Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-0710-2018
TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0710-2018 Date Issued: Monday, April 22, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-0710-2018 Tax Map Number: Location: Owner: 308.12-1-39 127 BURNT HILLS DR Michaels Group Homes, LLC Michaels Group Homes, LLCApplicant: This structure may be occupied as a: Single Family Dwelling w/gas FP 1681 s.f. Garage 466 s.f.By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement { TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 a Community Development - Building& Codes (518) 761-8256 ___gin BUILDING PERMIT Permit Number: RC-0710-2018 Tax Map No: 308.12-1-39 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 127 BURNT HILLS DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $250,000.00 Owner Address: 1 Marions Way Total Value $250,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marions Way Mechanicville,NY 12118 Plans&Specifications Single Family Dwelling w/gas FP 1681 s.f. Garage 466 s.f. $ 1,654.30 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,November 20, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of ury; J�ues .,, '- •er 20, 2018 SIGNED BY: ' " for the Town of Queensbury. Director of Building&Code Enforcement Email: i Lo CP LI- e. e�iv-v 5_,,�,...�--. L,L -% Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 • Town of Queensbury Thames R. Van Ness Highway Superintendent Highway Home (518) 745-0929 Department 742 Bay Road —Queensbury, NY 12801 David Duell Phone: (518) 761-8211 Deputy Highway Superintendent Fax: (518) 745-4466 Home (518) 743-0938 DRIVEWAY PERMIT DATE: 11 1 111'a APPLICANT NAME: N11C.-1-115 5 CoZQ.?' kcii , TELEPHONE NO.: 512) .eA .bat t ADDRESS TO BE INSPECTED: l2-7t RETURN ADDRESS: 1 N1NiekoraS L(iA9--r IHW—k-1ANlG�It NY Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt: (or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent FUEL BURNING APPLIANCE & Office Use Only CHIMNEY APPLICATION Permit#: OC-014 2 Permit Fee:$ limn of(Zrcerrshurr 742 Bay Road, Queensbury, NY 12804 Invoice:#: P: 518-761-8256 www.queensbury.net Project Location: 121 t -LV S Z sJ . Tax Map ID #: Room of Install: L-1NL Planned Install Date: 11 D **ONE APPLICATION PER APPLIANCE** CONTACT INFORMATION: • Applicant: Name(s): , ►LC... Mailing Address, C/S/Z: 1 m is k W,a.Y, Ml3k-1A4•XICuiu_e Ni'` 1ZL' Cell Phone: ( ) er ct 30'4.►► Land Line: ( ) Email: J 42s1 .1i. 2 tdoo-i.beatS q rax_p•cot.% • Primary Owner(s): Name(s): 1 = Mailing Address, C/S/Z: Cell Phone: _( ) Land Line: _( ) Email: • Installer/Builder: Business Name: -1' i-t %c * Pit-IA 0 LI UR-- Contact Name(s): C-tre-erA 1-{P.V4g)Iz=NIA Mailing Address, C/S/Z: 17bco 11.7...opS Cell Phone:_( 5tsb ) Sie t.`i Land Line: _( ) Email: Contact Person for Building & Code Compliance: To4 e wct sc-4o Cell Phone: ( S►(;6 ) Land Line: ( Email: IJAt-1-t -Lsc, cC Fuel Burning Appliance &Chimney Application Revised March 2017 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove Fireplace Insert Fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) X Fireplace, factory built** **Manufacturer's name: Model it 50 C0-30"[Qt> SOURCE OF HEAT: Wood Coal Pellet )4 Gas CHIMNEY INFORMATION: Masonry: block brick stone Flue: tie steel size, in inches Material*: double-wall triple-wall insulated (*Manufacturer's name: Model #: ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces & chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: iL1 - b (456jri SIGNATURE: ,/ �(�, DATE: ) l y i' Fuel Burning Appliance &Chimney Application Revised March 2017 • SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury,NY 12804 (own of(Lccn,hurt P:518-761-8256 Permit#: ��'�' � - sue(► www.queensbury.net Tax Map ID#: Permit Fee:$ ; Invoice#: Project Location: t Z-1 G Septic Variance? Yes No Primary Owner(s) MNG+0.eCE3..G. cc x- ' 4 ,Ltd Mailing Address 1 IAp c› .S �� �✓iS.tkb•dJl(_\1►1.is3", t -i 12-11O Phone & Email 5,'2) • cork j e i c-Nt_Sc� ,�. crfl Installer/Builder ••iccA\t N,ct Mailing Address RC5c=5; + 4.1 N.Y Ze9 Phone & Email .74"7,�131 i Engineer tf1,c� �1yC,�1 �s pc. Mailing Address Icy 1z> ctv2,,p, IaY 12-t, 04 Phone & Email .7 4,5 Contact Person for Building&Code Compliance: `'r Phone: 51€5 •a""3-1 •%�44 RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes lo'� 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes Installed? (circle one) 1992-Present 110 3 3 6 PARCEL INFORMATION: Topography }C Flat Rolling Steep Slope %Slope Soil Nature V Sand Loam Clay Other Groundwater At what depth? Bedrock/Impervious material At what depth? i(Ofi,/- Domestic Water Supply �cMunicipal _Well (if well, water supply from any septic system absorption is ft.) Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size 1 °AL..' gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length l 5—D ft.; Each Trench 5-6 ft. Seepage Pit with#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size ;#of tanks NOTES: 1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency; 2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. L( ZC PRINT NAME: `ti ( '� (i' - 5605 DATE:- I l SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Revised February 2017 RElrt/Rate - Residential Energy Analysis and Rating Software vI5.7.3 Gross Area or Perimeter 169 231 21 19 1328 208 24 Cavity Cont. R-Value R-Value 21.0 0.0 Glazing or Door U-Factor 0.300 0.310 0.143 0.300 0.0 0.0 19.0 19.0 UA 0 69 -0 0 53 I 7 New York Compliance Certificate Assembly Joist 2: Cond -> ambient \{indow 1: U=0.30, 5=0.27 Door 1 : Front'Custom-R-3.23 Door 2: R7 steet insu[ Basement Walts Walt 1: R-19 Draped, Futl Wat[ 2: R-19 Draped, Futt Window 2: U=.0.30, 5-0.27 lnfiltration Htg:2.67 Ctg: 2.67 ACH50 }techanical Equipment Heating: Fuet-fired air distrihrtion, 64-0 l6tuh, 95.0 AFUE. Water fleating: Csrventional, Gas, 0.65 EF. Cooting: Air conditioner, 28.0 kBtuh, 13.0 sEER. Required signatures vary depending upon rtate and or tocal codes, requirements and regulations. Check with pur tocat buitding department to determine which signatures are required for your application. Builder or Authorized Employee I certify that the home tisted above shatt be buitt to meet or exceed atl requirernents of the 2015 IECC as arnended by the 2016 New York State EnerEy Conservation Construction Code and att current energy codes specific to the tocat jurisdiction in which the home is buitt. 5ignature Date l, Stan Grajny, PE of GRAINY Consutting, LLC, certify that the horne listed above, as modeled meets or exceeds att requirernents of the 2015 IECC as amended by the 2016 New Yodt State Energy Conservation Construction Code and atl current energy codes specific to the [oca[ jurisdiction in which the lurne is buitt- Name - Title Rater SMN GBTTT\JY Narne - Title REtrt/Rate - Residential Energry Analysis and Rating Software v't 5.7.3 This information does not constitute any warranty of energy costs or savings. CI 1985-2018 NORESCO, Boutder, Colorado. '\rn I further attest that I am a certified Home Energy Rater and affitiated *itfl $E F- a HERS Proyider accredited by RESNET and adhering to the requirements of the Residentiat Energy Services Network RESNET Standards. cq/trlzot{Dad-1- New York Compliance Certificate REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 ____________________ Permit # ____________________ Permit Date Confirmed: - No Registry ID Project Title: 127_BurntHills Report Date 2019-04-18 Data Filename MichaelsGroup_127BurntHillsQueensbury_041819_V.15.7.3.blg Energy Code 2015 IECC as amended by the 2016 Supplement to the New York State Energy Conservation Construction Code Location Watertown, NY Construction Type Single-family detached Heating Type Natural Gas Glazing Area Percentage 15% Heating Degree Days 7491 HERS Index 53 Construction Site Owner/Agent Designer/Contractor HERS Rater 127 Burnt Hills Drive Unknown Michaels Group Homes GRAJNY Consulting, LLC Queensbury, NY 12804 127 Burnt Hills Drive 1 Marions Way Stan Grajny, PE Queensbury, NY 12804 Mechanicville, NY 12118 Certification# 5609922 N/N 518-899-6311 518-221-3240 Building Information Conditioned Area (sq ft) 3362 Conditioned Volume (cubic ft) 28577 Insulated Shell Area (sq ft) 6872 The items below will be inspected for energy code certification. Any deviation from these specifications should be brought to the attention of the HERS Rater, as soon as possible to assure that the project will still comply with energy code requirements. Compliance (must pass either UA or Performance Path) Code Compliance Pass UA Path Fail Performance Path Pass Duct R-Value Pass Maximum Energy Cost($/yr)2023 Maximum UA 290 Your Home Energy Cost($/yr)1886 Your Home UA 305 Better Than Code (Perf)6.0% Worse Than Code (UA)4.9% Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Glazing or Door U-Factor UA Ceilings Roof 1: R38,FG1,X-24 1681 38.0 0.0 68 Above-Grade Walls AG Wall 1: R21,FG1,6-24_A 1521 21.0 0.0 84 AG Wall 2: R21,FG1,6-24_A 234 21.0 0.0 13 Joist 1: Cond -> garage 26 21.0 0.0 0 New York Compliance Certificate REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado.Page 2 of 2 REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Glazing or Door U-Factor UA Joist 2: Cond -> ambient 169 21.0 0.0 0 Window 1: U=0.30, S=0.27 231 0.300 69 Door 1: Front-Custom-R-3.23 21 0.310 0 Door 2: R7 steel insul 19 0.143 0 Basement Walls Wall 1: R-19 Draped, Full 1328 0.0 19.0 53 Wall 2: R-19 Draped, Full 208 0.0 19.0 8 Window 2: U=0.30, S=0.27 24 0.300 7 Infiltration Htg: 2.67 Clg: 2.67 ACH50 Mechanical Equipment Heating: Fuel-fired air distribution, 64.0 kBtuh, 95.0 AFUE. Water Heating: Conventional, Gas, 0.65 EF. Cooling: Air conditioner, 28.0 kBtuh, 13.0 SEER. Required signatures vary depending upon state and or local codes, requirements and regulations. Check with your local building department to determine which signatures are required for your application. Builder or Authorized Employee I __________________________________________________ certify that the home listed above shall be built to meet or exceed all requirements of the 2015 IECC as amended by the 2016 New York State Energy Conservation Construction Code and all current energy codes specific to the local jurisdiction in which the home is built. Name - Title Signature Date Rater I, Stan Grajny, PE of GRAJNY Consulting, LLC, certify that the home listed above, as modeled meets or exceeds all requirements of the 2015 IECC as amended by the 2016 New York State Energy Conservation Construction Code and all current energy codes specific to the local jurisdiction in which the home is built. I further attest that I am a certified Home Energy Rater and affiliated with ______________________________________________ , a HERS Provider accredited by RESNET and adhering to the requirements of the Residential Energy Services Network RESNET Standards. Name - Title Signature Date Air Leakage Property Unknown 127 Burnt Hills Drive Queensbury, NY 12804 Weather:Watertown, NY 127_BurntHills MichaelsGroup_127BurntHillsQuee nsbury_041819_V.15.7.3.blg Organization GRAJNY Consulting, LLC 518-221-3240 Stan Grajny, PE Builder Michaels Group Homes Whole House Infiltration ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the 'whole-building' requirement under that version of the standard. The 62.2-2013 rate incorporates any appropriate 'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate - Residential Energy Analysis and Rating Software v15.7.3 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Confirmed 2019-04-18 Rating No:0906189 Rater ID:5609922 Duct Leakage Ventilation Blower Door Test Heating Cooling Natural ACH 0.13 0.10 ACH @ 50 Pascals 2.67 2.67 CFM @ 25 Pascals 811 811 CFM @ 50 Pascals 1272 1272 Eff. Leakage Area (sq.in) 69.8 69.8 Specific Leakage Area 0.00014 0.00014 ELA/100 sf shell (sq.in) 1.02 1.02 CFM50/sf shell 0.19 0.19 Leakage to Outside Units Ducting CFM @ 25 Pascals 5 CFM25 / CFMfan 0.0036 CFM25 / CFA 0.0015 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 8 Eff. Leakage Area (sq.in) 0.43 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0565 Mechanical Exhaust Only ASHRAE ASHRAE Adj. Sensible Recovery Eff. (%) 0.0 62.2-2010 62.2-2013 Adj. Total Recovery Eff. (%) 0.0 Rate (cfm)66 56 85 Hours/Day 24.0 24.0 24.0 Fan Watts 30.0 Cooling Ventilation Natural Ventilation INSPECTION WORKSHEET (RPLUM-001236-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0710-2018 Case Module:Permit Inspection Date:Mon Mar 4, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Rough Plumbing Job Address:Parcel Number:127 BURNT HILLS DR Queensbury, NY 12804 308.12-1-39 Contact Type Company Name Name Contractor Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Applicant Michaels Group Homes, LLC Checklist Item Passed Comments Building Inspector Notes NO 3/4/19 Plumbing Partial Approval - Pressure Test first floor only. Ok to install insulation! Remaining Items: - Pressure test plumbing in basement - Pressure test vent stack through roof. Find a location in vent stack branch line to install a dandy tee in order to install a test ball. In the future when Vent stacks are increased to the required 3" the transition needs to be done 1' below the Building Envelope. We will inspect balance of plumbing when weather permits. Plumbing Under Slab NO Mar 04, 2019 Page (1) INSPECTION WORKSHEET (RPLUM-001236-2019) Checklist Item Passed Comments Rough Plumbing / Nail Plates NO 3/4/19 Plumbing Partial Approval Remaining Items: - Pressure test plumbing in basement - Pressure test vent stack through roof. Find a location in vent stack branch line to install a dandy tee in order to install a test ball. In the future when Vent stacks are increased to the required 3" the transition needs to be done 1' below the Building Envelope. We will inspect balance of plumbing when weather permits. Plumbing Vent Vents in Place NO 3" Vent Through Roof NO 1 ½ inch minimum Drain Size NO Shower liner test (2" of water)NO Washing Machine Drain 2 inch minimum NO Washing Machine Trap: 18"-24" discharge NO Cleanout every 100 feet change of direction NO Pressure Test NO 3/4/19 Plumbing Partial Approval Remaining Items: - Pressure test plumbing in basement - Pressure test vent stack through roof. Find a location in vent stack branch line to install a dandy tee in order to install a test ball. In the future when Vent stacks are increased to the required 3" the transition needs to be done 1' below the Building Envelope. We will inspect balance of plumbing when weather permits. Drain Vent NO Mar 04, 2019 Page (2) INSPECTION WORKSHEET (RPLUM-001236-2019) Checklist Item Passed Comments Air Head NO 5 psi 5 psi or 10 ft. above highest conn. for 15 minutes NO 5psi Pressure Test NO Water Supply Piping NO Air Head NO 50 P.S.I for 15 minutes NO Air Test Gas Piping 10 psi for 10 Minutes NO All Return Air Hard Duct Work NO Duct Insulation - if required in unheated spaces NO Duct Testing Outside Conditioned Space NO Duct work sealed properly NO Mar 04, 2019 Page (3) O'Brien, John (Inspector) INSPECTION WORKSHEET (FMGAS-001239-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0710-2018 Case Module:Permit Inspection Date:Mon Mar 4, 2019 Inspection Status:Partial Pass Inspector:Gary Stillman Inspection Type:Gas Fireplace/Stove Job Address:Parcel Number:127 BURNT HILLS DR Queensbury, NY 12804 308.12-1-39 Contact Type Company Name Name Applicant Michaels Group Homes, LLC Contractor Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Checklist Item Passed Comments Fire Marshal Notes YES HEAT&GLO MODEL # SL-7 SERIAL # LC5022802 NG Building Inspector Notes YES INSTALLED IN GREAT ROOM Floor Protection YES Clearances to Combustibles (all sides)YES Firestop(s) - Vertical Chase YES VERIFIED ATTIC INSULATION SHIELD AT FIRESTOP Vent Clearance to Combustibles YES Mar 04, 2019 Page (1) INSPECTION WORKSHEET (FMGAS-001239-2019) Checklist Item Passed Comments Vent Chimney Termination YES Gas Shut-off Valve YES Combustion Air YES Hearth Extension (if any)YES N/A Mantel-height above fp opening NO RETURN TO VERIFY-SEE PAGE 57 OF INSTALLATION MANUAL FOR MANTLE CLEARANCES Witness Operation NO RETURN TO VERIFY CO Detection NO RETURN TO VERIFY CSST Bonding NO RETURN TO VERIFY Mar 04, 2019 Page (2) Stillman, Gary (Inspector) INSPECTION WORKSHEET (BINS-001303-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0710-2018 Case Module:Permit Inspection Date:Wed Mar 6, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Insulation Job Address:Parcel Number:127 BURNT HILLS DR Queensbury, NY 12804 308.12-1-39 Contact Type Company Name Name Contractor Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Applicant Michaels Group Homes, LLC Checklist Item Passed Comments Building Inspector Notes NO 3/6/19 insulation approved for first floor only. R49 in ceiling R21 in wals Window Sealing YES U Factors = .3 cfm for windows, .5 cfm for doors NO .3 for wndows Tyvek or Similar Exterior Sealant YES Proper Vent, Attic Vent NO Insulation Residential Check Commercial Check YES Blower Door Test NO Mar 06, 2019 Page (1) INSPECTION WORKSHEET (BINS-001303-2019) Checklist Item Passed Comments Combustion Air Supply for Furnace NO Fresh air supply 3' from grade NO Duct Insulation - if required in unheated spaces NO Door / Window Sealed (No Insulation)YES Air Barrier behind Knee Walls NO Tub Shower R-20 with Vapor Barrier NO All Ductwork Sealed Return and Supply NO Duct Blaster Test for duct work, R-8 NO All Return Air Hard Duct Work NO House Wrap Taped at all Seams YES Mar 06, 2019 Page (2) Smith, Mark (Inspector) INSPECTION WORKSHEET (BINS-001126-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0710-2018 Case Module:Permit Inspection Date:Tue Feb 26, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Framing Job Address:Parcel Number:127 BURNT HILLS DR Queensbury, NY 12804 308.12-1-39 Contact Type Company Name Name Contractor Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Applicant Michaels Group Homes, LLC Checklist Item Passed Comments Building Inspector Notes NO Framing NO Attic Access 22 x 30 minimum NO Jack Studs Headers NO Continuous Header for Garage Doors with Straping NO Truss Specification Provided NO Bracing Bridging NO Feb 26, 2019 Page (1) INSPECTION WORKSHEET (BINS-001126-2019) Checklist Item Passed Comments Hurricane Clips/Uplift Screws/Nail Holes Filled NO Air Seal all Plates and Sills NO Air Seal All Registers at Floor NO Air Sealing all Joints Before Insulation NO Joist hangers NO Jack Posts Main Beams NO Exterior sheeting nailed properly NO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing Walls NO Metal Strapping for Notches Top Plate NO Draft stopping 1,000 sq. ft. floor trusses NO Anchor Bolts 6 ft. or less on center NO Ice and water shield 24 inches from wall YES 2/26/19 ice & water shield approved Soffits-Insulation Baffel NO Windows Habitable Space Bedrooms NO Feb 26, 2019 Page (2) INSPECTION WORKSHEET (BINS-001126-2019) Checklist Item Passed Comments 24 in. (H)NO 20 in. (W)NO 5.7 sf above below grade NO 5.0 sf grade NO Design Professional Sign-off, if required NO Feb 26, 2019 Page (3) Smith, Mark (Inspector) INSPECTION WORKSHEET (BINS-000415-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal RC-0710-2018Permit Case Number:Case Module: Thu Jan 17, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Foundation Inspector:Inspection Type: 127 BURNT HILLS DR308.12-1-39 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName Granted PermissionMichaels Group Homes, LLC Primary OwnerMichaels Group Homes, LLC ContractorMichaels Group Homes, LLC ApplicantMichaels Group Homes, LLC Checklist ItemPassedComments Building Inspector NotesNO1/17/19 Backfill, Dampproofing, and Perimeter Drain Approved FootingsYES2 rows of #4 continuous. Wet sticking verticals PiersNO Monolithic SlabNO Reinforcement in PlaceNO Foundation / WallpourYES1/14/19 with one row # 4 continuous tow Footing Drain Daylight or SumpNO Jan 17, 2019Page (1) INSPECTION WORKSHEET (BINS-000415-2019) Checklist ItemPassedComments Footing Drain stone - 6 mil polyNO Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorNO Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabNO O'Brien, John (Inspector) Jan 17, 2019Page (2) CEDWIE0 REScheck Software Version 4.6.5 41 Compliance Certificat NOV 09 2018 TOWN OF QUEENSBURY B ODES Project The Hawthorn (/\ ()��o Rup to Energy Code: 2015 IECC 1 Location: Glens Falls, New York * r . .4' Construction Type: Single-family r �� 'r" rr `�-: Project Type: New Construction cw - "'v' ' / coa N Conditioned Floor Area: 1,681 ft2 Lto ',..43 `<$.`i / N Glazing Area 16% �•- d Climate Zone: 6 (7635 HDD) �_ `� . O V Permit Date: 5 November, 2018 ~ J as Permit Number: V In Construction Site: Owner/Agent: Designer/Contr.ctor: II E 6 127 Burnt Hills Drive Michaels Group Homes, LLC 0 Queensbury, NY 12804 1 Marions Way I i CO Mechanicville, NY 12118 C.(Q z 0- CA ompliance:Passes using UA trade-off M CA -1-. M Compliance: 4.7%Better Than Code Maximum UA: 276 Your UA: 263 r .m E. •The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. N CO r It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. r .cIb Q Ca Ca) Envelope Assemblies `') Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling: Raised or Energy Truss 1,681 38.0 0.0 0.025 42 Walls: Wood Frame, 24" o .c. 1,674 21.0 0.0 0.056 77 Entry#1: Solid 21 0.170 4 2x Bed #2 (AV): Vinyl Frame:Double Pane with Low-E 33 0.300 10 lx Bath (AA):Vinyl Frame:Double Pane with Low-E 5 0.300 2 lx Home Office(H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 lx Dining (BL): Vinyl Frame:Double Pane with Low-E 8 0.300 2 2x Dining (B):Vinyl Frame:Double Pane with Low-E 20 0.300 6 Dining #7: Glass 40 0.330 13 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9 lx Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8 2x Master Bed (B):Vinyl Frame:Double Pane with Low-E 20 0.300 6 lx Master Bed (AD):Vinyl Frame:Double Pane with Low-E 29 0.300 9 lx Master Bath (AM): Vinyl Frame:Double Pane with Low-E 7 0.300 2 Mud #20: Solid 19 0.170 3 Basement Walls: Solid Concrete or Masonry 1,413 0.0 19.0 0.039 54 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 1 of10 Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter 2x Std Basement Windows: Wood Frame:Double Pane with Low-E 4 0.300 1 lx 5030 Sliding Window: Wood Frame:Double Pane with Low-E 15 0.300 5 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has be signed t eet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed he RESc Inspection Checklist. f/7/8' Name-Title Signature Date j)/ Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 2 of10 REScheck Software Version 4.6.5 Inspection Checklist I Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and DComplies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies I103.2, documentation demonstrate ❑Does Not '403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable 11 Systems serving multiple ❑Not Applicable dwelling units must demonstrate I compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies '403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr ❑Not Applicable approved by the code official. PP I l Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ; 3 1Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions 1& Req.ID 1402.1.1 Conditioned basement wall R- R- Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R- R EDoes Not table for values. insulation is used, verification may need to occur during ElNot Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per EDoes Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or EDoes Not table for values. distance from top of wall. :Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior EDoes Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12)2 controls installed. EDoes Not t. ❑Not Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 4 of10 Section Plans Verified Field Verified # Framing I Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ENot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ENot Observable [FR2]1 ENot Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ENot Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ENot Observable 400 that do not exceed code :Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 52.0 cfm leakage at 75 Pa. :Not Observable ENot Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ENot Observable return ducts in other portions of ENot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15)3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to >_R- 3 ENot Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR2411 piping. ❑Does Not 41: ['Not Observable _ ENot Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ENot Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ['Not Observable ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 5 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled EComplies [IN13]2 or the installed R-values ❑Does Not provided. ['Not Observable ❑Not Applicable I,402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 1402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ENot Observable [IN3]1 exterior, the exterior insulation *2. ❑ Steel ❑ Steel ENot Applicable requirement applies(FR10). 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ENot Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood Does Not table for values. 402.2.2, 402.2.E ❑ Steel ❑ Steel [Not Observable [FI1]1 :Not Applicable 303.1.1.1, Ceiling insulation installed per Complies 303.2 manufacturer's instructions. Does Not [F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ENot Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_ R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 ach in Climate Zones 1-2, and EDoes Not <=3 ach in Climate Zones 3-8. ['Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ['Not Observable handler @ 25 Pa. For rough-in tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a [Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. i !403.3.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ['Not Observable :Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ['Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies j[FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11)2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 8 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system EComplies [FI2512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ENot Observable ENot Applicable 403.2 Hot water boilers supplying heat EComplies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback ENot Observable control to lower boiler water temperature based on outdoor ENot Applicable temperature. 403.5.1.1 Heated water circulation systems EComplies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ENot Observable pipe. Gravity and thermos- ENot Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems EComplies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ENot Observable heat tracing to maintain the ENot Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that EComplies [FI30]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ENot Observable water source through a cold ENot Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units EComplies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ENot Observable recovery units< 3 psi for ENot Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent EComplies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ENot Observable lighting. ENot Applicable 404.1.1 Fuel gas lighting systems have EComplies [F12313 no continuous pilot light. ❑Does Not ENot Observable ENot Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 'Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID '401.3 Compliance certificate posted. EComplies i[FI7]2 ❑Does Not [Not Observable :Not Applicable 1303.3 Manufacturer manuals for EComplies [FI18]3 mechanical and water heating Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Hawthorn Report date: 11/05/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\16 Wooden Lane.rck Page 10 of10 20r44. 15 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.33 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments v Nov 49 2018 I U TOWN OF QUEENSBURY ?UILUING&CODES F_f 127 Burnt- s r HVAC Load Calculations for The Michaels Group 1T I 2 ' __ _ RESIDENTIAL, HVAC LOADS 308.12-1-39 RC-0710-2018 Michaels Group Homes LLC 127 Burnt Hills Dr SFD w/gas FP 1681 s.f., Gar. 466 s.f. Prepared By: Nick Abrunza Appolo Heating 868 Burdeck St Schenectady Ny 12306 Wednesday,November 07,2018 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,`Inc. Appal()Heating Inc. 127 Burnt Hills Dr Schenectady,:NY 12306 Page 2 Project Report EGeneraLPiO eci=tnfor.ation. i . ' v-.` . .,,,; : _ '' Project Title: 127 Burnt Hills Dr • Designed By: The Michaels Group Project Date: Wednesday, November 07, 2018 Client Name: The Michaels Group Company Name: Appolo Heating Company Representative: Nick Abrunza Company Address: 868 Burdeck St Company City: Schenectady Ny 12306 [Des grt'Data _ ' "/�y, ' t, ' r �>> ; . - {d 'S a'�a-9'P. _6+Y - d.� vir2.SY. ?4'. Reference City: Schenectady, New York Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 1 ) Outdoor Outdoor Outdoor Indoor Indoor Grains I Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a t Summer: 87 72 49% 50% 75 30 Check Fig ores . =.tip ? `4 A `� `_ H Total Building Supply CFM: 1,026 CFM Per Square ft.: 0.300 r. Square ft. of Room Area: 3,414 Square ft. Per Ton: 1,648 t Volume (ft3): 30,728 Budding.Loads . . ,. .- ;t k 1 :i , ; ___ Total Heating Required Including Ventilation Air: 52,991 Btuh 52.991 MBH • a Total Sensible Gain: 22,264 Btuh 90 % 1 Total Latent Gain: 2,594 Btuh 10 % Total Cooling Required Including Ventilation Air: 24,858 Btuh 2.07 Tons (Based On Sensible+ Latent) o �__ - NOtes ;'� •-,' F., ,Li.,--"As 0. _. U1% --; q Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. a All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at I your design conditions. i L s i i • C:\...\127 Burnt Hills Dr.rh9 Wednesday, November 07,2018, 8:53 AM I ( I Rhvac-Residential&Light Commercial HVAC Loads • Elite Software Development,Inc.` a Appolo Heating Inc. 127 Burnt PageHillsr I. 3 I. Schenectady,NY 12306 i Miscellaneous Report r{ y� ohs (p V . 9i yr - J .s,,,., e2b J ` .., '"� --'4r s. ,,[ 3 ir���"�d`�a���ti �� ..� ,�. 4 a X�� a ��aat� ,C"��, e1� ����.. � SY'.. .. � a"'� �xl��-P..'. I Winter: 1 0.31n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 q Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. I Maximum Height: 0 in. 0 in. OutSfde:Alr Da a,. i'6;' '. V ?:aw r-h z+�'P.e'- s ' ,4 ' "., P'a 4iar...,* �:Y rA.x a is :' .$'s .>` 'fi; } Winter Summer Infiltration Specified: 0.280 AC/hr 0.150 AC/hr 143 CFM 77 CFM Infiltration Actual: 0.280 AC/hr 0.150 AC/hr Above Grade Volume: X 30,728 Cu.ft. X 30.728 Cu.ft. 8,604 Cu.ft./hr 4,609 Cu.ft./hr r X 0.0167 X 0.0167 Total Building Infiltration: 143 CFM 77 CFM Total Building Ventilation: 0 CFM 0 CFM it s ---System 1--- w Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr(143 CFM), Construction:Average Summer Infiltration Specified: 0.150 AC/hr(77 CFM), Construction:Average 1 I 'i a P ai 3 " i 1 it . i I c i C:1...1127 Burnt Hills Dr.rh9 Wednesday, November 07, 2018, 8:53 AM E2hvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. • 127 Burnt Hills Dr Schenectady,NY 12306 Pape 4 Load Preview Report Net ft.' Senl La Net Seri Min n Clg Hts Cls Act Duct Scope Tor /Tor Are GN Gai Gair Loss 9 9 9 Size � CFM CFM CFM CFM CFM Building 2.07 1,648 3,414 22,264 2,594 24,858 52,991 698 1,026 698 1,026 1,026 System 1 2.07 1,648 3,414 22,264 2,594 24,858 52,991 698 1,026 698 1,026 1,026 12x15 Zone 1 3,414 22,264 2,594 24,858 52,991 698 1,026 698 1,026 1,026 12x15 1-Basement 1,681 2,739 702 3,441 18,143 239 126 239 126 126 2-5 2-Master Bedroom 255 3.138 839 3,977 5,508 73 145 73 145 145 2--5 3-WIc 63 640 30 670 1,089 14 30 14 30 30 1-4 4-Master Bath 117 1,424 95 1,519 2,850 38 66 38 66 66 1-5 5-Laundry/Mud Room 78 1.074 35 1,109 1,599 21 49 21 49 49 1-4 6-Great Room 423 2,945 78 3,023 6,265 82 136 82 136 136 2-5 7-Dining 156 1,926 113 2,039 4,305 57 89 57 89 89 1-6 8-Kitchen 166 1.394 51 1,445 2,391 31 64 31 64 64 1-5 9-Home Office 146 2.320 49 2,369 2,746 36 107 36 107 107 1-6 10-Bath 1 69 919 27 946 1,233 16 42 16 42 42 1-4 11-Bedroom 2 171 2,628 516 3,144 4,878 64 121 64 121 121 2-4 4 12-Foyer 90 1,120 59 1,179 1,984 26 52 25 52 52 1-4 4 4 1 4 C:\...\127 Burnt Hills Dr.rh9 Wednesday, November 07,2018, 8:53 AM 1 l I t Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 111 127 Burnt Hills Dr i Schenectady,NY 12306 Page 5 Duct Size Preview i Room or Source Minimum Maximum Rough Desk' Si Duct Duct Htg Clg Act. Duct Duct Name Velocity Velocity Factor L/10q Los Velocity Length Flow Fbw Flow I Size y a System 1 Supply Runouts i Zone 1 I 1-Basement Built-In 450 750 0.01 0.1 462.8 239 c 126 2-5 2-Master Bedroom Built-In 450 750 0.01 0.1 530.2 73 F_' ! 145 2-5 i 3-W1c Built-In 450 750 0.01 0.1 338.1 14 _.wF: 30 1-4 , 4-Master Bath Built-In 450 750 0.01 0.1 481.2 38 .,r 66 1-5 ' 5-LaundryMtud Room Built-In 450 750 0.01 0.1 567.1 21 `` 49 1-4 6-Great Room Built-In 450 750 0.01 0.1 497.6 82 f; 136 2-5 i 7-Dining Built-In 450 750 0.01 0.1 451.9 57 , : 89 1-6 i8-Kitchen Built-In 450 750 0.01 0.1 470.9 31 l 64 1-5 9-Home Office Built-In 450 750 0.01 0.1 544.4 36 I[If! 107 1-6 10-Bath 1 Built-In 450 750 0.01 0.1 485 16 ;;'-'• 42 1-4 11-Bedroom 2 Built-In 450 750 0.01 0.1 693.7 64 4 I, 121 2-4 12-Foyer Built-In 450 750 0.01 0.1 591.4 26-L_Y_.,.'i 52 1-4 If Other Ducts In System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 820.7 698 t;t 1,026 12x1t i Summary __ __ System 1 b Heating Flow: 698 1 Cooling Flow: 1026 i i i i k r I t 't i I 1 0 i 1 1 i 1 1 i 1 i i a} t I x I i 1 1 C:\...\127 Burnt Hills Dr.rh9 Wednesday, November 07, 2018, 8:53 AM • • Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 127 Burnt Hills Dr Schenectady,NY 12306 le Page 6 i Total Building Summary Loads Component # a} x -: .A `.. fi h,-,7 „y - r a I l:)..escnption _, 13 ,§;s...,.r , 4't'3ll .s,,, W. a£tfrf+ 8. . si W F- 1 Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 209.2 4,474 0 3,093 3,093 4 Fire Rated: Door-Fire Rated 20.4 394 0 131 131 1 Pella Slider: Door-Slider 40.8 845 0 282 282 Front Door TMG: Door-TMG Entry U-Value 0.19 20.4 267 0 89 89 12E-0bm: Wall-Frame, R-19 insulation in 2 x 6 stud 1458 10,362 0 1,261 1,261 t cavity, no board insulation, brick finish, metal studs i 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1457.9 6,536 0 1,164 1,164 cavity, no board insulation, siding finish, wood studs 166-38: Roof/Ceiling-Under Attic with Insulation on Attic 1733.3 3,108 0 2,120 2,120 t Floor(also use for Knee Walls and Partition i Ceilings), Vented Attic, No Radiant Barrier, Dark t Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation t 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1681 2,900 0 0 0 or more feet below grade, no insulation below floor, t any floor cover, shortest side of floor slab is 24'wide 19A-Ocp: Floor-Over enclosed crawl space, No insulation 1547 11,829 0 2,058 2,058 on exposed walls, sealed or vented space, passive, no floor insulation, carpet or hardwood 19A-Otp: Floor-Over enclosed crawl space, No insulation 186,3 1,540 0 268 268 t on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl 1 Subtotals for structure: 42,255 0 10,466 10,466 People: 3 1,050 1,350 2,400 Equipment: 0 0 0 Lighting: 2770 9,446 9,446 4, Ductwork: 0 0 0 0 t Infiltration: Winter CFM: 143, Summer CFM: 77 10,736 1,544 1,002 2,546 t Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 52,991 2,594 22,264 24,858 Check Figures e ,, '41 .i __ ' ___<' Total Building Supply CFM: 1,026 CFM Per Square ft.. 0.300 Square ft. of Room Area: 3,414 Square ft. Per Ton: 1,648 Volume(ft3): 30,728 '''''.'-Cr _, > ram , Buildin toads ' l, ' ,r m s ': 'Wr`r Total Heating Required Including Ventilation Air: 52,991 Btuh 52.991 MBH Total Sensible Gain: 22,264 Btuh 90 /o Total Latent Gain: 2,594 Btuh 10 % Total Cooling Required Including Ventilation Air: 24,858 Btuhh 2.07 Tons(Based On Sensible+Latent) i' oteS,- : ...; .,_ 5 : ,- _ �"'.;�=�uc-. 'r, p . .cz+:i a'°"rm -4K,' ,�..,. z2' Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. ; All computed results are estimates as building use and weather may vary. l Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. a "A E i 1 1 1 i. C:\...\127 Burnt Hills Dr.rh9 Wednesday, November 07, 2018, 8:54 AM t I g I 'Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. lit 127 Burnt Hills Dr Schenectady,NY 12306 PaOe 20' i [-System 1 Room Load Summary 4,i 74ao `'' i, F --�- 1 c F g ee t o 'n a alit,- A� ---Zone 1--- 1 1 Basement 1,681 18,143 239 2-5 463 2,739 702 126 126 2 Master Bedroom 255 5,508 73 2-5 530 3,138 839 145 145 3 Wlc 63 1,089 14 1-4 338 640 30 30 30 4 Master Bath 117 2,850 38 1-5 481 1,424 95 66 66 5 Laundry/Mud 78 1,599 21 1-4 567 1,074 35 49 49 Room 6 Great Room 423 6,265 82 2-5 498 2,945 78 136 136 7 Dining 156 4,305 57 1-6 452 1,926 113 89 89 8 Kitchen 166 2,391 31 1-5 471 1,394 51 64 64 9 Home Office 146 2,746 36 1-6 544 2,320 49 107 107 10 Bath 1 69 1,233 16 1-4 485 919 27 42 42 1 11 Bedroom 2 171 4,878 64 2-4 694 2,628 516 121 121 12 Foyer 90 1,984 26 1-4 591 1,120 59 52 52 System 1 total 3,414 52,991 698 _ 22,264 2,594 1,026 1,026 System 1 Main Trunk Size: 12x15 in. u Velocity: 821 ft./min t Loss per 100 ft.: 0.103 in.wg ' Cgoll t `stem Sum '' ''-7- _ ,� 4 -- .t, , i= 4a , -tent -nsible 3 -. y i xi "'._ !,.^ pat Btuh _ - . • E; ' t � 4 Net Required: 2.07 90%/10% 22,264 2,594 24,858 f Actual: 2.48 75%/25% 22,350 7,450 29,800 .� .4. _ _" ems; r�s�:s7+t sir � �:"y ,� :.�� .x f , a ut a rrlent. .. i i^ -* :•`..} 'S 3 ,, �r`;' `'.J.c'"„>,"'� �„:a 3'5 .,.,., .. . >� ' - . ,.m . . :�•:ti Rg 2 Heating System Cooling System g Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B* 13ACXN030-230-** b Indoor Model: C35-36B+TDR+TXV Brand: MERIT 90 LENNOX Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 15 SEER Sound: 0 0 Capacity: 64,000 Btuh 29,800 Btuh 1 Sensible Capacity: n/a 22,350 Btuh i Latent Capacity: n/a 7,450 Btuh AHRI Reference No.: n/a 8267093 i i i f t y i I 1 E f 1 i C:\...\127 Burnt Hills Dr.rh9 Wednesday, November 07, 2018, 8:54 AM INSPECTION WORKSHEET (BINS-001126-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0710-2018 Case Module:Permit Inspection Date:Tue Feb 26, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Framing Job Address:Parcel Number:127 BURNT HILLS DR Queensbury, NY 12804 308.12-1-39 Contact Type Company Name Name Contractor Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Applicant Michaels Group Homes, LLC Checklist Item Passed Comments Building Inspector Notes NO Framing NO Attic Access 22 x 30 minimum NO Jack Studs Headers NO Continuous Header for Garage Doors with Straping NO Truss Specification Provided NO Bracing Bridging NO Feb 26, 2019 Page (1) INSPECTION WORKSHEET (BINS-001126-2019) Checklist Item Passed Comments Hurricane Clips/Uplift Screws/Nail Holes Filled NO Air Seal all Plates and Sills NO Air Seal All Registers at Floor NO Air Sealing all Joints Before Insulation NO Joist hangers NO Jack Posts Main Beams NO Exterior sheeting nailed properly NO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing Walls NO Metal Strapping for Notches Top Plate NO Draft stopping 1,000 sq. ft. floor trusses NO Anchor Bolts 6 ft. or less on center NO Ice and water shield 24 inches from wall YES 2/26/19 ice & water shield approved Soffits-Insulation Baffel NO Windows Habitable Space Bedrooms NO Feb 26, 2019 Page (2) INSPECTION WORKSHEET (BINS-001126-2019) Checklist Item Passed Comments 24 in. (H)NO 20 in. (W)NO 5.7 sf above below grade NO 5.0 sf grade NO Design Professional Sign-off, if required NO Feb 26, 2019 Page (3) Smith, Mark (Inspector)