Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2009-071
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CE RT I F I CAT E OF OCCUPANCY Permit Number. P20090071 Date Issued: Friday, May 15, 2009 . This is to certify that work requested -o'be done as s! o"m 3 Pei_lit Nulnbez r200900 71 has been completed. Location: 1172 STATE ROUTE 9 Tax Map Number. 523400-288-020-0001-020-000-0000 Owner. GREAT ESCAPE THEME PARK LLC Applicant: GREAT ESCAPE THEME PARK LLC This structure maybe occupied as a: Commercial Addition By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090071 Application Number. A20090071 Tax Map No: 523400-288-020-0001-020-000-0000 Permission is hereby granted to: GREAT ESCAPE THEME PARK LLC For property located at: 1172 STATE ROUTE 9 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GREAT ESCAPE THEME PARK L PO BOX 543185 Commercial Addition DALLAS, TX 75354-3185 Commercial Alteration $900,000.00 Total Value $900,000.00 Contractor or Builders Name/ Address Electrical Inspection Agency Plans &Specifications 2009-071 BEER GARDEN - 5892 sq ft commercial alteration & 522 sq ft commercial addition $780.12 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,April 07, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at a To w�of a ns tl�'`� JAury-, ay,April 07, 2009 SIGNED BY `- ' ' r` for the Town of Queensbury. Director of Building&Code Enforcement a , OFFICE USE ONLY + ; TAX MAP NO.- `-` PERMIT NO. ( / / �f ,` / 0 ; FEES: PERMIT ,�iC-` RECREATION ENGINEERING y (If applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OFF A VALID PERMIT FOR CONSTRUCTION. P APPLICANTf1341�1=-BER: } _(� R S��r^ OWNER: ADDRESS: ( ( 1 L S 7 ¢ F ADDRESS: PHONE NOS. 7R 2' c�7e �7v PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: FA (,U LLN— -- PHONE: .L4 SO LOCATION OF PROPERTY: C__K 15 SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR O d dof U) w U y PROJECT O 00 O F J a x_ W O 00 _Li LLd z d 1- 1- OH W Z z ¢ Q v) c"cn OW rW axas SINGLE FAMILY TWO-FAMILY MULTI-FAMILY(NO._� TOWNHOUSE BUSINESS OFFICE RETAIL- l `L)VVll�l�i MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) C 4r 7C OTHER C. %"N3_I'�f C7 C 5-<e /q Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 _f ;IF COMMERCIAL dR INDUSTRIAL—NAME OF BUSINESS:—( (-t-_ C"11 S � e'Cc7 ecO ES Ti1GIATED CONSTRUCTION COST: 1 FUEL TYPE: HEAT TYPE? 1- *HOW MANY FIREPLACE(S) AND/OR WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: en V r`� �J. ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? yj C ARE THERE EASEMENTS ON PROPERTY? `Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read d agre to the above. Sig ned ned "(� Director of Building & Codes: 761-8256 (for questions CQUESTIONS? CALL 761-8266 OR EMAIL regarding Building Permits, construction codes or septiccodes(ftueensburv.net systems) OUR WEBSITE FOR MORE INFORMATION Zoning Administrator: 761-8218 (for questions regarding www•Queensburv.net required permits, the permit process, application requirements or to schedule an appointment) _____________ This application /proposed action described Permission is hereby granted to the above herein is found to be in accordance with the Applicant to ere lor alter the building described zoning Laws of the Town of Queensbury. ; herein in acco a with said Application: ZONING APPROVAL DATE Oo BUII I G &CODE PPROVAL DNrq t Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection que eiv Queensbury Building&Code Enforcement Arrive: = a m Depart: am/pm 742 Bay Road Queensbury,,ANY 12804 Inspector's Initials NAME: / C� PERMIT#: LOCATION: Z 7 DATE: - COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in. w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(])/Canopy or Equiv. _ Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %2 doors > 10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection reque re iv : Queensbury Building& Code Enforcement Arrive: LA'- Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT / C9 IZ--i LOCATION: �f E2 E DATE: — COMMENTS: Y N NA -Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks _ Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.-38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site 0 Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 s . ft. 3/a Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft.Wood Frame ]_ Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides Surface 20'wide Okay To Issue jLrg�'—or Permanent C/O Okay To Issue L:\Building&Codes Forms\Building& CoZft4nspection Forms\Commercial Final Inspection Report.doc Inspection for Permit to Occupy dire Marshals OMce Request Rec'd Permit No. 400 ( -7 l Town of Queensbury 1 742 Bay Road Queensbury,NY 12804 Scheduled Inspection Date: Time: Phone: (518)761-8206 Business Name: Fax: (518) 745-4437 Location: �Sr �L T of Inspoction N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width -Secondary Aisle Width EXIT SIGNAGE Sign-normal Sign-battesigns �I EVAC signs in rooms �� 1 TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hun Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System FDC Fire Suppression-kitchen Fire Suppression-Gas Islan rr�IN" 106 Gt Generator may I Hood Installation Elevator E Interior Finishes j Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed/Labeled �`1ry>-�- --j Combustible Waste Vehicle Impact Protection Knox Box F.D.Si na e-Utility Rooms No Smoking Signs Maximum Occupancy Sign Emergency Evacuation Plan pproved (If no other approvals apply,the B&C Office will issue the Ce icate of ccupancy) ❑ Denied / call for Recheck Inspected By: L:\FireMarshal\New Folder\permitto occupyform.doc Inspection for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. -7� Town of Queensbury 742 Bay Road Qu � 21� Queensbury,NY 12804 Scheduled Inspection Date: s f/O Time: Phone: (518)761-8206 Business Name: 091P/oe— 1::P405`t' } > � Fax: (518) 745-4437 Location: if 72- Typo of kupecHon N/A Yes No EXITS: Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Se-co-nda- ry Aisle Width EXIT SIGNAGE Sign-normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hun Inspection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System FDC Fire Suppression—kitchen Fire Suppression—Gas Islan Generator Hood Installation ^� Elevatork + 2� 5 Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed/Labeled Combustible Waste Vehicle Impact Protection Knox Box F.D.Si na e-Utility Rooms No Smoking Signs _ Maximum an Sin Emergency Evacuation Plan ❑ Approved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) Denied I call for Recheck lnspec By: L:\FireMarshal\New Folder\permitto occupyform.doc tJ i 1 .t Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection reque e7* d: Queensbury Building& Code Enforcement Arrive: Depart: am/� 742 Bay Road,Queensbury,NY 12804 Inspector's Initial NAME: �� A D PERMIT#: Q — LOCATION: � DATE: `5 COMMENTS: Y1 N NA Chimney/"B"Vent/Direct Vent Location _ Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks _ Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in. w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed 8" Above Grade Floor Bathroom Watertight&Qfter Floors Oka Relief Valve,Heat Trap/Water Temp. 11 egre aximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 s .ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors bl•.� Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Acces des 20' /Driveable Surface 20'wide Okay To Issu Tem ermanent C/O Oka To Issue L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc 16) CC8 ' A Commercial Final Inspection Re ort Office No.: (518) 761-8256 Date Inspection requ t e iv d: Queensbury Building&Code Enforcement Arrive: ^r am/ Depart: Wam/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: — / NAME: PERMIT#: LOCATION: DATE: COMMENTS: Chimney/ B Vent/Direct Vent Location Y N NA Plumbing Vent Through Roof 6"/Roof Complete �- �E�i7 F i��(w Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.-38 in. /Step Risers 7"/Treads 11" M� �� �, `- r Vestibules For Exit doors>3000 sq. ft. All Doors 36 in. w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 w)x 44"(1)/Canopy or Equiv. ALt (W-- 5 t U" Gas Valve Shut-off Exposed&Regulator 18" Above Grade b (- Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum LAt7Ek l i- Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion `71s�j i et"k 6 t U,6'Z t*aisc� Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area C_-1-o�� ell Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %2 doors > 10%> 1000 s . ft. - 6RQ�7\ 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors ,✓ Ceiling Fire Stopping,3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed OG Handicapped Bathroom Grab Bars/Sinks/Toilets Handica ed Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides] Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,ff req. As-built Septic System La out Required or On File Building Number or Tenant Address on Building or Driveway ' Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r e iv Queensbury Building &Code Enforcement Arrive: i a a a 742 Bay Road, Queensbury, NY 12804 Inspector' In' s NAME: ! ti ti �PERMI #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: . i ti Y N NIA Plates n en ts in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test D ' /V ad AM .S. . above highest connection for 15 minutes ure Test Water Supply Piping r P. 15 minutes I on/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: z_ Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7.2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ cam' ed: _ Queensbury Building &Code Enforcement Arrive: am m part: a 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: &&?, g�)EL P T : --0 7 I LOCATION: IN ECT ON: ►-} ZZ$-C�ei TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout eve 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: R6 tAEE7-1OG UJ5 Qt�Ut3 F?o -A OV- F&R )V\0 �AO LL` G�A v-� F Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Re rt Office No. (518)761-8256 Date Inspection ed: Queensbury Building &Code Enforcement Arrive, ' part: a m 742 Bay Road, Queensbury, NY 12804 Inspector's In' ' I NAME: Or=F-P, CR — PERMIT# LOCATION: INSPECT ON: '-4 TY OF STRUCTURE: Y N NIA COMMENTS: Framing Pt Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on centerN- Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-01-MBuilding&CodesNinspec Lion FomslFrarning Firestopping Inspection Report.doc Revised January 7,2008 Rough Plumbing / Insulation Inspection epod Office No. (518) 761-8256 Date Inspection reque iv Queensbury Building &Code Enforcement Arrive:q�_am1 art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: . FERMI #: a LOCATION: ti INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing / Nail Plates Plumbing Vent I Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above h' hest connection for 15 minutes Pressure Test Water Supply Piping e 50 .S.l fo 15 minutes Insulation/ esidential Check/Commercial Check sz? rmilar Exterior Sealant Proper Vent, Attic VentQ Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces / Combustion Air Su for Furnace � Duct work sealed properly/No duct toe COMMENT Rough Plumbing insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing 1 Insulation Inspection Report Office No. (518) 761-8256 Date Inspection regye r ived. Queensbury Building 8� Code Enforcement Arrive: a art: r Q a 742 Bay Road, Queensbury, NY 12804 Inspector's Initials f 4 NAME: PER 'T #: �_l LOCATION: �r,R t-Ej INSP CT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent -t. � - Door/Window Sealed No Insulation _ Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properlyi No duct tape COMMENTS: i Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspec n Report Office No. (518) 761-8256 Date Inspection r ue t e ived: Queensbury Building & Code Enforcement Arrive: a art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's I a v NAME: �--� `'Irc �-�' ERMI LOCATION:il INSPE ON: TYPE OF STRUCTURE: Y NIA Rough Plumbin Nail Plates iumbing Ve Vents in Place w'1 1 ' m minimum Drain Size PC75 Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 0 r 15 minutes Vk Residential Check/Commercial Check Imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS; Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ r ived: Queensbury Building & Code Enforcement Arrive: \ Hu a pm' rt: �a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: PERMIT PERMIT#: LOCATION: INSPECT ON: -Z�)-p`� TYPE OF STRUCTURE: N N/A Rough Pkimbmg/Nail Plates Plumbing Vent 1 Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test in /Vent Air .Sr 10 ft. above highest connecfion for 15 minutes ressure Test Water Supply Piping r/Head 50 P.S.I for 15 minutes Insulation esidential Check/Commercial CheckAL� � of TWokV-Sirnilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Foundation Inspection Report 11�00 . Office No.(518)761-8256 Date Infection St _ Queensbury Building&Code Enforcement Arrive: 4 = part: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini ' s: NAME: PERMIT#: LOCATION: (n ^—`- E INSPECT ON: q_�3 TYPE OF STRUCTURE: E Comments Y N N/A Footings iers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Rough Plumbing / Insulation ection Re ort, Office No. (518) 761-8256 Date Inspection r s ived. Queensbury Building & Code Enforcement Arrive: a m 742 Bay Road, Queensbury, NY 12804 Inspector's In' NAME: PE IT �C��l LOCATION: a-S INSPECT ON: 0 x, PE OF STRUCTURE: —� NIA 1 %2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Test titer Supply Piping � �, �� '�50'P.S.I for 5 minutes ntial Check/Commercial Check e or Similar Exterior Sealant Pro r Vent, Attic Vent IVA Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation p` �9 If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection ed: Queensbury Building&Code Enforcement Arrive: IU part: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: T#: 09 LOCATION: `7,r SPECT ON: TYPE OF STRUCTURE: Commenb Y N N/A Footings Piers Monolithic lab - � m Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 roil poll for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspecdon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date In pectiM.requ Queensbury Building & Code Enforcement Arrive:j��a m rt: 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: `� 1 PER #: LOCATION: C,� ,i � � INSP CT ON: TYPE OF STRUCTURE: Y A N N/A Rough Plumbin9jNail Plates Plumb' t/Vents in Place ng 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain ����,�..- ►�\..- Air gads-- 5 P. . : r 10 ft. above h' hest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Su for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection reque _ Queensbury Building&Code Enforcement Arrive: ' `OD Depart: p 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi • 1 � NAME: PERMIT#: LOCATION: _ — �� INSPECT ON: 4-11 TYPE OF STRUCTURE: Comments ' Y N N/A Footings Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: �. 12 inch width 6 inches above footing7� 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PV -Copper Foundation Insulation Interior/Ext for R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Ala i - 4214 c l i w o = o mf n _ 4 rc r6QIL0 wow �oo��z o o e 03 I` oz Y l Q � rr 'v o W v 1 t - ( � I �." C w� l a.J k rr _ t rw I \ i a Co rr IL in VI ui Ua' ,� M �tV s� �' r��iA n lJ 1 �" { `,,n I i� E' "lFl If uir �Pw ?� �t � s �LU Wco W3 OVP `�c$' r Q� f4;,v';1 FS ttXgyerrj 4,. �~ acn ui 12 _ UJ c yt3N ono - W W _ _ - _ _ 5 t5 ++P'Oa003a t naa 0LL060 4t'bS01p sail,savnos pa003H I h3a OZLOfiD tl'9S01p suulssiwgns S:1VN 1533 3NIdlV bl'650-10 sanuah a oas3 IDalp b90-10 slDa.D.d IODZ a Das3 IDa:p sal!d 11a191d WOZ al-00:33111 ao a s3ow �' w s � U,w Y h w 4 o - - g rro '� Li_ " v W Cn ascar35} bA^ d NW z m rc� -iz� x o $ 5 t; 12 wi w w O W LLLC w �z ? �6w �a ~ J w z zw �Q x owo °tw ogoo°z a aF HE- M adz z 8 wo n" u Paz o " z i o�J w N S Z. w oho o o opt a 3sz o $� z sa - oQQQ°Q LIn j �a o oN u o Nzo ,.5 z` za a z� aozj w � o a e Owa'�- < € z, z x W w z 3 a�o� a o y Sj 1 „ Q q q w m s N oo q AC G <o ie s m ul - / z � 3 1�O� a � �J�y�yy�,T�zz O 29 w s'N NFU og x 4. 1om4w o _ gswgg� m �•I W >=W r m y...6 yiaon 3nai —��� �.��,aanevc otl3Noury C C2 MG'060038 t n3a OZZ060>L KOt0 ss!9 sas—OU0D3a t n H OZLO60 rot'65DtD s-- s snVH 153J 3Nid'IV YI'450-10 sanuan a—3 I1119 t9O-IO slaa,o,d 100Z a—3 Ioa/ sai!3 Iaa o/d IODl al!3olop 33313 N Qo o t6 zw M, gZ M. ZD IL Z 7,W fr (D ti zw Cc r,7 l<<Q Y CO g T 3, r4 E R ;3 IN E." IL LU tj 21 P9 Di 00 "11,40 A1. U—o-1 I A3d WJQ Q 11 1533 W 11 1l ........... .....a oas3 4-9\.q NO 4� oW LL 12 oz 95 0 o zamoomsW X� o 2a �Q k 'boo - � O w _ wizw o <ffia A�� z`o a - a zd�? a� pamo S o 5c_ bb w Z Won¢m a �� q -i� a -- FU g 50 -,5 o� oz o cja w s o aGo zia po�_, _ &p 2 � O z m vwi w3oa 5or�oo� w 0 2w�w �= w �a (��° -J w OO �//'s oP i 0 m - zw '" w <� _�zw - n��o� og �o� Gix - a o paa �wt,a 33 ww = p� xw"" a 0Vtia3rcow o- ��a �weNEd uaxwS rc�rz_�a� _ 9 �gabp -a`x'rc ao?mamo g Ud°hw"eo�4 ��w-z�owNFoamo " oz 0o 0anm Fzmxooz"m o_On Ng ovi3Uz U atRoo o ¢zIt z o a � _Uz w Nonz 3 maU mqN 4 >g ¢zv ~K 3 ' lo o oQ���J FiRE�, dr Wg� wiz o52 Y ao a� �2o a a e•z rF a < �z 3`" Qzo' , .T �1u� vz o Ma 5 i,a'g - dN - was ws w w> _ So ozN"N z tl Tod OV�a N mmn v vxo aSYi�3 n r_ 9 - 3o rc nw EN OQ� q < R \ �` - w il 12 o w x�M O / \ / r L a V i v r — -- 1 1 I 1 Uw �oaG p M p o 3ul avx E-- N P N o b m r rc V d; ^D'Oti003tl I A3i OU06D 1,'b Ot0 sal!;s--OBOD3b I A38 WID60 bl'tS0I0 suo!ss!wgnS 0VH;533 3N!d'IV Yl'bG-ID sa—a oas3 loa.9..O-I,saaaoad t00Z a ws3 loai0 sa!!3 laa,o..IOOZ a!!3o;aO�d311J O o g _ o Q a o F ZZY a o E - w o ° www o - O Z3: 0 N m g5 < U }' ¢ OJ o � a as U Wo o co, z '+3 J .u) bA o F V5�w a w 0 $� O z o° -vy a. o $ sa _ _ O N a�q odQ�Q QF'�rrT E S mo € ' d' A 9 Qom A 1n ` xy s o CF Ip EE U. LL O - o�� - - om r z tts{ / n� � U w Ow i�oo _ 3 Zm8b m m 3b 01 as w� w��_., poaa sv a3no3 i #o o'^ LL o�LL w O g r r o a"m �moNo z a � Z3 o 0 aJ o C E 11 g Cs mP'Oa033a l A3a MOM al'450t0 saW sa 1—MDD3a I A3a 0ZL060 al'>SOIO su s!wgnS STN 1S33 3NIdW 4l'tr50-10 sanuaA ad-3 toaap 450-l0 siaa.old 100Z a oas3)oaip sa�i3 aaa,oad t00Z apdotop:}33}d W LLoi mN " o wFw o ~av=UiwoE '=� y w 0. Ito Z� 2q O 8 00 �m o VI [zl o �� orn zw rc2 �a wi?a�3 ozN zso ¢ziW w v¢~i 1Y w S rna caiN3 =o; ~;a �-� wo o3zz�"� zmv�i wsx�a4� z 4�'i o o WCC ^Y �0 0 m-60�Y •bQc rcOrcr�=in Ywoa�U.+Qo ¢�ma us N W o O N w s ww >_ oa�iOw ooarcz"" wc� gwzo�g o� -&� oizN N (,� ww (Yi o o a w wkW 3� -¢w osa oor x z ZwI}= ao C7 a ?a' - w G`ozawo xaw w4 „ oz �33 a o a!- Fw w ME ts 3 zow z� 3z aoF= m�zam y 3ww�$o - xo oar aN oq V®Q r \` �''t o m �u u�zu` a o �z z �0. -Gw ggp x Gn!� " N.. w m o _mom m`da M aa_ a m a 3�. <`a "'� NZ, was am ti L a O oU i ¢ m= o f H. N W z w r r < zG Q o� z gG ■' � g �GoJ �� N V 0 031JI33dS SV 1H913H 3V101 - EDz as c N z-9 A o� O z 18 10 - -owa O N � V �X<� oo awn �xo ow. i - o lz _� -:N"" Yw " zGz o 0 qs�o z� a oo 2�6 o a m e = w a 5w O _ w o 2 ' z z o � o � z_ H z � w x z n W z ONIOl3iH5 HJN3N1 - r w ' d 6 1,5 �otn 01 � ca E w F- w -W00002d t A3M 0ZL060 41'45010 sa!!l sa,—OJOJ3N l 13tl 0,40.0 bt'4S0t0 su9-!wq^s 50VH 1S33 3NIdlY bt'450-10 sanuaa a oas3)oast 450-t0 slaa,osd tOL a oas3)oas0 sal!3 ls?aid t00t al!3o100 331[J � m b 1112 � pY a o0 0 W¢ 55w? Fj q F a�l o J WNotz yO F' na�� i s z uW_¢at i r � z o a� a o� o F W � o Q c N�o Ip N u « � oR ul Iz zm o s z U boo o= ao 'We °o 3!d i 11 O s i a t- i° a Ana 03013. ! q w F z Y¢w _ G <s :a a- MP'OU003N 1 A3f OZL060 at'>90t0 sal!!saa—0J003J 1 A33 OZL060 trt'65010 san!ss!wgn5 Slltln 153J 3NIdlV§t-t50-10 S—M a oac3 1oa10 t00Z a 13!1110 sa!!3�sa,ad t00Z al!3gig0:3.31i.i �aa w N w s m m` w S. W Cw O �Ns°'m o ao S Z =v w o rc ww uo z q y�Q(�9w Fen O LLLL W oz o.aoo p3 oaf �V zo �z aG m m oW m � w �o aE O N� z zw a a�a ;o a`w Q z #0 iw os Si�oc3�3 o wo aw 3LL oW w N �r�� N oaN z o o�oG >3� Diu N�? zq <u w L a ��o w w°�° A.. $p P, 3� x - mLL o m U psQ so -ms Q p Y Div J i s� ct7 o` Y. Z.a E o zm�. z 510 Uin.oz N - a w ao�2 ."° 0. U 5 z two us o Y _ o Q �� 3 m Q Ci� Q �, H N O Z r� �w c/Y• MP'080338 t A3l MOO 4l'4MG salit sa —� 0y003N t A H OZ4060 trl'45010 suu!ss!wgn5 5!itlFi 733 3N"ly 770-10--A a ws3 MID 190-10 staa.oa3 tpOZ a oss3 loa:0 sal!3 pa Pid tpOZ al3gao0 3.31i3 Pioneer Elevator Inspection Services Checklist for Inspection of Electric Elevators General Notes: (a) See ASME A17.2-2001 for detailed inspection information on each item number. (b) OK=meets requirements: NG=insert number to identify comment on back of this checklist: NA=not applicable. ❑ Routine Inspection and Test Address: Great Escape Six Flags ❑ Periodic Inspection and Test ueens ury, NY 12804 0 Acceptance Inspection and Test JAI :2 Code Edition: ASME A18.1 -2005 ID No: Multi Lift !! Inspected By: Thomas Darnley 0 Passenger Rated Load: 750 Ibs Signature: Date: May 11, 2009 ❑ Freight Class Speed: 8 fpm QEI No: E-282 Certifying Organization: EIWPF OK NG NA OK NG NA ELEVATOR-INSIDE OF CAR 2.15 Static Control ❑ ❑ 0 1.1 Door Reopening Device ❑ ❑ 2.16 Overhead Beam and Fastenings ❑ ❑ 0 1.2 Stop Switches 0 ❑ ❑ 2.17 Drive Machine Brake ❑ ❑ 1.3 Operating Control Devices 0 ❑ ❑ 2.18 Traction Drive Machines ❑ ❑ 0 1.4 Sills and Car Floor 0 ❑ ❑ 2.19 Gears, Bearings, and Flexible Couplings 0 ❑ ❑ 1.5 Car Lighting and Receptacles 0 ❑ ❑ 2.20 Winding Drum Machine and Slack Cable ❑ ❑ 0 1.6 Car Emergency Signal 0 ❑ ❑ Device 1.7 Car Door or Gate 0 ❑ ❑ 1.8 Door Closing Force ❑ ❑ 2.21 Belt-or Chain-Drive Machine ❑ ❑ 1.9 Power Closing of Doors or Gates ❑ ❑ 0 2.22 Motor Generator ❑ ❑ 0 1.1 Power Opening of Doors or Gates ❑ ❑ 0 2.23 Absorption of Regenerated Power ❑ ❑ 0 2.24 AC Drives from a DC Source ❑ ❑ 0 1.11 Car Vision Panels and Glass Car Doors ❑ ❑ 2.25 Traction Sheaves ❑ ❑ 0 1.12 Car Enclosure 0 ❑ ❑ 2.26 Secondary and Deflector Sheaves ❑ ❑ 1.13 Emergency Exit ❑ ❑ 0 2.27 Rope Fastenings ❑ ❑ 0 1.14 Ventilation 0 ❑ ❑ 2.28 Terminal Stopping Devices 0 ❑ ❑ 1.15 Signs and Operating Device Symbols 0 ❑ ❑ 2.29 Car and Counterweight Safeties ❑ ❑ 0 1.16 Rated Load, Platform Area, and Data Plate 0 ❑ ❑ 1.17 Standby Power Operation ❑ ❑ 0 3 ELEVATOR-TOP OF CAR 1.18 Restricted Opening of Car or Hoistway Doors 0 ❑ ❑ 3.1 Top-of-Car Stop Switch ❑ ❑ 0 3.2 Car Top Light and Outlet ❑ ❑ E 1.19 Car Ride 0 ❑ ❑ 3.3 Top-of-Car Operating Device ❑ ❑ 0 3.4 Top-of-Car Clearance and Refuge Space ❑ ❑ 0 2 ELEVATOR-MACHINE ROOM 3.5 Normal Terminal Stopping Devices 2 ❑ ❑ 2.1 Access to Machine Space ❑ ❑ 0 3.6 Final and Emergency Terminal Stopping 0 ❑ ❑ 2.2 Headroom 0 ❑ ❑ Devices 2.3 Lighting and Receptacles 0 ❑ ❑ 3.7 Car Leveling and Anticreep Devices 0 ❑ ❑ 2.4 Machine Space 0 ❑ ❑ 3.8 Top Emergency Exit ❑ ❑ ED 2.5 Housekeeping 0 ❑ ❑ 3.9 Floor and Emergency Identification Numbering 0 ❑ ❑ 2.6 Ventilation El ❑ ❑ 2.7 Fire Extinguisher 0 ❑ ❑ 2.8 Pipes,Wiring,and Ducts 0 ❑ ❑ 3.10 Hoistway Construction 0 ❑ ❑ 2.9 Guarding of Exposed Auxiliary Equipment 0 ❑ ❑ 3.11 Hoistway Smoke Control ❑ ❑ 0 2.10 Numbering of Elevators, Machines,and ❑ ❑ 0 3.12 Pipes,Wiring, and Ducts 0 ❑ ❑ Disconnect Switches 3.13 Windows, Projections, Recesses, and ❑ ❑ Setbacks 2.11 Disconnecting Means and Control 0 ❑ ❑ 3.14 Hoistway Clearances 0 ❑ ❑ 2.12 Controller Wiring, Fuses, Grounding,etc. 0 ❑ ❑ 3.15 Multiple Hoistways ❑ ❑ 0 2.13 Governor, Overspeed Switch, and Seal ❑ ❑ 0 3.16 Traveling Cables and Junction Boxes 0 ❑ ❑ 2.14 Code Data Plate 0 ❑ ❑ Page 1 Pioneer Elevator Inspection Services Checklist for Inspection of Electric Elevators 3.17 Door and Gate Equipment U ❑ ❑ 5 ELEVATOR-PIT 3.18 Car Frame and Stiles 0 ❑ ❑ 5.1 Pit Access, Lighting, Stop Switch, and 0 ❑ E 3.19 Guide Rails, Fastenings, and Equipment 0 ❑ ❑ Condition 3.20 Governor Rope ❑ ❑ 5.2 Bottom Clearance, Runby, and Minimum 0 ❑ E Refuge Space 3.21 Governor Releasing Carrier ❑ ❑ 0 5.3 Final and Emergency Terminal Stopping 0 ❑ E 3.22 Wire Rope Fastening and Hitch Plate ❑ ❑ E) Devices 3.23 Suspension Rope ❑ ❑ E] 5.4 Normal Terminal Stopping Devices 0 ❑ E 3.24 Top Counterweight Clearance ❑ ❑ 0 5.5 Traveling Cables 0 ❑ E 3.25 Car, Overhead, and Deflector Sheaves ❑ ❑ 0 5.6 Governor-Rope Tension Devices E7 ❑ E 3.26 Broken Rope, Chain, or Tape Switch ❑ ❑ 0 5.7 Car Frame and Platform ❑ ❑ E 3.27 Crosshead Data Plate ❑ ❑ 5.8 Car Safeties and Guiding Members-Including ❑ ❑ E 3.28 Counterweight and Counterweight Buffer ❑ ❑ 0 Roped-Hydraulic Elevators installed under 3.29 Counterweight Safeties ❑ ❑ A17.1b- 1989 and later Editions 3.34 Compensating Ropes and Chains ❑ ❑ 0 5.9 Buffers and Emergency Terminal Speed ❑ ❑ E Limiting Devices 4 ELEVATOR-OUTSIDE HOISTWAY 5.10 Compensating Chains, Ropes, and Sheaves El El E 4.1 Car Platform Guard ❑ ❑ 0 4.2 Hoistway Doors 0 ❑ ❑ 4.3 Vision Panels ❑ ❑ 0 6 Elevator-Firefighters'Service 4.4 Hoistway Door Locking Devices 0 ❑ ❑ 6.1 ❑ A17.1 b-1973 through A17.1 b-1980 ❑ ❑ 0 4.5 Access to Hoistway ❑ ❑ 6.2 ❑ A17.1 - 1981 through A17.1 b - 1983 ❑ ❑ El 4.6 Power Closing of Hoistway Doors ❑ ❑ 0 6.3 ❑ A17.1 1984 through A17.1a - 1988 ❑ ❑ 0 4.7 Sequence Operation ❑ ❑ 0 and A17.3 4.8 Hoistway Enclosure � ❑ ❑ ❑ El 0 6.4 ❑ A17.1b 1989 through A17.1d -2000 4.9 Elevator Parking Devices 4.10 Emergency Doors Blind Hoistway ❑ ❑ 0 4.11 Separate Counterweight Hoistway ❑ ❑ 0 4.12 Standby Power Selection Switch ❑ ❑ 0 This Checklist,At 34C1,may be obtained from the ASME Order Dept.,22 Law Drive,Box 2300,FaiMeld,NJ 07007-2300(12/01) Comments: i need a full load test During first maintenance exam. Send a copy of the test result to Pioneer's office. f- No Text Below this Line > > > Page 2 N4kIFf [ IGT{QJ(! .IN,.��f�'r(3[�`1SY&�f�+J� _ . _ ...,�.. .:..,4 � ._ �,:' _ � � ,, ,. _. •.Ftl�� �Ft�,T 4 p ` t .�FY E yPSY *4r F 0,'T 4NWP�,tk ,�11t p r r�r�NP, Y FJ F 14 ; May 12, 2009 Town of Queensbury Bay Road Queensbury, N.Y. 12804 Attn. Mike Palmer, Gary Stillman Re. Alpine Festival Haus To whom it may concern, As of May 5th 2009 the Elevator installed in the Alpine Festival Haus Building at the Great Escape has been tied in to the fire alarm system for the purpose of turning off the power to the unit in the event of an activation of the heat detector on the ceiling mounted within 2 feet of the sprinkler head. If there are any questions pertaining to this work please feel free to contact me at your earliest convenience. Regards Ernie Sacco Page 1 FIRE CONTROL SYSTEMS INC. 104 REYNOLDS RD.,FORT EDWARD, NY 12828 P (518) 747-2567 FAX 747-2518 www.firecontrolsystemsinc.com email: info@f s88.com 5/8/2009 Mr. Michael Palmer Fire Marshall Town of Queensbury 742 Bay Rd. Queensbury, NY 12804 Re: Beer Garden _ Akmc-- + � Great Escape Queensbury, NY 12804 Dear Michael: The fire sprinkler system for the above building has been completed and is on and operational. To the best of my knowledge, the system conforms to the NFPA 13 Standard. If you require anything further please give me a call. Sincerely, chard E. Boucher Sec-Treasurer TOWN OF QUEENSBURY Date ELEVATOR WORKSHEET Inspector ELEVATOR TYPE' Electric Hydraulic Location MAKE: ODEL: NY?D}31 is YEAR INSTALLED MACHINE ROOM LOCATION: LAST INSPECTION DATE: SPRINKLER SYSTEM: Yes No 13 DETECTION PASS FAIL NR PASS FAIL NR Machine Room Heat Hands Free Comm. Pit Heat I Hositway Hatch Top of Shaft Smoke Top of Shaft Heat Insp. Records Posted Machine Room Smoke Maint. Records Avail. Floor 1 F/F Service Keys Floor 2 Hositway Keys Floor 3 Floor 4 PHASE 1 Lower Level Recall (Smoke) Pit Light Pit Sump Recall (Switch) Shunt Trip F/F Emergency Operations PHASE 2 Fire Ext in Machine Room Function Test PROTECTION SYSTEM NEW YORK FIRE & SECURITY INSPECTION REPORT 4 Glens Falls Technical Park Glens Falls, NY 12801-3802 DATEO ORD Ij OR EB Ar (518)798-9551 i/ OR u Fax(518)792-5199 ORDER TAKEN BY PHONE P.O.NO. 0 JOB NAME/NO. A L �-ST JOB LOCATION INSTAL TION ATE LAST INSPECTION INVOIC DATE' JOB PHONE INSPECTION ;� -� �y SYSTEM EQUIPNF MANUFACTURE INFORMATION dr.,,U QQ t 1 SYSTEM INSTALLER - R.O.R. Fixed Heat - SYSTEM AP LIGATION �A j Photoelectric f -1 L` f— f TYPE OF SYSTEM Ion y Duct MAINTENANCE PR9GR3M BY Flame " t CALL LIST UP TO DATE Manual Yes No Cross Zone "`' REMARKS Single Zone s .; Contacts Motions „ " ., Photobeamse `�:;' '`t = `�` " s"a;: n ssa Tr,. Water Flow s ... -Leg,i. Low Airr1ls;.. A.C.Voltage 7.71 Weight A.C.Voltage Sprinkler Tamper ve D.C.with Load • Last Hydro D.C.Voltage D.C:'without Load '• Gauge Pres a D.C.w' ut Load Air Hand ¢ ; ME-IJ-'r}4+,-rr Se Door Release kw g Duct Damper „' N iG� r } Equipment Shutdown yy A.C.Voltage k s D.C.Voltage '; Battery oft " Detection Circuit Audible Circuit "`=. 4- Remote Activation Audible Devices : Visual Devices r F. z Pre.Discharge " Signs As Needed a4r Selector Valves Piping Nozzles '= Tanks j y �z Gauges ' INSPECTOR_ Piston Activator Solenoid SYSTEM FUNCTIONAL " z ,: I hereby acknowledge the satisfactory completion ' �,. `° x �� of the above described work. - Manual Release y cif" „ El SYSTEM NON-FUNCTIONAL Time Delay Remote Station Trans. �'� �z' sry r � ..,�xfi � ,,! ❑ DISCREPANCIES Digital Dialer NOTED ABOVE Voice Dialer s ig IT ) �. �S'nature itle Date Phone Line s;�� ��,, FIRE ALARM SYSTEM CHECKLIST Date: 7 D Name: -4L Location: 6.t,��� WA YES NO Fire alarm system plan and facility layout provided Manual pull stations visible Fire alarm panel room has proper designation on d *' Confirm receipt of alarm at central station(supervise *- Local fire alarm signage posted Zone chart posted Verify strobe function at silence stage Tamper and Flow switches tied into alarm panel-r- Hood suppression tied into alarm panel-*-- Afrix do not reset sticker to panel-educate persone System test;Pull station * Smoke detector-.�c Duct detector HVAC shutdown All required keys secured Inspector Inspection for Permit to Occu pY We Marshcrd's Mce Request Rec'd Permit No._f^/ Town G4 eensbury �✓ QueensWu N 12804 Scheduled Inspection Date: __ 1 Time: Phone: (518)761-8206 Business Name: Fax: (518)745-W7 Location: — TWO of N/A roz No EXITS Exit Access Exit Enclosure COMMENTS Exit Discharge AISLES: _ Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Si -normal l n ( y b Sign-batteryI ) P►, �" n EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: Hun Inspection of extinguisher F �~ FIRE ALARM SYSTEM Fan Shutdown ; Fire Sprinkler System '�c, fire Suppression-kitchen I" ` / C < Fire Suppression-Gas Islan Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed/Labeled Combustible Waste Vehicle Impact Protection Knox Box F.D.Si na e-Utility Rooms No Smoking Signs Maximum Occupancy Sign Emergency Evacuation Plan 0 Approved (If no other approvals apply,the B&C Office will issue the Certificate of Occupancy) a Denied / call for Recheck I Inspected By: L:\RreMarshal\New Folder\permitto occupyform.doc Range Hood systems Report SERVICE COMPANY DATE O RJVE TIME A.M. P.M. _ /�O .il ANNUAL SEMI-ANNUAL I RECHARGE INS AL TION RENOVATION LOCATION OF SYSTEM CYLINDERS �1 UL 300 ES ❑NO M NUFACTURER MODELrrNN,UMBER E DRY CHEMICAL _ L IGf� LENDER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE FUSE LINKS 360'F. FUSE LINKS 450°P. FUSE-LINKS.500°F. OTHER PUSTOMER Name 6NDill� FUEL SHUT-OFF ELECTRIC GAS SIZE , )< /X Address SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE CityQ State ZIP S2_442 MANUFACTURER'S MANUAL REFERENCE Telephone Store No. PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager COOKI G P NCE LOCATIONS: L T R 1. All appliances properly covered w/correct-nozzles _ 20. Replaced fuse links 2. Duct and plenum covered w/correct nozzles 21. Check travel of cable nuts/S-hooks 3. Check positioning of all nozzles. t' ' 22. Piping&conduit securely bracketed 4. System installed in accordance w/MFG UL listings 23. Proper separation between fryers&flame _ 5. Hood/duct penetrations sealed w/weld or UL device "� 24. Proper clearance-flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same ""~' 26. All filters in place 8. Pressure gauge in proper range(If gauged) 27. Fuel shut-off in on position 9. Check cartridge weight(If applicable) 28. Manual&remote set/seals in place 10. Hydrostatic test date (O 29. Replace systems covers _ 11. 6 year maintenance date 30. System operational&seals in place 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link - 32. Clean cylinder&mount 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch - 34. Personnel instructed in manual operation of System 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles l� 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service&Certification tag on system 19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW t� COMMENTS: NON Aru Go Llid t- . tf�� On this date, this range hood fire suppression system was inspected and operationally tested in accordance with the fire suppressio s stem quirements of NFPA17 or 17A, 9 d the manufacturer's manual, with the results indicated above. ERVICE TE HNICIAN PERMIT NO. ATE: TIME: AM PM EUST 'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. DISTRIBUTOR 0 Brooks Equipment Company,Inc. Range Hood Systems Repo SE NICE COMPANY DATE OF�SQFA/I TIME A.M. P.M. � ANNUAL SEMI-ANNUAL RECHARGE tN LiATION RENOVATION New -LOJATION OF SYSTEM CYLINDERSp ( UL 300 YES ❑NO + {� C MA FACTURER MO_DEL\NUMBER WET DRY CHEMICAL ,�uL 07- CYLINDER SIZE MASTER CYLINDER SIZE E CYLINDER SIZE SLAVE FUSE LINKS 360°F. FUSE LINKS 450°F. FUSE LINKS 500°F. OTHER n boorE�C�U�S'TOfuIE , Name FUEL SHUT-OFF ELECTRIC GAS SIZE Address 9 y SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE city .•( StateMZIP MANUFACTURER'S MANUAL REFERENCE Telephone Store No. PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager COOKING APPLIANC L A IONS: LEFT TO RIGHT 1. All appliances properly covered w/correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w/correct nozzles '� 21. Check travel of cable nuts/S-hooks 3. Check positioning of all nozzles ) 22. Piping&conduit securely bracketed 4. System installed in accordance w/MFG UL listing 23. Proper separation between fryers&flame 5. Hood/duct penetrations sealed w/weld or UL device 24. Proper clearance-flame to filters 6. Check if seals intact,evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same 26. All filters in place 8. Pressure gauge in proper range(If gauged) 27. Fuel shut-off in on position 9. Check cartridge weight(If applicable) 28. Manual&remote set/seals in place 10. Hydrostatic test date 29. Replace systems covers 11. 6 year maintenance date 30. System operational&seals in place 1/ 12. Inspect cylinder and mount 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder&mount 14. Test for proper operation from remote 33. Fan warning sign on hood 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 1/ 16. Check operation of gas valve 35. Proper hand portable extinguishers 17. Clean nozzles 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place 37. Service&Certification tag on system 19. Check fuse links and clean NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: ,ft VIC +C' � On this date, this range hood fire suppression system-was inspected and operationally tested in accordance with the fire suppressiog system requirements of NFPA17 or 17A, 9P and the manufacturer's manual, with the results indicated above. x SERVICE TECHNICIAN PERMITNO. ATE: TIME: At1A PM !CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. DISTRIBUTOR eBrooks Equipment Company,Inc. Range Hood systems Report SERVICE COMPANY DATE AFIG�� TIME A.M. P.M. tl _ ff TTT ANNUAL SEMI-ANNUAL RECHARGE INSTALLATION RENOVATION �y# LOC !ON OF SYSTEM CYLINDERS(, l UL 300 XS QNO M FACTURER MODEL NUMBER WET DRY CHEMICAL CYLI DER SIZE MASTER CYLINDER SIZE SLAVE CYLINDER SIZE SLAVE FUSE LINKS 360°F. FUSE LINKS 450°F. FUSE LINKS 500°F. OTHER CUITOM ^ 6LK2, T Name ('; jj�� FUEL SHUT-OFFELECTRIC GAS IZE Address (L4 `'# SERIAL NUMBER LAST HYDRO TEST DATE LAST RECHARGE DATE City State ZIP ' MANUFACTURER'S MANUAL REFERENCE ..Telephone Store No. PAGE NUMBER: DRAWING NUMBER: DATE Owner or Manager COOKING APPLIANCE LOCATIONS: LEFT TO RIGHT 1. All appliances properly covered w/correct nozzles 20. Replaced fuse links 2. Duct and plenum covered w/correct nozzles 21. Check travel of cable nuts/S-hooks - 3. Check positioning of all nozzles. 22. Piping&conduit securely bracketed _ 4. System installed in accordance w/MFG UL listing 23. Proper separation between fryers&flame 5. Hood/duct penetrations sealed w/weld or UL device 24. Proper clearance-flame to filters 6. Check if seals intact, evidence of tampering 25. Exhaust fan in operating order 7. If system has been discharged, report same 26. All filters in place 8. Pressure gauge in proper range(If gauged) 27. Fuel shut-off in on position 9. Check cartridge weight(If applicable) 28. Manual&remote set/seals in place 10. Hydrostatic test date 29. Replace systems covers ` 11. 6 year maintenance date 30. System operational&seals in place 12. Inspect cylinder and mount 4� 31. Slave system operational 13. Operate system from terminal link 32. Clean cylinder&mount !� 14. Test for proper operation from remote 33. Fan warning sign on hood A-,- 15. Check operation of micro switch 34. Personnel instructed in manual operation of system 16. Check operation of gas valve 35. Proper hand portable extinguishers �- 17. Clean nozzles 36. Portable extinguishers properly serviced 18. Proper nozzle covers in place " 37. Service&Certification tag on system 19. Check fuse links and clean G� NOTE DISCREPANICES OR DEFICIENCIES BELOW COMMENTS: On this date, this range hood fire suppression system was.inspected and operationally tested in accordance with the fire suppressio stem-requirements of NFPA17 or 17A 96 and the manufacturer's manual,with the results indicated above. r R CE TECHNICIAN PERMIT NO. I ATE. TIME: AM PM CUSTOMER'S AUTHORIZED AGENT The above service technician certifies that the system was personally inspected and found conditions to be as indicated on this report. ' ®1STR113UTOR ®Brooks Equipment Company,Inc. f (aw SPRINKLER SYSTEM CHECKLIST Date: Name: Location: N/A YES NO Sprinkler system plan and facility layout provided FDC correct size FDC accesible-E Tamper switches in place Flow switch in place All sprinkler heads have proper clearance*- FDC riser piping correct size Letter on file from contractor per NFPA 13 Inspector -+ 717 TOWN OF QUEENBURY RANGE HOOD SUPPRESSION WORKSHEET LOCATION: r- ' DATE: I �; INSPECTOR: SYSTEM INFORMATION MAKE: MODEL: SIZE: SYSTEM DATA TESTING DATA PASS FAIL I I PASS FAIL All appliances properly covered Nozzle caps off System monitored by fire alarm Fire alarm activation Nozzle protection in plenum Central Station Monitored Hood filters ]Gas valve off "K" Extinguisher Exhaust hood On Fusible Links All appliances shutdown Nozzle Caps Manual Actaution 10720' Range Hood Operational UL 300 Appliance layout vs. drawings 16"deep fryer/open flame TOWN OF QUEENSURY RANGE HOOD SUPPRESSION WORKSHEET LOCATION: DATE: 7 INSPECTOR: SYSTEM INFORMATION MAKE: MODEL: SIZE: SYSTEM DATA TESTING DATA PASS FAIL PASS FAIL All appliances properly covered Nozzle caps off System monitored by fire alarm Fire alarm activation Nozzle protection in plenum Central Station Monitored Hood filters Gas valve off "K" Extinguisher Exhaust hood On Fusible Links All appliances shutdown Nozzle Caps Manual Actaution 10720' Range Hood Operational UL 300 Appliance layout vs. drawings 16"deep fryer/open flame Fire Control Systems Inc. Page 1 TGE-BEER GARDEN _ --._� Date 040509 HYDRAULIC CALCULATIONS for Project name: The Great Escape Six Flags Location: Renovations to the Beer Garden Drawing no: FP-1 Date: 4/04/09 1 - Design _,� �- �,.____._._.._. Remote area number: RA-1 REV-1 Remote area location: Dining Area Occupancy classification: Light Hazard Density: .10-Gpm/SgFt Area of application: 2535-SgFt Coverage per sprinkler: 100-Sq Ft Type of sprinklers calculated: Quick Response Uprights No.of sprinklers calculated: 33 In-rack demand: n/a-GPM Hose streams: 100-GPM Total water required(including hose streams): 723-GPM @ 72- Psi Type of system: Dry Pipe System Volume of dry or preaction system: 250-Gal Water supply information Date: Location: Source: Queensbury Water Department Name of contractor: Fire Control Systems Inc. Address: 104 Reynolds Road, Fort Edward, New York 12828 Phone number: 518-747-2567 Name of designer: CJC Authority having jurisdiction:Town of Queensbury NY Notes:(Include peaking information or gridded systems here.) .10/1500 Increased 30%for Dry System = .10/1950 .10/1950 Increased 30%for Slope= .10/2535 Water Supply Curve (C) Fire Control Systems Inc. Page 2 TGE-BEER GARDEN Date 040509 City Water Supply: Demand: C1 -Static Pressure : 91 D1 - Elevation 9.597 C2-Residual Pressure: 81 D2-System Flow 622.945 C2- Residual Flow 1400 D2-System Pressure 71.422 Hose (Adj City) Hose ( Demand) 100 D3-System Demand 722.945 Safety Margin 16.634 150 140 130 P 120 R 110 E 100 C1 S 90 C2 S 80 D2 U 70 na R 60 E 50 40 30 20 4 10 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 Fire Control Systems Inc. Page 3 TGE-BEER GARDEN Date 040509 SUPPL Y ANAL PSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 91.0 81 1400.0 88.056 722.94 71.422 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 1 G 22.16 5.6 7.19 15.02 is 19.16 5.6 8.75 16.57 1 EE 16.0 5.6 11.33 18.85 1 H 22.16 5.6 7.26 15.09 1 T 19.16 5.6 8.82 16.63 1 FF 16.0 5.6 11.4 18.91 11 22.16 5.6 7.39 15.22 1 U 19.16 5.6 8.96 16.76 1 GG 16.0 5.6 11.56 19.04 11 22.16 5.6 7.67 15.51 1 V 19.16 5.6 9.25 17.03 1 H H 16.0 5.6 11.89 19.31 1 K 22.16 5.6 8.02 15.85 1X 19.16 5.6 9.6 17.35 111 16.0 5.6 12.29 19.64 2A 22.16 5.6 8.65 16.47 2E 19.16 5.6 10.26 17.93 21 16.0 5.6 13.04 20.22 2B 22.16 5.6 9.33 17.11 2F 19.16 5.6 10.96 18.54 2J 16.0 5.6 13.84 20.83 2C 22.16 5.6 10.46 18.11 2G 19.16 5.6 12.13 19.5 2K 16.0 5.6 15.16 21.8 2D 22.16 5.6 11.6 19.08 2H 19.16 5.6 13.31 20.43 2L 16.0 5.6 16.5 22.75 1 A 22.16 5.6 21.63 26.05 1 L 19.16 5.6 23.66 27.24 1 Y 16.0 5.6 28.2 29.74 105 11.0 40.07 104 11.0 40.14 103 11.0 40.23 102 11.0 40.3 101 11.0 40.39 120 11.0 40.55 1 F 22.16 5.6 7.17 15.0 1 R 19.16 5.6 8.73 16.55 1 D D 16.0 5.6 11.31 18.83 112 11.0 17.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 Fire Control Systems Inc. Page 4 TGE-BEER GARDEN Date 040509 NODE ANALYSIS(cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 111 11.0 17.57 110 11.0 17.7 109 11.0 17.92 108 11.0 18.39 107 11.0 18.96 150 11.0 19.98 151 11.0 21.07 152 11.0 22.88 153 11.0 24.69 106 11.0 29.18 100 11.0 40.7 TOR 2.0 48.81 BOR 2.0 55.97 BKFL 2.0 56.43 UG 1 2.0 62.92 100.0 TEST 0.0 71.42 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Fire Control Systems Inc. Page 5 TGE-BEER GARDEN Date 040509 Nodes Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe """ Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 1 G 22.16 5.60 15.02 1.25 0.0 9.250 100 7.192 to 0.0 0.0 1.299 is 19.16 15.02 1.38 0.0 9.250 0.0282 0.261 Vel = 3.22 is 19.16 5.60 16.57 1.25 0.0 10.790 100 8.752 to 0.0 0.0 1.369 1 EE 16.00 31.59 1.38 0.0 10.790 0.1117 1.205 Vel = 6.78 1 EE 16.00 5.60 18.84 1.25 1 E 2.141 8.950 100 11.326 to 1 T 4.282 6.423 2.166 111 11.00 50.43 1.38 0.0 15.373 0.2654 4.080 Vel = 10.82 0.0 111 50.43 17.572 K Factor= 12.03 1 H 22.16 5.60 15.09 1.25 0.0 9.250 100 7.258 to 0.0 0.0 1.299 1 T 19.16 15.09 1.38 0.0 9.250 0.0284 0.263 Vel = 3.24 1 T 19.16 5.60 16.63 1.25 0.0 10.790 100 8.820 to 0.0 0.0 1.369 1 FF 16.00 31.72 1.38 0.0 10.790 0.1125 1.214 Vel = 6.80 1 FF 16.00 5.60 18.91 1.25 1 E 2.141 9.040 100 11.403 to 1 T 4.282 6.423 2.166 110 11.00 50.63 1.38 0.0 15.463 0.2673 4.134 Vel = 10.86 0.0 110 50.63 17.703 K Factor= 12.03 11 22.16 5.60 15.22 1.25 0.0 9.250 100 7.390 to 0.0 0.0 1.299 1 U 19.16 15.22 1.38 0.0 9.250 0.0290 0.268 Vel = 3.26 1 U 19.16 5.60 16.76 1.25 0.0 10.790 100 8.957 to 0.0 0.0 1.369 1 GG 16.00 31.98 1.38 0.0 10.790 0.1143 1.233 Vel = 6.86 1 GG 16.00 5.60 19.04 1.25 1 E 2.141 9.040 100 11.559 to 1 T 4.282 6.423 2.166 109 11.00 51.02 1.38 0.0 15.463 0.2712 4.194 Vel = 10.94 0.0 109 51.02 17.919 K Factor= 12.05 11 22.16 5.60 15.51 1.25 0.0 9.250 100 7.669 to 0.0 0.0 1.299 1 V 19.16 15.51 1.38 0.0 9.250 0.0299 0.277 Vel = 3.33 1 V 19.16 5.60 17.03 1.25 0.0 10.790 100 9.245 to 0.0 0.0 1.369 1HH 16.00 32.54 1.38 0.0 10.790 0.1180 1.273 Vel = 6.98 1 H H 16.00 5.60 19.30 1.25 1 E 2.141 9.120 100 11.887 to 1 T 4.282 6.423 2.166 108 11.00 51.84 1.38 0.0 15.543 0.2793 4.341 Vel = 11.12 0.0 108 51.84 18.394 K Factor= 12.09 1 K 22.16 5.60 15.85 1.25 0.0 9.250 100 8.015 to 0.0 0.0 1.299 ix 19.16 15.85 1.38 0.0 9.250 0.0312 0.289 Vel = 3.40 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Fire Control Systems Inc. Page 6 TGE-BEER GARDEN Date 040509 Nodes Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 1 X 19.16 5.60 17.36 1.25 0.0 10.790 100 9.603 to 0.0 0.0 1.369 111 16.00 33.21 1.38 0.0 10.790 0.1225 1.322 Vel = 7.12 111 16.00 5.60 19.63 1.25 1 E 2.141 9.120 100 12.294 to 1 T 4.282 6.423 2.166 107 11.00 52.84 1.38 0.0 15.543 0.2893 4.497 Vel = 11.33 0.0 107 52.84 18.957 K Factor= 12.14 2A 22.16 5.60 16.47 1.25 0.0 9.250 100 8.648 to 0.0 0.0 1.299 2E 19.16 16.47 1.38 0.0 9.250 0.0335 0.310 Vel = 3.53 2E 19.16 5.60 17.93 1.25 0.0 10.790 100 10.257 to 0.0 0.0 1.369 21 16.00 34.4 1.38 0.0 10.790 0.1308 1.411 Vel = 7.38 21 16.00 5.60 20.22 1.25 1 E 2.141 9.120 100 13.037 to 1 T 4.282 6.423 2.166 150 11.00 54.62 1.38 0.0 15.543 0.3076 4.781 Vel = 11.72 0.0 150 54.62 19.984 K Factor= 12.22 2B 22.16 5.60 17.11 1.25 0.0 9.250 100 9.331 to 0.0 0.0 1.299 2F 19.16 17.11 1.38 0.0 9.250 0.0360 0.333 Vel = 3.67 2F 19.16 5.60 18.54 1.25 0.0 10.790 100 10.963 to 0.0 0.0 1.369 2J 16.00 35.65 1.38 0.0 10.790 0.1397 1.507 Vel = 7.65 2J 16.00 5.60 20.83 1.25 1 E 2.141 9.040 100 13.839 to 1 T 4.282 6.423 2.166 151 11.00 56.48 1.38 0.0 15.463 0.3273 5.061 Vel = 12.12 0.0 151 56.48 21.066 K Factor= 12.31 2C 22.16 5.60 18.11 1.25 0.0 9.250 100 10.458 to 0.0 0.0 1.299 2G 19.16 18.11 1.38 0.0 9.250 0.0400 0.370 Vel = 3.88 2G 19.16 5.60 19.50 1.25 0.0 10.790 100 12.127 to 0.0 0.0 1.369 2K 16.00 37.61 1.38 0.0 10.790 0.1542 1.664 Vet = 8.07 2K 16.00 5.60 21.81 1.25 1 E 2.141 9.040 100 15.160 to 1 T 4.282 6.423 2.166 152 11.00 59.42 1.38 0.0 15.463 0.3594 5.558 Vel = 12.75 0.0 152 59.42 22.884 K Factor= 12.42 2D 22.16 5.60 19.08 1.25 0.0 9.250 100 11.605 to 0.0 0.0 1.299 2H 19.16 19.08 1.38 0.0 9.250 0.0439 0.406 Vel = 4.09 2H 19.16 5.60 20.43 1.25 0.0 10.790 100 13.310 to 0.0 0.0 1.369 2L 16.00 39.51 1.38 0.0 10.790 0.1690 1.823 Vel = 8.47 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Fire Control Systems Inc. Page 7 TGE-BEER GARDEN Date 040509 Node1 Elev1 K Oa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 2L 16.00 5.60 22.75 1.25 1 E 2.141 8.950 100 16.502 to 1 T 4.282 6.423 2.166 153 11.00 62.26 1.38 0.0 15.373 0.3919 6.024 Vel = 13.35 0.0 153 62.26 24.692 K Factor= 12.53 1 A 22.16 5.60 26.05 1.25 0.0 9.250 100 21.635 to 0.0 0.0 1.299 1 L 19.16 26.05 1.38 0.0 9.250 0.0782 0.723 Vel = 5.59 1 L 19.16 5.60 27.23 1.25 0.0 10.790 100 23.657 to 0.0 0.0 1.369 1 Y 16.00 53.28 1.38 0.0 10.790 0.2938 3.170 Vel = 11.43 1 Y 16.00 5.60 29.74 1.25 1 E 2.141 8.120 100 28.196 to 1 T 4.282 6.423 2.166 105 11.00 83.02 1.38 0.0 14.543 0.6675 9.707 Vel = 17.81 105 11.00 0.0 3 0.0 7.000 100 40.069 to 0.0 0.0 0.0 104 11.00 83.02 3.26 0.0 7.000 0.0101 0.071 Vel = 3.19 104 11.00 0.0 3 0.0 9.000 100 40.140 to 0.0 0.0 0.0 103 11.00 83.02 3.26 0.0 9.000 0.0101 0.091 Vel = 3.19 103 11.00 0.0 3 0.0 7.000 100 40.231 to 0.0 0.0 0.0 102 11.00 83.02 3.26 0.0 7.000 0.0101 0.071 Vel = 3.19 102 11.00 0.0 3 0.0 9.000 100 40.302 to 0.0 0.0 0.0 101 11.00 83.02 3.26 0.0 9.000 0.0102 0.092 Vel = 3.19 101 11.00 0.0 3 0.0 15.000 100 40.394 to 0.0 0.0 0.0 120 11.00 83.02 3.26 0.0 15.000 0.0101 0.152 Vel = 3.19 120 11.00 0.0 3 1 T 14.388 1.160 100 40.546 to 0.0 14.387 0.0 100 11.00 83.02 3.26 0.0 15.547 0.0102 0.158 Vel = 3.19 0.0 100 83.02 40.704 K Factor= 13.01 1 F 22.16 5.60 15.00 1.25 0.0 9.250 100 7.175 to 0.0 0.0 1.299 1 R 19.16 15.0 1.38 0.0 9.250 0.0282 0.261 Vel = 3.22 1 R 19.16 5.60 16.55 1.25 0.0 10.790 100 8.735 to 0.0 0.0 1.369 1 DD 16.00 31.55 1.38 0.0 10.790 0.1114 1.202 Vel = 6.77 1 DD 16.00 5.60 18.83 1.25 1 E 2.141 8.950 100 11.306 to 1 T 4.282 6.423 2.166 112 11.00 50.38 1.38 0.0 15.373 0.2649 4.072 Vel = 10.81 112 11.00 0.0 3 0.0 7.000 100 17.544 to 0.0 0.0 0.0 111 11.00 50.38 3.26 0.0 7.000 0.0040 0.028 Vel = 1.94 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Fire Control Systems Inc. Page 8 TGE-BEER GARDEN Date 040509 Node1 Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 111 11.00 50.43 3 0.0 9.000 100 17.572 to 0.0 0.0 0.0 110 11.00 100.81 3.26 0.0 9.000 0.0146 0.131 Vel = 3.87 110 11.00 50.63 3 0.0 7.000 100 17.703 to 0.0 0.0 0.0 109 11.00 151.44 3.26 0.0 7.000 0.0309 0.216 Vel = 5.82 109 11.00 51.02 3 0.0 9.000 100 17.919 to 0.0 0.0 0.0 108 11.00 202.46 3.26 0.0 9.000 0.0528 0.475 Vel = 7.78 108 11.00 51.85 3 0.0 7.000 100 18.394 to 0.0 0.0 0.0 107 11.00 254.31 3.26 0.0 7.000 0.0804 0.563 Vel = 9.78 107 11.00 52.84 3 0.0 9.000 100 18.957 to 0.0 0.0 0.0 150 11.00 307.15 3.26 0.0 9.000 0.1141 1.027 Vel = 11.81 150 11.00 54.62 3 0.0 7.000 100 19.984 to 0.0 0.0 0.0 151 11.00 361.77 3.26 0.0 7.000 0.1546 1.082 Vel = 13.91 151 11.00 56.48 3 0.0 9.000 100 21.066 to 0.0 0.0 0.0 152 11.00 418.25 3.26 0.0 9.000 0.2020 1.818 Vel = 16.08 152 11.00 59.42 3 0.0 7.000 100 22.884 to 0.0 0.0 0.0 153 11.00 477.67 3.26 0.0 7.000 0.2583 1.808 Vel = 18.36 153 11.00 62.25 3 2V 9.592 4.250 100 24.692 to 0.0 9.592 0.0 106 11.00 539.92 3.26 0.0 13.842 0.3240 4.485 Vel = 20.75 106 11.00 0.0 4 5V 31.951 80.160 100 29.177 to 1 T 18.795 50.746 0.0 100 11.00 539.92 4.26 0.0 130.906 0.0881 11.527 Vel = 12.15 100 11.00 83.03 4 iv 6.39 30.290 100 40.704 to 0.0 6.390 3.898 TOR 2.00 622.95 4.26 0.0 36.680 0.1147 4.207 Vel = 14.02 TOR 2.00 0.0 4 1 D 26.313 9.000 100 48.809 to 1 B 11.277 53.376 0.0 BOR 2 622.95 4.26 1 V 6.39 62.376 0.1147 7.156 Vel = 14.02 1 E 9.397 BOR 2 0.0 4 1 G 2.633 2.990 120 55.965 to 0.0 2.633 0.0 BKFL 2.00 622.95 4.26 0.0 5.623 0.0820 0.461 Vel = 14.02 BKFL 2.00 0.0 4 1 E 13.167 2.460 120 56.426 to 1 G 2.633 15.800 5.000 * Fixed loss=5 UG1 2.00 622.95 4.26 0.0 18.260 0.0819 1.495 Vel = 14.02 UG 1 2.00 H 100 99.99 6 1 E 20.084 500.000 140 62.921 to 1 T 43.037 67.425 0.866 TEST 0 722.94 6.16 1 G 4.304 567.425 0.0135 7.635 Vel = 7.78 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 Fire Control Systems Inc. Page 9 TGE-BEER GARDEN Date 040509 Nodes Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf TEST 722.94 71.422 K Factor= 85.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ff MARS# AUS OFFf(--L T01"I Pf"Q?f'eP11' Wry 742 �q?f Pg , ,tt.e n�?ttr?/, Y I M04 lYQtrte of Na, tural lieg ?itlt ,,, A Good Place to Line " PLAN REVIEW Beer Garden 2009-071 4/1/2009 I have reviewed the submitted drawings and submittals for the above project, and offer the following comments. (based on 3/31/09 submittals) X) Provide complete sprinkler plans, NFPA 13 compliant 2) Provide NFPA compliant fire alarm plan w/exterior strobe at FDC 3) Specify which model Handi Lift is being installed and a QEI certified inspection will be required 4) FM witness of Ansul test and fan shutdown required. 5) Please provide additional information related to wall and ceilings coverings. ` 'I Ii t paperwork supplied addresses the ceiling hangings only. What are the wall and stage coverings made of? A concern still exists that the aggregate area of wall and ceiling coverings made of fire resistive materials may not exceed 10%. 6) Truss ID signage is required at all entrance and egress along with the FDC location. Fire Marshal Michael J Palmer 742 Bay Road Queensbury NY 12804 518 761 8206 firemarshal@queensbury.net Fire Marshal 's Office - Phone: 518-761-8206 - Fax: 518-745-4437 firemarshal fteensbunt.net - zvzvzv.gueensbunj.net FIRE MARSHAL'S OFFICE Tozvn of Queensbury 742 Bay Road, Queensbury, NY 12804 " Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Beer Garden 2009-071 3/24/2009 I have reviewed the submitted drawings and submittals for the above project, and offer the following comments 1) Provide details and specifications for proposed wheelchair lift Ochange terminology on drawings from Stage to Platform to meet code definition 0 Provide complete exit and emergency lighting layout plan -4 4) Provide complete NFPA 13 compliant sprinkler plans it 5) Provide complete NFPA 72 fire alarm system plans, including strobe device at FDC 6 Provide complete kitchen appliance layout plan Provide complete details for kitchen hood and Ansul system 8) Provide detailed description of material being proposed for ceiling covering, including flame retardant certification and a detailed drawing showing how the material will be hung, spacing between the panels and the projection of the material from the mounting location 9 Fire extinguisher location to be discussed 0 FM to provide elevator posting, Max OCC signage and FD Blue signage Fire Marshal Michael J Palmer 742 Bay Road Queensbury NY 12804 518 761 8206 Fi r e M a r s h a l 's Off i c e - P h o n e: 518-761-8206 - F a x: 518-745-4437 firemarshal@queensbury.net - v 7wzv. ueensbun1.net TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 " Home of Natural Beauty ... A Good Place to Live " Meeting Notes Title or Purpose: New construction Date: March 19, 2009 Location: Six Flags Attendees: FM Palmer, DFM Stillman , Brian Martineau, Dean Hyatt, Bob Culver Items Discussed: - Met at beer Garden building, being converted to a restaurant. Discussed issues with sprinkler protection due to a fabric type material being installed for the ceiling. FM office left it up to the design professionals to design and stamp a system that is NFPA compliant. Shown an area behind the building where two 500 gallon propane tanks will be buried. FM office will be called for oversight inspections. FM office approved removal of (1 ) yard hydrant directly behind the beer garden buiolding Action Required: None Notes prepared FM Palmer by: Distribution: DFM, File COMMUNITY DEVELOPMENT OFFICE •Animal Control 518.761.8202 • Building&Codes 518.761.8256 • Executive Director 518.761.8221 • Fire Marshal 518.761.8206 • Planning 518.761.8220 • Zoning 518.761.8238 FIRE MARSHAL'S OFFICE Tozun of Queensbury 742 Bay Road, Queensbury, NY 12804 " Home of Natural Beauty ... A Good Place to Live " Meeting Beer garden-Great Escape 1/27/2009 Discussed renovation of Beer Garden and reviewed plans. J11),Fire extinguisher locations 2) Installing sprinkler system- advised submit plans-FDC location 3) Installing fire alarm system- working with NYFS, discussed ansul & fan shutdown tie-in Y Buffalo Equip installing suppression systems & appliances- need plans & lllayout Propane tank or tanks- location & quantity Remove & relocate hydrant behind beer garden, plan is to use water main for sprinkler system. Plans show a W.C.Lift for platform. Const type- 5B 9) Info on flame retardant fabric in ceiling above sprinklers 10) Max OCC- 296 Deputy Fire Marshal Gary K Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 firemarshal@queensbury.net Fire Marshal 's Office - Phone: 518-761-8206 - Fax: 518-745-4437 firemarslial@queensbunj.net - zvzvzv.queensbunt.net 2�10 CA 5p 11l , t �r tf �S APR-8-2008 10:47R FROM:JOSEPH MCGRATH (518)-477-2369 T0:7454437 P.2 r Plan Review Checklist Non-Residential Occupancies January 2008 NYS BUILDING CODE(BC) Building: �a NYS FIRE CODE(FC) Location: NYS PLUMBING CODE(PC) Address: NYC MECHANICAL CODE(MC) NYS FUEL GAS CODE(FGC) Date: 2(p ►nl ` � NYS ENERGY CODE(ECC) Reviewer: THIS CHECKLIST CONSISTS OF EIGHT(8)PAGES LEGEND: NR■Not Required NS = Not Shown NA =Not Applicable No. Topic Code Page Required Actual Section No. or Allowed 1 Jurisdiction BC-101.2 1 2 Flood Plain BC-1612 287 3 Separated or Non-Separated BC-302.3 18 Occupancies* 4 Occupancy BC-302 17 5 Type of Construction BC-Table 601 77 26 6 No. of Sleeping Units/Level BC-202 13 91 No. of Units—Total BC-31.0 30 No. of Occupants BC-Table 1004.1.2 189 !p 7 Covered Malls BC402 33 Hi-Rise(75' Rule) BC403 35lJa. Atriums BC404 37 8 Basement Definition BC-502.1 67l f/> 9 Heights & Buildine Areas Maximum Tabular Area BC-Table 503 68 &,p00 (10"7 Maximum Tabular Height BC-Table 503 68 40` 36} Maximum Stories BC-Table 503 68 1 Mezzanines BC-505 69 t3/P Note: * Non-separated occupancies impose the most restrictive requirements. Page 1 of 8 1✓ / � 11,;,5 }JCt` Srp( tS 12 IFL-V V L4___ 1 4-Q0 �I 3 ram" �- � ►� - - i s 'Z12- APR-8-2008 10:48A FROM:JOSEPH MCGRATH C518)-477-2369 TO:7454437 P.3 PLAN REVIEW CHECKLIST CONTINUED No. Topic Code Page Required Actual Section No. or Allowed 10 Sprinkler System BC-903 160 01! (o D - 1 Basement Sprinkler BC-903.2.10.1 161 f, Water Source Sprinkler BC-903.3.5 163 �,.,�►J. Water Source Site BC-508.1 33 11 Frontage& Sprinkler Credit Area Modifications(calc.) BC-506 70 Zvo% Height Modifications BC-504 69 12 Height& Area Summary Tabular Area BC-Table 503 68 (o,ovo Frontage Credit BC-506.2 70 Sprinkler Credit BC-506.3 70 I Z,060 � .. Minimum Building Area BC-506.3 70 lZ216wip (p7 50 Total Allowable Area 13 Fire Apparatus Road FC-503.1 31 (150' Rule) 14 Exterior Walls Distance Separation * BC-Table 602 77 O Exterior Wall Openings BC-Table 704.8 82 NGyJ Parapets BC-Table 704.11 83 F'rL Exterior Wall Coverings BC-Table 1405.2 241 Combustible Exterior Walls BC-1406 244 ©�- 15 Fire Rated Construction Incidental Use Areas BC-Table 302.1.1 17 Accessory Occupancy BC Table 302.2 18 Mixed Occupancy BC-Table 302.3.3 19 Fire Walls BC-705 84LtYGel 2 � Fire Barrier BC-706 86 Shaft Enclosure BC-707 87 Fire Partition (Tenant Sep.) BC-708 89 Exception BC-302.3.2 18 Smoke Barriers BC-709 90 Opening Protectives BC-Table 715.3 95 Fire Blocking BC-717 101 Draft Stopping BC-717 102 16 Space Min, Room Dimensions BC-1208.1 235 dK - Min. Ceiling Height BC-1208.1 235 * Distance separations are doubled if fire fighting water is not available, FC-508, Page 33 Page 2 of 8 APR-8-2008 10:48A FROM:JOSEPH MCGRATH (518)-477-2369 TO:7454437 PA PLAN REVIEW CHECKLIST CONTINUED No. Topic Code Page Required Actual Section No. or Allowed 17 Ventilation (Nat. or Mech.) BC-1203 233 18 Light(Nat. or Mech.) BC-1205 234 19 Exi s One Exit Permitted BC-Table 1014.1 204 Stair Enclosure BC-1019.1 208 N/P Emergency Egress BC-1025 217 " Distance of Travel BC-Table 1015.1 206 Exit Passageways BC-1020 210 Corridor Width BC-1016 206 N/f' Occupant Load BC-1004 189 2°t� Capacity of Exits (talc.) BC-Table 1005.1 190 p, Corridor Wall Fire Rating BC-Table1016.1 206 =A4-•A Corridor Dead End BC-1016.3 207 0/4 Door Width BC-1008.1.1 193 /JJ(o Door Swing, 13C-1009.1.2 193 0 Panic Hardware BC-1008.1.9 197 20 Stairs - S-rx-� ffU-A Riser BC-1009.3 198 _I ��Ak - Tread BC-1009.3 198 1" m)" O Y-- Width BC-1009.1 198 3�' m+N 42" Headroom BC-1009.2 198 OK- Vertical Rise BC-1009.6 199 ram" Handrails BC-1009.4 199 r4p 21 Structural Snow Loading-Ground BC-Fig. 1608.2 274 -70 PEP Snow Loading- Roof(calc.) ASCE 7-98 Drifting Snow BC-1608-7 273 Ponding BC-1608.3.5 273 Floor Loading BC Table 1607.1 269 Balcony Loading BC Table 1607.1 269 Wind Loading(calc.) . BC-1609 273 1514n,e), Roof Walls Windows Seismic Loading (calc.) 291 Foundation Depth 338 Urlr�l4i�tJ ft%UmE 22 Interior Finishes BC-Table 803.5 338 23 Swimming Pools 13C-3109 532 /P Page 3 of 8 APR-8-2008 10:49A FROM:JOSEPH MCGRATH (518)-477-2369 TO:7454437 P.5 PLAN REVIEW CHECKLIST CONTINUED No. Topic Code Page Required Actual Section No. or Allowed 24 Sun Rooms BC Appendix 1 581 N�P 25 Electrical Exit Signs BC-1011 201 'CD Emergency Lights BC-1006 191 OU) Emergency Power BC-2702 517 26 HC ACCESS Exempt Buildings BC-1104.4 221 alb. Parking BC-Table 1106.1 222 Route BC-1104 220 0� Entrance BC-1105 221 0 No. of Sleeping Rooms BC-Table 1107.6.1.1 224 /p No. of Dwelling Units BC-1107.E 223 Special Occupancies BC-1108 225 Toilet Facilities — f.1oNi:,:F BC-1109.2 228 NIP Sinks BC-1109.3 228 Kitchens BC-1 109.4 229 Storage BC-1109.8 229 Dress, Fit,Locker Rms. BC-1109.12.2 229 Point of Sales BC-1109-12.3 229 Areas of Refuge BC-1007.6 192 N AP Signage BC-1110 230 qt<_ Tactile Exit Signs BC-1011.3 202 p� Supplemental HC Req'mts Appendix E 569 27 SPECIAL INSPECTIONS BC-1704 318 28 Fire Protection Equipment Fire Safety &Evacuation FC-404 25 Hazard Communication FC-407.5 27 Tenant Identification FC-408.11.2 30 High Piled Storage FC-503.1.3 31 Premise Identification FC-505 32 Key Box FC-506 33 Room Identification FC-510 34 Central Station Monitoring FC-901.9 54 Sprinkler Systems FC-903 57 c5K— v1� Other Extinguishing System FC-904 61 Kitchen Hood Extinguisher FC-610.3 43 ts� Note:Fire Protection Equipment continued on Continued on pg.5 page 5. Page 4 Of 8 Ht-K-b—dW08 10:48A FROM:JOSEPH MCGRATH c518)-477-2369 TO:7454437 P.6 PLAN REVIEW CHECKLIST CONTINUED No. Topic Code Page Required Actual Section No. or Allowed - 28 Fire Protect._Equipment - Continued from ogee 4. "K"Extinguisher FC-904.11.5 64 Standpipe Systems FC-905 64 Fire Extinguishers FC-906 66 Fire Alarm Systems&SD •FC-907.2 68 Manual Fire Alarm Boxes FC-907.4 75 Smoke Alarms FC-907.2.10 70 Audible Notification Device FC-907.10 75 Duct Detectors FC-907.12 76 Fire Extinguishing Systems FC-907.14 76 Smoke Control FC-909 77 Smoke Vents FC-910 84 Fire Dept. Connection FC-912 88 Fire Pumps FC-913 88 Truss Placards NYCRR Part 1264 Motor Fuel Disp. Facilities FC-2203 175 High Piled Storage FC-2301 193 Hazardous Materials FC-2701 215 Operating Permits TOCP 208-107B Assistive Listening Devices NYCRR Part 1203 Shield Electrical Panels NFPA13(02 edition) 8.14.10.2 29 PLUMBING CODE Fixture Count PC-Table 403.1 19 Water Supply Service Pipe Size PC-603.1 31 Water/Sewer Separation PC-603.2 31 Fixture Pipe Size PC Table 604.5 33 Pipe Material—Service PC-Table 605.3 34 Pipe Material—Distribution PC-Table 605.4 34 Pipe Insulation EC-804.5 58 Backflow Prevention PC-Table 608.1 40 � Pipe Freezing PC-305.6 12 Sanit Darr rainagee Drain Pipe Size PC-Table 709.1 52 Drain Pipe Material AG Drainage&Vent PC-Table 702.1 46 UG Drainage&Vent PC Table 702.2 46 Building Sewer PC-Table 702.3 Vent Size PC Table 910.4 63 Pipe Hangers PC-Table 308.5 15 Air Admittance Valves PC-917 66 Page 5 of 8 APR-8-2008 10:49A FROM:JOSEPH MCGRATH (518)-477-2369 TO:7454437 P.7 PLAN REVIEW CHECKLIST CONTINUED No. Topic Code Page Required Actual Section No. or Allowed 30 -Mechanical Code Ventilation Rates MC-Table 403.3 26 Dryer Exhaust MC-504 36 Kitchen Exhaust MC-500 37 Kitchen Hoods MC-507 40 Kitchen Make-up Air MC-508 42 Air Plenums MC-602 51 (a Duct Construction MC-603 52 Duct Insulation MC-604 53 Smoke Duct Detectors MC-606 54 Fire&Smoke Dampers MC-607.5.1 55 Combustion Air MC-701 59 31 Fuel Gas Code Appliance Location FGC-303 16 Combustion Air FGC-304 16 8q Accessed Service FGC-306 20 Clearance to Combust. FGC-Table 308.2 22 ' Pipe Material FGC-403 57 Shut Off Valves FGC-409 62 Chimney Termination FGC-Fig. 503.5.4 68 Clothes Dryer Exhaust FGC-614 108 32 Energy Code Pipe Insulation-Heating EC-803.3.7 57 �(iz;nr4 U Duct Insulation-Sealing EC-803.28 46 _ Pipe Insulation-Hot Water EC-804.5 58 15L40 HWH Heat Trap EC-804.4 58 2 Climate Zone EC-Table 301.1 9 NYS COMcheck Compliance Report Computer Envelope Software Mechanical Required Lighting 32 Elevators&Conveying Sys. Hoistway Enclosures BC-3002.1 525 Emergency Signs BC-3002.3 252 AM, Hoistway Venting BC-3004 526 Machine Rooms BC-3006 526 Shunt Trip BC-3006.5 527 Plumbing System BC-3006.6 527 Page 6 of 8 APR-8-2008 10:49A FROM:JOSEPH MCGRATH (518)-477-2369 TO:7454437 P.8 PLAN REVIEW CHECKLIST CONTINUED SEISMIC REVIEW SUMMARY ITEM Value BCNYS BCNYS Code Section Page No. Site Class Table 1615.1.1 295 (default to site class D) Section 1615.1.1 292 S.(short period) Figure 1615(1) 293 SI(1 second period) Figure 1615(2) 294 F.(site coefficient-short) Table 1615.1.20) 296 F„(site coefficient-1 sec.) Table 1615.1.2(2) 296 S.(short period adjusted) Equation 16-38 292 S.,(1 sec. period adjusted) Equation 16-39 292 SDs(short period) Equation 16-40 292 SDI 0 sec. period) Equation 16-41 292 Seismic Use Group Table 1604.5 266 Seismic Design Category Table 1616.30) 299 (short period) Seismic Design Category Table 1616.3(2) 299 0 sec. period) Seismic Design Category This category determines the (most severe of above two) Design analysis and whether MEP systems must be braced Analysis Procedure Used Section 1616.6 300 Building Components Section 1621 315 Subject To Seismic Design Requirements: Architectural Section 1621.1.2 315 Mechanical Section 1621.1.3 315 Plumbing Section 1621.1.3 315 Electrical Section 1621.1.3 315 Page 7 of 8 APR-8-2008 10:49A FROM:J05EPH MCGRATH C518)-477-23G9 TO:7454437 P.9 PLAN REVIEW CHECKLIST CONTINUED NOTES FOR PREVIOUS REVIEW PAGES Page 8 Of 8 c a Sprinkler Main r 16'-0"o.c. 4r ob � . Uti -- I r + Speaker �v 30 AIC t !;' r s Wall. 1 1 Speaker t`7 � d ■ !k 1f { ' [fjP I *• OL 1 � 1 .lWINN L J I. Wsi►, 38 (72 to es `. "AI ine Fest Waus" Reflected Coiling Plan Planvow;Tow4r 30"tube duct Hanging Cables to Bottom of _ Bent 00 I M 0 i i M -� E �; SW-6128 L E "Blonde" ci Field verify hanging heights 10"Tassel o All Bldg Steel oo CO Fabric: 10oz. N "0 "Applause Synthetic Velour" �"} � Z SW-6130 IFR. +� N O Aladdin-yellow"Mannered Gold" n ing Decor Banners Parchment-white v (D_na Scale: 1/8"=1'-0" Royal-blue SW-6373 "Harvester" N L SW-6524 "Commodore" m Banner Hanging Positions L O 30"tube duct = on Amm a. N W � -J Z CO - -- Oki- j On , 0Unp Rol! L ,. ILI Wall Elevation Six Flags 1 B Scale: 1/8"=1'-0" I y ti 1 a � O O O o J 6 0 0 41 0 m - pI 0 0000 94 Ln -- O °boa cl)c o000 E� v 0 F7 I 0 41 I ° 0 E '^3 V/ - ,✓ _ r 1"•) ''�Y.f,,,''rr' :,/" .,Y :`' i 'j - , %`d /�! /f r r` ,: � .l', J, ,.I{i Y d. Jt t /''j"`• r y r�/� `' f-rF f'' �. f „s ''I�,<''Y,r f'J r` !,F fl J+' .r _`',.- - s fp rr � !r,'_r r rd",✓ {r .• r`Y .r""F rr`'` �. "r J`-,, - r r�'` d ',r / ��r�r" 1 F. •'f !¢l ,i'1 F r r f . ,/'r .f <�r't:/ �f�`r� ''if ,r ell/ `J rr`rr' lr r i fr to frr 1fi'l'd rlr,<s' Yd} ! './ !f_.+'' rl .r'/',• Ln 0 3'--10" 3l � 1 c � ,• .•°d: Jft,,,J',/ft't ,�,•P r %,ems„ �,,.�,,., r,/ r'`.., r� rr p`r,�,J` �'l•' ,•E'; f•'`"Y r`^`' �,' �•' � 'j I` f j 'rr'"r r '`r" 'r• �r f jF Y '{ ''J �.✓'/ r" '�,t` f,.rF •E - rt• .!• .Jrr ! - 'r '!/ ./, F ,,� ,/ / !� f O `',<r ,/ f� 'rr rf f`s°�f` tJ sf Jp.J t },/` 't'r f fr / �/ � :� °V d' i� �i` f f�' •'Jam` f%- -!' `'_I./ _ � / .f '' '' `'/ f,/" !` jF'<%,, `f ,r'' "J �/`..� � ./ f r r �' r:. fl - �. r ra ,`; ¢/ X 72 TABIES VIEIT ` </�., .!r / f�, ' r ,r` .j`;; r-f /• �; ,r'`r' ,-' 'iY i ,r .�'' f' 1! .n �% '.t''`�r''F j t","•'} X 7, 1�t� MLE BENCHE - ',s'`� +Jr '�rr�• ;r- ,� � ,r` ,/f ,J-` �r`� ,r ,/ rr; ,r`' ,r`� �,� J. !';� i`d''f A`'}r %, , r r' ;" ' J'.d',J ,'`J �'r ',A ''{ '` `,' -; ,= P. F4R 32 TABLES`) .+" f .+' J aJ J r' J f ! f 1 ✓' d rJ 1 ! t ✓ r J % rY• 7 r' r °r,d ar', f' J'/,., ✓ If Jr j it fJ r .f .sr r i s"J ' f% srr<• !'' ds - N y 3 m a 5,�� • .r,, :` r` t`. % _.^ .. s � ,,` ,r r ,F .d .j t� rj '!` ✓' ? r d� - "fj f r `z, f .!rY`J' .1 t F; , � jr / J •ra- s'r•` s' ✓'J �d' f sF: `j" � r. _- <_` -'<r` �� ,.�` ,�'�r'',r ,f fJ ' t'; f ✓'"f ` ,`-'r' F` ` Y'r` .f s rr'.d f 'r r'r ,�''/'f'y r'' ,�'' ` ,J �{<�``j`,,' _' d 'f'° t `f ,,""• ` �,'�f 'J`'' r`,;r -- - _J ,r ! 1J.F`f ' s° f ' r'':.r!;! ^''• .' ' '"'.,>J, r''�'j'J "`'•,f�,f�° ,r,.�``e, j fir'j :,°r f ja'`` s`'rf �f` t /°Yr; r ! , ,jfr fs"r✓' ,r,,. % �. :'�,.� ✓ ,'J r' i` r ,'" r'�J •'J ,,' ,r' f .Y ✓ r Jr a`' ,,." J r i- r '" r /r ,� l' "/ �` � r' `F `r� ,.r' r /,r' r'` ,,r,,' , ,t`rf r�r i ,J` .r_ F/ ''`` .°`` ,rr f .s'! -r ',t / r` i' .1 '! r `' :' - •Ja`" dJ t � i "''J '' r r' ' t .• r.- `! {ft £j fs - "Yr ,f ,r"f r,l ,✓' r° ,.'`; �'J,f` r i Cn rf,t rrf ,r i %2 r ` i ✓ j r fI J t r r r f e f ,f a r ,°`r .I t ,'' a �✓ Jf , / - r - `. / ,!✓ f,•' J r f/`d,!' f',:r '`,,i / f`f r/f/ _ s ,,r ifs'Y, r ! ''rr ,r'r rt`r,. f'a` ., ,Y` r J lr f ti / J N N CS U W s - ,: •r ,. r a / P -r- - r' % ,' .' j r' `-% � -{ r' '` ,, f .+! f rr Y, s !` { CL +' '.r' '`�f !r,r'`,, JJ' '" .-` y' / / ''`f f- f .`{`r ° /` /'`f a.r` %,s' rr .'' ,+° f,,'r`,,F„ 'r, rr ✓` 'f .�'r,/ ✓ s .f f"�J "r' f J�f y F r'/y,r0` /r. j r; J' � r, ,, ,r f �rl, r I f - .� ;�tt / s r i, ,,it �,', `� / Y✓ j r f r P ! ,✓ J`� j � '� / r r! j ✓` / f / ,,°` %,, `f, ,J ` - r'l I,1 / t"r s': % f F;` r - '` - r' ,,r" s' ' ,t ✓ .+ ,'`' ,i ,J't f j = s.- j � � ` �, I"`f` / t r ;�- 'I r r't/,.!`.'r`' !J ?Y,; /`_ i% ,r ,f f -f r f%��j ,`f / "1 {,` ✓'1' '�' ,{" �l s'r t f� ' i Y,:.d s",,"Yr,P'r tv� /,r /'�,ri�,''' � <r r.i.F '�r�. t r '�/ _ .,^''r "f'.f{/ r',,� r� r _ ,,' �� - f / .�`� ,. / r` I r r /r =`• r% rr /' '`!f 1d,,d! s- r r j`Jf_> ,iJ f' '''t J+` f r � ,,r ,,: �j s s` •'r,�- .r %r r+'�' j t''dr,' t r.+ .d',r f t 'x',r F ,' ;- .% _.' =r`, .'r "`r3'i,:' fr•j' -'r., F,r•J%`,< r' s'1r''"':' '` ,/r''. - ' rr,r r'' 'ram '' 1`•' .r'.,: ,`,•: ' t, 'r r`< . s'" !",f•�.i`ff,••�ter' /`s .,,r `/`.,i' ,J r - jrYj`f,/' /_ ,,e" r,srI' a•'•,- r°' " F r`i. d > 'f' ,'° f f / rf f %Y rt✓ r'` f��r,r"�Yr / Ir r - ,f �`d �f,Y o � ,�j' � `, _r ,,' r= ,, .ram, .` J,,� r =�• ONLY DRAWINGS STAMPED QY En ineerS PLLC �-•- r' .r � j � .< �� r / r r - f f � .'.F..'` :" ! , �r �{ 'f r r ,yrl" `f .r ,, � t r�r �' t �� JARRETT $` ' ` ' �` ' r' '�' ,'' ' °` `' ' `a,` rJ' WITH A RED ISSUED FOR CONSTRUCTION STAMP ARE TO BE CONSIDERED LEGAL,TRUE&VALID CONSTRUCTION DOCUMENTS V) }_ 03/30/09 AC REVISED FOR SEATING LAYOUT - ISSUED FOR PERMIT TO CONSTRUCT • 3 6 0 0 03/10/09 /B\ ISSUED FOR PERMIT TO CONSTRUCT �— 02/26/09 Lk, ISSUED FOR CLIENT REVIEW & USE a 0 v o o DATE REV # ISSUED / REVISIONS DRAWING: L� EATING LAYOUT SEAT BEER GARDEN SITE & BUILDINGRENOVATIONS THE GREAT ESCAPE & SPLASHWATER KINGDOM ROUTE 9 U ® ® ® QUEENSBURY, NEW YORK JARRETT- Engineers, PLLC Q Civil &a Environmental Engineering N f GRAPHIC SCALE 12 EAST WASHINGTON STREET PHONE: (518) 792-2907 i 7 t. 4 0 2 4 8 1 6 COPYRIGHT©2009 GLENS FALLS, N.Y. FAX: (518) 798-1864 41 •_ a�t r _.�_�._� ONLY COPIES OF THIS DRAWING D 7R A Fil BEER GARDEN SEATING LAYOUT BLUE SEAL SHALL BECONSfDEREDiRUE MARCH 2O09 PRO # 01-054.14 SHEET: 1 OF 1 IZ J 1 (IN FEET) ANDVAUD EILI w A Six Page TheM PW SCALE: SEE GRAPHIC SCALE ALTERATION OF THIS DOCUMENTE)CEPT —� BY LICENSED ENGINEER ISUNLAIAFUL. BASESHEEr: 22 X 34 PLOTTED/REASED:03/30/09 4:00 PM IL-j L� H OD I FORMATIO REVISIONS MAX. EXHAUST PLENUM SUPPLY PLENUM HOOD CONFIG. SCREW IN COMPACT DESCRIPTION DATE: HOOD RISERS) RISER(S) HOOD Changed Hoods TAG MODEL LENGTH C❑❑KING TOTAL TOTAL END T❑ FLUORESCENT BULB, 9 2-18-09 NO. TEMP, EXH. CFM WIDTH LENG. DIA. CFM S.P. SUP. CFM WIDTH LENG, DIA. CFM S.P. C❑NSTRUCTION END ROW 3.00' STANDARD INCANDESCENT © Per Revised Layout 6024 6' 0.00' 450 10, 12, 1350 -0.399' 430 SS 12.00' Changed Hoods LIGHT FIXTURE 34-09 Per Revised Layout - 4.00' Q 1 #23F 1350 1148 ALONE FRONT EXHAUST RISE (SEE HOOD OPTIONS TABLE) De FIELD WRAPPER 20.00' HIGH ND-2-PSP-SS g' Where Exposed 14.00' - _ 7224 8' 0.00, 450 10' 17' 1800 -0.436' 430 SS ATTACHING PLATES 2 #23B 1800 1520 ND-2-PSP-SS Deg' Where Exposed ALONE BACK Utility HANGING ANGLE SUPPLY RISER WITH 5424 13' 0.00' 14' 20' 3250 -0.644' 430 SS � Cabinet 2 75' OLUME DAMPER 3 #32 600 3250 2762 RIGHT ALONE 2D.Do' 00 23.57 OPEN STAINLESS ND-2-PSP-F Deg' Where Exposed 54.00' 16' SS BAFFLE WITH STEEL PERFORATED PANEL 6024 9' 0.00' 600 16' 24' 4050 -0.534' 304 SS U.L. Listed Screw In Compact Fluorescent Bulb HANDLES AND HO❑K 4 #90 NDI Deg. 4050 0 Where Exposed ALONE ALONE E 3.00' INTERNAL STANDOFF 6' O HOOD INFORMATION 16' 24.00 N❑M. FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE MOUNTED IN UTILITY CABINET1 CU HOOD FIRE SYSTEM ELECTRICAL SWITCHES HOOD WIRE SYSTEM ELECTRICAL CONTRAS I N NO. TYPE QTY.HEIGHT LENGTH QTY. TYPE GUARD L❑CATION TYPE SIZE MODEL # QUANTITY L❑CATION PIPING WEIGHT NOTEi Additional hanging angles provided for hoods longer than 12 ft. LIGHT SWITCH IT IS THE RESPONSIBILITY I 4- g g g P g FAN SWITCH OF THE ARCHITECT/OWNER TO ' CL 2 16' 16' Screw In Compact 390 Q ENSURE THAT THE HOOD CLEARANCE 1 SS Baffle with Handles 2 16' 20' 2 Fluore N❑ N❑ LBS FROM LIMITED-COMBUSTIBLE " U Screw In Compact 538 AND COMBUSTIBLE MATERIALS o 2 SS Baffle with Handles 4 16' 20' 3 NO NO 10,00• 10.00' 10.00• IS IN C❑MPLIANCE WITH Fluore LBS 16.00' LOCAL CODE REQUIREMENTS. I 7 16' 20, Screw In Compact Right 1 Light 908 0 B.oO' B.Oo' 8.00• o I 10. 3 SS Bnffle with Handles 4 NO g 32111002 ❑utside N❑ ® ®16 Fluore 1 Fnn LBS GREASE DRAIN6 16' 16' Screw In Compact 1 Light 453 24.00• 24.00' 24.00• WITH REMOVABLE CUPIII4 SS Baffle with Handles 6 16' 20' 6 Fluore NO Right 31011002 1 Fan ❑utside N❑ LBS 48.0' MAX III U 7B.00' I 78.00' 104 00, M) OPTIONS PERFORATED SUPPLY PLENU S I It RISER(S) I ' rn HOOD OPTION HOOD POS. LENGTH WIDTH HEIGHT 28.00, I 56.00' I 56.00' i 28.0 ' BACKSPLASH 80.00' HIGH B X 168.00' LONG W - N❑. N0. fl6s LENG. DIA. CFM S.P. 13' 0.00'Nom./13' 0.00'OD 12.00' 80.00' OFF MIN. Q 1 FIELD WRAPPER 20.00' High Front, Left, Right 1 Left 60' 12' 6' 28' S74 0.077' I I � � Right 60' 12' 6' 28' S74 0.077' PLAN VIEW - Hood #3 (#32� w2 FIELD WRAPPER 20.00' High Front, Left, Right, Back 2 Left 72' 12' 6' 26' 845 0.120' 13' 0.00" LONG 5424ND-2-PSP-F I UM o Right 57' 12' 6' 8' 26' 675 1 0.098' 0 aoch 3 Front 168' 16' 6' 10' 24' 920 0.152' FINISHED BACK - GR❑UND/P❑LISH 96.00' Long 10' 24' 920 0.152' EQUIPMENT J � SCREW IN COMPACT BY OTHERS Q 3 BACKSPLASH 80.00' High X 168,00' Long 430 SS 10' 24' 920 0.152' FLUORESCENT BULB, _ Z � STANDARD INCANDESCENT O M LIGHT FIXTURE FIELD WRAPPER 20.00' High Front, Left, Right 72.00' FIELD WRAPPER 20.00' HIGH xQ EXHAUST RISE CSEE HOOD ❑PTI❑NS TABLE) W '� 4 LEFT END STANDOFF(FIN/INS- ISLAND) V Wide Insulated ao HANGING ANGLE M N .0Lo 0' PERFORATED SUPPLY PLENUM - BOTH ENEDS O cV u7 16' SS BAFFLE WITH > HANDLES AND HOOK 7----, - - - - SECTION VIEW - MODEL 5424ND-2-PSP-F , 3 W W 3.00' INTERNAL STANDOFF 24.00 NOM. Z 0 60.00' I W a EXHAUST RISE SCREW IN COMPACT F rn IT IS THE RESPONSIBILITY FLUORESCENT BULB,STANDARD INCANDESCENT OF THE ARCHITECT/OWNER TO HANGING ANGLE LIGHT FIXTURE ~ `- ENSURE THAT THE HOOD CLEARANCE V� FROM LIMITED-COMBUSTIBLE 00' ? Z AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH 16' SS BAFFLE WITH PLAN VIEW - Hood #1 (#23FI LOCAL CODE REQUIREMENTS. HANDLES AND H❑OK 6' 0.00" LONG 6024ND-2-PSP-SS GREASE DRAIN Z 6' 0.00'Nom./6' 0.00'OD WITH REMOVABLE CUP 48.0 MAX 0 24.00 N❑M. o 10 00, f° 0 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO rn Tj 12.00' 12.00'-1 ENSURE THAT THE HOOD CLEARANCE � 78.00' OFF MIN. FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS co ® ® IS IN COMPLIANCE WITH 0 0 0 0 i LOCAL CODE REQUIREMENTS. EQUIPMENT WITH REMOVABLE GREASE RCUP AIN 30.00' r 30.00' BY OTHERS 48.0' MAX 104 00, nQ }ua3sauon» }oodmo0 uI Ma,4oS pa4.sl-1 G 8. 0 28.00 60.00' 80.00' OFF MIN. 30.00' I -� 30.00' 6.00' logo, 6.00• SECTION VIEW - MODEL 7224ND-2-PSP-SS EQUIPMENT F-PrZI 0 0 10.00' � 0 0 BY OTHERS 3.00 �0 �0 10.00, 10.00' Existing Column SCREW IN COMPACT U FLUORESCENT BULB, ln 36.00' 6.00' � IGHTAF FIXTURE RD INCANDESCENT W 17.00, 0.00, FIELD WRAPPER 20.00' HIGH 6.00' EXHAUST RISE (SEE HOOD ❑PTIONS TABLE) SECTION VIEW - MODEL 6024NDI 4--) GENERAL z NERAL NOTES : d nn '' HANGING ANGLE 1. ELECTRICAL HOOK-UP TO CAS MOTOR CONTROLS W (MOTOR STARTERS, FAN SWITCHES, 26.00' FAN DISCONNECTS, RELAYS, ETC. ) BY OTHERS. n 1 U.L. Listed Screw I Compact Fluorescent Bulb .00' PERFORATED SUPPLY PLENUM - BOTH ENEDS 2. FIRE CHASE BY OTHERS IF REQUIRED. 26.00' 16' SS BAFFLE WITH 3. ALL PHASES OF INSTALLATION SHALL COMPLY V VJ HANDLES AND HOOK----,, WITH NFPA 96. 4 OVER SCALE.MEASUREMENTS HAVE PRECEDENCE I n O 3.00' INTERNAL STANDOFF 5. PROVIDE CLEANOUTS IN EXHAUST AIR V 36.00 8.00H I - rn 24.00 N❑M. ® ® DUCTS AS INDICATED TO ALLOW CLEANING V J I � 28.00' 30.00' AT ALL 6. EXHAUSTBENDS DUCT TODBEOR16ZONTAL GA. GAVUSTEEL LD 8.00' ALL SEAMS AND JOINTS TO HAVE A LIQUID -� IT IS THE RESPONSIBILITY TIGHT CONTINUOUS EXTERNAL WELD. Ho 0 0 0 OF THE ARCHITECT/OWNER TO Utllty7. FAN T❑ HAVE A MINIMUM OF 10 FT. OF LL❑ ® ENSURE THAT THE HOOD CLEARANCE Cabinet CLEARANCE FROM THE OUTLET TO ADJACENT FROM LIMITED-COMBUSTIBLE Z1 BUILDINGS, PROPERTY LINES, AIR INTAKES -L AND COMBUSTIBLE MATERIALS r 60.001 16.00 OR 3 FT. VERTICAL CLEARANCE PER NFPA96 X 12.00' 12.00' 8. HORIZONTAL EXHAUST DUCT TO SLOPE NOT LESS LOCAL CODE REQUIREMENTS.IS IN COMPLIANCE WITH lJ THAN 1/4' PER FOOT TOWARD HOOD FOR DUCT I 48.00' 48.00' L MOUNTED IN UTILITY CABINETi LESS THAN 75' LONG. GREASE DRAIN ELECTRICAL CONTROLS 1' PER FOOT SLOPE FOR DUCT LONGER THAN 75' WITH REMOVABLE CUP 24.00•� µ CH 9 ONOALLO❑PENRSIDESC❑OKING EQUIPMENT 6' 48,0 MAX 10. EXHAUST DUCT TO BE PROTECTED FROM DATE: 3/4/2009 8' 0.00'Nom./8' 0.00'❑D 10200, ® U.L. Listed Screw In Compact Fluorescent Bulb ® COMBUSTIBLES PER NFPA96 AND LOCAL CODE. 11. BUILDING PRESSURE SHALL NOT EXCEED 0. 02' PLAN VIEW - Hood #2 (#23B) WATER COLUMN AT EXTERIOR DOORS. ■ DWG.#. WITH RESPECT TO THE DINING ROOM. 868918 8' 0.00" LONG 7224ND-2-PSP-SS . KITCHEN SHALL BE BALANCED TO BE NEGATIVE 78.00' OFF MIN. FOR QUESTIONS CALL THE: DRAWN 54.00' S4.o0• WESTERN do CENTRAL NY CAPTIVE-AIRE REGIONAL SALES OFFICE BY: R T G 1264 RIDGE ROAD, ONTARIO, NY 14519 EQUIPMENT PHONE: (315) 524-3861, (800) 774-3417 SCALE. FAX: (315) 524-3868 Not To Scale BY OTHERS 9' 0.00'Nom./9' 0.25'❑D poo• CAPTIVE-AIRE HOODS ARE BUILT IN C❑MPLIANCE WITH SUBMITTAL PLAN VIEW - Hood #4 (#901 9' 0.00" LONG 6024NDI NSF L J CUSTOMER APPROVAL TO MANUFACTURE1 NFPA Approved as Noted ❑ NFPA #96 - 2008 EDITION Approved with NO Exception Taken ❑ SECTION VIEW - MODEL 6024ND-2-PSP-SS ETL LISTED TO UL-710 REQUIREMENTS Revise and Resubmit ❑ IMC 2007 SHEET NO. SIGNATURE NYS Mechanical Code, 2007 1 Your Title Date SECTIONS 507, 508, & 509 EQUIPMENT SCHEDULE ............... ......... 1. WALK IN COOLER I COOLER I FREEZER (EXISTING RELOCATED) 49. BOOSTER HEATER(FUTURE) 2. COOLER EVAPORATOR COIL (EXISTING RELOCATED) 50. WALL SHELF 3. COOLER CONDENSING UNIT (EXISTING RELOCATED) 51. THREE COMPARTMENT POT SINK 4. FREEZER EVAPORATOR COIL (EXISTING RELOCATED) 52. FAUCET - 5. FREEZER CONDENSING UNIT (EXISTING RELOCATED) 53. FIRE SHUTTER (BY OTHERS) 6. COOLER EVAPORATOR COIL (EXISTING RELOCATED) 54. TRAY WASHER (FUTURE) 7. COOLER CONDENSING UNIT (EXISTING RELOCATED) 55. VENT DUCT AND FAN (FUTURE) 8. COOLER STORAGE SHELVING 56. UTILITY CART (BY OWNER) 9. FREEZER STORAGE SHELVING 57. HAND SINK 10. KEG SHELVING RACK 57.1. SOAP AND TOWEL DISPENSER (BY OWNER) 11. DRY STORAGE SHELVING 58. SPARE NUMBER 89• 12. MOP SINK 59. SPARE NUMBER60. COUNTER WITH SINK 13. CHEMICAL STORAGE SHELVING 61. FAUCET z 14. SLICER (EXISTING RELOCATED aaa =t ) 62. WORKTABLE = 15. ICE MAKER WITH BIN AND FILTER (EXISTING RELOCATED) 63, SERVING COUNTER 16. SODA SYSTEM(BY OTHERS A division of a 17. HAND SINK ) 64. DROP IN FROST TOP Buffalo Hotel Supply _ 18. WORKTABLE WITH SINK 65. DROP IN HEATED SHELF 66. DISPLAY CASE =a 86• 18.1. FAUCET 67. HEAT LAMP 375 Commerce Drive 2 19. WALL SHELF WITH POT RACK 67.1. DISPLAY LIGHTS z� 20. MOBILE PAN RACK 68. DROP IN HOT FOOD WELL Amherst, NY 14228 i a 21. MOBILE WORKTABLE 69. SODA AND ICE DISPENSER (BY OTHERS) (716) 691-8080 �? 22. CONVEYOR BROILER 70. REMOTE BEER SYSTEM(FUTURE) 23. EXHAUST HOOD WITH MAKE UP AIR 71. RECESSED DRAIN PAN FaX (716) 691-3255 89. 24. EXHAUST FAN 72. COLD PAN 9S 25. MAKE UP AIR SYSTEM AND DUCT 73. POS SYSTEM (BY OTHERS) 26. WORKTABLE WITH OVERSHELF 74. DROP IN FROST TOP Offices: 27. REFRIGERATED PREPARATION TABLE (BY OTHERS) 75. DROP IN HOT FOOD WELL H 28. PIZZA OVEN (BY OTHERS) 76. DISPLAY CASE 29. FRYER SYSTEM 77. HEAT LAMP Buffalo 30. CHARBROILER WITH STAND 1�\ 31. STEAMER WITH FILTER(EXISTING RELOCATED) 7 SODA 79.. RECESSED ICE DISPENSER (BY OTHERS) DRAIN PAN Rochester `� 32. EXHAUST HOOD WITH MAKE UP AIR EXHAUST FAN 81. CASHIER STAND Albany _ FIRE SUPPRESSIONS SYSTEM 82. CASHIER STAND SPARE NUMBER 83. TRIVET 36. SPARE NUMBER 84. WORK COUNTER WITH SINK 98 89. 85. FAUCET 37. WORKTABLE H Z ' z 38. WALL MOUNTED PASS SHELF 86. CONDINENT STAND Z Z 0 w o w g$ 38.1. DELETED 0w�w0z ¢Wu i z 87. REACH IN UNDERCOUNTER REFRIGERATOR w 3 < a z a z 88. MOBILE HEATED CABINETS (EXISTING RELOCATED) O =o w� 3 a -M�z 39. PASS THRU HEATED CABINET 89. NAPKIN DISPENSER (BY OTHERS) U m m a w �w w= 41. PASS THRU HEATEDPASS THRU NET 90. EXHAUST HOOD o Z JX w?_a O-m 3 C 5 Owo(nF' z Jcr z z z 91. EXHAUST FAN F a T Q'r-j 0} a z z 42. WORKTABLE 86. 43. COFFEE MAKER (BY OTHERS) 92. SPARE NUMBER a o v 0 3 a a 73. _ 2 ? 44. ICED TEA BREWER (BY OTHERS) 93. FIRE SUPPRESSION SYSTEM z 0 N z Uj�z Zo�� :a .a �_ 0 O z 46. HAND SINK �• PORTABLE GAS GRILL L�, z w 0 -UO o 3 w 0 J zza 45. WALL SHELF >o J0pi LUO i, 95. QUEING RAILS m a w w= 2 �:3 zza 96, CASHIER STAND U_ �JazZw0Ro=~a 46.1. SOAP AND TOWEL DISPENSER (BY OWNER) Z <_j -w a z w z 3 i 47. REACH IN FREEZER 97. DRY STORAGE SHELVING O o x j 0 0 z 0=3 0 48. REACH IN REFRIGERATOR 98. TRASH RECEPTACLES (BY OTHERS) U �w 0 v z j L _�m Aga 82. w ZF- aV�- za& 89 99. MOBILE KEG COOLER WITH TAP(FUTURE) o =0}o o�'a 0 73. CE azWmov)�2NQ=z WOE~ w oO OO cn�v►��M�Uoaz H REMOVABLE F--� _ BARRIERS \ \\` �;e 96. 72. 7 . �\ a ;.._ 00 ' 67.25. �T: I z:, : a a 95. Eli 9 vi 68. ' Z H r\ 57.1. �' I _'' a; I-) I ® I I owG a ......................... L__.,._ J L__,..__J 63. $ I I I I I I I a= I I I f41 9 col Z 17. I I I 67. a ----- ----�� - _- --- w 84 73 87 88 88 O J----J 65. I a; 1. II z2 N 1 as Z 47. I I I 66. ;= p o 99. I 11 az (!1 37. �. o 30. 29. I 38. I I 62. 67.1. a: ........•.-.-_-_-.•.-•-•... � M I 31. - I I :a I II Qa i-----i L---- ---------------------- 90. s I ---- -- a.:- - ------------------------ i -- = 93. --J 23. ------------- - 53. i I I I J 1 67.1. a: w -I-- a ................................... rn 50. ( : _ o m Of 0 _ _ r + 39. $i i I I ' _ I I I o 8: I 51. .. �\,_• ---- ----- ----- Q a 21. 22. I 7 � _ ; . . � I -- __ = . 13. =tea 97. M L----J 12 I _ ? ----- ----- I I r , _ I i QLd ; :- w Z \� I -------------- I I I I I jl i 76. I i I 3 2 I I I I JQ Q w O U 40. 0 a_ 75. I $ H O I.r■ : I 20. � 12. `� i I I 83. I ' LD 27. I e I I i + 41. L ji 0 cn 28. i ` 1 26. 15. 95. O rn m rn Z 2 = F- m O N O O - „ I II I I I j; a W �, ; �, L- -------------------- 23.1 J I----hI 78. 0 I1 I 43. I m W N (L c� N 42. I 'I I I Z) CL Q F5 i ;$ REMOVABLE 0 a 18.1. 19. 14. -- i "1 8 i BARRIERS `� z 18. I 60. Z2 � O Q 11. ---------- ----ram- ---r - 46. 45. I I I 70. & .�� r w Z :,: :,, ai w 79 -- ------ --- L----- st ' 88. --- -� 61- 73. 73. 73. + a ' ,a.�:\� , ,�, �a a a, �` •,� a�a +35 F ;fir` ,.,, �sa�„ 86. COOLER ,\��\\\\,\��.,� \�\, ,sa\;:�,�;\ ,��; \\\,\\z�,\1\.,.\\,� COOLER r;�z: 8L 96. 49. 55. 1189. ,_� tip.,.�� --z�r,��;M• 98. 54. 1 _a• 1. 8. ` T 10. ::�.:. ... 1 -�,.,•.�? I FREEZER 10. 2. • 4. 6. :- _Z�_-� 9. -- - g. 8. -- -- 55. •a ya,•�.;,� _• \ 'i a'\ \i:l`,a :A,, \7,,,, +: a •\+,+�4' a,\; `\,� i. ,'� 'y`,i, �`:\ i ` :3,\" i�;\7 i, `'1-�---�-�--- @ _U > `1 \\�1a C � ,1 :'y,v@E �c,.,.. ,�,�,,��;Z ;�`� :� � ,, `:,',;;�Z` a�,t`a;,,x��'i\ •�,�'•��', ,•,h •,��\, �, .��\\b',..>;�:3; �; _J _J _� _�/ ,*� a;• a•0,�;* :� �,;,\. i•i:a:�\ •;.aya�; .a:`,�,\;2` \_.�1\:i,i.i.,', "�,•' a�., \•• `:a;ay�,a.,4ti, Z Y as 5w O � � w 0 LL = N H Z W Y W a- 0 ? U) 000 H W H w W Q W Z) Z U w- m O � W C7 ~ Mtn QHm z wO = � tn OX � � W LL_n Q � C� v fn �1 DRAWING NUMBER: LL FSE 1 L LEGEND & NOTES SIMILAR CONST FOR SOFFIT �. 5/4" WOOD TREAD m CONTINUOUS WOOD CAP PLATE UNLESS OTHERWISE NOTED ALL INTERIOR DBL. 3-5/8" METAL 3/4" WOOD RISER PARTITIONS ARE TO BE 3 5/8" METAL 4TItt CAP PLATE WOOD STRINGER 5/8STUD GYP UM BOARD NON IG©N EACH AT 16- FACE. U UNLESS OTHERWISE INDICATED WALLS ARE `D T11SIGNAGE BY ®- TO EXTEND TO UNDERSIDE OF EXISTING. OTHERS ROOF FRAMING No. DESCRIPTION DATE CD a-1 REVISIONS D cn " O En �j FRAMING IS WWPA SPF#2 EXCEPT AS NOTED. ¢ 3-5/8 METAL 5 1/2" STUD WALL BETWEEN I STUD SOFFIT 750fb - 1,100,000E U) KITCHEN AND SERVING LINE o (HEIGHT VARIES} " » �� -INDICATES MEMBER, SIZE & SPACING. W o rn CD 8 BOX 11 1 1 8 NOSING r BEAM �zE INDICATES BEAM SIZE. F->- w C, Z a f 1 � = Z CU STAGE STAIR SECTION STAIRS,- ALL RISERS & TREADS TO BE EQUAL uW V o L o a CD 1/2"=1'-O" - STAIRS WITH MORE THAN 3 RISERS TO HAVE A HANDRAIL LLJ ~ a Z I (BOTH SIDES IF BOTH ARE OPEN) 2 Z a -' � o DOUBLE HUNG VINYL WINDOW — OPEN PLATFORMS OR PORCHES MORE THAN 30" A.F.F. OR A.F.G. o L, o I I UNIT WITH THERMAL BARRIER TO HAVE GUARDRAILS. 0 o N & INSULATING GLASS I Q o z I I cn 00 E ww � r r I I � 'o Ooa CD 5'-6" 5'-6" �,z �,o o o It 0" o c v, Qwl- a v w 1 I I O Z (D C Coop -jo — ``�� oz > ' 00 I I I VJ Q Q L Q a EXISITNG EXTERIOR 23/32" APA RATED ZjE 0-0 0 D N P I P WALL SHEATHING - GLUED U v o Q < I +I 100 - I & NAILED � a I o � �I 1 POINT OF SPRINKLER I SALES RISER WITH �/ o .� cv STAIRS BEYOND [C co w w � � I D° FIRE DEPT. R' 2x8 PLATFORM FRAMING (SEE SECTION THIS I 1 t wORAGE CONNECTION PAGE) i I r /- 2x4 STUD WALLS WORK IS TO BE AS SHOWN & iv FOR STAGE SUPPORT �y NOTED AND IN ACCORDANCE i It1" I I WITH MANUFACTURER'SLy CONCRETE PADU1 REFER TO 103 LINE OF FINISHED FLOUR RECOMMENDATIONS, TRADE o ASSOCIATION PUBLISHED o STRUCTURAL � 101 RECOMMENDATIONS AND 3_ _, �n ,x GENERALLY ACCEPTED LOCAL - SOFFIT DETAIL ^�S�'� 5�5� ' DRAWINGS FOR 12 6 CONSTRUC 2 -W� TA� SLAB v- Pts Icy, STAGE SECTION HUAC &-- ¢� PRACTICES. TfON INDUSTRY 1/2"=1'-0" A-1 A-1 INFORMATION) KITCHEN 1t,a WL �"^ 3-4 31'-3f" 20'-2j" =P - 6' 10" Q ash cv s '-3" 4-4 5'-2" 7'-7" 9'-0" 9'-3" I e 10 I - O -. -----------------.--------_ -- - _. - --.-------.------------- ._ -T L �"STUD oo 5 " to WALL 110 I I °j 6'-0" 2'-11" 104 h r RIDGE L— -- --- ---- -- -- -- ---- I rn I; 8' 3" I *0 co 3--I 01 L105 in N N u ' N In 3'— N N 10'-0" �./ O �I-# i i io 2x12 RAFTERS 2x12 RAFTERS I 'o ii - u co II ` ° -� � 7'-4�" i..i „ I 0 16" O.C. ® 16 O.C. I '� 4y� 2` H I DORMER RIDGE I'NN10 LINE OF o 8 BOX i \ �. Mom" SOFFIT M BEAM �5• ABOVE " " __ bb O 4'-4" 18'-6" 13-0 1 -1 In -n 11A-1 A-1 » o i STAGE W1 I t1A ERVING/DINING AREA o v>I 2x8 FLOORoA -2 co N �'-JOISTS ®-- t 7 1-14 VALLEY JACK CRIPPLE I 16" O.C. I w1 i I VALLEY RAFTER OUBLE HEADER I I L-———--——————---————————————————————————————————————————————— W.C. Q,) CAN ROOF FRAMING PLAN A r% c •��,, +��, �uFT A-1 A-2 A-1 A-2 `� SEE WHEELCiAIR LIFT DETAIL ON XXX 7'-4 " FOR ADDITIONAL '0 10'-0" INFORMATION cV , —.--_._ ------.------------- .---_.—_.—_...— ._-- --..------------------ --_.----.------- ————————— — r ————--——— 2, p» T'I r- r- I 2'-p» - �\ I CII I I LI R LI FOUNDATION o EXISTING FOUN + 1 1 I WALL AND FOOTING 0 o TO REMAIN. I - �❑�� � -'z�' >, I `' '� ABOVE I I` � �.�t,L.�� �S-tG�.�t,$. � , :� ''fi"z//f�ii>ril//•ii / .�,: I j I , N N I N I 11 0 2x12 RAFTERS 202 RAFTERS t 0 16 O.C. ® 16 O.C. DBL. 11 7/8 r LVL BEAM I CAD FILE NAME I I I DBL, 11 7/8' CONT. I ACAD\JAR—MAR\GREAT\BEER\C©NST. .a r 2-0 I I LVL BEAM » » " I I POST j I _ v b y e " SCALE , n -- , -- ---, CONT. . 1/8 =1 -0 _—I I _ —I I - —; r I _ ABo ,_ I 1 I 1 I I 1 1 I , DRAWN BY � i I I a 0 Q. e�- f E DRAWING TITLE 18'-2f" 14'-6" 15'-8 33'-0" 33'-0"18—2 4-6» _ FLOOR PLANS — 1 -- _. _--u --... - - _-._._.-.._-. --- ----.._ -_---. ---__...-_._ -- --,.-_--__--- -------------------------------------------------------- � AND - 16 INTERIOR CANOPY FOUNDATION PLAN BUILDING PLAN u��. s> ,��� �, ELEVATIONS 14 -'Pv` '< DRAWING No. A_1 aEMOR WALL V SUPPLY FROM SPRRNOER SYSTEM ZONE FASTEN SECURELY TO WALL 1'GLOBE VALVE (NORMALLY OPEN—OMIT FOR WET SYSTEM) 4" DRY PIPE VALVE MI MINIDRUMMUM LIINP LEG MIMMIMt 1z'LENGTH «« W/ TRIM«.. ,.. .«._«_« ««««« «1 c�M�R"Er DRUM DRIP AT U T T c 2t, z�, 0 TESTDATA AU-�i.iA-Y DRAW — +° N 0 ACCELERATORS 0-6 �,4-ilk{ �' TCR FIRE,. r' - s{ .� I s�a:ts �.# n. • x � r` �';�I«,_""�<<E 5 � �si..a<.r3?E�u:aF �:, sK•; i S st .«....................:�: ...,,. ....... .....«.._ .:;;........ ...5 �q r"3.S_VATKyii ✓1/C Yl{71i S3ff14 Ff^ !�, !3•-l5 4 4_6 L t'GLOBE VALVE 15_ :s,' . ( ? ) - a tt c'Isre. t�3ZZ£(i) ' sa 6t7 1 WATER MOTOR GONT WITH s r« � o g ;E " ' R� t GALVANIZED 0SEAL OPEMIG MITH E E 1 E d I _.x $.% % 1 ra E " ; DEGREE ELBOW Z ,� 1 ;ssas m tf 4 GROOVED CHECK GROUT TCHEE L �' tlit011E ESCUmEON ON >ATE ! INSIDE OF WALL I VALVE W/ ABD ' RMGGTI BORE LET W17H F RESISTANT ounEr rNTN FLAW Era •=f1 EQUAL m are sPRNatLER MIN sEAt ESglR?eON m ? o r? / ` WALL NI1N CONTINUOUS tf� In x' L j c THY• 3?ffizLt FSi ff7 SLAALLEST ORIFICE (OMIT WHEN SEALANT FILLET ^' I %i E LA 1 ` L' E r.:.;.;,., F1FCr G3#£FT1L SS'a fflt' 3'r# ONLY AUIa.lAR7 DRAIN I s o -.. • ';; . L:Z,ArK 4FLOOR IE 2$ i--fl�""� Q"slEz�f'a.'�'•3',4>.. P,Yf ' t o t 1 ,t TO SYSTEM g t ! s » 1' i \ o ��o t?o �r Ei o 't 5 S_TOR_Z_ FIRE DEPARTMENT ' i � '� $ I �! t :$ CONNECTION { E 4'-11 " 7t-7" 6'-7" 4' 4 '� i ol € :> LINE IN COOLERt .S 1 t l i t O �E o { __ ^ s t; { J $ 1 + l 0 _ 't i/ R f :t 3 / r k f E / h...... h-.,: s - , * its .«. ' *..."......., "" « —__"�. «.««.... .._.... _ ««.,«...«.... «..... :.... «««.-..._._.... 4 FEBCO DOUBLE CHECK f A �g 3_ $-- "'o fl i SPRIG� i7r3'1� 1Jf NI,� i,�.�fu'�i.E�J �I \ .._« + � •'�•'.4", BACKFLOW PREVENTER 4' 4, '; 4• 4• . ' - �, • '3' ° 38 3• 3' 3' 3-3 7-0 9�0 1-94-9 0-10 5- 0 gip \ 0-6 f'./ J Ji •:i:+ / 4 4 \ d" dd «� ifS,"E i� i 1 • i:EB�aE£3 �, $ $ a .--5 t� } r ks'� _r I .-r 1 .--t ;I mil -> .-••i SI , sa •,-.3 r t 3" I " p-6 / —Ott �n {E I 3 r ..... _ «". :: .......... �//lllIF— DRY r « SPRINKLER SYSTEMNO F; NOTES--•-/ BASE MOUNTED _ I% __ tf%f,: .i/iJv� f %r�s✓Jl°1.YyJS c ii —g f 12 �>9 r ~ AIR COMPRESSOR ' i _! Ln f .,~ sd�'X. t suf.•F�T ��I :rs��a/�`� t �Jrasr ;..".. :."'".".\'• Ai.l 1 t 4 y � .—. � .--t .--� i I ^ GALLONS , r-+ mm-5 '•.1L r3i :'sY...D '.Ay t6 I DRY SYSTEM CAPACITY: 250 L AL�.ON� � I 1 $sE 3.10 CU. i i/EL IN 40 PSI Ll PITCH MAINS '�' l.. 1 �• E�? 10 FT PITCH LINES NOT LESS THAN 1 32:t PER 10 F IID 0 fZ C.S y ._,.r., �.,r,., !�^,, :A H I t )Y Yy:.{••; _.l AR i`•>•�/.,Yt r ly+�`/' Q ES�SS1➢�)J� 'y� / � � iz,-,,,'; M .. .1..`� ......... J ,t.,>S.J'J I.�-I} Lr:./�,J' !,i ss+J..,2 I f,✓ «•./ , C /I I 15 S I E M � J VU :f � +6/ � '/ / /•;� .-i � .,�y '� Q, �' SERVICE � w _ 4 � s•— s NEE W 2 ; ,._., moalp f� — _ « «°cam 1�,, __ _ e s rf ,.;�{€ 4s ) j .— ft 5j V) H `s-,r$ '.. t ••`; �: g _ $ice sa ,•zE �p V tl a"l to C 1.,.„ f"'i Tll I�e REQUIRED Z S ^,,..,.. ............. "--"'-. t s_ 3 O `""� O (D m 0' ,AL I T « _�_ � `�� x� \ �O �%O X � f s k t « « "« // I I a3f 1 $ I .-r .--i I JP / S I 0 0 0 0. ON bi t " t M t " t tt t n t " t " 1 " I " t " t " t " ; t " ----------------- 7—0 4—6 4—6 7—0 4—6 - 4—6 7—0 4—6 4—6 7—0 4—6 4—6 ;;;7—0 y IIANGER DETAILS I I I I I 1 I yr { 1 at 1 I ty' � � i .� .� .-r .-. o .—t .-r --� o s>�f1 •—� ?• --+ o s: I a� � $s,i ¢ \ M C'7 3 \ C'7 f•7 ._.s f'7 a C`7 I \ C'') ;��'�—� C7 ,,, �'•` ! (h S„ti fT «' $� r+ 1 .--y LT .--i � LT af.' LT L _S .--i dE ••°�}<.......\ .1 .......CL CD IAZJ IVN f •-f r EE 4 t>r^ iN I � � yf� � �•- fL' 3�3 „:.S, i„J{.f s,�•.{ s./',-•S,;'',5,.: E �r S ea ` .� I .-r 1 .� I .-r I ti----� a .r I S6 1 .--� I _.,i I .-+ I •--i 1 i E �' 3- /I r :'.i S` ,.. y'+ JQ Rim 3 3EastL ?:� qq q "", "`" fi^"" 3�'" 3• 3% 3• '" 3' 3• -5 3• 3• a• 3 3• 3• 3• 4 "' y ,""""" a {^ 2_2 7-0 2-9 1 y.(� 1-0 2-9 7-0 �4 2-2 — ` — 0_6 0-6 qq/ i]/'��/ „*'",,,,, :•F S{ � ' E A�{4,.. '•� S' \ O T- Lf7 2• f. /.� �t 7 i Wa ! f / i3.__s f l S•• y .,., 0 •d•........................................«....«««.«««............•.........«, .... ...«; f...««-.,.«._.�... ««....... ......,.««.«._"«".""""..... .........3.........«��:::::::.. ,vn. ""...«.. ..««.. : HYDRAULIC SYSTEM ..................................................... ....... ........�L"�L..... .,--------..........F.. -•`--_...,.,,,.,....,......,...�:.. ....,,,,,,,.......-..-.--�--. -..---.............,...-.-.,.,,, ,.,,,,,,, ........ ..-..,, . ,YI�RA.�LIC — .a�f'�,rT�l`�I• ,.,................ .....t.............,..,,_.. - "................-.....,.,.,.,.. „ ifs .«««««......".....«_..««««__........,_..,•.,.,.,..""_«.... , 1' P AT BOTTOM �' " s i 1 L I�z 1 `( DRAIN ____ ,3,�,`y, I E ;-7 �� E,• ;9 r �� T?-ily...,BE.BUILDING PROTECTED CTED - IS P T' �qqq • /q'� ``' ; JQ P'r:' OTOI ....f.,.. ... : I 1 • �2 ,4'jv— <.,DRUM DRI ES' A I '�al~:slI IGA="s v_ $ r°' / i -•�. �" '•�",,,, s;� s ,.., .'; $ E �a• �aD '•. �C{r��I �ryEp�{}/ ,� ,�.��y,..., q / pJ. / s "a fE 4imvS ��i�.•--�--'Y S • /.L S,% -two;,,..` D�•✓3 V,eE=. CSEF KLER 1 . , � s s �. S f t 3 sE *- :-=r" % ""-"-«.�-_."_„" "-"-- l«.�CA I�}�, R» CeT», Irfi- 7 .. Z. S .1 1 E DINING AREA , „ ''••.. E : „ $ / "•,,,,,,., r•,r.�.}/•-'f( 3 {------.".-."««««.«., 1 / '! -• f' t' +� E s N O. O'�' •`S P R I N K E..Iri3'�S 'Y ( s m E H « a.. / i Efs�s S i i 4 S s 1 ti «""_"""" f yy DESIGN f --------- 1 BASIS O D E I G r % $ 1 �f a E .1 l h' RATIV,v 3 AB I=i, - ____` ` , { _ ''�. HEAD LAYOUT BASED ON �.x��s�.� S E STREAMS DISCHARGE I , , s € i FLAGS E { % ,�' a :�NaTRi3;,TIJN ` I��l CEILING BELOW .......................... I E BY SIX ,,: t G a i I E TOE E KEEP ; E Iv IN �a t H „- } L_ ,.;.,. «. s..., s f s FROM' _ 2. OUT<iED� r�C i S AWAY�f A f i! M •.J I I b.y`tJ, :«-------------------5 r i f 4 R I _% 5.....«....s f 5 5 s I DEFLECTORS 6 w_ ;..".«s...«�««L«« «_.�«_..._....s...«°................... SAFETY ��� �I�� €........__.::.'........., ,----- .--,--.««««« SYSTEMDEMAND i, GPM DISCHARGE f_.. -.._ ..... ...... ___.,. .....- -...._. ................ E - ...... ....- -_.. i t t .,-.. .,. i I f, E i I;",_...«."«««« 2, RESIDUAL PRESSURE —« $ AT YES» Ia E OF THE s t; E s i : i; Pa+: F�ESER s' i : I is E .�?j 5 s 3 s s s : / EE s 5 s: 5 f , t t 1S t S , "s , , , ;S / S • FOR CONSTRUCTION ONLY t ............ ,....t fr.. f.-„_ ....... ...._.. s. s Al 4/0 7/0 9 t ' ' `t ' s •• i " s $ / / E J ......•.•.•.•-•,,,,,,,,,,,,,,,,,,,,,,•.-,-,,,,,,,,,,,.-«,.,.,,,,...,,.,.,.,,,,.........•.........,...,....,,,,,,.,,,,-,-,.,,.,.•„•,,,.,,,,.,...,.,,.,.,-,..,.,,.,...,,,,,,,.,..,,.,.,-.............,.,.•.,.,.,,.,...,._,,._•-__,,,,.,,,,,.,.,,.,,,,,,,,-,.,,,....-.,,.,,,...,.,.,........•-.•.•......,,..,,....,,......-.,-,,,_.,.,,.,.,,,,,,,,.,.,.,,,,,.,--..,...,.......,..,,,........•.,..•.,.............,,.,,,,........ -,.,.,.,....•.,,-,.,........f...�.,,,.........•...... / -"/ Z2� REVISED REMOTE AREA ��� Ty FIRE CONTROL SYSTEMS INC. ' 4/3/09 REVISED WATER INFORMATION 104 REYNOLDS ROAD FORT EDWARD, NY 12828 SPRINKLER DESIGN CRITERIA PIPE & FITTINGS SUMMARY SPRINKLER LEGEND THE GREAT ESCAPE SIX FLAGS REMOTE AREA NO. / DENSITY REMOTE AREA HOSE ALLOW. SPKR. TEMP. MAX. SPAC'G MAIN MAINS TYPE SIZES PIPE ENDS FITTINGS SYMBOL MODEL & DESCRIPTION SIN ORIFICE K—FACTOR FINISH TEMP QUANTITY RENOVATIONS TO THE BEER GARDENS OCCUPANCY / DESIGN (GPM/SQ. FT.) (SQ. FT.) (GPM) (DEG.) (SQ. FT.) X LINE BLACK STEEL SCH 10 & 40 0 O VICTAULIC QR UPRIGHT V2704 1/2 5.60 BRASS 155 92 LAKE GEORGE, NEW YORK SPKR X FEED SCH-10 BLK 2 THRU 6 ROLL GRV BE VIC FIRELOCK REMOTE AREA #1 DINING 10 2535 100 155 225 OUTLETS TO BE ALLIED TYPE T3UF WELDED X BRANCHLET w/ FEMALE THREAD X CROSS SCH-10 BLK 2 THRU 6 ROLL GRV BE VIC FIRELOCK SCALE: DATE: AUTOMATIC X MAIN BLACK STEEL SCH 10 SPRINKLERS LINE X LINES SCH-40 BLK 1 THRU 2 THREAD BE STD BCI THD'D 1/8" = V-0" 3/28/09 OUTLETS TO BE ALLIED TYPE 3RG WELDED DRAWN BY: DRWG. NO. BRANCHLET w/ GROOVE X LINES SCH-10 BLK 1 THRU 2 ROLL GRV BE VIC FIRELOCK DRY PIPE SYSTEM WELDING SHALL CONFORM TO NFPA 13 '02 ED. TOTAL 92 CJC. FP-1 OF 1 N FPA- 13 2002