1.1 1.1
SETPH.VAR\Ellis-Holding Tank Replacement System&Setbacks-4-2-18
RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL
VARIANCE APPLICATION OF JOHN ELLIS
RESOLUTION NO.: ,2018
INTRODUCED BY:
WHO MOVED ITS ADOPTION
SECONDED BY:
WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is
authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal
Ordinance, and
WHEREAS, John Ellis (Applicant) has applied to the Local Board of Health for variances
from Chapter 136, §136-11 which requires an applicant to obtain a variance for a holding tank, as the
Applicant wishes to replace his wastewater system by installing a holding tank system consisting of two
(2) holding tanks each with a capacity of 1,500 gallons, thus meeting the required total capacity of
3,000 gallons, and
WHEREAS, the Applicant has also applied for additional variances from Chapter 136 to allow
placement of such holding tanks:
1. 6' from the building in lieu of the required 10' setback;
2. 13' from the existing well in lieu of the required 50' setback; and
3. 45' from the well on the west side in lieu of the required 50' setback;
on property located at 56 Sunnyside North in the Town of Queensbury,
NOW, THEREFORE, BE IT
RESOLVED, that the Town of Queensbury Local Board of Health will hold a public hearing
on Monday, April 16t'', 2018 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road,
Queensbury, to consider John Ellis' sewage disposal variance application concerning property located
at 56 Sunnyside North in the Town of Queensbury and bearing Tax Map No.: 279.17-2-35 and at that
time all interested persons will be heard, and
BE IT FURTHER,
RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town
Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice
to neighbors located within 500 feet of the property as required by law.
Duly adopted this 2nd day of April, 2018,by the following vote:
AYES
NOES
ABSENT:
SEWER\Ellis-Holding Tank&Setbacks-4-16-18
NOTICE OF PUBLIC HEARING
IN ACCORDANCE WITH TOWN OF QUEENSBURY ON-SITE SEWAGE DISPOSAL
ORDINANCE CHAPTER 136,NOTICE IS HEREBY GIVEN THAT THE TOWN OF QUEENSBURY
LOCAL BOARD OF HEALTH WILL CONDUCT A PUBLIC HEARING ON MONDAY, APRIL
16TH, 2018 AT 7:00 P.M. AT THE QUEENSBURY ACTIVITIES CENTER, 742 BAY ROAD,
QUEENSBURY TO CONSIDER AN APPLICATION BY JOHN ELLIS FOR SEWAGE DISPOSAL
VARIANCES TO REPLACE HIS WASTEWATER SYSTEM BY INSTALLING A HOLDING TANK
SYSTEM CONSISTING OF TWO (2) HOLDING TANKS EACH WITH A CAPACITY OF 1,500
GALLONS, THUS MEETING THE REQUIRED TOTAL CAPACITY OF 3,000 GALLONS, AND
PLACE SUCH HOLDING TANKS:
1. 6' FROM THE BUILDING IN LIEU OF THE REQUIRED 10' SETBACK;
2. 13' FROM THE EXISTING WELL IN LIEU OF THE REQUIRED 50' SETBACK;
AND
3. 45' FROM THE WELL ON THE WEST SIDE IN LIEU OF THE REQUIRED 50'
SETBACK;
ON PROPERTY LOCATED AT 56 SUNNYSIDE NORTH IN THE TOWN OF QUEENSBURY,
(TAX MAP NO.: 279.17-2-35).
AT THIS PUBLIC HEARING ALL INTERESTED PERSONS WILL BE HEARD.
PUBLICATION DATE: APRIL ,2018
CAROLINE H. BARBER
TOWN CLERK
TOWN OF QUEENSBURY
169 Haviland Road
Queensbury, NY 12804
Phone:(518)745-0307
Hutchins Engineering
Fax: (518)745-0308
March 27, 2018
Town of Queensbury Town Board
Board of Health
742 Bay Road
Queensbury NY 12804
Re: John Ellis
56 Sunnyside Road North
Tax Map ID: 279.17-2-35
Dear Supervisor Strough & Town Board Councilmen:
This office represents the Mr. John Ellis with respect to the pursuit of wastewater variances for a
holding tank system installation at his property located on Lake Sunnyside. Presently the home
is served by a unknown sized seepage pit which is far from adequate and they desire to bring
the parcel up to the town's current on-site wastewater system standards. Given the terrain and
site constraints, it is not feasible to install an absorption field system, therefore we are pursuing
the holding tank system.
Presently the house is served by a seepage pit, which is far from adequate and the applicants
desire to install (2) 1500-gallon tanks to support the existing 2 bedroom cottage.
Relief is requested for the installation of the holding tank system itself and setback relief is
requested from the applicant's home, well, and westerly neighboring well (parcel is owned by
the applicant); these requests are detailed in the application.
Enclosed please find ten submission packages for this project. We respectfully request, if
possible, that this item be placed upon the agenda of the next town board meeting. Please
contact me if you have any questions or if you require additional information.
Best Re.ards,
Th•mas R. Center Jr., P.E.
Associate- Design Engineer
Cc: John Ellis
Town of Queensbury Building & Codes Office Use Only
Received:
SEPTIC VARIANCE APPLICATION Tax Map ID:
Submittal: 1 original&8 copies of the completed application package Permit No.: 3;moi pY` ,
Permit Fee:
Approvals: I L
••f•;.:; �,
JOHN ELLIS HUTCHINS E ` RING
Owner Owner's Agent
Address 54 SUNNYSIDE ROAD Address 169 HAVILAND Re •
01 F.
QUEENSBURY,NY QUEENSBURY,NY 1280-4----
Phone 518-932-5701 Phone 518-796-2515
Directions to Site: BAY ROAD TO SUNNYSIDE NORTH
Distance from well on property to septic system(if applicable) UNKNOWN feet
Is it possible to install a conforming septic system on this property? 1 I Yes 1:1 No
If YES, please explain and attach diagram:
Does proposed system meet setback requirements for distance from wells&septic systems on neighboring properties?
Q Yes n No If NO,please explain: PROPSOED HOLDING TANK SYSTEM WILL REQUIRE A VARIANCE TO BE
WITHIN 50 FT OF THE NEIGHBOR TO THE WEST(PROPERTY OWNERS CURRENT RESIDENCE)
Is proposed system to be installed over a parking area? 11 Yes ✓❑ No
Section of the Sanitary Sewage Ordinance from which you are seeking the variance: (example: leaching system will be 89 ft.
from well in lieu of required 100 ft.separate distance):
REQUEST TO INSTALL HOLDING TANK SYSTEM
REQUEST TO INSTALL HOLDING TANKS 6'FROM BUILDING-4'OF RELIEF REQUESTED
REQUEST TO INSTALL HOLDING TANKS 13'FROM EX.WELL-37'OF RELIEF REQUESTED
REQUEST TO INSTALL HOLDING TANKS 45'FROM WELL TO THE WEST-5'OF RELIEF REQUESTED
Town of Queensbury Building&Codes Septic Variance Application 518-761-8256
List the names, parcel addresses,and tax map numbers of all adjoining property owners. You may obtain tax map numbers
from the Assessors Office as well as the names and addresses:
North Name LYNNE FISH
Address 59 SUNNYSIDE NORTH
Tax Map ID 279.17-1-1.1
South Name: NONE
Address
Tax Map ID
East Name: KIRK BARTON
Address SUNNYSIDE NORTH
Tax Map ID 279.17-2-34
West Name: JOHN ELLIS
Address 54 SUNNYSIDE NORTH
Tax Map ID 279.17-2-36
OWNER STATEMENT
I,we do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
56 SUNNYSIDE ROAD NORTH
I,we realize that putting the well, septic tank,or leaching system less than the required 5o feet from the
WELL may increase risk of pollution.
Owner-Print Name: JOHN ELLIS
Owner-Signature: r- Date: 3/27/18
6)
NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable)
I,we do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at:
54 SUNNYSIDE RD NORTH
I,we realize that putting the septic tank or leaching system less than the required 50 feet from the
WELL may increase risk of pollution.
Neighbor or Tenant-Print Name: JOHN ELLIs
Neighbor or Tenant-Signature: Pi Date: 3/27/18
Town of Queensbury Building&Codes Septic Vari nc pplication 518-761.8256
PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION:
1. Location map showing the site within the Town of Queensbury;
2. Plot plan showing existing and proposed features of the property including:
a) Lot dimensions
b) North arrow and scale: 1 inch=40 feet
c) Location&dimensions of existing and proposed buildings, showing setback distances and uses
d) Parking layout to scale(if applicable)
e) Physical features(streets,steep slopes, lakes,wetlands,etc.)
f) Location of all wells and septic systems on neighboring properties
g) Adjacent ownership
h) All properties within 500 feet.
A sample plot plan and location are shown below
_�,' \ % I /�' Sample location Map s
1
.—A 1 ( �/• as "'oyr,
1
j}�qa It::J l /w^ J 4j(} 41*
art,,:,+ i '� imarg
1 Li /I/ -,i1',- __,---- , ,,,,,,„...,,,,, ,,,
....,, ;
,..„,,,,, ,... ., [Wry Pata,IX
r i S ".
/V'R' HOUSE yF!—� Wil: .4s
t- —.—yR�.5.) I Cy—
1 61 r ,. �� a / 1 1 �� Y•:) :q,
f/ 0 SfDI'C / < •� 1yc f ' i A
r v �` �.3 1 \ L i Totm of Quafnsbu y
i; ( tai „
�a Town Offices
4.<04•40°J,..a ,I I 0) r:.—ri/ ,,.',°
I =sem Y
I 111171,M1.11 -1
91Vl�Fh ----- -
,..........____----.7"---.. fes.— Nr
---- 1 4
a
a..1. .
e "
if "!bt w SGk
Town of Queensbury Building&Codes Septic Variance Application 518-761-8256
617.20
Appendix B
Short Environmental Assessment Form
Instructions for Completing
Part I-Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses
become part of the application for approval or funding,are subject to public review,and may be subject to further verification.
Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully
respond to any item,please answer as thoroughly as possible based on current information.
Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful
to the lead agency;attach additional pages as necessary to supplement any item.
Part 1-Project and Sponsor Information
JOHN ELLIS
Name of Action or Project:
56 SUNNYSIDE ROAD NORTH HOLDING TANK SYSTEM
Project Location(describe,and attach a location map):
56 SUNNYSIDE ROAD NORTH
Brief Description of Proposed Action.
INSTALL REPLACEMENT HOLDING TANK SYSTEM
Name of Applicant or Sponsor: Telephone: 518-932-5701
JOHN ELLIS E-Mail:
Address:
54 SUNNYSIDE ROAD NORTH
City/PO: State: Zip Code:
QUEENSBURY NY 12804
I.Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO YES
administrative rule,or regulation?
If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that I-' ❑
may be affected in the municipality and proceed to Part 2. If no,continue to question 2.
2. Does the proposed action require a permit,approval or funding from any other governmental Agency? NO YES
If Yes,list agency(s)name and permit or approval:
TOQ BOARD OF HEALTH HOLDING TANK VARIANCE El Q
3.a.Total acreage of the site of the proposed action? 0.15 acres
b.Total acreage to be physically disturbed? LESST"^"0I acres
c.Total acreage(project site and any contiguous properties)owned 0.27
or controlled by the applicant or project sponsor? acres
4. Chec land us c rh t occur on,adjoining r the propc.a -action.
rban rural(non-agriculture) ndustrial ;ommercial ✓Residential(suburban)
❑Forest iigricultureAquatic I ether(specify):
'arklan
Page 1 of 4
5. Is the proposed action, NO YES N/A
a.A permitted use under the zoning regulations? 1'�
b.Consistent with the adopted comprehensive plan? ✓
6. Is the proposed action consistent with the predominant character of the existing built or natural NO YES
landscape? ❑ t ,1
7. Is the site of the proposed action located in,or does it adjoin,a state listed Critical Environmental Area? NO YES
If Yes,identify: LAKE SUNNYSIDE
El El
8. a.Will the proposed action result in a substantial increase in traffic above present levels? NO YES
b.Are public transportation service(s)available at or near the site of the proposed action?
c.Are any pedestrian accommodations or bicycle routes available on or near site of the proposed action? �/ n
9.Does the proposed action meet or exceed the state energy code requirements? NO YES
If the proposed action will exceed requirements,describe design features and technologies:
El
10. Will the proposed action connect to an existing public/private water supply? NO YES
If Yes,does the existing system have capacity to provide service? 0 NO 0 YES
If No,describe method for providing potable water: 111EXISTING WELL
11.Will the proposed action connect to existing wastewater utilities? NO YES
If Yes,does the existing system have capacity to provide service? 0 NO 0 YES
If No,describe method for providing wastewater treatment:
REPLACEMENT HOLDING TANK SYSTEM I�/
12. a.Does the site contain a structure that is listed on either the State or National Register of Historic NO YES
Places?
b.Is the proposed action located in an archeological sensitive area?
13.a.Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO YES
wetlands or other waterbodies regulated by a federal,state or local agency? /
b.Would the proposed action physically alter,or encroach into,any existing wetland or waterbody? v
If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres:
14,14ntify the typical habitat types that occur on,or are likely to be found on the project site. Check all that apply:
✓ Shoreline 0 Forest 0 Agricultural/grasslands 0 Early mid-successional
0 Wetland 0 Urban QSuburban
15.Does the site of the proposed action contain any species of animal,or associated habitats,listed NO YES
by the State or Federal government as threatened or endangered?
rj'j n
16.Is the project site located in the 100 year flood plain? NO I YES
✓ I El
17.Will the proposed action create storm water discharge,either from point or non-point sources? NO YES
If Yes, El Ela.Will storm water discharges flow to adjacent properties? 0 NO 0 YES
b.Will storm water discharges be directed to established conveyance systems(runoff and storm drains)?
If Yes,briefly describe: 0 NO 0 YES [] n
Page 2 of 4
18.Does the proposed action include construction or other activities that result in the impoundment of NO YES
water or other liquids(e.g.retention pond,waste lagoon,dam)?
If Yes,explain purpose and size: 1500 GAL.WASTEWATER HOLDING TANK SYSTEM E1
19.Has the site of the proposed action or an adjoining property been the location of an active or closed NO YES
solid waste management facility?
If Yes,describe: ❑
20.Has the site of the proposed action or an adjoining property been the subject of remediation(ongoing or NO YES
completed)for hazardous waste?
If Yes,describe:
I AFFIRM THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY
KNOWLEDGE
THOMAS CENTER,PE HUTCHINS ENGINEERING 3/27/18
Applicant/sponsor name: Date:
Signature:
Part 2-Impact Assessment. The Lead Agency is responsible for the completion of Part 2. Answer all of the following
questions in Part 2 using the information contained in Part 1 and other materials submitted by the project sponsor or
otherwise available to the reviewer. When answering the questions the reviewer should be guided by the concept"Have my
responses been reasonable considering the scale and context of the proposed action?"
No,or Moderate
small to large
impact impact
may may
occur occur
1. Will the proposed action create a material conflict with an adopted land use plan or zoning
regulations?
2. Will the proposed action result in a change in the use or intensity of use of land?
3. Will the proposed action impair the character or quality of the existing community?
4. Will the proposed action have an impact on the environmental characteristics that caused the
establishment of a Critical Environmental Area(CEA)?
5. Will the proposed action result in an adverse change in the existing level of traffic or
affect existing infrastructure for mass transit,biking or walkway?
6. Will the proposed action cause an increase in the use of energy and it fails to incorporate
reasonably available energy conservation or renewable energy opportunities?
7. Will the proposed action impact existing:
a.public/private water supplies?
b.public/private wastewater treatment utilities?
8. Will the proposed action impair the character or quality of important historic,archaeological,
architectural or aesthetic resources?
9. Will the proposed action result in an adverse change to natural resources(e.g.,wetlands,
waterbodies,groundwater,air quality,flora and fauna)?
Page 3 of 4
No,or Moderate
small to large
impact impact
may may
occur occur
10. Will the proposed action result in an increase in the potential for erosion,flooding or drainage
problems?
11. Will the proposed action create a hazard to environmental resources or human health?
Part 3-Determination of significance. The Lead Agency is responsible for the completion of Part 3. For every
question in Part 2 that was answered"moderate to large impact may occur",or if there is a need to explain why a particular
element of the proposed action may or will not result in a significant adverse environmental impact,please complete Part 3.
Part 3 should,in sufficient detail,identify the impact,including any measures or design elements that have been included by
the project sponsor to avoid or reduce impacts. Part 3 should also explain how the lead agency determined that the impact
may or will not be significant.Each potential impact should be assessed considering its setting,probability of occurring,
duration,irreversibility,geographic scope and magnitude. Also consider the potential for short-term,long-term and
cumulative impacts.
o Cheek this box if you have determined,based on the information and analysis above,and any supporting documentation,
that the proposed action may result in one or more potentially large or significant adverse impacts and an
environmental impact statement is required.
o Check this box if you have determined,based on the information and analysis above,and any supporting documentation,
that the proposed action will not result in any significant adverse environmental impacts.
Name of Lead Agency Date
+T
Print or Type Name of Responsible Officer in Lead Agency Title of Responsible Officer
Signature of Responsible Officer in Lead Agency Signature of Preparer(if different from Responsible Officer)
Page 4 of 4
Signature Page
This page includes the Authorization to Act as Agent Form, engineering Fee Disclosure, Authorization for Site Visits, Other
permit responsibilities and agreement to provide documentation required.
Complete the following if the OWNER is using an Agent:
Owner's Name: JOHN ELLIS
Designates: HUTCHINS ENGINEERING as agent regarding Septic Variance for
Tax Map ID;
279.17-2-35
OWNER'S SIGNATURE: Date:
r 3/27/18
Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design, storm
drainage, etc.as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the
applicant.
Authorization for Site Visits: By signing this page and submitting the application materials attached, herein, the Owner,
Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and
Town Engineer to enter the subject properties for the purpose of reviewing the application submitted.
Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of
Health. It is the applicant's responsibility to obtain any additional permits.
Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape
record the proceedings of the meetings resulting from application, and that minutes transcribed from those tapes constitute the
official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the
designated stenographer,the handwritten minutes shall be deemed the official record.
✓I, the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission
requirements and completed the checklist.
PRINT NAME OF OWNER: JOHN ELLIS
SIGNATURE OF OWNER:
C /.
DATE: 3/ 7/
PRINT NAME OF AGENT: HUTCHINS ENGINEERING
SIGNATURE OF AGENT:
DATE: 3/27/18
Town of Queensbury Building&Codes Septic Variance Application 518-761-8256
DEED REFERENCE:
1) BARBARA DENIG AS ADMINISTRATRIX OF THE ESTATE OF FRANK ANTHONY
COLOTTI JR., TO JOHN ELLI% FILED IN THE OFFICE OF THE WARREN COUNTY
CLERK IL WWW AMA AT Pe(F aG- neTFn CFPnWRFR 29. 2006.
MAI
1) 'MAF
DATEC
NOT
1) BASE
2) NORTF
3) TOGET
THE F
4) SUBJE
5) ISITHi
ANY !
6) SUBJE
REGAF
7) UNAU1
SURVE
NEW
8) ONLY
TRUE
9) CERTIF
IN AC
AOOP'
THE C
PREP)
INSTIT
NOT T
10) THE I
KNOW
ENCRC
NOT C
WASTEWATER SYSTEM DESIGN
2 -BEDROOM DESIGN
WATER SAVING FIXTURES - REPLACE EXIST. FIXTURES AS NEEDED
(1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS)
DESIGN FLOW - 110 GPD/BEDROOM
SYSTEM DESIGN FLOW - 220 GPD
HOLDING TANK DESIGN
,� s35•24i 2s„ E
b
NYSDOH SIZING - 5 -DAYS DESIGN FLOW - 1100 GALS
Y
f
f
TOWN OF QUEENSBURY HOLDING TANK VOLUME REQUIRED:4a
.4 f'J
\ cL
-§136-11a
3000 GAL B. (2)
' 01, € t t G'
LAKE
INSTALL (2) 1500 GAL POLYPROPYLENE TANKS IN SERIES
�
PROPERTY LINE
s r q5V x
6UNNYSIDE
3000 GAL TOTAL TO BE PROVIDED
L. 736 P. 260 �
�J�� p
33'± ALONG LAKE
POTABLE WATER SUPPLY IS EXISTING ON-SITE WELL
10'
tJs
50'
10'
f
- MAINTAIN 50' MINIMUM SETBACK TO HOLDING TANKS
� hwrp�'m:'°°T
rr
dock
- RELAY TO $E INSTALLED ON WATER PUMP CIRCUIT TO SHUT DOWN
SYSTEM MATERIAL SPECIFICATIONS
G{Ft
$ l
-
".. �� �allxY. R :.� . �f�$i e3 �I f.Qf, •:
HOUSE SEWER PIPE
WATER SUPPLY TO HOUSE WHEN ACTIVATED BY WARNING/SHUT
�� tt
4 "
fi�don F91
°hw;.:..F"<,
DOWN ALARM ON PANEL
PIPING TO BE 4” SDR -35 OR SCH-40 PVC. INSTALL WITH 1/4" PER FOOT
Y .,v
ohw
SITE LOCATION LOCATION MAP
To HOLDING TANK ALARM NOTES
ALARM PANEL CONTROLS SHALL BE SJE RHOMBUS TANK ALERT DUO
HOLDING TANK CONNECTOR PIPE
ALARM SYSTEM OR EQUIVALENT, AND PROVIDE THE FOLLOWING
IRF
t1 �j
MONITORING AND CONTROL FUNCTIONS:
G
GRAPHIC SCALE
WHEN LEVEL OF TANK REACHES 509 CAPACITY, ALARM WILL
INDICATE "TANK HIGH LEVEL" WITH A YELLOW LIGHT ON ALARM
PANEL.
WHEN LEVEL OF TANK REACHES 959 CAPACITY, AUDIBLE ALARM
WILL SOUND AND RED LIGHT WILL FLASH, INDICATING "TANK
SHUTOFF LEVEL".
ELECTRICAL INTERLOCK SHALL BE INSTALLED TO DISABLE WATER
SUPPLY UPON REACHING "TANK SHUTOFF LEVEL".
SYSTEM WILL RESET AFTER HOLDING TANKS ARE PUMPED DOWN
TO BELOW THE ACTUATION LEVEL OF "TANK HIGH LEVEL"
ALARM.
AN ELECTRICAL INSPECTION BY A CERTIFIED ELECTRICAL INSPECTION
AGENCY IS REQUIRED AFTER INSTALLATION. ELECTRICAL INSPECTION
SEAL IS TO BE AFFIXED TO ALARM CONTROL PANEL.
VARIANCE SUMMARY
THE FOLLOtMNG RELIEF IS REQUESTED FROM THE TOWN OF
QUEENSBURY CHAPTER 136 SEWERS AND SEWAGE DISPOSAL:
HOLDING TANK INSTALLATION - §136-11 A.
- INSTALL TWO 1500 GALLON WASTEWATER HOLDING TANKS
HORIZONTAL SEPARATION DISTANCES - §136-9 D.
- BUILDING SETBACK - 10' REQUIRED,
6' PROPOSED - 4' OF RELIEF REQUESTED
- NEIGHBORING WELL SETBACK - 50' REQUIRED,
45' PROPOSED - 5' OF RELIEF REQUESTED
- EXISTING WELL SETBACK 50' REQUIRED,
13' PROPOSED - 37' OF RELIEF REQUESTED
9• `
,� s35•24i 2s„ E
W RSTEW ATER SYSTEM SETBACK SCHEDULE
.Bends n/f �
.4 f'J
LAKE
Fung Mei Ling
& John E. Ellis
/ti° �� r
,
PROPERTY LINE
WELLS
6UNNYSIDE
HOUSE
L. 736 P. 260 �
�J�� p
33'± ALONG LAKE
HOLDINGTANK
10'
S0'
50'
10'
N49'1733 W IPF f�
rr
dock
SYSTEM MATERIAL SPECIFICATIONS
HOUSE SEWER PIPE
PIPING TO BE 4” SDR -35 OR SCH-40 PVC. INSTALL WITH 1/4" PER FOOT
MINIMUM SLOPE.
HOLDING TANK CONNECTOR PIPE
IRF
t1 �j
PIPING TO BE 4" SDR -35 OR SCH-40 PVC. INSTALL LEVEL
G
GRAPHIC SCALE
j�
LA
BACKFILL MATERIAL
BACKFILL TO BE GRANULAR SAND BACKFILL MATERIAL WITH NO PARTICLES
20 0 10 20 40 80
GREATER THAN 1".
( IN FEET)
APPROXIMATE
POLYETHYLENE EXTENSION
POLYETHYLENE EXTENSION
FINISH GRADE
TO GRADE WITH TAMPER
TO GRADE WITH TAMPER
1 inch = 20 ft.
RESISTANT ACCESS COVER
RESISTANT ACCESS COVER
1500 GALLON
12"t
4" PVC SDR -35
INJECTION MOLDED
12"f
CONNECTOR PIPE
POLYPROPYLENE SEPTIC TANK
4" SDR -35
PVCINSTALLED
LEVEL
INSTALLED AS HOLDING TANK
3
INLETLIQUID LEVEL
SEALED WATERTIGHT
TAX MAP # 279.17-2-35
—
MIN. SLOPE
r
I
LIQUID LEVEL
1/4" PER FOOT
16"
INSTALL FLOAT SWITCHES
TO OPERATE ALARM PANEL
ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED
PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.
509 CAPACITY
AT INDICATED LEVELS
WATERTIGHT SLEEVE
(1500 GAL)
959 CAPACITY
AND SEAL (TIP.)
WARNING LEVEL
(4275 GAL)
ALARM LIGHT ON
ALARM/SHUT DOWN
1500 GALLON
ALARM ON
INJECTION MOLDED
_..
POLYMER SEPTIC TANK
<:'., <
-
A
INSTALLED SHO HOLDING G TANK
.4
Y
FN
7EA GRAVEL
6"1 PEA GRAVEL
0
ISSUED FOR WASTEWATER VARIANCE
3/2;
HOLDING TANKS IN SERIES DETAIL
No.
Revisions
Da
NTS
HOLDING TANK NOTES
HOLDING TANK PLAN
ALL UNITS SHALL COMPLY WITH THE
REQUIREMENTS OF THE NEW YORK RUBBER GASKETS SHALL BE INSTALLED IN ALL INLETS AND OUTLETS.
prepared for
D,FSafely,
F INJECTION MOLDED
POLYPROPYLENSTATE E�EAS MANUFACTURED NT OF HEALTH "BY NFILTRATORD SHALL BE OWATER TECHNOLOGIES, TANKS ARE NOT APPROPRIATE TO BE INSTALLED IN
TRAFFIC AREASg
John Ellis
�/
New �rk
MODEL IM -1530 OR EQUIVALENT.
®I -
Dig
TANKS TO BE BACKFILLED KITH CLEAN SAND
FILL; NATIVE COBBLY,
56 Sunnyside Rodd North
IM Can Before You
ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BOULDERY SOILS ARE NOT ACCEPTABLE AS BACKFILL MATERIAL.
® wait The Required Time
IM Confirm Utility Response
BASE. WHERE EXIS77NG SOIL CONDITIONS ARE UNSUITABLE, A 12 MIN.
Town of Queensbury, Warren County, New York
Respect The Marks
COURSE OF CRUSHED STONE SHALL BE
PLACED AS NECESSARY TO ACHIEVE ALL SEAMS, PENETRATIONS, & ACCESS COVERS MUST BE MAINTAINED
Drawn: TRC
Checke : GTH
Scaler 1"=10'
Date: 2/5/18
IM Dig with Care
A STABLE BASE.
WATER71GHT BY INSTALLER. FIELD COAT ADDITIONAL
PENETRATIONS AS
800•962.7962
NECESSARY WITH WATERTIGHT SEALANT.
169 Haviland Road
www.digsafelynewyork.com
Queensbury, NY 12804
291248-01-
(518) 745-0307 Phone
�iUtCi11t1S Engineering