CO-0137-2018 TOWN OF �QU.EENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (5.18)761-8201 - -- Community Development-Building& Codes- (518) 761-8256 CERTIFICATE OF OCCUPANCY,. Permit Number C070137-2018: . Date Issued: Thursday, September 27, 2018 This is to certify that work requested to-be done as shown by Permit Number CO-0.137-2018 has been completed. Tax Map Number: 296.13-1-22:1 Location: 989 State Rte 9 Owner:' Tania Sharlow, 697 UPPER.GLEN STREET, LLC Applicant: Tania Sharlow This structure maybe occupied as a: Cerdficateof.OccupancyOnly Tenant: Birch Bark Eats By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the n property owner of the responsibility for compliance with Site Plan, . Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. } TOWN OF .QUEENSBURY .742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: CO-0137-2018- Tax Map No: 296.13-1-22.1 Permission is hereby granted to:. Birch Bark Eats For property located at: 989 State Rte 9 In the Town of Queensbury,to constructor place at the.above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform-. Building Codes and the Queensbury.Zoning Ordinance . Type of Construction Owner Name:. Tana Sharlow Certificate of occupancy $0:00 OwmerAddress: 149 ELMHURST DR Total Value $0:00 Queensbury,NY 12804 Contractor or.Builder's Name/Address Electrical Inspection Agency Plans&Specifications $ 100.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, September 27,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the So f Quee bury. /' k8vplemb er 27,2018 SIGNED-BY: �dfor the Town of Queensbury. Director of Building&Code Enforcement ^` CERTIFICATE OF OCCUPANCY ONLY office use only APPLICATION Permit#: _ CO - 0.1�'�-•2Q►�3 Toy+n of(jtrccnsbun Permit Fee:$ )OC) 742 Bay Road,Queensbury,NY 12804 Invoice#:. 2�J P:518-761-8206 or 518-761-8205 www.gueensbury.net P x Deb'c aus ly ID "This application-is for occupancy o 1 AUR='r g a building permit" CONTACT INFORMATION: APR 0 2 201� • Applicant: TOWN OF QUEENSBURY Name(s BUILDING&CODES Mailing Address, C/S/Z: 1 2\,w+rwrs��c��i Qoeens ha`� �C�-1 Cell Phone: ( 51 S . )-i q y--7 0 k1 V Land Line: Email: bir�nha.�rl�-e4�rS Q Q rY1o�< < .C QMA • Business Owner(s): Contact Name(s): a. o•�� Mailing Address, C/S/Z: 149 \w.h�rrsl; 17r'.yt QV2�nSb u t31-\ a-W Cell Phone: _( S%!S ) luy- 7045Z Land Line: _( ) Email: hircanho,c�eo.* o�t �\ . r, • Manager: C- Contact Name(s): �O-u•�00. J�Ov�� � Mailing Address, C/S/Z: Q ueev\s2,�l k-mo-I Cell Phone:_( 1�t%_) Land Liner _( ) Email: VDIct)f honk &-dS - GyyjW\. CAwvi • Property Owner(s): Business Name: (e?q-7 V4,arr 61 e 01 4rpetf L k CG Contact Name(s): - 'kc\r4. n 0.C,�--�� 91�n o 1Zerti� �l Mailing Address, C/S/Z: QVP-eSCI'sw Cell Phone: -( !S Land Line: _( ) Email: Contact Person for Building & Code Compliance: :1 2,► -a Sr'o.n\w%D Cell Phone: 5l fr ) Iuu .1 o u k Land Line: ( ) Email: Certificate of occupancy Only Revised December 2017 ' 296.13-1-22.1 CO-0137-2018 Birch Bark Eats 989 State Route 9 Certificate of Occupancy Only 742 Bay Road,Queensbury,NY 12804 tTOWN E "P:518-761-8206 or 518-761-8205 www.gueensbury.net APR o Z 2018BUSINESS INFORMATION: OFQUEENSBURYILDING&CODES Name of business: ��i rCYl Address (including suite, space; etc.): 9g°1 Sk 2t �Jk Type of business (i.e.: retail, car repair, etc.): �'00y) C9— Please provide an accurate layout of your store showing all walls, exits, stockrooms, rest rooms, counters and fixtures on a separate sheet of paper. IMPORANT: The business owner is responsible for keeping exits clear and maintaining exit signs and emergency lights.. Fire extinguishers, fire sprinkler systems, and fire alarm systems require annual inspections by an outside contractor and the corresponding documentation must be provided to the Town of Queensbury Fire Marshal's office. Fire extinguishing systems found in kitchens and gas stations require semi-annual inspections. Any violations noted - during an inspection require immediate corrective action and_a re-inspection. Applicant name: Applicant signatu LAI Date: 31�1 1 , Certificate of Occupancy Only Revised December 2017 '= 296.13-1-22.1 CO-0137-2018 Birch. Bark Eats --�- 989 State Route 9 ECEUV fn,n of(Lccnsbun ! Certificate of Occupancy Only L�NG APR 0 2 2010 742 Bay Road,Queensbury,NY 12804 BUILDI P:518-761-8206 or 518=761-8205 www.gueensbury.net TOWN OF &ECOD CODES EMERGENCY, CONTACT INFORMATION **THIS FORM IS USED TO ASSIST EMERGENCY SERVICE PERSONNEL WHO MAY BE CALLED TO YOUR BUSINESS AFTER HOURS. PLEASE BE SURE THE CONTACTS LISTED BELOW ARE WILLING AND AVAILABLE TO REPSOND DURING OFF-HOURS TO ASSIST POLICE AND/OR FIRE PERSONNEL IN GAINING ENTRY TO YOUR BUILDING.** PLEASE BE ADVISED THAT FAILURE TO ASSIST EMERGENCY SERVICE PERSONNEL MAY RESULT IN DAMAGE TO YOUR-BUILDING BY POLICE AND/OR FIRE PERSONNEL. Date: 3I2-1 kg Business,Name: '13it eve —7-:)0' � Business Location (including suite, space,etc.): ��� �� Q (�✓Qe'nsbz Y!4 Business Phone#: J-j{x�� 1 L%q - 1 DLA T 1. Contactname: kC5�►6, S"rnn\01,11 Main Phone:_( 5kk ) 'lNy - -1oL4 d ; Secondary Phone:_( ) Coming from what town/village? ��22�nSb�H 2. Contact name: ► 7)gvyv�n Main Phone:_( q0 b5SLp ;Secondary Phone:_( ) Coming from what town/village? VA h TOWN OF QUEENSBURY FIRE MARSHAL'S OFFICE P: 518-761-8206 F: 518-745-4437 FIREMARSHAL@QUEENSBURY.NET FIRE MARSHAL MIKE PALMER DEPUTY FIRE MARSHAL GARY STILLMAN Certificate of Occupancy Only Revised December 2017 FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road,.Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW, Birch Bark Eats 989 State Route 9 CC-000137-2018 4/2/2018 The following comments are based on review of the submitted plans: 1) Locks../ latches shall comply with chapter- 10 of the 2015 International Fire Code. 2) -NO Exit/Emergency light plan provided,.may require additional Exit signs or emergency lights. 3) Verify Fire Extinguisher locations . 4) Carbon monoxide detection is required. NOTE: combination smoke/CO alarms not allowed per NYS part 1228.4 (MUST BE PLUGIN WITH BATTERY BACKUP OR BATTERY ONLY WITH A TEN YEAR BATTERY OR PART OF FIRE ALARM SYSTEM) 5) Provide new key to the space for the Knox Box. 6) Based on plan provided a hood and suppression system may be r uired, additional info needed on.-cooking appliances.. Deputy Fire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 7618205 garys@queensbury.net Fire Marshal 's Office Phone: 518-761-8206 Fax: 518-745-4437 fiiremarshal fteensbunj net zvzvzv.queensburj.net 1P F FA M1 296.13-1-22.1 ft -:2- CO-0137-2018 00 Birch Bark Eats Cn 989 State Route 9 Certificate of Occupancy Only I , I I D - WE i a j. W WFEFENCES APR 02 2018' bsa� MAryOFUlAmS OF KN/GHr30FGGENSFALL$ING ' LAST SEO:MAMAY II i88]� � •' � i W�����o , BY.'000GIm SMcCORA]ACX G/� (� MAP OFAIISU,,RVEYMADE FOR ®YtlI V aY Ls:UESNSBUI\Y. . FRANRPARILLO • n n n u n a D"7ED:D.ECSJ:Ea29,2005 BUILDING&CODES Q m m m REv1 JUN aB,2009 BY.•VANSEN S'STEVES 9 I \ LANDS N/F OF r FRANK P.0 1491%1A61 470 \LNG \ BBB•¢ ^^'7 I I 1 V v io:1z o Uj S I I~ � � ./` 1 -V1 III 1 'Y, cMnm sroxe- \ � - I • �' . .'• / - REV! O 2. 1 1 1 q 43,686 S r SD..FT. \. 'I ..r�.:. , _..�i.. _.1.:�•..rv. .:.,...1 .. _...- -_- . .. -- -�S — ` ts.1 SB1 Or,E..' � nenY'i.."- •v.�.�r��.- k-.:�`1._...r.,_..'�ti 4 . .. BEv;sED Gor 1 .`\`— ., v,. �� yJ-•^a'\ tKs.4.�41� i �y s\ 143<t y -\, \ �_'�'� ali (�1 66�Rj(I - '�" ' .. I - 1f2,385.60 50..FT. 2.68 ACRES \ B1�• p0 - w r\ °'� X\j j F\ i�' e.�s I I-.. Ln 475 < oN Iow, ` 1 O ,am9 I wop� \e ,prr IV 1 , \µJI4�, �t -_--__., -� .46676_ \ \\ I\ 1 (c1WMi971.6 11 _� �'n ' N�- I ' � i m I \v-.1a.zti ;4 •D��LANENTERFDS N/F:OF •; ry ,: 4-) TURNF U1 ._ RISES,INC. MN &:GRAND-LAND.LLC rt PGor Rg, PIA�,--:—_ 'LEGEND' -0137-2018 296.13-1-22.1 CO O CIRF-CAP➢EDIRONRODFOUND' O'IRF-IfRf{{ppWN FOUND - - O IRS-I$ONM OLE MBESET t A 1W.�ILITY tF VERTICAL DATUM:NGVOBB Birch Bark Eats ® 5,4NRARYMANNOIE. CONTOUR INTERVAL=1 FOOT " K°° T BABIN 989 State Route 9 fIDR CONDIDONMO UNIT . vim- 4YOODFENCE Onl CNAWL/M(FENCE. -� BP�E Certificate of Occupancy y 1�f 1 ._ i IAffI10Pf .. _ 2g6.13-1-22 .. 8 7 6 5 4 3 2 BOM Table LWn Print provided as required by the Authority Having Jurisdiction. REVISIONS ITEM Flow QTY. PART NO DESCRIPTION SEE Fuel color IF THIS DRAWING NO. Points NOTE Type Mounting Zones for Nozzles ORIGINATED FROM ZONE REV. DESCRIPTION DATE INITIALS 1727in Wide x48in Deep x24in High Wall Gage pone of Nozzle(Max coverage not Shown) \` HEISER LOGISTICS fT WILL \\L 1 1 72x48x24 Hood Canopy Hood with 12x14 Duct(s) -ming Area. am Nozzle to center of Target \ CONTAIN A RAISED A Released to Customer 6/7/2018 SEM Cable Conduit pTexll AURANT SEAL IN THIS AREA 2 2 1 NL2D Wet Nozzle Dual Flow 2 Pipe for wet chemical i1w FIRE SUPPRESSION 3 1 MCH2 Mechanical Control Head 4 1 RPSM Remote Mechanical Pull Station 5 Q Revision Symbol. Refer to respective Revision for more information. location of symbol indicates area of cha a SYSTEM k= F 5 5 90KBS Comer Pulley 6 u` F 6 2 349H Link Housing Bracket 5 A 7 2 AR Fusible Link "ML" _ Y 8 10 1 L3000 3.0 Gallon Cylinder 7 9 1 MB15 Cylinder Mounting Bracket ` � cs '` 14 x" 10 1 AR Strobe Light and Horn 7 2 BREAK IN VIEW NOT SHOWN 11 1 AR 0.75in Mechanical Gas Valve 6 12 1 1 N L 1 H Wet Nozzle Single Flow 2 9 7 m y 13 2 AR Compression Seal 6 = ' 14 1 AR Compression Seal 5 16 1 24W 4 Burner Range Approx. Cooking Area 24Wx24D 8 Gas 13 12 Mount nozzle in center of surface 17 1 only and aim directly down only. Max Protection Area 28x28in 8 OF Nozzle height 34 to 48in above cooking surface. (Green Area) E 18 2 1 NL21- Wet Nozzle Dual Flow 2 Approximate Cooking Area f { E 19 1 16W Fryer with Drip Board 8 Gas 15Wx21 D Anywhere over Cooking Area. Aim at center of Cooking surface. Max Cooking Area: 500in 2 1 Nozzle Height 24 to 48in above Longest Cooking Side: 27.75in, 8 Cooking Surface. Longest Side of Vat: 18.0in 21 2 1 NL2H Wet Nozzle Dual Flow 2 Steel or tempered glass baffle plate is installed at a minimum of 8" in 17 y height between the fryer and 22 1 surface flames of adjacent - appliance. If at different heights hall be measured from the higher of 20 IS the two. E D D i a I i tI I See Notes 2 thru 2.3 for piping and 5 thru 5.2 for manual pull station As per installer system 1 h p includes horn/strobe. Una 5 F. , , f .. C 10 ,r 22 3 8 a Flow Points 3 9 18 17 Available Notes: 21 20 4 1 -System installation shall conform to requirements of: 1.1 NFPA 17A (Pre-engineered Wet Chemical Systems. 6 B 1.2 NFPA 96 (Ventilation Control and Fire Protection o Commercial Cooking Operations). 1.3 NFPA 72 (National Fire Alarm Code). y 1.4 All applicable state, local codes and authorities having jurisdiction. 16 '0019 B 2-For more detailed information please refer to the Protex II Technical Manual on the folowing: 2.1 Piping allowances please refer to Chapter 3. _ 2.2 Nozzle positions,aiming and maximum coverages refer to Chapter 3. 2.3 Hood and duct coverage maximums and nozzle models refer to Chapter 3. 2.3.1 1 st hood nozzle tore located 0 to 6"from edge of hood- Maximum coverage per node= lorl x 4'W. 2.3.2 Duct nozzle to be centered in duct at 0 to 6"into opening and aimed at center of duct. 11 • 2.3.3 Duct nozzles may be modularized to protect oversized ducts. 2.4 Only equipment referenced in the Protex II Technical Manual or alternate suppliers components that are fisted for use with the specific extinguishing system shall be used. 3-System drawing created based on information provided to Heiser Logistics. 3.1 Pipe routings, manual pull station and gas valve locations are not drawn to as installed specification and are shown for reference only. 3.2 Air handling equipment shall be deemed to be adequate by the authority having jurisdiction. 3.3 This plan has been produced by a person who is trained and substantially satisfies NFPA 17A, 2017 edition , sections 6.1, 6.1.1, 6.2, 6.3, 6.3.1,6.3.2, 6.3.3, 6.3.4. 4-A fire extinguisher with a minimum rating of Class K must be installed within the vicinity of the cooking ON in accordance with NFPA 10. A 5-Manual pull station requirements: 5.1 -Locate in the path of egress from hazard area. }� 5.2-Mount at height no more than 49'and no less than 42"from the floor. 7 I I ® j3 g � /f A 6-Quantity shown is for reference only and AR=As Required. Individual items may be � purchased as packaged kits or are available for purchase separately. 3 6 9 (in) Call Heiser Logistics for details 1-800-828-9638. ►l aaac.' s tls ia..,t a�eifatik an an'as d loss,usiq iJawrtim a.WW 7-Tank(s) located from hood. Distance supplied by Installer. IOR,andasae�tlPw 0on=ls.ar►. You*AUM ,�,,.,,d cbffWS ,.,,,,WWW INSTALLER: DESCRIPTION inatn,ctiona,as - d*=Cedes and it w/a.n�tion a tlr use and NAME DATE F ANY COtAMION$IECESSRAIE SULUAWL4 CHANGE FROM APPROVED PLAN,AS 8-When required to modularize protection for oversized appliances please refer to Protex 11 Technical Manual Chapter 3. " T�� � = R$aMD U Protect-It Fire Services MALLEDPLANSSHAILBESUBMRfMTO THE AUIHORIIYHAVN(;J1RISpICTIpN 1 2 3 (Ft) a..��M„T__ . ANOl1'm �Ta � Birch Bak East DRAWN SEM 6/7/2018 DWG. NO. REV YHE nE wL®wMnwrts os Maiowrr�eanY. ems.-mot• CHECKED 101975 9- Field verification of the maximum ambient temperature must occur prior to selecting fusible ink temperdwe(s). "�* ANO1" v °'T p adme;aa m n,. a/eRdr aauracy of eaarwwt Ylr woaiw a.d atl users ar tli DRAWING PREPARED BY HEISER LOGISTICS Rte 9 Queensbury, NY ENG APPR. errs and hold h.n,re:rs...r la�ea,l<tl alioe,s,ay.saa and - , , Pnn CCI(e per"`,.. a�a�a.d �, � ,� 35 North St,Suite so,CANANDAIGUA,NY 14424 SHEET 1 OF 1 -...:.. �argiy aK�R n,l�gp OD.tlr!Yet ar nliw0f apes Ili decwrrerK. .,..,., a. 101975 BkCh Bak East 1 - REVISIONS re 3M'"Fire Barrier Duct Wrap 615+ 3M"Fire Barrier Duct Wrap 615+ 3M'"Fire Barrier Duct Wrap 615+ BY Hanging Support Details for Fire-Rated Ductwork(FigsrefU) F�ww and Bandiag InstaDat (Figure 15) _-.__._Cut Typical Through Penetration Firestop System(F%nre 19) Elbow Pattern Installation( -----Fold Hour Through Penetration Fin-Rated Wood/Gypsnm floor/C g Assembly Note:To facilitate the application of 3M Fire Barrier Duct Wrap 6I5+ Y Suggested Installs n A) -� _ _ _Overlap 1- Systems eilin Assem 9. Ventilation Air Duct Installation Techniques �that�rods& �°g`rs are°"�i�`�`"'�e1Ve'°�'`� '.Perimeter , following dimensions are recommended: 1.Floor/ceiling assembly *x �STAk0AR0 2.3"(76.2mm)min.overlap I 3M'"Fire Barrier Duct Wrap 615+should be installed per the application design listing in accordance with the following basic installation instructions. 1 laver laver x , 2.Duct 3.Hole cut(off-center) j�-' �. • 1-Layer Ventilation Duct Note:This general instruction for applying 3M-Fire Barrier Duct Wrap 615+details a one wrap installation of 1.Rod-to4we dud clearance(Y) 4"(102mm) 6"(152mm) 3.One or two layers 3M'"Fire Barrier Duct Wrap 615+ Method([SO b944) 3M"'Fire Barrier Duct Wrap 615+blanket applied directly to a ventilation duct.To minimize waste,the 3M'"Fire 2"(51 ruin 4"(102mm Note:Place overlap on opposite side of horizontal pattern. I ! Barrier Duct Wrap 615+material should be rolled out tautly before measuring.The single layer of 3M-Fire Barrier 2.Added rod length(X) ) ) "'` - 4.Banding or pinning I Duct Wrap 615+blanket is wrapped around the perimeter of the duct and is cut to a length to overlap itself not less � Suggested Banding Pattern Installation(B) i j VerticaUHorizontal Elbow Pattern ( 5.3M"Fire Barrier Packing Material PM 4,4 pcf mineral wool,or scrap duct wrap I than 3"(76.2mm),this is known as the"circumferential"or"lateral"joint.The interface between adjacent blankets ` l � �� l.Grease of ventilation duct i ,�' (min.33%compressed) forms the"longitudinal"joint.The minimum overlap requited at the longitudinal joints is a minimum 3"(76.2mm) Q foil or FSK is used to seal all cut edges of the blanket and any tears in the foil scrim. Nam:System integrity is limited by quality of installation.Consult current ST"/tNWD 2. 1 or 2 layers of 3M"'Fire Barrier Duct Wrap 615+ _ 6.Sealant Fire Barrier Water Tight Sealant Silicone NS,Sealant Fine Barrier Water Tight overlap.Aluminum lace using filament .The 3M'"Fine Battier independent testing laboratories(e.g.Intertek UL)for Design or System Details. j -za- Sealant t 003 SL,or 3M" Fire Barrier Silicone Sealant 2000+ As an installation aide,the blanket may be temporarily held m p g (application dependent) r4 Duct Wrap 615+requires permanent fastening with stainless(or carbon)steel banding,or with rows of weld,pins 3.Steel or stainless steel banding 1/2"(12.7mm)wide min typical I Note:Sealant to be applied at a minimum 5l8"(15.9mm)depth. (impaling or cup head style). for permanent fastening with max.10-112"(26.7cm)spacing - -t, Second Piece i f 3M'Fire Barrier Duct Wrap 615+ 4.3"(76.2mm)overlay(typical throughout application) Three approved ventilation duct installation techniques: Hanger Penetrations of Wrap Envelope for 5.Min.3"(76.2mm)perimeter overlap(not shown) r Grease or Ventilation Duct Systems(Figure 11) Note:System integrity is limited by quality of installation.Consult current 31r1 "' Fire Barrier Duct Wrap 615+ Note:1-layer application depicted.When 2-layer application First Piece- imdeperulent testing laboratories(e.g. lnlertek. (Ill for Design or System Details. 1.Min.1/2"(12.7mm)crown of 3M"'Fire Barrier Sealant CP 25WB+or 3000WT is required,replicate these steps with outer joints staggered 2.Tape seams-min.3"(76.2mm)wide aluminum tape, a min.3"(76.2mm)from inner joints.Banding is required 7A.Telescoping 3"(76.2mm)Overlap Wrap Rgm 7A Tabscoping 3M"'FSK Facing Tape 3320(or equivalent) on outermost layer only. 615+ With the Telescoping Overlap Wrap method,each blanket overlaps ( J 3.1 or 2 layers of 3M-Fire Battier Duct wrap 615+(application dependent) Typi Fire Barrier Duct Wrapcal Through Penetration Flresrestop System(Figure 20) fi one adjacent blanket.Each blanket has one edge initially exposed Typical 4.All Threaded Rod Note:System integrity is limited by quality of installation_Consult current 1-or 2-Hour Through Penetration Systems-Gypsum Wan or Gypsum Sha1t<wall which is then covered by the edge of the next blanket as shown in independent testing laboratories(e.g.Intertek: UL)for Design or System Details. Figure 2A. 3"(76.2 min) ~` 5.C-channel or angle iron trapeze support 1 a.Gypsum wall assembly -- - r --� -=- l. Single layer of 3M'"Fin Barrier Duct Wrap 615+ 1-1/2"(38.t min) = � 6.Seismic bracing Wire i ib.Gypsum shaftwall assembly - 2. Steel banding 1/2"(12.7mm)wide min.typical diminish the T Rating f the a uto f the Note:The inclusion of metallic items penetrating out of the 2 Duct ��envelope may _ 0 3M'Fire Barrier Duct Wrap 615+ 3. 3"(76.2mm)min.longitudinal overlap _'I \ -- ,'� ;--- ', - 21•(53.3 cm) - 0 Suggested Installation for 90°Turn(Figure 16) 3.One or two layers 3M'"Fire Barrier Duct Wrap 615+ - �' A-F(representative field-cot duct wrap sections) A (layering dependant on application) O , _ 24•(61 cm) -- B C ' D E 4.Banding or pinning Note:System integrity is limited by quality of installation. 1.Duet Consult current independent testing laboratories 2. 1 or 2 layers of 3M-Fire Barrier Duct Wrap 615+ 5.wool Fire Barrier Packing Material PM 4,4 sse mineral (e.g. Intertek, UL)for Design or System Details. (application dependent) � wool,or scrap duct wrap(min.33%compressed) "(76.2mm)Overlap Wrap -- -�- -- -Checkerboard 3 76 ) P 6.3M"'Fire Battier Sealant 1000NS or 2000+applied - 7B.Checke ( Figure 78 Cihedcerboard Overlap - u With the 3"(76.2mm)Checkerboard Overlap Wrap method (pniss Section 3.Sc otch�Filament Tape 898(�equivalent) SteD 1 _5 2 p 3 C at a min.5'8"(15.ymm)depthft blankets with both edges exposed alternate with blankets with A r--- blan g 3M'"Fire Barrier Duct Wrap 615+ Pine or.Conduit Parallel to lluct 4.Steel banding 1/2"(12.7mm)wide thin.typical Note:The assembly can be either a symmetrical covered edges,as shown in Figure 2B. Conduit Penetrations Of Wrap Envelope for for permanent fastening � � gypsum wan or an asymmetrical gypsum shafMaB. t w 615+ 3"ps.2 min) - 12 I. Single layer of 3M'"Fire Barrier Due rap � Grease or Ventilation Duct Systems(Figure ) 5.Min_3"(76.2mm)perimeter overlap i B --j r--I 2. Steel banding 1/2"(12.7mm)wide min.typical 1-t/2•(38.1 min) / 1.Duct --`-_ 6.Min_3"(76.2mm)longitudinal overlap 3. 3"(76.2mm)min.longitudinal overlap ,%,' '! ' - 2.1 or 2 layers of 3M'"Fire Barrier Duct Wrap 615+(application dependent) Note:2-layer application depicted.When 1-layer �----18•(45.7 cm)----� i application is used,install banding(item 4)as a 2 LM j 3.Min.ItT'(12.7mm)crown of 3M-Fire Barrier Sealant CP 25WB+ permanent hold. , 1- -- 24"(61 an) or 3000WT StSteu 4 _ NOW. items The inclusion of metdk is penetrating out of the _ Steo 5 I Stet _ wrap envelope may diminish the T Rating of the enclosure = _ _ Penetrants within the wrap envelope are not protected from the p Note:System fisting ty is limited be quality of installation.Consult current Details- effects of a grease$n. � t 1 ►t r I t it independent testing laboratories(e.�g Intertek UL)for Design or System Details. 7C.Butt Joint with Collar Figure 7C Butt Joint with Collar With the Butt Joint and Collar method,adjacent blankets are butted (Cross Seetlon Ytett9 E _ _-_.__.-__r__-- _ tightly together and 6"(152.4mm)wide collar of duct wrap is _-_ _ 3M'Fire Duct Wrap 615+Typical Through Penetration Firestop System(Figure 21) centered over the joint,overlapping each blanket by 3"(76.2mm) 6"(152.4 min) - minimum as shown in Figure 2C. 3•p6.2 mm) i- --r- 3"p6.2 mm) 1-or 2-Hour Through Penetration Systems 1. Single layer of 3M-Fire Barrier Duct Wrap 615+ 1-1/2"(38.1 min) -a Note:System integrity is limited by quality of installation. �t F STpR$ _ 4-1/2"(11.4em)Concrete Floor or Wail I`i �- 2. Stec}banding I/2"(12.7mm)wide min.typical Consult current independent testing laboratories Pine or Conduit Perocrndicular to Duct 1.Floor/ceiling or wall assembly I , S (e.g.Intertek, UL)for Design or System Details. 2 Note:System integrity is limited by quality 3. 6" 152.4tnm}min.wide 3M" Fire Barrier Duct !l _1 of installation.Consul!current independent t t Duct ( f testing laboratories(e.g.Intertek UL)for 3.One or two layers 3M'"Fire Barrier Duct Wrap 615+(application dependent) 1 Wrap 615+Collar I--12•(304.8 min) - _ - `� Design or System Details. �_ _ _-_ 2a' (lit col _ 4.Banding or pinning I � � "2 4. Tightly butted �_ ._ ___ _ >� Y 1 3M'"Fire Barrier Dud Wrap 615+ 13 W 15+ 5.3M"Fine Barrier Packing Material PM 4,4 pcf milieus! \ mtiaattter Suggested Two-Sided Wrap Iestallstlon(Figure ) 3M'"Fire Barrier Duct rap 6 wool or scrap duct wrap(min.33%compressed) - 1.Concrete slab s. Suggested Branching Duct Details(Figure 17) 6.3M'"Fire Barrier Water Tight Sealant 1000 NS,3M'"Fire Barrier Water - �-- -- 2. 1 or 2 layers of 3M'"Fire Battier Duct Wrap 615+ 1.Duct Tight Sealant 1003 SL,or 3M'"Fire Barrier Silicone Sealant 2000+ 1 � �iin AT-Fire Barrier Duct Wrap 615+Ventilation Duct Systems(FhgHre 8) (application dependent) Note:Sealant be applied at a minimum 5B"(15.4mm)depth. 2.Full width pieces of 1 or 2 layers of 3M'"Fire Barrier Duct 1.3M-Fire Barrier Dud Wrap 615+,1-layer Wrap 615+(application dependent) ////// For wall assembly apply sealant to both sides of wall To 3.Concrete fasteners-min. 1/4"(6.35mm}ilia.steel (3M'"Fire Barrier Water Tight Sealant 1003 SL riot suited for wall applications.) i ( � perimeter concrete anchors 3.Steel banding 1/2"(12.7mm)wide min.typical for permanent fastening 2.permeter(lateral)joint min 3"(76.2mm)overlap I I 3. i(19mm)wide filament tape 4. M"'1/8"(3.18mm)thick x 2"to 3"(50.8mm to 76.2mm) 4.3 Fire Barrier Duct Wrap 615+(field cut) wide bar stock perforated 12"(30.5cm)O.C. Note:System integrity is limited by qua/hy of installation.Consult current 4.Steel banding I/2 (12.7mm)wide min.typical for permanent fastening Note:Install first piece onto the inside of the inner duct area independent testing laboratories(e.g.Intertek UL)for Design or System Details. 5.Longitudinal joint min.3"(76.2mm)overlap 5.Duct and then install the adjacent pieces so they overlap at the edges n 6.Steel banding IR"(12.7mm)wide min.typical a minimum of 3"(76.2mm).When an application requires a 6.Metallic ventilation duct for permanent fastening second layer of duct wrap,install the second piece over the Note:System integrity is limited by quality of installation. 7 Banding clips / first piece and overlap at the edges a minimum of 3"(76.2mm). Duds>24"(60.9cm)wide require Pinning on the bottom side of horizontal ducts and on a minimum of one of the wider sides of a vertical duct.Vertical ducts require pinning on all sides>48"(121.8cm). ( 3 Note:System integrity is limited by quality // // 0 of installation.Consull current independent �`:t� �,•� testing laboratories(e.g.Intertek, UL)for / Second Piece Note: rem integrity is limited by quality `t` �'°� Design or System Details. No Sys gr r s� o installation.Consult current independent testing laboratories(e.g.Intertek, (IL)for Design or System Details. Ar Fire Barrier Duct Wrap 615+ >_a•psz...► Note:System integrity is limited by quality Suggested Thrft Sided Wrap Installation(Figure 14) _. �-Q - of installation.Consult current independent .Concrete slab assembly testing laboratories(e.g.Intertek, UL)for 10. Grease Duct&Ventilation Air Duct Installation Techniques Design rn System fktails. First Piece 2.l 0 2 layers of 3M'"Fire Barrier Duct Wrap 615+ blies with maximum cross sectional areas of 24"x 24"(610mm x 610mm)must be supported (application dependent) Duct Support Horizontal dud assem 3M'"Fire Barrier Duct Wrap 615+ (Grease&Ventilation) with min.3/8"diameter(9.Smm),all-thread steel rod and 2"x 2"x 1/8"(51nun x 51 nun x 3.2mm)steel angle, 3.Concrete fasteners-min.1/4"(6.35mm)dia.steel concrete anchors spaced a maximum of 60 (1524mm)on center.A min.clearance of 0"(Omm)and a max.clearance of 6"(152trun) 4 1/8„(3 18mm)thick x 2"to 3"(50.8mm to 76.2mm)wide bar stock Suggested Duct Wrap/Shaft Transition Installations(Figure l S) is required between the vertical edge of the blanket material surrounding the duct and the steel rod.Horizontal duct perforated 12"(30.Scm)O.C. c� asses blies with max.dimensions of 24"x 48"(610mm x 1219timt)must be supported with min. 1/2"diameter 1.Fire barrier gypsum shaft assembly dam' (12.7mm),all-thread steel rod and 2"x 2"x 1/4"(51 min x 5ltnm x 6.4mm)steel angle spaced a max.of 60" 5.Duct 2.5/8"(15.88mm)depth of 3M'"Fire Barrier Sealant T V LO (I124mm)on center.A min.clearance of 0"(omm)and a max.clearance of 6"(152mm)is required between the 6.Steel banding I Ir(I2.7mm)wide»tin.typical fo pemiancnt fastening j 1000NS, 1003SL or 2000+ vertical edge of the blanket material strrroitttding the duet and the steel rod.Vertical ducts mast be supported at every 3. 1 or 2 layers of 3M'"Fire Barrier Duct Wrap615+ M cq E floor line on the top of the slab. 7.Banding clips (application dependent) N � � � rn Pinning&Banding 3 iY"' 4.3M"'Fire Barrier Duct Wrap 615+(use small scrap piece) Requirements ax ,, t„s. : ..; 5.Fire barrier concrete floor assembly UK Note:System integrity is limited by quality of installation. p � c wkkh 5 24" Consult cwmnt independent testing laboratories 6_Air gap as requited by local mechanical code(grease ducts) ( I I �= " r (e.g.Inter&*UL)for Design or System Details. L 2V'<width s 48 7.Extend duct wrap into shalt a min.distance that meets local � 1 i I I r -0 tC) width>48„ r code requirements for clearance to combustibles I I I I I II I Ii 3M-Fire Barrier Duct Wrap 615+ Pinning guide(Figure 9) Note:System integrity is limited by quality Additional pinning to prevent sagging of the dud wrap.For all ducts greater than of installation.Consult current independent 241, 60cm in width,pinning is required to support the blanket on the bottom testing laboratories(e.g. Intertek, lit.)for horizontal surface and on the outside face of a vertical duct run.Space pins a Design or System Details max.of 10-1/2"(26.7cm)apart in the direction of the blanket width,and a max. 12"(30cm)apart in the direction of the blanket length. C Materials and i ment _.. •Minimum 12 gauge copper-coated steel insulation pins used with minimum 2-I/2"(63.5mm)square galvanized steel or stainless speed clips or 1-112"(38.1 rum)dia.round or equivalent . . . . . sized insulated cup-head pins t t •Capacitor discharge stud gun Note:Either apply min.12 gauge copper-coated impaling pins to the bare duct using a capacitor Note:System integrity is limited by quality of installation.Consult cwmnt discharge gun or apply min.12 gauge cap-head independent testing laboratories(e.g. Intertek UL)for Design or System Detadr. s after the duct wrap is installed. pin a a� o 0 �a oub ll Ile- !+ , J06617 H�i ,f Sttttat 14- Of 8111011% atilttM awrrhtrwu GRE15tiE✓SFOhIE �. `{~\8 ,` ``\, - 09 `.- ?n.�j� 4_ 1 ' HOOD SCHEDULE RFhGE ?0 REA4tNM i t Lrropr SUPPLY CONNECTION EXHAUST CONNECTION FILTERS LICsHT L 2y L_p ,� `,� �\.`. �% � %'�9�r K4�ADOT I,�Gsp ti 15'+ � C3G� NO. LENGT+a X. WIDTH CAOOKINd TOTAL TOTAL QTY. WEIGHT LENGTH HOOD CONSTRUCTION WOOD EXTENSIONS I ,fl�� � � i }2 �, �� � i ! r� TEMP. CFM SIZE CFT't SIZE TYPE TYPE i - ,o ;1 P ;, 9 ,� C De ! � I f 430 STAINLESS STEEL - 20 430 STAINLESS STEEL - 20 __'�C, \��, iti_. b 4 ULTIMATEAIREy v 2U $CREW-IN COMPACT FLUOR ---- " GAUGE W/ALL WELDED JOINTS GAUGE UV ALL WELDEC JOINTS / ,w �. aow of;iwS�s>'�''� �" �i� • �" i.65 r = W i . ................ ,.............. 1 i i� 4�5 ' Q) z r �. — EXHAUST FAN SCHEDULESU 'LY FAN SC1-=[)ULE _ . w - ,ICE N ' .._.. . % .....• * �. _•.�.: "-_ ._,. Stow_ —— — -- w ' CAN NO, MANUFACTURER MODEL NO. CFM RPM HP pHA$E VOLTAGE REMARKS FAN NO. MANUFACTURER MODEL NO. GFM HP PHASE VOLTAGE RE1�tAFcKS ' ` lY -" Y BUILDING 1 rs r _ 2_STOR U1dBU5 !� :._ tKN31 SF � t5T-ILOOF 0 z ,1 R1N �t I_ _ MM ^ 4- Lt I 0�' T f ► 1 W >20r C�-I�.v 16sv r �Z �. I v c��- Pie c��- Z� bs z � � tRnPOSEo RETAi I t , ;HpwRC)OM 2N� F odR A550GATE0 SF R001� 25 C S?ORY BUILO{NG I RETAI `' 055 LEA fA�t10E 1pRiN? 5 i t5620 Sf FOO GROSS 1 TOTAL 1250 p100 Sf TOTALI a , fLOOR 1320Asf STORAGE p sE6'" �EASABLE L-2 1 ^ { L- rRst Fl ook ,sot ONL _� I I :E}. O }� ram• , F-; _ - j Mh ElfI ,nre:,r,c o s L 6>v!s; f NMI 47,.�6 3 si0i�.,�£'.#—E(A{POc>F� -- - l�{"/l6ll!/!� ' ': �wV M 7A3,i6 „•.a S (N!'y;lsyf MIV OUT 46_ ,, ASH1 3 66 KCPW _ —!S �- -1 4" - a- 9>6 _ Th � 1 * CL r - wop 100W VAPORPROOF , �P�. j � - LNCANDESCENT LIGHT i ? P . ' 3" STANDOFF ~ THE HOOD CLEARANCE FROM Q LliYll A FD-COMD US HOLE AND CONIBUSIIBIE MATERIALS 20"U.I..CLASSIFIED LS LN COMPLIANCE WITH LOCAL BAFFLE-TYPES p`` LtIKE&tElyTS RMFORAT®PANEL CODE REQ �-, GREASE FILTERS ` GREASE DRAIN WITH REMOVABLE CUP - t a Xr MIN 1 41r MAX It co > to In c�v a E Irl CD 78' TYP. y 1 - i It 4 � Q 6 o E co EQUIPMENT I _ l I k 0 03 0 HOOD ELEVATION - DETAIL SCALE: NT5 GENERAL NOTES: r:» 0 L I. O ALL ELECTRICAL 'FIELD' CONNECTIONS ANDRELATED INTERCONNECTIONS .0 ARE BY THE ELECTRICAL CONTRACTOR. 2. - ALL C.00KINCs EQUIPMENT TO SHUT OFF IN THE EVENT OF FIRE. 3, - EXHAUST FANS TO TURN ON IN T14E EVENT OF FIRE. ` ULTIMATE AIRE HOODS ARE BU T IN 4_ - AIR BALANCE FOR SUPPLY AND EXHAUST FANS SHALL BE BALANCEDTO PROVIDE A NEGATIVE PRE-*ftRE AT THE HOOD- � ' t � SCALE ` COMPLIANCE WITH NFPA 19b jjj 5. - INSTALLATION TO BE IN FULL COMPLIANCE WITH Nri=PA 96 AND THE FFIA� NEW YORK STATE BUILDING1 CODES. -- T OO L I]