SEP-0298-2018 ft° TOWN OF QUEENSBURY
2 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development- Building& Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: SEP-0298-2018 Date Issued: Monday, October 22, 2018
This is to certify that work requested to be done as shown by Permit Number SEP-0298-2018
has been completed.
Tax Map Number: 297.13-1-38
Location: 3 BEACON HOLLOW WAY
Owner: Susan Sweet
Applicant: Susan Sweet
This structure may be occupied as a: Residential Septic Alteration
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the (I4440 4
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
04116k TOWN OF QUEENSBURY
r
'� 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
0 Community Development- Building & Codes (518) 761-8256
BUILDING PERMIT
Permit Number: SEP-0298-2018
Tax Map No: 297.13-1-38
Permission is hereby granted to: Peter Durrin
For property located at: 3 BEACON HOLLOW WAY
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: Susan Sweet Septic Disposal-Residential $0.00
Owner Address: 3 Beacon Hollow Way Total Value $0.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Peter Durrin
Plans&Specifications
Residential Septic Alteration
$ 75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,May 29, 2019
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of een ry; es. , /y 29 2018
41
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only
—_ 742 Bay Road,Queensbury,NY 12804 �- -- �---.—_.._
town of Qticen.o i .- Permit#: U Z� Ss _�1
P:518-761-8256 www.queensbury.ne
Tax Map ID#: -? �tr' /2 ( � — Permit Fee $ 7 S �; Invoice#: t` L`�
H MAY 2 'flsQ '; :
Project Location: �` c 1�1 ( I
U L L '' Septic Variance? Yes No
Primary Owner(s) ,3 04) T 3t1 �� '.
Mailing Address t E-'t�-►Ci-)ti-1 A.Cit i 0 :\ P`
Phone & Email (c ,.q: 7_0 a_T--;LA_
Installer/Builder c)E VON2\kt•
Mailing Address EAA 0 IAOLLc k`
Phone & Email ,r.�1?; 2— t Le(07)
Engineer N
Mailing Address
Phone & Email
Contact Person for Building &Code Compliance: cVl9\ i i Lit Phone: , *I$ 2.3Z. I(0(3
RESIDENCE INFORMATION:
Year Built Gallons #of bedrooms X gallons per =total daily flow
per day bedroom Garbage Grinder Yes No
1980 or older 150 9 Installed? (circle one)
1981-1991 130 Spa or Hot Tub Yes No
Installed? (circle one) ,
1992-Present 110
PARCEL INFORMATION:
Topography j, lat Rolling Steep Slope %Slope
Soil Nature V Sand Loam Clay Other
Groundwater At what depth?
Bedrock/Impervious material At hat depth?
Domestic Water Supply VMunicipal _Well (if well, water supply from any septic system absorption is ft.)
Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect)
PROPOSED SYSTEM FOR NEW CONSTRUCTION:
Tank size 13 L gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub
System Absorption field with#2 stone Total length ibiD ft.; Each Trench ft. t=iVf V
Y p
Seepage Pit with#3 stone How many: ; Size:
Alternative System Bed or other type:
Holding Tank System Total required capacity? ;tank size ', ;#of tanks
NOTES: 1. Alarm system &associated electrical work must be inspected by a Town approved electrical inspection
agency; 2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved.
The installed system must match the septic layout on file—no exceptions.
Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material
representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I
have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage
Disposal Ordinance.
PRINT NAME: AWL'MJ DATE: li‘1.fk
SIGNATURE: - DATE: ci,th,iii
Town of Queensbury Building&Code Enforcement Revised March 2018
INSPECTION WORKSHEET (SEP-007503-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:SEP-0298-2018Case Module:Permit
Inspection Date:10/22/2018Inspection Status:Passed
Inspector:John O'BrienInspection Type:Septic
Job Address:3 BEACON HOLLOW WAYParcel Number:297.13-1-38
Queensbury, NY 12804
Contact TypeCompany NameName
Primary OwnerSweet, Susan
ContractorDurrin, Peter
Granted PermissionDurrin, Peter
ApplicantSweet, Susan
Checklist ItemPassedComments
Building Inspector NotesYES5/29/18 Septic System Partial Approval
-Correct distribution box and install speed levelers.
Call for reinspection!
7/11/18 Septic System Not Approved
-The 2 Side Leach Lines are draining equally after I
adjusted the levelers. The center one is to high The and
the outside lines are doing all the work. All 3 Lines need
to leach equally for the system to function correctly.
Please correct the d-box and call for a recheck.
10/22/18 Septic System Approved-Distribution Box
corrected.
Soil Type: SandYES
Soil Type: LoamYES
Type of Water: Municipal / Well WaterYES
Waterline separation distanceYES
Absorbtion Fields: Total LengthYES160’
Length of Each TrenchYES3@50’ End looped.
Depth of TrenchesYES18―-24―
Size of StoneYES#2
Building to TankYES4― sch40
Tank to Distribution BoxYES4― sch40
Distribution box to Field / PitYES4― pvc to 4― pvc perforated end looped
Oct 22, 2018Page (2)
INSPECTION WORKSHEET (SEP-007503-2018)
Checklist ItemPassedComments
Opening Sealed:YES5/29/18 Septic System Partial Approval
-Correct distribution box and install speed levelers.
Call for reinspection!
7/11/18 Septic System Not Approved
-The 2 Side Leach Lines are draining equally after I
adjusted the levelers. The center one is to high The
outside lines are doing all the work. All 3 Lines need to
leach equally for the system to function correctly. Please
correct the d-box and call for a recheck.
End CapYESEnd Looped
InletOutlet Pipes & BafflesYES
Manholes 12 or less below gradeYES
Locations / SeparationsYES
Foundation to TankYES10’
Foundation to AbsorptionYES17’ below basement slab
Conforms as per Plot PlanYES
Location of system on propertyYESMiddle Rear
System Use StatusYES5/29/18 Septic System Partial Approval
-Correct distribution box and install speed levelers.
Call for reinspection!
7/11/18 Septic System Not Approved
-The 2 Side Leach Lines are draining equally after I
adjusted the levelers. The center one is to high The
outside lines are doing all the work. All 3 Lines need to
leach equally for the system to function correctly. Please
correct the d-box and call for a recheck.
10/22/18 Septic System Approved-Distribution Box
corrected.
O'Brien, John (Inspector)
Oct 22, 2018Page (3)
.1")
3-5/2-can \Ao\10
r c- � .._ , Co
! c,..> a" 7-`-.0 ol-E. co c
! cNt ,LU
:01 L1'. 6 Lu_ 0 0
'^,± 3
U
0
C.---' 0
Col O w
,...._______„_. - • q- 0 g 4E'
iiA 6 ' ' A , o a)
' d a)(13 Fn-
.
1.1) C � ma,
126
5-0I.(53
N 0 co
5 f i
i ‘
J <r:~TIC Pl,QT PLAN
-SO i I HAVE SEEN OR OBSERVED ALL OBJECTS
SUCH AS HOUSES, WELLS, TREES, FENCES, ETC
SHOWN ON THIS DOCUMENT.I HAVE PERSONALLY
MEASURED THE DISTANCE SET FORTH ON THIS DIAGRAM.
(i--.4 ------C-c,-A-vJ--- .5=es---/e
A. (61 ao piPe. a SIGNA 1 URE DATE
RSA) PAh/
i
lb d_h___;,,,,.„._L_L -__L-, ,,oe.,... r..._j_la, I'7 441°'" E C om. T C. a CL-- C',E ,N
C '-, S-C-_, •A_____L__5 i M
4 &Pit As acc " 0,,,,, -6—tAcZ Ace../,) e
b /-70 zei.t. ). 1--/e/c/ WN OF QU N •
BUILDING & ' O B .: rpri.:
Reviewed B • 4 4. /
.2 loge_
Date: laffir::. *