SOLAR-0447-2018TOWN OF QUEENSBURY
742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: SOLAR-0447-2018 Date Issued: Friday, February 8, 2019
This is to certify that work requested to be done as shown by Permit Number
has been completed.
SOLAR-0447-2018
Tax Map Number:
Location:
Owner:
266.3-1-2
823 State Rte 149
WESLEY BISHOP
Applicant:Apex Solar Power
This structure may be occupied as a: Solar Panel Installation
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the
Planning Board or Zoning Board of Appeals.
Director of Building & Code Enforcement
TOWN OF QUEENSBURY
i, 'i 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
s 4
.�:.-, Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: SOLAR-0447-2018
Tax Map No: 266.3-1-2
Permission is hereby granted to: Apex Solar Power
For property located at: 823 State Rte 149
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: WESLEY BISHOP Solar Panel-Residential $23,850.00
Owner Address: 823 State Route 149 Total Value $23,850.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Apex Solar Power
64 MAIN ST
Queensbury,NY 12804
Plans&Specifications
Solar Panel Installation
$ 75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday,July 12,2019
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o, +uee r•.ury; / Thur, . y,t'ul _ ,2018
SIGNED BY: { for the Town of Queensbury.
Director of Building&Code Enforcement
Office Use Only
+ JUL JO2J018
,• L Permit#: s L- Q- - O691-• 2'0(P.)
=► - TOWN OF QUEENSBURY Fee:$ 1-5.00
BUILDING&CODES
742 Bay Road,Queensbury,NY 12804 Invoice#: 0(p I\'R
P:518-761-8256 www.queensbury.net
SOLAR PANEL PERMIT APPLICATION
• Property Owner(s):
Name(s): Ueste Bicko f
Mailing Address, C/S/Z: g2.3 S4-0,4e R,o,.A-k 11.49% Lc (.e r e JV 'ISMS"
Cell Phone:_( siic ) -ros® Land Line:_(
Email: w bi sh road rune era cool
Project Address: same as aIIOJ..
Section Block Lot: 1. ,t -1-2.
Existing Use: rid Single Family ❑ 2-4 Family ❑ Commercial ❑ Other:
• Solar Contractor:
Business Name: CQ?ex Solar Pope'
Contact Name: Cochi 14irr,elrl0K
Mailing Address, C/S/Z: Macro 'eel-,G1ueenc Ll N4 moll
Cell Phone:_( ) Land Line:_( gig ) 3aq-27rsb
Email: ChimetricKg apex rowereMary
• Electrical Contractor:
Business Name: hPina -ce €tec4rk.. C 16A apex Saar foaaer'
Contact Name:
Mailing Address, C/S/Z:
Cell Phone:_( ) _ Land Line:_( )
Email:.
Contact Person for Building & Code Compliance:
Cell Phone: ( ) Land Line: ( )
Email:
Solar Panel Application Revised December 2017
I` • ;{ t1
Estimated cost of construction: $ 3� cSa.00
Total System Capacity Rating (sum of all panels):
Solar PV System: q kW DC
Select System Configuration: *Please See a ? ° Ste.
❑ Supply side connection with micro inverters
❑ Supply side connection with DC optimizers _• - _
❑ Supply side connection with string inverter • _
❑ Load side connection with DC optimizers
❑ Load side connection with micro inverters
❑ Load side connection with string inverter
Please sign below to affirm that all answers are correct and that you have met all the
conditions and requirements to submit a unified solar permit.-
1e .se see CA ( Je2 ,roX.c.4 fors ,
Homeowner's Signature • Date
Coera+ 1*pax Sofa Pourer 1f S;2 I3
Solar Co. Representative Signature Date
Solar Panel Application Revised December 2017
. .-
,..
PHOTOVOLTAIC SYSTEM EQUIPMENT'
V.,
, 'D ecEilviin
SYSTEM SIZE:
DC/AC kW STC: 9kW 1 7,6kW JUL 1 0 2018 1 Ul PV MODULES:
INVERTER(S): (30)TRINA TSM3OODDO5A.05(11)
(1)SE7600H-US
ii U i SCOPE OF WORK:
NMI INSTALLATION OF A SAFE AND CODE-COMPLIANT
TIM TOWN OF CARENSBEURY GRID-TIED SOLAR PV SYSTEM.
ell L2t.P.L.DiMG 114 CODS
MI
.111
%
FILE COPY
11111
Iwo
1111101111
111111111111 TOWN OF C)UEENSBURY r 7a,,s A. C
1. al BUILDiNG DEPARTMENT
, i.lased on our limited examinaiion,compiiance
il: ,,,1t74 LI
wnh our comments she'l',:.ct be construed as go
indicating the Oans and specifications are in d,,,, ...Al*. ...
fuil compliance with the Sukg Codes of `0,,,, 08426B )
Now York State. s NO ,
POST INSTALL SIJNEYE I.1 E El 1.5Zi
,
266.3-1-2 SOLAR-0447-2018 TowN oF :- • - - -
,.... 6,OP
i -
BUILDING & c\ir.',,o• ,- 0- . , APPUCABLE COD
2015 IRC CODE I
2015 NYS BUILDING CODE
if404'
Bishop, Wesley 2015 NYS RESIDENTIAL CODE
Reviewed By.--.4,Ari4 i/ 2015 NYS PLUMBING CODE
823 State Rte 149 2015 NYS MECHANICAL CODE
Solar Panel Installation , ,iiiii,7 44 ,,
Datr.. ______ 'fil' ._ 2014 NATIONAL ELECTRICAL CODE
SHEET INDEX
, PV-01 COVER AND PLOT PLAN
PV-02 SITE PLAN,STRINGS,BOM
PV-03 MODULE LAYOUT
A 49 PV-04 THREE-LINE DIAGRAM
1 1/4.444 0 _
1 SITE PLAN
1 SCALE: MTS.
I
1
1 •
1 PROJECT NA114E
. • . REVISION NOTES: DRAWN
DATE 'CLIENT: i SCALE
• t, • 64 Main Sirtel REV REV BY DATE DESCRIPTION BY: I BISHOP 420447 ii 86231SHSOTPA,TEWERSOLEYinE 149 I
• a eh* ,• ueensbuly,NY 12804
..: t..a ex , 1.1 --1", , RGR 5/25/16 ROOF MOUNT
1
DRAWINGNUMBR:
•***tie*, Ell MIMI I CHECK DATE' 9000 WATTS OUEENSBURY,NY 12804
. t . Solar Power salcs@apexsolatpowcr.cora
(518)-309-2786 III.MIIIIIIIIIIMIIMIIIIIIIIIIIIII BY
1518-798-1571
f 1.11.111 DRAWING TITLE:COVER AND PLOT PLAN siPEROsEP:E SI R 6 DI C:
_m I
KEY:
----- PROPERTY LINE ®SUBPANEL
--- CONDUIT RUN Ej DC DISCONNECT
DRIVEWAY ®AC DISCONNECT
n SOLAR MODULE
Q MAIN SERVICE PANEL®®UNCTION Box
E UTILITY I MONITORING UNIT
El PM METER C7�.COMBINER BOX
Q ROOF OBSTRUCTION
CUSTOMER INITIALS:
STRING 1
G. '�4 1$MODULES
INVERTER 1
INPUT 1
V-iii5e-ii, ,
r
. g A. 044y0,1.
*i\y 1 « •
•^ I! rc
z
�(1� a
o. 084285
9OPEsstO
MAIN SERVICE PANEL
STRING 1
10 MODULES J
INVERTER 1 UTILITY METER
INPUT 1 --'"""'f—
— AC DISCONNECT
AC DISCONNECT
0
INVERTER
NOTES:
1. BOO TO BE LOCATED INTERNALLY ON EASTERN SITE PLAN DETAIL
BASEMENT WALL NEXT TO EXISTING MOP
2. CONDUIT SHOULD BE RUN PARALLEL TO EXISTING STRING 2 SCALE: N.T.S.
WHENEVER POSSIBLE. 12 MODULES
INVERTER I
INPUT 2
• REVISION NOTES: 1 DRAWN PROJECT NAME: CLIENT: SCALE:
.e ! a. 64 Ma Street REV REV BY DATE DESCRIPTION I BY: DATE. BISHOP-420447 BISHOP,WESLEY
`s � `�kRs 3( Queensbmy,NY1280-0 1
*
,l tea...a e RGR 5125118 (ROOF MOUNT 823 STATE ROUTE 149
CHECK '�—}9000 WATTS QUEENSBURY,NY 12804 DRAWING
DATE:
���`�.� ` mlcs@apexsulmpown.cam BY: 5184984571 NUMBER: r.
r (5I8)-999-2786 DRAWING TITLE: SITE PLAN,BOM,NOTES PV 02 1
M
, I:
ROOF SPECS
RAFTER SIZE: 2X6
/ g,_g2• �r 32'-92' �` 3 82"`A RAFTER SPACING(in): 16
ROOF MATERIAL: ASPHALT
.ale 33'-31" A
ARRAY SPECS
TILT(°): 27
SIN
iv AZIMUTH(a): 93
, - 1 -- J SQUARE FEET(ft2) 315
\ ___ _ _- ____:_i_j=ji____LL.,_ ___ _ _, ___ _ — _- _ .-_,__ -__- .__ _,._ -__ i.
Q I II 0 CEO 0 0' : ±;
o In
• s A. C .i'�0,›
' f\I\
:t A
tp a
at
_ �� �p 084266
�FESS10 •
. / 26'-Ba"
• 2
OMOUNTING DETAIL
SCALE: NTS
()ARRAY LAYOUT - ROOF 1
AZIMUTH: SCALE: NTS Solar Modul
IronRidge XR-100 Rail
L-Foot
Flashing-Low Profit
Composite Shingl
5/16"LAG
(Minimum 2.5"thread penetration)
• REVISION NOTES: DRAWN PROJECT NAME: `CLIENT: 'SCALE:
•• R 64 Main Strcet REV REV BY DATE DESCRIPTION
BY: DATE. BISHOP-420447 BISHOP,WESLEY
• !d 0:re Quecnsbury,NY 12804 RGR 5/25/18 ROOF MOUNT 823 STATE ROUTE 149
I.•. 4.••a ex CHECK 9000 WATTS QUEENSBURY,NY 12804 DRAWING
•'% ilfy,• - BY: DATE: 518-798-1571 NUMBER:
•
Solar Power snlesla.(5181.389-2706r.cnm
�' a (518)-309-2786 DRAWING TITLE: — —
3 ,
P
y33Nltj 1
a
O y2
�� .•.�!- !� PAN N0 CC) O d i-
W V e 't 0 12 3 Y�Ny
�,et Q¢ Z O Cn w0 co
1111111.1
tLLI
z,a O 4 3ZQ s o $aD
y mK 6C
14t. to
\111-'
z
N
/ W
O
Vro
0 , ,,1
-*
0,r,,.a.
m� I U
k. N
y
0.0w,
�� 0, Q
Olk `vAI%.01 pry t.
0111RatOWn011ag•
adt, °451 MS
IIV,,,,,W0' WWI
z.
00 laimpv. � �7 ov N y
pp e
N N
9 vs
00Øww
0111141)
)(or,
00101)
10 er,T,:,...'''''' --
0
015/
0
•tied.
r r
i,
. 1
INVERTER LABELS-ONE FOR EACH INPUT PHOTOVOLTAIC AC DISCONNECT MODULE ELECTRICAL SPECIFICATIONS INVERTER SPECIFICATIONS DESIGN CONDITIONS ELECTRICAL KEY: }
ALL SOLAREDGE INPUTS MAXIMUM AC OPERATING CURRENT 32A (30)TRINATSM3000005A.05(11) SOLAREDGE 8E760014)S HIGHEST 2%DB DESIGN TEMP(°C): 31 -1M_ BREAKER '
Vapp=350V NOMINAL OPERATING AC VOLTAGE 240V SHORT CIRCUIT CURRENT(Isc): 9.64 RATED WATTS(EACH): 7600 MIN.MEAN EXTREME ANNUAL DB(*C): -29 -I.- SWITCH
f Vmax=500V OPEN CIRCUIT VOLTAGE(Vac): 39.9 AC OPERATING VOLTAGE(V); 240 0 SCREW TERMINAL
INPUTS WITH NO STRING COMBINATIONS OPERATING CURRENT(IMP): 9,19 AC OPERATING CURRENT(A): 32 CS2 FUSE
III SPLICE
'topp=8.5A OPERATING VOLTAGE(VMP): 32.6 NUMBER OF MPPT CHANNELS 2 'a° EARTH GROUND
Isc=11.25A INVERTER EFFICIENCY: .99 ?7 CHASSIS GROUND
INPUTS WITH(2)STRING COMBINATIONS INTEGRATED DC DISCONNECT -—-GEC
lopp=17A EGO
Isc=22.5A
(4)#10 PV-Wire (3)#6 THHN
(4}#10 THHN (1)#6 THHN GRD (3)#6 THHN (3)#4 THHN AI
(2)#6 BARE GRD (1)#6 THHN GRD 3/4"EMT (1)#6 THHN GRD (1)#6 THHN GRD
FREE AIR 3/4"EMT 3/4"EMT 1"EMT
NEMA 3R UL LISTED METER
SOLADECK BOX SOLAREDGE SE7600H-US AC DISCONNECT \ 2
ON ROOF INVERTER WITH INTEGRATED AC DISCONNECT 60AMP SERVICE
DC DISCONNECTS 60AMP SERVICE RATED FUSABLE
L0 1 STRING OF Q L 1 RATED NON-FUSIBLE (2)-40A FUSES
78 MODULES L_..._ __._ ()INPUT 1 PIERCING TAPS
OUTPUT.d - -r— "�
r - m `R 6EO LOAD 49 LINE LOAD T. LINE ---5__ 200AMSP
f�1 _ J
L'O 1 STRING OF T L U -L__. _ `- INPUT2 -- ---- 240V
12 MODULES I DC
m . Eck„-..._.-_200A MAIN BREAKER
ALL MODULES EQUIPPED
WITH SOLAREDGE CELLULAR
P320 OPTIMIZERS COMM.KIT E)LOADS
____r1 {
(E)LOADS
GEC IRREVERSIBLY SPLICED
TO EXISTING GEC OR BONDED
_ DIRECTLY TO EXISTING
GROUNDING ELECTRODE
I
CONDUIT ELEVATION:1/2 TO 3-1/2"=22°C
HIGH AMBIENT TEMPERATURE:31°C
200 x 1.2=240 EXTREME LOW:-29°C
240-200(MCB)=40A SOLAREDGE SE7500H-US MAX CURRENT=32A ROOFTOP AMBIENT TEMP:53°C=0.76
MAX ALLOWABLE AC PV BREAKER=40A MAX DESIGN CURRENT=32A X 1.25=40A=40A BREAKER/FUSES CONDUIT FILL:1
I' 6461aia StreetREVISION NOTES: I DRAWN DATE: PROTECT NAME: CLIENT: SCALE:
Qaesnsbmy,NY 12694 REV REV BY DATE DESCRIPTION I BY: BISHOP-420447 BISHOP,WESLEY
1 6660 Joy Road RGR 5/26/18 ROOF MOUNT 823 STATE ROUTE 149
Ms.\orem2ogl°0"wWFnCAONpe[S°MVmxnrHamws11.909 tan Syracuse,NY 13057 CHI` DATE: 9000 WATTS OUEENSBURY,NY 12804 DRAWING
1 HY: 516-798-1571 NUMBER:
I saksl4apexsotaspowercom
(510300-2786 DRAWING TITLE:THREE-LINE DIAGRAM Pa604 i
I `
1
I
I
I
-
. . ..t ° 1' W 46 if, 0 is �2.,, w C
I r
UL 10 2010 C10
solar' - . ! :. � �� ,. �,
TOWN OF EENZ,,BUR CC
i _ . BIy( - a(Q3G&CODES LU
SolarEdge Single Phase Inverters [c
For North America LIJ
SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US I
SE7600A-US/SE10000A-US I SE11400A-US Z
to 4._ --- s . „.., _, ' . ' -`r
c } .# - - ,t' r (+ei lam,e :fr
s * i` KJf 1 rt a L' • fcl' * F -i/
ii
* t j A2 .mac l •
:ter: 1. i•` , yla ?9, a � ,q .'IR`• v, -
- ♦ :-, .4L."ek. f r,. 1 - — ..fir J�laal,* • ,7'1*'11`j�s .�11 -
�r may
''...... ,3
a 'q' n 1 r .tca' ,��..Y�
I
1.. 't
• ?
. 'A ~y Y I;
_ 1 I� -
p 4
The best choice for SolarEdge enabled systems
j Integrated arc fault protection for NEC 2011 690,11 compliance •
Rapid shutdown for NEC 2014 690,12 -
- r Superior efficiency(98%) _ '
-K Small,lightweight and easy to install on provided bracket • - •
` Built-in module-level monitoring
�' Internet connection through Ethernet or Wireless .- - . _ . - — - - -
Outdoor and indoor installation " . • -
Axed voltage inverter,DC/AC conversion only _
s Pre-assembled Safety Switch for faster installation
E
Optional—revenue grade data,ANSI C12.1.
' USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-UK=ISRAEL ' www,solaredge,us f
s
‘ ? t
solar -. I g ./...-yi Single Phase Inverters for North America
SE3000A-US/SE3800A-US I SE5000A-US I SE6000A-US/
SE7600A-US I SE10000A-US/SE11400A-US
faitMI‘77.1S SE3800A-US, SES000A-USiSE6000A-US L SE7600A-US 1 SE10000A-US I SE11400/2rUSI
OUTPUT
9980 @ 208V
Nominal AC Power Output 3000 ---r 3800 5000 6000 7600 11400 VA
10000 e24OV
540 @ 10800 @
Max.AC Power Output 3300 4150 00 @240V208V @240V208V 6000 8350 12000 VA
545 10950
AC Output Voltage tvlin.-Nom.-isilaxPl
- . s/ . - 1 -
183-208-229 Vac
AC Output Voltage Min.-Nom.-Max.'l
./
211-240-264 Vac
AC Frequency Min.-Nom..-Max.' 59.3-60-60.5 Hz
• 1 24 @ 208V 1 I 48 @ 208V
Max.Continuous Output Current 12.5 16 25 1 32 47.5 A
21 @ 240V 42 e 240V
GFDI Threshold 1 A
Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes
[WPM'
Maximum DC PowerfSTC) 4050 I 5100 I 6750 I 8100 I 10250 1 13500 I 15350 W
Transformer-less,Ungrounded Yes
Max.Input Voltage 500 Vdc
Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc
Max.Input Current 9.5 1 13 1 16.5 @ 208V I 33 @ 208V I
M18 1 23 30.5 e 240V 34.5 Adc
15.5 e 240V
Max.Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600ko Sensitivity
,
Maximum Inverter Efficiency 97.7 98.2 1 98.3 98,3 98 98 98 %
97 @ 208V 97 @ 208V
CEC Weighted Efficiency 97.5 98 97.5 97.5
98 @ 240V 97.5 e 240V
Nighttime Power Consumption <2.5 <4 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional)
Revenue Grade Data,ANSI C12.1 Optionalm
Rapid Shutdown-NEC 2014 690.12 Yes
'STANDARD COMPLIANCE -
Safety 1111741,111.16996,UL1998,CSA 22.2 .
Grid Connection Standards . 1E6E1547
Emissions FCC part15 class B
"INSTALLATIODKVSFICIFICATWIS
AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG
DC input conduit size/#of strings/ 3/4"minimum/1-3 strings/
3/4"minimum/1-2 strings/16-6 AWG
AWG range 14-6 AWG
Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/
30.5 x 12.5 x 7.2/775 x 315 x 384
(HxWxD) 775 x 315 x 260 mm
Weight with Safety Switch 51.2/23.2 1 54.7/24.7 88.4/401 lb/kg
Natural
convection
Cooling Natural Convection and internal Fans(user replaceable)
fan(user
replaceable)
Noise <25 <50 dBA
Min.-Max.Operating Temperature
-13 to+140/-25 to 160 1-40 to+60 version availablem) 'F/*C
Range
Protection Rating NEMA 3R
10 For other regional settings please contact SolarEdge support.
OA higher current source maybe used;the inverter v.ulllimit as input current to the values stated.
Olfievenue grade inverter P/N:StxxxxkUSOOCINNR2 lfor 76001N onyerter:S67600A.US002NNR2).
lq-40 version P/N:SEsxxxA•USOOONNU4(for 7600W inverter:567600A•US002NNNO.
. .
r :._
, ..
. . .
GI Lict-As.
,,,t„,,.-',, ,-,Ir., ',M11:11:HOW,' "' .-r-tr..s''- k,,,` . . C.'''''}ik‘-'•,,,. . • • '.'' 7'''',.. .
' .. ',' .. 100,:....,IVO :
.0>rti)ai ihae„FtliiiikikiWqr,qglits'reserve.0...500ATiEl) A0ityg0 0 0,. IZED . .......4EDGt
,-. .wdontates'o'r iOrstere,d IIRclimarics of SolarEdge ipChndoglinc ilpIti S 4, en) ,1 tkon-eti Timm•'.4--,s•-1. r, ..-;., ,
- ,t trade mr.,6 Of i ell 145aective osvleGs:Dr,te:0120164002 st4 t,. 1.-SG C ...),s0 , ,,' ----Js
,
1 _.
N •
�
i
solar 1 ID ''
f) :- LU
tat i
NI
larEdge Power Optimizer 2 .
. .
Module Add-On For North America f---
-. _ P300 / P320 / P400 /, P4o5,.r__.__.�.�-__ ____w-_ _____v_.
i c
S
Lu
1
[1
1
i
1
J�7a,.�y
1143
:' 3g f"
�,_ -
4i
if, s
> 4a, _ /, A -4+.{; R 4L y.0- lid
i
3 '
.
�• -% as j f e f t
":
PV power optimization at the module-level
- Up to 25%more energy - - . -
m Superior efficiency(993%) •
, F Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading
1
Flexible system design for maximum space utilization - •
_
Fast installation with a single bolt _ - _ -
Next generation maintenance with module-level monitoring _ - yy�" _
Module-level voltage shutdown for installer and firefighter safety -
,,�. . - r_ --_--- - . _ ._
tlSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN--CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL ° -' www.solaredge.us
�a
solar - E 6 E SolarEdge Power Optimizer
Module Add-On for North America
__ _ - - __ P300 / P320 / P400 / P405
_ .____a P300 ._v_s_-- -�P320 -�_�- __—P400--,..s_-__s P405 -- -
(for 60-cell modules) (for high-power (for 72&96-cell (for thin film
60-cell modules) modules) modules)
INPUT
Rated Input DC Powerttl 300 I 320 400 405 W
Absolute Maximum Input Voltage 48 80 125 Vdc
(Voc at lowest temperature)
MPPT Operating Range 8-48 8-80 12.5-105 Vdc
Maximum Short Circuit Current(Ise) 10 11 10.1 Adc
Maximum DC Input Current 12.5 13.75 12.63 Adc
Maximum Efficiency 99.5 /o
Weighted Efficiency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) -
Maximum Output Current 15 Adc
Maximum Output Voltage 60 _ _ _ �____L 85 Vdc _
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power 1 Vdc
Optimizer ,
STANDARD COMPLIANCE
EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(class II safety),UL1741
RoHS Yes
•INSTALLATION'SPECIFICATIONS
Maximum Allowed System Voltage 1000 Vdc
Compatible inverters All SolarEdge Single Phase and Three Phase inverters
Dimensions(W x L x H) 128 x 152 x 27.5/ 128 x 152 x 35/ 128 x 152 x 48/
5 x 5.97 x 1.08 5 x 5.97 x 1.37 5x5.97x1.89 mm/in
Weight(including cables) 760/1.7 830/1.8 1064/2.3 gr/lb
Input Connector MC4 Compatible
Output Wire Type/Connector Double Insulated;MC4 Compatible
Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft
Operating Temperature Range -40-+85/-40-+185 'C/rF
Protection Rating IP68/NEMA6P
Relative Humidity 0-100 %
of Rated SIC power of the module,Module of up tots%power tolerance allowed.
PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
A SOLAREDGE INVERTERPI
Minimum String Length 8
10 18
(Power Optimizers)
Maximum String Length 25 25 50
(Power Optimizers)
Maximum Power per String 5250 6000 12750 W
Parallel Strings of Different Lengths Yes
or Orientations
rzl It is not allowed to ode P405 with P300/P400/P600/P700 In one string.
{
.`EAO1. a. 3' x
a4,. 4r 3, "
; It :-7....-
e.Sp,ird4e echgoo,s nG 11 ht.e e30110i1r 01i•Eb -oar • e.a 1511ZEo 4.1 111 GEIL ?> 4
Ip,f •r ttta'�det�le sro"registeredtrad.. ants:P-olatCtg tretootogt . I ears ema{tS 1potaned ejt>n'trt. 7,t- MOM
.,t ratlemancs-.t he respective-o`w Is 'Ite. 2 O. `1 r,,-bjec :c1�h. Jolt- • ' r e.
• . *
_--
Mono Multi Solutions
_________,•Nimma. -Al'
fOLUS+ . . • . .
. • lo 4 4.
iiiiDULE • 4 . . .
, — . • .
, .
. .. . .
• 4 .
, .
.. . i . . - • •
c .. .
[ ' 60 CELL
,,,,,.....
,. -mONOCRYSTALLINE MODULE
i
! ,270-295W
i -
i• •' ' POWER OUTPUT RANGE _,-
- t Maximize limited space with top-end efficiency
i- . 1 "4-44.4. ' • Up to 180 W/m2 power density
I .1' ...5-_, • Low thermal coefficients for greater energy production at high
, 1807 operating temperatures
• 0
AIVI1XiMUM EFFIC1EKY
fl
. - _-
i'cori-, Highly reliable due to stringent quality control
-w
1 , _ i • Over 30 in-house tests(UV,TC,HF,and many more)
i 7: 0 415-W
,_- , • In-house testing goes well beyond certification requirements
POSITIVE POWER TOLERANCE
_. • 100%EL double inspection
' •
,As a leading global manufacturer of' 7r- -„\ Certified to withstand challenging environmental
r• : ..F : neict gerierationnholovollattproducis.:' conditions
. „
we believe close cooperation with- t., • 2400 Pa wind lOad
:our partners is critical to success With ' . ,,,_, -
,,.;•••••.,„r , focal presence around the globe,Irina i• • 5400 Pa snow load
is able to provide exceptional service ' • 35 Min hail stones at 97 km,111
to each customer in each market and t,irt
upplenlent our Innovative. reliable, " •
products with the backing of Trine
as q strong, bankable partner. We . '• .
• -- - are committed to building strategic,
mutually her-let-Mid collaboration with
t installers,developers.distributors and
' other partners as the backbone of our
shared SUCCaSSin driving Smart Energy
Together. . s
. . •
'Irina Solar limIted Comprehensive products and system certificates
:, • : v.: - „. : .;•
wWw.binasolar,corn ,`:•,.1,` „ :V-:7'7 '' -
i •
-• - •
't. - -7.'". .:-. it' 1.-.1:-t -1. '.. ' •
• IEC 61215/IEC 61730/UL 1703/IEC 61701/tEC 62716
LINgAA FERFORMANCE WARRANTY . ISO 9001:Quality Management System
i Mi.Pro&d.Warranty..25 Year Unew P.m/WA tra otv • ISO UM:Environmental Management System
• 15014064:Greenhouse Gases Emissions Verification
i 1—11 ' 1,--44-,'.!4,-•.,,„,,,, - OHSAS i8001;Occupation Health and Safely Management System
T'''' ' - —- -•"" ;',,,,,„.
,p.,..,„ ..,„... .,••:,
bitateA cOUS kk ) (- ( • ' gilt: 1
I C,fr•ali'Vt24.e.1 ....."......A, , ;`,.....rs, M , ,
a Pi tYoLE
. :
,.....- _ .
—, -- -
• i IFsoia Irea r ,‘•,, , i 4.
. Smart EnergyTogether -. -.• • •i ,: •
r.,--g-'• 1Z-4,r::.- ,' —
ii.••• .A...........-.7 „..•:_:J.... . .-, A-._ ::"ii '. . ,
•
•
THE Ad MAX*
pLus. MODULE
PRODUCTS POWER RANGE ELECTRICAL DATA(STC)
.TSM-DDO5A,08(LI) •----275-295W Peak Power Watts-Pr44x(War • 270 275 280 285 290 295
A TSM=D005A.05(II) ' '270:290W Power Output Tolerance-P1wx(W) 0-4.5
Maximum Power VoltageVniP(V) 31.2 31.4 31,7 31.8 32.2 32.5
Maximum PowerCurrent-IMrr(A) 8.66 8.76 ' 8,84 8.97 9.01 9.08
. DIMENSIONS OF PV MODULE Open Circuit Voltage-Voc(V) 38.4 38.7 39.0 39.3 39.5 39.7
unit:mm/Inches Short Circuit Current-Ise(A) 9.18 9.26 9.35 9.45 9.50 9.55
ys 9TU37.o
--i Module Efficiency qm(%) 16.5 16,8 17.1 17.4 17.7 18.0
Junction Pell l_ STC:Irradiance 1000 W/m'.CellTemperature 25•C,Air Mass AMT.5,
a-A9=ts y Junction 'Test tolerance:33%.
.
Irul•� :Hole ,11
Ncrnspiala
II! $ ELECTRICAL DATA(NOCT)
1.1. Maximum Power-P.m(Wp) 201 205 209 212 216 220
5't AL '" c I
Maximum Power Voltage Vs,rr(V) 28.9 29.2 , 29.4 29.6 29.9 30.2
Maximum Power Current-hoer(A) 6.96 7.02 7.10 7.17 7.23 7.28
e•
Open Circuit Voltage-Voc(V) 35.7 1 36.0 i 36.3 • 36;6 36,7 36.9
34)43 Short Circuit Current-he(A) 7.41 7.48 7.55 7.63 7.67 7.71
Granting Holeg.
MOOT:Irradiance at 800 W/m',Ambient Temperature 20•C.Wind Speed 1 m/s,
I2-0ronn lisle
o MECHANICAL DATA
-
180R.1 Solar Cells Monocrystolline 156 x 156 mm(6 inches)
991/39.1
BackYww Cell Orientation 60 cells(6 x 10)
Module Dimensions 1650 x 992 x 35 mm(65.0 x 39.1 x 1,38 inches) .
SXcon Sedan! Weight 18.6 kg(41.0 lb)
11/0.43
tar'nato Glass 3.2 mm(0,13 inches),High Transmission.AR Coaled Tempered Glass
gi Backsheet White(DDO5A.08(11));Black(DDOSA.05(U))
Frame Black(DDO5A.08(II),DD05A.05(11))
Frans `
J-Box IP 67 or IP 68 rated sj
35/i.3e Cables Photovoltaic Technology Cable 4.0mm'(0.006 inches'),
A•A 1000 mm(39.4 Inches)
Connector MC4 Compatible or Amphenol H4/UTX
Fire Type Type 1 or Type 2
I-V CURVES OF PV MODULE(295W)
e '" TEMPERATURE RATINGS MAXIMUM RATINGS
c
I R.,sn Nominal Operating Cell 44°C(+2°C) Operational Temperature -40-+85°C
Temperature(NOCT) IOOOY DC(IEC)
e oaxr�' Maximum System Voltage
F 5 -•-•••- Temperature Coefficient of Pm4x -0.39%/°C 1000V DC(UL)
d . 0 Wq ____ Temperature Coefficient of Voc -0.29%/°C Max Series Fuse Rating 15A
' \ Temperature Coefficient of Ise 0.05%/°C
1 S+.
o I 10 15 20 25 70 30 40 44
vwo,re WARRANTY
. P-V CURVES OF PV MODULE(295W) 10 year Product Workmanship Warranty
25 year Linear Power Warranty
-_1t% (Please refer io product worronty for details) i
2w 111WANA11.1.1.
401r
PACKAGING CONFIGURATION
,m mrcare ii ! .i Modules per box:30 pieces • 1 z
290Wfm•0 ' . Modules per 40'container 840 pieces y'
e 5 ,C 15 ~23 25 30 S 4e 45
v.nwxa
!C-�• CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.
LEVarSdar fl 2016 Irina Solar limited.All rights reserved.Specifications included in this dolasheet are subject to change without notice.
Smart Energy Together •
, , , ,
ARC DIESIGN
409 N. MAINSTREET
ELMER, NJ 08318
(856) 712-2166 FAX: (850 358-1511
Date: July 3,2018
Re: Structural Roof Certification
Subj: Bishop Residence,823 State Route 149,Queensbury,NY 12804
We have provided a review of the roof construction of the above named property in regards to verifying
the capacity of the existing roof for installation of a new Solar Panel Array.
We have found the roof to be of wood frame construction bearing walls. Roof 1 is of 2x6 @ 16" o.c.
rafter framed roof with 2x4/1x8 @ 16"o.c. collar ties sheathed with lx plank decking and 3 layers of
asphalt shingle roofing. Roof 2 is of 2x4 @ 16"o.c. rafter framed roof sheathed with lx plank decking
and a single layer of composite shingle roofing.
The wood framed roof structure bears directly upon the framed exterior wall system. The existing
members as installed meet the required IRC-2015 design span ratings with sufficient capacity to carry
the 4#/sf additional load imposed by the proposed solar array per the details below.
Installation of solar rack systems shall be as follows:
Each panel row shall be supported upon 2 mounting rails. Rails shall be screw anchored
through roof and directly to rafters below.
Rail attachment points to rafters shall be staggered each row with exception to the first fastener
row from the gable end which is attached to two adjacent rafters.
A roofing compatible sealant or shingle flashing kit shall be utilized at each mtg.foot location.
Solar panel mounting systems installed parallel to the plane of a roof shall be no more than 12"
above the roof when measured perpendicular to the roof surface.
When installed per the above specifications the system shall meet the required 115 MPH wind load and
50 PSF ground snow load requirements.
Should you have any further question or comment please feel free to contact our office.
_._....j
Respectfully, _ ks,10V D ECM/ EL)
' Ili:),
\,co.` s: rA. 0444N
JUL 10 2018
ii
r � 7.
u .
6 i TOWN OF QUE1'NS uR
James A. Clancy eS)
BUILDING&CODES
Professional Engineer 'OA a842* 47
NY License#84288 41' PZS lat�l`�''
«,.,; Jul, 30. 201811 15AM.{ ,MDIA;, .,'�.�,,ya �1�;,:,,,;, „� ,� No. 4356 P. 4/6
.\'� 1T1� - r?�r- -t�'�i'.r-,_,r:C✓` �;✓..,,,,. •�> Rom%\'= 'C,:s;':y:Co5sx.T-Y1S�ya \_c\ -:, r .-:-r
z MIDDLE,T/ DEPARTMENT• 1�/`ti/+�.'l:J:iA �1 s,:/:;,,.\,_,:?. `.~'+.\���-k.?`-J J ri. s,2:mac:✓;�;asr
•
(tt,
INSPECTION AGENCY INC. \�>>
�� a that the electrical wiring to the electrical equipment listed below has been examined and is
\� beingapproved as
y, in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date Ill
i j noted below and is issued subject to the following conditions. Ill
Owner: ��jl
Wesley Bishop Date: 07/24 2018 el g
�;� Occupant: •
Solar PV System Location. 0C�'•j 823 Route 149 -�� OccupancySingie Family Dwg, Queensbury, Warren Co. NY ��
q�) r:
Applicant: —1
` •
l . Apex Solar Power _ y-
' Stree _ "..`; �c>a
64 Main t ;,, w' _
J _ /
(y;• Queensbury NY 12804.,'.r = =_ ti. - -- Qi
i a) L I Sad
s Joseph A_Molmes •.....•• ••..• • • ,. �
�,
ktp
•
•
(j No. - :1457781040551=L _ •. ....... t>> -
i`'y Equipment: ; - - - - - - _.:_ •
'. ... ..
f{
,)30-Solar Modules; 1 -7600 Watt Inv rter,•2' AC-Discanne'ts; 1 -tine-Side Tap ---,�•' . - <•<�
6 .\ , •
tip
,r
? (6)
�_: •
fir.j
p; This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void, This certificate applies only to the use,occupancy and .4.4
•4,1 above end the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or Ownership (P)1
(4 inspection. No warranty is expressed or Implied as to the mechanical safety,effl- of the property indicated above,this certificate shall be immediately nun and void, eh)
r:c ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above condlbons,
\• be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon ►elnspection by Middle Department ( �
system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle (�=��
(�h) ed to,the Introduction of additional electrical equipment andfor the replacement of Department Inspection Agency.Inc.to initiate the inspection and revalidation ((j�
'As, any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. ;•
\<' `rr-: i .\t;\A;\i; i45�y;r�Cr�':'r:�' % 'r iR;i;�":;iio :1.,j�'-f 7;:r �i.%�i cU 7%`\.•i.�•�S:-��•�/'1:1.r\. \..��r. .�.�.•--v�v:�� 1 ^-7,\•N;.:f-�l ,
.4,4 r tr=1!:�l,:�J:`✓-✓ ,1:vh"r,tf':.%:✓:..�'•n�'`e}t:k-t,x� cV%�=1�!�'S,r�:J4�v/`t%:�: `A..x,..9 i/"=:�\` ,,� �`•J•�tU��r rR c�-yr��•l�4 `.,,f..''a.,,,,,,jam
•
JQill ' Q —4 2-OvES
5 E C E 11 1\17\-1 1-7--1--' [nl
• la AUG 01 2018 •
TOWN OF OiUEENSBUry'
•
BLIP DiN1. st CODES,.