Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-000065-2017
TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-000065-2017 Date Issued: Friday, September 14, 2018 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-000065-2017 Tax Map Number: Location: Owner: 296.15-1-1 148 Sweet RD Morgan Stanhope, David Stanhope Witt Construction, Inc.Applicant: This structure may be occupied as a: Single-Family Dwelling w/ gas FP 3,099 sq. ft. Attached Garage 505 sq. ft. Cross Ref. Z-AV-45-2017; P-SP-52-2017; P-FWW-4-2017 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement W*4 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: RC-000065-2017 Tax Map No: 296.15-1-1 Permission is hereby granted to: Witt Construction,Inc. For property located at: 148 Sweet RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Morgan Stanhope Single Family-New $663,500.00 Owner Address: 127 GRANT AVE Total Value $663,500.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Witt Construction,Inc. 563 North Broadway Saratoga Springs,NY 12866 Plans&Specifications Single-Family Dwelling w/gas FP 3,099 sq.ft. Attached Garage 505 sq.ft. Cross Reff, Z-AV-45-2017;P-SP-52-2017;P-FWW-4-2017 $1,595.55 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,November 9,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queens ore;thepeawtiodate. Dated at the Town o ueens Th vember 9,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement PRINCIPAL STRUCTURE APPLICATION Office use Only D Date: 7 FEB 2 4 2 17 Tax Map 1D _s,?�L, Permit No., 1 - I - I Permit Fee`!_ TOM OF Q"WEE SBURY Zone Historic? _Yes ✓No Ree Fee y,�,� COMMIVE O M NT Subdivision Name Lot# Site Plan# Subdivision# Project Location t`I'a5v'r _LZ _ TOWN BD.RESOLUTION 86-2013: $850 recreation ee fo ew dwelling u it single f f ily,duplexes/two-family,multiple family, apartments,condominiums,townhouses,and/or manufactured&modular homes,but not mobile homes. This is in addition to the permit fee(s). Primary Owner(s) Address Phone/Email Applicant r Address r10 14, � Phone/Email S14 14" Contractor Address Phone/Email Contact Person for Building&Codes Compliance., Phone TYPE OF CONSTRUCTION ,/Check all that apply New Addition Alteration Igo floor sf 21a floor sf Total sf Height Single Family / Two-Family Multi-Family (#of units Townhouse Business Office Retail-Mercantile Factory-Industrial Attached Garage (1, 2, 3, 4+) I 5 JJ Other Town of Queensbury Building&Codes Principal Structure Applicatic 296.15-1-1 RC 65-2017 David & Morgan Stanhope corner of Country Club & Sweet Roads SFD w/ att. garage, 1-gas fp If commercial or industrial please indicate name of business Proposed use of building or addition a Source of Heat(circle one) Gas Oil ro an Solar Other Fireplace: Complete a separate application for Fuel Burning Appliances&Chimneys (lam Are there structures not shown on plot plan? Are there easements on the property? Site Information: a. Dimensions or acreage of lot y f b. Is this a corner lot? v' Yes No c. Will the grade be changed as a result of construction Yes--V No d. Public water or Private well(circle one) (Mip Private e. Sewer or Private Septic System(circle one) ewer Private Value of all work to be performed(labor or materials) $ DECLARATION. 1. I acknowledge no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If work is not complete by the I year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement / description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations 4. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. 5. I also understand that I /we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Val DATE: J JL4 - I'j SIGNATURE: y, DATE: For office use only Operating Permit Issued: Yes No Occupancy Type Construction Classification Assembly Occupancy Limit Special Conditions Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 SEPTIC DISPOSAL APPLICATION Office Use Only Received DATE: _ �- � - 1-7 Tax Map ID TAX MAP ID: 029 1� - - I Permit No. ZONE: _ w7h Lz Permit Fee APPLICANT PHONE/E-MAIL ADDRESS l INSTALLER/ HONE I E-MAIL BUILDER OWNER ADDRESS CONTACT PERSON FOR BUILDING&CODE COMPLIANCE: i An PHONE/E-MAIL ? �5'x-� -,.jkYy,(DI Y�Sc�YL� GYl. �blrh RESIDENCE INFORMATION Year Built #of bedrooms X gallons per bedroom =total Daily flow 1980 or older Garbage grinder installed Yes No 1981-1991 Spa or Hot Tub installed Yes No 1992-Present PARCEL INFORMATION Topography Flat rolling Steep slope %Slope Soil Nature Sand Loam Clay Other Groundwater At what depth: Bedrock/Impervious material At what depth: Domestic Water Supply Municipal Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch(test to be completed by licensed engineer/architect) ® PROPOSED SYSTEM FOR NEW CONSTRUCTION - a Tank size gallons(min.size 1,000 gallons,add 250 gallons to size for each'glrbage cylinder or spa or hot System Absorption field with#2 stone Total length ft.;Each Trench Seepage Pit with#3 stone How many: ;Size Alternative System Bed or other type: Holding Tank System Total required capacity? Tank size #of tanks Notes: 1)Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency;2)We will no longer allow systems to be covered until such time as an As-Built plan is received&approved. The installed system must match the septic system layout on file-no exceptions. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: R DATE: _ ,.' _J�-U SIGNATURE: DATE: Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Fuel Burning Appliance & Chimney Application Office Use Only Received DATE: 02 1 Tax Map TAx MAP ID: - �{l (� - - Permit 0P 0 ZONE: Permit ee OWNER PHONE/E-MAIL I - ADDRESS INSTALLER/ PHO /E'-MAIL) BUILDER (�s is-) CONTACT PERSON FOR BUILDING&CODE COMPf IANCE: �'(��,� I a �"yb 4,y, � A PHONE/E-MAIL 5t8- SS} �f tl3 n, BUILDING ADDRESS ROOM OF INSTALL: y, ,��j j� y Z, PLANNED INSTALL DATE: FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL NOTE: OUGH-IN& STOVE FINAL INSPECTION ARE FIREPLACE INSERT REQUIRED. FIREPLACE,FACTORY BUILT* NOTE: FIREPLACE,MASONRY MANUFACTURER'S FURNACE(GARAGE ONLY) INSTALLATION MANUAL MUST BE AVAILABLE AT TIME OF INSPECTION *If factory built provide manufacturer name: &,,A, . , , . b ; Model Listed by: (.a . L+ Number: `T&D CHIMNEY INFORMATION Masonry** (check one) BLOCK BRICK STONE Flue TIE STEEL Size in inches Material DOUBLE WALL TRIPLE WALL INSULATED ** If non-masonry provide manufacturer name: -k - y). b ; Model#: DECLARATION: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations,and all conditions that are part of these requirements and also will allow inspector's to enter premises to perform required inspections. I HAVE READ AND AGREE TO THE ABOVE: PRINT NAME: = ;,t, , - i , DATE: SIGNATURE: DATE: y Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 Town of Queensbury Thomas R. Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury,NY 12804 Home: 518-745-0929 Phone: 518-761-8211 Fax: 518-745-4466 David Duell Deputy Highway Superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: ,4 - 0 Applicant Name: Telephone No.: 0411 Address to be Inspected O.c n,n C r- << A- - e_dr Lkn Ir, A (?-Al I 42d Return Address: Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale ( ) Deep Swale ( } Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used(if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( } Rejected Date: Thomas R. Van Ness,Highway Superintendent David Duell,Deputy Highway Superintendent Town of Queensbury Building&Codes Principal Structure Application Revised January 2016 INSPECTION WORKSHEET (006536-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: Inspection Date: Inspector: Case Module: Inspection Status: Inspection Type: RC-000065-2017 09/10/2018 John O'Brien Permit Failed Residential Final Inspection Job Address:Parcel Number:148 Sweet RD Queensbury, NY 12804 296.15-1-1 Contact Type Company Name Name Primary Owner Stanhope, Morgan Granted Permission Witt Construction, Inc.[Witt Construction, Inc.] Contractor Witt Construction, Inc.[Witt Construction, Inc.] Primary Owner Stanhope, David Applicant Witt Construction, Inc.[Witt Construction, Inc.] Checklist Item Passed Comments Sep 10, 2018 Page (13) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments General Comments NO DO NOT ISSUE C/O: until water dept has given approval. AS of 8/30/18, there is no water/sewer/septic hook up. 9/5/18 Final Inspection Not Approved Remaining Items: - Gas and Electric need to be turned on. - Final Electrical Inspection - Submit Blower Door Test Report. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Receive the Town of Queensbury's water and sewer final approval. - Submit Final Survey - Complete all site work. - Complete all exits from porches as discussed. - Firestop Tub Trap - Cap off all pvc pipes thru floor to basement. - Lag all tops of steel columns as discussed. - Repair Foundation Insulation at wall where sewer line exits. - Set spring hinges on garage fire door. - Need to verify hot water and furnace operating - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. -Submit specs on range hood installed. -Provide Address Number on front of home or at mailbox. The numbers need to be a minimum of 4 inches high. 9/10/18 Final Inspection Not Approved Sep 10, 2018 Page (14) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. - Submit specifications for range hood. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Furnace is not starting gas line may need to be bled. - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. - Verify Final Electrical Inspection. - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Install truss ID Placard on electrical meter pan V/FR 4 inch Building Number Address visible from road YES Chimney Height / B Vent / Direct Vent Location YES Chimney Rain Cap Installed YES Fresh Air Intake YES Fresh air supply 3' from grade YES 3" Plumbing Vent through roof minimum 18 inch NO Outside Spigots have Air Gap YES Roof Complete / Exterior Finish Complete YES Platform at all exterior doors YES Handrail 4 or more risers YES Sep 10, 2018 Page (15) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments Guards at stairs,decks,patios 30" + above grade YES Guard at stairwell at 34" or more YES Window guards req:<2' above floor/6' above grade - quick release installed YES Guard at deck, porches 36" or more YES Handrail Termination at Newell Post or Wall YES Interior/Exterior Railings 34 to 38 YES Grade away from foundation 6 with 10 feet NO 6 clearance to sill plate YES Gas Shut-off Exposed & Regulator (18) Above Grade YES HVAC Vent Terminal 10' from Lot Line & Openings YES Dryer Duct Max Length 35', Labeled Over 35'YES Interior privacy/trim/doors/main entrance 36 YES Bathroom / Kitchen Watertight YES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet YES Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs YES Smoke Detectors: Carbon Monoxide NO - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. Smoke Detectors 3' from Kitchens & Baths R314 YES Every level, Every bedroom YES Outside every bedroom area YES Inter Connected NO - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. Battery backup: _____YES Attic Access 22 x 30 minimum YES Attic Access Insulation = Attic R- Value YES Attic Access Gasketed YES Bathroom Fans, if no window YES Sep 10, 2018 Page (16) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments Plumbing fixtures YES Foundation insulation to floor YES Energy Sticker on Elec. Panel:R-Val. & Heating Sys NO Duct work sealed properly YES Intake Openings YES Range Hood 400+ cfm-Fresh Air REQUIRED NO - Submit specifications for range hood. Blower Door Test Certification YES HRV or ERV Installed per Bedroom Requirements NO - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. Emergency egress below grade YES Furnace shut-off w/in 30 ft. or w/in line of site YES Furnace Hot Water Heater operating NO - Furnace is not starting gas line may need to be bled. Relief Valve ,Heat Trap/Water Temp 110 deg or less YES Encl. Stairs Sheetrock Underside minimum ½ Gypsum YES 1/2" Gypsum or House Wall and Gable YES 5/8" Type X with Living Space Above YES 20 Minute Fire Door/Self-Closing Hardware YES Seals on Garage Doors, esp. Wood YES Basement stairs closed rise greater than 4 inches YES Basement Egress: 5s.f. window w/sill or Bilco door YES Garage Floor Pitched YES Fin Elect; Energy Saving Light Bulbs 50 Percent NO - Verify Final Electrical Inspection. Final Survey Plot Plan NO - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. Arc Fault Breaker Habitable Spaces YES Flex Gas Pipe Bonding NO - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. Sep 10, 2018 Page (17) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments Sewer Dept. Inspection Sticker NO - The Town of Queensbury Water & Sewer Department needs to approve project. Site Plan / Variance required NO - Complete all site work. Truss ID Signage Installed at Electrical Meter NO - Install truss ID Placard on electrical meter pan V/FR Sep 10, 2018 Page (18) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments OK to Issue Temporary C/O NO 9/5/18 Final Inspection Not Approved Remaining Items: - Gas and Electric need to be turned on. - Final Electrical Inspection - Submit Blower Door Test Report. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Receive the Town of Queensbury's water and sewer final approval. - Submit Final Survey - Complete all site work. - Complete all exits from porches as discussed. - Firestop Tub Trap - Cap off all pvc pipes thru floor to basement. - Lag all tops of steel columns as discussed. - Repair Foundation Insulation at wall where sewer line exits. - Set spring hinges on garage fire door. - Need to verify hot water and furnace operating - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. -Submit specs on range hood installed. -Provide Address Number on front of home or at mailbox. The numbers need to be a minimum of 4 inches high. 9/10/18 Final Inspection Not Approved - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. - Submit specifications for range hood. Sep 10, 2018 Page (19) INSPECTION WORKSHEET (006536-2018) Checklist Item Passed Comments - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Furnace is not starting gas line may need to be bled. - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. - Verify Final Electrical Inspection. - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Install truss ID Placard on electrical meter pan V/FR OK to Issue C/O NO Sep 10, 2018 Page (20) O'Brien, John (Inspector) INSPECTION WORKSHEET (006591-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: Inspection Date: Inspector: Case Module: Inspection Status: Inspection Type: RC-000065-2017 09/12/2018 John O'Brien Permit Failed Residential Final Inspection Job Address:Parcel Number:148 Sweet RD Queensbury, NY 12804 296.15-1-1 Contact Type Company Name Name Primary Owner Stanhope, David Applicant Witt Construction, Inc.[Witt Construction, Inc.] Granted Permission Witt Construction, Inc.[Witt Construction, Inc.] Primary Owner Stanhope, Morgan Contractor Witt Construction, Inc.[Witt Construction, Inc.] Checklist Item Passed Comments Sep 12, 2018 Page (1) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments General Comments NO DO NOT ISSUE C/O: until water dept has given approval. AS of 8/30/18, there is no water/sewer/septic hook up. 9/5/18 Final Inspection Not Approved Remaining Items: - Gas and Electric need to be turned on. - Final Electrical Inspection - Submit Blower Door Test Report. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Receive the Town of Queensbury's water and sewer final approval. - Submit Final Survey - Complete all site work. - Complete all exits from porches as discussed. - Firestop Tub Trap - Cap off all pvc pipes thru floor to basement. - Lag all tops of steel columns as discussed. - Repair Foundation Insulation at wall where sewer line exits. - Set spring hinges on garage fire door. - Need to verify hot water and furnace operating - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. -Submit specs on range hood installed. -Provide Address Number on front of home or at mailbox. The numbers need to be a minimum of 4 inches high. 9/10/18 Final Inspection Not Approved Sep 12, 2018 Page (2) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. - Submit specifications for range hood. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Furnace is not starting gas line may need to be bled. - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. - Verify Final Electrical Inspection. - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Install truss ID Placard on electrical meter pan V/FR 9/12/18 Final Inspection Not Approved Remaining Items: - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Submit Engineer's Site Certification Letter. 4 inch Building Number Address visible from road YES Chimney Height / B Vent / Direct Vent Location YES Sep 12, 2018 Page (3) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments Chimney Rain Cap Installed YES Fresh Air Intake YES Fresh air supply 3' from grade YES 3" Plumbing Vent through roof minimum 18 inch YES Outside Spigots have Air Gap YES Roof Complete / Exterior Finish Complete YES Platform at all exterior doors YES Handrail 4 or more risers YES Guards at stairs,decks,patios 30" + above grade YES Guard at stairwell at 34" or more YES Window guards req:<2' above floor/6' above grade - quick release installed YES Guard at deck, porches 36" or more YES Handrail Termination at Newell Post or Wall YES Interior/Exterior Railings 34 to 38 YES Grade away from foundation 6 with 10 feet YES 6 clearance to sill plate YES Gas Shut-off Exposed & Regulator (18) Above Grade YES HVAC Vent Terminal 10' from Lot Line & Openings YES Dryer Duct Max Length 35', Labeled Over 35'YES Interior privacy/trim/doors/main entrance 36 YES Bathroom / Kitchen Watertight YES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet YES Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs YES Smoke Detectors: Carbon Monoxide YES - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. Smoke Detectors 3' from Kitchens & Baths R314 YES Every level, Every bedroom YES Outside every bedroom area YES Inter Connected YES - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. Battery backup: _____YES Attic Access 22 x 30 minimum YES Attic Access Insulation = Attic R- Value YES Sep 12, 2018 Page (4) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments Attic Access Gasketed YES Bathroom Fans, if no window YES Plumbing fixtures YES Foundation insulation to floor YES Energy Sticker on Elec. Panel:R-Val. & Heating Sys YES Duct work sealed properly YES Intake Openings YES Range Hood 400+ cfm-Fresh Air REQUIRED YES - Submit specifications for range hood. Blower Door Test Certification YES HRV or ERV Installed per Bedroom Requirements YES - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. Emergency egress below grade YES Furnace shut-off w/in 30 ft. or w/in line of site YES Furnace Hot Water Heater operating YES - Furnace is not starting gas line may need to be bled. Relief Valve ,Heat Trap/Water Temp 110 deg or less YES Encl. Stairs Sheetrock Underside minimum ½ Gypsum YES 1/2" Gypsum or House Wall and Gable YES 5/8" Type X with Living Space Above YES 20 Minute Fire Door/Self-Closing Hardware YES Seals on Garage Doors, esp. Wood YES Basement stairs closed rise greater than 4 inches YES Basement Egress: 5s.f. window w/sill or Bilco door YES Garage Floor Pitched YES Fin Elect; Energy Saving Light Bulbs 50 Percent YES - Verify Final Electrical Inspection. Final Survey Plot Plan NO - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. Arc Fault Breaker Habitable Spaces YES Sep 12, 2018 Page (5) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments Flex Gas Pipe Bonding YES - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. Sewer Dept. Inspection Sticker NO - The Town of Queensbury Water & Sewer Department needs to approve project. Site Plan / Variance required NO - Complete all site work. Truss ID Signage Installed at Electrical Meter YES - Install truss ID Placard on electrical meter pan V/FR Sep 12, 2018 Page (6) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments OK to Issue Temporary C/O NO 9/5/18 Final Inspection Not Approved Remaining Items: - Gas and Electric need to be turned on. - Final Electrical Inspection - Submit Blower Door Test Report. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Receive the Town of Queensbury's water and sewer final approval. - Submit Final Survey - Complete all site work. - Complete all exits from porches as discussed. - Firestop Tub Trap - Cap off all pvc pipes thru floor to basement. - Lag all tops of steel columns as discussed. - Repair Foundation Insulation at wall where sewer line exits. - Set spring hinges on garage fire door. - Need to verify hot water and furnace operating - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. -Submit specs on range hood installed. -Provide Address Number on front of home or at mailbox. The numbers need to be a minimum of 4 inches high. 9/10/18 Final Inspection Not Approved - While testing the Nest smoke alarms and carbon monoxide detectors the one tested sounded but the other alarms were not sounding. - Submit specifications for range hood. Sep 12, 2018 Page (7) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Furnace is not starting gas line may need to be bled. - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. - Verify Final Electrical Inspection. - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Install truss ID Placard on electrical meter pan V/FR 9/12/18 Final Inspection Not Approved Remaining Items: - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Submit Engineer's Site Certification Letter. Sep 12, 2018 Page (8) INSPECTION WORKSHEET (006591-2018) Checklist Item Passed Comments OK to Issue C/O NO 9/12/18 Final Inspection Not Approved Remaining Items: - Final Survey received and needs to be approved by the Town of Queensbury's Planning & Zoning Administrator Craig Brown. - The Town of Queensbury Water & Sewer Department needs to approve project. - Complete all site work. - Submit Engineer's Site Certification Letter. Sep 12, 2018 Page (9) O'Brien, John (Inspector) INSPECTION WORKSHEET (006359-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: Inspection Date: Inspector: Case Module: Inspection Status: Inspection Type: RC-000065-2017 09/06/2018 John O'Brien Permit Failed Residential Final Inspection Job Address:Parcel Number:148 Sweet RD Queensbury, NY 12804 296.15-1-1 Contact Type Company Name Name Contractor Witt Construction, Inc.[Witt Construction, Inc.] Primary Owner Stanhope, David Primary Owner Stanhope, Morgan Granted Permission Witt Construction, Inc.[Witt Construction, Inc.] Applicant Witt Construction, Inc.[Witt Construction, Inc.] Checklist Item Passed Comments Sep 06, 2018 Page (3) INSPECTION WORKSHEET (006359-2018) Checklist Item Passed Comments General Comments NO DO NOT ISSUE C/O: until water dept has given approval. AS of 8/30/18, there is no water/sewer/septic hook up. 9/5/18 Final Inspection Not Approved Remaining Items: - Gas and Electric need to be turned on. - Final Electrical Inspection - Submit Blower Door Test Report. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Receive the Town of Queensbury's water and sewer final approval. - Submit Final Survey - Complete all site work. - Complete all exits from porches as discussed. - Firestop Tub Trap - Cap off all pvc pipes thru floor to basement. - Lag all tops of steel columns as discussed. - Repair Foundation Insulation at wall where sewer line exits. - Set spring hinges on garage fire door. - Need to verify hot water and furnace operating - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. -Submit specs on range hood installed. -Provide Address Number on front of home or at mailbox. The numbers need to be a minimum of 4 inches high. 4 inch Building Number Address visible from road NO Chimney Height / B Vent / Direct Vent Location NO Chimney Rain Cap Installed NO Fresh Air Intake NO Fresh air supply 3' from grade NO 3" Plumbing Vent through roof minimum 18 inch NO Outside Spigots have Air Gap NO Roof Complete / Exterior Finish Complete YES Platform at all exterior doors YES Sep 06, 2018 Page (4) INSPECTION WORKSHEET (006359-2018) Checklist Item Passed Comments Handrail 4 or more risers NO Guards at stairs,decks,patios 30" + above grade NO Guard at stairwell at 34" or more NO Window guards req:<2' above floor/6' above grade - quick release installed YES Guard at deck, porches 36" or more NO Handrail Termination at Newell Post or Wall NO Interior/Exterior Railings 34 to 38 NO Grade away from foundation 6 with 10 feet NO 6 clearance to sill plate NO Gas Shut-off Exposed & Regulator (18) Above Grade NO HVAC Vent Terminal 10' from Lot Line & Openings NO Dryer Duct Max Length 35', Labeled Over 35'NO Interior privacy/trim/doors/main entrance 36 YES Bathroom / Kitchen Watertight YES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet YES Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs YES Smoke Detectors: Carbon Monoxide NO CO in Bedrooms w/Gas NO Smoke Detectors 3' from Kitchens & Baths R314 NO Every level, Every bedroom NO Outside every bedroom area NO Inter Connected NO Battery backup: _____NO Attic Access 22 x 30 minimum YES Attic Access Insulation = Attic R- Value YES Attic Access Gasketed YES Bathroom Fans, if no window YES Plumbing fixtures NO Backflow Preventors where required NO Foundation insulation to floor NO Energy Sticker on Elec. Panel:R-Val. & Heating Sys NO Duct work sealed properly YES Intake Openings NO Range Hood 400+ cfm-Fresh Air REQUIRED NO Sep 06, 2018 Page (5) INSPECTION WORKSHEET (006359-2018) Checklist Item Passed Comments Blower Door Test Certification NO HRV or ERV Installed per Bedroom Requirements NO Emergency egress below grade YES Furnace shut-off w/in 30 ft. or w/in line of site YES Furnace Hot Water Heater operating NO Low water shut-off boiler NO Relief Valve ,Heat Trap/Water Temp 110 deg or less NO Encl. Stairs Sheetrock Underside minimum ½ Gypsum YES 1/2" Gypsum or House Wall and Gable YES 5/8" Type X with Living Space Above YES 20 Minute Fire Door/Self-Closing Hardware NO Seals on Garage Doors, esp. Wood YES Basement stairs closed rise greater than 4 inches YES Basement Egress: 5s.f. window w/sill or Bilco door YES Garage Floor Pitched YES Fin Elect; Energy Saving Light Bulbs 50 Percent NO CSST/other piping in conduit if buried,if required NO Final Survey Plot Plan NO Arc Fault Breaker Habitable Spaces NO Flex Gas Pipe Bonding NO As Built Septic System NO Sewer Dept. Inspection Sticker NO Site Plan / Variance required NO Flood Plain Certification, if required NO Fuel Tanks above flood plain elevation NO Buried Fuel Tanks anchored in flood zone NO Truss ID Signage Installed at Electrical Meter NO Sep 06, 2018 Page (6) INSPECTION WORKSHEET (006359-2018) Checklist Item Passed Comments OK to Issue Temporary C/O NO 9/5/18 Final Inspection Not Approved Remaining Items: - Gas and Electric need to be turned on. - Final Electrical Inspection - Submit Blower Door Test Report. - The specified Panasonic FV-40VQ4 390 CFM Fan for whole house ventilation appears to have not been installed and ducted directly in to the cold air return. - Receive the Town of Queensbury's water and sewer final approval. - Submit Final Survey - Complete all site work. - Complete all exits from porches as discussed. - Firestop Tub Trap - Cap off all pvc pipes thru floor to basement. - Lag all tops of steel columns as discussed. - Repair Foundation Insulation at wall where sewer line exits. - Set spring hinges on garage fire door. - Need to verify hot water and furnace operating - Provide specifications on black stainless steel gas piping for gas supply. Need to verify if it is an approved bonded piping. -Submit specs on range hood installed. -Provide Address Number on front of home or at mailbox. The numbers need to be a minimum of 4 inches high. OK to Issue C/O NO Sep 06, 2018 Page (7) O'Brien, John (Inspector) INSPECTION WORKSHEET (BINS-001361-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000065-2017Case Module:Permit Inspection Date:02/27/2018Inspection Status:Partial Pass Inspector:John O'BrienInspection Type:Building Framing Job Address:148 Sweet RDParcel Number:296.15-1-1 Queensbury, NY 12804 Contact TypeCompany NameName Primary OwnerStanhope, Morgan Primary OwnerStanhope, David ContractorWitt Construction, Inc., Granted PermissionWitt Construction, Inc., ApplicantWitt Construction, Inc., Checklist ItemPassedComments Building Inspector NotesNO2/27/18 Ice and Water Shield Partial Approval -Main Roof FramingNO Attic Access 22 x 30 minimumNO Jack Studs HeadersNO Continuous Header for Garage Doors with StrapingNO Truss Specification ProvidedNO Bracing BridgingNO Hurricane Clips/Uplift Screws/Nail Holes FilledNO Air Seal all Plates and SillsNO Air Seal All Registers at FloorNO Air Sealing all Joints Before InsulationNO Joist hangersNO Jack Posts Main BeamsNO Exterior sheeting nailed properlyNO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing WallsNO Metal Strapping for Notches Top PlateNO Draft stopping 1,000 sq. ft. floor trussesNO Anchor Bolts 6 ft. or less on centerNO Ice and water shield 24 inches from wallYES2/27/18 Ice and Water Shield Partial Approval -Main Roof Soffits-Insulation BaffelNO Windows Habitable Space BedroomsNO 24 in. (H)NO 20 in. (W)NO 5.7 sf above below gradeNO 5.0 sf gradeNO Design Professional Sign-off, if requiredNO O'Brien, John (Inspector) Feb 27, 2018Page (3) New York State Department of State jORK Bui[din Standards Division of Building Standards ATE OF g and Codes OPPORTUNITY_ and Codes One Commerce Plaza 99 Washington Avenue,Suite 1160 Albany,NY 12231-0001 (518)474-4073 Fax: (518)486-4487 www.dos.ny.gov TB-1003-RCNYS TECHNICAL BULLETIN Lg u1 SEP 1 2016 Code Effective Date: October 3, 2016 TOWN OF QUBENS�BURY BUILDING & CODES Source Document: 19NYCRR 1240 -Energy Code of New York State-2016(ECNYS) 19NYCRR 1220-Residential Code of New York State-2016(RCNYS) Topic Section(s)R403.6(ECNYS), (1103.6-RCNYS)-Mechanical Ventilation (Mandatory) Section M1507-Whole House Mechanical Ventilation (RCNYS) This document is to clarify the issue of the whole house mechanical ventilation as required by the 2016 Energy Code of New York State and Also the 2016 Uniform Code of New York State(Residential Code).SJse 2 15 International Energy Conservation Code (iECC)requires whole house ventilat'ol n systems to be installed in new ham= esi n arameters for Whole House Me h ni 2015 International Residential Code(IRC), Section M1507, and Mechanical Ventilation. TheiRC requires a whole house mechanical ventilation system to exhaust excessive moisture and to provide adequate fresh air for building occupants. The intake of outdoor air is a requirement of the code, See IRC Section M1507.3.3. The code does not specify a specific type of mechanical ventilation system. However, the code requirements for whole house ventilation systems requires that the ventilation system be designed to specified parameters (See 2015 IRC M1507.3)to meet the code criteria. Therefore, anmf§tem meeting all requirements of the code(s) may be utilized. For purposes of clarification,the 2016 Supplement to the New York State Energy Conservation Construction Code (August 2016) defines Building System as follows: the term building system means a combination of central or terminal equipment or components or controls, accessories interconnecting means and terminal devices by which energy is transformed so as to perform a specific function, such a heating, ventilation and air conditioning, service water heating or illumination. Page 2 of 2 Technical Bulletin-Ventilation I,A_I bathroom and kitchen fans are required to be vented to the exterior, see IRC Section M1501. Bathroom and kitchen fans_are_separate components of mandatory ventilation, serving to remove excessive moisture and "-- contaminants_These two exhaust fan locations, are required in addition to whole house ventilation systems, r but ysecve as a component of the who a ouse ventilation systemsJn a typicai ventilation • , continuous run fans(s) or intermittent run fans(s) may be used as part of the system., however, the introduction of outside air is specifically required by the code (see 2015 International Residential Code, (IRC) Section M1507.3.3). Required supplied airflow rates of outdoor air are found in the IRC Table M1507.3.3 (1). The code is silent on the method of supply of outdoor air, therefore any quantifiable method to provide outdoor air may be utilized. John R Addario, PE, Director Division of Building Standards and Codes t-•' 17.Is Mechanical whole house ventilation a requirement of the 2015 IRC?What about Energy Recovery,or Heat recovery?Ventilation systems? Back to Top An Energy Recovery,or Heat Recovery Ventilation system is not required by code. However,the 2015 IECC does require whole house ventilation systems to be installed in new residential structures built to the 2015 IRC.The design parameters for the system are contained in the 2015 IRC,Section M1507,Mechanical Ventilation.This allows for the whole-house ventilation system to consist of one or more a combination of su ip y ors exhaust),and associated ducts and controls , ough the code allows for supply of exhaust fans to serve as a ventilation systein.outdoor air intake must be a considerr tion of the stem.A"Whole House Mechanical Ventilation System"is defined in the Code as:"An exhaust system,supply system,or combination thereof that is designed to mechanically exchange indoor air with outdoor air when operating continuously or through a programmed intermittent schedule to satisfy the whole house ventilation rates."Questions have come up concerning the use of building infiltration air solely for supply air in the building ventilation system,or in practice,the use of exhaust only fans as a system of providing required mechanical ventilation.The code is silent on the method of supply of outdoor air,therefore any quantifiable method to provide the required gpanti�t r_of outdoor air may be utilized.In other words (the use of building infiltration air only,as the source of make-up air must be proven by calculations,or by testing. 201E ICC Mechanical Ventilation Requirements:Dwelling Units in Buildings of Group R-2,R-3,and R-4 Occupancy to 3 Stories 440. 40° 00 Air Leakage • Dwelling units shall be tested with a blower door test and have an air leakage s3 ACHSO in climate zones 3-8 per IECC R402.4.1.2 •Required•all bathrooms sha ave exhaust ventilation(1BC 12035.2.1).Toilet rooms shall have exhaust ventilation where the ancleaka rate in a dwelling Bathroom __In, Lt ie<s e_CHSn when tested with a blower door Mgr.! .2 and 403.3.2.3;IECC R402.4.1.2).Otherwise,toilet rooms shall be naturally or mechanically and Toilet ventilated(IMC 401.2). • Ra t Sn cfn�f.t ittent or a 20 cfm continuous IMC 403.3.2.3 - Exhaust •Jawiradiatment directly to the exterior(IMC 501.3).Sizing shall be in accordance with ACCA Manual D,appliance manufacturer's installation instructions, or other approved methods(IMC 603 2).Materials and any insulation shall be compliant with IMC 603. • Required:kitchen exhaust ventilation required where dwelling unit air infiltration is<5 ACH50 when tested with a blower door(IMC 401.2 and 403.3.2.3;IECC R402.4.1.2).Otherwise,kitchens shall be naturally or mechanically ventilated(IMC 401.2). • Rate:where provided,a 100 cfm intermittent or a 25 cfm continuous(IMC 403.3.2.3) Kitchen • Ducting:For dwelling units<5 ACH50,listed and labeled recirculating range hoods are permitted where mechanical exhaust(e.g.,exhaust fan at the ceiling or Exhaust through the wall)is otherwise provided(IMC 501.3).For dwelling units>5 ACH50,listed and labeled ductless range hoods are permitted where mechanical exhaust or natural ventilation is otherwise provided(IMC 501.3).Sizing shall be in accordance with ACCA Manual D,appliance manufacturer's installation instructions,or other approved methods(IMC 603.2).Materials and any insulation shall be compliant with IMC 603 and SOS.Common exhaust for kitchens is permitted under the conditions of IMC 505.3. •Definitions: o AIR,MAKEUP.Any combination of outdoor and transfer air intended to replace exhaust air and exfiltration(IMC). Makeup Air o AIR,OUTDOOR.Ambient air that enters a building through a ventilation system,through intentional openings for natural ventilation,or by infiltration(IMC). (MUA) Implication:infiltration can be used to contribute to makeup air requirements. • Required:kitchen exhaust systems capable of exhausting in excess of 400 cfm require MUA at a rate equal to exhaust air rate.MUA systems shall have at"a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system"(IMC 505.2). • Required:for dwelling units with air akage s 5 ACH50 as confirmed with blower door test IMC 401.2j •System Types:exhaust,supply,or combination.May be a I . exhau SyS em or OA duct connected to the return trunk of central air handling system with Outdoor Air controls)hat ensure minimum run time IMC 403. -. . (OA •Corridors:corridors exterior to dwelling units shall not serve as supply,return,exhaust,relief,or ventilation air ducts(IMC 601.2,IBC 10205) • Rate:Continuous rate or intermittent rate according to IMC 403.3.2.1.•ICC has issued an erratum to this section that reduces the required flow rate. •Verification:Mechanical rough-in inspection to verify compliance of whole-house ventilation and installed HVAC equipment type and size(IECC R104.2.4) Fans used for OA/whole-house mechanical ventilation shall meet the following minimum efficacy requirements by location(N1103.6.1(R403.6.1)): • Bath or utility room:1.4 cfm/W if<90 cfm and 2.8 cfm/W a 90 cfm;(Note:for comparison purposes,the latest ENERGY STAR ventilation fans requirements Fan Efficacy are . c mif 0 and 3.5 cfm/W if a 90 cfm and s 200 cfm) • Range hood and in-line fans:2.8 cfm/W •Central fan integrated:"Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor." Loudness • No requirements.However,s 1 sone is recommended for continuous duty ventilation fans. 2 www.newPortoartnersHc.com RC_- ©% is • — 7Es ICC Most Widely Accepted and Trusted EVALUATION SERVICE '.. Innovation ICC -ES �� RESEARCH LABS Report PMG-1155 Reissued 01/2018 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org This report is subject to renewal 01/2019 C E vy . , !. h1 T TOWN OF QUELrN.� w 1F``y BUILDING & ;� ,ID EVALUATION SUBJECT: GASTITE® FLASHSHIELD TM METALLICALLY SHIELDED CORRUGATED STAINLESS STEEL TUBING DIVISION: 23 00 00—HEATING, VENTILATING AND AIR CONDITIONING SECTION: 23 11 00—FACILITY FUEL PIPING Report Holder: TITEFLEX CORPORATION GASTITE DIVISION 1116 VAUGHN PARKWAY PORTLAND,TN 37148 Look for the ICC-ES marks of Conformity! CC CC c� pivlG ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes s c not specifically addressed.nor are they to be construed as an endorsement of the subject of the ANSI �� PREFERRED �� report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express ACCREDITED Riau. EDUCATION a11 or implied,as to any finding or other matter in this report,or as to any product covered by the report. PROVIDER EMI INTERATIONAL Copyright C 2018 ICC Evaluation Service,LLC.All rights reserved. u,, � , CODE OUNCIL 0000 CODE COUNCIL` EsEVACUATION SERVICE ,7oy�t;,� Most Widely Accepted and Trusted LILICC-ES PMG Product Certificate PMG-1155 rAts/ Effective Date:January 2018 ` °" This listing is subject to re-examination in one year. www.icc-es-pmq.orq I (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council' CSI: DIVISION: 23 00 00—HEATING,VENTILATING AND AIR CONDITIONING Section: 23 11 00—Facility Fuel Piping Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier's stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier's quality system. Product: Gastite®FlashShieldT'" Metallically Shielded Corrugated Stainless Steel Tubing Listee: Titeflex Corporation Gastite Division 1116 Vaughn Parkway Portland,Tennessee 37148 www.qastite.com Compliance with the following codes: 2018, 2015, 2012 and 2009 International Fuel Gas Code® IFGC) 2018,2015,2012 and 2009International Mechanical Code (IMC) 2018,2015, 2012 and 2009 International Residential Code®(IRC) 2015,2012 and 2009 Uniform Plumbing Code® UPC)* 2015, 2012 and 2009 Uniform Mechanical Code (UMC)* "Copyrighted publications of the International Association of Plumbing and Mechanical Officials. Compliance with the following standards: ANSI LC 1/CSA 6.26-2016, Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) NFPA 54-2015, National Fuel Gas Code ICC-ES LC1027-2016, PMG Listing Criteria for A Protective Jacketed, Corrugated Stainless Steel Tubing (A Minimum 36 Coulomb Charge Transfer) ICC-ES PMG-1019, Gastite Flexible Gas Piping System Identification: Tubing: Each 2 feet (610 mm) of tube bears the Gastite® FlashShieldTM name, part number, rated pressure[25 psi (172 kPa)], equivalent hydraulic diameter(EHD), the words"Fuel Gas,"and the ICC- ES PMG listing mark. Components: Fittings, termination outlets and distribution manifolds are stamped with the Titeflex logo, the part numbers and the date stamp. Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this listing,or as to any product covered by the listing a� COME CONNr Copyright©2018 ICC Evaluation Service,LLC.All rights reserved. Page 1 of 4 PMG-1155 I Most Widely Accepted and Trusted Page 2 of 4 Installation: General: Installation must be in accordance with the Gastite® FlashShieldTM Installation Instructions, IFGC Section 404, IRC Section 2415, UMC Section 1309 and UPC Section 1211, as applicable. The system installation consists of CSST distribution lines installed between the point of delivery and fuel gas appliances. The use and system installation must be in accordance with ICC-ES PMG-1019. Plenum Installation: When tested in accordance with ASTM E 84, Gastite® FlashShieldTM satisfies the plenum installation requirement, with a flame spread index of less than 25 and a smoke development index of less than 50. Electrical Bonding: The Gastite® FlashShieldTM Metallically Shielded Corrugated Stainless Steel Tubing (CSST) System is electrically continuous and is considered to be bonded where it is connected to appliances that are connected to the equipment grounding conductor of the circuit supplying that appliance. Additional bonding prescribed by IFGC Section 310.1.1 and IRC Section G2411.1.1 is not required for Gastite®FlashShieldTM Metallically Shielded CSST when it is installed in accordance with this listing. Models: The Gastite® FlashShieldTM' Metallically Shielded CSST System consists of five parts: (1) a black polymer exterior jacket; (2) metal shield to conduct the stray current; (3) a black polymer interior jacket(4) corrugated stainless steel tubing which is recognized in PMG-1019 as conforming to ANSI LC-1;and(5)mechanical fittings designed for use only with the Gastite®FlashShieldn' CSST. Mechanical fittings utilize a metal-to-metal seal, and include mechanical fittings, distribution manifolds, shutoff valves, termination outlet devices, pressure regulators, tee assemblies and protection devices. Protective metal shield in the multi-layer product must be electronically engaged with each fitting. TABLE—PART NUMBERS: GASTITE®FLASHSHIELDT"TUBING AND FITTINGS 'iBING SIZE PART NUMBER DESCRIPTION (Inch) 112 FS-8 1/2'FlashShieldT"CSST 3/4 FS-11 3/4!FlashShieldTm CSST 1 FS-16 1"FlashShieldT"'CSST 11/4 FS-20 11/4"FlashShieldTM CSST 11/2 FS-24 11/2'FlashShieldT'"'CSST 2 FS-32 2'FlashShieldTM CSST 1/2 FSFTG-8 1/2'FlashShield Straight Fitting-1/2-NPT 3/4 FSFTG-11 3/4"FlashShield " Straight Fitting-3/4'NPT 1 FSFTG-16 1"FlashShieldT"' Straight Fitting--1"NPT 11/4 FSFTG-20 11/4"FlashShieldTM Straight Fitting-11/4"NPT 1/2 XR3FTG-8 1/2"XR3 Straight Fitting--'/2"NPT 3/4 XR3FTG-11 3/4"XR3 Straight Fitting--3/4"NPT 1 XR3FTG-16 1"XR3 Straight Fitting--1"NPT 11/4 XR3FTG-20 11/4"XR3 Straight Fitting-11/4"NPT 11/2 XR3FTG-20 11/4"XR3 Straight Fitting-11/2"NPT 2 XR3FTG-16 2"XR3 Straight Fitting--1" NPT //2 FSFTG-FM-8 1/2"FlashShieldTM Straight Fitting--1/2" Female NPT 3/4 FSFTGFM-11-8 3/4"FlashShieldTM Straight Fitting-1/2"Female NPT 3/4 FSFTGFM-1 I 3/4'FlashShieldTM Straight Fitting--3/4"Female NPT 1/2 XR3FTG-FM-8 1/2"XR3 Straight Fitting--1/2"Female NPT 3/4 XR3FTGFM-11-8 3/4"XR3 Straight Fitting--1/2"Female NPT 3/4 XR3FTGFM-11 3/4"XR3 Straight Fitting--3/4"Female NPT 3/4 FSREDFTG-11-08 3/4"FlashShieldTM Straight Reducing Fitting-1/2"NPT PMG-1155 I Most Widely Accepted and Trusted Page 3 of 4 TUBING SIZE PART NUMBER DESCRIPTION (inch) 1 FSREDFTG-16-12 1" FlashShieldT"'Straight Reducing Fitting—3/4'NPT 3/4 XR3REDFTG-11-08 3/4"XR3 Straight Reducing Fitting—1/2'NPT 1 XR3REDFTG-16-12 1"XR3 Straight Reducing Fitting—3/4"NPT 1/2 FSCPL-8 1/2"FlashShieldTM Coupling 3/4 FSCPL-11 3/4"FlashShieldTM Coupling 1 FSCPL-16 1"FlashShieldT""Coupling 11/4 FSCPL-20 11/4"FlashShieldTM Coupling Assembly 1/2 XR3CPL-8 1/2"XR3 Coupling 3/4 XR3CPL-11 3/4"XR3 Coupling 1 XR3CPL-16 1"XR3 Coupling 11/4 XR3CPL-20 11/4"XR3 Coupling 11/2 XR3CPL-24 11/2"XR3 Coupling 2 XR3CPL-32 2"XR3 Coupling 1/2 FSTRM-8 1/2"FlashShieldTm Termination Fitting—1/2"NPT 3/4 FSTRM-11 3/4"FlashShieldT""Termination Fitting—3/4"NPT 1 FSTRM-16 1"FlashShieldT""Termination Fitting—1"NPT 11/4 FSTRM-20 11/4"FlashShieldT"" Termination Fitting Assembly 1/2 XR3TRM-8 1/2"XR3 Termination Fitting—1/2"NPT 3/4 XR3TRM-11 3/4"XR3 Termination Fitting—3/4"NPT 1 XR3TRM-16 1"XR3 Termination Fitting—1"NPT 11/4 XR3TRM-20 11/4"XR3 Termination Fitting Assembly—11/4"NPT 11/2 XR3TRM-24 11/2"XR3 Termination Fitting Assembly—11/2"NPT 2 XR3TRM-32 2"XR3 Termination Fitting Assembly—2"NPT 1/2 FST-8 1/2"Run x Y2"Run x'4"Tee Fitting 3/4 FST-11 3/4"Run x%"Run x 3/4"Tee Fitting 1 FST-16 1"Run x 1"Run x 1"Tee Fitting 3/4 FST-11-8-8 3/4"Run x 1/2"Run x 1/2"Tee Fitting 3/4 FST-11-11-8 3/4"Run x 3/4"Run x 1/2"Tee Fitting 1 FST-16-11-8 1"Run x 3/4"Run x 1/2"Tee Fitting 1 FST-16-11-11 1"Run x 3/4"Run x 3/4"Tee Fitting 1 FST-16-16-8 1"Run x 1"Run x 1/2"Tee Fitting 1 FST-16-16-11 1"Run x 1"Run x 3/4"Tee Fitting I/2 XR3T-8 1/2"Run x'/"Run x'/3"XR3 Tee Fitting 3/4 XR3T-11 3/4" Run x 3/4"Run x 3/4"XR3 Tee Fitting 1 XR3T-16 1"Run x 1"Run x 1"XR3 Tee Fitting 3/4 XR3T-11-8-8 3/4"R• un x 1/2"R• un x 1/2"X• R3 Tee Fitting 3 " n3/" 1/3/4 XR3T-11-11-8 /4 R• un x 4 R• un x 2"X• R3 Tee Fitting 1 XR3T-16-11-8 1"Run x 3/4"Run x 1/2"XR3 Tee Fitting 1 XR3T-16-11-11 1"Run x 3/4"Run x 3/4"XR3 Tee Fitting 1 XR3T-16-16-8 1"Run x 1"Run x 1/2"XR3 Tee Fitting 1 XR3T-16-16-11 1"Run x 1"Run x 3/4"XR3 Tee Fitting For SI: 1 inch=25.4 mm. Conditions of listing: • • PMG-1155 I Most Widely Accepted and Trusted Page 4 of 4 1. Gastite® FlashShieldTM has been tested (in accordance with LC1027) and complies with the minimum performance threshold for indirect effects lightning testing. • Indirect Effects 1 Threshold: 10 coulombs minimum utilizing a 10 x 1000 ps current waveform • Indirect Effects 2 Threshold: Component 1 (Return Stroke) Peak Amplitude 30 kA minimum Action Integral 0.055 x 106 A2s, minimum Time Duration s 500 ps Component 2 (Intermediate Current) Maximum Charge Transfer 10 coulombs(± 10%) Average Amplitude 2 kA(±20%) Time Duration 5 5 ms Component 3(Continuing Stroke) Amplitude 200—800 A Charge Transfer 26 coulombs, minimum 2. Electrical Bonding: The FlashShieldT"" Metallically Shielded Corrugated Stainless Steel Tubing System is electrically continuous and is considered to be bonded where it is connected to appliances that are connected to the equipment grounding conductor of the circuit supplying that appliance. 3. The protection is from indirect lightning only and the effect of direct lightning strike is beyond the scope of this listing. 4. The CSST piping system must not be used as a grounding electrode for an electrical system. 5. Additional information and requirements are defined in ICC-ES PMG-1019. 6. Protective metallic shield in the multi-layer product must be electronically engaged with each fitting. 7. The Gastite® FlashShieldn' Metallically Shielded CSST System is manufactured by Titeflex Corporation Inc. in Portland, Tennessee, under a quality control program with annual surveillance inspections by ICC-ES. LC1027-rated Flexible Gas Piping System Specification GAS PIPING Flexible fuel gas piping system to comply with and maintain IAPMO and ICC-ES listings to ICC-ES PMG LC1027 `Listing Criteria for Protective Jacketed Corrugated Stainless Steel Tubing(Minimum 36 Coulomb Charge Transfer)'. Flexible gas piping system also to be listed by CSA to ANSI LC 1/CSA 6.26 standard 'Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing'. MATERIALS Materials to be metallically shielded CSST manufactured from ASTM A240 Type-304 stainless steel with a minimum nominal wall thickness of 0.01". A protective jacket system over the CSST consisting of an electrically insulative polymer cover, a metallic shield layer, and a semi- conductive inner polymer layer. The piping system being UV-Resistant, and achieving ASTM E84 ratings of(25) for flame spread and (50) for smoke density. Mechanical fittings are to be manufactured from ASTM B16 Type-360 brass. Brass fittings include a jacket-lock feature to provide circumferential contact between the fitting assembly and outer polymer layer of the CSST. INSTALLATION The flexible gas piping system shall be installed per the current version of the manufacturer's Design& Installation Guide and local codes. System training is required and provided by the CSST manufacturers and/or its training representatives. Training certification cards will be provided to installers who successfully meet the training requirements. 6/15/17 9/11/2018 VHOOO:PRH18142 Products Settings Tools Admin Help IAC—JOMARCELLA---marcella1123@gmail.com Log Out �r RetailDeck~ VHOOD 42" PRH 18 - Premier Magic Lung® Comparable Models Professional/Standard Wall Mounted (300 cfm) $ Product Search a PRH13142 Customize This Item Print-Friendly View, 42"PRH18-Premier Magic Lung®Professional/Sta d V+/sic 11nttE(3fl0i) I ( dei: PRH18142 11ev ti ' atk a w• 6 r,3, ) � 11 ' i i t� SEP 1 2 2018 I TOWN OF QUEENSBIJRY BUILDING& CODE Features Specifications Colors&Related Items Documents Rebates Finance Competition ` Technical Data Specifications WIDTH: 42" DEPTH: 24" HEIGHT: 18" CFM: • 300 SONES: 5.4 Amps: 2.5 Num.Lights': 3 • ELECTRICAL/MECHANICAL SPECIFICATIONS FOR BLOWER UNIT Model B100 Single Volts 115 Amps+ 2.5 Hz 60 RPM 1550 CFM SP@0.0 300 Equiv.CFM$ 450 CFM SP@O.1" 273 CFM SP@0.2" 245 CFM SP@0.3" 225 Min.Round Duct Size 6"(28 sq.in.) Sones# 5.4 While we do our best to make sure our dimension data is accurate,errors sometimes do occur--in all cases,dimensions should be confirmed by reviewing the manufacturer supplied dimension drawing and/or cut sheet. Report Missing or Inaccurate Product Specifications... You are presently logged in as marcella1123@gmail.com,click here to log out Your use of the Software is governed by these terms and conditions. Copyrights 2006-2018 Appliance Retailing Information Systems U.C. A limited liability company organized under the laws of the state of Arizona.All Rights Reserved.Unauthorized access is prohibited. hops://app.retaildeck.co tem details/item_detaiis.html?key=VENTAHOOD%3APRH18142SS&FW=200562%3a101498 1/2 FUEScheck Software Versiora 4.&,S Compliance Certificate LN of NE 'k Project Stanhope Residence Energy Code: 2015 JECC Locatl= Glen% Falls, New Yak cP Oz cohStniftion Typmtl projea Type; 090ci I Now Construction py Conditioned Floor Afew, 3,971 ftZ gOFEFSSION Glazing Area Olmate,Zomel 6 (1635 HOW I lierrn ..It Oatc Permit Number ,- Construction Site; -teactor; Country CIO Drive, Witt Construction, Inc, Qo0onsbory, NY 12004 -501 North Proodway Satatoqa Spring-S, NY 12006 Cvripfiamce� 14%illetterThain!Cade *Mlayomumn UA: 430 Y@,3r UA- 432 The%Ostkar(;r worst,Them Como-Inde*r0*09 rOW dfUe tO COMP11060 the MOUSe 1A WO OA 400.4 trade lo"rule, it DOES NOT ptoyloa an ealmato,ofemeroy use or Kort relative to a mlriiMurru4mda homa. Enveicipe Assemblies Basement-Unfinish.oM Solid Concrete or Masonry 015 0:0 1510 0,046 41 Wall height: 7,-51 Oepth below grade! 6,61 Int.,ulation depth! 7,51 Pella 250 Slider:Vinyl/Fiberglass FrarnwDouble Pane with Low-E 16 0,270 4 Basement-Stair Areat Solid Concrete or Masonry 133 00 i5,0 0,046 6 Wall helgft 751 Depth below grade: 6,81 Insulation depth! 7,5° Basement-Flnlshed, Solid Concrete or Masonry 67 21t0 010 0,043 3 Wall height; 7.51 Depth below grade: 6,81 Insulation depth: 7.51 Basement 0 Low Grade-Finished: Solid Concrete or Masonry 461 21,0 010 0,052 22 Wall height: 7,51 Depth below grade! 3.51 Insulation depth: 7.5' Pella 250 511der: Vinyl/Fiberglass Frame:Double Pane with Low-E 4S 0,270 12 1st Floor Walls: Wood Frame, 16" o.c. 2,071 2110 010 0,057 100 Pella 250 Awning:Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0,270 2 Pella 250 Case:Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.260 16 Pella 250 DH:Vinyl/Fiberglass Frame:Double Pane with Low-E 85 0.270 23 Pella 250 Fixed:Vinyl/Fiberglass Frame:Double Pane with Low-E 71 0.260 18 Project Title: Stanhope Residence Report date: 04/17/18 Data filename: Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page I of10 Calc.rck a 1;i Al - MEN 8lia X50ransarri;Vlnyi/ iaerglatts r"rarn ,pouti Pane vtrltf MON OW-E y7 d �iJ27� ; ntry Door; Salld 20 tld q 7 Fire poor:%olid 20 OMO 7 Pella Entry moor; Glass 43 01300 13 KitchOn/ileiirg aumOut! NO Ceiling of kssor Truos 23 3810 A100,0 30 k1. Moistor Suite eoa roti3Raised or "riergy pu%.6 $SSsryf✓ $1020 1.w 2nd Floor Walls; Wood�r�in1�, 1$"odcd 079 :1,O 01057 a Pella 250 Awming,,vinywlberglass r f+Watbouble Emla with Low4 S 01270 2 Pella 256 M Vinyl/FJbefgiasS Ffamei0oublo Bane with Low.8 105 01M 50 2nd door Truss oiling; Raised of Onorgy Truoo 11182 4910 0,0 O.MO 24 2nd Floor I'lat CRiii% paiORd of Rnorgy Tru;% 16 WO 0 0 0102.4 0 n.d Floor Cloped Ceilingi AaifioO or Onmrpy.t vu lot 3010 ortaPlla ce Statementt Th.o proposed building 0051 ri desdribed here i ot�4i:9t iii with the l uiiding pian, pa lfic ti ns,grad other calcuiatlons isubmitted with the permit appllcation� The proposed bollding hAS beets d:e�igned to Meet the X00 IACC requirements in RrCt�eck'�arsln . , end to comply with the onandatory require ents92std the >€Inpfctlon lhegklfst, a e T. le±Lk nature _ Date Project Title: Stanhope Residence Report date; 04/17/18 Data filename: ZACurrent Client Proyects\witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 2 of10 Calc.rck R E S C h e--c k S c,f t vva e V em r s 1 o n 4 F 6,9u f 15 t f Inspection Checklist i Energy Code: 2015 IECC Requirerrientz, 0,0% wQre addressed directly In the REScheck�-oftiwaee Text In the "Comrnents/Assumptlonsl" column Is provided by the user In the 05chiack Pequirematits screen, Por each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception Is being claimed, Where compliance Is Itemized In a separate table, a reference to that table is provided, Rev lew Plans Verified Field Variffe Value Value Complies? Camm&ntjzfAo!sum.pt1onj; 10311, Construction drawings and 1012 docurnentation d ornpiles demonstrate OD040 Not [PRIF energy code comollance for the buildlho envelope,Yhormal phot obsorvoble erlival'Opt f4prosion.tod on p lai A001c0le Construction dozurnamt!, 103,1, Construction drawings and omplies demonstrate Owes Not 14011 energy code -a Compliance for 1101iting and mochanica!systems: pivot 01boor voble :system.%nerving mainio UNot Applicable dwalling ijmlts trust demonstrate compIlince with the ie-ce Provioloms, 1:3023, Heating and cooling aqwIpment is Heatingi Heating; pcomplies 403.7 shed per ACOA Manual$'based $tU/hr—. Stu/hr— 0000s Not [PR211 on loads calculated. per ACOA coolimm Cooling; plot Observable Manual)or other methods Dtw/hr- QNot Applicable approved by the code official, Additional Comment*/Assumptionss 1!]High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: ZACurrent Client Projects\Witt\Stan hope Reside nce\sou rce\eng data\Stanhope-Energy Page 3 of10 Ca1c.rck Cti4rtiala ar' as ,arM ur 3fi�3 1 ' € and tit�rt nsg��*� I Z Valu 4t lu C rrspail ? can n, t f tism ai.i r 5 402,1,1 Conditionad basement wall Al ft� lie: ,See the Envelope Moombltao (F04)1 ih!gulstlon R'valuea Where lnterlor Dooms Not teble for valuff, Insulation,Is used;verification may need to Occur duringMNot�bservadi Insuiation In6pection, Not ONOt AppllcablA regWred in warm-humld locations in Climate Zone 3, 303,2 Conditioned basement wall I CoMPI le5 (l )' IMUlation Installod per 00oes Not manutacturer'S ln401ructioljs, ( Notiiervaele ONO Appllcnble �0 ,� ®ncllt9s l� d 6aseMan Wali r't t z3rl Alla at i tip ar�vat �A,6�0t t l% 1l;oell- Insulation dopth of banal or C-30 -'WesNot xatrta rvarus ; distance iro&,Top Of wall, Obsarvat3lo Ndt Applicbble ;303 2,1 A Votectl:ie covering is Installed complies iz0 protoct exposed extorlor Cf�ua�Not i��ulatIon and extonds a Minimum of 6 ib, below grade, t Ot 0sarvablc ONOt Appllca014 403,9 $now and lcaknlalllng systom Compll (F012)2 controls ln.%tallea, Moog%Not QNOt Observable, ONot Applicable Additional CaMMenito/AsSUMpltionlll l Nigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: ZACurrent Client Projects\VlWitt\Stanhope Reside nce\source\eng data\Stanhope-Energy Page 4 of 10 Calc.rck Section Framing !R4u h�-in Ins;ro6eVon' Plans3 4'erl#"letl Fi�E�I �erifs�cl 4otn}s?lis? t;Gsr mQY1U/A9-9U I)flX)9 �r R gIIiC7 value Value 402 1,1, Door U-factor, U• U- . (1Ooroplies $ee tbm Ento ope Asoe»bhao 402.3,4 �..,� _.� llDoo lot table for volueo, ONot C)bsenrsbla UNot Applicable ;402 1�1, Glaring U-factor(area-welghted lJ- U_ -.__ Crar+�i�lles Sea the Envelope Ag;,ca rbxas 4112.3,x; average), ck)oes Not table for values. 402,3,3, 4d2,a jNot Observable tRzl EINot Applicable 31533,3 U#actors of f0moStratition products i Compiles 11`1441; are determined In accordan.ca Qooes Not With the NFRC test proCedure or Not bser�ablfd taken from the default table, QNot 00ser albl 402 A U Ale barrier and th,anal bawl@@ �todr plle� SFR.2311 ln3tailed ppr l'anufaCturer'Il QD04%Nei; irlstm4� cls nil, Q.Not Observable QNot Applicable !402*� Fenestration that is not site builtplias fFR2d1+ is,listed and labeled as meatlr�g 0t�oes Not AAMA/WDMA/CSA 101/i,5,2/A44I [nkat bs�rval to car has Ir+filtratican rated pew NERC ONot,Applicable Opp that do not exceed coda limits. 9 2,4,9 IC-rated recessed lighting fixtures C s+�lpiles I(FR1612 sealed at housing/interlor finish 000es Not and labeled to Indicate asZ,p cfr ONot Observable leakage at 79 Ra, [; Not Applicable 403 3,1 Supply and return ducts In attics Gor»pIles [FRI21z insulated ;-4 R,$where duct Is C bees Not 3 inches in diameter and tp= R-6 where-; 3 Inches,Supply and l Nit Observable ` return ducts in other portions of ONot Applicable the building Insulated o-w R»6 for l diameter:p 3 Inches and R.4,2 for� 3 Inches iH diamneter, 4q3 3.9 Building cavities are not used a's Complies (FRIV ducts or Plenums, �Oats Not []Not Observable [ Not Applicable ..., _ ,. ,.. ...-. ._,... , , ...._... ........ 4014 HVAC piping conveying fluids �.ol�plies [FRIV above 105 QF or chilled fluids l�t�oss Not below 55 OF are Insuisted to kR- . 3, {Not Observable UNot,Applicable 403.4,1 protection of Insulation on HVAC las (FR2411 piping. 1200es Not (JNot Observable j ONot Applicable 403.5.3 Hot water pipes are Insulated to R-_ R- QComplies [FR1812 xR-3. lboes Not []Not Observable ©Nat Applicable 403.6 Automatic or gravity dampers are QComplies [FR1912 installed on all outdoor air []Does Not intakes and exhausts. [1Not Observable ©Nat Applicable 1 Nigh Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: ZACurrent Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page S of 1.0 Calc.rck Additional Comments/Assumption5i ......_. 1 High impact(Tier 1) 2 Medium Impact(Tier 2) 3 Lowy Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 6 of 10 Calc.rck ��ctla» rlrt JrlfliiiItltorlfies Y insulation ig ingpecrion value~ Value Corn Iles? n{�5r�y�rl��,r� R ir`tpp�3c�n� c,11 B0311 All IrtAWIed w6ul Oot!Is laWled i Cornplla (IN1312 or the Installed R-value% ODotg NOt provided, - Own Obsarvabla �ll+loti Applicabi ;402,1A, Wall OsUlation R value if this is s R� R�_ C or�tAll s $49 rn nv�tap As fhtblfa 402,24, Mass-41411 twltht at I44st'A of the- CWa)d EJ, Wood 0000;Not raws for vs/ug�. 402,2,€ wall insvistion ort thR gall [IN311 exterior,the exterior Imulatlon � Masr � Ma�� i�Not Obsarvsbla requirement applies(FRIO)� Steal ( Stool ONOt Applicable U312 all I10610tlort 15 I'notaliod per � ornpil�;3 [iR41 �Y�l nuta tJr r' InAtru0tlong, Does*Not QNOt 01304tVablo ONOt APPOCS1510 Additional 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) �3 Low Impact(Tier 3)y� Project Title: Stanhope Residence Report date: 04/17/18 Data filename: ZACurrent Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 7 of 10 Calc,rck 5ecu€s„ it?s; III>}5c: i€51f z�, f, i„r� tn 'v�r:f[*tiiterlPiutsYr2"1. .� R #1;993 Ua9caeAIIIf! t x�titYt }FJ#isi3�1JC)#t� 402,y,j, Colling Imsulat''lon A value. Ry �� I�CArr�plio� Seetha 0Jif*f*p4 Asse+ob,R-t Wood wood 1JD0es Not rablo f0f vd/uvo. 402,2,4eel dq�,2,o ON[it�i�.�e 9tsEs9 IMP ONot Applicable X03 1,1,2, Coiling IngulatiOn InStall4i�l0ods Not d per O-Corn ileo 30,x,2 rnenufaeturdr's Instruetlons, p (1=12)1 slowrt insulation marked Avery a0o fC , MNot Obsdrv,ble UNot Applicable.,. 402,2) Vdntod atflcs with air permosbie Corrlplies ritl2212 Insulation Include baffle adlecortt Does Not to Belt grid dave vents that exterldA over Insulation, Not Observable QNot Applicable 4021,4 attic Ac054 hatch and door } _ — ( Compiles '(FIV Irioulatloo %A-value of the �Does Not Adjacent ams?lhly, ONot oklservabid QNOt Applicable 402 4-1,2 Outer door teat Q 50 pa, 4g ,ACH 50 ACH-50 �C€� lplid 011711 Uh in CliFnAte ZAne.s 1*2, and moods Not 4-0 ach in Climate Zones M= _. QNot Observable : 4013,4 DUCt tightness test result of,4=4 cfn�/100 cfrr9/2d0 oo,pli i(141411 ctm/100 f12.across the-s SWIM or ftp . 0004;Not 3 cfm/100 ft2 wlihAuk alr handcar 0 25 Pa, For rough.4ri, ONot Observable tests,verification may need tg MNot Applicable i occur during Framing lnspeetion, 1403,3,3 putts Ara pressure tested to cfn9/100 cfrnl100 compiles 0127)3 determine sir leakage with ODoes Not either; Rough-in test.Total laakage measured with a ONot Observable pressure differential of 0,1 Inch ONot Applicable w,g,across the system Including the manufacturer's air handler enclosure If Installed at time of test,PoStcotlstructlon test;'total ceakago Measured with a pressure differential of 0,1 Inch w,g, across the entire system Including the manufacturer's air handler enclosure, 403,3:2,1 Alr handler leakage designated I Complies (12124)1 by manufacturer at o�a2 of 12Does Not design air flow, ONot 00servablo MNot,Applicable 403,1,1 Programmable thermostats _.._. ._. Co plies [Flp Installe€1 for control of primary QRoes Not heating and cooling systems and initially set by manufacturer to MNot Observable code specifications. [JNot Applicable 403,1,2 Heat pump thermostat Installed IOComplies 011012 on heat pumps, ❑Does Not ( Nat Observable E]Not Applicable .......... _.. . ..,. 403.5.1 Circulating service hot water ❑Complies [F111)2 systems have automatic or I-]Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 3 +Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: ZACurrent Client Projects\Mitt\Stanhope Residence\source\eng data\Stanhope-Energy Page 8 of10 Calc.rck ction Finial Ingriection Provi, 011ia fa t3 Vitrified i�lx�JS S1 If; �i com 116 %i?"ifT i iS'.�l did t )xIf7J7a 403.5,1 All roacharlical ventilation syatar» rvomplles M2512 fans not park of tasted and luted 000cf,Not HVAC equipment meet efficacy ��oa Observable and air flow limits, [Not Applicable 403 2 Not water bollen supplying heat LCprr�piles (FI26:12 through one-or two-pipe heating 000os Not aystom%have outdoor setback control to lower boiler waterHdt Observable temperature based on outdoor ONot Applicable ter��erature, 4d3 3,x,1 Heated water circulation syst:ams t orr plies [FI2SJJ have a 41rculatiori. pump,The 0120ea Not system return pipe is a dedlcatadIoti�servai return pipe or a cold water supply piped Gravity and the-rfrlos- �liR of Appilcable syphon clrcuiation systems ate moi'preaoni,Controls for elrculatinq hot water gyoteth pumps start the pump with signal for hot water demand within the occap�in�y, �oigtrols automatically turn off the pump when water is in orcuiatioh loop Is at set,polnt temperature and r10 der-Mand fgr hot water el€_IUM �y 4Q3eeieglectrlc heat trace systerl�s �Cornplles... _......_ _ _ 10`12911 comply with Me—X15,1 or UL C3l00es Not 515,controls automatically bdjyst the energy Input to the tnlotbservalle I heat tracing to rnalntsln the ONot Appllcable desired water temperature In the i _ piping r46,�, J-Water distribution systems that Compiles (F1301, have recirculation pumps that MOM Not pump water tram a heated water i supply pipe Dack to the heated ONot observable j wator sourca through a ,sold ONot Applicable watar oupply pipe have a demand recirculation wator symorn:pumps have controls that manage operation or the pump and limit the temperature of the water antering the cold water piping to 1040E 403,3.4 Drain water heat recovery units ��ornpllei itFI3112 tested In accordance with C5A 00oes Not 855,1, Potable water-side Nat Observable pressure loss of drain water heat [Not Applicable recovery units � 3 psi for Individual units connected to one or two showers,Potable water- side.Pressure loss of drain water heat recovery units e 2 psl for Individual units connected to three or more showers. 404,1 75%of lamps In permanent ocomplies (F16)1 fixtures or 75%of permanent Clpoes Not fixtures have high efficacy lamps. []Not Observable Does not apply to low-voltage lighting, ONot Applicable '404.1.1 Fuel gas lighting systems have OComplles (F12313 no continuous pilot light. Oc)oes Not j ONot Observable ©Not Applicable ----------------- 1 __ _------_. 1~High Impact(Tier 1) i 2 iMedium Impact(Tier 2) 3 iLow Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 9 of 10 Caic.rck Section FMAI In €?(t.1 n PrOVi5;bn '3'�iS v riffs i] tF if!o- Value value orr;isl:�s� i c�rnre:en al���urnii��i�ai�s ;40L3 Compilante cartificstie potted, L arn�li t�i7)� O�o:*a Nit O1�ioz obervable ONot tappilcable 303 Manufacturer manuals for O crnpli> V11639 mochanicai 4110 water ileatlng ODOR%Not sy%teas have been provided, ( Not Obser,labla ONot Appkable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) _ ! 3 Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename: Z:\Current Client Projects\Fitt\Stanhope Residence\source\eng data\Stanhope-Energy Page 10 of10 Calc.rck � - a�. T Above—trade Wall 21,00 Oelow-Ovado mall VS:0a plooe 000 Calling / Root A9, Window 0,27 boob' . .. EfficieIncy Heating Sy&tenii. tooling Systow wager Neatapa – r�.p 1✓�y fY���na ate°o Comments Christian a. augliera p.o. box 426 guilderland, NY, 12084 engineering 518.387.9480 4/17/2018 Ref: Stanhope Residence Country Club Drive Queensbury, NY 12804 Charles Dyer, Building Inspector Town of Queensbury Building Dept. %' 742 Bay Road Queensbury, NY 12804 This letter is to address your comments regarding the above mentioned residence. 1. Compliance to the 2015 International Energy Conservation Code and the 2016 supplement to the New York Energy Conservation Code shall be be demonstrated by the attached REScheck Compliance Certificate dated 4/17/2018. 2. It shall be deemed acceptable that the first floor deck is framed with 1-3/4"x 11-7/8" 1.5E Timberstrand LSL's at 16"o.c. in lieu of 11-7/8"I-joists at 16"o.c. Should you need further information, you can contact my associates or myself during normal business hours at the above number. Regards, OF NES, 0 CO `9 r U D Q m •• ,W Christian A. Augliera PE zs ` ? N.Y.S. License #090952 c� �O '6 0900 Ag0FES SIONP� 00� A, 4#S Weyerhaeuser 2012 IRC (R501.3)/ 2015 IRC (R302.13) FIRE PROTECTION OF FLOORS TRU ► JOIST PRODUCTS T ATI: FY CODE FIDE PROTECTION REQUIREMENTS TENT Floor sheathing CAN TJI`JOISTS BE USED TO SATISFY IRC FIRE PROTECTION REQUIREMENTS? T110 foists YES,Installing a gypsum membrane to the underside of Uls meets code requirements P�= for fire protection of floors.This makes TJls an excellent option for basements that will be finished.TJI joists are engineered for superior performance,and with several joist series ( and a variety of depths to choose from,a customized floor solution is always possible. Gypsum ceiling Trus Joists Floor sheathing CAN TIMBERSTRANDS` L.SL. BE USED TO SATISFY IRC TimberStrand" EIRE PROTECTION REQUIREMENTS? LSL floor joists YES.TimberStrand LSL floor joists with dimensions of 11/ x 9'/4"or larger satisfy Exception 4 of the fire protection code,eliminating the need for additional fire protection. TimberStrand LSL floorjoists are available in both 11/2'and 13/+"widths,and come in depths matching both sawn lumber and engineered lumber sizes to provide greater flexibility based on project needs.TimberStrand LSL floor joists also have larger allowable hale zones that can accommodate most residential plumbing and wiring needs. Trus Joist ;Y Floor sheathing CAN MICROL.L.AM@ LVL BE USED TO SATISFY IRC FIRE Micro llam" PROTECTION REQUIREMf NTS? LVL floor joists YES.Microllam LVL floor joists with dimensions of 13/0"x 91/4" or larger satisfy Exception 4 of the fire protection code,eliminating the deed for additional fire protection.Microllam LVL „ floor joists offer superior strength and stiffness,allowing for longer spans without the need for additional fire protection. ARE OTHER OPTIONS AVAILABLE YES.The IRC allows residential sprinklers to be used in lieu of membrane protection.In TO SATISFY CODE FIRE addition,APA-The Engineered Wood Association has published System Report(SR-405) with alternative fire protection details.TJI joists meeting the minimum web and flange PROTECTION REQUIREMENTS? sizes will perform equivalently to the joists specified.BUILDERS SHOULD CONSULT WITH THE LOCAL BUILDING OFFICIAL TO DETERMINE THE SUITABILITY OF THE DETAILS SHOWN PRIOR TO STARTING CONSTRUCTION. CONTACT US 888.453.5358 WEYERHAEUSER.COIVI/WOODPRODUCTS PRODUCT WARRANTY" July 2017,. AWeyerhaeuser,TimberStrand Tll and Trus Joist are registered trademarka of Weyerhaeuser NR. ( �. -r-- ^^^^•« Reerdel"U-9413 C 2017 Weyethaeuser NR eampany.Ak rlgnts remved. NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION Division of Natural Resources,Region 5 232 Golf Course Road,Warrensburg,NY 12885 P:(518)623-1203 1 F:(518)623-3603 www.dec.ny.gov Mr. David Stanhope 127 Grant Ave. Ext. Queensbury,NY 12804 Re: Wetland Delineation Sweet Road & Country Club Road, TP#296.15-1-1 Queensbury(T),Warren (Co) Dear Mr. Stanhope, On October 15th, 2015,NYSDEC staff inspected the above-described property located on the corner of Sweet Road and Country Club Road, in the town of Queensbury, Warren County. The Purpose of the inspection was to delineate the boundary of state-regulated freshwater wetland GF- 23. The actual wetland boundary was determined to differ slightly from what is mapped by the DEC. The actual wetland boundary is marked in red on the attached map. Please note that the 100 foot regulated adjacent area starts at the bottom of the hill and cannot accurately be shown on the map. A Freshwater Wetlands Permit from the DEC is required to conduct a regulated activity in the wetland or the 100-foot adjacent area surrounding the wetland. Some regulated activities include placement of fill, excavation, and clear cutting of vegetation. Whether or not a freshwater wetlands permit will be required, you are responsible for determining if any other local, state or federal permits are required for development of this property. For information regarding permits administered by the Department of Environmental Conservation,please contact the Division of Environmental Permits at 518-623-1200. For information regarding freshwater wetlands and permits administered by the United States Army Corps of Engineers, contact their office in Troy at 518-270-0588. Thank you for your inquiry and the opportunity to serve you. If you have any questions regarding the Freshwater Wetlands Law or Regulations,please contact me at 518-623-1245, or visit the DEC website at the address above. Sincerely, Brittany DeLor Wildlife Technician NEW YORK Department of STATE°` Environmental OPPORTUNITY Conservation ti Witt - Stanhope HVAC Load Calculations for Witt Construction 563 North Broadway Saratoga New York FILE COPY RESIDEN7YAL H V HVAC LOADS 296.15-1-1 RC-000065-2017 Stanhope, David & Morgan 148 Sweet Road SFD w/FP 3099 s.f., Garage 505 s-f. Prepared By. Joe Van Buren Highland Home Heating& Cooling,llc Po Box 2317 Wilton New York 518.583.4187 Tuesday,April 4,2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. y Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc, Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 2 ------- ---- — Project Report - ------ ------- General Project Information Project Title: Witt- Stanhope Designed By. Joe Van Buren Project Date: Saturday, March 25, 2017 Client Name. Witt Construction Client Address: 563 North Broadway Client City: Saratoga New York Client Phone: 518.587.4113 Client E-Mail Address: bnathan@wittconstruction.com Company Name: Highland Home Heating & Cooling,lic Company Representative: Joe Van Buren Company Address: Po Box 2317 j Company City: Wilton New York I Company Phone: 518.583.4187 Company E-Mail Address: joe@highlandandco.com Company Website: www.highlandandco.com Design Data Reference City: Glens Falls, New York Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 43 Degrees Elevation: 328 ft. Altitude Factor: 0.988 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -4 -4.56 n/a 30% 70 29.33 Summer: 85 71 51% 50% 72 34 Check Fi un __ Total Building Supply CFM: 887 CFM Per Square ft.: 0.329 Square ft. of Room Area: 2,699 Square ft. Per Ton: 1,034 Volume (ft'): 25,844 building Loads .. . Total Heating Req_uired Including Ventilation Air: 68.799 Btuh 68.799 MBH Total Sensible Gain: 21,075 Btuh 67 % Total Latent Gain- 10,237 Btuh 33 % Total Cooling Required Including Ventilation Air: 31,313 Btuh 2.61 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computqgr program - Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i C:\Users\Joe\DocumentsElite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM . , Rhvac-Residential&Light Commercial HVAC Loads Elks S lopffont.Inc. Highland Home Heating&Cooling Witt-Stmhope Wilton, NY 12831 P20a 31 Miscellaneous Report system 1 Outdoor Outdoor Outdoor Indoor Indoor � | Data «e� | � ----- �-----------��---�� 4�SG 809& 3U96 70 uyuu | Summor. 85 71 51% 58% 72 3338 � Duct Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yeo Yes Roughness Factor 0.00300 0,01000 � Pressure Drop: 01000 in.wg./10Oft. 01000 in.wg/180fL Minimum Velocity: 650 ft./min 450 ft./min � Maximum Velocity: 900 ft./min 750 ft./min | Minimum Height: 5 in. 5 in | Maximum Height: 8 in. G in. OutsideAirData Winter Surnme | Infiltration Specified: 0110 AC/hr 0.060 AC/hr 47 CRN %G CFM Infiltration Acua|: 0.253 AC/hr 0,752 AC/hr Above Grade Vo|ume� X_25,1844 Cu.ft. X 25,84 Cu.M � 6.531 Cu,ft./hr —��19.442 Cu.ft./hr � X10,0167 X 0.0167 Total Building Infiltration: 189 CFM 324 CFM Total Building Ventilation. 127 CFM 127 CFM --System I--- Infiltration &Vanti|adon Sensible Gain Multiplier: 14.13 = (1.10X O988 X 1300 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 22.70 = (O.GDXO�Q88% 33JBGrains Difference) ! Infiltration &Venti|ation Sensible Loss Multiplier: 80.44 = (110X0.988X 74.DOWinter Temp. Difference) Winter Infiltration Specified: O110AC/hr(47CFKA). Construction: Tight � Summer Infiltration Specified: 0.O6OAC/hr(ZGCFM). ConoimoUon: Tight | � � � � | | � ---- Stanhope rhQ Tuemdoy, April 4 2017 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads _ Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 4; Load Preview Report i Net ft' Sen Lat Net Sen'. Sys Sys Sys Duct CFM: CFM: Scope Tom /Ton Area Gain; Gain Gain Loss' Htg; FM. Act CFM Size Building 2.61 1,034 2,699 21,075 10,237 31,313 68,799 770 887 887 System 1 2.61 1.034 2.699 21,075 10.237 31,313 68.799 770 887 887 22x8 Ventilation 1.795 2.882 4,677 10.216 Humidification 3.436 Zane 1-Cig. 55-'�, Htg_: 55 1 557 13,318 4.198 17,516 30.474 425 613 613 16x8 1-Famiy Room 289 3,445 870 4,315 7,492 105 158 158 1-6 2-First Floor Bath 96 716 512 1228 2,492 35 33 33 1--5 3-Entry Foyer 96 341 205 546 1.141 16 16 16 1-5 4-Pantry 84 530 307 837 1,807 25 24 24 1-5 5-Kitchen 420 2,486 537 3,023 4,945 69 114 114 14 6-Master Bath 160 1,414 205 1,619 2,424 34 65 65 1-5 7-First Floor Master Bedroom 180 3,102 691 3,793 5,805 81 143 143 1-6, S-Walk In Closet 72 160 154 314 613 9 7 7 1-5 9-Side Hall 64 749 512 1261 2,462 34 34 34 1-5 i 10-Stair Landing Area 96 375 205 580 1293 18 17 17 1-5 Zane 2-Clg 45F,_ Htg.:45"• 1 142 10,857 3.157 14.014 24.673 344 499 499 14x8 11-Upstairs Front Bedroom 176 1,868 622 2.490 5,111 71 86 86 1-5 12-Upstairs Bathroom 90 352 154 506 897 13 16 16 1-5 13-Upstairs Rear Bedroom 156 2,318 576 2,894 4.377 61 107 107 1-6 14-Upstairs Master Walk In Closet 154 527 253 780 1307 18 24 24 1-5 15-Upstairs Master Bedroom 230 3.608 700 4,308 6281 88 166 166 2--5 16-Upstairs Master Bath 208 1,166 668 1,834 3:692 52 54 54 1-5 17-Upstairs Stair/HallWay 128 1,017 184 1201 3,008 42 47 47 1-5 I i Sum of room airflows may be greater than system airflow because system has multiple zones. I i C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton, NY 12831 Page-15. Duct Size Preview Room or SMinimum Maximum Rough. Design SP Duct Duct Htg Clg Act Duct Source Duct Name Velocity Velocity Factor L/100 Loss VelocityLength Flow Flaw Flow Size System 1 Supply Runouts j Zone t 1-Family Room Built-In 450 750 0.01 0.1 807 105 158 158 1-6, 2-First Floor Bath Built-In 450 750 0.01 0.1 241.5 35 33 33 1-5 3-Entry Foyer Buift-In 450 750 0.01 0.1 115.1 16 16 16 1-5 4-Pantry Built-In 450 750 0.01 0.1 178.8 25 24 24 1-5 5-Kitchen Built-In 450 750 001 0.1 582.3 69 114 114 1.6 6-Master Bath Built-In 450 750 0.01 0.1 477.1 34 65 65 1-5(i( 7-First Floor Master Bedroom Built-in 450 750 0.01 0.1 726.6 81 143 143 1-61 i 8-Walk In Closet Built-In 450 750 0.01 0.1 54.1 9 7 7 1-5 9-Side Hall Built-In 450 750 0.01 01 252.8 34 34 34 1,-5 10-Stair Landing Area Built-In 450 750 0.01 0.1 126.4 18 17 17 1-51 Zone 2 11-Upstairs Front Bedroom Built-In 450 750 0.01 0.1 630.2 71 88 86 1-5 12•UpstairsBathroom Built-In 450 750 001 0.1 118.9 13 16 16 1-5 13-Upstairs Rear Bedroom Built-In 450 750 0.01 0.1 543 61 107 107 14 14-Upstairs Master Walk In Closet Built-In 450 750 0.01 0.1 177.8 18 24 24 1-5 15-Upstairs Master Bedroom Built-in 450 750 0.01 0.1 608.6 88 166 166 2-51 16-Upstairs Master Bath Built-In 450 750 0.01 0.1 393.2 52 54 54 1-51 17-Upstairs Stair/Hall Way Built-In 450 750 001 01 343.2 42 47 47 1-5 1 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 725.6 770 -"'887 887 22x8 Summary System 1 Heating Flow: 770 Cooling Flow: 887 I I C:\Users\Joe\Documents\Elite Software\Rhvac 9 ProjectsMitt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc, Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 6_ Total Building Summary Loads ------ ComponentArea -._sen_ Lat Sen - Total DescriptionQuan Loss Gain Gain Gain 1A-ry-o: Glazing-Single pane, operable window, 413.9 27,566 0 10,705 10,705 reflective; vinyl frame, u-value 0.9, SHGC 0.3 11P: Door-Metal- Polyurethane Core 81.9 1,758 0 570 570 12D1-0bw: Wall-Frame, R-21 closed cell 2 Ib. spray foam 2377.8 13,372 0 1,807 1,807 insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 176 260 0 169 169 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 16CR-50: Roof/Ceiling-Under Attic with Insulation on Attic 965.6 1,429 0 733 733 Floor(also use for Knee Walls and Partition Ceilings); Vented Attic with Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 19D-Osp: Floor-Over enclosed crawl space. R-19 1557 2,005 0 352 352 insulation on exposed walls, sealed crawl space, passive, no floor insulation, carpet or hardwood Subtotals for structure: 46,390 0 14,336 14,336 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 109, Summer CFM: 324 8,757 7,355 4,580 11,935 Ventilation: Winter CFM: 127, Summer CFM: 127 10,216 2,882 1,795 4.677 Exhaust: Winter CFM: 225, Summer CFM: 450 Humidification (Winter) 9.37 gal/day : 3,436 0 0 0 AED Excursion: 0 0 365 365 Total Building Load Totals: 68,799 10,237 21,075 31,313 Total Building Supply CFM: 887 CFM Per Square ft.: 0.329 Square ft. of Room Area: 2,699 Square ft. Per Ton: 1,034 Volume (ft'): 25,844 Building oa lds Total Heating Required Including Ventilation Air: 68,799 Btuh 68.799 MBH Total Sensible Gain: 21,075 Btuh 67 % Total Latent Gain: 10,237 Btuh 33 % Total Cooling Required Including Ventilation Air: 31,313 Stuh 2.61 Tons(Based On Sensible +Catent) Notes _ _ Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4; 2017, 3:48 PM e Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating 8 Cooling Witt-Stanhope Wilton,NY 12831 _Page 7 Building Pie Chart Flog 3% Humidification 5% Roof 2% Ventilation 15% Wall 19% Building Loss 68,799 - Infiltration 13% Btuh Door 3% Glass 40% F110/(o 6�/oof 39/1 o AED Excursion 1 Ventilation 15% t Building Gain 31,313 Glass 34% Btuh Infiltration 38% Door 2% C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM f Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 System 1, Zone 1 Pie Chart Floor 7% Infiltration 16% Wall 25% Door 6% System 1 , Zone 1 Loss 30,474 Btuh Glass 46% Wall Floor2% AED Excursion 1% System Infiltration 39% 1 , Zone 1 Gain 17,516 Btuh Glass 49% Door 3% C:\Users\Joe\Documents\Elite Software\Rhvac 9 ProjectsMitt- Stanhope.rh9 Tuesday,April 4, 2017, 3:48 PM i Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.' Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 MV Page 9 System 9, Zone 2 Pie Chart Roof 7% Infiltration 15% Wall 24°l0 System 1 , Zone 2 Loss 24,673 Btu h Glass 54% Roof 6% AED Excursion 1% Wall 6% Infiltration 37% System 1 , Zone 2 Gain 14,014 Btu h Glass 50% ,I C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017 3:48 PM Rhvac-Risidential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton. NY 12831 Page 10 Detailed Room Loads - Room 1 - Family Room (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 2 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 17.0 ft. Zone Number: 1 Area: 289.0 sq.ft. Supply Air: 158 CFM Ceiling Height: 10.0 ft. Supply Air Changes. 3.3 AC/hr Volume: 2,890 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 17 CFM Runout Air: 158 CFM Percent of Supply.: 11 % Runout Duct Size: 6 in. Actual Summer Vent.: 18 CFM Runout Air Velocity: 807 ft./min. Percent of Supply: 11 % Runout Air Velocity: 807 ft./min. Actual Winter Infil.: 13 CFM Actual Loss 0.411 in.wg./100 ft. Actual Summer Infil.: 38 CFM Item Area -U- Htg Sen -Clg Lat Sen Description Quantity _ Value HTM Loss HTM Gain Gain S-Wall-12D1-Obw 17 X 10155.6 0.076 - 5.6 875 - - 0.$ 0 118 E-Wall-12D1-Obw 17 X 10 116 0.076 5.6 652 0.$ 0 88 S -GIs-1A-ry-o shgc-0.3 O%S (3) 14.4 0.900 66.6 960 47.5 0 684 E -GIs-1A-ry-o shgc-0.3 O%S (3) 54 0.900 66.6 1597 351 0 1,896 Floor-19D-Osp 17 X 17 289 0.368 1.3 372 02 0 65 Subtotals for Structure: 6,456 0 2,851 Infil.: Win.: 12.9, Sum.: 38.3 340 3.047 1,036 1.594 870 542 Ductwork: 0 0 AED Excursion: 52 ......._..._....... Room Totals: 7,492 870 3,445 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017.. 3:48 PM Rhvac-Residential&light Commercial HVAC Loads Elite Software Development,Inca Highland Home Heating&Cooling Witt-Stanhope Wilton, NY 12831 Page 11 Detailed Room Loads - Room 2 - First Floor Bath (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 2 pm Calculation Mode. Htg. &clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area. 96.0 sq.ft. Supply Air 33 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.1 AC/hr Volume: 960 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers 1 Actual Winter Vent.: 6 CFM Runout Air: 33 CFM Percent of Supply.: 17 % Runout Duct Size: 5 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 241 ft./min. Percent of Supply: 11 % Runout Air Velocity: 241 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.049 in.wg./100 ft. Actual Summer Infil.: 23 CFM Item Area -U- �Htg Sen Clg Let Sen DescriptionQuantity Value HT_M Loss HTM Gain Gain E _Wall-12D1-0bw 12 X .1.0 _ _.. 120 0.076 u 5.6 v._._ 675 0.8 0 91 N -Wall-12D1-Obw 8 X 10 69.6 0.076 5.6 391 0.8 0 53 N -GIs-1A-ry-o shgc-0.3 0%S 10.4 0.900 66.6 693 21.2 0 220 Floor-19D-Osp 8 X 12 96 0.368 1.3 124 0.2 0 22 Subtotals for Structure. 1.883 0 386 Infil.: Win.: 7 6, Sum.: 22.6 200 3.045 609 1.595 512 319 Ductwork: 0 0 AED Excursion: 11 Room Totals: 2,492 512 716 C\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM - -- Rhvac-Residential— &Light Commercial HVAC Loads � Elite Software Oevelapment,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton, NY 12831 Page 12 Detailed Room Loads - Room 3 - Entry Foyer (Peak Fenestration Gain Procedure) General -- -_ _ Room is in zone 1, which peaks at 2 pm Calculation Mode Htg. &clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 96.0 sq.ft. Supply Air: 16 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.0 AC/hr Volume. 960 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 16 CFM Percent of Supply.: 17 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 115 ft./min. Percent of Supply: 11 % Runout Air Velocity: 115 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.012 in.wg./100 ft. Actual Summer Infil,: 9 CFM Item _ Area -U- Htg Sen Clg Lat Sen Description Quantity Value HTM LossHTM Gain Gain N -Wall-12D1-Obw 8 X 10 59.6 0.076 -- �5.6 335 0.8 0 45 N -Door-11 P 3 X 6.8 20.4 0.290 21.5 438 7.0 0 142 Floor-19D-Osp 8 X 12 96 0.368 1.3 124 0.2 0 22 Subtotals for Structure: 897 0 209 Infil.: Win : 3.0. Sum.: 9.0 80 3.050 244 1.588 205 127 Ductwork: 0 0 AED Excursion: 5 . . .............._....... Room Totals: 1,141 205 341 I C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads _._ Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 13 Detailed Room Loads - Room 4 - Pantry (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at—2pm Calculation Mode: Htg, &clg. Occurrences: 1 Room Length: 7.0 ft. System Number, 1 Room Width: 12.0 ft Zone Number: 1 Area: 84.0 sq.ft. Supply Air: 24 CFM Ceiling Height. 10.0 ft. Supply Air Changes: 1.7 AC/hr Volume 840 cu.ft. Req. Vent, Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 24 CFM Percent of Supply.: 17 % Runout Duct Size: 5 in. Actual Summer Vent.. 3 CFM Runout Air Velocity: 179 ft.lmin. Percent of Supply: 11 % Runout Air Velocity: 179 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.028 in.wg./100 ft. Actual Summer Infil.. 14 CFM Item _- - - Area U- Htg Sen,. Clg. - -Lat- -Sen 6Description Quantity Value HTM Loss H`FM Gain Gain N-Wall-12D1.Obw 12 X 10_ 109.2 0.076 5.6 614 0.8 -- 0 -____-- 83 N -GIs-1A-ry-o shgc-0.3 0%S 10.8 0.900 66.6 719 21.2 0 229 Floor-19D-Osp 12 X 7 84 0.368 1.3 108 0.2 0 19 Subtotals for Structure: 1,441 0 331 Infil.: Win.: 4.5, Sum.: 13.5 120 3.050 366 1.592 307 191 Ductwork: 0 0 AED Excursion: 8 Room Totals: 1,807 307 530 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton, NY 12831e 14 Detailed Room Loads - Room 5 - Kitchen (Peak Fenestration Gain Procedure) General Room is in zone 1.. which peaks at 2 pm Calculation Mode Htg &clg. Occurrences: 1 Room Length: 21.0 ft. System Number: 1 Room Width: 20.0 ft. Zone Number: 1 Area: 420.0 sq.ft. Supply Air, 114 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.6 AC/hr Volume: 4,200 cu.ft. Req. Vent. Clg. 0 CFM Number of Registers: 1 Actual Winter Vent.: 11 CFM Runout Air: 114 CFM Percent of Supply.: 10 % Runout Duct Size: 6 in. Actual Summer Vent. 13 CFM Runout Air Velocity: 582 ft./min. Percent of Supply: 11 Runout Air Velocity: 582 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.215 in.wg./100 ft. Actual Summer Infil.: 24 CFM Item Area -U Htg - Sen--� Clg Lat Sen Description Quanti Value HTM Loss HTM Gain Gain S -Wall-1 2D1-Obw 21 X 10 152.3 0.076 5.6 857 0.8 0 116 S -Door-11 P 3 X 6.9 20.7 0.290 21.5 444 7.0 0 144 S-GIs-lA-ry-o shgc-0.3 0%S 25 0.900 66.6 1,665 47.5 0 1,188 S -GIs-lA-ry-o shgc-0.3 0%S 12 0.900 66.6 799 47,5 0 570 Floor-19D-Osp 20 X 21 420 0.368 1.3 540 0.2 0 95 Subtotals for Structure. 4,305 0 2,113 Infil.: Win.: 8 0, Sum.: 23.7 210 3.048 640 1.595 537 335 Ductwork: 0 0 AED Excursion: 37 Room Totals: 4,945 537 2,486 i C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads - Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 15_ Detailed Room Loads Room 6 - Master Bath (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences 1 Room Length. 20.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 160.0 sq.ft. Supply Air: 65 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 1,600 cu.ft Req. Vent. Clg: 0 CFM Number of Registers. 1 Actual Winter Vent.: 6 CFM Runout Air: 65 CFM Percent of Supply.: 9 % Runout Duct Size: 5 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 477 ft./min. Percent of Supply: 11 % Runout Air Velocity: 477 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.187 in.wg./100 ft. Actual Summer Infil.: 9 CFM Item Area --_ U_ .._Htgm Sen - CIg_ lat ------Sen Description ____ Quantity Value _HTM Loss HTM_ Gain Gain -W ' S all-1261-Obw 8 X 10 55 0.076 5.6 309 O,8 0 42: S -GIs-1A-ry-o shgc-0.3 0%S 25 0.900 66.6 1,665 47.5 0 1,188 Floor-19D-Osp 8 X 20 160 0.368 1.3 206 0.2 0 36 Subtotals for Structure: 2.180 0 1,266 Infil.: Win.: 3.0, Sum.: 9.0 80 3.050 244 1.588 205 127 Ductwork: 0 0 AED Excursion: 21 Room Totals. 2,424 205 1,414 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope: Wilton,NY 12831 Page 16_ Detailed Room Loads - Room 7 - First Floor Master Bedroom (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 180.0 sq.ft. Supply Air: 143 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 4.8 AC/hr Volume. 1,800 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 13 CFM Runout Air: 143 CFM Percent of Supply.: 9 % Runout Duct Size: 6 in. Actual Summer Vent.: 16 CFM Runout Air Velocity: 727 ft./min. Percent of Supply: 11 % Runout Air Velocity: 727 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.334 in.wg./100 ft. Actual Summer Infil., 30 CFM Item ;Area -U- Htg Sen Clg Lat Sen i Description Quantit y Value HTM Loss ' HTM__ Gain Gain; S -Wail-12D1-Obw 12 X 10 75 0.076 5.6 422 0.8 0 57 W-Wall-12D1-Obw 15 X 10 142 0.076 5.6 799 0.8 0 108 S-GIs-lA-ry-o shgc-0.3 0%S (3) 45 0.900 66.6 2,997 47.5 0 2,139 W-GIs-1A-ry-o shgc-0.3 0%S (2) 8 0.900 66.6 532 35.0 0 280 Floor-19D-Osp 12 X 15 180 0.368 1.3 232 0.2 0 41 Subtotals for Structure: 4,982 0 2,625 Infil.: Win.: 10.2, Sum.: 30.4 270 3.048 823 1.593 691 430 Ductwork: 0 0 AED Excursion: __ 47 Room Totals. 5,805 691 3,102 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton NY 12831 Page 17 Detailed Room Loads - Room 8 - Walk In Closet (Peak Fenestration Gain Procedure) General Room is in zone 1. which peaks at 2 pm Calculation Mode. Htg. &clg. Occurrences: 1 Room Length. 12.0 ft. System Number. 1 Room Width: 6-0 ft. Zone Number: 1 Area. 72.0 sq.ft. Supply Air 7 CFM Ceiling Height. 10-0 ft. Supply Air Changes: 0.6 AC/hr Volume: 720 cu.ft. Req. Vent, Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 7 CFM Percent of Supply.: 19 % Runout Duct Size: 5 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 54 ft./min. Percent of Supply: 11 % Runout Air Velocity: 54 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.003 n.wg./100 ft. Actual Summer Infil,: 7 CFM Item Area -U Htg Sen Cig Lat Sen Description Quantity Value HTM Loss HTM Gain Gain ---_ W-Wall-12D1 Obw 6 X 10 __.. -60 0,076 5.6 337 0.8— -- 0 46 Floor-190-Osp 6 X 12 72 0.368 1.3 93 0.2 0 16 Subtotals for Structure: 430 0 62 Infil.: Win.: 2.3, Sum.: 6.8 60 3.050 183 1.600 154 96 Ductwork: 0 0 AED Excursion: 2 Room Totals: 613 154 160 �I C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 18 ---- -------- Detailed Room Loads - Room 9 - Side Hall (Peak Fenestration Gain Procedure) Room is in zone 1, which peaks at 2 pm w Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width 4.0 ft. Zone Number: 1 Area: 64.0 sq.ft. Supply Air: 34 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.2 AC/hr Volume: 640 cu.ft. Req. Vent. Clg 0 CFM Number of Registers: 1 Actual Winter Vent.: 6 CFM Runout Air: 34 CFM Percent of Supply.: 16 % Runout Duct Size: 5 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 253 ft./min. Percent of Supply: 11 % Runout Air Velocity: 253 ft./min. Actual Winter lnfil.: 8 CFM Actual Loss. 0.054 in.wg./100 ft. Actual Summer Infil.: 23 CFM Item Area -U- Htg Sen Clg Lat Sen Description Quantity Value HTM Loss HTM Gain Gain W-Wall-12D1-Obw 4 X 10 19.6 0.076 5.6 110 0.8 0 15 N -Wall-12D1-Obw 16 X 10 139.6 0.076 5.6 785 0.8 0 106 W-Door-11 P 3 X 6.8 20.4 0.290 21.5 438 7.0 0 142 N -Door-11 P 3 X 6.8 20.4 0.290 21.5 438 TO 0 142 Floor-19D-Osp 4 X 16 64 0.368 1.3 82 0.2 0 14 Subtotals for Structure: 1,853 0 419 Infil.: Win : 7.6. Sum.. 22.6 200 3.045 609 1.595 512 319 Ductwork: 0 0 AED Excursion: 11 Room Totals: 2,462 512 749 I C:\Users\Joe\Documents\Elite SoftwarelRhvac 9 Projects\Witt-Stanhope rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton, NY 12831 Page 19 Detailed Room Loads - Room 10 - Stair Landing Area (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 12.0 ft, System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 96.0 sq,ft. Supply Air: 17 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.1 AC/hr Volume. 960 cu ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 17 CFM Percent of Supply.: 17 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 126 ft./min. Percent of Supply: 11 % Runout Air Velocity: 126 ft./min Actual Winter Infil- 3 CFM Actual Loss: 0.014 in.wg./100 ft. Actual Summer Infil.: 9 CFM {Item Area .U_ __. Htg Sen cig Lat Sen Description Quantity Value HTM Loss HTM Gain Gain N -Wall-12D1-Obw 8 X 10 72.2 0,076 5.6 406 0.8 0 55 N -GIs-1A-ry-o shgc-0.3 0%S 7.8 0.900 66.6 519 21.2 0 165 Floor-19D-Osp 8 X 12 96 0.368 1,3 124 0.2 0 22 Subtotals for Structure: 1,049 0 242 Infil.: Win.: 3.0, Sum.. 9.0 80 3.050 244 1.588 205 127 Ductwork: 0 0 AED Excursion: 6 Room Totals: 1,293 205 375 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton.NY 12831 Detailed Room Loads - Room 11 - Upstairs Front Bedroom (Peak Fenestration Gain Procedure) General Room is in zone 2, which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 11.0 ft. System Number. 1 Room Width: 16.0 ft. Zone Number: 2 Area: 176.0 sq.ft. Supply Air: 86 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 3.3 AC/hr Volume: 1,584 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 12 CFM Runout Air: 86 CFM Percent of Supply.: 14 % Runout Duct Size: 5 in. Actual Summer Vent.: 10 CFM Runout Air Velocity: 630 ft./min. Percent of Supply: 11 % Runout Air Velocity: 630 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.325 in.wg./100 ft, Actual Summer infil.: 27 CFM Item Area -U- _Htg Sen Clg Lat Sen Description Quantity Value HT_M Loss HTM Gain Gain N -Wall-1251-Obw 16 X_9 __ 112 0.076 --6.6 630 0.8 0 85 E-Wall-1 2D1-Obw 11 X 9 86 0.076 5.6 484 0.8 0 65 N -GIs-1A-ry-o shgc-0.3 0%S 32 0.900 66.6 2,131 21.2 0 678 E -GIs-1A-ry-o shgc-0.3 0%S 13 0.900 66.6 866 35.1 0 456 UP-Ceil-16B-50 11 X 16 176 0.020 1.5 260 1.0 0 169 Subtotals for Structure: 4,371 0 1,453 Infil.: Win.: 9.2, Sum.: 27.4 243 3.045 740 1 593 622 387 Ductwork: 0 0 AED Excursion: 28 Room Totals: 5,111 622 1,868 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday,April 4, 2017. 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Sottware Development,Inc. Highland Home Heating&Cooling Witt Stanhope Wilton, NY 12831 Page 21 Detailed Room Loads - Room 12 - Upstairs Bathroom (Peak Fenestration Gain Procedure) - -- - General Room is in zone 2:which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 2 Area: 90.0 sq.ft. Supply Air: 16 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 1.2 AC/hr Volume: 810 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 16 CFM Percent of Supply.: 13 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 119 ft./min. Percent of Supply: 11 % Runout Air Velocity: 119 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.013 in.wg.1100 ft. Actual Summer Infil.: 7 CFM Item Area -U- Htg - Sen Clg tat Sen Description Quantity Value HTM loss HTM Gain Gain - _ E -Wall 12D1-Obw 6 X 10 0.8 56� 0.076 5.6 315 0 43 E -GIs-1A-ry-o shgc-0.3 0%S 4 0.900 66.6 266 35.0 0 140 UP-Ceil-16CR-50 15 X 6 90 0.020 1.5 133 0.8 0_ 68 Subtotals for Structure: 714 0 251 Infil.: Win., 2.3, Sum.. 6.8 60 3.050 183 1.600 154 96 Ductwork: 0 0 AED Excursion: 5 Room Totals. 897 154 352 I I C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017, 3:48 Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Coolinga, Witt-Stanhope Wilton,NY 12831 Page 22 Detailed Room Loads - Room 13 - Upstairs Rear Bedroom (Peak Fenestration Gain Procedure) i General - -- -_ Room is in zone 2, which peaks at 2 pm Calculation Mode: Htg. &cig. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 2 Area. 156.0 sq.ft. Supply Air: 107 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 4.6 AC/hr Volume: 1,404 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers. 1 Actual Winter Vent.: 10 CFM Runout Air: 107 CFM Percent of Supply.: 9 % Runout Duct Size: 6 in. Actual Summer Vent,: 12 CFM Runout Air Velocity: 543 ft./min. Percent of Supply: 11 % Runout Air Velocity: 543 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.188 in.wg./100 ft. Actual Summer Infil.: 25 CFM Item Area -U- Htg. Sett Cig :Lat Sen Description Quantity Value HTM Loss HTM Gain Gain S -Wall-1 2D1-Obw 13 X 9 85 0.076 5.6 478 0.8 0 65 E -Wall-1201-Obw 12 X 9 104 0.076 5.6 585 0.8 0 79 S -GIs-1A-ry-o shgc-0.3 0%S 32 0.900 66.6 2,131 47.5 0 1,521 E -GIs-1A-ry-o shgc-0.3 O%S 4 0.900 66.6 266 35.0 0 140 UP-Ceil-16CR-50 12 X 13 156 0.020 1,5 231 0.8 0 119 Subtotals for Structure: 3,691 0 1,924 Infil.: Win.: 8,5, Sum.: 25.4 225 3.049 686 1,596 576 359 Ductwork: 0 0 AED Excursion. 35 Room Totals. 4,377 576 2,318 l i I i I I i C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residentia1-1-Lig ht Commercial HVAC Loads — Elite Software Development,Mc. Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Detailed Room Loads - Room 14 - Upstairs Master Walk In Closet (Peak Fenestration Gain Procedure) General Room is in zone 2, which peaks at 2 pm Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room Width: 11.0 ft. Zone Number. 2 Area: 1540 sq.ft. Supply Air: 24 CFM Ceiling Height: 90 ft. Supply Air Changes: 1.0 AC/hr Volume: 1,386 cu.ft Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 24 CFM Percent of Supply.: 12 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 178 ft./min. Percent of Supply: 11 % Runout Air Velocity: 178 ft./min. Actual Winter Infil..- 4 CFM Actual Loss: 0.027 in.wg./100 ft. Actual Summer Infil.: 11 CFM Iterr_�� .___ Area -_ `U+___ ___._.Htg Sen Clg Let Sen Description Quantity Value HTM Loss HTM Gain Gain S -Wall-12D1-Obw 11 X 9 95.4 0.076 5.6 537 0.8 0 73 S -GIs-1A-ry-o shgc-0.3 0%S 3.6 0.900 66.6 240 47.5 0 171 UP-Ceil-16CR-50 14 X 11 154 0.020 1.5 228 0.8 0 117 Subtotals for Structure: 1,005 0 361 Infil.: Win.: 3.8, Sum.: 11.2 99 3.051 302 1.596 253 158 Ductwork: 0 0 AED Excursion: 8 Room Totals. 1,307 253 527 I C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017. 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton,.NY 12831 - ---- - - - ----- Page 24 Detailed Room Loads - Room 15 - Upstairs Master Bedroom (Peak Fenestration Gain Procedure) General Room is in zone 2 which peaks at 2 pm Calculation Mode. Htg. & clg. Occurrences: 1 Room Length. 16.4 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 2 Area: 229.6 sq.ft. Supply Air. 166 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 4.8 AC/hr Volume. 2,066 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 14 CFM Runout Air: 83 CFM Percent of Supply.: 9 % Runout Duct Size: 5 in, Actual Summer Vent.. 19 CFM Runout Air Velocity: 609 ft./min. Percent of Supply: 11 % Runout Air Velocity_ 609 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.303 in.wg./100 ft. Actual Summer Infil.: 31 CFM item _.._ Area -U- Htg Sen Gig Lat Sen DescriptionQuantity Value HTM Loss HTM Gain Gain - S-Wall-12D1-Obw 14 X 9 __� -67.5 0.076 5.6 380 0.8 0 51 W-Wall-1201-Obw 16.4 X 9 147.6 0.076 5.6 830 0.8 0 112 S-GIs-1A-rv-o shgc-0.3 0%S (3) 58.5 0.900 66.6 3,897 47.5 0 2,781 UP-Ceil-16CR-50 16.4 X 14 229.6 0.020 1.5 340 0.8 0 174 Subtotals for Structure: 5,447 0 3,118 Infil.: Win.: 10.4, Sum.: 30.9 274 3.048 834 1.594 700 436 Ductwork: 0 0 AED Excursion: 54 Room Totals: 6,281 700 3,608 II C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton, NY 12831 Page 2-5 Detailed Room Loads - Room 96 - Upstairs Master Bath (Peak Fenestration Gain Procedure) Room is in zone 2. which peaks at 2 pm Calculation Mode. Htg. & clg. Occurrences: 1 j Room Length: 13.0 ft. System Number: 1 j Room Width: 16.0 ft. Zone Number: 2 Area: 208.0 sq.ft. Supply Air: 54 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 1.7 AC/hr Volume. 1,872 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers- 1 Actual Winter Vent.: 9 CFM Runout Air 54 CFM Percent of Supply.: 16 % Runout Duct Size: 5 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 393 ft./min. Percent of Supply: 11 % Runout Air Velocity 393 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.128 in.wg./100 ft. Actual Summer Infil.: 29 CFM Area -U- Htg Sen _-—Clg Lat SenLL Description Quantity Value HTM Loss HTM _ _ Gain Gain N -Wall-12D1-Obw 16 X 9 125.6 0.076 5.6 706 0.8 0 95 W-Wall-12D1-Obw 13 X 9 117 0.076 5.6 658 0.8 0 89 N -GIs-1A-ry-o shgc-0.3 0%S 18.4 0.900 66.6 1,225 21.2 0 390 UP-Ceil-16CR-50 13 X 16 208 0.020 1.5 308 0.8 0 158 Subtotals for Structure: 2,897 0 732 Infil.: Win.: 9.9, Sum : 29.4 261 3.046 795 1 594 668 416 Ductwork: 0 0 AED Excursion: 18 Room Totals: 3,692 668 1,166 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM z ------ _._..__--- - _ - __ ._ __ - 9 Elite Software Development,Inc.'. Rhvac-Residential 8�Li ht Commercial HVAC Loads Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 26 - - -- ------ — Detailed Room Loads - Room 17 - Upstairs Stair/Hallway (Peak Fenestration Gain Procedure) General Room is in zone 2, which peaks at 2 pm Calculation Mode: Htg. &cig. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width 8.0 ft. Zone Number: 2 Area: 128.0 sq.ft. Supply Air: 47 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 1,152 cu.ft. Req Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 7 CFM Runout Air: 47 CFM Percent of Supply.: 15 % Runout Duct Size: 5 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 343 ft./min. Percent of Supply: 11 % Runout Air Velocity: 343 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.098 in.wg./100 ft. Actual Summer infil.: 8 CFM Area -U- Htg Sen ^Clg Lat Sen Description Quantity ValueHTM_ Loss HTM Gain Gain N -Wall-12D1-Obw$X 9 - 36 0.076____ _-- 5.6 202 __.0.8 0 27 N -GIs-1A-ry-o shgc-0.3 O%S 36 0.900 66.6 2,398 21.2 0 763 UP-Ceil-16CR-50 16 X 8 128 0.020 1.5 189 0.8 0 97 Subtotals for Structure: 2,789 0 887 InfiL: Win.: 2.7: Sum.: 8.1 72 3.042 219 1.597 184 115 Ductwork: 0 0 AED Excursion: 15 Room Totals: 3,008 184 1,017 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt -Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development Inc. Highland Home Heating&Cooling Witt-Stanhope Wilton. NY 12831 Page 27 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat CIg Sys No Name SF Btuh CFM Size Vel_ Btuh Stuh CFM CFM ' ---Zone 1--- 1 Family Room 289 7,492 105 1-6 807 3,445 870 158 158 2 First Floor Bath 96 2,492 35 1-5 241 716 512 33 33 3 Entry Foyer 96 1,141 16 1-5 115 341 205 16 16 4 Pantry 84 1,807 25 1-5 179 530 307 24 24 5 Kitchen 420 4,945 69 1-6 582 2,486 537 114 114 6 Master Bath 160 2,424 34 1-5 477 1,414 205 65 65 7 First Floor Master 180 5,805 81 1-6 727 3.102 691 143 143 Bedroom 8 Walk In Closet 72 613 9 1-5 54 160 154 7 7 9 Side Hall 64 2,462 34 1-5 253 749 512 34 34 10 Stair Landing Area 96 1,293 18 1-5 126 375 205 17 17 Zone 1 subtotal 1,557 30,474 425 13,318 4,198 613 613 ---Zone 2--- 11 Upstairs Front 176 5,111 71 1-5 630 1,868 622 86 86 Bedroom 12 Upstairs Bathroom 90 897 13 1-5 119 352 154 16 16 13 Upstairs Rear 156 4,377 61 1-6 543 2,318 576 107 107 Bedroom 14 Upstairs Master 154 1,307 18 1-5 178 527 253 24 24 Walk In Closet 15 Upstairs Master 230 6,281 88 2-5 609 3,608 700 166 166 Bedroom 16 Upstairs Master 208 3,692 52 1-5 393 1,166 668 54 54 Bath 17 Upstairs Stair/ 128 3,008 42 1-5 343 1,017 184 47 47 HallWay Zone 2 subtotal 1,142 24,673 344 10,857 3,157 499 499 Ventilation 10,216 1,795 2,882 Humidification 3,436 System 1 total 2,699 68,799 770 21,075 10,237 887 887 System 1 Main Trunk Size: 22x8 in. Velocity: 726 ft./min Loss per 100 ft.: 0.096 in.wg Note. Since the system is multizone. the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average Load Procedure + Excursion"method. Cooling System Summary Cooling Sensible/Latent Sensible T Latent Total' Tons Split Btuh Btuh Btuh Net Required: 2.61 67%/33% 21,075 10,237 31,313 Actual: 2.83 75%/25% 25,500 8,500 34,000 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model 59SC2C080S 17--16 24ABB336C"N30 Indoor Model: CNPV'3621AL' Brand. CARRIER CARRIER AIR CONDITIONING Description: Natural Gas or Propane Furnace Efficiency: 92.1 AFUE 14 SEER Sound: 0 0 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt- Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM Rhvac-Residential ii Light Commercal HVAC Loads P^ Elite Software Development,Inc., Highland Home Heating&Cooling Witt-Stanhope Wilton,NY 12831 Page 28 System 9 Room Load Summary (cont'd Equipment Data - Capacity: _ 75,000 Btuh -- 34,000 Btuh Sensible Capacity n/a 25.500 Btuh Latent Capacity: n/a 8,500 Btuh AHRI Reference No.: n/a 7854061 C:\Users\Joe\Documents\Elite Software\Rhvac 9 Projects\Witt-Stanhope.rh9 Tuesday, April 4, 2017, 3:48 PM VC,,- bO OO�b ZJ ` 1 WITT CONSTRUCTION, INC. 563 North Broadway SARATOGA SPRINGS, NEW YORK 12866 518.587.4113 518.587.0260 FAX www.wittconstruction.com 8/24/18 Town of Queensbury Attn:Building Dept To Whom It May Concern: This letter is to certify that at least 75%of the fixtures installed at 148 Sweet Rd,Queensbury,NY have high efficiency light bulbs installed in them. Please feel free to contact me if you have any further questions. Thank you, Ben Nathan NATIONAL AWARD WINNER CUSTOM HOME OF THE YEAR a • c u err Client Name: Witt Construction House Address: 148 Sweet Road,Queen sbury,NY No More Business As Usual Verifier Name/ID: Alex Pakatar BPI ID 5047587 NEBB BET 24163 Verifier Company The Pakatar Group,LLC,27 Cohoes Road,Watervliet,NY 1 Seneca ` rive Verifier Contact: (P)518-874-1604,(E)alex@thepakatargroup.com Avg€:='il'Park,NY 12018 (518)596 5586 Test Date: 16-Jul-18 Verifier Certifying Signature: By my signature above,I hereby certify the accuracy of the test results Date 7/16/18 Time 3:00 PM Climate Zone 2009 2012 2015 Temperature Indoor(F) 70 Zones 1&2 5 Outdoor(F) 93 Building Type Single Family Detache #of Stories I 2 7 3 Fan Model/SN Retrotec 5000 w/DM32 Manometer,SN:5FN100361 Zones 3 3 thru 8 Applicable Code: 2015 Climate Zone: 5 Conditioned Floor Area(ft2)per ANSI Z65: 5069 Building Volume(ft3) 48140 Envelope Target(CFM50) 2407 Envelope Test Results(CFM50)(AsrME779-10) 2246 Envelope Target(ACH50) 3 Envelope Test Results(ACH50) 2.80 wnwwwwwi�� _ — PASS NOTE: Envelope Passes if ACH50 is less than ACH 50 Target © Copyright 2017 The Pakatar Group,LLC,All Rights Reserved 00.5 New York State Residential Buildin. Ener. Standards Certificate This certificate is for projects with permits applied for after Jan.1,2008. 115 Southard Rd,Saratoga Springs,NY Protect Description Properly Address(Street.Town.ZIP Code) ❑ Single Family National Grid ❑ Multifamily Electric Utility serving this address ❑ Addition 11/2017 8/2018 ❑ Log Home Foundation Type ConsWctlon START Date Construction FINISH Date ❑ Basement 1 3,010 2 ❑ Slab on Grade *Units *Stones *Conditioned Sq.Ft. *Bedrooms ❑ Cnwl Space R-21 Basement/Crawl Space Walls _'Depth of Basement Insulation(ft) U-_Basemt Windows 0 NFRC 0 Default R--_Under Slab R- Floors over Unheated Spaces R__ Sloped Ceilings R-_Perimeter Slab Edge R-21 Above-Grade Walls R-43 Flat Ceilings U-_Windows 0 NFRC 0 Default U- Doors 0 NFRC 0 Default U-_Skylights 0 NFRC 0 Default Note:NFRC means the U-factor found on the manufacturer's label.Default values are used If the product is missing a manufacturer's label In this case,Default U-factor shall be determined In accordance with Table 102.1.3(1)of the 2007 NYS ECCC. Space Heating Fuel: ❑0i1 ❑Kerosene w LP Gas a Natural Gas 0 Wood n Electric 0 Heat Pump 0 Solar 0 Other Space Heating System: ❑Boiler /Furnace C Space Heater 0 Stove 0 Other ❑Electric Resistance ❑Heat Pump Primary Heating System Efficiency: 92 % 8 AFUE 0 HSPF Central Air Conditioning Efficiency: 13 % B SEER 0 COP ❑N/A Water Heating Fuel: 0 Oil o Kerosene Er LP Gas 0 Natural Gas 0 Wood a Electric Resistance 0 Heat Pump 0 Solar ❑Other Water Heating System: ¢Stand-Alone Tank 0 Indirect-Fired Tank ❑On Demand 0 Tankless Coil 0 Other Primary Hot Water System Efficiency: %Energy Factor Ventilation System: IR Exhaust ❑Supply 0 Balanced Ventilation Air Flow: % ❑Rated ❑Measured OTHER ENERGY FEATURES: Code-Compliance Method Used: 0 Software(see:w .energycodes.gov for New York RESCheck Version) 0 Noftwerechedt Maximum UA: YourUA_ ew ❑Worksheet(see:Department of State webste at www.dos.state.ny.us) 0 Home Energy Rating Redig Scan:__ ❑Book(see:Chapter 4 of the 2007 NYS ECCC) Rated by Note:For further instructions on Code Compliance Methods,see the Department of State Energy Code websee at www.doastate.ny.us/codelenergycodefovenriew.hlin.Compliance paths are codified In the 2007 NYS ECCC,Section 101.5. I certify to John and Patricia Healy (Owner)that the above information Is correct and that the premises listed HAVE been constrruuc`cttedin accordance with the NYS Energy Conservation Constructiion code. 43\4-1— T �Cay�STO vG�!a7y'� Signe Company Name Sig'I Lt113 . \t Print Name Phone Number Date I See 2007 NYS ECCC,Chapter 4 Section 401.3 for visibility and placement requirements for this certificate. obccx05-?c\-t christian a. augliera p.o. box 426 guilderland, NY, 12084 engineering 518.387.9480 4/17/2018 Ref: Stanhope Residence Country Club Drive Queensbury, NY 12804 Charles Dyer, Building Inspector Town of Queensbury Building Dept. 742 Bay Road Queensbury, NY 12804 This letter is to address your comments regarding the above mentioned residence. 1. Compliance to the 2015 International Energy Conservation Code and the 2016 supplement to the New York Energy Conservation Code shall be be demonstrated by the attached REScheck Compliance Certificate dated 4/17/2018. 2. It shall be deemed acceptable that the first floor deck is framed with 1-3/4"x 11-7/8"1.5E Timberstrand LSL's at 16"o.c. in lieu of 11-7/8"I-joists at 16"o.c. Should you need further information,you can contact my associates or myself during normal business hours at the above number. Regards, OF NE' Cl) ead-uroce_:„ Christian A. Augliera PE N.Y.S. License #090952 6 %F.ESstot'0 REScheck Software Version 4.6.5 if 0 Compliance Certificate 1 - A. 4 CO Project Stanhope Residence .,'� A, ' yips , ° y. �`` Energy Code: 2015 IECC . I. 4► Location: Glens Falls, New York Construction Type: Single-family ,, le 0.0961. e Project Type: New Conditioned Floor Area: 3,971 Constructiont2 N ,E;'-'6 ,� Glazing Area 16% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Country Club Drive Witt Construction,Inc. Queensbury,NY 12804 563 North Broadway Saratoga Springs,NY 12866 • ompliance: Passes using UA trade-off Compliance: 1.4%Better Then Code Maximum UA: 438 Your UA: 432 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Basement-Unfinished:Solid Concrete or Masonry 915 0.0 15.0 0.046 41 Wall height:7.5' Depth below grade:6.8' Insulation depth:7.5' Pella 250 Slider.Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.270 4 Basement-Stair Area:Solid Concrete or Masonry 133 0.0 15.0 0.046 6 Wail height:7.5' Depth below grade:6.8' Insulation depth:7.5' Basement-Finished:Solid Concrete or Masonry 67 21.0 0.0 0.043 3 Wall height:7.5' Depth below grade:6.8' Insulation depth:7.5' Basement @ Low Grade-Finished:Solid Concrete or Masonry 461 21.0 0.0 0.052 22 Wail height:7.5' Depth below grade:3.5' Insulation depth:7.5' Pella 250 Slider:Vinyl/Fiberglass Frame:Double Pane with Low-E 45 0.270 12 1st Floor Walls:Wood Frame,16"o.c. 2,071 21.0 0.0 0.057 100 Pella 250 Awning:Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0.270 2 Pella 250 Case:Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.260 16 Pella 250 DH:Vinyl/Fiberglass Frame:Double Pane with Low-E 85 0.270 23 Pella 250 Fixed:Vinyl/Fiberglass Frame:Double Pane with Low-E 71 0.260 18 Project Title:Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\erg data\Stanhope-Energy Page 1 of10 Calc.rck Assembl Gross Area Cavity Cont Y or R-Value R-Value U-Factor UA Perimeter Pella 250 Transom:Vinyl/Fiberglass Frame:Double Pane with low-E 17 0.270 5 Entry Door:Solid 20 0.350 7 Fire Door:Solid 20 0.350 7 Pella Entry Door:Glass 43 0.300 13 Kitchen/Dining bumpout:Flat Ceiling or Scissor Truss 23 38.0 0.0 0.030 1 Master Suite Area roof:Raised or Energy Truss 558 49.0 0.0 0.020 11 2nd Floor Walls:Wood Frame, 16"o.c. 1,279 21.0 0.0 0.057 62 Pella 250 Awning:Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0.270 2 Pella 250 DH:Vinyl/Fiberglass Frame:Double Pane with Low-E 185 0.270 50 2nd Floor Truss Ceiling:Raised or Energy Truss 1,182 49.0 0.0 0.020 24 2nd Floor Flat Ceiling:Raised or Energy Truss 16 38.0 0.0 0.025 0 2nd Floor Cloped Ceiling:Raised or Energy Truss 101 38.0 0.0 0.025 3 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory require liste t check Inspection Checklist. f p i a+-, A A4ry ii e, ca , E - �-� 4 1r 7i I Na e-Title 3 nature Date Project Title: Stanhope Residence Report date: 04/17/18 Data filename:2:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 2 of10 Calc.rck 0 REScheck Softwareection VersionChecklist 4.6.5 ve p Energy Code: 2015 IECC Requirements: 0.0%were addressed directly in the REScheck software Text in the"Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. Section ! ' Plans Verified Field Verified # ; Pre-inspection/Plan Review i Value Value Complies? Comments/Assumptions & Req.iD! _ t 103.1, Construction drawings and OComplies 1103.2 documentation demonstrate ODoes Not i(PR1]1 energy code compliance for the :Not Observable iii, building envelope.Thermal envelope represented on ONot Applicable construction documents. 1103.1. Construction drawings and OComplies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ONot Observable [PR3]1 lighting and mechanical systems. 44. Systems serving multiple ONot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. __- 302.1. Heating and cooling equipment is Heating: Heating: OComplies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ONot Observable Manual j or other methods Btu/hr Btu/hr approved by the code official. ONot Applicable 1 Additional Comments/Assumptions: 1 i High Impact(Tier 1) 2 Medium Impact(Tier 2) _: 3 Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 3 of10 Calc.rck I Section ! i Plans Verified Field Verified t ID; Foundation Inspection Value Value ; Complies? r Comments/Assumptions 1&Re9•402.1.1 Conditioned basement wall R- R- OComplies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R. R- ODoes Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection.Not ONot Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall OComplies (F0511 insulation installed per ODoes Not manufacturers instructions. ONot Observable —ONot Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies —See the Envelope Assemblies- fF06)1 Insulation depth of burial or ODoes Not table for values. distance from top of wall. ONot Observable ONot Applicable 303.2.1 A protective covering is installed ❑Complies (F011]2 to protect exposed exterior ❑Does Not 14, insulation and extends a :Not Observable minimum of 6 in.below grade. :Not Applicable 403.9 Snow-and ice-melting system OComplies [F0142 controls installed. ODoes Not ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 4 of10 Caic.rck Section1 i # !Framing/Rough.in Inspection z Plans Verified 3 Field Verified Complies? 1 Comments/Assumptions &Req,ID; Value t Value 402.1.1, Door U-factor. U- U- QComplies See the Envelope Assemblies 402.3.4 ODoes Not table for values. (FRl]1 ONot Observable 17 ONot Applicable 402.1.1, Glazing U-factor(area-weighted U_ U OComplies See the Envelope Assemblies 402.3.1, average). ODoes Not table for values. 1402.3.3, 402.5 ONot Observable 4(FR2]i ONot Applicable 1303.1.3 U-factors of fenestration products °Complies i �� __^�� I[FR4]i are determined in accordance ODoes Not with the NFRC test procedure or taken from the default table. ❑Not Observable ONot Applicable 402.4.1.1 Air barrier and thermal barrier OComplies [FR23)1 installed per manufacturer's °Does Not instructions. ONot Observable ONot Applicable 402.4.3 Fenestration that is not site built ❑Complies 1[FR20]1 is listed and labeled as meeting ODoes Not ( AAMA/WDMA/CSA 101/1.S.2/A440 or has infiltration rates per NFRC ❑Nat Observable 400 that do not exceed code ONot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures OComplies [FR16]2 sealed at housing/interior finish ODoes Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ONot Observable ONot Applicable 403.3.1 Supply and return ducts in attics ❑Complies __ [FR12]1 insulated>-R-8 where duct is ODoes Not foi. >-3 inches in diameter and>_ ONot Observable R-6 where<3 inches.Supply and return ducts in other portions of ONot Applicable the building insulated>=R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies 1FR1S]3 ducts or plenums. ODoes Not _ ONot Observable ► ONot Applicable 403.4 HVAC piping conveying fluids R R- OComplies [FR17P above 105 QF or chilled fluids ODoes Not below 55 QF are insulated to a:R- ONot Observable ONot Applicable !403.4.1 Protection of insulation on HVAC 0Complies [FR24]1 piping. ODoes Not ONot Observable ONot Applicable 403.5.3 Hot water pipes are insulated to R- R- QComplies [FR1812 ZR-3. ODoes Not ONot Observable ONot Applicable 403.6 Automatic or gravity dampers are _ OComplies [FR19]2 installed on all outdoor air ODoes Not intakes and exhausts. ONot Observable ONot Applicable 1;High Impact(Tier 1) 2 Medium impact(Tier 2) 1 3 !Low Impact(Tier 3) Project Title:Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client ProjectsWitt\Stanhope Residenceksource\eng data\Stanhope-Energy Page 5 of10 Calc.rck Additional Comments/Assumptions: 1=High impact(Tier 1) H 2 i Medium Impact(Tier 2) 3 =Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 6 of10 Calc.rck 4- } Section i Plans Verified Field Verified 1 • # ; Insulation Inspection Complies? Comments/Assumptions &Req.iD I Value Value I 303.1 All installed insulation is labeled ❑Complies (1N13j2 or the installed R-values ❑Does Not provided. ONot Observable ONot Applicable 1402.1.1. Wall insulation R-value.If this Is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least of the ❑ Wood ❑ Wood ❑Does Not table for values. i 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ONot Observable (IN31} exterior,the exterior insulation 0 Steel 0 Steel ❑Not A licable kv, requirement applies(FR10). pp 303.2 Wall insulation Is installed per ❑Complies (IN4j1 manufacturer's Instructions. ❑Does Not ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 1 2 i Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 7 of10 Calc.rck i Section 1 Plans Verified ' Field Verified I -1&Re ,id i Final Inspection Provisions # Value Value 1 Complies? ' Comments/Assumptions q 1402.1.1, Ceiling insulation R-value. R. R. ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood Oboes Not table for values. 1402.2.2, 1402.2.E 0 Steel 0 Steel ONot Observable ![Fil]1 ONot Applicable 1 303.1.1.1, Ceiling insulation installed per OComplies 303.2 manufacturer's instructions. Oboes Not [F12]1 Blown insulation marked every 300 ft2. ['Not Observable ONot Applicable 402.2.3 Vented attics with air permeable ❑Complies i[F122]2 insulation include baffle adjacent Oboes Not 1 to soffit and cave vents that extends over insulation. ONot Observable ONot Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies _ { [F13]1 insulation ER-value of the Oboes Not adjacent assembly. ONot Observable ONot Applicable 402.4.1.2 Blower door test @ 50 Pa.<=5 v ACH 50= ACH 50= ❑Complies l(F117]1 ach in Climate Zones 1-2,and Oboes Not <=3 ach in Climate Zones 3-8.i ONot Observable ONot Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 OComplies [F14]1 cfm/100 ft2 across the system or ft2 Oboes Not <=3 cfm/100 ft2 without air ONot Observable handler @ 25 Pa.For rough-in 6 tests,verification may need to ONot Applicable 1 occur during Framing inspection. j 403.3.3 Ducts are pressure tested to cfm/100 dm/100 ❑Complies [F127]1 determine air leakage with ft2 ft0 Oboes Not either:Rough-in test:Total ONot Observable leakage measured with a ONot pressure differential of 0.1 inchApplicable w.g.across the system including f the manufacturer's air handler I enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air i handler enclosure. 403.3.2.1 Air handler leakage designated OComplies [FI24]1 by manufacturer at<=2%of Oboes Not design air flow. i ONot Observable ONot Applicable _� 403.11 Programmable thermostats OComplies (F19]2 installed for control of primary Oboes Not heating and cooling systems and ONot Observable initially set by manufacturer to ONot code specifications. Applicable 403.1.2 Heat pump thermostat installed OComplies _ f [F110]2 on heat pumps. Oboes Not 1 ONot Observable ONot Applicable 403.5.1 Circulating service hot water ' ❑Complies [Fill? systems have automatic or Oboes Not accessible manual controls. ONot Observable ONot Applicable i 1 High impact(Tier 1) 2 'Medium Impact(Tier 2) r 3 1 Low Impact(Tier 3) Project Title:Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 8 of10 Calc.rck 7 Section Plans Verified ! Field Verified # Final Inspection Provisions =, Complies? Comments/Assumptions &Req.1D p Value Value 1 ? 403.6.1 All mechanical ventilation system OComplies (F125)2 fans not part of tested and listed ODoes Not HVAC equipment meet efficacy ONot Observable and air flow limits. vY�_' ONot Applicable 403.2 Hot water boilers supplying heat OComplies [F126)2 through one-or two-pipe heating ODoes Not systems have outdoor setback ONot Observable control to lower boiler water temperature based on outdoor ONot Applicable temperature. 403.5.1.1 Heated water circulation systems OComplies [F128]2 have a circulation pump.The ODoes Not system return pipe is a dedicated ONot Observable return pipe or a cold water supply ONot Applicable pipe.Gravity and thermos- syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems OComplies [F12912 comply with IEEE 515.1 or UL ODoes Not 515.Controls automatically ONot Observable adjust the energy input to the ' heat tracing to maintain the ONot Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [Fi30}2 have recirculation pumps that ODoes Not pump water from a heated water ONot Observable supply pipe back to the heated ONot Applicable water source through a cold ► water supply pipe have a demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1040F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ODoes Not B55.1.Potable water-side ONot Observable pressure loss of drain water heat recovery units<3 psi for ONot Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F1611 fixtures or 75%of permanent ODoes Not fixtures have high efficacy lamps. ONot Observable Does not apply to low-voltage f lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have OComplies [F123Is no continuous pilot light. ODoes Not ❑Not Observable ONot Applicable (1 High Impact(Tier 1) 2 j Medium Impact(Tier 2) I 3 ?Low Impact(Tier 3) Project Title:Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 9 of10 Calc.rck Section i iPlans Verified Field Verified ' # 1 Final Inspection Provisions Complies? Comments/Assumptions C�Com lies &Req.ID j Value Value 401.3 Compliance certificate posted, T (Fl�)2 ❑Does Not ONot Observable ONot Applicable 303.3 Manufacturer manuals for OComplies (F118)1 mechanical and water heating ODoes Not systems have been provided. ONot Observable ONot Applicable Additional Comments/Assumptions: P1 IHigh Impact(Tier 1) i 2 1Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) Project Title: Stanhope Residence Report date: 04/17/18 Data filename:Z:\Current Client Projects\Witt\Stanhope Residence\source\eng data\Stanhope-Energy Page 10 of10 Calc.rck 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above•Grade Wall 21.00 Below•Grade Wall 15.00 Floor 0.00 Ceiling/Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.27 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments