Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2009-040
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20090040 Date Issued: Wednesday, September 08, 2010 This is to certify that work requested to be done as shown by Permit Number P20090040 has been completed. Location: AMY Ln Tax Map Number. 523400-308-006-0001-015-000-0000 Owner. MATTHEW & SAMMANTHA BALL Applicant: MATTHEW BALL This structure maybe occupied as a: Fireplace By Order of Town Board Garage - 3 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090040 Application Number. A20090040 Tax Map No: 523400-308-006-0001-015-000-0000 Permission is hereby granted to: MATTHEW BALL For property located at: AMY Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MATTHEW& SAMMANTHA BA 5 ALGONQUIN Dr Fireplace QUEENSBURY,NY 12804-0000 Garage-3 Cars Attached Single Family Dwelling $150,000.00 Total Value $150,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-040 3218 sq ft single family dwelling with 891 sq ft attached garage with 1 fireplace $475.26 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, March 23, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn o ee l ,March 23,2009 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement I. .., r. OFFICE USE ONLY . ....f TAX MAP NO.- - ; PERMIT NO. •. — // " FEES: PERMI R CREATION �+ !.I ENGINEERING " ' R/NC L STRUCTURE; APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: f� - OWNER: ADDRESS: 6 01 Kj ADDRESS: PHONE NOS. jj- S PHONE NOS . CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? Q/yES ❑ NO IF SO, INDI E APPLICATION NO. ATE OF OVAL: PLEASE INDICATE MEASUREMENTS AS REQ LOW: CHECK ALL THAT Z APPLY TO YOUR Z 0 X d o (- PROJECT 0 00 O (n w WIW- U- emu- = Q 0, Hu_ (L2od SINGLE FAMILY 2{y � ✓� tt TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE + (� BUSINESS OFFICE RETAIL- MERCANTILE i I FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2 OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST:_ FUEL TYPE: " HEAT TYPE:Nt/ i+P,-HOW MANY FIREPLACE(S):_L_AND/OR WOODSTOVES(S): ZONING CATEGORY:<SR—I)q ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? IUO PROPOSED USE OF BUILDING OR ADDITION: `Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office Town of Queensbury - Community Development Office - 742 Bay Road, Queensburl, NY 12804 B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? _ �v ARE THERE EASEMENTS ON PROPERTY V U I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have re d agree the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) r----------------------------------- o Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building oo herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: , , , , 0 , , JBI G & CODE A ROYALZONING APPROVAL T DATE 01 QUESTIONS? CALL 761-8256 OR EMAIL _codes0mueensbury net _Office Use Only VISIT OUR WESSITE FOR MORE INFORMATION Operating Permit Issued: Yes No www.queensbury.net Occupancy Type: _ �� Construction Classification: Assembly Occupancy Limit: Special Conditions: Tozvn of Queensbury • Communihj Development Office ■ 742 Bay Road, Queensbury, NY 12804 For an EPA homeowner's guide: http://www.er)a.ciov/nr)des/pubs/homeowner guide long customize.odf DFFICE USE ONLY +___a_________________- 0 i; TAX MAP NO. PERMIT NO. �O PERMIT FEE �: , APPROVALS: ZONING TOWN CLERK + + ___=__aaaaaaaaa_a___a_aaaa__aa_aa____a_a________aasaaaa_aaa_aaasa____ +________:____________s APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.OWNER:// /a / y 1 f t INSTALLER: kg/� ADDRESS: ,5AvAay,%uiy7 ADDRESS: PHONE NOS. C/ /L1 j PHONE NOS. ( �f LOCATION OF INSTALLATION: Mc r►i ( . '� ' RESIDENCE YEAR BUILT NO.OF X COMPUTATION= = TOTAL DAILY FLOW INFORMATION: BEDROOMS 1980 or older Q X 150 gallon per bedroom = 0 GARBAGE GRINDER INSTALLED? 1981-1991 Q X 130 gallon per bedroom = 0 1992-present X 110 gallon per bedroom = SPA OR HOT TUB INSTALLED?. PARCEL INFORMATION: ✓ TOPOGRAPHY: FLAT ROLLING STEEP SLOPE SLOPE % ✓ SOIL NATURE: SAND LOAM CLAY OTHER ✓ GROUNDWATER: AT VNiAT DEPTH? �r BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WA SUPLY: MUNICIPAL WELL (If well:water supply from any septic system absorption is:( ft) I �J ✓ PERCOLATION TEST: RATE IS/ /VI 1 i , , PER MIINUTE PER INCH(TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: AN individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). TANK SIZE: /07 5 GALLON(MIN. SIZE IS 1,000 GAL.)Add 250 gallons to the size of septic tank for each garbage grinder, spa or whirlpool tub. Qi SYS TYPE: / BSORPTION FIELD(WITH NO. 2 STONE) Total lengt#aft. Each trench WX ❑SEEPAGE PIT(S)(WITH NO. 3 STONE) How many? Size? _ ❑ALTERNATIVE SYSTEM Bed or other type? Q.�K�F r=<EL ❑HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fad or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree QUESTIONS? CALL 761-8266 OR EMAIL to abide by these and all requirements of the Town of Queensbury codesO-aueensburv.net Sanitary Sewage Disposal Ordinance. // VISIT OUR WESSITE FOR MORE INFORMATIONry� J� www.aueensbu .net Si nature of Person Responsible bate Town of Queensbury• Community Development Office■ 742 Bay Road, Queensbury, NY 12804 Ore Marshal's O.face Q�Toiwn �1 Qazeen,bur`I a 742 Bay Rood• , Queens-bury. Aeus York •12804 t � ?Michael j.Palmer,.Fire klarsiuzl. Gary ttilln117n,Deputy Fire,"arsjtal j}A , x ------------ APPLICATION , FOR FUEL BURNING AppLIANCE & CY Application is hereby made to the Building&Codes Office for the issuance of a BuildingS Pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agreesto comply with all applicable laws, ordinances,regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORT/A�4TN�O/T TTO' }APP�L^ICANT• ROUGIa IN AUr%F1-1 INSPECTIONS ARE REQUIRED OWNER:///(/Tit/I /f s"Jlmm P J / INSTALLER/BUILDER: Q ADDRESS: 1► Ulf)l/11 r ADDRESS: r ^1 -✓II ul// f�. PHONE NOS. ! PHONE NOS. Xf LOCATION OF PROPERTY: dll,?Pj , - SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: 41 _ J gl� eOIOM " CONTACT PERSON FOR BUILDING 8 CODES COMPLIANCE://'(// f ra/ b PHONE: ✓ FUEL BURNING APPLIANCE INFORMATION WOOD COAL PELLET GAS OIL srovE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE(GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME:,(,{ K—/� MODEL NO#O DV 84 LISTED BY: NUMBER: QUESTIONS? CALL 7614205 or 761-8206 CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL: MASONRY** CHECK ONE ✓ firemarshal ueensbu .net VISIT OUR WEBSITE TILE STEEL SIZE IN FOR MORE INFORMATION INCHES MM.aueensbunr net FLUE CHECK ONE ✓ DOUBLE WALL TRIPLE WALL INSULATED DIRECT VENT CHIMNEY CHIMNEY MATERIAL CHECK ONE ✓ LINER **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm Depart: S am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT LOCATION: _ DATE: TYPE OF STRUCTU : _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location. Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railin s 34 in.to 38 in. Platform at all exterior doors oe Interior Handrails stairs 2 or more risers -74 Enclosed Stairs Sheetrock Underside minimum 'i/2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site �^r Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler � �,,,��� '►'1� Ask- Interior Relief Valve(s)installed/Heat Trap/Water Temp110 L. ' rivac /trim/doors/main entrance 36 in. r�� Bathroom/Kitchen watertight 1 Safe lzin /Windoviin stairwells safety zip Interior Smoke Detec rs: / Every level: / Ev ry Be bom: / Outside every bedroom a a: s// y Inter Connected: / Battery backup: Carbon Monoxide Detector 14,001 Bathroom Fans,if no window 9 Plumbing fixtures a01 Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insm form 2.docLast printed 2/12/04 A Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: 6" NAME: . � PERMTr NO.: o 4o L ON: �i]ZAALA. _-11h D- INSPECT ON: Comments and/or diagram Soil T Loam Clay T of Water: We 1 Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/- Y N N/A 150'to well required if NO Absorption Field: Total length ft. Length of each trench ft. T'� AK- � + xz Depth of trenches ft. Size of Stone Seepage Pits: Number Size: Stone Size: Piping ze T Building to tank Tank to Distribution Box 4�t Distribution Box to Field Pit Opening Sealed: N End Cap N In Outfit Pipes&Baffles t 1 Manholes 12"or less below grade Y ��'Ylr-- [provide extension collar if Yesl Y N Location Separations Foundation to tank t t ft. Foundation to absorption j7L— Separation of Pits A- Conforms as per P Y N Engineer Report an AS-B ' Y N ETU Maintenance ct Y_N provided Location of System on Property: Front ear Left Si Right Side Middle Front Middle Rear m S Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Bu11d1ng Codes Fonns\Inspectlon Fon'ns\Sepdc Irspecbon Report-03 2910.doc 601 601 60'L 20' 37, 2'5" 11' PVC D-BOX 22'OFF HOUSE 9'2"SEPTIC TANK HOUSE 0)vc T - P7- 2-- Z/ % Queensbury Building & Code Enforcement - R en'tial Final Inspection Office No. (618)761-6256 Arrive: am/pm Depart:. m/pm Date Inspection request ived: Inspector's Initials: NAME: PERMIT#: LOCATION: q DATE: TYPE OF STRUCTURE: Comments:, e Building Number Address visible from road )Dk�� C / Chimney Height/'W Vent/Direct Vent Location Fresh Air Intake ary o 14�� 0-4 3 inch Pkwnbina Vent thrmgh roof minimum 6 inches Roof C /Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers % � �� ., Guards at stairs decks hes more than 30 ind above grade �o �� 0.1' — Guard at staMkeli at 34 inches or more Guard at es 38 inches or more Handrail Termination at Newell Post or Wall lnterforlEx*W Railings 34 inches to 38 inctm Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plale Gas Valve shut-off wposed/Mulator 18 inches above grade � Interior privacy/birn/doors/main entrance 36 inches Bathroom/Kitchen ht Sa /WInd6w in oWwwob safety Interior Smoke De ors/ arbon onoxid Every level: E ry Bed Outside every bed area: Inter Connected: Batt beckue 7 Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 M.ft..-1 60 sq.ft.vend Baftoom Fans if no vdndow Plumbing fixtures Foundation instillation/Insulation Certification Flom truss draft stopping finished basement 1 000 sq.ft. Emergency earess below grade Gas Fumaoe shut-off within 30 feet or within line of site ON Furnace shut-off at entrance to furnace area Fumac WHot Water Heater op2gft Low water shut-off boiler Relief Valves Installed/Heat Tra W Water Temp 110 Enclosed Stairs Sheetrock Underside minimum Gypsum Basement stairs dosed rise>4 inches Garme Floor Pitched Gareas fireproofing I'/.hour fire door/door.closer Duct work Sealed properly Gas In Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan I Are Fault Breaker in Bedrooms z FimpemPips Bondina oAs Bui System i Sewer Dept. Inspection Sticker lam, n /Variance Lvgtfted --- Flood Plain Certification,if required Okay to issue C/C or C/ Temporay/Permanent LABuilding&Codes Forms%Building&Codesunspedion FormsWesidentlal Final Inspection F'onrh_revised_100405.doc;Revised January 7,2008;Revised WWI ' b Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart:-1 k 44:�� am/pm 742 Bay Rd., Queensbury, 12804 Inspectors Initials: e NAME: PERMIT NO.: ' LOCATION: INSPECT ON: — RECHECK: Comments and/or diagram Soil Type: / Loam Clay Type of Water: tun' I Well Water Waterline separation distances ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/- Y N N/A 150'to well uired N NO] z- Z Absorption Field: Total length ft. _ Length of each trench 2ff Depth of trenches -t-z- ft. Size of Stone See Pits: Number k �Y Size: Stone Size: Piping Size Type. Building to tank 4& Tank to Distribution Box Distribution Box to Field Pit Opening Sealed: End Cap N In Outlet Pipes&Baffles Y Manholes 12"or less below grade Y [provide extension collar if Yes Y N Location Separations ' Foundation to tank ft. Foundation to absorption ft. Separation Pits ft. -''"~ � L '' 2-- 2 C Conforms as r Plot Plan N Engineer Report and As-Built Y N v ETU Maintenance Contract _Y N provided " i Location of System o Property:t!!Front Reard Right Side Middle Front Middle Rear Wgm Use proved VO10\Building rtial Approved and needs to be re-inspected, please call the Building&Codes Office approved L:\Pam W Codes Forms\Inspectlon Forms\Septic Irapection Report_03 2910.doc 2009 'served, or bi: As houses, wells, Al ument. I also i d the distances a-_ ;u c jaw GIGNATO E l) TE (Swerma-vi � r Iyept of Com ity I ry OV Town of ► snrY ?42 Bay Road bury,NY 12804 Dale dived: '= 1�.�►1V1E: ���. ATILT: 4", k:FfiW Survey plot pis A Tho.Afte final; a been l by the IZ >~eview the has been: mown, zoning A�s tor, L.\SU4 t ogway\Build hg.Codts k e ayloit $\Finsi swvq Zortittg n atra--doe = N o n Zpole a a %9 W E w a I v a a house NOTES I lands now or formerly of 1. UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY Christopher dt Sherry Bomoby I MAP BEARING A LICENSED LAND SURVEYOR'S SEAL IS A VIOLATION OF SECTION 7209, SUBDIVISION 2, OF THE NEW YORK STATE EDUCATION LAW. (2) underground gas lines 2't WIDE EASEMENT , 2. ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY (SEE DEED REFERENCE 3) MARKED WITH AN ORIGINAL OF THE LAND SURVEYOR'S lands now or formerly of EE NOTE 5 EMBOSSED SEAL SHALL BE CONSIDERED TO BE VALID � Kenneth G. dt Marie C. Pfeiffer TRUE COPIES. iron pipe found S 3. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OF TITLE OR TITLE REPORT AND IS, THEREFORRESTRICTIONS MOF RECORD OR ANY STATEBJECT TO ANY EASEMENTS'ENT OF FACTCOVENANTSS SUCH SUCH DOCUMENTS WOULD DISCLOSE. \ '-*w pin found / 4. THIS SURVEY WAS COMPLETED DURING WINTER CONDITIONS. SOME FEATURES MAY EXIST THAT WERE lands now or formerly of OBSCURED BY ICE AND SNOW AND, AS A RESULT, MAY Glen R. Batchelder 41P NOT BE SHOWN ON THIS MAP. lands now or forme of o, �, Ralph do Carol 5. UNDERGROUND GAS UNES SHOWN ON THIS MAP ARE * o I BASED ON SURFACE MARKINGS PROVIDED BY THE OWNER AND NOT ON DIRECT LOCATION OF THE GAS UNES. y+ Af - +P R- 39.27' L— 25.00' 1. MATTHEW BALL TO MATTHEW BAIL AND SAMMANTHA BALL DATED 23 DECEMBER 2008 AND RECORDED IN THE lands now or formerly of S69 i gas porch ' N WARREN COUNTY CLERK'S OFFICE IN UBER 3698 OF \\ S+ Joseph Sacco, Jr. Brie gas meter DEEDS AT PAGE 89. \ S1 iron pipe found ' ' electric meter \ \\ ?0, gas AC unit chimney 2. TOWN OF QUEENSBURY TO MATTHEW E. BALL AND REC AND ORDED INMANTHA S E WARREN COUNTY CLERK'S OFFICE IN F porch house \ \ / 94.5' Ilf UBER 3698 OF DEEDS AT PAGE 85. \ `S00 3. AN EASEMENT FROM RALPH L BRAYTON TO MATTHEW paved drive \� J 3 BALL AND SAMMANTHA BALL DATED 17 NOVEMBER 2009 \ concrete ' so AND RECORDED IN THE WARREN COUNTY CLERK'S OFFICE \ iron pipe Mound IN UBER 3907 OF DEEDS AT PAGE 278. MAP REFERENCES lands now or formerly of / 1. MAP SHOWING PROPOSED BOUNDARY UNE ADJUSTMENT Robert E. do Alice V. Phila shed , ON LANDS OF MATTHEW E. BALL DATED 11 MAY 2008 iron pipe found \ LAST REVISED 13 MARCH 2009 PREPARED BY DAVID F. transformer 2.346f acres I lands now or formerly of BARRASS, LAND SURVEYOR. Tro Tom Development Inc. 2. MAP OF A PROPOSED SUBDIVISION TO BE KNOWN AS � � SHERMAN ACRES SECTION 11 DATED JANUARY 30, 1990 oi,� LAST REVISED MAY 29, 1990 PREPARED BY COULTER do lands now or formerly of ,6 McCORMACK LAND SURVEYORS. John A. Guyette I ryy TAX MAP REFERENCE iron pipe found TOWN OF QUEENSBURY: 308.06-1-16.1 \ other lands of \ I Matthew E. do Sommantha Ball O iron pipe found MAP OF HOUSE LOCATION SCALE BY DAVID F. BARRASS ON LANDS OF �o sv� o' 50' 100, 150' - LAND SURVEYOR MATTHEW E. & SAMMANTHA BALL 7/27/10 iron pipe found DAVID F. BARRASS 5 MAPLE STREET MWN OF QUEENSBURY, WARREN COUNTY 7 28 10 L.S. # 49363 CORINTH, NEW YORK NEW PORK 05-444 �6 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 i G Arrive: am/pm Depart: -2m/prn Date Inspection request received:�`� Inspector's Initials: -fib NAME: Gam^ �5-- PERMIT#: LOCATION: (,t DATE: O f O TYPE OF STRUCTURE: r _ Comments: _Yps N N/A 4" Building Number Address visible from road f �� Chimney,Height/"B"Vent/Direct Vent Location Fresh Air Intake oe —� 3 inch Plumbing Vent through roof minimum 6 inches rf Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risen Guards at stairs decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brad /Handicapped Ram Com liant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate vv�-e.e Gas Valve shut-off exposed/re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety alging Interior Smoke De ors/Carbon Monoxid etectors �= Every level: Every Bedrk/m: Outside every bedroo area: Inter Connected: Battery backu O',rgk.), Attic access 30 inches x 22 inches x 30 inches(height)in accessible area C e���y� , 6f.' rCAI Crawl Spaces 18 inch x 24 inch access, 1 .ft:150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emeraency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'IV Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closerDuct work Sealed properly Gas L s in Sealed or Glass Enclosure Final Electrical Final Surve Plot Plan Arc Fault,Breaker in Bedrooms Flex Gas Pie Bonding Z'� As BuiWSopfic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,rif required 1 Oka o to issue C/C or C 10 Temporary Permanent/Peanent LABuilding&Codes Forms\Building&Codes\Inspection FormsWesidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26108 Queensbury Building & Code Enforcement - Residential n pectiion Office No. (518)761-8256 Arrive: r, a T�l'J am! Date Inspection request received. Inspector's Initials: 0� NAME: PER #: v LOCATION: DAT TYPE OF STRUCTURE: Comments: N 4" Building Number Address visible from road Chimney Height/'B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks atios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall as Interior/F..xterlor Railings 34 inches to 38 inches Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet VA 6 inch clearance to sill plate \ Gas Valve shut-off exposed/regulator 18 inches above grade �.] �► � Interior privacI trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety lazi /Window in stairwells salf-e-ty glazingJ Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 Inches i ht in acoessible area Crawl Spaces 18 inch x 24 inch access, 1 N.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification c Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade �d Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fi roofi /%hour fire door/door closer Duct work Sealed prop2rly Gas Logo in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if r uired Okay to issue C I C or C 10 Temporary I Permanent LABuilding&Codes FormstBuilding&Codes\lnspec8on FkxmsWesidential Final Inspection Fonrr_reviseck_100405.doc;Revised January 7,2008;Revised SM08 Town of Queensbury Fire Marshal 742 114 Road Queensbury,NY 12804 761-8205/761-8206 fax 7454437 Factory Built Gas Fireplace/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# ©�` U Schedule Inspection U Time _am pm anytime Inspector Name V5 Address ��( 11� Rough In Final Appliance Man facturer � ��S�`L Model# V mil. Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles(all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent Chimney Termination Chimney height must be 3 feet above roof ` n penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel d 1C Height above f/p opening Witness Operation Tank Placement(if LP) White—Baiidins Depk YeHow r Pink—Fire Marshal Town of Queensber Fire Marshal 742 0011oad Queensbury,NY 12804 761-8205/761-8206 fax 7454437 Factory Built Gas Fireplace/Stove Inspection Resort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specificafiods contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's //�� instructions or specifications is allowed. Permit# ®`'t d Schedule Inspections !U Time_eftpm anytime Inspector i'y`1V10 Named`� Address `c;x- Rough In Final Appliance Mann cturer �jAAZ Model# a Direct Vent Factory Built Chimney Flue Size G Double Wail Triple Wall Insulated Yes No NIA Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase �o Wall Penetration I/ Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof �l penetration;2 feet above any combustible t ; l/ construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel c .�.' J, �� �� Height above Vp opening Witness Operation Tank Placement(if LP) White—BuIdhM Dept Yellow r p Pink—Fire Marshal Rough Plumbing / lrsulation In ection sport Office No. (518) 761-8256 Date In ion r e Queensbury Building &Code Enforcement Arrive: '97p art: 10a 742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: PE IT #: LOCATION: INSPECT ON: 12-, O TYPE OF STRUCTURE: Y N N/A Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 1 minutes Pressure Test ' Water Supply Piping 50 P.S.I fo 15 minutes Insulation/R idential Check/Commercial Check filar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water.Piping Insulations If required unheated spaces Combustion Air Supply for Furnace Duct work sealed propedy/No duct tape 7T71 COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Re 'c) Office No. (518)761-8256 Date inspection Queensbury Building&Code Enforcement Arrive: o a 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. L�o NAME: PERMIT#: LOCATION: INSPECT ON: E OF STRUCTURE: Y N NIA COMMENTS: Poo Attic Access 2T x W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Ja do Posts/Main Beams Exterior sheeting nailed properly 12"O.C. . Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Dedc Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D naAs each etas Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center water shield 24 inches from wall ire separation 1, 2, 3 hour re wal , 3, r IMAM Pens algid 16 inch insulation in Cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilinghyall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade L:%Bui ft&Codes Forms-OLDaAdmq&CodssVnspec m Fomalfren ing Fvodogft inspection ReporLdoc Revised JWK*ry 7,2008 Rough Plumbing 1 Insulation Inspec ' n Report Office No. (518) 761-8256 Date Inspection r u s ived: _ Queensbury Building &Code Enforcement Arrive: Pepart: ..LD`�- a m 742 Bay Road, Queensbury, NY 12804 Inspector's In NAME: (3 A U PER I #: Nq— Uyn LOCATION: Z q L L _D INSP T ON: tZ--7—Nq, TYPE OF STRUCTURE: Z Rough Plumbing /Nail Plates Y N N/A Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test ater Supply Piping Head 50 P.S. 15 minutes idential Check/Commercial Check T ek or Similar Exterior Sealant pEF �L�E� Pr r Vent, Attic Vent �►��t ATtol� ; Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed progerly/No duct tape COMMENTS: p EV-1 P i'-�'C-t Eb t ►� Rough Plumbing insulation Report.revised Nov 17 2003, revised Febn,ary 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ st e ' ed: Queensbury Building Code Enforcement Arrive: a m rt: awf—pr�91 742 Bay Road, Queensbury, NY 12804 Inspector's Initials NAME: i PE IT#: ' — LOCATION: , r _i � i � RED INS ECT ON: 1�--�{ —L TYPE OF STRUCTURE: Rough Plumbing /Nail Plates Y N N/A Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test, Drain/Vent Y c��.. Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.{ for 15 minutes �-.--, Insulation/Residential Check/Commercial Check � �"' Tyvek or Similar Exterior Sealant \ Proper Vent, Attic Vent Door/Window Sealed No Insulatio 1 V Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape L ~ COMMENTS: Y.- Rough Plumbing insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection Queensbury Building&Code Enfor�nt Arrive: a part: a 742 Bay Road, Queensbury, NY 12804 Inspector's Initial : NAME: RP41 '�° PERMIT* 0 . -- �0 LOCATION: tJ' INSPECT ON: TYPE OF STRUCTURE: 2L 10 Y 00,N/A COMMENTS: Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Dedc Bracing Headroom 6 ft. 8 in. No 1 es//Bean Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each we t rL ii �t� L ng sq. fl Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from.wall ' separation 1, 2, 3 hour re 4 hour Penetration sealed 16 inch insulation in cavity min. , ( *^ Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Windows Habitable Space I Bedrooms 24 in. (H) N 1 Ak-.\ R� ) ;0 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Budit&Codes Forms-OLDOAdirg&CodesHnspedion FwmTfwrft F' s' doPPkV InePectia►Repoitdoc Reviled January 7,2008 Rough Plumbing / Insulation I pection Report Office No. (518) 761-8256 Date Inspection reque ce' - Queensbury Building &Code Enforcement Arrive: am! rt: 742 Bay Road, Glueensbury, NY 12804 Ins is Initials, c-� NAME: PERI+�fT #: or-6 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes insulation/Residential Check/Commercial Check or 'lar Exterior Sealant --� ` roper Vent, 'c Vent {� Sealed No Insulation Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS. Rough Plumbing Insulation ReporLrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 I0- /z T� s Rough Plumbing / InSulation in action Report Office No. (518) 761-8256 date Inspectioirp§;wst re iv Queensbury Building & Code Enforcement Arrive: 1 Z--�742 Bay Road, Queensbury, NY 12804 Inspector's Init NAME: PERMIT #: LOCATION: r INSPECT ON: TYPE OF STRUCTURE: Y N NIA �Z C Rough Plumbin Nail Plates ?r � . ,,,—Plum /Vents in Place 7w - 70(r's 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum 'ram Cleanout eve 100 feet/change of direction ®� yvJr UJ Pressure Test 7 Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.i for 15 minutes Insulation/Residential Check/Commercial Check L- Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape cc)tAv)oE�� a�� Pu�L L�0t') COMMENTS: '; N- tAk �6 k v � . Z -12 Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Re Office No. (518)761-8256 Date I Queensbury Building&Code Enforcement Arrive: a� 742 Bay Road, Queensbury, NY 12MM Inspector's initial -- NAME: BOO . PERMIT LOCATION: C v INSPECT ON: TYPE £TRUCTURE: z Y N A COMMENTS: txess 22"x 30" minimum Jadc Studs/Headers Bracing I Bridging �� Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwes 36 in. or more Exterior Dedc Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Noes Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wail 1, 2, 3 hour 12, ur sealed ' 16 inch insulation in cavity min. Garage Fire Separation House side's inch or 518 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf alcove/below grade 5.0 sf grade LASuNding&Codes Fortns-0LD\&fth g&CodesUnspection Foam'Fratning Firedopping Inspection Report.doc Revised January 7,2008 D /Z- /V0 Rough Plumbing / Insulation Inspe ion Report Office No. (518) 761-8256 Date Inspection st ----�- �,,, Queensbury Building 8�Code Enforcement Arrive: a m art: 742 Bay Road, Queensbury, NY 12804 Inspector's Initia s. NAME: J '� P R IT : LOCATION: ,-- IN P CT ON: TY QF STRUCTURE: PIZ. Y I N NIA �F6'dle-- um in ent nts in Place 1 '/Z in minimum Drain Size q�j Washing Machine Drain 2 inch minimum , f Cieanout every 100 feet/chan a of directiontP� Pressure Test r Drain/Vent `�a Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Pro r Vent, Attic Vent Door/Window Sealed! No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape VIE COMMENTS: c�� L► ►� GilIJI T Rom. to c OLN) (A► F �T\Rz Rr R LLED F6R Pam"PwM Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Fire ping Inspec i F�eport Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: f NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y A N N/A COMMENTS: ss 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft. or less on center ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (V1f7 5.7 sf above/below grade 5.0 sf grade LABuiiding&Codes Forrns-01.D0ildi%&Codesdnspection Forms Tarring Fling Uispedion Report.doc Revised January 7,2006 Framing / Firestopping Inspection Report Ins Office No. (518)761-8256 Date I Queensbury Building&Code Enforcement Arrive: a a 742 Bay Road, Queensbury, NY 12804 Inspector's In' ' NAME: � RMIT#: 0 �'"a Lja LOCATION: _ T 771— 7f NSPECT ON: G� TYPE OF STRUCTURE: Y N WA COMMENTS: Framing -.-- Attic Access 22'x W minimum Jadc Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nalled properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each skis Draft stopping 1,000 sq. ft. floor trusses Pnchor Bolts 6 ft. or less on center Ace and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in mvity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuNding&Codes Forms-OLMSuNding&CodeeVrapedbn F0MWTra n V Fedoppg Inspection Repoit.doc Revised January 7,20M Foundation Inspection Report ' Office No.(518)761-8256 Date Inspection t r v Queensbury Building&Code Enforcement Arrive: part: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini NAME: PERMIT LOCATION: Ai INSPECT ON: TYPE OF STRUCTURE: Con�menb Y N NA Footings Qo onoiithic Slab Reinforcement in Place , �L�Oz The contractor is responsible for � (� providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Form$\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing 1 Firestopping Inspection R rt Office No. (518)761-8256 Date Inspection st re i Queensbury Building&Code Enforcement Arrive: pa 742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: RMIT#: y LOCATION: INSPECT ON: . TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: Attic Access 2T x 30' minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D naus each side Draft stopping 1,000 sq. ft. flow trusses . or less on center Ice and water sh' d 24 inches from wall 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side r4 inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade L:1Buklft&Codes Fom*-0LDrBukkv&CodesV mWection FwmslFmnft Fnewpp ft Inspection ReporLdoc Revised Jenuary 7,20M Foundation Inspection Report Office No.(518)761-8256 Date Inspection luest received: Queensbury Building&Code Enforcement Arrive: �5 am/pr Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 lw ctor's Initials. NAME: �/�I PERMIT#: O ` _ d LOCATION: i h, Z INSPECT ON: "n A) jdq TYPE OF STRUCTURE: Coa mLenb Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. 'als for this purpose on site. Fo on ur Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\wilding&Codes\lnspeci ion Forms\Foundatlon Inspecctlon Report.coc Last printed 12/20/2005 9:24:00 AM j � 00 C l q Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: (� Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: /I U1 NAME: L L— PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comment Y 01N N/A outings iers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place ��S Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\BuUding&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: - Queensbury Building&Code Enforcement Arrive: am/pm Dep • am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: P #: -0` o LOCATION: SPECT ON: Ad ; TYPE OF STRUCTURE: 9ED L44 VF Co menu _.. n Y N/A iers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Qullding&Codes\Inspection Forms\Foundation Inspection ReporLdoc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date 'ogxequest received: Queensbury Building&Code Enforcement Arrive am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspec 's Initial NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF SIR Y N NLA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 ' ove footing mil Poly'fo wet areas under slab Bac vat Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Fors\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Ins 'on reque i G t Queensbury Building&Code Enforcement Arrive:4�_ inInart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: �--t-- RMIT#: 0� _O t V LOCATION: SPECT ON: G TYPE OF STRUCTURE: Comments Y N3 . Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. � F►l,L Foundation/Wallpour ��/ <_v q7 orcement in Place F !gace Foundation Waterproof g` L 00 ' Da light or Sump inches above FoR6g ✓ '' -- wet areas under slabMPI - i PVC/Cast/Copper Foundation Insulation Interior/Exterier R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundatlon Inspection Report-doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building 8t Code Enforcement Arrive: am/pm Depart: 1�1 i j ram/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: A� NAME: c — PERMIT#: 0 LOCATION: INSPECT ON: TYPE OF STRUC Comment Y N N A 44at 36 r —`�/S— Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the co this on site. Foundation/Walll3our Reinforcement �� - Footing Dowels or Keyway in place Foundation Dampproofing A` O Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Buiiding&Codes Forms\Buiiding&Codesunspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date In do �,;� Queensbury Building&Code Enforcement Arrive: �' a Depart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini a s NAME: P T#: C°-CL9C) LOCATION: 5PECT ON: `I=j—�� TYPE OF STRUCTURE-—— l �� Comments Y N N/A Footings � �i Piers Monolithic Slab -� Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this 2Mse on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 2 Z/ Foundation Inspection Report Office No.(518)761-8256 Date Inspection rrt : Queensbury Building&Code Enforcement Arrive: � Depart:742 Bay Rd.,Queensbury,NY 12804 Inspector's InitiaNAME: P LOCATION: INSPECT ON: J— TYPE OF STRUCTURE: Commel a Y N N/A h s f ✓�� { Footings no Monolithic Slab Reinforcement in Place Y The contractor is responsible for providing protection from freezing for-48 hours following the placement \ Cr ' Of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspecdon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM