Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-0327-2018
TOWN OF QUEENSBURY i Y ..; i 1 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 — Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0327-2018 Tax Map No: 308.11-1-49.22 Permission is hereby granted to: Anchor Construction For property located at: 379 LUZERNE RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Gregory Garafalo Single Family-New $120,000.00 Owner Address: 375 Luzern RD Total Value $120,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Anchor Construction 375 LUZERNE RD Queensbury,NY 12804 Plans&Specifications Single Family Dwelling 1784 s.f. Garage 728 s.f. $ 1,603.60 PERMIT FEE PAID -THIS PERMIT EXPIRES: Saturday,June 29,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before th expiration s e.) Dated at the Town Queen ury; Fri.: ne 29,2018 SIGNED BY: for the Town of Queensbury. A Director of Building&Code Enforcement t. '' ,: Office Use Oniy / •{j1-,-+y� 'lN-'. Permit#: gyp itYr (-C- 0 2- + }2z to { n 0 APPLICATION Permit rae f e Q 742 Bay Road,Queensbury, NV V804 'Epee. Fee: t j�© ! P: 518-761-8256 www .queen,.buxy.net invoice# e.)(1`- Project Location: 3 ?.1�/�r � �-a.rci q z �Q Tax Map #: ®1j-Jz1 9c Subdivision Name: lf - TOWN BD.REsOLU 0 ION 86-2013:$850 recreation fee for new dwelling uni:<s: single family, dupleLsa/two-family; . inultiplefamily, apartments,condominiums, townhouses,and/or-manufactured & modular homes, but not mobile homes. This is in addition to the permit fee(s). CONTACT INFORMATION: . e Applicant: Name(s): -Z ez-4-g- Mailing Address, C/S/Z: 7 /--UZ,� arc iaz ttSbuv U 0 i�tcJ9 Cell Ph.: _( a�A) f 19 —q 2)3 Land Line: ( ) A,./D r Email: Cam, -,_- - - r. S C? AD A fetl, M€ rL i ,34 Primary Owner(a)o Name(s): (:'r:i 12-F7C79---. 4 izez:iti\JA-- 64:4,0- - 4-L- Mailing Address, C/S/Z: S7i k z /2 f L v Sk'e,tCiI , NY 12' NJ _( ) q 7 Land Line: J C Cell Ph.: f:-0� � �- _( �t���v��.. Email: A A- -A-> ._ C4 R40.rt t-i 6 o Contractor(�1 e Name(s): AN,C1 ®P. Coc 112.c: c� �t Mailing Address, C/S/Z: G Ati-A ee .s A-F-x--- Cell Ph. _( ) - 'jcL ' Land Line: 5 74 FF J.); F 'u. '\is+f". . s l\ Email: , c - — of a-� - 'pl fr-----, ,-,�y�1 \I . - �, JUN082018 �.. O Arch itect(s)/En 0-ineer(s): I 1 ‘Iy zJ Name(s): - s J18a iP,, ' `�.i�,;.. u, �. Mailing Address, C/S/Z: ,.-,-a - - -i` Cell Ph.: _( ) Land Line: ( ) Email: Contact Person for Building & Code Compliance: 6-Z " "— k Cell Ph.: _( ,cl ) c'Li .W Land Line: ( tJY Email: Coo -ci4 nc (D 'C? CiAtin-e rya ( 1(Y faORliildina&Code Enforcement Princinle Structure Revised March 9(11 R L PROJECT_Il FORMATLQI TYPE: Commercial G ' � Residential WORK CLASS: V> Single-Family Two-Family Multi-Family(#of ) Townhouse Business Office Retail Hotel/Motel industrial/VVarehouse Garage(#ofcars ) Other(describe,._ .__ .. _..__.....____ _-___-. _.. .....__) STRUCTURE SQUARE FOOTAGE: BAR _ E ��,AARE FOOTAGE: -.=- - E 1ST I 9 T floor: `j ��' floor: 2nd floor: WA-WA- 2nd floor: 13e, 3rd floor: 1`rj A'• Total square feet: 7ag Basement(habitable space): ? ' .Total square feet: V I ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ ) g 000 2. Proposed use of the building: IZl _16 c K)T14-L- 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat (circle one): has Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning Appliances Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES NO xplain: 6. Are there any easements on the property? YES NO 7. SITE INFORMATION: ,,� a. What is the dimensions or acreage oft a parcel.? b. Is this a corner lot? YES NO c. Will the grade be changed as a resu t e construction2___. YES NO d. What is the water source? PUBLIC '- `E-` WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? CR.(O.c T al Ruildinv R(Yula Fnfnrramant • DECLARATiON: I. I acknowledge that no construction shall commence priorpkrtolosuance LA'C P,,Oid builciin t;errni. and work will be completed within a 12 month period. 2. If the work 6' not completed by the lyear epiration date the permit may be renewed: subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a t rue and compiote statement and/or description of the work proposed, that ail work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with lot zoning regulations. 4. I acknowledge that prier to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I understand that Ike are required to provide an as-built survey by a licensed land surveyor of a II newly constructed facilities prior to issuance of a certificate of occupancy. • have read and agree to the above: • • PRINT NAME: (.,-`7142-E6 _ _ SIGNATURE: DATE: ) _ • • . • • rnfip Fnfnrrpmpnt _ _ a AO; 'r -�_wSEPTIC DISPOSAL PERMIT APPLICATION Office Use Only --trt"7 `-4!: ' 742 Bay Road,Queensbury,NY 12804 Town afoncensbnoey P:518-761-8256 www.queensbury.net Permit#: Tax Map ID#: Permit Fee:$ ;Invoice#: Project location:. 319 LA Zi- get Septic Variance? Yes No Primary Owner(s) 6 ac Q 4 i 6 t yk G gveiet.,F-a`� Mailing Address S75- ctz, P`r,-5I. gd, au, „ bc.f,r1 il I Zq. Phone & Email 6.-7A-P--gl---F-A�-coSCM, R10AT'Piin»62, (D fil 6/9- Pigi-r `" 1243 J Installer/Builder C(, ? 6A-aC-7-6- A cDP_, 0im v Mailing Address 5. W1 t A-g E'v Phone & Email Engineer Mailing Address Phone & Email Contact Person for Building&Code Compliance: Ci to e, .tt t -e Phone: ,.L.;)'g--P``I 91 r 3 RESIDENCE INFORMATION: Year Built Gallons #of bedrooms X gallons per =total daily flow per day bedroom Garbage Grinder Yes g 1980 or older 150 Installed? (circle one) 1981-1991 130 Spa or Hot Tub Yes No) Installed? (circle one) 1992-Present 110 ` '`� PARCEL INFORMATION: I Topography ><. Flat Rolling Steep Slope %Slope Soil Nature X Sand Loam Clay Other Groundwater At what depth? /Q 0 lji A-ER AT - 7 ' Bedrock/Impervious material At what depth? NIA- Domestic Water Supply Municipal _Well (if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: ;-`.9 - per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: , J4F+Ae SW?)a tU a 'd . 2. 1O OS 3 7 5 kl.t'.�` ry' Tank size /,ern gallons(min.size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length /_p(3 ft.; Each Trench 5-0 ft. Seepage Pit with#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size ;#of tanks NOTES: 1.Alarm system &associated electrical work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void.I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: Gaiz_L- 7 6Fki2 (FP1_ ) DATE: 51/5) /3 SIGNATURE: .��'(�'� DATE:. / Ji 0 Town of Queensbury Building&Co Enforcement Revised March 2018 Manual S Compliance Report Job: 379 LUZERNE RD Date: Jun 13,2018. Entire House By. ANCHOR CONSTRUCTION Plan: 379 LUZERNE RD QUEENSBURY,NY 12804 Project Information For: GREG GARAFALO, ANCHOR CONSTRUCTION ECE ` E I 7 QUEENSBURY, NY 12804 • , ;• JUN 2018 Li Cooling Equipment wa g p Design Conditions Outdoor design DB: 85.0°F Sensible gain: 21726 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 5894 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 27620 Btuh Indoor RH: 50% Estimated airflow: 941 cfm • Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCHD30S41S3+HD36A3XH1+TM8X060Al2MP11+S1-1TVM4G1 Actual airflow: 933 cfm Sensible capacity: 0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 98532 Btuh Entering coil DB: 64.9°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X080B12MP11 Actual airflow: 933 cfm Output capacity: 76000 Btuh 77% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2018-Jun-13 09:32:54 A wrightsoft° Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCA ...ers\scott.langeworthy\Documents\York\ANCHOR.rup Calc=MJ7 Front Door faces: N • '�.. Form �, Residential Plans Examiner Review Form RPER1 ACCk® for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 ArConcitoringCodradosoffundia QUEENSBURY NY Header Information Contractor: ANCHOR CONSTRUCTION REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes 0 No Ei Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes ❑ No OEM performance data(heating,cooling,blower): Yes ❑ No Ei Building plan#: 379 LUZERNE Manual D Friction Rate Worksheet: Yes 0 No RD Duct distribution sketch: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: -4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,south,Northeast,Northwest,Southeast,Southwest Total heat loss: 98532 Btuh Number of bedrooms: 3 Conditioned floor area: 5352 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 grub O% RH Eave overhang depth: 0 ft Sensible heat gain: 24140 Btuh Internal shade: none <— Eave Latent heat gain: 6548 Btuh Blinds,drapes,etc. Depth Window Total heat gain: 30689 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Equipment type: Split AC Heating cfm: 933 Furnace,Heaf pump,Boiler,etc. Air Conditioner,Heat pump,etc. Cooling cfm: 933 Model: York Model: York Static pressure: 0 in H2O TM9X080B12MP11 TCHD30S41S3 Fan's rated extemal static pressure for design airflow Heating output capacity:. 76000 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 933 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP a(TEL x 100) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the buildinI plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality or Authority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist - wrightsoft Right-Suite®Universal 2017 17.0.16 RSU25116 `i Project Summary Job: 379 LUZERNE RD Date: Jun 13,2018 Entire House By: ANCHOR CONSTRUCTION • Plan: 379 LUZERNE RD QUEENSBURY,NY 12804 Pro"ect Information For: GREG GARAFALO, ANCHOR CONSTRUCTION QUEENSBURY, NY 12804 Notes: • Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 92694 Btuh Structure 20713 Btuh Ducts 5838 Btuh Ducts 1013 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 98532 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 19553 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5894 Btuh • Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) i Area(ft2) 5352 5352 Equipment latent load 5894 Btuh Volume(ft3) 48168 48168 Air changes/hour 0.70 0.40 Equipment total load 25447 Btuh Equiv.AVF (cfm) 562 321 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X080B12MP11 Cond TCHD30S41S3 AHRI ref 2008691 Coil HD36A3XH1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743063 Efficiency 95.5 AFUE Efficiency 12.5 EER, 14 SEER Heating input 80000 Btuh Sensible cooling 19600 Btuh Heating output 76000 Btuh Latent cooling 8400 Btuh Temperature rise 74 °F Total cooling 28000 Btuh Actual air flow 933 cfm Actual air flow 933 cfm Air flow factor 0.009 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2018-Jun-13 09:32:54 � , wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACCK ...ers\scott.langeworthy\Documents\York\ANCHOR.rup Cale=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: 379 LUZERNE RD Entire House Date: Jun 13,2018 By: ANCHOR CONSTRUCTION Plan: 379 LUZERNE RD QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Entire House • Room1 Room2 Room3 2 Length of exposed wall 540.0 ft 180.0 ft 180.0 ft 27.0 ft 3 Room dimensions 1.0 x 1784 ft 1.0 x 1784 ft 14.0 x 13.0 ft 4 Ceilings Condit.Option 9.0 ft d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool — TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 4860 **** **** 1620 **** **** 1620 **** **** 243 **** **** Exposed b 0 0 IIIIII **** **** Illill **** **** IIIIII **** **** IIIIII **** **** walls and c 0 0 111111 **** **** IIIIII **** **** 1111II **** **** 11 ill I **** **** partitions d 0 0 IIIIII **** **** 1 1 I I I I **** **** IIIIII **** **** 1111II **** **** e 0 0 1 1 1 H I **** **** IIIIII **** **** 111111 **** **** IIIIII **** **** f 0 0 IIIIII **** **** 111111 **** **** HIIH **** **** IIIIII **** **** 6 Windows and a 3A0 39.7 ** 235 9323 **** 50 1984 **** 0 0 **** 35 1389 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 100 **** 1900 35 **** 665 0 **** 0 20 **** 380 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 45 **** 3060 15 **** 1020 0 **** 0 15 **** 1020 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 90 **** 3060 0 **** 0 0 **** 0 0 **** 0 Harz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 84 2782 526 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 4541 24521 4632 1570 8478 1601 1620 8748 1652 208 1123 212 exposed b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 will 0 0 111111 partitions d 0 0 111111 0 0 HUH 0 0 111111 0 0 111111 0 0 0 0 111111 0 0 IIIIII 0 0 e 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 111111 0 0 f 0 0 IIIIII 0 0 111111 0 0 HUH 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 3568 8478 4003 0 0 0 1784 4239 2002 182 432 204 b 0 0 111111 0 0 111111 0 0 111111 0 0 IIIIII 0 0 C 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 d 0 0 111111 0 0 IIIIII 0 0 HUH 0 0 111111 0 0 e 0 0 IIIIII 0 0 111111 0 0 HUH 0 0 111111 0 0 f 0 0 will 0 0 111111 0 0 111111 0 0 null 0 0 11 Floors a 1910 1.7 0 1784 3083 0 1784 3083 0 0 0 0 0 0 0 (Note:room b 0 0 I I1111 0 0 111111 0 0 111111 0 0 111111 UH 0 0 perimeter c 0 0 IIIIII 0 0 111111 is displ. d 0 0 HUH 0 0 111111 0 0 0 0 1 II111 0 0 0 0 HIM 0 0 IIIIII 0 0 for slab e 0 0 I IUH 0 0 111111 0 0 HIM 0 0 111111 0 0 floors) f 0 0 nnn 0 0 IIIIII 0 0 HUH 0 0 111111 0 0 12 Infiltration a 140 11.1 319 44507 3532 50 6976 554 0 0 0 35 4883 388 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 92694 **** **** 20520 **** **** 12987 **** **** 7827 **** Less external heating **** 0 **** **** 0 **** **** p **** **** p **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 5838 **`* 6% 1292 **** 6% 818 **** 6% 493 **** 15 Total loss=13+14 **** 98532 **** **** 21813 **** **** 13805 **** **** 8320 **** — 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 20713 **** **** 3840 **** **** 3654 **** **** 2204 Less extemal cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 1013 5% **** 188 5% **** 179 5% **** 108 I 19 Total RSH gain=(17+18)*PLF 1.00 **** 21726 1.00 **** 4028 1.00 **** 3833 1.00 **** 2312 20 Air required(cfm) 933 933 207 173 131 165 79 99 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. — 2018-Jun-13 09:32:54 .` wrightSOftm Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 ACC ...ers\scott.langeworthy\Documents\York\ANCHOR.rup Calc=MJ7 Front Door faces: N a Right-J®Worksheet Job: 379 LUZERNE RD Entire House Date: Jun 13,2018 ANCHOR CONSTRUCTION Plan: 379 LUZERNE RD QUEENSBURY,NY 12804 MANUAL J:7th Ed. - 1 Name of room Room6 Room7 Room8 Room9 2 Length of exposed wall 8.0 ft 33.0 ft 0 ft 47.0 ft 3 Room dimensions 9.0 x 8.0 ft 14.0 x 15.0 ft 5.0 x 8.0 ft 1.0 x 726.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool - TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Gig (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 72 **** **** 297 **** **** 0 **** **** 423 **** **** Exposed b 0 0 111111 **** **** IIIIII **** **** IIIIII **** **** IIIIII **** **** walls and c 0 0 Him **** **** IIIIII **** **** I I I I I I **** **** II III I **** **** partitions d 0 0 mill **** **** III III **** **** IIIIII **** **** IIIIII **** **** e 0 0 IIIII1 **** **** Illlli **** **** 111111 **** **** IIIIII **** **** f 0 0 111111 **** **** 111111 **** **** IIIIII **** **** II11II **** **** 6 Windows and a 3A0 39.7 ** 15 595 **** 30 1190 **** 0 0 **** 60 2380 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** - 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 30 **** 570 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 15 **** 1020 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 30 **** 1020 0 **** 0 30 **** 1020 Harz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 63 2087 :394 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 57 308 58 267 1442 272 0 0 0 300 1620 306 exposed b 0 0 Hum 0 0 111111 0 0 111111 0 0 IIIIII 0 0 walls and c 0 0 Hull 0 0 111111 partitions d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 IIIIII 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 IIIIII 0 0 111111 0 0 nnn 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 72 171 81 210 499 236 40 95 45 726 1725 1315 b 0 0 null 0 0 111111 0 0 111111 0 0 Ilnn 0 0 e 0 0 111111 0 0 111111 0 0 IIIIII 0 0 111111 0 0 d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 0 0 IIIIII 0 0 IIIIII 0 0 win 0 0 111111 0 0 perimeter c 0 0 111111 0 0 111111 is displ. d 0 0 111111 0 0 null 0 0 111111 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 IIIIII 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 1111111111110 0 111111 0 0 nnll 0 0 12 Infiltration a 140 11.1 15 2093 166 30 4186 332 0 0 0 123 17161 1362 Ventilation o 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 3167 **** **** 7317 **** **** 95 **** **** 24973 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 199 **** 6% 461 **** 6% 6 **** 6% 1573 **** 15 Total loss=13+14 **** 3366 **** **** fa( **** **** 101 **** **** 26546 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 1325 **** **** 1860 **** **** 45 **** **** 4467 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 65 5% **** 91 5% **** 2 5% **** 218 19 Total RSH gain=(17+18)*PLF 1.00 **** 1390 1.00 **** 1951 1.00 **** 47 1.00 **** 4(185 20 Air required(cfm) 32 60 74 84 1 2 251 201 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. - wri 2018-Jun-13 09:32:54ghtsOft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 ACCA ...ers\scott.langeworthy\Documents\York\ANCHOR.rup Calc=MJ7 Front Door faces: N 1 Rig ht-J®Worksheet Job: 379 LUZERNE RD Entire House Date: Jun 13,2018 ANCHOR CONSTRUCTION Plan: 379 LUZERNE RD QUEENSBURY,NY 12804 . MANUAL J:7th Ed. ,- 1 Name of room Room10 Room11 Room12 Room13 2 Length of exposed wall 23.0 ft 0 ft 9.0 ft 20.0 ft 3 Room dimensions 13.0 x 10.0 ft 6.0 x 4.0 ft 1.0 x 81.0 ft 7.0 x 13.0 ft I 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool I TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 207 **** **** 0 **** **** 81 **** **** 180 **** "*** Exposed b 0 0 IIIIII **** **** nun **** **** IIIIII **** **** III111 **** **** walls and c 0 0 IIIIII **** **** III 1II **** **** 111111 **** **** IIIIII **** **** partitions d 0 0 IIIIII **** **** 111III **** **** II" **** **** Il1III **** **** e 0 0 Him **** **** 111111 **** **** II" **** **** IIIIII **** **** f 0 0 Him **** **** III"1 **** **** IIIIII **** **** IIIIII **** **** 6 Windows and a 3A0 39.7 ** 15 595 **** 0 0 **** 0 0 **** 15 595 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 0 0 0 0 0 0 0 0 d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 15 **** 285 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 * 0 0 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 0 **** 0 15 **** 510 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 21 696 131 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 171 923 174 0 0 0 81 437 83 165 891 168 exposed b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 111111 0 0 111111 partitions d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 130 309 146 24 57 27 81 192 91 91 216 102 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 C 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 I IIIII 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 win 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 (Note:room b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 perimeter c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 is displ. d 0 0 Win 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 nnn 0 0 111111 0 0 111111 0 0 12 Infiltration a 140 11.1 36 5023 399 0 0 0 0 0 0 15 2093 166 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 **** 7546 **** **** 57 **** **** 630 **** **** 3795 **** Less external heating **** 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer **** 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution **** 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 475 **** 6% 4 **** 6% 40 **** 6% 239 **** 15 Total loss=13+14 **** 8021 **** **** 61 **** **** 670 **** **** 4034 *"** { 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 **** **** 1135 **** **** 27 **** **** 174 **** **** 946 Less external cooling **** **** 0 **** **** 0 **** **** 0 **** **** 0 Less transfer **** **** 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution **** **** 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 56 5% **** 1 5% "*** 8 5% **** 46 I 19 Total RSH gain=(17+18)*PLF 1.00 **** 1191 1.00 **** 28 1.00 **** 182 1.00 **** 993 I I 20 Air required(cfm) 76 51 1 1 6 8 38 43 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft® 2018-Jun-13 09:32:54 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3 ACC ...ers\scott.langeworthy\Documents\York\ANCHOR.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: 379 LUZERNE RD Entire House Date: Jun 13,2018 •ANCHOR CONSTRUCTION Plan: 379 LUZERNE RD QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room14 2 Length of exposed wall 13.0 ft 3 Room dimensions 1.0 x 228.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Area Area EXPOSURE NO. Htg Clg (ft2) Htg Clg Htg Clg Htg Clg Htg Clg 5 Gross a 12E3 5.4 1.0 117 **** **** **** **** **** **** **** **** Exposed b 0 0 null **** **** **** **** **** **** **** **** walls and c 0 0 IIIIII **** **** **** **** **** **** **** **** partitions d 0 0 IIIIII **** **** **** **** **** **** **** **** e 0 0 IIIIII **** **** **** **** **** **** **** **** f 0 0 IIIIII **** **** **** **** **** **** **** **** 6 Windows and a 3A0 39.7 ** 15 595 **** **** **** **** glass doors b 0 ** 0 0 **** **** **** **** Heating c 0 ** 0 0 **** **** **** **** d 0 ** 0 0 **** **** **** **** e 0 ** 0 0 **** **** **** **** f 0 ** 0 0 **** **** **** **** 7 Windows and North 19.0 0 **** 0 **** **** **** glass doors NE/NW 0 0 **** 0 **** **** **** Cooling E/W 68.0 0 **** 0 **** **** **** SE/SW 0 0 **** 0 **** **** **** South 34.0 15 **** 510 **** **** **** Holz 0 0 **** 0 **** **** **** 8 Other doors a 10D0 33.1 6.3 0 0 0 b 0 0 0 0 0 c 0 0 0 0 0 9 Net a 12E3 5.4 1.0 102 551 104 exposed b 0 0 IIIIII 0 0 walls and c 0 0 111111 0 0 partitions d 0 0 IIIIII 0 0 e 0 0 IIIIII 0 0 f 0 0 Him 0 0 10 Ceilings a 16G0 2.4 1.1 228 542 256 b 0 0 IIIIII 0 0 c 0 0 Him 0 0 e 0 0 IIIIII 0 0 e 0 0 IIIIII 0 0 f 0 0 IIIIII 0 0 11 Floors a 1910 1.7 0 0 0 0 (Note:room b 0 0 !mu 0 0 perimeter c 0 0 111111 0 0 is displ. d 0 0 IIIIII 0 0 for slab e 0 0 IIIIII 0 0 floors) f 0 0 will 0 0 12 Infiltration a 140 11.1 15 2093 166 Ventilation 0 0 13 Subtotal loss=6+8..+11+12 **** 3780 **** **** **** **** **** **** **** Less external heating **** 0 **** **** **** **** **** **** **** Less transfer **** 0 **** **** **** **** **** **** **** Heating redistribution **** 0 **** **** **** **** **** **** **** 14 Duct loss 6% 238 **** **** **** **** 15 Total loss=13+14 **** 4019 **** **** **** **** **** **** **** 16 Int.gains: People @ 300 0 **** 0 **** **** **** Appl. © 1200 0 **** 0 **** **** **** 17 Subtot RSH gain=7+8..+12+16 **** **** 1036 **** **** **** **** **** **** Less external cooling **** **** 0 **** **** **** **** **** **** Less transfer **** **** 0 **** **** **** **** **** **** Cooling redistribution **** **** 0 **** **** **** **** **** **** 18 Duct gain 5% **** 51 **** **** **** 19 Total RSH gain=(17+18)*PLF 1.00 **** 1087 **** **** **** 20 Air required(cfm) 38 47 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. ACCA wrightsoft 2018-Jun-13 09:ag 4 Right-Suite®Universal 2017 17.0.16 RSU25116 Page: 4 ..ers\scott.langeworthy\Documents\York\ANCHOR.rup Calc=MJ7 Front Door faces: N I 155 MAX HEAT RECOVERY VENTILATOR ; -, 0.0 ENGINEERING DATA LIFEBRERTH' j THERMALLY CONDUCTIVE, PATENTED DEFROST - - — ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 mm)OD.Balancing ports Each airstream has one centrifugal blower driven by a common PSC motor,with multiple are located on door. fan speed operations. ELECTRONICS FILTERS The DXPLO2 control included with the unit can be wall mounted in a central location of Washable air filters in exhaust and supply air streams. the home.3 wire 20 gauge(min.)100 ft length(max.). MOUNTING Four threaded inserts at corners of the cabinet designed to accept the"s"hooks and WARRANTY hanging straps supplied with the unit Units carry a lifetime warranty on the HRV core and a 5 year replacement parts warranty. OPTIONAL ACCESSORIES: er Hood TechGrille Weather 99-EAG4 Terminator Wireless 20/40/60 99-185 99-EAGS Fitting Min Timer 99-186 99-TM4 99-DET02 e'-% 99-187 / f 99-EAG6 99-EAGB �` 99-TM5 f \�:` 99 TM6 , ";:— -....." 451 ' LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DET01-Lifebreath 20/40/60 Minute Timer FEATURES 99-DXPLO2 99-BCO2 99-BC03 99-BC04 Initiates high speed Ventilation for 20,40 or 60 ✓ minutes.3 wire connection. 5 speed fan operation on each mode 99-DET02 2 speed fan operation(Low/High) ✓ ✓ Wireless Lifebreath 20/40/60 Minute Timer Continuous low speed fan operation ,/ Initiates high speed Ventilation for 20,40 or 60 minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat ✓ V V ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen ✓ 99-RX02-Wireless Lifebreath Repeater LED status indicator lights V V V Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation V V main control and 99-DET02.Install at halfway ✓ ✓ point between timer and main wall control if timer . Continuous Recirculation is out of range. 20 0N/40 OFF V o V 11 i 10 ON/50 OFF , 5- v:"' 20 ON/40 Recirculation ✓ V V --- , \\41 ,- , 20/40/60 min.High speed override button ✓ 99-DXPLO2 99-DET02 Compatible with 99-DET02 Wireless Timer V V V V a/ 3 wire connection V V V V LIFEBREfl TH° as Indoor Air Systems 1SSMAX(01-01-18) vvuvw.lifebreath.com a _ . — r Tr l55 MAX HEAT RECOVERY VEN I „ATOP - .' PERFORMANCE (HVI CERTIFIED) L/FEBRERTH° It 0.1(25) 0.2(50) 0.3(75) 0.4(100) 0.5(125) 0.6(150) 0.7(17S) ELECTRICAL SPECIFICATIONS IN.W.G.(PA) CFM(L/s) CFM(L/s) CFM(L/s) CFM(L/s) CFM(L/s) CFM(L/s) CFM(Vs) VAC @ 60Hz 115 .....Jupply Airflow 184(87) 163(77) 146(69) 132(62) 115(54) 92(43) 60(28) Watts/Low Speed 66 Gross Supply Airflow 188(87) 166(78) 149(70) 134(63) 117(55) 94(44) 61(29) Watts/High Speed 118 Gross Exhaust Airflow 239(113) 228(107) 212(100) 193(91) 172(81) 150(71) 126(60) Amp Rating 1.4 Sensible Effectiveness(ASE) 32°F(0°C) 84% 1B0 WEIGHT: @ 59 CFM(28 Us) 71 LBS(32 KG) Sensible Efficiency(SRE) 160 SHIPPING WEIGHT: @ 59 CFM(28 Us) 32°F(0°C) 75% 73 LBS(33 KG) E 140 Sensible Efficiency(SRE) 32°F(0°C) 75% @ 64 CFM(30 Us) 120 Sensible Efficiency(SRE) NOTE: 13°F[25°C) 72% loci @ 64 CFM(30 Us) i "110 Front clearance of 25 in.(635 mm)is B0 recommended for servicing unit.All ducts S�c use 6 in.(152 mm)round collars.Balancing V�' ISO ®FIRM 60 dampers are located in all air streams. CoreernsIoULSIenda CERTIFIED REGISTERED I I I I I I I I 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Static Pressure(in w.g.) • DIMENSIONS FRONT VIEW TOP VIEW Filter 1111r ' 14 3/4 in.(375 mm) Recirculating Defrost 111171 !"7� Damper 'It ) — -Removablik' \'4t941/ - 151 Blower IA Heat - Motor I . Stale air to outside Recovery __ Core i C. All i Fresh air from outside A41111+ Stale air from inside � eD Fresh air to inside SRounin.(d152Collars mm) I' — 33 5/8 in.(854 mm) ,I •v v • ' Date: WARRANTY Contractor: Units carry a lifetime warranty Tag: on the HRV core and a s year replacement parts warranty. Project. Qty: Supplier: Engineer: Quote#: All units conform to CSA and LPL standards OS Control: Submitted By: LIFEBRE/ / THT II Indoor Air Systems Timer: Timer Qty: 155MAX(01-01-18) www.lifebreath.com REScheck Software Version 4.6.5 ci. i ' Compliance Certificate REVIEWED FOR Project ENERGY CODE COMPLIANCE Energy Code: 2015 IECC Location: Glens Falls, New York Construction Type: Single-family Project Type: • New Construction Conditioned Floor Area: 0 ft2 Glazing Area 14% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: a 371 L t2 a ice. ' a491-zur 1 ` LCL!1 [, Compliance:Passes using UA trade-off Compliance: 1.8%Better Than Code Maximum UA: 217 Your UA: 213 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. • It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Flat Ceiling or Scissor Truss 1,688 49.0 0.0 0.026 44. Wall 1:Wood Frame, 16" o.c. 1,275 21.0 0.0 0.057 63 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 101 0.280 28 Door 1: Glass 32 0.290 9 Door 2: Glass 20 0.170 3 Door 3: Glass 20 0.170 3 Basement Wall 1: Solid Concrete or Masonry 1,376 21.0 0.0 0.046 63 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is co sistent with the building plans,specifications, and other calculations sub itted with the permit application.The proposed buildin as been desi ned to meet the 2015 IECC requirements in REScheck Ver ' n 4.6.5 and to comply with the mandatory requireme listed in the check Inspecti Checklist. T Namd-Title at e Date - Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 1 of 9 M ista ke.rc k 7 t 0 REScheek Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, R Construction drawings and I Complies 103.2 documentation demonstrate iDDoes Not [PR1]1 energy code compliance for the ig building envelope.Thermal f]Not Observable envelope represented on LNot Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate 'LiDoes Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. []Not Observable 1..4.) Systems serving multiple l]Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 1 - 302.1, 'Heating and cooling equipment is Heating: Heating: omplies ,_ at ANa frt.- 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Si j Manual J or other methods Cooling: Cooling: [Not Observable approved by the code official. Btu/hr Btu/hr '❑Not Applicable ` 2 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date:' 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 2 of 9 M ista ke.rc k i e .. Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &Req.ID 402.1.1 Conditioned basement wall i R- ..1 - R- -omplies See the Envelope Assemblies [F04]'- insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification may need to occur during ['Not Observable • Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall I omplies [F05]1 insulation installed per I I❑Does Not manufacturer's instructions. !❑Not Observable ® s (❑Not Applicable 402.2.9 Conditioned basement wall G) ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. ,g distance from top of wall. ❑Not Observable ONot Applicable 303.2.1 A protective covering is installed omplies [F01l]2 ;to protect exposed exterior ElDoes Not 1 insulation and extends a9. I minimum of 6 in.below grade. ;❑Not Observable j❑Not Applicable 403.9 2 ;Snow-and ice-melting system Complies [F012] controls( installed. i❑Does Not 'i ❑Not Observable } ;❑Not Applicable Additional Comments/Assumptions: _ 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 3 of 9 M ista ke.rc k Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, "Glazing U-factor(area-weighted U- r Z93 U- r1.Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable ' [FR2]1 ❑Not Applicable , 303.1.3 U-factors of fenestration products ❑Complies [FR4]'- are determined in accordance ❑Does Not with the NFRC test procedure or t - taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier omplies [FR23]1 installed per manufacturer's - ' - - i❑Does Not instructions. ,❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ' - - - ❑Complies [FR20]1 is listed and labeled as meeting l❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440! S to ` ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code 1 ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures! eomplies [FR1612 sealed at housing/interior finish ❑Does Not and labeled to indicate 5_2.0 cfm ,_ _ - .. . . ;leakage at 75 Pa. j ❑Not Observable ■Not Applicable • 403.3.1 Supply and return ducts in attics i Complies [FR12]1 insulated>= R-8 where duct is ;❑Does Not t >=3 inches in diameter and>= R-6 where<3 inches.Supply and ❑Not Observable • return ducts in other portions of ❑Not Applicable the building insulated >=R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.5 Building cavities are not used as eComplies [FR15]3 ducts or plenums. _ . ,❑Does Not ❑Not Observable ❑Not Applicable 403.4 1 HVAC piping conveying fluids R- R- ❑Complies [FR17]z ;above 105°F or chilled fluids ❑Does Not below 55°F are insulated to>_R- '❑Not Observable lot Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not Lg ❑Not Observable lot Applicable 403.5.3 Hot water pipes are insulated to R- R- iterComplies [FR18]z j>R-3. ❑Does Not 9) ❑Not Observable ❑Not Applicable 403.6 ;Automatic or gravity dampers area mplies [FR19]2 installed on all outdoor air ❑Does Not ;intakes and exhausts. j ;❑Not Observable ❑Not Applicable • Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 4 of 9 M ista ke.rck 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 5 of 9 M ista ke.rck Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 !All installed insulation is labeled _ . Complies [IN13]2 or the installed R-values i0Does Not provided. 'ONot Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least i of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ONot Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel Applicable 303.2 Wall insulation is installed per jC`omplies [IN4]i manufacturer's instructions. 10Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 6 of 9 M ista ke.rck • • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R.-4 d S R- . complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.E ❑ Steel ❑ Steel ❑Not Observable [FIl]1 ,ONot Applicable 1 1 E 303.1.1.1, Ceiling insulation installed per , e= omplies 303.2 manufacturer's instructions. I LIDoes Not [FI2]1 Blown insulation marked every j { 300 ft2. ;❑Not Observable ❑Not Applicable 402.2.3 ;Vented attics with air permeable - omplies [F122]' iinsulation include baffle adjacent -- {❑Does Not to soffit and eave vents that I a extends over insulation. {❑Not Observable Not Applicable 402.2.4 Attic access hatch and door R- R- °.�'complies ° [FI3]1 insulation?R-value of the ❑Does Not adjacent assembly. ['Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= agclmplies [FI17j1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 Complies [FI4]'- cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air [Not Observable handler @ 25 Pa.For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]'- determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ,,blot Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated © omplies [F124]1 by manufacturer at<=2%of f❑Does Not design airflow. i❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats arCrOmplies [FI9]' installed for control of primary ! ;❑Does Not heating and cooling systems and ; • - ; initially set by manufacturer to [Not Observable code specifications. I ❑Not Applicable 403.1.2 'Heat pump thermostat installed ❑Complies [FI10]' on heat pumps. ( - - - - ❑Does Not ❑Not Observable t Applicable 403.5.1 ;Circulating service hot water - - - -- - ?❑Complies [Fill]' systems have automatic or DDoes Not i accessible manual controls. '1 Not Observable ' .t Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 7 of 9 Mistake.rck 2 d ' Section # Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions &Req.ID Value Value 403.6.1 ;All mechanical ventilation system I Cun�plies [FI25]2 ;fans not part of tested and listed I Does Not HVAC equipment meet efficacy 1 ;and airflow limits. ;❑Not Observable 1 i I❑Not Applicable 403.2 ;Hot water boilers supplying heat 1 ;❑Complies [FI26]2 ;through one-or two-pipe heating '❑Does Not systems have outdoor setback control to lower boiler water ;❑Not Observable `.temperature based on outdoor t Applicable temperature. 1 403.5.1.1 Heated water circulation systems 1 ;❑Complies [FI28]2 have a circulation pump.The ❑Does Not ;system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe.Gravity and thermos- Groot—Applicable syphon circulation systems are f 'not present. Controls for 1 - - - circulating hot water system i pumps start the pump with signal i for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and ;no demand for hot water exists. 403.5.1.2 Electric heat trace systems '❑Complies [FI29]2 comply with IEEE 515.1 or UL I ❑Does Not 515.Controls automatically j adjust the energy input to the _ ;❑Not Observable heat tracing to maintain the eigkfet Applicable desired water temperature in the i piping. 403.5.2 Water distribution systems that ElComplies [FI30]2 have recirculation pumps that ❑Does Not pump water from a heated water I ;❑Not Observable supply pipe back to the heated water source through a cold ! i.t Applicable water supply pipe have a 1 demand recirculation water !system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 !tested in accordance with CSA i ❑Does Not B55.1.Potable water-side pressure loss of drain water heat DNot Observable recovery units<3 psi for I of Applicable ;individual units connected to one 'or two showers.Potable water- jside pressure loss of drain water heat recovery units<2 psi for individual units connected to ;three or more showers. 404.1 75%of lamps in permanent j j4 Complies [FI6]1 ;fixtures or 75%of permanent ,,Citilies Not fixtures have high efficacy lamps. ❑Not Observable Does not apply to low-voltage lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have Complies [FI23]3 no continuous pilot light. I ❑❑Does Not ,, � I❑Not Observable i❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 8 of 9 M ista ke.rck s r = Section # Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions &Req.ID Value Value 401.3 Compliance certificate posted. omplies [FI7]2 ;ODoes Not ONot Observable I Not Applicable 303.3 Manufacturer manuals for Complies IFI18]3 mechanical and water heating ElDoes Not systems have been provided. ❑Not Observable DNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/18/18 Data filename: C:\Documents and Settings\Greg\My Documents\REScheck\379 Luzerne Rd Final Page 9 of 9 M ista ke.rck -J --� . _ - - ,--M - _�_-_--- -" �_0- -�-- --� - � � � -- s - -- --- � � __p.o-____: - � — --- - -- � j@�_ -- �. �� - - - - -- - - - � � _ _ HER TN[AL ksociAns Thomson Avenue Glens Falls, NY 12801 518.798.550o Fax'518.798.5620 Heating & Cooling Specialists www.thermalassociates.com Greg Garafalo 379 Luzerne Rd Queensbury, NY 12804 518.894.9283 We,Thermal Associates,performed a blower door test at the project at 379 Luzerne Rd. Queensbury, NY 12804 to determine the air changes per hour,for Anchor Construction on June 29th,2021. Testing procedure performed as per ASTM E779 The result of the test is:(920 CFM50 x 60 Minutes)/(33,900 cubic feet) _ 1.62 ACH50 Test conditions were as follows: 86F outside air temperature 74F inside air temperature -0.1 PA baseline pressure -50.8-51.6 PA testing pressure N1102.4.3.1 Testing option.Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less than seven air changes per hour(ACH)when tested with a blower door at a pressure of 33.5 psf(50 Pa)as verified using instruments and procedures specked in ASHRAE/ASTM E779.The test shall be conducted by a qualified person,who shall demonstrate competence to the satisfaction of the code enforcement official for the conduct of such tests.For the purpose of this section,ACH50 shall mean air changes per hour of infiltration into a house as measured with a blower door at 50 pascals of pressure,in accordance with ASHRAE/ASTM E779.Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing,electrical,ventilation and combustion appliances. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed; 2.Dampers shall be closed,but not sealed,including exhaust,intake, makeup air,back draft and flue dampers, 3.Interior doors shall be open; 4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling system(s)shall be turned off, c 6.HVAC ducts shall not be sealed;and 7.Supply and return registers shall not be sealed. Adam DeVit Blower Door Tester Thermal Associates www.thermalassociates.com