BINS-000932-2019 02142019INSPECTION WORKSHEET (BINS-000932-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0072-2018 Case Module:Permit Inspection Date:Thu Feb 14, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Insulation Job Address:Parcel Number:119 SEELYE RD Queensbury, NY 12804 227.17-1-49 Contact Type Company Name Name Granted Permission Giordano, Victoria Architect Dybas, Curtis Primary Owner Giordano, Victoria Applicant Giordano, Ken Engineer Environmental Design Partnership, LLC Granted Permission Giordano, Ken Primary Owner Giordano, Ken Checklist Item Passed Comments Building Inspector Notes NO 2/14/19 Insulation Not Approved Remaining Items: - Provide an updated REScheck for spray foam insulation. - Seal all narrow stud bays or cracks between studs, around receptacles and switches, ductwork and at the top and bottom plates where foam is missing. - Install Roxul Rock wool insulation equal to the ceiling R value with a vapor barrier at fireplace chimney 2nd floor. - Basement Insulation not done. - Provide certified field report from foam insulation contractor listing type of foam, R Values and thickness for ceilings, walls and box sill areas. - Accessible areas larger than 32 sf will need intumescent coating applied to foam insulation not covered by 1/2" sheetrock. Feb 14, 2019 Page (1) INSPECTION WORKSHEET (BINS-000932-2019) Checklist Item Passed Comments Window Sealing NO U Factors = .3 cfm for windows, .5 cfm for doors NO Tyvek or Similar Exterior Sealant NO Proper Vent, Attic Vent NO Insulation Residential Check Commercial Check NO 2/14/19 Insulation Not Approved Remaining Items: - Provide an updated REScheck for spray foam insulation. - Seal all narrow stud bays or cracks between studs, around receptacles and switches, ductwork and at the top and bottom plates where foam is missing. - Install Roxul Rock wool insulation equal to the ceiling R value with a vapor barrier at fireplace chimney 2nd floor. - Basement Insulation not done. - Provide certified field report from foam insulation contractor listing type of foam, R Values and thickness for ceilings, walls and box sill areas. - Accessible areas larger than 32 sf will need intumescent coating applied to foam insulation not covered by 1/2" sheetrock. Blower Door Test NO Combustion Air Supply for Furnace NO Fresh air supply 3' from grade NO Duct Insulation - if required in unheated spaces NO Door / Window Sealed (No Insulation)NO Tub Shower R-20 with Vapor Barrier NO Feb 14, 2019 Page (2) INSPECTION WORKSHEET (BINS-000932-2019) Checklist Item Passed Comments Air Barrier behind Knee Walls NO All Ductwork Sealed Return and Supply NO Duct Blaster Test for duct work, R-8 NO All Return Air Hard Duct Work NO House Wrap Taped at all Seams NO Feb 14, 2019 Page (3) O'Brien, John (Inspector)