2008-252 TOWN OF QUE E NSBURY
'�►' 2 2 742 Bay Road,Queensbury,NY 1 $04 590 (518)761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number. P20080252 Date Issued: Friday, August 08, 2008
This is to certify that work requested to be done as shown by Permit Number P20080252
has been completed.
Tax Map Number. 523400-301-005-0001-053-000-0000
Location: 7 NOBLE Way
Owner JOSEPH J. & SUZAN MARCELLETTI
Applicant: JOSEPH J. & SUZAN MARCELLETTI
This structure may be occupied as a:
Work Shop
By Oder of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
•
BUILDING PERMIT
Permit Number: P20080252 Application Number: A20080252
Tax Map No: 523400-301-005-0001-053-000-0000
Permission is hereby granted to: JOSEPH J. & SUZAN MARCELLETTI
For property located at: 7 NOBLE Way
in the Town of Queensbury,to construct or place
- at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JOSEPH J. & SUZAN MARCELLET' Work Shop
7 NOBLE Way p $10,000.00
QUEENSBURY,NY 12804-0000 Total Value $10,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2008-252
504 sq. ft. workshop
$50.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,May 30,2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To n of eens ; i May 30, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
E"E"C"E"it'll ;
3° 1 �! OFFICE USE ONLY , -_ E ill
TAX MAP NO. PERMIT NO. O:1 _.� 7 )��.+-,
f MAY 2 8 2008IL»
FEES: PERMIT RECREATION ENGINEERING % ; ,
(If applicable) _ :: R TOWN OF QUEENSB;URY e_.._.a:ese<averd_Pd=e____,.e.,_oP,.e_°e_asre..,,_doaao.,. _._.e°a_..ee.e,. � ,."AH1lIt1�7N"V�i✓C�DES
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FORi, CONSTRUCTION.
APPLICANT/BUILDER: , �$0 s9 N eca Z,Z,\\cN : OWNER: S t .e-
ADDRESS: �O j�� �.. )pt- ,a,�j ��� ADDRESS: i�
PHONE NOS. ?15"'C�V09 Rik 7 q(0 )Io', Cat PHONE NOS. i i
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: Wine\''VP PHONE:77 6p-a(0 j
LOCATION OF PROPERTY: 7 o B k 6Ca 5� _ N.Ro 1
SUBDIVISION NAME: th ,,�s Co s 'k
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
APPLY TO YOUR O ce d o r
PROJECT O Q O O Cl) co w
I- W JO LL Ill
a 2
oQ �U
z_
Ili
< < c-co N co 0 u O L~L O..I o
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY(NO. )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3) •
OTHER \O C X 50� vc-
�-k, 3ft
--:7!';) Tory 11 of Qzteensbury • Cornrrruniti/Development Office • 742 Bay Road, Queensbur1/, NY 12804
¢^c 06?„----2c2_,_
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
` 1
ESTIMATED CONSTRUCTION COSY 1D ilia) FUEL TYPE: 1 G
HEAT TYPE? N\CA *HOW MANY FIREPLACE(S) i \0( AND/OR WOODSTOVES(S): A))CI
ZONING CATEGORY: ,Dfe.k Pc ARE THERE WETLANDS ON THIS SITE? &0
IS THIS A HISTORIC SITE? too
PROPOSED USE OF BUILDING OR ADDITION: ./3 0`"\C- VO f)
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 0 0
ARE THERE EASEMENTS ON PROPERTY? j%) 0
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I
certify that the application, plans, and supporting materials are a true and complete
statement/description of the work proposed, that all work will be performed in accordance with the
NY State Building Codes, local building laws and ordinances, and in conformance with local zoning
regulations. I acknowledge that -•or to occupying the facilities proposed, I or my agents will obtain
a certificate of occ loamy. I al-o u •erstand that I/we are required to provide an as-built survey by
a licen ed lane; su = or of all -wly konstructed facilities prior to issuance of a certificate of
occupa y.
I haver and re- . e above.
Signed iV \ -/-
"' _
Director of Building & Codes: 761-8256 (for questions QUESTIONS? CALL 761-8256 OR EMAIL
regarding Building Permits, construction codes or septic codes(a,queensbury.net
systems)
VISIT OUR WEBSITE FOR MORE INFORMATION
Zoning Administrator: 761-8218 (for questions regarding www,queensbury.net
required permits, the permit process, application requirements or to
schedule an appointment)
, 4` 4
This application/proposed action described , ff Permission is hereby granted to the above
herein is found to be in accordance with the „ , Applicant to erect or alter the building described
zoning Laws of the Town of Queensbury. ; ; herein in accordance with said Application:
,
, f
, ; 9
H
" �
a ZONING APPROVAL DATE a 41 09 vAlPerawair
i BUILDING&CS i`S APPROVA TE
, ff
f`:`. . ;:, Town of Queensbury • Community Development elopment Office, • 742 Bay Road, Queensbury, NY 12804
Queensbury Building & Code Enforcement - Residential Fi afl Inspection -- 1
Office No. (518)761-8256 Arrive: 1.-el-am/pm art: am/pm
Date Inspection request received: Inspectot's Initials: ,10-
NAME: if del-t PERMIT#:
LOCATION: h jj(2 DATE: 5
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors t main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:1 50 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.fit.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door doser
Duct work Sealed properly
Gas Logs in Sealed I %closure
Final Electrical
Final Survey Plot PlaW
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O(Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\lnspectiion Forms\Residential Final Inspection Form revised_100405.doc;Revised
January 7,2008
71L
Rough Plumbing / Insulation Inspectiori Report
Office No. (518) 761-8256 Date Inspecti n request received:
Queensbury Building & Code Enforcement Arrive: C ' am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspectdr's lnitials�.l
NAME: ri‘; . / , PERMIT#:
LOCATION: /J /
� 0?-2Ca_INSPECT ON: -7 -/l2_-/;
•
TYPE OF STRUCTURE: CYO )k$DA
Y N N/A
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 '/2 inch minimum Drain Size
WashinglAachine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
F/kt C 'kLC '
50 P.S.I r 15 minutes Check /
Insulatio Residential Check/Commercial
Tyv r Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed (No Insulation)
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspecti n requ - }-•iv
Queensbury Building &Code Enforcement Arrive:. 1,Ab a ►r• D- •-rt: ` a /pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: MCrC //.e79 f P RMIT#: 23 _
LOCATION: -7 ph, NSPECT ON:
TYPE OF STRUCTURE:
r� Y N N/A
Framing COMMENTS:
ss 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
ft. or less on center
Ice and water shi d 24 inches from wall
lr • , , 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:1Building&Codes Forms-OLDlBuilding&Codes'nspection FormsFFraming Firestopping inspection Reportdoc Revised January 7,2008
Foundation Inspection Report
Office No.(518)761-8256 Date Ins ecti9krequest received:
Queensbury Building&Code Enforcement Arrive: :. `j am/p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: -rCe-6 (€Jf7 PERMIT#: 0
LOCATION: 7 INSPECT ON: —320
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Fours ati•. A :11,our
CReinfor in Place
1+om: `owels sr Keyway in place
Found•t,•n D. I .proofmg
Foundation ,l aterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
tjeaal4es61/11
(37 Foundation Inspection Report
Office No.(518)761-8256 Date Inspection quest received:
Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's�Initials:
��
NAME: , ce k. . S
PERMIT#: 067" 2
LOCATION: ///v d. _ 1J INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place ;Z�.
The contractor is responsible Tor
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM