEM WILL RESET AFTER HOLDING TANKS ARE PUMPED DOWN TO BELOW THE ACTUATION LEVEL OF "TANK HIGH LEVEL" ALARM. AN ELECTRICAL INSPECTION BY A CERTIFIED ELECTRICAL INSPECTION AGENCY IS REQUIRED AFTER INSTALLATION. ELECTRICAL INSPECTION SEAL IS TO BE AFFIXED TO ALARM CONTROL PANEL. VARIANCE SUMMARY THE FOLLOtMNG RELIEF IS REQUESTED FROM THE TOWN OF QUEENSBURY CHAPTER 136 SEWERS AND SEWAGE DISPOSAL: HOLDING TANK INSTALLATION - §136-11 A. - INSTALL TWO 1500 GALLON WASTEWATER HOLDING TANKS HORIZONTAL SEPARATION DISTANCES - §136-9 D. - BUILDING SETBACK - 10' REQUIRED, 6' PROPOSED - 4' OF RELIEF REQUESTED - NEIGHBORING WELL SETBACK - 50' REQUIRED, 45' PROPOSED - 5' OF RELIEF REQUESTED - EXISTING WELL SETBACK 50' REQUIRED, 13' PROPOSED - 37' OF RELIEF REQUESTED 9• ` ,� s35•24i 2s„ E W RSTEW ATER SYSTEM SETBACK SCHEDULE .Bends n/f � .4 f'J LAKE Fung Mei Ling & John E. Ellis /ti° �� r , PROPERTY LINE WELLS 6UNNYSIDE HOUSE L. 736 P. 260 � �J�� p 33'± ALONG LAKE HOLDINGTANK 10' S0' 50' 10' N49'1733 W IPF f� rr dock SYSTEM MATERIAL SPECIFICATIONS HOUSE SEWER PIPE PIPING TO BE 4” SDR -35 OR SCH-40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE. HOLDING TANK CONNECTOR PIPE IRF t1 �j PIPING TO BE 4" SDR -35 OR SCH-40 PVC. INSTALL LEVEL G GRAPHIC SCALE j� LA BACKFILL MATERIAL BACKFILL TO BE GRANULAR SAND BACKFILL MATERIAL WITH NO PARTICLES 20 0 10 20 40 80 GREATER THAN 1". ( IN FEET) APPROXIMATE POLYETHYLENE EXTENSION POLYETHYLENE EXTENSION FINISH GRADE TO GRADE WITH TAMPER TO GRADE WITH TAMPER 1 inch = 20 ft. RESISTANT ACCESS COVER RESISTANT ACCESS COVER 1500 GALLON 12"t 4" PVC SDR -35 INJECTION MOLDED 12"f CONNECTOR PIPE POLYPROPYLENE SEPTIC TANK 4" SDR -35 PVCINSTALLED LEVEL INSTALLED AS HOLDING TANK 3 INLETLIQUID LEVEL SEALED WATERTIGHT TAX MAP # 279.17-2-35 — MIN. SLOPE r I LIQUID LEVEL 1/4" PER FOOT 16" INSTALL FLOAT SWITCHES TO OPERATE ALARM PANEL ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. 509 CAPACITY AT INDICATED LEVELS WATERTIGHT SLEEVE (1500 GAL) 959 CAPACITY AND SEAL (TIP.) WARNING LEVEL (4275 GAL) ALARM LIGHT ON ALARM/SHUT DOWN 1500 GALLON ALARM ON INJECTION MOLDED _.. POLYMER SEPTIC TANK <:'., < - A INSTALLED SHO HOLDING G TANK .4 Y FN 7EA GRAVEL 6"1 PEA GRAVEL 0 ISSUED FOR WASTEWATER VARIANCE 3/2; HOLDING TANKS IN SERIES DETAIL No. Revisions Da NTS HOLDING TANK NOTES HOLDING TANK PLAN ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK RUBBER GASKETS SHALL BE INSTALLED IN ALL INLETS AND OUTLETS. prepared for D,FSafely, F INJECTION MOLDED POLYPROPYLENSTATE E�EAS MANUFACTURED NT OF HEALTH "BY NFILTRATORD SHALL BE OWATER TECHNOLOGIES, TANKS ARE NOT APPROPRIATE TO BE INSTALLED IN TRAFFIC AREASg John Ellis �/ New �rk MODEL IM -1530 OR EQUIVALENT. ®I - Dig TANKS TO BE BACKFILLED KITH CLEAN SAND FILL; NATIVE COBBLY, 56 Sunnyside Rodd North IM Can Before You ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BOULDERY SOILS ARE NOT ACCEPTABLE AS BACKFILL MATERIAL. ® wait The Required Time IM Confirm Utility Response BASE. WHERE EXIS77NG SOIL CONDITIONS ARE UNSUITABLE, A 12 MIN. Town of Queensbury, Warren County, New York Respect The Marks COURSE OF CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE ALL SEAMS, PENETRATIONS, & ACCESS COVERS MUST BE MAINTAINED Drawn: TRC Checke : GTH Scaler 1"=10' Date: 2/5/18 IM Dig with Care A STABLE BASE. WATER71GHT BY INSTALLER. FIELD COAT ADDITIONAL PENETRATIONS AS 800•962.7962 NECESSARY WITH WATERTIGHT SEALANT. 169 Haviland Road www.digsafelynewyork.com Queensbury, NY 12804 291248-01- (518) 745-0307 Phone �iUtCi11t1S Engineering Itl@@Ch g g (518) 745-0308 Fax