Loading...
engineered details Title Block Line 1 Project Title: UpSlope Carport . You can change this area Engineer: SFUSA Engineering using the"Settings"menu item Project ID: and then using the"Printing& Project Descr:Free Standing Carport Title Block"selection. Title Block Line 6 Printed: 6 AUG 2018,11:42AM 2-D Frame File=F:\Solar\Carports\Carport2D Frame-UpSlope-Report.ec6 . Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 . Lic.#: KW-06009134 Licensee:Solar Foundations USA,Inc. Description: Carport(Upslope)-Apex Report(10) Joints... Joint Joint Coordinates Joint Label X ft X Translational Restraint Y Translational Restraint Z Rotational Restraint Temp degft F 0-0 -0.3320 8.598 0 1-0 0.0 0.0 Fixed Fixed Fixed 0 1-1 - 0.0 8.627 0 1-2 6.0 0.0 Fixed Fixed Fixed 0 2-3 8.966 9.411 0 4-1 21.283 10.489 0 Members... Member Endpoint Joints Member Releases Specify Connectivity of Member Ends to Joints Label Property Label I Joint J Joint Length x I Eyd z (rotation) x J End • z (rotation) B-Angle HSS3x3x1/8 1-1 1-2 10.508 Fixed Fixed Pinned Fixed Fixed Pinned MBeam0 HSS10x4x3/16 0-0 1-1 0.333 Fixed Fixed Fixed Fixed Fixed Fixed MBeam1 HSS10x4x3/16 1-1 2-3 9.000 Fixed Fixed Fixed Fixed Fixed Fixed MBeam2 HSS10x4x3/16 2-3 4-1 12.364 Fixed Fixed Fixed Fixed Fixed Fixed NPost1 HSS6x4x1/8 1-0 1-1 8.627 Fixed Fixed Pinned Fixed Fixed Pinned NPost2 HSS6x4x1/8 1-2 2-3 9.867 Fixed Fixed Pinned Fixed Fixed Pinned Member Stress Check Data... Member Unbraced Lengths • Slenderness Factors AISC Bending&Stability Factors Label Lu:z ft Lu:y K:z K:y Cm Cb 6-Angle 10.508 10.508 1.00 1.00 1.000 1.000 MBeam0 0.333 • 0.333 1.00 1.00 1.000 • 1.000 MBeam1 9.000 9.000 1.00 1.00 1.000 1.000 MBeam2 12.364 12.364 1.00 1.00 1.000 1.000 NPost1 8.627 8.627 - 1.00 1.00 1.000 1.000 NPost2 • 9.867 9.867 1.00 1.00 1.000 1.000 Materials... Member Youngs Density Thermal Yield Label ksi kcf in/degr ksi A500 29,000.00 0.490 0.000007 50.00 Default 29,000.00 0.490 0.000007 50.00 Steel 29,000.00 0.490 0.000007 50.00 Member Sections... Prop Label Group Tag Material Area Depth Width lxx lyy Default Group Default 1.0 inA2 0.0 in 0.0 in 1.0 in^4 1.0 104 HSS10x4x3/16 Group A500 4.670 inA2 10.0 in 4.0 in 57.80 inA4 13.90 in^4 HSS3x3x1/8 Group A500 1.30 inA2 3.0 in 3.0 in 1.780 in^4 1.780 in^4 HSS6x4x1/8 Group A500 2.230 inA2 6.0 in 4.0 in 11.40 in^4 6.150 in^4 Member Distributed Loads.... Note:Loads labeled"Global Y"act downward(in°'-Y"direction) • Member Load Load Extents Load Magnitude Label Direction Start ft Dead Roof Live Live Snow Seismic Wind Earth MB am0 Global Y EndO 0 Start Mag: 0.0570 0.3850 k/ft 0.330 End Mag: 0.0570 0.3850 k/ft MBeamO Global Y 0.0 Start Mag: 0.2370 k/ft 0.330 End Mag: 0.2370 k/ft MBeamO Global X 0.0 Start Mag: 0.0210 k/ft 0.330 End Mag: 0.0210 k/ft MBeam1 Global Y 0.0 Start Mag: 0.0570 0.3850 k/ft 9.0 End Mag: 0.0570 0.3850 k/ft MBeam1 Global Y 0.0 Start Mag: 0.2370 k/ft 9.0 End Mag: 0.2370 k/ft MBeam1 Global X 0.0 Start Mag: 0.0210 k/ft 9.0 End Mag: 0.0210 k/ft Title Block Line 1 Project Title: UpSlope Carport . You can change this area Engineer: SFUSA Engineering . using the"Settings"menu item Project ID: s and then using the"Printing& Project Descr:Free Standing Carport Title Block"selection. Title Block Line 6 Printed: 6 AUG 2018,11:42AM 2-D Frame File=F:\Solar\Carports\Carport2D Frame-UpSlope-Report.ec6. Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 . Lic.#: KW-06009134 Licensee:Solar Foundations USA,Inc. Description: Carport(Upsiope)-Apex Report(10) Member Distributed Loads.... Note:Loads labeled"Global Y"act downward(in"-Y"direction) Member Load Load Extents Load Magnitude Label Direction Start ft Dead Roof Live Live Snow Seismic Wind Earth MBgam2 Clobal Y End0.0 Start-Mag: 0.0570 0.3850 k/ft 12.360 End Mag: 0.0570 0.3850 k/ft MBeam2 Global Y 0.0 Start Mag: 0.2370 k/ft 1.520 End Mag: 0.2370 k/ft MBeam2 Global X 0.0 Start Mag: 0.0210 k/ft 1.520 End Mag: 0.0210 k/ft MBeam2 Global Y 1.520 Start Mag: 0.2610 k/ft 12.360 End Mag: 0.2610 k/ft MBeam2 Global X 1.520 Start Mag: 0.0230 k/ft • 12.360 End Mag: 0.0230 k/ft Strength/Stress Load Combinations ASCE 7-10 Load Combination Cd Load Combination Factors Description Dead Roof Live Live Snow Seismic Wind Earth +D+H 0.9 1.0 1.0 • +D+L+H 1 1.0 1.0 1.0 +D+Lr+H 1.25 1.0 1.0 1.0 +D+S+H 1.15 1.0 1.0 1.0 +D+0.750Lr+0.750L+H 1.25 1.0 •0.750 0.750 1.0 +D+0.750L+0.750S+H 1.15 • 1.0 0.750 0.750 1.0 +D+0.60W+H 1.6 1.0 0.60 1.0 +D+0.70E+H 0.9 1.0 0.7 1.0 +D+0.750Lr+0.750L+0.450W+H 1.6 1.0 0.750 0.750 0.450 1.0 +D+0.750L+0.750S+0.450W+H 1.6 1.0 0.750 0.750 0.450 1.0 +D+0.750L+0.7505+0.5250E+H 1.15 1.0 0.750 0.750 0.525 1.0 +0.60D+0.60W+0.60H 1.6 0.60 0.60 0.60 +0.60D+0.70E+0.60H 0.9 0.60 0.7 0.60 Reaction Load Combinations ASCE 7-10 Load Combination Load Combination Factors Description Dead Roof Live Live Snow Seismic Wind Earth +D+H 1.0 1.0 +D+L+H 1.0 1.0 1.0 +D+Lr+H 1.0 1.0 1.0 +D+S+H 1.0 1.0 1.0 +D+0.750Lr+0.750L+H 1.0 0.750 0.750 1.0 +D+0.750L+0.7505+H 1.0 0.750 0.750 1.0 +D+0.60W+H 1.0 0.60 1.0 +D+0.70E+H 1.0 0.70 1.0 +D+0.750Lr+0.750L+0.450W+H 1.0 0.750 0.750 0.450 1.0 +D+0.750L+0.750S+0.450W+H 1.0 0.750 0.750 0.450 1.0 +D+0.750L+0.750S+0.5250E+H 1.0 0.750 0.750 0.5250 1.0 +0.60D+0.60W+0.60H 0.60 0.60 0.60 +0.60D+0.70E+0.60H 0.60 0.70 0.60 . D Only 1.0 Lr Only 1.0 L Only 1.0. S Only 1.0 W Only 1.0 E Only 1.0 H Only 1.0 Deflection Load Combinations ASCE 7-10 Load Combination Load Combination Factors Description Dead Roof Live Live Snow Seismic Wind Earth +D+H 1.0 1.0 +D+L+H 1.0 1.0 1.0 +D+Lr+H 1.0 1.0 1.0 +D+S+H 1.0 1.0 1.0 +D+0.750Lr+0.750L+H 1.0 0.750 0.750 1.0 a Title Block Line 1 Project Title: UpSlope Carport ' You can change this area Engineer: SFUSA Engineering using the"Settings"menu item Project ID: and then using the"Printing& Project Descr:Free Standing Carport Title Block"selection. Title Block Line 6 Printed: 6 AUG 2018,11:42AM - 2-D Frame File=F:1Solar\Carports\Carport 2D Frame-UpSlope-Report.ec6 . Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 . Lic.#:KW-06009134 Licensee:Solar Foundations USA,Inc. Description: Carport(Upslope)-Apex Report(10) +D+0.750L+0.7505+H 1.0 0.750 0.750 1.0 +D+0.60W+H 1.0 0.60 1.0 +D+0.70E+H 1.0 0.70 1.0 +D+0.750Lr+0.750L+0.450W+H 1.0 0.750 0.750 0.450 1.0 +D+0.750L+0.750S+0.450W+H 1.0 0.750 0.750 0.450 1.0 +D+0.750L+0.7505+0.5250E+H 1.0 0.750 0.750 0.5250 1.0 +0.60D+0.60W+0.60H 0.60 0.60 0.60 +0.60D+0.70E+0.60H 0.60 0.70 0.60 D Only 1.0 Lr Only 1.0 Deflection Load Combinations ASCE 7-10 Load Combination Load Combination Factors Description . Dead Roof Live Live Snow Seismic Wind Earth L Only 1.0 S Only 1.0 W Only 1.0 E Only 1.0 H Only 1.0 Extreme Joint Displacements Only Load Combinations giving maximum values are listed Joint Displacements Joint Label X . Y Z in in - Radians 0-0 0.06015 0.001550 0.002835 . Max +D+0.750S+0.450W W Only '. +D+0.750S+0.450W 0-0 0.004228 .0000570 0.000208 Min +0.60D +0.60D +0.60D 1-0 0.0 0.0 0.0 Max +D+0.7508+0.450W 1-0 0.0 0.0 0.0 Min +0.60D 1-1 0.05916 0.01257 0.002835 Max +D+0.750S+0.450W +D+0.750S+0.450W +D+0.750S+0.450W 1-1 0.004155 0.000886 0.000208 Min +0.60D +0.60D +0.60D 1-2 0.0 0.0 0.0 Max W Only +0.60D 1-2 0.0 0.0 0.0 Min +D+0.450W +D+0.750S+0.450W 2-3 0.06770 -0.003296 -0.000621 Max +D+0.750S+0.450W +0.60D +0.60D 2-3 0.004767 -0.04554 -0.008467 Min +0.60D +D+0.750S+0.450W +D+0.750S+0.450W 4-1 0.2983 -0.1972 -0.001542 Max +D+0.750S+0.450W +0.60D +0.60D 4-1 0.02172 -2.683 -0.02097 Min +0.60D +D+0.750S+0.450W +D+0.750S+0.450W Extreme Joint Reactions Only Load Combinations giving maximum values are listed Joint Reactions Joint Label X Y Z ' k k k-ft • 0-0 Max Min 1-0 • -0.5533 Max +0.60D -7.854 Min +D+0.750S+0.450W 1-1 Max • Min ' • Title Block Line 1 Project Title: UpSlope Carport You can change this area Engineer: SFUSA Engineering using the"Settings"menu item Project ID: and then using the"Printing& Project Descr:Free Standing Carport Title Block"selection. Title Block Line 6 Printed: 6 AUG 2018,11:42AM 2-D Frame File=F:\Solar\Carports\Carport2D Frame-UpSlope-Report.ec6 Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 . Lic.#: KW-06009134 Licensee c Solar Foundations USA,Inc. Description: Carport(Upslope)-Apex Report(10) 1-2 0.0 17.783 Max +0.60D +D+0.750S+0.450W -0.4772 1.295 Min W Only +0.60D 2-3 • Max Min 4-1 Max • h Title Block Line 1 Project Title: UpSlope Carport You can change this area Engineer: SFUSA Engineering using the"Settings"menu item Project ID: and then using the"Printing& Project Descr:Free Standing Carport . Title Block"selection. Title Block Line 6 Printed: 6 AUG 2018,11:42AM 2-D F rarn a File=F:\Solar\Carports\Carport 2D Frame-UpSlope-Report.ecf Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 Lic.#:KW-06009134 Licensee:Sotar Foundations USA,- Description: Carport(Upslope)-Apex Report(10) Extreme Joint Reactions Only Load Combinations giving maximum values are listed Joint Reactions Joint Label X Y Z k k k-ft Min 1 Extreme Member End Forces Only Load Combinations giving maximum values are listed . Member"I"End Forces • Member"J"End Forces Member Label• Axial Shear Moment Axial Shear Moment k k k-ft k k k-ft B-Angle 7.014 0.0 0.0 -0.4919 0.0 0.0 Max +D+0.750S+0.450W +D+S D Only +0.60D +0+0.7505+0.450W D Only B-Angle 0.4919 0.0 0.0 -7.014 0.0 0.0 Min +0.60D +D+0.750S+0.450W • D Only +D+0.750S+0.450W +D+S D Only MBeam0 0.0 0.0 0.0 0.01269 0.1490 -0.001892 Max +D+S +0+0.750S+0.450W +D+0.7505+0.450W +D+S +D+0.750S+0.450W +0.60D MBeam0 0.0 0.0 0.0 0.000923 0.01124 -0.02507 Min +D+0.7508 +D+0.60W +D+0.60W +0.600+0.60W +0.60D +D+0.750S+0.450W MBeam1 -0.2938 -0.1356 0.02507 4.452 5.951 -2.602 Max +0.60D +0.60D +D+0.750S+0.450W +D+0.750S+0.450W +D+0.750S+0.450W +0.60D MBeam1 -4.182 -1.888 0.001892 0.3206 0.4423 -35.303 Min +D+0.750S+0.450W . +D+0.750S+0.450W +0.60D +0.60D +0.60D +D+0.750S+0.450W • MBeam2 0.4763 5.698 35.303 0.0 0.0 0.0 - Max +D+S +D+0.750S+0.450W +0+0.750S+0.450W +D+S +D+0.7508+0.450W +D+0.60W . . MBeam2 0.03561 0.4211 •. 2.602 0.0 0.0 0.0. Min +0.60D+0.60W +0.60D +0.60D +D+0.750S+0.450W +0.60D +D+S NPost1 -0.5533 0.0 0.0 7.854 0.0 0.0 Max +0.60D D Only D Only +D+0.750S+0.450W D Only D Only NPost1 -7.854 - 0.0 0.0 0.5533 0.0 0.0 Min +D+0.7505+0.450W D Only D Only +0.60D D Only D Only NPost2 12.608 0.0 0.0 -0.9344 0.0 0.0 • Max +D+0.750S+0.450W D Only D Only +0.60D +D+0.750S+0.450W D Only NPost2 0.9344 0.0 0.0 -12.608 0.0 0.0 • Min +0.60D +D+0.750S+0.450W D Only +D+0.750S+0.450W D Only D Only Extreme Member Forces Only Load Combinations giving maximum values are listed Mmbr Label Axial Dist from"I"Joint Moment Dist from"I"Joint Shear Dist from"I"Joint B-Angle -0.4919k 0.0ft 0.0k-ft 0.0ft 0.0k 0.0 ft Max +0.60D B-Angle -7.014k 0.0ft 0.0k-ft - 0.0ft 0.0k 0.0 ft Min +D+0.750S+0.450W MBeam0 0.01269k 0.3333 ft 0.02507 k-ft 0.3333 ft -0.000232 k 0.006801 ft Max +D+S +D+0.750S+0.450W +0.60D MBeam0 0.000101k 0.02040 ft 0.000102 k-ft 0.03401 ft -0.1490 k 0.3333 ft Min D Only +0.60D+0.60W +D+0.750S+0.450W MBeam1 4.452k 9.0 ft 35.303 k-ft 9.0 ft -0.1356 k 0.0 ft Max +D+0.750S+0.450W +D+0.750S+0.450W +0.60D MBeam1 0.2938k 0.0ft 0.001892k-ft 0.0ft -5.951k 9.0ft Min +0.60D +0.60D +D+0.750S+0.450W , MBeam2 -0.000717k 12.112ft 35.303k-ft 0.0ft 5.698k 0.0ft Max +0.60D+0.60W +D+0.750S+0.450W +D+0.750S+0.450W MBeam2 -0.4763k 0.0 ft 0.001050 k-ft 12.112ft 0.008458 k 12.112 ft Min +D+S +0.60D +0.60D NPost1 7.854k 0.0 ft 0.0 k-ft 0.0ft 0.0 k 0.0 ft Max +D+0.750S+0.450W NPost1 0.5533k 0.0 ft 0.0 k-ft 0.0ft 0.0 k 0.0 ft Min +0.60D NPost2 -0.9344k 0.0 ft 0.0 k-ft 0.0ft 0.0 k 0.0 ft Max +0.60D NPost2 -12.608k 0.0 ft 0.0 k-ft 0.0ft 0.0 k 0.0 ft Min +D+0.750S+0.450W • .i Title Block Line 1 Project Title: UpSlope Carport You can change this area • Engineer: SFUSA Engineering using the"Settings"menu item Project ID: and then using the"Printing& -Project Descr:Free Standing Carport Title Block"selection. Titlet Block Line 6 Printed: 6 AUG 2018,11:42AM 2-D Frame File=F:\Solar\Carports\Carport2D Frame-UpSlope-Report.ec6. Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 . Lic.#:KW-06009134 Licensee:Solar Foundations USA,Inc. Description: Carport(Upslope)-Apex Report(10) Member Stress Checks... Stress Checks per AISC 360-10&NDS 2012 Member Section Material Max.Axial+Bending Stress Ratios Max.Shear Stress Ratios Label Label Load Combination Ratio Status Dist (ft) Load Combination Ratio Status Dist (ft) B-Angle Group Stee +D+0.750S+0.450W 0.421 (PASS) 0.00 N/A 0.000 (PASS) 0.00 MBeam0 Group Stee +D+O.750S+0.450W 0.001 (PASS) 0.33 +D+0.7505+0.450W 0.003 (PASS) 0.33 MBeam1 Group Stee +D+0.750S+0.450W 0.985 )PASS) 9.00 +D+0.7505+0.450W 0.100 'PASS) 9.00 MBeam2 Group Stee +D+0.750S+0.450W 0.972 I PASS' 0.00 +D+0.750S+0.450W 0.096 PASS) 0.00 NPost1 Group Stee +D+0.750S+0.450W 0.118 PASS) 0.00 NSA 0.000 PASS' 0.00 NPost2 Group Stee +D+0.750S+0.450W 0.300 ,PASS) 0.00 NSA 0.000 PASS, 0.00 Title Block Line 1 Project Title: UpSlope Carport You can change this area Engineer: SFUSA Engineering using the"Settings"menu item Project ID: and then using the"Printing& Project Descr:Free Standing Carport Title Block"selection. • Title Block Line 6 Printed: 6 AUG 2018,11:42AM 2-D Frame File=F:\Solar\Carports\Carport2D Frame-UpSlope-Report.ec6. Software copyright ENERCALC,INC.1983-2018,Build:10.18.7.31 . Lic,#:KW-06009134 Licensee:Solar Foundations USA,Inc. Description: Carport(Upslope)-Apex Report(10) MBeam2 4-1 MBeaml 2-3 M:-- 0 14-1 • NP•st2 NP•st1 B-- gle 1-0 1-2 r- RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID: 309.10-1-10/Property Address:64 Main Street/Zoning:MS -,, ,,,,\ I- ;• G�� y .._ _ ,,, ,,, -,p-4, '' tw"".--9 S 1 11 I ,0 la r -I- I e :5. l 'o ;' JUL 302018 ', r nts -LLu- SolarEd SolarEdge Single Phase Inverters cr F For North America Li-I SE3000A-US/SE3800A-US/Sf5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US Z s rt,%• t 1 tj2Zc H 4 I i L 4 4 € 401 , . . .r t4 * t 6., 4 ... ., • • -4=,-,.;,it -, '''4,t li"' v1M..,.. q kti' .rizt: M.4....."--:_ _,a,xy.. .....,...+,.s.i'_ii.a.wac"_ +'A '�.,} .,, The best choice for 5olarEdge enabled systems " Integrated arc fault protection for NEC 2011690.11 compliance .. Rapid shutdown for NEC 2014 690.12 ' — Superior efficiency(98%) 1, - Small,lightweight and easy to install on provided bracket ' — Built-In module-level monitoring j _,4. Internet connection through Ethernet or Wireless ••• Outdoor and indoor installation - - - Fixed voltage inverter,DC/AC conversion only I Pre-assembled Safety Switch for faster installation" - ' optional revenue grade data,ANSI 07 "_ a USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-UK-ISRAEL www solaredge.us l L _ 9 RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID:309.10-1-10/Property Address:64 Main Street/Zoning:MS ,-.� Y., ki_,... � Sin& Ph 1s IIiw fteP .�, s for North America - 6 �' I , r ' SE3000A US!SE3800A US/SE5000A US/SE6000A US/ SE7600A-US/SE10000A-US/SE11400A-US I SE3000A-US 1 SE3800A-US I SE5000A-US [SE6000A-US]SE7600A-US l SE1000OA-US 1 5E1141/DAµUS" OUTPUT .,._,.._a-..e-.. ____._ -_- -._ Nominal AC Power Output 3000 3800 5000 GOOD 78p0 9980 @ 208V 11400 VA 10000 Q240V Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450 eaa 240V 10950(1a 24ov AC Output Voltage Min:Nom.Max i'1 i - • J 183-208-229 Vac AC Output Voltage Min:Nom:Max.iv 1 ✓ ✓ 211.240-264Vac AC Frequency Min:Nom:Max m 1 59.3.60-60.5 Hz Max.Continuous Output Current 12.5 16 27 @ ZaOV I 25 I 32 42 240V I 47.5 A GFDI Threshold II 1 A Utility Monitoring,'standing Protection,Country Configurable Thresholds Yes Yes INPUT Maximum DC PowerISTC) 4050 I 5100 I 6750 8100 I_ 10250 13500 T 15350 - -W Transformer-less,Ungrounded Yes Max.Input Voltage 50D Vdc Nom.DC Input voltage 325 @ 208V/350 @ 240V Vdc Max.Input Current") 9.5 I 13 1 ]5.5 fa 240V I 38 I 23 , 30.5@224OV I 34.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 97.7 98.2 I 98.3 98.3 98 98 98 ele CEC Weighted Efficiency 97,5 98 97 @ 208V 97.5 97 5 97 @ 208v 97.5 9E 98a24DV 97.50240V Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES __ Supported Communication Interfaces R5485,RS232,Ethernet,ZipBee(optional) Revenue Grade Data,ANSI C12,1 OptionaP'i Rapid Shutdown-NEC 2014 690.12 Yes __ STANDARD COMPLIANCE Safety UL17411 UL1699B,UL1998,CSA 22.2 • Grid Connection Standards 1E6E1547 Emissions FCC parti5 class B s_ ,__ ______ • INSTALLATION:SPECIFIC:ATIONS AC output conduit size/AWG range 3/4"minimum/16.6 AWG 3/4"minimum/8-3 AWG DC input conduit size/if of strings/ 3/4"minimum/1.2 strings/16-6 AWG 3/4"minimum/1-3 strings/ AWG range 14-6 AWG Dimensions with Safety Switch 30.5 x 32.5 x 10.5/ in/ (HxWxD) 30.5x 12.5 x 7,2/775 x 315 x 184 775 x 315 x 260 mm Weight with Safety Switch 51.2/23.2 1 54.7/24.7 88.A(40.1 lb/kg • . Natural convection Cooling Natural Convector and internal Fans(user replaceable) fan(user ,replaceable) Noise <25 <50 dBA Min.-Max.Operating Temperature -13 to 4140/-25 to 460(-40 to 460 version available!")) 'F/.0 Ringe Protection Rating NEMA 3R "'For other tegimtat settings please contact Solarrdge support MA higher current source maybe used;the inverter wlt limit Its input current to the vaturs stated. Iiliteveoue grade rnvetter r'N:SEt a icA414O(INN112(rot 760sW inverter:SE7600A•US002N11112) tit•40 version Mk SEena,A•U5000Nt1U41for 76004V InvetterSE7400A•US002I1Nt14), i.El0 � �'��' V t �:,� I�t�v,ilJt u A. ',4 l i. ..,.F. .s "� .ter 3i;. j' Ill.‘ .• .. 1 RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID:309.10-1-10/Property Address: 64 Main Street/Zoning:, MS -'-:‘,,- -.." .,, ,-•--.,-,_'",,,-,, - ' ,.....c..,-, '. ., ' • ..:"`'Au-4kt; v.'.,;',,,•_ ,, _ .1 El ••4+.:.,,,,,..:- '. r ,.... 4-2 gefierkdpv PaweGE UptilrEGRE',,z6F , - •1.,...,, • *-* - , • • , - • • •••viii --,:.•••• , I•ili.....e• ••11,`,-- • • Module Add-On For North America ., -1--- _.•-•.:;! e 4, P300 / P320 J P400 / P405 ,e 4 C) p . 1, . , (= I ' -,.. : — --' , . lilt,., •i' ,-:Tig. :, .. , - " i p, -.yt-:)iSto..--._c, .fk. 1,--,,Iti':'-1-1"';':, .. I .., ... ,, .,„,„•,,,..,..,,, , _ -_-0.*-.!,..4 -, ,4 "el, , A' 'N., •'/ .i"2.6Ittri'• ''',11,: td,..!'• 4 4f --4•.• - 4. - i , le ., • t,vionoti? ,..:1 ; * ,r, •,,,, , 1+14. • • ,t,!:it,;4• • ' , k 1r vor'ii'o,,13-_,.., / 4 1 r'' , I e-.'14;4' 1.f.1,•••tlf- A _ ,••;, f 1 $/' .." / i, 2; ''' '',' •:t.•-t`4'.' .''•'.,", ': -1'.'''l,1'.'' '••.•-:*", -' 7 '•:;'•;t 's•;ap , , ‘, ., 4- ..' .., ,'I,':••:-. k•:`-.1--:.0'.•.4,. . -,. - ..,.-.-, , , .-, - -c-I•e''''. '-'''''d'''" - ." ,,,,,- 4'-`C: •' i i••• ,,,,:,,,o*i.r.I‘,. iryt:il , - ,..\i',,,,l..44',' - `,k--'' - --tee,' ''..e i ' / ,,,,x,,,,-,*-,,I, , .? ...,. '. :-' , -• _ - -''Tr,.4r.p-;,,t1--,:- ' ,, '---.--:" P:41.#.k.j,,1/4,,"-4 .„',.., -.-- ,, ..,,,,I. t-- 7 ,-...„. .,.. ....,.4 / i-, .!, -.''','' . - ,„ti,''4.:Lr?C'r:7,,-. ,i-Tit, —' ty•- 1 ,' , -;0,0*.:,:i:::::t-i'' .t':;-.,j.:tot% -.?.:-,44-,;;;.1.,,. .--..:11.:,Y-, 'I.71: --, . ..-• "` -'-' i I .4,-,;.1•,..- i,-.4.,.;4'--.-F •••1.44.---,t;'.. , .t.c,,t„ 4. ...24 ..i.. . .,.. ' • • '.•"'f-74/4., 1- --. A''''-'4 •4.*.'• 2''.;.•*7f" • .i - •"."7 '*- , .., •••. '-;',.;• .70'' • ' -' ' - ; ' ,.•, -,.; . • %,"'ir,,AV•1•' 1 --- , : II PV power optimization at the module-level . . • 7 Up to 25%more energy I ,,- Superior efficiency(99.5%) 1 , i • , Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading i -- -',- Flexible system design for maximum space utilization . • - - ,-, Fast installation with a single bolt . . •_ _ _ . i - - Next generation maintenance with module-lever monitoring ,-.. 4' Module-level voltage shutdown for installer and firefighter safety - , . . •_ ,,, _ • • „„. _ - • , •„ _ __ , . .:,. . . _ - • uSA-CANADA-GERMANY-ITALY-f RANCE-JAPAN-CH1NA.-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL • 'www.solaredge.us i - - - ,4- -,: -- - • .. . - r" • •.-2- •• - - . •' 0.,•- . .. , ._ - - . p. _ 3 RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT . Tax Map ID: 309.10-1-10/Property Address:64 Main Street/Zoning:MS • Bel©r_ c q: S®i arEdge Powea° ®p i lust„,,, Module Add-On for North America P300 / P320 / P400 / P405 ._.. _ _____ P300 P320 .. ...._ _..- _ P400 —P405 (for 60-cell modules) (for high•power (for 72&96-tell (for thin film 60-cell modules) _ modules) modules) INPUT Rated Input DC Powertll 300 i 320 400 405 W Absolute Maximum Input Voltage 48 $0 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-8D 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 11 10,1 Adc Maximum DC Input Current 12.5 I 13.75 12.63 Adc Maximum Efficiency 99.5 Weighted Efficiency 98.8 qa Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) • Maximum Output Current 15 Adc Maximum Output Voltage I 60 L 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power I 1 Vdc Optimizer ___�•ar_ STANDARD COMPLIANCE _..� e _______ _--- EMC ve_- FCC Part15 Class B,IEC61000.6-2,IEC61000.6-3 _ Safety IEC62109-1(class II safety),UL1741 ' RoHS Yes INSTALLATION SPECIFICATIONS — Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters t Dimensions(W x L x H) 128 x 152 x 27.5/ 128 x 152 x 35/ 128 x 152 x 48/ mm 5 x 5.97 x 1.08 5 x 5.97 x 1,37 5 x 5.97 x 1.89 /in Weight(including cables) 760/1.7 830/1.8 1064/2.3 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated•MC4 Compatible Output Wire Length 0.95/3.0 j 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 •C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % towed SIC power of the module nodule of up to 45%power tolerance allowed • PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERP) Minimum String Length 8 10 18 . (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) • Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes or Orientations lai It Is not allowed to ow P405 with P000/P400/P000/P7001n one string. + '!.'l4lt '}Jug 3N o : .1 k r 18.+-'4.1 .�' t ,'R r 5" a ' I 1-----,---- AAIR�r a1 t11°FFtr4k' e o•' - I t 0 1.) d a .t7a. F , RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT -1 ' "Tax Map ID: 309.10-1-10/Property Address: 64 Main Street/Zoning:MS Mono YyMuitt Solutions . _,_.______. __ ._- _ -- _ li , ,,_, :.„... ,,,-1-.T F Ak, /\kA >CPLUr us+ ,, . . . . . ,, '1 aIt Li r - 60 CELL MONOCRYSTALLINE MODULE i 27I-295W - POWER OUTPUT RANGE Maximize limited space with top-end efficiency I. , It••.. • Up to 180 W/m2 power density .-* • law thermal coefficients forareaterenefgy production at high b operating temperatures MAXIMUM EFFICIENCYIi 0. Highly reliable due to stringent quality control I • Over 30 in-house tests(UV,IC,HF and many more) 1. �'Y"" ` t In-house testing goesweit beyond certification requirements f ---- • 100%EL double inspection - POSITIVE POWER TOLERANCE 1 : a-leading globcsi rnonvIaafarer of r1 _ t Certified to withstand challenging environmental .f 3 ncktgenerationphotovoltalapraduols n' '� ' conditions j we believe close cooperation With ,t-r .r. i. Yr' . 24t)QPawJndlood ••i, our partners is-critical to success With --''r;• _ • 254000 Pa wsnow load • p 'focal psesencooroundttlealohe,Irin❑ _ 'r "'- isabte to-provide excaplloria1 service - • 35 mm hail stones at 97 km/h 1 i f,•to each customer in each market and- t' - supplement our innovative. reliable - i .products with tire backirng of Trina . i j as a strong, bankable partner. We- ' are cornmitied to building strategic, 1 j mutually beneficial collaboration with installers,developers,distributors and { other partners as the backbone al our f shared success In driving Srrmarl Energy ' together. li Comprehensive Tannioiarlimtted ' products and system Certificates Www-tiinasoiar.com - . • JEC 61215/1EC 61730/UL 3703/IEC 61701/lEC 62716 4 L1NEAil PERtaltMANCEWARRANTY * ISO 9001:Quality Management System 1 sbreurroa,nws.r.•rv.sva.unekr.w+w.,�+mv • ISO 14001:Environmental Monagement System a ' M • 1S0 14064:Greenhouse Gases Emissions Verification / "_"•-..,r,.G,4_,,„ • • OHSAS 18001',Occupation health and Sniety Managen•c r.t 5Ysfr 4—'-'1 e(7911$ c.,,,r,e'l it'll', \l,('''''' A4, PV iCYC!...E' 6d9 clsie' `M " "�> L. `€ite.So1►ar Seers Energy Together - r r 1 RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT °l Tax Map ID: 309.10-1-10/Property Address:64 Main Street/Zoning:MS ' THE At 1 MAX. Pt us' MODUL:l . PRODUCTS POWER RANGE ELECTRICAL DATA(STC) TSM-D005A;08(11) ..275.295W Peak Power Wafls-Per(WM' 270 275 280 285 290 295 -T5M=DDOSA.05(I1) 270-290W Power Output Tolerance-Peus(W) 0-75 maximum PaxerVoflage-V.07(V) 31.2 31.4 31.7 31.8 32.2 32.5 Maximum Power Currant-Iwr(A) 8.66 8,76 8.84 8.97 9.01 9.08 DIMENSIONS OF PV MODULE Open Circuit Voltage-Vac(V) 38.4. 38.7 39.0 39.3 39.5 39.7 unit:mm/Inches Short Circuit Current-he(A) 9.18 9.26 9.35 9.45 9.50 9.55 IS v.uara 16.5 16.8 17.1 17,4 17.7 18.0 Module Efficiency Om MI _� Mcrae Do. it; SIC:Irradiance 100D W/m•,Cell Temperature 2S•C,Al,Most AMI.S. 4i9`t2 'Test tolerance:e3T.. I n�-' nanectet - III $ ELECTRICAL DATA(NOCT) kMaximumPower-Prux)Wp) 201 205 209 212 216 220 R As JA Maximum Power Vol)age-Vwr{VI 28.9 29.2 29.4 29.6 29.9 30.2 - 3 i Maximum Power Current-bee(A) 6.96 7.02 7.10 7.17 7.23 7.28 b OS Open Circuit Voltage-Voc(V) 35.7 36,0 ; 36.3 36:6 36.7 36.9 ao+a Short Circuit Current-bc IA) 7.41 7.48 7.55 7.63 7.67 7.71 Owning tide NOCr:trradlaneo at800 Wm*.Ambient Temperature 20•C,Wind Speed 1 m/s. 12�ort lick f a a MECHANICAL DATA Iwn Solar Cells Monocrystalline 156 x 156 mm(6 inches) e evie., Cell Orientation •60 cells(6 x 10) Module Dimensions 1650 x 992.35 mm)65,0 x 39.1 x 1.38 inches) st:cnsodont Weight 18.6 kg(41.016) II/0A3 • Lari,lolo Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass g( 8acksheei White(DD05A.08(11));Black(DM/SA.050)i F3 Frame Black(DDOSA.08)II),ODO5A,05(11)) franc ` ,I•Box IP 67 or II'68 rated , /t•� Cables Photovoltaic Technology Cable 4.0mm'(0.006 inches'), Ads 1000 mm(39.4 inches) Connector MC4 Compatible or Amphenol H4/01X Fire Type Type 1 or Type 2 I-V CURVES OF PV MODULE(295W) 11 = . •_ TEMPERATURE RATINGS MAXIMUM RATINGS s " I f -----_. Nominal Operating Cell Operational Temperature -40-485°C r - Temperature(NOCT) 44°C11 2°C) •II N �.m-, 1000V DC BEG) 4 Temperature Coefficient Cl Pru, -0.399a/°C Maximum System Voltage 1000vpc tut) s ;••1_--_w .z-_-:- `-• TemperatureCoetficientofVon -0.29T/°C _ ..,. � Max Series fuse Rating 15A _ M1Yr Temperature Coefficient 0.05%/°C . 0 & 11 11 f0 IS 16 T5 •! 45 - ....'see--=xae.a rz°a-•�.e�+et,-.-xv.. 10,,o ra •WARRANTY P-V CURVES OF PV MODULE(295W) 10 year Product Workmanship Warranty 25 year Linear Power Warranty 4:41. 7sa (Please referlo product warranty for details) 1w 'it �n m - ` - - PACKAGING CONFIGURATION I o Modules per box:30 pieces z � tu Modules per 40'container:840 pieces P 1 ,, ,1 PP PP P:,..--. .4: warm Pr_ '_".."�'.�'y= e-s•-..------..-s.,--yam'-----,- r-°.,r.-.rv,,o-.+A.,--r,.�..=.- zs+-ae-s--- - -..r...e.--.s•-•-m1""",-,`, �.,_ CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 7, , 02016 Trine Soler limited.All rights reserved.Specifications included in this datasheetom subjectlo change without notice. IMUL So car Smart Energy Together RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID:309.10-1-10/Property Address: 64 Main Street/Zoning:MS WPLEDI3/PCS RAB LIGHTING LE COPY U Project: 1 Type: I Prepared By: t Date: i I rY F I _ Driver Info LED Info I Type: Constant Current Watts: 13W I - t 120V:. 0.13A Color Temp: 5000K(Cool) d : { 208V: NIA Color Accuracy: 67 CRI a 240V; N/A L70 Lifespan: 100000 277V: N/A Lumens: 1530 S Input Watts: 15W Efficacy: - 101 LPW 'i LED 10W&13 Walipacks.Patent Pending thermal managementsystem.100,000 hour L70 Efficiency: 86% I tifespan.5-year,no-compromise warranty. t Color:Bronze Weight 3.31bs '- - - - --- -_ - } i Technical Specifications i Listin s i 9. __-- __ _ Color__.. Color Uniformity: Pho#ocell: 1 UL Listing: RAB's iange of CCT(Correlated Color Temperature) 120V Swivel Photocell Included.Photocell is only Suitable for Wet Locations as a Downlight.Suitable for follows the guidelines of the American National compatible with 120V. ' Damp Locations as an Uptight.Wall Mount only. Standard for Specifications for the Chromaticity of Other Suitable for Mounting within 4ft.of ground. Solid State Lighting(SSL)Products,ANSI C78,377- - - --- --^W= _------A ! 2017, Patents: - Dark Sky Approved: Construction The design of the LPACK is protected by U.S.Pat. The International Dark Sky Association has approved "�" " "'-"----'=""--—""— _" D604,004 and patents pending in Canada,China and this product as a full cutoff,fully shielded luminaire Cold Weather Starting: Taiwan. IESNA LM-79&IESNA LM-80 Testing: Minimum starting temperature is-40°C(-40•F) Warranty: r RAB LED luminaires and LED corn onents have been Maximum Ambient Temperature: P RAB warrants that our LED products will be free from tested by an independent laboratory in accordance' Suitable for use in 55°C(131°F)ambient temperatures defects In materials and workmanship for a period of with IESNA LM-79 and LM-80. five(5)years from the date of delivery to the end user, Finish: # LED Characteristics including coverage of light output,color stability,driver "" Formulated for high-durability and long lasting color performance and fixture finish,RAB's warranty is Lifespan: subject to all terms and conditions found at 100,000-hour LED!trepan based on 1ES LM-80 Green Technology:an Mercuryand UV-ffree.RoHS compliantEquivalency: results and TM-21 calculations Polyester powder coat finish formulated without the Equivalent to 100W Metal Halide 4 Color Temperature(Nominal CCT): use of VOCs or toxic heavy metals. 5000K HID Replacement Range: For use on LEED Buildings: Replaces 70-150W Metal Halide Lumen Maintenance: IDA Dark Sky Approval means that this fixture can be o used to achieve LEED Credits for Light Pollution Buy American Act Compliance: The LED will deliver 70/o of its initial lumens at 9 i 100,00D hours of operation Reduction RAB values USA manufacturing!Upon request,RAB i' Electrical maybe able to manufacture this product to be { Color Consistency: ..-_....e.,..n.r �.R.,.n.-.,,-,P. ..: .-R-r-_---= compliant with the Buy American Act(BM).Please 1l 7-step MacAdam Ellipse binning to achieve consistent Driver: contact customer service to request a quote for the fixture-to-fixture color Multi-chip 13W high output long life LED Dr'- product to be made BAA compliant. s Color Stability Constant Current,Class 2 100V-277V,501.0 Id _ LED color temperature is warrantied to shift no more Surge Protection: q � f`"' ��,fs y, s.. G than 240K in GCT over a 5 year period 4kVp, + ii:j"' 1-4t*ThI.17'''''''-'--'-'. i 1 . Need help?Tech help fine:(888)RAH-1000 Email:sales d?rablighting.corn Website:www.rablighting.cont Page 1 of 2 Copyright t 2018 RAB Lighting inc.Ail Rights Reserved Note'Specifications are subject to change at any time without notice 11 Page 1 of 2 RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID: 309.10-1-10/Property Address:64 Main Street/Zoning:MS WPLED13/PCS Rl� Dimensions . Features roul� - _ Surhx Mount High performance LED light engine Configuration Maintains 70%of initial lumens at 100,000 hours pvod —� trPWeatherproof high temperature silicone gaskets • 1----01'-1 . r � i I�7�'1 t lam Superior heat sinking with die cast aluminum housing and external fins i r,....1 5-Year,No-Compromise Warranty * r 3- It„n(' I (lM71i 4. LIl M] t Con6gumfon 1.4. lui7u 1. A/a I I ';i �tti • 14i-4-— I i 4 i I 4 I . .I:__ L-Ilg o](j Ordering Matrix Family Wattage Color Temp Sensor Surface Plate Surface Place . Finish . Photocell Other Options WPLED 10= Blank=5000K Blank=No Blank=No Surface S=Surface Blank= Blank=No USA=BAA ' ' 10W (Cool) Sensor Plate Plate Bronze Photocell Compliant 13= Y=3000K(Warm) MS=Mini Sensor W=White /PC=120V Button Blank=Standard 13W N=4000K(Neutral) /PCS=120V Swivel IPC2=277V Button • • • • Need help?Tech help line:(888)RAB-1000 Email:sales@rablighting,com Website;www.rablighting.com Page 2 of 2 Copyright C0 2018 RAB Lighting Inc.All Rights Reserved Note:Specifications are subject to change at any time without notice . Page 2 of 2 r RESOLUTION -Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID: 309.10-1-10/Property Address:64 Main Street/Zoning:MS WPLED13/RCS RAB LIGHTING I. Project: ti Type: Prepared By: I Date: rit//////////////////////titama4,____ • , _ I-, ,y,�w_ .__-. Driver Info LED Info f i Type: Constant Current Watts:- 13W i } f + 120V: 0.13A Color Temp: 5000K(Cool) : 208V: N/A Color Accuracy: 67 CRI i . , 240V: N/A L70 Lifespan: 100000 277V: N/A Lumens: 1530 9 Input Watts: 15W Efficacy: 101 LPW LED 10W&13 Wallpacks.Patent Pending thermal management system.100,000 hour L70 Efficiency: 86% f • lifespan.5-year,no-compromise warranty, Color.Bronze Weight:3.31bs ---- -- --- - - -_----- -• -- •= - _—-- - ' -_- .M- Technical Specifications --_ - ._....- __ -- IListings= — ,yam- _,___y Color Uniformity: Photocell: 1 UL Listing: RAB's range of CCT(Correlated Color Temperature) 120V Swivel Photocell Included.Photocell is only Suitable for Wet Locations as a Downtight.Suitable for follows the guidelines of the American National compatible with 120V. jDamp Locations as an Uptight.Wall Mount only. Standard for Specifications for the Chromaticity of Other • Suitable for Mounting within 4ft.of ground. Solid State Lighting(SSL)Products,ANSI C78.377- - I I 2017. Patents: Dark Sky Approved: Construction The design of the LPACK is protected by U.S.Pat. The International Dark Sky Association has approved -'"a' =`__ ;_ ` "° s D604,004 and patents pending in Canada,China and this product as a full cutoff,fully shielded luminaire Cold Weather Starting: Taiwan. IESNA LM-79&IESNA LM-80 Testing: Minimum starting temperature is-40°C(-4o'F) Warranty: RAB LED luminaires and LED components have been Maximum Ambient Temperature: RAB warrants that our LED products will be free from t tested by an independent laboratory in accordance Suitable for use_ in 55'C(131°F)ambient temperatures defects in materials and workmanship for a period of with IESNA LM-79 and LM-80. five(5)years from the date of delivery to the end user, LED Characteristics Finish: including coverage of light output,color stability,driver ""'a "' — Formulated for high-durability and long lasting color performance and fixture finish.RAE's warranty is Lifespan: subject to all terms and conditions found at 100,000-hour LED lifespan based on lES LM-80 Green Technology: Mercuryand UV-free.RoHS corn compliant components, .Equivalency: results and TM 21 calculationsp' Polyester powder coat finish formulated without the Equivalent to 100W Metal Halide Color Temperature(Nominal CCT): use of VOCs or toxic heavy metals. 5000K HID Replacement Range: For use on LEED Buildings: Replaces 70-150W Metal Halide I Lumen Maintenance: IDA Dark Sky Approval means that this fixture can be Buy American Act Compliance: The LED will deliver 70%of its initial lumens at used to achieve LEED Credits for Light Pollution 100,000 hours of operation Reduction q RAB__- vlcY-« may valueseUSA manufacture this rodu t bet,RAB Electrical may be able to manufacture this product to be Color Consistency: compliant with the Buy American Act(BAA).Please i 7-step MacAdam Ellipse binning to achieve consistent Driver: contact customer service to request a quote for the fixture-to-fixture color product to be made BAA compliant. j Multi-chip 13W high output long life LED Driver Color Stability: Constant Current,Class 2 100V-277V,50/60 Hz I LED color temperature is warrantled to shift no more " Surge Protection: than 200K in CCT over a 5 year period 4kV • Need help?Tech help fee:(888)RA8 b000 Email.sales@rablighting.com Website:www,rablighting.cont Page 1 of 2 Copyright(D 2018 RAB Lighting Inc.Alt Rights Reserved Note.Specifications are subject to change at any time without notice • Page 1 of 2 { RESOLUTION-Grant Site Plan Approval SITE PLAN 38-2018 MARVIN DOBERT Tax Map ID: 309.10-1-10/Property Address:64 Main Street/Zoning:MS WPLEDI 3/PCS L,RA,B Dimensions Features �` High performance LED light engine 1.+'tl _ S Mount 1 Codigur8gurafon it Maintains 70%of initial lumens at 100,000 hours tong -OP^ —1 eil Weatherproof high temperature silicone gaskets I- 123sH1 Superior heat sinking with die cast aluminum housing and externalfins C� 5-Year,No-Compromise Warranty L l o , it 1 lniq , ( pM; L1 _J , 4. �0i0t1 Jurtion Bat Maxd li Con6puraron torn 1+. .stf-+ + t I }a ` h , rr 1 OM . Ordering Matrix Family Wattage Color Temp Sensor Surface Plate Surface Place Finish Photocell Other Options WPLED ' 10= Blank=5000K Blank=No Blank=No Surface S=Surface Blank= Blank=No USA=BAA ' 10W (Cool) Sensor Plate Plate Bronze Photocell Compliant 13= Y=3000K(Warm) MS=Mini Sensor W=White /PC=120V Button Blank=Standard 13W N=4000K(Neutral) /PCS=120V Swivel 7 /PC2=277V Button I. • • Need help?Tech help line:(888)RAB-1000 Email:sales@rablighting.com Website:www.rablighting.com Page 2 of 2 Copyright e•2018 RAB Lighting Inc.All Rights Reserved Note:Specifications are subject to change at any time without notice Page2of2