Loading...
RC-0404-2018TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0404-2018 Date Issued: Wednesday, February 20, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-0404-2018 Tax Map Number: Location: Owner: 301.5-1-3.2 757 WEST MOUNTAIN RD Scott Rowland, Jodi Rowland Scott RowlandApplicant: This structure may be occupied as a: Single Family Dwelling w/wood stove 2160 s.f. New att. Garage 595 s.f. Cross. Ref. SUB 6-2018 approved 2-lot subd.; Z-AV-27-2018 Approved for 2nd garage (existing), min. road frontage and lot width 5/16/2018 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement TOWN OF QUEENSBURY ,, 11 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 ",w -, - - . Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0404-2018 Tax Map No: 301.5-1-3 Permission is hereby granted to: Scott Rowland For property located at: 757 W Mountain RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Scott Rowland - Single Family-New $125,000.00 Owner Address: 68 Wisconsin AVE Total Value $125,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Scott Rowland 68 Wisconsin AVE Queensbury,NY 12804 Plans&Specifications Single Family Dwelling w/wood stove 2160 s.f. New att.Garage 595 s.f. Cross.Ref. SUB 6-2018 approved 2-lot subd.; Z-AV-27-2018 Approved for 2nd garage(existing),min.road frontage and lot width 5/16/2018 $ 1,656.50 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday,July 13,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Que sbury F d,y 14 ,2018 i SIGNED BY: f- \. for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only �.a ' MPermit#: Q-C-C404- Zt)tO t t PRINCIPLE STRUCTURE, MOM' Permit Fee:$ 801Q. z) - APPLICATION ` *Rec. Fee:$ &DO 742 Bay Road,Queensbury, NV V804 P: 518-761-8256 www .queen.,bury net • Invoice ix:: CO59 T%J- :. Project Location: �J No: r Tax ICI::p #: 0'1. Gam— / 3� Subdivision Name: OaJ/4- 6Y - /OH TOWN SD.RESOLU T!ON 86-2013:$850 recreation fee for new dwelling units: single family, duplexes/two-family, multiplefamily, apartments,condominiums, townhouses,and/or manufactured & modular homes, but not mobile homes. This is in addition to the permit fee(s). CONTACT INFO RMA T ION: • Applicant: Name(s): 6 de-4 - c) i1'1 1 Mailing Address, C/S/Z; Cn 3 GO is 00,,-)S Cell Ph.: ( 516 ) t3,-- I 0 Land Line: ( ) Email: e Primary Owner(s)A Name(s): (1, J Doi -il'YlvJ inn Mailing Address, C/S/Z: Cell Ph.; ^( ) Land Line: _( ) _ Email: El Wi n • Contractor(a)o JUN 2 6 201$ Name(.): �► )vvv • h Mailing Address, C/S/Z: TO\NN OF Q.UEENSl t1RY Cell Ph.: _( ) Land Line: ( ) Email: • Arrchitect(a)/Sn eer( Name(s): Mailing Address, C/S/Z: Cell Ph.: _( ) Land Line: _( ) Email: Contact Person for Building & Code Compliance: c_otk- Qeml\t tr,ra Cell Ph.: ( ) Land Line: ( ) Email: • Te.A n..:u:....4.!'e.rle,Cn£rerr,nr,+ Drinriniea Ctrurtnrn Dnviend March 11112 V PROJEGI_NFORM TION; TYPE: Commercial Dic � siderzi:il WORK CLASS: i)( Single-Family T a-Family Multi-Family(#of •_-Townhouse Bugines Office Retail • Hotel/Motel industrial/'Warehouse earage(#ofcare ) Other(describe T_ } ERA ELM MUARE fQOTT.Cfo yiikkgmyARE FOOTAGE: 1ST floor: arc, 0 1ST floor: 5s1 P"d floor: 2"d floor: PI floor: Total square feet: Basement(habitable space): Total square feet: ADDITIONAL PROJECT INFOV ATION: 1. Estimated Cost of Construc ion: $ Jc S; Do 0 2. Proposed use of the build' gig: t c 1 A.-0A+ 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): Gas Oil Propa Solar Other: _ (Fireplaces need a separat- Fuel Burning Appliances&Chimney Application, one per appliance) 5. Are there any structures n•t shown on the plot plan? YES .6 Explain: 6. Are there any easements o the property? YES 44 7. SITE INFORMATION: a. What is the dimensions .r acreage of e parcel? .2 ?jto .C. b. Is this a corner lot? YES NO c. Will the grade be chang_d as.a rest t • _he construction? YES 010 d. What is the water sourc-? nUBL PRIVATE WELL e. Is the parcel on SEWER .r a PRIVATE SEPTIC system? SL Tear!ILaiWino 2.revin Cnb.ww.......a _ _ _ - .__ wip D LifillAti N • • acknowledge that no construction pror to issuance'uf a and work will he completed with in a 12 month period. • 2. If the. Work is not completed by the iyeer e4iration date the permit may be renewed, subject to fees and department approval. • • 3. I certify that the application, plans and supporting. materials are a t rue and compWte statement and/or description of the work proposed, that ail work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with 1=1 zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I understand that 1)We are required to provide an as-built survey by a licensed land surveyor of a II newly constructed facilities prior to issuance of a certificate of occupancy. • have read and agree to the above: PRINT NAME:. 6. _ SIGNATURE: DATE: T2V- • • • • • • .t ;.��• Office Use Only r � i* ii,,,, tm ,,,3,'� : FUEL BURNING APPLIANCE Permit : 1 -E. b ,,y�16 tip; � r' '�z.; _ _ �; ;�' :: CHIMNEY APPLICATION Permit Fee:$ 'x ?i ii invoice:.: ;,,car Queeosbo , ! i t - - _ - 74•2 Bay Road, Queensbury, N 19804 P: 518-761-8256 Www:queenshurv:net Project Location: tti1e..,c4-d1%,m , i a Tax Map ID: Room of Install: Ltv1 a--- Planned Install Date: "ONE APPLICATION PEA.APPLIANCE" . • Applicant: Name(s): SGA4\-- PIda Mailing Address, C/S/Z: (o ) ,s 0',)'S)lti mil- , Cell Ph.: _,_,( 7Q' ) t9 - 3cf.I 0 Land Line: ( ) Email: • Primary Ownei'(s): Name(s): �� Mailing Address, C/S/Z: Cell Ph.: _( ) Land Line; _( ) Email: , • Installer/Builder, Name(s): -- __ Mailing Address, C/S/Z: Cell Ph.: _( ) Land Line; _( ) Email: Contact Person for Building & Code Compliance: Cell Ph.: _( ) Land Line: _( ) Email: Town of Queensbury Building&Code Enforcement de FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: • Stove Fireplace Insert Fireplace Fuel Fired Equipment(Garage Only,13"clearance per IMe304.3) /; Fireplace, factorybuilr* Manufacturer's Name: — -- — Madel - — — SOURCE OF HEAT: W00 : Coal Pellet Gas CHIMNEY INFORMATION: _Masonry; block brick stone Flue: tie el° _ size'in inches Material*: double-wall _ triple-,wa II_insulated (*Manufacturer's m _ - Model#: ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection,prior to installation and a final inspection,after installation. 2 Manufacturer's installation manual must be available at the time of inspection. 3 Masonry fireplaces & chimneys require plans to be submitted. 4 Twenty-four (24) hour notification is required for hspections. Declaration:Construction/installation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements.The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part ofthese requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: — SIGNATURE : /+ 4, j V DATE_ Fuel Burning Appliance&Chimney Application V ' EPT-IC DISPOSAL PERMIT APPUCATI O Office a nI 7412 Bay Road,Queensbury,NY 12804 P:518-761-8256 >: >;;... . Pert h- •• -Ozi'o ' 53 I4S...,.. .� . Tax Map ID*: Permit Fee:$ •irivoi( .)t: h roject Location: Septic Variance? Yc; N o Primary Owner(s) Mailing Address Phone& Email s-Installer/Builder Mailing Address m_ s Phone & Email — engineer _ — Mailing Address �.�_ -- _ --..._._...._Phone& Email • Contact Person for Building&Code Phcomae: RESIDENCE NFORMATION: Year Built #of bedrooms X gallons per bedroom = totaidaily flow Garbage Grinder Yes 4 1980 or older Installed? {circle one) 1981-19991 • Spa or Hot Tub Yes 41250 • Installed? {circle one) a92-orresent PARCEL INFORMATION: Topography lat�2ol Steep Slope %Slope Soil Nature Sand Loam Clay _Other Groundwater At what depth? Bedrock/Imperviousmaterial At what depth? Domestic Water Supply [ Municipal _Well{if well,wate r supply from any septic system absorption is ft.) Percolation Test Rate; per minute per inch{test to be completed by licensed engneer/archtect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size I J -p gallons{min.size 1000 ga llons,add 250 ga lions for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length ' s-z ft.;EachTrench ft' Seepage Pit with#3 stone !How many: , Size: Alternative System Bed or other type: HoldingTank System iTotal required capacity?. -tank size ;# of tanks NOTES:1.Alarm system&associated electrica!work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file-no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and all requirements oftheTown of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: DATE: SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Reui act FahrLLry 7n17 Town of Queensbury Thomas R.Van Ness Highway C4epartment Highway Superintendent 742 Bay Road,Queensbury, NY 12804 Home:518-745-0929 Phone: 518-761-8211 Fax:518-745-4.4-66 David Duel! Deputy Highway superintendent Home: 518-745-0938 DRIVEWAY PERMIT Date: Applicant Name: C� l°9 \tem,d. Telephone No,: � - 3`7 I 0 Address to be Inspected: �<-Qe)— +- -Return Address; Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location, The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary approval NEED ( ) Slight Swale . ( ) Deep Swale ( ) Level with the road O Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15„ ( ) 18„ ( ) 24" ( )36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R.Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent Town of Queensbury Building&Code Enforcement Principal Structure Application Revised February 2017 INSPECTION WORKSHEET (FMWOOD-000902-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0404-2018 Case Module:Permit Inspection Date:Mon Feb 11, 2019 Inspection Status:Passed Inspector:Mike Palmer Inspection Type:Wood Burning Fireplace/Stove Job Address:Parcel Number:757 West Mountain RD Queensbury, NY 12804 301.5-1-3 Contact Type Company Name Name Primary Owner Rowland, Scott Primary Owner Rowland, Jodi Granted Permission Rowland, Scott Applicant Rowland, Scott Contractor Rowland, Scott Checklist Item Passed Comments Fire Marshal Notes YES Security Fireplace Model Altima Floor Protection YES Clearances to Combustibles (all sides)YES Safety Strip Installation (fireplaces only)YES Firestop(s) - Vertical Chase YES Chimney Clearances to Combustibles YES Chimney Termination YES Feb 11, 2019 Page (1) INSPECTION WORKSHEET (FMWOOD-000902-2019) Checklist Item Passed Comments Combustion Air YES Hearth Extension YES Mantel-height above fp opening YES Fireplace Doors Screen (required)YES Carbon Monoxide Detection YES Feb 11, 2019 Page (2) Scott Palmer, Mike (Inspector) f Town of Queensbury -Building and Codes -Fire Marshal 742 Bay Road -(518) 761-8256 Building (518)761-8206 Fire Marshal Case Number: RC-0404-2018 Case Module: Permit Inspection Date: Mon Feb 11, 2019 Inspection Status: Passed Inspector: Mike Palmer Inspection Type: Wood Burning Fireplace/Stove Job Address: 757 West Mountain RD Parcel Number: 301.5-1-3 Queensbury, NY 12804 Contact Type Company Name Name Primary Owner Rowland, Scott Primary Owner Rowland, Jodi Granted Permission Rowland, Scott Applicant Rowland, Scott Contractor Rowland, Scott Checklist Item Passed Comments Fire Marshal Notes YES Security Fireplace Model Altima Floor Protection YES Clearances to Combustibles (all sides) YES Safety Strip Installation (fireplaces only) YES Firestop(s) -Vertical Chase YES Chimney Clearances to Combustibles YES Chimney Termination YES Feb 11,2019 ___ Page(1) Checklist Item Passed Comments Combustion Air YES Hearth Extension YES Mantel-height above fp opening YES Fireplace Doors Screen (required) YES Carbon Monoxide Detection YES Scott Palmer, Mike(Inspector) Feb 11,2019 Page(2) s : t -°► REScheck Software Version 4.6.4 V ' Compliance Certificate DECEUVE0 Project ill JUN 2 6 2018 Energy Code: 2015 IECC Location: Glens Falls, New York TOWN OF QUEENSBURY Construction Type: Single-family BUILDING&CODES Project Type: - New Construction - "'-`"" Conditioned Floor Area: 2,160 ft2 Glazing Area _ 11% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: WEST KOAJNTAIN RD QUEENSBUY, NY 12804 / Compliance:Passes using UA trade-off Compliance: 2.0%Better Than Code Maximum UA: 300 Your UA: 294 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter • Ceiling 1: Raised or Energy Truss 2,160 49.0 0.0 0.020 43 Wall 1:Wood Frame, 16"o.c. 1,800 21.0 0.0 0.057 86 • Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 165 0.290 48 Door 1: Glass .. 40 0.290 12 Door 2: Solid - 33 0.280 9 Door 3: Solid 20 0.170 3 Door 4: Solid 40 0.280 11 Basement Wall 1: Solid Concrete or Masonry 1,600 0.0 13.0 0.051 82 Wall height: 8.0' Depth below grade: 7.0' - Insulation depth: 8.0' ��o' NE14-�� . -- " .;�.. �� Compliance Statemen It ,p oin I_Idil g ' sign described here is consistent with the building plans, specifications, and other calculations submitt with tf permit a ply tion!The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4 4-agt<to co ,no 'with i'e ar�datory requiremen listed in th7 / / L eck InspChecklist. r V'r .Z. I O, --ay/� Name-Title -\ ".::�' ' :�j t );. Si e Dat co' R�1 4 2. ,. C01 - ':::'301.5-1-3.2 RC-0404-2018 Rowland, Scott &Jodi Project Title: 757 W. Mountain Road Report date: 05/09/18 Data filename: Untitled.rck 1 SFD w/wood stove 2160 s.f., Gar. 595 s.f. Page 1 of 9 1r REScheck Software Version 4.6.4 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.1D 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate '❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, ;Construction drawings and ;❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 ;energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable :09 Systems serving multiple i❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, ;Heating and cooling equipment is Heating: E Heating: ❑Complies 403.7 sized per ACCA Manual S based f Btu/hr ; Btu/hr ❑Does Not [PR212 :on loads calculated per ACCA Cooling: Cooling: iii :Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 2 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &I2eeq.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- ❑Does Not ;table for values. 4,10 insulation is used,verification E❑Not Observable may need to occur during ; "Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 'Conditioned basement wall ❑Complies [FO5]1 'insulation installed per !❑Does Not =,manufacturer's instructions. ;❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft :❑Complies :See the Envelope Assemblies [FO6]1 insulation depth of burial or °❑Does Not ;table for values. J 'distance from top of wall. g❑Not Observable : ❑Not Applicable 303.2.1 `A protective covering is installed ❑Complies [FO11]2 ,to protect exposed exterior ;❑Does Not ;insulation and extends a Observable i ;minimum of 6 in.below grade. ❑Not Applicable 403.9 ;Snow-and ice-melting system ❑Complies [FO12]2 'controls installed. i❑Does Not ONot Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 3 of 9 Section Plans Verified Field Verified # Framing I Rough-In Inspection Value Value Complies? Comments/Assumptions &Req.ID r 402.1.1, Door U-factor. U- U- ❑Complies ;See the Envelope Assemblies 402.3.4 ❑Does Not °table for values. [FRl]1 i ;❑Not Observable ; ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies ;See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 r p i 303.1.3 `U-factors of fenestration products ❑Complies [FR4]1 tare determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable itaken from the default table. ❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier :❑Complies [FR23]1 installed per manufacturer's ODoes Not instructions. ❑Not Observable j❑Not Applicable 402.4.3 ;Fenestration that is not site built ;❑Complies [FR20]1 is listed and labeled as meeting `❑Does Not AAMA/WDMA/CSA 101/1S.2/A440 ;or has infiltration rates per NFRC ❑Not Observable ;400 that do not exceed code ❑Not Applicable limits. 402.4.5 :IC-rated recessed lighting fixtures'. ❑Complies [FR16]2 sealed at housing/interior finish !❑Does Not and labeled to indicate- 2.0 cfm ; ;leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ' ;❑Complies [FR12]1 insulated >= R-8 where duct is ' ;ODoes Not >=3 inches in diameter and >= R-6 where<3 inches.Supply and; ❑Not Observable return ducts in other portions of i ❑Not Applicable the building insulated >= R-6 for diameter>=3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 'Building cavities are not used as ❑Complies [FR15]3 ,ducts or plenums. :❑Does Not ❑Not Observable ❑Not Applicable 403.4 ;HVAC piping conveying fluids R- ' R- i0Complies [FR17]2 above 105°F or chilled fluids -❑Does Not 'below 55°F are insulated to>_R- ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ; ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ;❑Complies [FR18]2 `>_R-3. ❑Does Not ❑Not Observable [-_]Not Applicable 403.E Automatic or gravity dampers are; ❑Complies [FR19]2 'installed on all outdoor air i❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 4 of 9 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 5 of 9 ' f Section insulation Inspection Plansienfie FieldVerified Complies? Comments/Assumptions &lt'eq.ID tVue 303.1 ;All installed insulation is labeled ; ❑Complies [IN13]2 I or the installed R-values InDoes Not provided, ❑Not Observable ❑Not Applicable 402.1.1, ,Wall insulation R-value.If this is a R- R- ;❑Complies See the Envelope Assemblies 402.2.5, I mass wall with at least 112 of the Wood ;❑ Wood IODoes Not table for values. 402.2,6 wall insulation on the wall I❑ Mass I D Mass .❑Not Observable [IN3]1 exterior,the exterior insulation ;requirement applies(FR10). _❑ Steel ❑ Steel ❑Not Applicable 303.2 ;Wall insulation is installed per '❑Complies [IN4]l manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 6 of 9 Section # Final Inspection Provisions Plans alaef°ed Field Verified Complies? Comments/Assumptions &Itegib '" 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.E ;❑ Steel ❑ Steel QNot Observable [FIl]1 - ?❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 :Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 ;Vented attics with air permeable ; ;❑Complies [FI2212 'insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ElComplies [FI3]1 ;insulation _?.R-value of the ;❑Does Not :adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 :Blower door test @ 50 Pa. <=5 i ACH 50= ACH 50 = :❑Complies [FI17]1 :ach in Climate Zones 1-2, and ElDoes Not • <=3 ach in Climate Zones 3-8. aQNot Observable E ❑Not Applicable 403.2.3 iDuct tightness test result of<=4 cfm/100 cfm/100 '❑Complies [FI4]1 ;cfm/100 ft2 across the system or ft2 ft2 ❑Does Not P<=3 cfm/100 ft2 without air :handler @ 25 Pa.For rough-in ❑Not Observable :tests,verification may need to ❑Not Applicable occur during Framing inspection. 9 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 :❑Does Not :either: Rough-in test:Total ;leakage measured with a ❑Not Observable ;pressure differential of 0.1 inch ❑Not Applicable !w.g. across the system including y the manufacturer's air handler r enclosure if installed at time of `test. Postconstruction test:Total leakage measured with a a • pressure differential of 0.1 inch w.g. across the entire system `including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of 10Does Not design air flow. ;QNot Observable ❑Not Applicable 403.1.1 'Programmable thermostats ❑Complies [F19]2 ;installed for control of primary ❑Does Not iheating and cooling systems and :initially set by manufacturer to ❑Not Observable :code specifications. ?❑Not Applicable 403.1.2 Heat pump thermostat installed i❑Complies [Fi10]2 on heat pumps. ❑Does Not QNot Observable ❑Not Applicable 403.5.1 ;Circulating service hot water '❑Complies [F1ll]2 systems have automatic or :❑Does Not accessible manual controls. QNot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck • Page 7 of 9 r + f Section # Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions & Fleob Value Value 403.6.1 ;All mechanical ventilation system '❑Complies [FI25]2 fans not part of tested and listed ❑Does Not 'HVAC equipment meet efficacy and air flow limits. ❑Not Observable ; ;❑Not Applicable 403.2 'Hot water boilers supplying heat ElComplies a [F126]2 'through one-or two-pipe heating ❑Does Not :systems have outdoor setback ❑Not Observable control to lower boiler water temperature based on outdoor ,DNot Applicable temperature. 403.5.1.1 Heated water circulation systems ; :]Complies [F128]2 have a circulation pump.The i0Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply: :pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal ;for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and a no demand for hot water exists. 403.5.1.2 Electric heat trace systems :❑Complies s [FI29]2 :comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the;adjust Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [FI30]2 have recirculation pumps that ODoes Not ;pump water from a heated water ,supply pipe back to the heated ❑Not Observable 'water source through a cold ;❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 'Drain water heat recovery units DComplies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water , 'heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FIEF fixtures or 75%of permanent ;❑Does Not fixtures have high efficacy lamps. ?Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ilDComplies [FI2373 :no continuous pilot light. ❑Does Not '%' ;❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 8 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &F{eq.JD 401.3 ;Compliance certificate posted. ;QComplies iF1732 ; Does Not QNot Observable QNot Applicable 303.3 ,Manufacturer manuals for QComplies [F118]3 i mechanical and water heating QDoes Not systems have been provided. QNot Observable QNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 05/09/18 Data filename: Untitled.rck Page 9 of 9 C.I 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 13.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.29 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments L `�1 Manual S Compliance Report Job: ROWLAND Date: Jun 11,2018 Entire House By: SCOTT ROWLAND Plan: ROWLAND WEST MOUNTAIN RD,QUEENSBURY,NY 12804 Project Information For: SCOTT ROWLAND WEST MOUNTAIN RD, QUEENSBURY, NY 12804 • Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 26664 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 7092 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 33756 Btuh Indoor RH: 50% Estimated airflow: 1154 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: CZFO3614C+FC48C3XNI Actual airflow: 1147 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 114794 Btuh Entering coil DB: 65.1°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X100C16MP11 Actual airflow: 1147 cfm Output capacity: 95000 Btuh 83% of load Temp. rise: 50 °F 301.5-1-3.2 RC-0404-2018 Rowland, Scott&Jodi 757 W. Mountain Road 5ECEEWEO SFD w/wood stove 2160 s.f., Gar. 595 s.f. �11 JUN 2 6 2018 • Meets are all requirements of ACCA Manual S. TOWN OF QUEENSBURY BUILDING&CODES 2018-Jun-11 10:55:10 wrightsoft° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...tt.langeworthy\Documents\York\SCOTT ROWLAND.rup Cale=MJ7 Front Door faces: N Residential Plans Examiner Review Form Form ACCk��� RPER 1 . for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 AtCandtcnig CoreachrsofAmeria QUEENSBURY NY . Header Information Contractor: REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes 0 No Ei Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No Building plan#: ROWLAND Manual D Friction Rate Worksheet: Yes 0 No Duct distribution sketch: Yes 0 No (] Home address(Street or Lot#,Block,Subdivision): WEST MOUNTAIN RD, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 114794 Btuh Number of bedrooms: 3 Conditioned floor area: 6440 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib @50% RH Eave overhang depth: 0 ft Sensible heat gain: 29627 Btuh Internal shade: none Blinds,drapes,etc. Eave Latent heat gain: 7880 Btuh Depth window Total heat gain: 37507 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Equipment type: Split AC Heating cfm: 1147 Furnace,Heaf pump,Boiler,etc. Air Conditioner,Heat pump,etc. Cooling cfm: 1147 Model: York Model: York Static pressure: 0 in H2O TM9X100C16MP11 CZFO3614C+FC48C3XN1 Fan's rated extemal static pressure for design airflow Heating output capacity:. 95900 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at wmter design ou door conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) , Design airflow: 1147 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP+(TELx 10 ) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality orAuthority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist * wrightsar Right-Suite®Universal 2017 17.0.16 RSU25116 Project Summary Job: ROWLAND Date: Jun 11,2018 s - * Entire House By: SCOTT ROWLAND Plan: ROWLAND WEST MOUNTAIN RD,QUEENSBURY,NY 12804 Pro'ect Information For: SCOTT ROWLAND WEST MOUNTAIN RD, QUEENSBURY, NY 12804 Notes: Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr./lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 107992 Btuh Structure 25421 Btuh Ducts 6802 Btuh Ducts 1243 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 114794 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 23998 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 7092 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2 6440 6440 Equipment latent load 7092 Btuh Volume(ft3) 57960 57960 Air changes/hour 0.70 0.40 Equipment total load 31089 Btuh Equiv.AVF (cfm) 676 386 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade AFFINITY Model TM9X100C16MP11 • Cond CZFO3614C AHRI ref 2008692 Coil FC48C3XN1 AHRI ref 5646624 Efficiency 95.5 AFUE Efficiency 12.3 EER, 14 SEER Heating input 100000 Btuh Sensible cooling 24080 Btuh Heating output 95000 Btuh Latent cooling 10320 Btuh Temperature rise 75 °F Total cooling 34400 Btuh Actual air flow 1147 cfm Actual air flow 1147 cfm Air flow factor 0.010 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2018-Jun-11 10:55:10 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...tt.langeworthy\Documents\York\SCOTT ROWLAND.rup Cale=MJ7 Front Door faces: N Right-J®Worksheet Job: ROWLAND 9 - T Entire House Date: Jun 11,2018 SCOTT ROWLAND Plan: ROWLAND WEST MOUNTAIN RD,QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Entire House Room1 Room2 Room3 2 Length of exposed wall 599.9 ft 200.0 ft 200.0 ft 31.0 ft 3 Room dimensions 1.0 x 2160 ft 1.0 x 2160 ft 18.0 x 13.0 ft 4 Ceilings Condit.Option 9.0 ft d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 5400 **** **** 1800 **** **** 1800 **** **** 279 **** **** Exposed b 0 0 Him **** **** I I I I I I **** **** I I I I I I **** **** I I I I I I **** **** walls and c 0 0 'mu **** **** Him **** **** IIIIII **** **** III **** **** partitions d 0 0 IIIIII **** **** 111111 **** **** IIIIII **** **** IIIIII **** **** • e 0 0 IIIIli **** **** IIIIII **** **** IIIIII **** **** Mill **** **** f 0 0 II" **** **** IIIIII **** **** IIIIII **** **** IIIIII **** **** 6 Windows and a 3A0 39.7 ** 230 9125 **** 20 793 **** 0 0 **** 30 1190 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** . 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 75 **** 1425 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 110 **** 7480 20 **** 1360 0 **** 0 30 **** 2040 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 45 **** 1530 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 126 4173 788 0 0 0 0 0 0 42 1391 263 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 5044 27238 5145 1780 9612 1816 1800 9720 1836 207 1118 211 exposed b 0 0 nnn 0 0 IIIIII 0 0 Inns 0 0 111111 0 0 walls and c 0 0 null 0 0 ' IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 partitions d 0 0 winwin0 0 111111 0 0 111111 0 0 IIIIII 0 0 e 0 0 will 0 0 111111 0 0 111111 0 0 IIIIII 0 0 f 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII . 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 4280 10169 4802 0 0 0 2160 5132 2424 234 556 263 b 0 0 min 0 0 111111 0 0 111111 0 0 IIIIII 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 IIIIII d 0 0 will 0 0 111111 0 0 1111110 0 0 0 111111 0 0 e 0 0 null 0 0 III!! 0 0 IIIIII 0 0 111111 0 0 f 0 0 null 0 0 Innl 0 0 IIIIII 0 0 111111 0 0 11 Floors a 1910 1.7 0 2160 3732 0 2160 3732 0 0 0 0 0 0 0 (Note:room b 0 0 111111 0 0 win 0 0 111111 0 0 111111 0 0 perimeter c 0 0 null 0 0 111111 is displ. d 0 0 null 0 0 win0 0 111111 0 0 111111 0 0 0 0 nnn 0 0 111111 0 0 for slab e 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 floors) f 0 0 IIIIII 1111110 0 0 0 111111 0 0 111111 0 0 12 Infiltration a 150 11.9 356 53555 4250 20 3009 239 0 0 0 72 10831 860 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8,.+11+12 **** 107992 **** **** 17147 **** **** 14852 **** **** 15086 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 6802 **** 6% 1080 **** 6% 935 **** 6% 950 **** 15 Total loss=13+14 **** 114794 **** **** 18227 **** **** 15788 **** **** 16037 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. © 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 25421 **** **** 3414 **** **** 4260 **** **** 3636 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 1243 5% **** 167 5% **** 208 5% **** 178 19 Total RSH gain=(17+18)*PLF 1.00 **** 26664 1.00 **** 3581 1.00 **** 4468 1.00 **** 3814 20 Air required(cfm) 1147 1147 182 154 158 192 160 164 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. -rid- wrightsoft- Right-Suite®Universal 2017 17.0.16 RSU25116 2018-Jun-11 10:55:10 Page 1 /CCk ...tt.langeworthy\Documents\York\SCOTT ROWLAND.rup Calc=MJ7 Front Door faces: N • Right-J®Worksheet Job: ROWLAND Y F Entire House Date: Jun 11,2018 SCOTT ROWLAND Plan: ROWLAND WEST MOUNTAIN RD,QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room4 Room5 Room6 Room7 2 Length of exposed wall 12.0 ft 47.0 ft 26.0 ft 8.0 ft 3 Room dimensions 12.0 x 23.0 ft 1.0 x 729.0 ft 13.0 x 13.0 ft 8.0 x 8.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 108 **** **** 423 **** **** 234 **** **** 72 **** **** Exposed b 0 0 !urn **** **** II III I **** **** 1 I I I I I **** **** I I I I I I **** **** walls and c 0 0 111111 **** **** Him **** **** IIIIII **** **** 1IIIII **** **** partitions d 0 0 111111 **** **** Illlit **** **** IIIIII **** **** I II111 **** **** e 0 0 !urn **** **** IIIII1 **** **** win **** **** Illlll **** **** f 0 0 IIIIII **** **** II" **** **** Hull **** **** Illlll **** **** 6 Windows and a 3A0 39.7 ** 30 1190 *`** 45 1785 **** 30 1190 **** 10 397 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 `*** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 *** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 30 **** 570 30 **** 570 15 **** 285 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 15 **** 1020 10 **** 680 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 15 **** 510 0 **** 0 0 **** 0 Holz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 63 2087 394 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 78 421 80 315 1701 321 204 1102 208 62 335 63 exposed b 0 0 Innl 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 Hull0 0 null partitions d 0 0 111111 0 0 lulu0 0 111111 0 0 111111 0 0 0 0 111111 0 0 IIIIII 0 0 e 0 0 111111 0 0 IIIIII 0 0 111111 0 0 111111 f 0 0 nnn 0 0 111111 0 0 1111110 0 0 0 IIIIII 0 0 10 Ceilings a 16G0 2.4 1.1 276 656 310 729 1732 818 169 402 190 64 152 72 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 • d 0 0 111111 0 0 111111 0 0 IIIIII 0 0 0 0 IIIIII 0 0 e 0 0 Illlll 0 0 Illlll 0 0 nnn 0 0 nnn f 0 0 IIIn! 0 0 In ln0 0 0 0 nnn 0 0 Inns 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 0 0 will 0 0 ruin 0 0 111111 0 0 111111 0 0 perimeter c 0 0 HIMHIM0 0 111111 is displ. d 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 Hui! 0 0 111111 0 0 111111 0 0 0 0 IIIIII 0 0 IIIIII 0 0 Illlll 0 0 floors) f 0 0 IIIIII 0 0 IIIIn 0 0 null 0 0 IIIIII 0 0 12 Infiltration a 150 11.9 30 4513 358 108 16247 1289 30 4513 358 10 1504 119 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 6780 **** **** 23552 **** **** 7206 **** **** 2388 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 427 **** 6% 1483 **** 6% 454 **** 6% 150 **** 15 Total loss=13+14 **** 7207 **** **** 25035 **** **** 7660 **** **** 2538 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 1317 **** **** 3903 **** **** 2061 **** **** 934 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 . Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 64 5% **** 191 5% **** 101 5% **** 46 19 Total RSH gain=(17+18)*PLF 1.00 **** 1382 1.00 **** 4094 1.00 **** 2162 1.00 **** 980 20 Air required(cfm) 72 59 250 176 77 93 25 42 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. .� wrightsOft® 2018-Jun-11 10:55:10 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ACC ...tt.langeworthy\Documents\York\SCOTT ROWLAND.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: ROWLAND Entire House Date: Jun 11,2018 r _ f SCOTT ROWLAND Plan: ROWLAND WEST MOUNTAIN RD,QUEENSBURY,NY 12804 . MANUAL J:7th Ed. 1 Name of room Room8 Room9 Room10 Room11 2 Length of exposed wall 28.0 ft 7.0 ft 0 ft 0 ft 3 Room dimensions 13.0 x 15.0 ft 7.0 x 4.0 ft 3.0 x 11.0 ft 4.0 x 11.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 252 **** **** 63 **** **** 0 **** **** 0 **** **** Exposed b 0 0 mill **** **** IIIIII **** **** IIIIII **** **** IIIIII **** **** walls and c 0 0 1111II **** **** In11I **** **** IIIIII **** **** 111111 * **** partitions d 0 0 null **** **** Illlll **** **** will **** **** 111111 **** **** e 0 0 II1111 **** **** III III **** IIIIII IIIIII **** f 0 0 IIIIII **** **** IIIIII **** **** IIIIII **** **** II!II I **** **** 6 Windows and a 3A0 39.7 ** 45 1785 **** 0 0 **** 0 0 **** 0 0 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 ** 0 0 0 0 e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 15 ** 1020 0 * 0 0 **** 0 0 * 0 SE/SW 0 0 **** 0 0 *** 0 0 0 0 **** 0 South 34.0 30 **** 1020 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 207 1118 211 63 340 64 0 0 0 0 0 0 exposed b 0 0 "MI 0 0 I!!!!! 0 0 null 0 0 111111 0 0 walls and c 0 0 nun 0 0 111111 0 0 nun 0 0 IIIIII 0 0 partitions d 0 0 llllll 0 0 win 0 0 win 0 0 111111 0 0 e 0 0 Min 0 0 IIIIII 0 0 min 0 0 111111 0 0 f 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 10 Ceilings a 16G0 2.4 1.1 195 463 219 28 67 31 33 78 37 44 105 49 b 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 C 0 0 HIM 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 d 0 0 Hull 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 IIIIII 0 0 nun 0 0 IIIIII 0 0 win 0 0 f 0 0 HMI 0 0 !!!!!! 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 0 0 IIIIII 0 0 !!!I!! 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 II!!!! 0 0 111111 0 0 111111 0 0 d perimeter 0 0 111111 0 0 IS dlSpl. d 0 0 win 0 HIM 0 win 0 for slab e 0 0 will 0 0 !!!!!! 0 0 !Ill!! 0 0 111111 0 0 floors) f 0 0 WWII 0 0 !!!!!! 0 0 Illlll 0 0 Illlll 0 0 12 Infiltration a 150 11.9 45 6770 537 0 0 0 0 0 0 0 0 0 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 10136 **** **** 407 **** **** 78 **** **** 108 **** Less external heating **** 0 **** **** 0 **** * 0 **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** 0 Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 ******** 14 Duct loss 6% 638 **** 6% 26 **** 6% 5 **** 6% 7 15 Total loss=13+14 **** 10774 **** **** 432 **** **** 83 **** **** 111 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 * 0 0 * 0 0 0 0 * 0 17 Subtot RSH gain=7+8..+12+16 **** **** 3007 **** **** 96 **** **** ****37 **** 49 Less external cooling **** *If** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** , **** 0 **** **** 0 0 0 ** Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 147 5% **** 5 5% **** 2 5% **** 2 19 Total RSH gain=(17+18)*PLF 1.00 **** 3154 1.00 **** 100 1.00 **** 39 1.00 **** 52 20 Air required(cfm) 108 136 4 4 1 2 1 2 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. -: -Pk��11,, r- htsoftm 9 2018-Jun-11 10:55:10 - w 9 Ri ht-Suite®Universal 2017 17.0.16 RSU25116 Page 3 AWN ...tt.langeworthy\Documents\York\SCOTT ROWLAND.rup Calc=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: ROWLAND s ,t -tr Entire House Daate: Jun 11,2018 SCOTT ROWLAND Plan: ROWLAND WEST MOUNTAIN RD,QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room12 Room13 Room14 Room15 2 Length of exposed wall 13.0 ft 18.0 ft 0 ft 9.9 ft 3 Room dimensions 13.0 x 7.0 ft 11.0 x 7.0 ft 1.0 x 53.5 ft 1.0 x 126.5 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 117 **** **** 162 **** **** 0 **** **** 90 **** **** Exposed b 0 0 IIIIII **** **** IIIIII **** **** IIIIII **** **** mill **** **** walls and c 0 0 IIIIII **** **** 111111 **** **** 111111 **** **** I III II **** **** partitions d 0 0 111111 **** **** IIIIII **** **** Him **** **** Him **** **** e 0 0 111111 **** **** IIIIII **** **** Him **** **** Him **** **** f 0 0 Him **** **** min **** **** HMI **** **** 111111 **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** 10 397 **** 0 0 **** 10 397 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 10 **** 680 0 **** 0 10 **** 680 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 21 696 131 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 96 518 98 152 821 155 0 0 0 80 432 82 exposed b 0 0 IIIIII 0 0 111111 0 0 HIM 0 0 nnn 0 0 walls and c 0 0 111111 0 0 in in partitions d 0 0 111111 0 0 win 0 0 111111 0 0 111111 0 0 A l 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 win 0 0 null 0 0 win 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 • 10 Ceilings a 16G0 2.4 1.1 91 216 102 77 183 86 54 127 60 127 301 142 b 0 0 null 0 0 111111 0 0 IIIIII 0 0 nnn 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 nnn 0 0 d 0 0 111111 0 0 winwin0 0 winwin0 0 win 0 0 e 0 0 111111 0 0 will 0 0 min 0 0 win 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 0 0 win 0 0 111111 0 0 111111 0 0 111111 0 0 perimeter c 0 0 111111 0 0 111111 is displ. d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 mil 0 0 111111 0 0 111111 0 0 floors) f 0 0 IIIIII 0 0 IIIIII 0 0 null 0 0 111111 0 0 12 Infiltration a 150 11.9 21 3159 251 10 1504 119 0 0 0 10 1504 119 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8.,+11+12 **** 4589 **** **** 2905 **** **** 127 **** **** 2634 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 289 **** 6% 183 **** 6% 8 **** 6% 166 **** 15 Total loss=13+14 **** 4878 **** **** 3088 **** **** 138 **** **** 2800 **** 16 Int.gains: People© 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 582 **** **** 1041 **** **** 60 **** **** 1023 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 28 5% **** 51 5% **** 3 5% **** 50 19 Total RSH gain=(17+18)*PLF 1.00 **** 611 1.00 **** 1092 1.00 **** 63 1.00 **** 1073 20 Air required(cfm) 49 26 31 47 1 3 28 46 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. WI'- htSOftm 2018-Jun-11 10:55:10 AL-. 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4 ACC ...tt.langeworthy\Documents\York\SCOTT ROWLAND.rup Calc=MJ7 Front Door faces: N 301.5-1-3.2 RC-0404-2018 �E � � �t \\ Rowland, Scott &Jodi BIRCH POSTED D E C� E a d E I HAVE PERSONALLY MEASURES THE[DISTANCE \ 757 W. Mountain Road FROM T E PROPERTY LINES TO THE SFD w/wood stove 2160 s.f., Gar. 595 s.f. PROP ST UR (S)OR SIGN(S) �Z°�\\\\ JUN 2 6 2018 �,,� �,-mod%� y,� --''� ✓ DATE —OD(ATURE UAV5*F 1 $ \\ VISrAP — TOWN OF QUEENSBURI BDOK 5264 PAGE—BUILDING&CODES k 71 11 tip18 r wOs A(T o�\\\ G c 7Hf0V0 RA*5ON So^OAK \ 511°� \ 1 BOOK 124C PAGE 215 1 TAX ID.500.1-1-20.2 11 CIRF 933•1 3 i N 11°yg 56„$ 1�05 50..E01- 1 y�o bl PG -(o p p rp1„ 1 � CIRF CIRF 11 ��von�#\ P 69-00' "�'� 5c P \\\ \\ \\\ \\\ \ !ANDS A4P \ LAN05 N1 \ LAND5 AW 144 785 Ft w 412.625gR 5F1ED g "PINE \ ROBERTD/STEPANO \ M/LF/A@N/LHOLS \ Gl�NA[D CR055 GARAGE BOOK/224 PAGE60 \ BOOK//00 PAGE/3C BOOK 991 PAGF326 1000.235gR ® 1� `\ TAX10.30/.5-/S \ TAY/D.301.5-1-6 \\ TAX/0.301.5-1-7 \�I� IAWD5 AYP 5HED2.135gft \ UE5L Al.HAVILANO \ \ \ I10USE \� . BOOKG59PAGE/31 \ \ \ 0 p TAX/D.30/.5-1-4 \ \ \ / 678.995gFt ; •N ?If \\ \\ \\ NPi+y A< POOL AREA rn \� I � ° �• \ \ \ L4NOSW / �, z552.045gPc .PPG BPP rEVAc �UTP NM55-I BOOK 52/PAGE55 \ \ \ TAX ID.30/.5-/-1 •\ 5D LL \ H6.9DHESgr4 .,#,1 ROAD R.O.Wp'ROAr C1 S290' 1s IPF UTP \\ \\\ \ — F 0 AGE _30.68__ .._.._. / ---- \ ROAD g.O.W �Q0,20-1° S 22°5316 W / // __•_•i- \ \\ \ •\ / •/. \ -------------- \IPF \\ ROAD R.O.W _ cIRF WEST MOUNTAIN ROAD --------------- \\ o �/' $i0°5 2 /./• UTP NM56 CIO CIRF� i''' ' \ /'/• IPF• -- UTP NG55 PROGRESS PRINT TAX ID #301.5-1-3 ORIGINAL AREA*4.37 ACRES PROJECT#18-009 ALL RIGHTS RESERVED.COPY OR REPRODUCTION OF THIS PLAN OR ANY PORTION NO. REVISION DATE ABL SURVEYING PLLC THEREOF IS PROHIBITED WITHOUT THE WRITTEN PERMISSION OF THE SURVEYOR. DRAWN BY M.MONTENA UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED PROPOSED 2 LOT SUBDIVISION FOR MICHAEL E.MONTFNA,SURVEYOR CHECK BY: SURVEYORS SEAL IS A VIOLATION OF SECTION 7209,SUBDIVISION 2 OF THE NEW JODI ROWLAND AND $AVON PLACE YORK STATE EDUCATION LAW. I HEREBY CERTIFY THAT THIS SURVEY MAP IS BASED ON AN ACTUAL FIELD SURVEY SOTT ROWLAND AT WEST MOUNTAIN ROAD SOUTH GLENS FALLS,NY 12803 COMPLETED MARCH 6,2018 AND THAT THIS SURVEY MAP WAS MADE BY ME OR APRIL 7,2018 SCALE 1"=40' MADE UNDER MY DIRECTION, AND CONFORMS WITH THE MINIMUM STANDARD I TOWN OF Qi1EENSEURY, WARREN COUNTY, NEW YORK •rj18-']98 2219 LS#050670 ASSOCIATION OF PROFESSIONAL BEEN SURVEYORS. Y THE NEW YORK STATE T1ERMALA$SOcLA1ESL Quality. Comfort. Satisfaction. Thermal Associates 21 Thomson Ave.Glens Falls, NY 12801 D ECEOWE5 5i8.798.5500 Fax 798.5620 Scott Rowland - FEB 1 1 2019 757 West Mountain Road TOWN OF O, JEENSBURY Queensbury, NY 12804 BUILDING&CODES 518-683-3410 We, Thermal Associates, performed a blower door test on the project at 757 West Mountain Road, Queensbury, NY, to determine the air changes per hour, for Scott Rowland. The result of the test is: ( 1,400 CFM50 x 60 Minutes) / (83,880cubic ft.) = 2.43 ACH50 N 1102.4.3.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less than seven air changes per hour(ACH) when tested with a blower door at a pressure of 33.5 psf(50 Pa)as verified using instruments and procedures specified in ASHRAE/ASTM E779. The test shall be conducted by a qualified person, who shall demonstrate competence to the satisfaction of the code enforcement official for the conduct of such tests. For the purpose of this section, ACH50 shall mean air changes per hour of infiltration into a house as measured with a blower door at 50 pascals of pressure, in accordance with ASHRAE/ASTM E779. Testing shall occur after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation and combustion appliances. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed; 2. Dampers shall be closed, but not sealed, including exhaust, intake. makeup air, back draft and flue dampers; 3. Interior doors shall be open; 4. Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling system(s) shall be turned off; 6. 1-IVAC ducts shall not be sealed; and 7. Supply and return registers shall not be sealed. Adam DeVit Blower Door Tester Thermal Associates www.thermalassociates.com