Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-0426-2018
TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0426-2018 Date Issued: Tuesday, May 7, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-0426-2018 Tax Map Number: Location: Owner: 266.4-1-3 1049 State Rte 149 Thelma Ilsley, Dwight Ilsley Hilltop ConstructionApplicant: This structure may be occupied as a: Single Family Dwelling 1880 s.f. Garage 1152 s.f. ( 2nd floor storage)By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement F TOWN OF QUEENSBURY iN, 742 Bay Road;Queensbury,NY 12804-5904 (518)761-8201 ` _` =x- Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0426-2018 Tax Map No: 266.4-1-3 Permission is hereby granted to: For property located at: 1049 State Route 149 In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Thelma Ilsley Single Family-New $368,000.00 Owner Address: 35 BIRDSALL RD Total Value $368,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Hilltop Construction 51 Crowley RD Hudson Falls,NY 12839 Plans&Specifications Single Family Dwelling 1880 s.£ Garage 1152 s.f.(2nd floor storage) $ 1,759.60 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,August 1,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before i e ex irati•1 s a,-.) / . Dated at the To of Qu b 1 e S'-� .ay,August 1,2018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement • t Office Use Only Permit#: R' 4<goT PRINCIPLE STRUCTURE PERMIT APPLICATION Permit Fee:$ 5� 3 '1'�o pG 742 Bay Road.Queensbury, NV t2804 *Rec. Fee:$ � P•518-761-8256 v,w4 Invoice#: 6(Pd-5 ci-ec• Iok�,;I6r Project Location: �Y t-4 Rout• . l � Tax Map #: r —' as Subdivision Name:. • TOWN BD.RESOLUTION 86-2013.$850 recreation fee for new dwelling units: s" Arnityrcluplexes/twoziamity multiplefamily, apartments,condominiums townhouses,andbr manufactured & t u ar bt)tki t rtt bl homes. This is in addition to the permit fee(s). Lai; CONTACT INFORMATION: Ji 26' 'a( • Applicant: TOWN OF OUEENSBUR a® Name(s): \*'1 v e °r st{ice - o v CO4 it rUNIT y DEVRmOP ENT Mailing Address, C/SIZ: 51 C 2C L - CZ_o a 4 f(L s c f-� 1(s N y l� '"3 I'CeII Ph.: (6—I ) 020.9- g q `f ( T COLand Line: (SY ) %9e-0 33? Email: C tr1c �a C 4-;,1\ ?esyns v-LLE i Or, co . Corn • Primary Owner(s): Name(s): ,9114- ` t `, ,01 v n a- 5 5 Mailing Address, C/S2: I0 5 ctf ( oaf 1 q Cell Ph.: ( ) Land Line:(.5I ) T - w9z-1( Email: aix}\ e ,tom c o . r-1 • Contractors ; Name(s): Fpl ' c . Mailing Address, C/S/Z: Cell Ph.: -__( ) Land Line: ( ) Email: • • Architect(s)/Engineer(s): , Name(s): k-evsn futier) s drrr-1-1-; Fd ) .Po ; r,--/-- jI-tensed et gth.ee Mailing Address, C/SIZ: • Cell Ph.: ( ) Land Line: ( ) Email: Contact Person for Building &Code Compliance: 10rn C� r'e c k S t`L • Cell Ph.: _(.5 I ' )a 9,c(- )O'1 Land Line: _(5I f ) `7g f--O.3 3 ? Email:-+-bmSr ?C0 Lk_0-A. or\Q:0 cQ vvl Inn Building R Code Enforcement Princinle Structure Revised March 201R • PROJECT INFORMATION: • TYPE: Commercial .NA. Residential WORK CLASS: • Single-Family Two-Family Multi-Family(#of ) Townhouse Business Office _Retail Hotel/Motel IndustriialANarehouse I Garage(#ofcars c-) Other(describe ) CA 4i-i6d-aer STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: / �??C7 • 1 floor: J �� — 1�floor, • � - 2nd floor: '7 4 tir e_ .2nd floor: 3`a floor: Total square feet: / /5 a Basement(habitable space): ()b i7- (ti U " 524 Total square feet: 1, (7C) • ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ DO 0 2. Proposed use of the building: ^Snq/e. 3. If Commercial or Industrial,indicate the name of the business: 4. Source of Heat(circle one): Gas Oil Propane Solar Other: (Fireplaces need a separate Fuel Burning is ces&Chimney Application,one per appliance) 5. Are there any structures not shown on the plot plan? YES Explain: . 6. Are there any easements on the property? YES NO 7. SITE INFORMATION; a.What is the dimensions or acreage a he parcel? £OQ x 1,01 0 b.Is this a corner lot? YES c.Will the grade be changed as a resu'—of the construction? YES NN d.What is the water source? PUBLIC PRIVATE p 441, e. Is the parcel on SEWER or a PRIVATE SEPTIC system? 0(► ‘rai- • Ton Ruikiina Re Code Fnfnrcement Prinrinla<trrrrtnra R.ukorl March 7f1R t DECLARATION: I. I acknowledge that no construction shall commence priorto issuance of a valid building perm and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a t rue and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. • 5. I understand that Ikue are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities priorto issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: OIhcL1 $ 14)kree SIGNATURE: DATE: 7,2�J0o TOO Building&Code Enforcement Prinrinle Strut-him Pm/iced Marrh 7n1R - SEPTIC DISPOSAL PERMIT APPLICATI ON Office Use oral 742 Bay Road,Queensbury,NY 12804 P.518-76 1-8256 _ / Permt#f R-�-`t42\- ZQ tb � Tax Map ID#: 6 !/ �/ — 3 Permit Fee:$ invoice# Pro'ect Location: /05 6- /'e Re,`e-7Ae i Septic Variance? Y:-; N c) Primary Owner(s) w'i et,f `M e If-,et_ Ste Mailing Address l 0.-.T 5-tai e , o tJ e /q 1 Phone& Email 6 %gal - 1 Fq y G1 i,vj/A+• __ i f 5 key e Vrc-)vo� corm Installer/Builder -Ali-kW Co¢'1��r 0..-(-i b,� I `� c, Mailing Address f of71/4 50/i I'a//5 AIY /�._ ,57 / Phone& Email 55-i g '7 7?.-0 0/ dy a- eh;ll-i-opcong-frtztotico . cob-) Engineer 17 tf ell Ten S //JG,n e i i ") Mailing Address v / q Nd V//a i?d o d , qii-ee y?5b cc r fi JJ ?c`/ Phone& Email �5/ -) 17 5_030 7 y Contact Person for Building&Code ComplianCt 161Y\ A 1)ree-I4P I an9.-(57 )601C1- '70LI . t'• RESIDENCE NFORMATION: Year Built #of bedrooms X gallons,per bedroom = totaldaily flow Garbage Grinder Yes 0 'B80 or older Installed? {circle one) 1981-1991 Spa or Hot Tub Yes No Installed? (circle one) 1912-Press nt 3 / / CG _______ 3 o PARCEL NFORMATION: Topography Vlat Rolling Steep Slope %Slope Soil Nature and _Loam Clay _Other Groundwater At what depth? n 0 n•e- .-, i - 0 t/g / Bedrock/Impervious material At what depth? Domestic Water Supply „Municipal .Well{if well,wate r supply from any septic systen is Jb0 ft.) Percolation Test Rate: f, 5- per minute per inch{test to be completed by licensed engneer/arcltect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size I DO0 gallons{min.size 00O gallonsadd 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length /50 ft.;Each Trench 5`6 ft. x 3 Seepage Pit with#3 stone How many: •Size: Alternative System Bed or other type: I I HoldingTarikSystem Total required capacity? lank size •# of tanks NOTES:1.Alarm system&associated electrica lwork must be inspected by a Town approve t real inspai{iota V E agency;2.We will no longer allow systems to be covered until such time as an as-built plan• e' ed and approver. The installed system must match the septic layout on file-no exceptions. JUL 03 2 EYA Declaration:Any permit or approval granted which is based upon or is granted in reliance u on)? f-naateriai representation or failure to make a material fact or circumstance known by or on behalf of a `17ha�'llke 'tirtl-,11Y ��gi���f.,,'sari'�'i"rN- -� :�, ENT have read the regulations and agree to abide by these and all requirements ofthe Town of Q eerrsb�rry=Safaite Disposal Ordinance. C a . �6reck PRINT NAME: ►h s DATE: SIGNATURE: �-'I a DATE: 7� / r • Town of Oueensbury Building&Code Enforcement Revrsed February 20 f7 Town of Queensbury Thomas R.Van Ness -Highway Department Highway Superintendent 742 Bay Road,Queensbury, NY 12804 Home:518-745-0929 Phone:518-761-8211 Fax:518-745-4466 David Duet, Deputy Highway Superintendent Home:518-745-0938 DRIVEWAY PERMIT \YI Date: 7` - JUL Applicant Name: ` J l b [1 ®d1S f Y-(,{, ( 6 Telephone No.: 0- F� 7. 033 TOWN OF QUEENSBURY I _" LO,P Iir7EN`3' Address to be Inspected: /055 `11 e,7 ' dCdG4 7 e Return Address: Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: (4 Preliminary approval NEED _ ( ) Slight Swale V V ( ) Deep Swale • (4 Level with the road V ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) V ( ) 12" - ( ) 15" ( ) 18" 04 24" ( )36" Preliminary inspection completed by: Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R.Van Ness, Highway Superintendent David Duel', Deputy Highway Superintendent Town of Queensbury Building&Code Enforcement Principal Structure Application Revised February 2017 INSPECTION WORKSHEET (001776-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0426-2018 Case Module:Permit Inspection Date:Thu Apr 4, 2019 Inspection Status:Failed Inspector:Charles Dyer Inspection Type:Residential Final Inspection Job Address:Parcel Number:1049 State Rte 149 Fort Ann, NY 12827 266.4-1-3 Contact Type Company Name Name Primary Owner Ilsley, Thelma Contractor Hilltop Construction Architect Havens, Kevin Applicant Hilltop Construction Primary Owner Ilsley, Dwight Engineer LaPoint, Ed Checklist Item Passed Comments General Comments NO 1. Provide house numbers as indicated 2. Fire stop penetrations as discussed at basement area 3. Blower door test results 4. Engineer asbuilt report for septic system 5. Truss ID @ meter box- type V with FR (floor/roof) 6. Sticker at utility area for energy code 7. Pellet stove inspection from fire marshal Above items needed for issuance of CO- 4/4/18 4 inch Building Number Address visible from road NO Chimney Height / B Vent / Direct Vent Location YES Apr 04, 2019 Page (1) INSPECTION WORKSHEET (001776-2019) Checklist Item Passed Comments Chimney Rain Cap Installed YES Fresh Air Intake YES Fresh air supply 3' from grade YES For HRV 3" Plumbing Vent through roof minimum 18 inch YES Outside Spigots have Air Gap YES Roof Complete / Exterior Finish Complete YES Platform at all exterior doors YES Handrail 4 or more risers YES Guards at stairs,decks,patios 30" + above grade YES Guard at stairwell at 34" or more YES Window guards req:<2' above floor/6' above grade - quick release installed YES Guard at deck, porches 36" or more NO Porch under 30" from grade Handrail Termination at Newell Post or Wall YES Interior/Exterior Railings 34 to 38 YES 4+ Deck Joist Ledger Connections-24" From Ends YES Apr 04, 2019 Page (2) INSPECTION WORKSHEET (001776-2019) Checklist Item Passed Comments Deck Ledger-Bolted per Code YES Grade away from foundation: 6" down, 10' out NO 6" clearance to sill plate YES Interior privacy/trim/doors/main entrance 36 YES Bathroom / Kitchen Watertight YES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet YES Smoke Detectors: Carbon Monoxide YES Every level, Every bedroom YES Outside every bedroom area YES Inter Connected YES Battery backup: _____YES Attic Access 22 x 30 minimum YES Attic Access Insulation = Attic R- Value YES Attic Access Gasketed NO Provide weather stripping at access Bathroom Fans, if no window YES Apr 04, 2019 Page (3) INSPECTION WORKSHEET (001776-2019) Checklist Item Passed Comments Plumbing fixtures YES Backflow Preventors where required YES Foundation insulation to floor YES Energy Sticker on Elec. Panel:R-Val. & Heating Sys NO All Hot Water Systems: R-3 YES Duct work sealed properly NO Hydronic heat Insulated ducts for HRV Intake Openings YES Blower Door Test Certification NO Provide blower door HRV or ERV Installed per Bedroom Requirements YES Emergency egress below grade YES Propane Tank: Proper Setback from Prop Line/Struct YES Furnace Hot Water Heater operating YES Low water shut-off boiler YES Relief Valve ,Heat Trap/Water Temp 110 deg or less YES Apr 04, 2019 Page (4) INSPECTION WORKSHEET (001776-2019) Checklist Item Passed Comments 1/2" Gypsum or House Wall and Gable YES 5/8" Type X with Living Space Above YES Storage only 20 Minute Fire Door/Self-Closing Hardware YES Seals on Garage Doors, esp. Wood YES Basement stairs closed rise greater than 4 inches YES Basement Egress: 5s.f. window w/sill or Bilco door YES Jack posts in basement lagged at top and bottom YES Garage Floor Pitched YES Gas Log In Sealed or Glass Enclosure NO Plans calling for pellet stove, no record of fire marshal inspection Fin Elect; Energy Saving Light Bulbs 50 Percent YES Final Survey Plot Plan NO Provide final survey Arc Fault Breaker Habitable Spaces YES As Built Septic System NO Provide engineer asbuilt report Site Plan / Variance required NO Flood Plain Certification, if required NO Apr 04, 2019 Page (5) INSPECTION WORKSHEET (001776-2019) Checklist Item Passed Comments Fuel Tanks above flood plain elevation NO Buried Fuel Tanks anchored in flood zone NO Truss ID Signage Installed at Electrical Meter NO Provide truss ID sticker @ meter OK to Issue Temporary C/O NO OK to Issue C/O NO Apr 04, 2019 Page (6) Dyer, Charles (Inspector) Load Short Form Job: Ilsley 4, Date: Jul 16,2018 - Entire House By: Tout ATaci'Es Thermal Associates • • 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Project Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Design Information Htg Clg Infiltration Outside db (°F) -10 85 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 80 10 Fireplaces 1 (Average) Daily range - M Inside humidity (%) ' 50 50 Moisture difference(gr/lb) 53 27 HEATING EQUIPMENT COOLING EQUIPMENT Make Navien Make n/a Trade Combi Trade n/a Model NCB210 Cond n/a AHRI ref 8580771 Coil n/a AHRI ref n/a . Efficiency 95 AFUE Efficiency n/a Heating input 100000 Btuh Sensible cooling 0 Btuh Heating output 95000 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 85 ft Actual air flow 333 cfm High output baseboard 700 Btuh/ft Air flow factor 0.046 cfm/Btuh Total high baseboard 60 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.76 ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF (ft2) (Btuh) (Btuh) Low High (cfm) Room1 1906 17865 477 36 26 22 Room2 1906 24441 6758 49 35 311 Entire House d 3812 42306 7235 85 60 333 Other equip loads 3374 2128 Equip. @ 0.90 RSM 8427 Latent cooling 2983 TOTALS 1 3812 I 45680 I 11410 I 85 60 I 333 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r,f NEtSaft 2018-Jul-1615:57:22 Right-Suite®Universal 2017 17.0.21 RSU24121 Page 1 ACCk ..)\jobcost12018\Hilltop.11sayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S { Loads for Multiple Orientations Job: Ilsley -v Date: Jul 16,2018 Entire House By: UM ASSOCICES Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Project Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 80 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 52.8 26.5 Dry bulb(°F) -10 85 Infiltration: Daily range (°F) - 22 ( M ) Wet bulb(°F) - 71 Wind speed (mph) 15.0 7.5 Front Door . North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh). 7628 9024 9790 9360 8427 10251 10545 8975 Latent Load (Btuh) 2983 2983 2983 2983 2983 2983 2983 2983 Total Load (Btuh) 10611 12007 12773 12343 11410 13234 13528 11958 Heating AVF(cfm) 0 0 0. 0 0 0 0 0 Cooling AVF(cfm) 292 363 403 381 333 426 441 361 • Building Orientation Cooling Load 1-els 1nu 0 N NE E SE S SN W WV Dreiat Fiat Dxrfaoss Current Orientation: Front Door faces South Highest Cooling Load: Front Door faces West . • Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Jul-16 15:57:22 r Wrightsoft" Right-Suite®Universal 2017 17.0.21 RSU24121 Page 1 Ara.. ...)1jobcost12018\HilltopilsayNCE\ILSLEY.heatload Calc=MJ8 Front Door faces: S 1' Analysis BuildingJob: !Islay 41:41 Date: Jul 16,2018 Entire House By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Pro'ect Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Desi• n Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 80 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 52.8 26.5 Dry bulb(°F) -10 85 Infiltration: Daily range (°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Heatin• Component Btu h/ft2 Btuh %of load • Walls 5.9 20343 44.5 1a101 Glazing 32.8 5117 11.2 Irfiltrafim Doors 23.2 1949 4.3 • • Ceilings 1.6 3050 6.7 vtil Floors 2.0 3812 8.3 Infiltration 3.3 8036 17.6 Ducts 0 0 Roos Piping 0 0 Humidification 0 0 IL , Gangs • Ventilation 3374 7.4 •Ga ors arg Adjustments 0 Total 45680 , 100.0 Coolin• Component Btu h/ft2 Btuh % of load Walls 0.4 1348 14.4 WA Dante Glazing 21.1 3290 35.1 Doors 6.0 502 5.4 Ceilings 0.9 1681 18.0Iatim Floors 0 0 0 Infiltration 0.2 414 4.4 Iriiltrdial Ducts 0 0 Ventilation 422 4.5 Internal gains 0 0 gaarg Blower 1707 18.2 I Cams . Adjustments 0 Total 9363 100.0 Dori Latent Cooling Load=2983 Btuh Overall U-value=0.055 Btuh/ft2-°F • WARNING:window to floor area ratio=4.1%-less than 5%. Bold/italic values have been manually overridden • 2018-Jul-16 15:57:22 . 111drightso " Rig ht-Suite®Universal 2017 17.0.21 RSU24121 Page 1 . C1 ....)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S . Component Constructions Job: Ilsley Date: Jul 16,2018 Entire House By: '' " Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Pro'ect Information For: Ilsley • 1055 State Route 149, Queensbury,NY 12804 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 70 75 Elevation: 335 ft Design TD (°F) 80 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 52.8 26.5 Dry bulb(°F) -10 85 • Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) • Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fr Btuh/ft'°F fF°F/Btuh Btuh/fr Btuh Btuh/fr Btuh Walls • 12F-0sw:Frm wall,wd ext, 1/2"wood shth,r-21 cav ins, 1/2"gypsum n 462 0.065 21.0 5.20 2402 0.61 282- board int fnsh,2"x6"wood frm,16"o.c.stud e 357 0.065 • 21.0 5.20 1856 0.61 218 s 423 0.065 21.0 5.20 2200 0.61 258 • w 354 0.065 21.0 5.20 1841 0.61 216 all 1596 0.065 21.0 5.20 8299 0.61 975 15B-8s3c-6:Bg wall,heavy dry or light damp soil,concrete wall,r-8 n 540 - 0.073 8.0 6.56 3542 0.20 110 ins,8"thk,1/2"gypsum board int fnsh e 378 0.073 8.0 6.56 2480 0.20 77 s 540 0.073 8.0 ' 6.56 3542 0.20 110 w 378 0.073 8.0 6.56 2480 0.20 77 all 1836 0.073 8.0 6.56 12044 0.20 373 Partitions (none) Windows 4A5-2of:2 glazing,clr low-e outr,argon gas,insulated fiberglass frm n 36 0.410 0 32.8 1181 9.99 360 mat,clr innr,1/2"gap, 1/4"thk;6.67 ft head ht s 96 0.410 0 32.8 3149 18.0 1727 w 24 0.410 0 32.8 787 33.1 795 all 156 0.410 0 32.8 5117 18.5 2881 Doors 11 P0:Door,mtl pur core type n 42 0.290 10.5 23.2 974 5.97 251 e 21 0.290 10.5 23.2 487 5.97 125 s 21 0.290 10.5 23.2 487 5.97 125 all 84 0.290 10.5 23.2 1949 '5.97 502 Ceilings 16B-50ad:Attic ceiling,asphalt shingles roof mat,r-50 ceil ins,5/8" 1906 0.020 50.0 1.60 3050 0.88 1681 gypsum board int fnsh Floors 21A-24t:Bg floor,heavy dry or light damp soil,6'depth 1906 0.025 0 2.00 3812 0 0 Wl'1 hSt2018-Jul-1615:57:22 Rig Universal2017 17.0.21 RSU24121 Page 1 ACak ..)\jobcost\2018\Hilltop.11sayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S n. ` Project Summary Job: Ilsley 1 Date: Jul 16,2018 tow Entire House By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Pro-ect Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Notes: • Desi•n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -10 °F Outside db 85 °F Inside db 70 °F Inside db 75 °F Design TD 80 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 42306 Btuh Structure 7235 Btuh • Ducts 0 Btuh Ducts 0 Btuh Central vent(SER=70% 129 cfm) 3374 Btuh Central vent(SER=70% 129 cfm) 422 Btuh Heat recovery Heat recovery • Humidification 0 Btuh . Blower 1707 Btuh • Piping 0 Btuh Equipment load 45680 Btuh • Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 8427 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces • 1 (Average) Structure 679 Btuh Ducts 0 Btuh Central vent(129 cfm) 2304 Btuh Heating Cooling Heat recovery Area(ft2) 3812 3812 Equipment latent load 2983 Btuh Volume (ft3) 22872 22872 Air changes/hour 0.24 0.10 Equipment total load . 11410 Btuh Equiv.AVF (cfm) 92 38 Req.total capacity at 0.70 SHR . 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make Navien Make n/a Trade Combi Trade n/a Model NCB210 Cond n/a AHRI ref 8580771 Coil n/a AHRI ref n/a Efficiency 95 AFUE Efficiency n/a Heating input 100000 Btuh Sensible cooling 0 Btuh Heating output 95000 Btuh Latent cooling 0 Btuh Low output baseboard 700 Btuh/ft Total cooling 0.046 cfm/Btuh Total low baseboard 60 ft Actual air flow 0 in H2O High output baseboard Air flow factor 0.76 Total high baseboard Static pressure Space thermostat Load sensible heat ratio Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Jul-16 15:57:22 wrigIHICSO '"' Rig ht-Suite®Universal 2017 17.0.21 RSU24121 Page 1 t '% ...)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S S AED Assessment Job: lisley ei:+ Date: Jul 16,2018 Entire House By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Project Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Design Conditions Location: Indoor: Heating Cooling . • Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD(°F) 80 10 Latitude: . 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 52.8 26.5 Dry bulb(°F) -10 85 Infiltration: Daily range (°F) - 22 ( M ) . Wet bulb(°F) - 71 - Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity . Fbu1y Gazing Load . 5,500- 5,000- 4,500- 4,000 . ------...--- ss.s........ ..,\ — 3,500- 3,000- 2,500 • — 2,000- 1,500— 1,00 e 500— 0 I I I I I I I 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour ofDay • /Huy /A ,AED hr,y Maximum hourly glazing load exceeds average by 41.1%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 408 Btuh (PFG - 1.3*AFG) Bold/italic values have been manually overridden Wi-i. htsoft- 2018-Jul-16 15:57:22 Right-Suite®Universal 2017 17.0.21 RSU24121 Page 1 ACM...)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S - Right-JO Worksheet Job: llsley, Tim Date: Jul 16,2018 Entire House By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com 1 Room name Entire House Room1 2 Exposed wall 408.0 ft 204.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 1906.0 ft 5 Room area 3812.0 ft' 1906.0 ft' I I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) I Heat I Cool Gross N/P/S Heat I Cool I Gross N/P/S Heat Cool I 6 I 12F-05w 0.065 n 5.20 0.61 540 462 2402 282 0 0 0 0 4A5-201 0.410 n 32.80 9.99 36 0 1181 360 0 0 0 0 . D 11P0 0.290 n 23.20 5.97 42 42 974 251 0 0 0 0 W 15B-8s3c-6 - 0.100 n 6.56 0.20 540 540 3542 110 540 540 3542 110 11 I 12F-Osw 0.065 e 5.20 0.61 378 357 1856 218 0 0 0 0 D 11 PO 0.290 e 23.20 5.97 21 21 487 125 0 0 0 0 W 15B-8s3c-6 0.100 e 6.56 0.20 378 378 2480 77 378 378 2480 77 W 12F-0sw 0.065 a 5.20 0.61 540 423 2200 258 0 0 0 0 C 4A5-2of 0.410 s 32.80 17.98 96 0 3149 1727 0 0 0 0 D 11 PO 0.290 s 23.20 5.97 21 21 487 125 0 0 0 _ 0 W 15B-8s3c-6 0.100 s 6.56 0.20 540 540 3542 110 540 540 3542 110 VII 12F-05w 0.065 w 5.20 0.61 378 354 1841 216 0 0 0 0 G 4A5-2of 0.410 w 32.80 _ 33.12 24 0 787 795 0 0 0 0 W 15B-8s3c-6 - 0.100 w 6.56 0.20 378 378 2480 77 378 378 2480 77 C 16B-50ad 0.020 - 1.60 0.88 1906 1906 3050 1681 0 0 0 0 F 21A-24t 0.025 - 2.00 0.00 1906 1906 3812 0 1906 1906 3812 0 • 6 c)AED excursion 1 40 34271 682$ I 15856 373 Envelope loss/gain 12 a) Infiltration 8036 414 2009 104 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 42306 7235 17865 477 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 42306 7235 17865 477 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 1 1 Total room load LowIH gh Baseboard/Cool Air I I 851 42306 60I 7235 333I ( 361 17826651 422I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri hts 7'f#" 2018-Jul-16 15:57:22 Right-Suite®U niversal 2017 17.0.21 RSU24121 Page 1 ..)\jobcost\2018\Hilltop.11sayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S • a Right-J® Worksheet Job: Haley Entire House Date: Jul 16,2018 By: Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com 1 Room name Room2 2 Exposed wall 204.0 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 1906.0 ft 5 Room area 1906.0 ft' I Ty Construction U-value Or I HTM I Area (ft') I Load I Area I Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat I Cool I Gross N/P/S I Heat 1 Cool Gross I N/P/S 1 Heat 1 Cool 6 y/ 12F-05w 0.065 n 5.20 0.61 540 462 2402 282 I� G 4A5-20f 0.410 n 32.80 9.99 36 0 1181 360 . D 11 PO 0.290 n 23.20 5.97 42 42 974 251 W 15B-8s3c-6 0.100 n 6.56 0.20 0 0 0 0 11 12F-Osw 0.065 e 5.20 0.61 378 357 1856 218 D 11 PO - 0.290 e 23.20 5.97 21 21 487 125 • W 15B-853c-6 0.100 e 6.56 0.20 0 0 0 0 WD 12F-0sw 0.065 s 5.20 0.61 540 423 2200 258 4A5-201 0.410 s 32.80 17.98 96 0 3149 1727 11P0 0.290 s 23.20 5.97 21 21 487 125 W 15B-8s3c-6 0.100 s 6.56 0.20 0 0 0 0 VJ 12F-0sw 0.065 w 5.20 0.61 378 354 1841 216 -G 4A5-20f 0.410 w 32.80 33.12 24 0 787 795 W _ 15B-8s3o-6 0.100 w 6.56 _ 0.20 0 0 0 0 _ C 16B-50ad 0.020 - 1.60 0.88 1906 1906 3050 1681 F 21A-24t 0.025 - 2.00 0.00 0 0 0 0 • 6 c)AED excursion I 18414I 6448 1 Envelope loss/gain 12 a) Infiltration 6027 311 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 24441 6758 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 24441 6758 15 Duct loads -0% 0% 0 0 1 1 Total room load LowiHigh Baseboard/Cool Air I I 491 244351 6318I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr'�gh# � � 2018-Jul-16 15:57:22 Right-Suite®U niversal 2017 17.0.21 RSU24121 Page 2 ...)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S Manual S Compliance Report Job: !Islay Date: Jul 16,2018 $ Entire House By: TAM Thermal Associates • 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Project Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 9363 Btuh Entering coil DB: 0°F Outdoor design WB: 70.8°F Latent gain: 2983 Btuh Entering coil WB: 0°F Indoor design DB: 75.0°F Total gain: 0 Btuh Indoor RH: 50% Estimated airflow: 333 cfm • Manufacturer's Performance Data at Actual Design Conditions Equipment type: ' Manufacturer: Model: • Actual airflow: 333 cfm Sensible capacity: 0 Btuh 0%of load Latent capacity: 0 Btuh 0% of load Total capacity: • 0 Btuh 0%of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -10°F Heat loss: 45680 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Prop boiler Manufacturer: Navien Model: NCB210 Actual airflow: 0 cfm Output capacity: 95000 Btuh 208%of load Meets are all requirements of ACCA Manual S. -{_�1-- 2018-Jul-16 15:57:23 wrtghtsoftT Right-Suite®Universal 2017 17.0.21 RSU24121 Page 1 ..)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Cale=MJ8 Front Door faces: S DHW Report Job: Ilsley `? Date: Jul 16,2018 Entire House By: UMW ASSVATP Thermal Associates 21 Thomson Ave,Glens Falls,NY 12801 Phone:518.798.5500 Fax:518.798.5620 Email:adam@thermalassociates.com Web:www.thermalassociates.com Project Information For: Ilsley 1055 State Route 149, Queensbury, NY 12804 Design Criteria Occupants Not occupied during the day Age Number Dishwasher 0-5 0 Clothes washer 6-13 1 Additional use (gpd) 0 14-59 2 Setpoint(°F) 120 60+ 0 Daily use (gpd) 44 Propane instantaneous (0 gal, 0.92 EF) • Manufacturer Takagi Industrial Co. USA I Trade name Energy factor 0.92 Model T-H1 Input (MBtuh) 0.2 AHRI ref. number . 740841 1st hour (gpm) 5 . • Recovery eff. (%) 93 • • • • • • • • • 2018-Jul-16 15:57:23 wrightsoft' Right-Suite@ Universal 2017 17.0.21 RSU24121 Page 1 ACCk...)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Cale=MJ8 Front Door faces: S Residential Plans Examiner Review FormifC Form C RPER 1 for HVAC System Design (Loads, Equipment, Ducts) 15Mar09 Arr.c.xikrivw-tratiwroxs Header Information Contractor: Thermal Associates REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ❑ No El Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes ❑ No ❑ OEM performance data(heating,cooling,blower): Yes El No ❑ Building plan#: Manual D Friction Rate Worksheet: Yes ❑ No ❑ Duct distribution sketch: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): 1055 State Route 149, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: _10 °F Orientation: Front Door faces South Indoor temperature: 70 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 45680 Btuh Number of bedrooms: 0 Conditioned floor area: 3812 ftz Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Rase; Grains difference: 27 gr/Ib @50% RH Eave overhang depth: 0 ft _ Sensible heat gain: 10404 Btuh Internal shade: none EEVe. • Latent heat gain: 3314 Btuh Blinds,drapes,etc. Deo', window Total heat gain: 13718 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data . Blower Data Equipment tpe: Prop boiler Equipmentpe: Heating cfm: 0 ornate,Hea pump,Boiler,etc. it conditio er,Heat pump,etc. Cooling cfm: 333 Model: Navien Model: Static pressure: 0 in H2O NC6210 Fan's rated external static pressure for design airflow Heating output capacity: 0 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacity at winter design outdoor conditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh . HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 333 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Round flex vinyl Friction Rate=ASP>(T EL x 100) I declare the load calculation,equipment,equipment selection and duct design were rigorously performed based on the building plan , listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: • Reserved for County,Town Municipality or Authority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist 1_ rightso r Right-Suite®Universal 2017 17.0.21 RSU24121 x , .. HVAC Design Report ENERGY STAR Certified Homes, Version 3 / 3.1 (Rev. 08) HVAC Designer Responsibilities: •Complete one HVAC Design Report for each system design for a house plan,created for either the specific plan configuration (i.e., elevation, option,orientation,&county)of the home to be certified or for a plan that is intended to be built with potentially different configurations(i.e., different elevations,options,and/or orientations).Visit www.energystar.gov/newhomeshvacdesign and see Footnote 2 for more information. •Obtain efficiency features (e.g.,window performance,insulation levels,and infiltration rate)from the builder or Home Energy Rater. •Provide the completed HVAC Design Report to the builder or credentialed HVAC contractor and to the Home Energy Rater. 1.Design Overview 1.1 Designer name:Adam DeVit Designer company:Thermal Associates Date:Jul 16,2018 1.2 Select which party you are providing these design services to: IN Builder or 0 Credentialed HVAC contractor 1.3 Name of company you are providing these design services to(if different than Item 1.1): 1.4 Area that system serves: IN Whole-house El Upper-level El Lower-level 0 Other 1.5 Is cooling system for a temporary occupant load? 0 Yes •No 1.6 House plan: Check box to indicate whether the system design is site-specific or part of a group: M Site-specific design.Option(s)&elevation(s)modeled: 0 Group design.Group#:0 out of 0 total groups for this house plan. Configuration modeled: Designer 2.Whole-House Mechanical Ventilation Design Verified Airflow: 2.1 Ventilation airflow design rate&run-time meet the requirements of ASHRAE 62.2-2010 or 2013 MI 2.2 Ventilation airflow rate required by 62.2 for a continuous system 129 CFM - 2.3 Design for this system:Vent.airflow rate: 129 CFM Run-time per cycle: 0 minutes Cycle time: 0 minutes - System Type&Controls: 2.4 Specified system type: 0 Supply D Exhaust •Balanced - 2.5 Specified control location: (e.g.,Master bath,utility room) - 2.6 Specified controls allow the system to operate automatically,without occupant intervention ED 2.7 Specified controls include a readily-accessible ventilation override and a label has also been specified if its function is not D obvious (e.g.,a label is required for a standalone wall sw itch, but not for a sw itch that's on the ventilation equipment) 2.8 No outdoor air intakes designed to connect to the return side of the HVAC system,unless specified controls operate. 0 intermittently and automatically based on a timer and restrict intake when not in use(e.g.,motorized damper) Sound: 2.9 The fan of the specified system is rated<-3 sones if intermittent and<_1 sone if continuous,or exempted o Efficiency: 2.10 If system utilizes the HVAC fan,then the specified fan type in Item 4.7 is ECM/ICM,or the specified controls will reduce D the standalone ventilation run-time by accounting for hours when the HVAC system is heating or cooling 2.11 If bathroom fans are specified as part of the system,then they are ENERGY STAR certified 0 Air Inlet Location: (Complete this section if system has a specified air inlet location;otherw ise check"N/A") 0 N/A 2.12 Inlet pulls ventilation air directly from outdoors and not from attic,crawlspace,garage,or adjacent dwelling unit I= 2.13 Inlet is>-2 ft. above grade or roof deck;>_10 ft. of stretched-string distance from known contamination sources (e.g., CI stack,vent,exhaust,vehicles)not exiting the roof,and z 3 ft.from know n sources exiting the roof 3.Room-by-Room Heating&Cooling Loads 3.1 Room-by-room loads calculated using: M Unabridged ACCA Manual J v8 0 2013 ASHRAE Fundamentals El Other per AHJ - 3.2 Indoor design temperatures used in loads are 70°F for heating and 75°F for cooling El 3.3 Outdoor design temperatures used in loads:(See Footnote 12 and energystar.gov/hvacdesigntemps) - County&State selected:Washington,NY Cooling season: 85°F Heating season: -10°F 3.4 Number of occupants used in loads: 0 - 3.5 Conditioned floor area used in loads: 3812 Sq.Ft. - 3.6 Window area used in loads: 156 Sq.Ft. - 3.7 Predominant window SHGC used in loads: 0.31 - 3.8 Infiltration rate used in loads: Summer: 0.10 Winter: 0.24 - 3.9 Mechanical ventilation rate used in loads: 129 CFM - Loads At Design Conditions(kBtuh) N NE E SE S SW W NW - 3.10 Sensible heat gain(By orientation) 7.6 9.0 9.8 9.4 8.4 10.3 10.5 9.0 - Cooling 3.11 Latent heat gain(Not by orientation) 3.0 - 3.12 Total heat gain(By orientation) I 10.6 I 12.0 I 12.8 I 12.3 I 11.4 I 13.2 I 13.5 I 12.0 I - 3.13 Maximum-minimum total heat gain(Item3.12)across orientations= 2.9 kBtuh I Variation is<_6 kBtuh I• Heating 3.14 Total heat loss(Not by orientation) 45.7 - • . Bold/italic values have been manually overridden • 2018-Jul-16 15:57:23 Right-Suite®U niv ersal 2017 17.0.21 RSU24121 Page 1 ...)\jobcost\20181Hilltop.IlsayNCB\ILSLEY.heatioad Calc=MJ8 Front Door faces: S t , . E HVAC Design Report j. ENERGY STAR Certified Homes, Version 3 / 3.1 (Rev. 08) ,taif Designer 4.Heatina&Cooling Equipment Selection Verified 4.1 Equipment selected per ACCA Manual S(see Footnote 19&20) o Air Conditioner/Heat Pump (Complete if air conditioner or heat Du mg will be installed:otherwise check"N/A') • N/A 4.2 Equipment type: o Cooling-only air conditioner or E Cooling&heating heat pump - 4.3 Condenser manufacturer&model: - 4.4 Evaporator/fan coil manufacturer&model: - 4.5 AHRI reference#: - 4.6 AHRI listed efficiency: / EER/SEER Air-source heat pump: HSPF Ground-source heat pump: COP - 4.7 Evaporator fan type: 0 PSC D ECM/ICM E Other: - 4.8 Compressor type: D Single-speed IP Two-speed IP Variable-speed - 4.9 Latent capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.10 Sensible capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.11 Total capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.12 Air-source heat pump capacity: At 17°F: 0 kBtuh At 47°F: 0 kBtuh 0 N/A - 4.13 Cooling sizing%=Total capacity(Item 4.11)divided by maximum total heat gain(Item 3.12): 0% - 4.14 Complete this Item if Condition B Climate w ill be used to select sizing limit in Item 4.15.Otherw ise,check"N/A": o N/A - 4.14.1 Load sensible heat ratio=Max.sensible heat gain(Item 3.10)/Max.total heat gain(Item 3.12) = 0% - 4.14.2 HDD/CDD ratio(Visit energystar.gov/hvacdesigntemps to determine this value for the design location) 3.3 - 4.15 Check box of applicable cooling sizing limit from chart below: - Equipment Type(Per Item 4.2)& Compressor Type(Per Item 4.8) Climate Condition(Per Item 4.14) Single-Speed I Two-Speed I Variable-Speed For Cooling-Only Equipment or Recommended:90-115% Recommended:90-120% Recommended:90-130% For Cooling Mode of Heat Pump in IDAllowed:90-130% D D Allowed:90-140% Allowed:90-160% Condition A Climate For Cooling Mode of Heat Pump in O 90%.-100%,plus 15 kBtuh El 90%-100%,plus 15 kBtuh 0 90%-.100%,plus 15 kBtuh Condition B Climate 4.16 Cooling sizing%(4.13)is within cooling sizing limit(4.15) D Furnace (Complete if furnace will be installed: otherwise check"N/A') - N/A 4.17 Furnace manufacturer&model: - 4.18 Listed efficiency: AFUE . - 4.19 Total capacity: kBtuh - 4.20 Heating sizing%=Total capacity(Item 4.19)divided by total heat loss(Item 3.14): 0% - 4.21 Check box of applicable heating sizing limit from chart below: - When Used for Heating Only When Paired With Cooling 0 100-140% El Recommended:100-140%Allowed: 100-200% 4.22 Heating sizing%(4.20)is within heating sizing limit(4.21) D 5.Duct Design (Complete if heatina or cooling ea uiom ent will be installed with ducts:otherwise check"N/A") • N/A 5.1 Duct system designed for the equipment selected in Section 4,per ACCA Manual D I] 5.2 Design HVAC fan airflow: Cooling mode CFM Heating mode CFM - 5.3 Design HVAC fan speed setting(e.g.,low,medium,high): Cooling mode Heating mode - 5.4 Design total external static pressure(corresponding to the mode with the higher airflow in Item 5.2): IWC - 5.5 Room-by-room design airflows documented below(which must sum to the mode with the higher airflow in Item 5.2) - Room Name Design Airflow(CFM) Room Name Design Airflow(CFM) 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 • 22 11 23 12 Total for all rooms 0 �- . 2018-Jul-16 15:57:23 Right-Suite®Universal 2017 17.0.21 RSU24121 Page 2 ...)\jobcost\2018\Hilltop.IlsayNCB\ILSLEY.heatload Calc=MJ8 Front Door faces: S a • REScheck.Software Version 4.6.4 Compliance Certificate 3p'^?_ � � -� ck ' 14410.11: F. *�: ',>t .n.., S,: ° €ward I ?nr �4 - Project llsley TOW' OF Qr:. ':a 1,.:=" URY Energy Code: 2015 IECC COMMUd` i d Y DEVELOPMENT Location: Glens Falls, New York -• Construction Type: Single-family Project Type: New Construction 266.4-1-3• Conditioned Floor Area: 1,906 ft2 RC-0426-2018 Glazing Area 7% llsley, Dwight & Thelma Climate Zone: 6 (7635 HDD) ' 1049 State Rte 149 Permit Date: Permit Number: I SFD 1880 s.f., Garage 1152 s.f. Construction Site: Owner/Agent: Designer/Contractor: 1055 stte rt 149 queensbury,NY 12804 Compliance:Passes using UA trade-off Compliance: 0.3%Better Than Code Maximum UA: 302 Your UA: 301 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value •Ceiling 1: Raised or Energy Truss 1,906 49.0 0.0 0.020 38 Wall 1:-Wood Frame, 16"o.c. 2,160 21.0 0.0 0.057 111 Window 1:Wood Frame:Double Pane with Low-E 117 0.260 30 Door 1:Glass 40 0.260 10 Door 2:Solid 40 0.280 11 Door 3:Solid 20 0.170 3 Basement Wall 1: Solid Concrete or Masonry 1,920 0.0 13.0 0.051 98 Wall height:8.0' Depth below grade:7.0' - . Insulation depth:8.0' • Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requiremen4;43"-ro heR\�cepection Checklist. KEIT-M 9,p. Name-Title Signatu //, 'i"' -`°-® 1 \\\ Date 1.f dJ r \90•r \if ix\=(4Jí, Project Title: llsley `� P. b , i I Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rc Page 1 of 9 REScheek Software Version 4.6.4 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software , - Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.1, !Construction drawings and pk :'_"% ,OComplies 103.2 .documentation demonstrate �.,::,;:� -` � �=:<-,._-=� `6i❑Does Not [PR1]1 energy code compliance for the rT `_ buildingenvelope.Thermal ❑Not Observable envelope represented on "` � ti'z 'j❑Not Applicable construction documents. =s' �`' 103.1, ;Construction drawings and ,. =t "='era :y �' 9 �� - ,❑Com lies d i 103.2, !documentation demonstrate _ 'J p '" � .`��-s�; �_`;.`,`'•, . ❑Does Not 403.7 !energy code compliance for _. i , ,,'=`'Y`.'''t"'-I❑Not Observable [PR3] ;lighting and mechanical systems. •, �� ` �; , ❑Not . .,° .1 l�7 Systems serving multiple � �° • •� a,�z�;_;"^;,. . ,,.,,: Applicable dwelling units must demonstrate h' pwiththelECC ' `.= ` .e`'. ,R:_= ,�.•.,.=;;:'r;_"_;-_>_,, ,Y`� compliance tii!! :: ..t = _ r. is# , Commercial Provisions. �,%� •� ''�- � ` I 302.1, (Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 ;sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: I Manual J or other methods Btu/hr Btu/hr ❑Not Observable !approved by the code official. ❑Not Applicable Additional Comments/Assumptions: • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 2 of 9 s Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.IQ 402.1.1 Conditioned basement wall R- R-_ ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R- R- ❑Does Not table for values. insulation is used,verification DNot Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations r in Climate Zone 3. - ,. 1 -:ism,..",.; ❑Complies 303.2 ;Conditioned basement wall I .--.:- �-.,' �� .. •• [F05]1 insulation installed per [a�,;;y_;_.-�" - _ , fib ❑Does Not manufacturer's instructions. �'''=, : T =: §Y- .,>•+� ...1 Not Observable : "� S F~ ;❑Not Applicable 402.2.9 Conditioned basement wall •ft ft ❑Complies See the Envelope Assemblies [F06i1 insulation depth of burial or — ❑Does Not table for values. V distance from top of wall. :Not Observable :Not Applicable 303.2.1 'A protective covering is installed i ` `'- ' ' '❑Com lies (F011]2 Ito protect exposed exterio j ' Y :-c,¢❑Does Not insulation and extends a 44E: _ ';❑Not Observable ;minimum of 6 in.below grade a " �.�, tih .-.;:'.,e -❑Not Applicable 403.9 Snow-and ice-melting system t;r r .� - ❑Complies [F012]2 controls installed. ssN 1' . , ❑Does Not i S s#. ' .'�.^Ct l7 ; • ° >��ay;?�": �., ❑Not Observable t_.•:_r. tea` '.++,f' .' .§, 1".9"�_" '- -4` ` �' ;. a w.�4,❑Not Applicable Additional Comments/Assumptions: . • • • 1 High Impact(Tier 1) -2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley. Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 3 of 9 Section # Framing/Rough-In Inspection Plans Verified Field Verified Complies? Comments/Assumptions & Req.lD Value Value 402.1.1, i Door U-factor. U- U-_ DComplies See the Envelope Assemblies [FR1]14 DDoes Not table for values. - ❑Not Observable ❑Not Applicable 402.1.1, JGlazing U-factor(area-weighted U- U- '❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ,[]Not Observable 402.5 ❑Not Applicable [FR2]1 1 F4•.. ,,, 303.1.3 U-factors of fenestration products�= :��,�, - ..,- £ .,-.:"---'� `• :DComplies [FR4] are determined in accordance ,k6 :`!- y ' - ,,t,,, ❑Does Not `� ! with the NFRC test procedure or ' ''� g` -•#'''" [❑Not Observable taken from the default table. i''.:,;';'1,„f , ,; . 6; -' �.- ,i ``` sy .N;;;,❑Not Applicable : . ';�--... p 402.4.1.1 ;Air barrier and thermal barrier ' :,,,- - ,-- . '-•`G. - 'DComplies [FR23] !installed per manufacturer's `'c-7, , -"' ::+❑Does Not J ;instructions. h " Fs#, ; - ' ,ii- `i❑Not Observable 0._1' w,❑Not Applicable 402.4.3 Fenestration that is not site built i-. = r;' '"c' .'y *., r. .�❑Complies [FR20]1 is listed and labeled as meeting ?ri AAMA/WDMA/CSA 101/I.S,2/A440 ti •, " � ° .74 „r1❑Does Not or has infiltration rates per NFRC ` , •• t A. ;°1❑Not Observable 400 that do not exceed code '' ,, `; ;❑Not Applicable limits. =1." ''' "` :4 .>< .,'. 402.4.5 IC-rated recessed lighting fixtures < - p`'`-; `❑Complies [FR16]2 sealed at housing/interior finish n ` p= -."]❑ and labeled to indicate<_2.0 cfm • Does Not • leakage at 75 Pa. r- ' Y`" ['Not Observable :Not Applicable 403.2.1 iSupply and return ducts in attics f•, P"r;' 1 ;,❑Complies [FR12]1 !insulated>= R-8 where duct is - S"'- E,•- :r.- -- ❑Does Not i>= 3 inches in diameter and>= ' '''' :. - R-6 where<3 inches.Supply and s`,, _ "- -'i❑Not Observable return ducts in other portions of . .-4 a , -J❑Not Applicable ;the building insulated>= R-6 for r 1n r ` ! :diameter>=3 inches and R-4.2 4 ,<a; 'T• '''' = ;for<3 inches in diameter. : =- ,�:.:.. �, -Nx '• ';per 403.3,3.5 iBuilding cavities are not used as t ,,a , .i❑Complies [FR15]3 [ducts or plenums, Ak;;_ •-_'. 'f;,-• - x -"❑Does Not I T' -. ;.�❑Not Observable ^, 4 '',ar,r ''❑Not Applicable 403.4 I HVAC piping conveying fluids R- ' R- DComplies [FR17]2 !above 105°F or chilled fluids ❑Does Not below 55°F are insulated to>_R- `3. ['Not Observable ❑Not Applicable 403.4.1 1 Protection of insulation on HVAC '' , .- "^"'s_, ^ - {t _ FR24]1 ,.,. '_ '1�. DComplies1 [ piping. -' xr,.. ;.�V � � ,:§s� � -ICI Not T. , .. f. %' . Not Observable - * - .. . r,c!_'' _ - P •❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- DComplies [FR18]2 >_R-3. ❑Does Not DNot Observable , ❑Not Applicable 403.6 ;Automatic or gravity dampers are -• DComplies; [FR19]2 !installed on all outdoor air • .t' ,.. . • •� _ • 1❑Does Not 'intakes and exhausts. L.t-,• x.,, a" i :.- I❑Not Observable • _.' ',;`}; IDNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 4 of 9 Additional Comments/Assumptions:- • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: llsley Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 5 of 9 • Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions & Req.1D 303.1 'All installed insulation is labeled ��';'..,'�,:4;:,� . .__ . .a❑Complies [IN13]2 or the installed R-values provided. _. ` },= ❑D Z oes Not ,, ', ..;; 'K ` '•.r. ❑Not Observable w`-, '❑Not Applicable 402.1.1, I Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 ;wall insulation on the wall [IN3]1 ;exterior,the exterior insulation ❑ Mass Mass❑ ❑Not Observable ID Steel Steel ❑Not Applicable applies(FR10). 303.2 Wall insulation is installed per ; r. `; I❑Complies [IN4]1 manufacturers instructions.` ; ; ❑Does Not JEINot Observable i❑Not Applicable Additional Comments/Assumptions: • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 6 of 9 • Section Plans Verified -Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Ceiling insulation R-value. R-_ R- ❑Complies See the Envelope Assemblies 402.2.1, I ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.E ❑ Steel ❑ Steel :Not Observable [FI1]1 , •❑Not Applicable i 303.1.1.1,;Ceiling insulation installed per '-•' "3�f yfr f p❑Complies 303.2 'manufacturer's instructions. [Fl2]1 �,yc' ❑Does Not Blown insulation marked every x� 3� T ;300 ft2. 4 s .' . --- 'SI-,,...;' Not Observable ' t,;•:4 r- _,..." „ s..-�. M - > _ ❑Not Applicable 402.2.3 ;Vented attics with air permeable "... �. ""'' ' ❑Com�,,, �"�,.� plies [FI22]2 'insulation include baffle adjacent , µ' 4n.. ', 4* =4^-_ .�` ❑Does Not lf:.. to soffit and eave vents that •" ^`r 4.,,;.a ..'it. ' ❑Not Observable ;extends over insulation. "'�'`_� p ❑Not Applicable i -' ', 402.2.4 ;Attic access hatch and door R- N R- ❑Complies [FI3]i 'insulation R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable • 402.4.1.2 Blower door test @ 50 Pa.<=5 ACH 50=_ ACH 50= ❑Complies [F117]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. i ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in :Not Observable tests,verification may need to DNot Applicable occur during Framing Inspection. 403.3.2 ;Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 ;determine air leakage with ft2 ft2 ❑Does Not • 'either: Rough-in test:Total 'leakage measured with a ❑Not Observable ;pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including !the manufacturer's air handler • 'enclosure if installed at time of 'test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system - • including the manufacturer's air handler enclosure. 403.3.2.1 ;Air handler leakage designated <'• Y... .::;. ,"„ }` `�;❑Complies [FI24]2 'by manufacturer at<=2%of e t ° ❑Does Not design air flow. { t^n "❑Not Observable ,,. - Whtt -'''❑Not Applicable 403.1.1 ;Programmable thermostats '' ry'n-4 ,, ❑Complies 1FI9]2 I installed for control of primary , ,t,I-1Does Not i I heating and cooling systems and s r' !initially set by manufacturer to _ -� • , „ �� r-; ;l❑Not Observable code specifications. a ;;- ;yr_: : : =�` :t,, )'❑Not Applicable 403.1.2 (Heat pump thermostat installed 4�_ ' a #..1 'i. ¢< 71`k]t❑Complies [FI10]2 Jon heat pumps. ,, --ri-r ~"`�❑Does Not �`=�:''a:-�"' -❑Not Observable i =i `` ;❑Not A'.- ". Applicable 403.5.1 Circulating service hot water �'-. �'. 4 " .•-_` '_'_ .- .;❑Com [FI11]2 'systems have automatic or :*,a:=` . =r --1.,,:?.;:,; s ;❑ pliet . T,*:.r • .... i Does Not ;accessible manual controls. 4 �~"-.,1,-, j' :<';, n - :"-= ,,,., - EINot Observable I -?:..J { ..... . ,_-iF.4 r:CNot Applicable :�``�_-ie} `'tom 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 403.6.1 {All mechanical ventilation system --.j;:' - >7 - '"'Via, ,, ...;., '.=-(❑Complies - [FI2572 ;fans not part of tested and listed -- 1?), `•`.. ,..", '. `.lt` =,.`�❑Does Not and1HVACair equipment meet efficacy ' ' !. , t-"2:- '❑Not Observable ` and flow limits. , . _',.:��- ` I 4 , ',4y .:a-` :,A;`- _ ❑Not Applicable 403,2 Hot water boilers supplying heat '`;; { ,', :. w t' -`= "❑Complies [F126]2 ;through one-or two-pipe heating .,^4 , -'- • 4? .r• _.-'-'in. Does Not . - : '1 !systems have outdoor setback -:�,- -� �(� ::f>�$��-:.- ,�❑Not Observable control to lower boiler water s°' .- _ • ;.; }▪ -;.'`;'> ;temperature based on outdoor '�f =six ` - . _t,v, * ` i❑Not Applicable ;temperature, i..tvi �.: ,4,._ -: ,k ,t.• --1 403.5.1.1 i Heated water circulation systems -` :.:L F` "`.j❑Complies [F128]2 ;have a circulation pump.The -': -- ' i=:-fy;.,a"s- ,1:_.;- i❑Does Not system return pipe is a dedicated t`' '7- =,7`�=•` -' - "' ''::.' '• - ;.. . `t,-, ';'❑Not Observable return pipe or a cold water supply{ t= r. _ pipe.Gravityand thermos- 'V '„. t;:f: e!' ,--N • ; :,❑Not Applicable syphon circulation systems are ` -:'.;_`? - not present.Controls for ?- ,=. •- T _``; ;;:'• ' `- ' ,circulating hot water system tv •�'�r;_-.,`==': ;;7': ;. ,: ' '_ 'I pumps start the pump with signal w` =�p1<; _;.-A-'..;. ': ",14..; ;for hot water demand within the :. •; .;. a` -;N_; ::•;^:r; .i occupancy.Controls 1.%a "€ I, �W ,automatically turn off the pump "' , .z Il. E ` when water is in circulation loop ''° :- , " ;_` • 3 I is at set-point temperature and ` --• == `° ., , , ;no demand for hot water exists. '.K=A4, '.-'. '�^1 403.5.1.2 E Electric heat trace systems ::'"f ` 'k; ' _T-r".ni❑Complies --; ='i,.r �'F�';mod ...7,.. [FI2912 ;comply with IEEE 515,1 or UL r '"t74"•:-7- * ❑Does Not ;515,Controls automatically 4, ., --; ' " + _ �� _;�� .•�4Y.,�.�. �• ;❑Not Observable ;adjust the energy input to the :- •-•- `. " ->' ', ❑Not Applicable 'heat tracingto maintain the '` ' ` fA*. �, r''`• pp Idesired water temperature in the k ' :7.:: 1': .Y !piping. i T' :7 w •, 403.5.2 ;Water distribution systems that 47:7 , ,-9_%.z1+:•-_,.: • ` - - :.- ❑Complies [F130]2 shave recirculation pumps that IS: .-, �, `•'`' f` '`❑Does Not ;pump water from a heated water , - ,r.; ,,- 4'1 ki ,t_3;__,, �,❑Not Observable ;supply pipe back to the heated �F v ; p �❑Not Applicable water source through a cold x�i;.xr��",�, ' ;water supply pipe have a .:, •= =;:::- � ;;_,F: y �::_ 1 _ ,demand recirculation water � ,;; 'cx,;;;'cif ;system, Pumps have controls -'; `; ;-.., '_ ; ,, ,,,, that manage operation of the = �,...•. .z•, �. :r21.,•,`3 .4,, i pump and limit the temperature . `. ',: ., s''•. : ,°.- ��. 1 of the water entering the coldL.,;,...si,,,,,,::;„,:..,.::.6,,:,,,,-- :;: rj, Iwater piping to 1042F, _,. ''k' '4-• ' .,' 403.5.4 Drain water heat recovery units .' .. ' .❑Complies [FI31]2 {tested in accordance with CSA '' , ", " u-r-i-!❑Does Not 1 B55,1,Potable water-side =: K^•`. ', ' Y""'- `t;%1 Not Observable pressure loss of drain water heat ,_".,..�,w,,,, ; ] I 's; A: Y `,,❑Not Applicable ;recovery units<3 psi for .,;" --t ,SI pp f .��,. ..s.ii�y5- .W Vie. '!�_ +'!.`:'��k.i..-f ;individual units connected to one "s;:, -.::; -' -" 4'�`rG .- `'~- or two showers.Potable water- "",¢..>'.,.. .-,-.;::; • '`" , side pressure loss of drain water • =fir; ' _:: „r-an q heat recovery units<2 psi for , ,•J ,< ^r�,. I individual units connected to ' • 7 1- ' 11three or more showers. ,;:•4 Y,�`:°' , .4� :x:. 4 404.1 75%of lamps in permanent 6-`h - ..• .b 4',_.. i'--- Ea- i❑Complies [FI6] fixtures or 75%of permanent r Does Not fixtures have high efficacy lamps. :` .. f I'',-` -�>.r',• `Z° Does not apply to low-voltage - ❑Not Observable lighting. „ ;DNot Applicable 404.1.1 Fuel gas lighting systems have 1 • OComplies [FI23]3 no continuous pilot light. �.` Does Not r i i❑Not Observable ' • IONot Applicable • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley Report date: 05/10/18 Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 8 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Re .ID 401.3 ICompliance certificate posted. '";- = ;❑Complies [F1712 i ! ❑Does Not :.. '❑Not Observable • In Applicable 303.3 ;Manufacturer manuals for . 1I0Complies [F11873 mechanical and water heating i a;"r /❑Does Not systems have been provided. f '& ❑Not Observable ,.4 J❑Not Applicable Additional Comments/Assumptions: • • • • • • • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Ilsley Report date: 05/10/18 • Data filename: C:\Users\kevin\Documents\REScheck\HILLTOP ILSLEY.rck Page 9 of 9 • V t t A t 2015 1ECC Energy Efficiency Certificate • Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 13.00 Floor 0.00 Ceiling I Roof 49.00 Ductwork(unconditioned spaces): - Glass&Door Rating U-Factor SHGC Window 0.26 Door 0.28 Heating&Cooling Equipment Efficiency Heating System: • Cooling System: Water Heater: Name: Date: Comments T h e rm a l A sso ciates 21 Thomson Ave. Glens Falls, NY 12801 518.798.5500 Fax 798.5620 Hilltop Construction 51 Crowley Road Hudson Falls, NY 12839 518-798-0338 W e, Thermal Associates, performed a blower door test on the project at 1055 SR 149 Queensbury, NY, to determine the air changes per hour, for Hilltop Construction Co. The result of the test is: ( 1,470 CFM50 x 60 Minutes) / (34,308 cubic ft.) = 2.57 ACH50 N1102.4.3.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less than seven air changes per hour (ACH) when tested with a blower door at a pressure of 33.5 psf (50 Pa) as verified using instruments and procedures specified in ASHRAE/ASTM E779. The test shall be conducted by a qualified person, who shall demonstrate competence to the satisfaction of the code enforcement official for the conduct of such tests. For the purpose of this section, ACH50 shall mean air changes per hour of infiltration into a house as measured with a blower door at 50 pascals of pressure, in accordance with ASHRAE/ASTM E779. Testing shall occur after rough in and after installation of penetrations of the building envelope, including penetrations for utilities, plumbing, electrical, ventilation and combustion appliances. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed; 2. Dampers shall be closed, but not sealed, including exhaust, intake, makeup air, back draft and flue dampers; 3. Interior doors shall be open; 4. Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling system(s) shall be turned off; 6. HVAC ducts shall not be sealed; and 7. Supply and return registers shall not be sealed. Adam DeVit Blower Door Tester Thermal Associates www.thermalassociates.com mom" _ (tie only) N 83°3g'p5"1N James & Elizabeth Carter '__---- wire fence remains Lake — Bk. 623, Pg. 947 GfICITAC Ke° 200.00' w Baldwin Comer 1� - eAdd ;1 t 4'augreach ins r f3 n LYcy prim :y r i f Qx 1 j ` - d s • _. -. N SITE LOCATIC}'N tU LOCATION MAP LU >` � U o � Co r z SITE _DE Val OPMENT DA 7 A � 3 S17E AREA: 2.45-AC (106,722 SF) ZONING REQUIREMENTS EXISTING CHANGE IN PROPOSED ZONE - MDR IMPERVIOUS IMPERVIOUS IMPERVIOUS (MODERATE DENSITY RESIDENTIAL) COVERAGE COVERAGE COVERAGE FRONT SETBACK - 30' BUILDING FOOTPRINT 0 SF 2,486 SF 2,486 SF f SIDE SETBACKS - 25' REAR SETBACK - 30' DRIVEWAY 0 SF 4,333 SF 4,333 SF o LOT WIDTH - 100' cc; MAXIMUM BUILDING HEIGHT - 35' PORCHES & DECKS 0 SF 298 SF 298 SF �--- MINIMUM PERCENT PERMEABLE - 509 WALKS 0 SF 60 SF 60 SF cly WASTEWATER SYSTEM DESIGN ,:�'L 3-BEDROOM RESIDENCE James & Elizabeth Carter � B k. 623, P 947 DESIGN FLOW - 110 GPD/BEDROOM TOTAL IMPERVIOUS 0 SF 7,177 SF 7,$30 SF SITE LOCATION SYSTEM DESIGN FLOW - 330 GPD NEIGHBORHOOD MAP SEPTIC TANK - PROPOSED 1,000 GALLON PERCENT IMPERVIOUS 0q 6.7� 6,7� PIPE-IN-STONE PRECAST CONCRETE EROSION & SEDIMENT CONTROL NOTES ABSORPTION TRENCHES, LEACH FIELD - PIPE-IN-STONE ABSORPTION TRENCHES PERMEABILITY 100� 93.3 93.3� Brian & Carole Farrell (3) TRENCHES 0 58 LF DESIGN PERCOLATION RATE = 1-5 M!N/IN - BEFORE ANY CLEARING OR GRUBBING OF THE SITE IS INITIATED, AND DURING EARTHWORK PHASES, B k. 5251 , P g. 100 EACH, 174 LF TOTAL APPLICATION RATE = 1.2 GPD/SF SEDIMENT CONTROL FENCE SHALL BE INSTALLED AS SHOWN ON THE PLAN. DIST. BOX ABSORPTION TRENCH AREA REQUIRED = 275 SF • AT THE CONCLUSION OF EACH DAYS WORK AND AFTER EVERY STORM EVENT, SEDIMENT CONTROL c� 2' WIDE ABSORPTION TRENCH REQUIRED = 138 L.F. FENCE AND ANY OTHER EROSION CONTROL MEASURES SHALL BE INSPECTED FOR FAILURES OR o INSTALL 3 TRENCHES AT 50 LF = 150 LF SEDIMENT ACCUMULATION. ANY FAILURE SHALL BE IMMEDIATELY CORRECTED. cv 1,000 GALLON PRECAST CONCRETE WI SITE SETBACKS • ALL BARE EARTH AREAS SHALL BE SEEDED AND MULCHED THIN 7-DAYS OF COMPLETION OF � J SEPTIC TANK POTABLE WATER SUPPLY IS ON-SITE WELL WORK IN THE AREA. ONLY AREAS WHICH AREA ACTIVELY UNDER CONSTRUCTION MAY REMAIN - MAINTAIN 50' MIN. SEPARATION BETWEEN REQUIRED FOR PROPOSED OPEN FOR MORE THAN 7-DAYS. ONCE CONSTRUCTION IS COMPLETED IN THESE AREAS, SEED WELL & SEPTIC TANK MDR ZONE HOUSE AND MULCH SHALL BE INSTALLED WITHIN 7-DAYS Z 61.0' 38 22===--� - MAINTAIN 100' MIN. SEPARATION BETWEEN WITHIN 500' OF M.H.W. OF ANY LAKE, POND, RIVER, STREAM OR WETLAND, NO LAND AREA, v3 59.0 35 25' WELL & ABSORPTION AREA FRONT 30 161 INCLUDING AREAS STOCKPILED WITH EARTHEN MATERIALS, WHICH HAS BEEN CLEARED, MAY BE 1 -® HOUSE SEWER Tp-1 WITH LEFT DEVOID OF VEGETATION FOR MORE THAN 24-HOURS OUT A PROTECTIVE COVERING — I SITE sOlts DATA SOU TH SIDE 25 26 SECURELY PLACED OVER THE ENTIRE AREA AND/OR EROSION CONTROL MEASURES PROPERLY ROpp,SET1 1 � TEST PIT INSTALLED TO PREVENT SEDIMENTS FROM ENTERING THE WATERBODY. ACCEPTABLE PROTECTIVE TP-I - 6121118 BY TOM HUTCHINS, P.E, WEST SIDE 25' 26' COVERINGS INCLUDE: NATURAL MULCH OF A DEPTH OF 2-INCHES, ROCK RIPRAP, a ,�' 0-4" - TOPSOIL NON-DEGRADEABLE MATERIALS SUCH AS PLASTIC OR CANVAS COVERINGS AND IMPERVIOUS o ' 4-29" - LIGHT BROWN FINE SAND REAR 30 385 STRUCTURES. 29-48 - LIGHT BROWN FINE AND MEDIUM SAND • TEMPORARY EROSION CONTROL MEASURES, INCLUDING SEDIMENT CONTROL FENCE ANDIOR MULCH, - _ --=_E=����-— SHALL BE INSTALLED AND MAINTAINED FOR ANY TEMPORARY S(�!L STOCKPILE AREAS THAT ARE TO -- --=- �`-£---=__=- NO GROUNDWATER EVIDENCE TO 48" BE LEFT FOR MORE THA 24-HOURS. _ ----_-______ • NO LAND AREA MAY B LEFT DEVOID OF VEGETATION FQR MORE THAN 7-DAYS WITHOUT A -- -....,.,,,,,,�_ PERCOLATION TEST STABILIZATION PROTECTIVE COVERING ECURELY PLACED OVER THE ENTIRE AREA AND/OR EROSION CONTROL — 0 53'3 fr 100 28� THE CONTRACTOR SHALL INITIATE STABILIZA 77ON MEASURES PT-I - 6/21/18 8Y TOM HUTCHINS, P.E. NEW WELL add MEASURES PROPERLY INSTALLED. N 81 53'39�tW 100281 STABILIZED PERCOLATION RATE; AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE FOR GROUND CLEARING ACTIVITIES OCCURRING BETWEEN OCTOBER 15 & APRIL 15, IN WHICH _ EXISTING NEIGHBORING WASTEWATER 1 MINUTE 5 SECONDS PER INCH VEGETATION CANNOT BE ESTABLISHED, EXPOSED EARTHEN AREAS SHALL BE COVERED W17H EITHER ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, shed SYSTEM, LOCATION APPROXIMATE BUT IN NO CASE MORE THAN 7-DAYS. A TARP COVER OR AN EXTRA HEAVY LAYER OF MULCH. I o - STABILIZATION OF GRASS AREAS INCLUDES HYROSEEDING • ANY AREA OF REVEGETA77ON MUST EXHIBIT A SURVIVAL OF A MINIMUM OF 807 OF THE ___ c USING TACKIFIER ON SLOPES AVER 1:5 OR SEEDING AND VEGETA7ON THROUGHOU THE YEAR FOLLOWING REVEGETATION. REVEGETA7E AS NEEDED TO LU _ � N C. Hack & R. Taylor co C\1 1 - stY• house I Bk. 4867, Pg. 293 INSTALLING A CONTINUOUS COVER OF STRAW MULCH • MEET THIS REQUIREMENT. CD P dd r t r o - WATERED INTO PLACE. ON SLOPES OVER 1:3 INSTALL THE CONTRACTOR SHALL I COMPLY WITH THE NEW YORK STATE STANDARD SPECIFICATIONS FOR EROSION AND SEDIMENT CON 7ROL (THE BLUE BOOK). oo n► EROSION CONTROL BLANKETS OR WOOD CHIPS IN .� © -� ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. §' o - Dwight IlsleyE L_F7, co N ;7 o , 1e oat `o Thelma IlsIey � I APR 1 201 0.374+d/— Ac. 0 E AS BUILT .............- RECORD T� 'N = ' (Bk. 1308, Pg. 38 ---= � INSTALLATION DATE: 11130118 TAX MAP # 266.4-1-3 EXIST. INSTALLED BY - CHARLES FRIEDMAN EXCAVATION WELL ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. N 81°44+33,�w 100 2 sp 144-1 8' To Ridge Rd. -_-=- E �. -- RECORD DRAWING NOTE: A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE N T�T1 DURING CONSTRUCTION AND IT IS MY OPINION THAT T ,�4 C� a- - THE SYSTEM IS INSTALLED IN GENEFAL CONFORMANCE ----- l� WITH THE APPROVED PLAN AND THIS RECORD 1 RECORD DRAWING 11 30�2018 DRAWING. FINAL SURFACE FINISHING AND TURF � ESTABLISHMENT REMAINS TO BE COMPLETED. 1 0 ISSUED FOR PERMIT 71212018 pp ng 143P G. THOMAS HUTCHINS, P.E. No. Revisions Data 11130,118 .)ITE & WASTEWA TER SYSTEM PLAN pp ng 144 prepared for SITE PLAN Dwight & Thelma Ilsley Dig OSafely. SCALE. � '=40' MAP REFERENCE State Route 149 New York f7 n u r�^ J� BASE SURVEY INFORMATION FROM "MAP OF A Town of Queensbury, Warren County, New York p Call Before You Dig GRAPHIC SCALE SURVEY MADE FOR DWIGHT & TNELMA ILSLEY OF --rw Wait The Required Time Drawn: JRS -�_ Checked: GTH Scale: NOTED Date: 6/5/2018 El Confirm Utility Response ren Respect The Marks 20 0 10 20 40 60 LANDS IN THETOWN OF QUEENSBURY, COUNTY 169 Haviland Road p Dig With care OF WARREN, STATE OF NEW YORK, DATED MAY NY 12804 800-962■7962 IN FEET } � 23, 2018. PREPARED BY JOHN F. GRADY, � .. �18 n745 y0307 Phone —� � � 291313-0�1 -S2 www.digsafelyneviyork.com LICENSED LAND SURVEYOR. Hutchins EE n g I n ee ri ng (518) 745-0308 Fox