Loading...
SOLAR-0736-2018 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-0736-2018Date Issued: Thursday, January 17, 2019 This is to certify that work requested to be done as shown by Permit Number SOLAR-0736-2018 has been completed. 297.10-1-45 Tax Map Number: 28 WINCOMA DR Location: PAUL DESLAURIERS Owner: Apex Solar Power Applicant: This structure may be occupied as a: Solar Panel Installation By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building & Code Enforcement Planning Board or Zoning Board of Appeals. jA TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: SOLAR-0736-2018 Tax Map No: 297.10-1-45 Permission is hereby granted to: PAUL DESLAURIERS For property located at: 28 WINCOMA DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: PAUL DESLAURIERS Solar Panel-Residential $27,825.00 Owner Address: 28 WINCOMA DR Total Value $27,825.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Demarse Electric 64 MAIN ST Queensbury,NY 12804 Plans&Specifications Solar Panel Installation $ 75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday,November 26,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town ue bury; �J Mo s:y !: • = ber 26,2018 �VJ SIGNED BY: V \ for the Town of Queensbury. Director of Building&Code Enforcement • Office Use Only .. t Permit#: �(1�. -l-t -7 JCOI Fee: $ 742 Bay Road,Queensbury, NY 12804 Invoice#: 16�S P:518-761-8256 www.queensbury.net SOLAR PANEL PERMIT APPLICATI"Cif [ C E ll v 1111• Property Owner(s): NOV 2 0 2018 Name(s): en LA Desi_nutrierS• TOWN OF QUEENS Mailing Address, C/S/Z: 2S .4l))!1[UMa Drove; r 2- ES Cell Phone: _( ) Land Line: _( $oz ) SlEs—fc7oc Email: Project Address: 251 lA3nc.u.N,c4 fr)Je. Section Block Lot: t47. to l 4S Existing Use: ►:i Single Family 0 2-4 Family 0 Commercial 0 Other: • Solar Contractor: Business Name: Nmar:se DBA Gt¢ex Solar Power Contact Name: C A. Alrnelr)a' Mailing Address, C/S/Z: LA Main S4-reel-\Q:A.eens5ur1 N'? t2 04 Cell Phone: _( ) Land Line: ( Sits ) 3c —27k, Email: • Electrical Contractor: Business Name: Sane, as abd•.re. Contact Name: Mailing Address, C/S/Z: Cell Phone: _( ) Land Line: _( ) Email: Contact Person for Building & Code Compliance: i4,n,efr fc_ _ (apex Sofa Po er) Cell Phone: ( ) Land Line: ( sift ) 3o'1— 2--03.19 Email: Solar Panel Application Revised December 2017 Estimated cost of construction: $ qzs. Total System Capacity Rating (sum of all panels): Solar PV System: 9,ti kW DC Select System Configuration: *Please see u egi Se4-Q[cins, ❑ Supply side connection with micro inverters ❑ Supply side connection with DC optimizers ❑ Supply side connection with string inverter ❑ Load side connection with DC optimizers ❑ Load side connection with micro inverters ❑ Load side connection with string inverter Please sign below to affirm that all answers are correct and that you have met all the conditions and requirements to submit a unified solar permit. *(lease See 0.44-aecAed clu4wrd2er-f Qn form. Homeowner's Signature Date C k1 rvimi 1 Cal e.A-/ atcf-x Bahr Power) t fzed ts' Solar Co. Representative Signature Date Solar Panel Application Revised December 2017 f�a�\ DC SI OW ��cf • • • • •: im • • •:• • • • • •• • • •••• ••• • • • • • • apex'TM AUTHORIZATION FORM "TO ACT AS AGENT FOR" I, ?au\ Dec i rurierc owner of the premises located at: 2k E19anc.oahy.4 Dr1Jc Town of Cueensbur►i Tax Parcel # Zcr�1, i 0- hereby designate: Q Dex Salat Parer as my AGENT regarding my Permit Application for: R acre moW► so ICU' fr4PI r4S-1-en+, / / / . Date Signature • r v PHOTOVOLTAIC SYSTEM D L ' C� t q vED EQUIPMENT: SYSTEM SIZE: PV MODULES: (33)TRINA TSM300DDO5A.05(II) INVERTER(S): (1)SE10000H-US DC/AC kW STC: 9.9kW 1 10kW /n Q TOWN OF NOV'v a `O�V SCOPE OF WORK: BUILD NG DEPARTMENT INSTALLATION OF A SAFE AND CODE-COMPLIANT Ba :• on our li ited examination,compliance TOWN 01=QDEENSBURY GRID-TIED SOLAR PV SVSTEM. with •ur comm:nts shall not be construed as BUILDING& CODES indilating the •ans and specifications are in full ►mplianc LNith the Building Codes of a 297.10-1-45 Ne fork St SOftil LAR-0736-2018 DesLauriers, Paul 28 Wincoma Dr Solar Panel Installation Z W1P J YES NOI :II POST INSTALL SUNEYES REQUIRED? r: 1 APPLICABLE CODES: 0 2015 IRC CODE Z 2014 NAT UNIFORM C RIC L COLEMENT 2014 NATIONAL ELECTRICAL CODE � SHEET INDEX ai F ILE COPY PV-01 COVER AND PLOT PLAN PV-02 SITE PLAN,STRINGS,BOM TOWN OF QUEENSBURY PV-03 MODULE LAYOUT PV-04 THREE-LINE DIAGRAM BUILDING & COD n T. Reviewed iB SITE PLAN Date: SCALE N.T.S. $11) ` ` REVISION NOTES: DRAWN PROJECT NAME CLIENT [SCALE: 64 Maim Bred REV REV BY DATE DESCRIPTION BY: DATE: DESLAURIERS-420856 DESLAURIERS.PAUL Qarw�bay,NY 12804RQR 10/2212016 ROOF MOUNT 28 WINCOMA DR P�PbAtiM 1tX+vev.enowi wn..wn..tw�+l4408 •800 WATTS OUEENSBURY,NY 12804 DRAWING ala(apemol9Pow'a.com BY: DATE: 802-578-8705 NUMBER: (sl•}70•-2746 DRAWING TITLE: COVER AND PLOT PLAN PV-01 KEY PROPERTY LINE El SUBPANEL CONDUIT RUN ❑a DC DISCONNECT DRIVEWAY SOLAR MODULE "❑�O AC DISCONNECT n MAIN SERVICE PANEL®®JUNCTION BOX El UTILITY METER ❑�'MONITORING UNIT Q PV METER COMBINER BOX ROOF OBSTRUCTION CUSTOMER INITIALS: STRING 1 AC DISCONNECT 10 MODULES INVERTER 1 MAIN SERVICE PANEL INPUT 1 UTILITY METER SUB PANEL 1 o a AC DISCONNECT STRING 3 --- 13 MODULES INVERTER 1 INPUT 3 e / NOTES: STRING 2 1. BOS TO BE LOCATED EXTERNALLY ON NORTHERN 10 MODULES SITE PLAN DETAIL WALL NEXT TO EXISTING MAIN SERVICE PANEL INVERTER 1 SCALE N.T.S. 2. CONDUIT SHOULD BE RUN PARALLEL TO EXISTING INPUT 2 WHENEVER POSSIBLE. ^ 1 REVISION NOTES: DRAWN DATE: PROJECT NAME CLIENT: SCALE: 64 Maio Siren' REV REV BY DATE D€SCRIP17ON DESLAUR(ERS-420856 OESLAURIERS.PAUL Qpecnebury,NY 12804 - _-- - RCM 10/22/201S ROOF MOUNT 29 WINCOMA DR D:GDrWSWnoCADWper Soler Power Horizontal lopo.gp -- CHECK ' 9900 WATTS OUEENSBURY,NY 12804 ORANRVO BY: DATE: 802-57E2705 NUMBER: a1a(,apexeolarrower,corn (518)-109-2786 — -- DRAWING TITLE: SITE PLAN.SOM,NOTES 141 .., A • • ,a KEY • PROPERTY LINE ElSUBPANEL CONDUIT RUN 0 DC DISCONNECT DRIVEWAY SOLAR MODULE 0 AC DISCONNECT MAIN SERVICE PANEL®®UNCTION BOX 0 UTILITY METER 0 MONITORING UNIT Q PV METER n❑COMBINER BOX ROOF OBSTRUCTION CUSTOMER INITIALS: ACCESS PATHWAY(36-) E VENTILATION ACCESS(18') if ACCESS PATHWAY(36') FIRE PLAN DETAIL SCALE: N.T.S. REVISION NOTES: DRAWN DATE: PROJECT NAML. CLIENT: SCALE: 64 Main Street REV REV BY DATE DESCRIPTION BY: DESlMJR1ER5-420856 DESLAURIERS,PAUL OINensbury.NY 12N04 RGR 10/22/2015 ROOF MOUNT 28 WINCOMA DR D:\GDrIaANDCADIAN6 SoW Pony I4OWoMMINK41) CHECK WOO WATTS OUEENSBURY.NY 1 804 DRAWING DATE: aIN0apncaolupower.wm BY: 802-578-8705 NUMBER: /518r309-2786 DRAWING TITLE: SITE PLAN,SOM,NOTES 1,- " �' 32'-2" " ROOF SPECS / Y 1'- RAFTER SIZE: 2x4 • 33'-32" NQ RAFTER SPACING(in): 24 ROOF MATERIAL: ASPHALT ARRAY SPECS ® ® ® ® ® ® ® ® ® TILT('): 36 AZIMUTH(°): 102 SQUARE FEET(k2) 370 ® ® ® ® 0 0 0 0 0 N i0 0 0 0 0 0 0 0 0 0 0 0 ® 0 ® ® ® ® ® ® ® ® ® ® ® 0 ® ® ® �IQ q IN d ® 0 ® snv____....---J ()MOUNTING DETAIL SCALE: NTS ()ARRAY LAYOUT - ROOF 1 CD ARRAY SCALE: NTS Solar Module N IronRidge XR-100 Rd / L-Foot Flashing-Low Profile Composite Shingl 5/16"LAG (Minimum 2.5"thread penetration) REVISION NOTES: DRAWN DATE: PROJECT NAME: CLIENT: SCALE: 64 Main Street REV REV BY DATE DESCRIPTION BY: DESLAURIERS-420856 DESLAURIERS,PAUL Queensbury,NY 12804 RGR 10/22/201E ROOF MOUNT 28 WINCOMA DR mtoon..wmKa. wa*ttaseroe.wra CHECK 11900 WATTS QUEENSBURY,NY 12804 DRAWING Bti: DATE: sales(aapexntaspowerunen 802-578-8705 NUMBER, (518}309.2786 l DRAWING TITLE: — I— at a ' INVERTER LABELS-ONE FOR EACH INPUT PHOTOVOLTAIC AC DISCONNECT MODULE ELECTRICAL SPECIFICATIONS INVERTER SPECIFICATIONS DESIGN CONDITIONS ELECTRICAL KEY: ALL SOLAREDGE INPUTS MAXIMUM AC OPERATING CURRENT 42A (33)TRINA TSM300DDO5A.05(II) SOLAREDGE SE10000H-US HIGHEST 2%DB DESIGN TEMP('C): 31 -e.M.- BREAKER Vopp=350V NOMINAL OPERATING AC VOLTAGE 240V SHORT CIRCUIT CURRENT(Mc): 9.64 RATED WATTS(EACH): 10000 MIN.MEAN EXTREME ANNUAL DB(*Cr -29 -/- SWITCH vmax=500v OPEN CIRCUIT VOLTAGE(Voc): 39.9 AC OPERATING VOLTAGE(V): 240 O SCREW TERMINAL INPUTS WITH NO STRING COMBINATIONS OPERATING CURRENT(IMP). 9.18 AC OPERATING CURRENT(A): 42 m FUSE • SPLICE lopp=8.5A OPERATING VOLTAGE(VMP) 32.7 NUMBER OF MPPT CHANNELS 2 lirEARTH GROUND Ix=11.25A INVERTER EFFICIENCY: 99 m CHASSIS GROUND INPUTS WITH(2)STRING COMBINATIONS INTEGRATED DC DISCONNECT GEC lope=17A EGC II0=22.5A (6)#10 PV-Wire (3)#6 THHN (6)#10 THHN (3)#6 BARE GRD (1)#6 THHN GRD (3)#6 THHN (3)#4 THHN Al FREE AIR (3)#6 THHN GRD 3/4"EMT (1)#6 THHN GRD (1)#6 THHN GRD 3/4"EMT 3/4"EMT 1"EMT �� METER AC DISCONNECT ALL PANELS EQUIPPED WITH (1)SOLAREDGE SE10000H-US AC DISCONNECT 60AMP SERVICE SOLAREDGE P320 POWER NEMA 3R INVERTER W/INTEGRATED 60AMP SERVICE RATED FUSABLE OPTIMIZERS SOLADECK DC DISCONNECTS RATED NON-FUSIBLE (2)-60A FUSES r_. _ / --- PIERCING TAPS pINPUT 1 L7 -- — r STRING 1 * JI 10 MODULES o ) �DC OUTPUT 1. — LOAD LINE LOAD UNE 1I V- / 200AMSP I / za0v fo- _____ INPUT2 i STRING 2 4 --- --y -�� /"/'� 200A MAIN BREAKER 10 MODULES t\--t\. to (E)LOADS INPUT 3 0 STRING2 9I-- --T -�DC 13 MODULES If m (E)LOADS INVERTER / GEC IRREVERSIBLY SPLICED j / TO EXISTING GEC OR BONDED CELLULAR —/ DIRECTLY TO EXISTING COMM.KIT GROUNDING ELECTRODE CONDUIT ELEVATION:1/2 TO 3-1/2"=22°C HIGH AMBIENT TEMPERATURE:31°C 200 x 1.2=240 EXTREME LOW:-29°C 240-200(MCB)=40A SOLAREDGE SE10000H-US MAX CURRENT=32A ROOFTOP AMBIENT TEMP:53°C=0.76 MAX ALLOWABLE AC PV BREAKER=40A MAX DESIGN CURRENT=32A X 1.25=40A=40A BREAKER/FUSES CONDUIT FILL:1 1 - - REVISION NOTES: DRAWN PROJECT NAME: CLIENT: (SCALE: 64 Main Soon BY: DATE: Qaeembpry.NY 12804 REV REV BY . DATE DESCRIPTION - - DESLAURIERS-420856 DESLAURIERS.PAUL 6660 Joy Road ROOF MOUNT 28 WINCOMA DR cw'.....y'13........4....°"......`ni9 PAN Syracuse.NY 13057 Ll EM 9900 WATTS DUEENSBURY,NY 12804 DRAWING BY: �� 902579-8705 • NUMBER: p(a glapexsolarpower.com (518)-309-2786 DRAWING TITLE: — — Mono Multi Solutions 1 _- __ THE AXPLU sf I FRAMED 60-CELL MODULE 60 CELL MONOCRYSTALLINE MODULE 275-315W POWER OUTPUT RANGE . .. 19.2% MAXIMUM EFFICIENCY Maximize limited space with top-end efficiency -ti" •Up to 192W/mx power density •Low thermal coefficients for greater energy production at high 0^r 5 • operating temperatures POSITIVE POWER TOLERANCE ����"� Highly reliable due to stringent quality control Founded in1997,TrinaSolar is the worlds leading T 0 •Over 30 in-house tests(UV,TC,HF,and many more) comprehensive solutions provider for solar energy. •In-house testing goes well beyond certification requirements we believe close cooperation with our partners is •PID resistant critical to success.Trina Solar now distributes its •100%EL double inspection PV products to over 60 countries all over the world.Trina is able to provide exceptional service • Selective emitter,advanced surface texturing to each customer in each market and supplement our innovative,reliable products with the backing of Trina as a strong,bankable partner.We are committed to building strategic,mutually Certified to withstand the most challenging beneficial collaboration with installers,developers, environmental conditions distributors and other partners. •2400 Pa wind load •5400 Pa snow load Comprehensive Products •35 mm hail stones at 97 km/h And System Certificates IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001:Quality Management System ISO 14001:Environmental Management System 15014064:Greenhouse gases Emissions Verification OHSAS 18001:OccupManagement alth ystemdSafety LINEAR PERFORMANCE WARRANTY Management System .- 10 Year Product Warranty•25 Year Linear Power Warranty '�••. 97a/o Addi 0 — rrs,4 ;.ate PV'CYCLE•\ ______ 2Zt17 WV d 90% Donal value from Trina Solars linear warranty c Years 5 10 15 ?5 Trina So Ia r •Trina Linear Warranty Standard Step Warranty e ALLMAX©pus' FRAMED 60-CELL MODULE ° PRODUCTS POWER RANGE ELECTRICAL DATA(STC) TSM-DDOSA.08(II) 280-315W TSM-DDO5A.05(II) 275-310W Peak Power Watts-PMnx(Wp)' 275 280 285 290 295 300 305 310 315 Power Output Tolerance-PM.x(W) 0-+5 Maximum Power Voltage-VMw(V) 31.4 31.7 31.8 32.2 32.5 32.6 32.9 33.1 33.3 DIMENSIONS OF PV MODULE(mm/inches) Maximum Power Current-kw(A) 8.76 8.84 8.97 9.01 9.08 9.19 9.28 9.37 9.46 942/323 Open Circuit Voltage-Voc(V) 38.4 38.4 38.5 38.9 39.6 39.8 40.0 40.2 40.5 e Short Circuit Current-Isc(A) 9.24 9.42 9.51 9.66 9.68 9.77 9.85 9.94 10.0 Junction So. - s Module Efficiency n°,(%) 16.8 17,1 17.4 17.7 18.0 18.3 18.6 18.9 19.2 ' Ytl 5TC Irradiance 1000W/rn,Cell Temperature 25°C,Air Mass AM1.5. Name°4,e 'Measuring tolerance:±3%. I W ELECTRICAL DATA(NOCT) n Maximum Power-Pow(Wp) 205 209 212 216 220 223 227 231 235 t-2 I i Maximum Power Voltage-VMPP(V) 29.1 29.4 29,5 29.9 30.1 30.2 30.5 30.7 30.9 e® Maximum Power Current-lore(A) 7.04 7.10 7.21 7.24 7.30 7.38 7.46 7.53 7.60 Fit 9414 In°a°"A""` Open Circuit Voltage-Voc(V) 35.7 35.7 35.8 36,2 36.8 37.0 37.2 37.4 37.6 .43 Grounding Hole Short Circuit Current-Isc(A) 7.46 7.61 7.68 7.80 7.82 7.89 7.95 8.03 8.10 QAa'n He NOCT:Irradiance at 800W/rn,Ambient Temp erature 20°C.Wind Speed lm/s. MECHANICAL DATA _ 35/1.38 992/39.1 Back View Solar Cells Monocrystalline 156.75.156.75 mm(6 inches) Cell Orientation 60 cells(6 0 10) 11/0.43 SiikonSealant Module Dimensions 1650.992.35 mm(65.0 x 39.1 x 1.38 inches) Laminate loll,,, Weight 18.6 kg(41.0 Ib) • PI Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass Backsheet White[DD05A.08(II)]; rrune Black[DD05A.05(II)) 35/1.38 Frame Black Anodized Aluminium Alloy[DDO5A.08(ll),DD05A.05(I1)] (A-A) J-Box IP 67 or IP 66 rated Cables Photovoltaic Technology Cable 4.0mmz(0.006 inches2), 1000 mm(39.4 inches) -V CURVES OF PV MODULE(305W) ,00 Connector MC4 9.0 FlreType Type1orType2 20 e so '0 -- TEMPERATURE RATINGS MAXIMUM RATINGS 3.0 NOCT(Nominal Operating Cell Temperature) 44°C(±2°C) Operational Temperature -40-+85°C 0 10 20V°IrageM 40 50 Temperature Coefficient of Pow -0,39%/°C Maximum System Voltage 1000V DC(IEC) Temperature Coefficient of Voc -0.29%/°C 1000V DC(UL) P-V CURVES OF PV MoouLE(305w) Temperature Coefficient of Inc 0.05%/°C Max Series Fuse Rating 15A(Power S285W) 350 A 300 20A(Power 2290W) sso (DO NOT connect Fuse in Combiner Box with two or more strings in F,2. parallel connection) 00 WARRANTY PACKAGING CONFIGURATIONo10 year Product Workmanship Warranty Modules per box:30 pieces 0 10 3o 30 Voltage(V) 40 So 25 year Linear Power Warranty Modules per 40'container:840 pieces (Please refer to product warranty for details) CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. T i na so I a r ©2017 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Version number:TSM_EN_2018_C www.trinasolar.com V , - solar - • • w Single Phase Inverter with HD-Wave Technology for North America W SE3000H—US/ SE3800H—US/SE5000H—US/ SE6000H—US/ SE7600H—US/SE10000H—US/SE11400H—US Z Y x F 21` Y �'.-cam-" �° �§�a � �a r �.. • � � ,,.w .�.,,..�... _, -'� ', ' swarm Y�wove 80I8P n wove ✓'a ; • :• " • •••• •••• • • • 0 ! • 9 Optimized installation with HD-Wave technology Specifically designed to work with power optimizers •• Record-breaking efficiency ar Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 • UL1741 SA certified,for CPUC Rule 21 grid compliance ▪ Extremely small — High reliability without any electrolytic capacitors 111 "' "'� — Built-in module-level monitoring i���� ,wave — Outdoor and indoor installation ▪ Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us solar - • • z Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US , SE3000H-US SE3800H-US SE5000H-US , SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 ! 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300 R 208V 5000 @ 208V Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300 e 208V 5000 @ 208V AC Output Voltage Min:Nom:Max. l - • - _ - Vac - (183-208-229) AC Output Voltage Min:Nom:Max. ✓ V ✓ ✓ ✓ ,/ ✓ Vac (211-240-264) AC Frequency(Nominal) 59.3-60-60.51t1 Hz Maximum Continuous Output Current - 16 - 24 - - - A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A @ 240V GFDI Threshold 1 A Utility Monitoring,Islanding Protection, County Confi urable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 1 17650 W Maximum DC Power @208V - 5100 - 7750 - - Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - - Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency 99 I 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional121 Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/#of Strings/ 3/4"minimum/1-3 strings/ AWG Range 3/4"minimum/1-2 strings/14-6 AWG 14-6 AWG Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 in/mm x 185 Weight with Safety Switch 22/10 I 25.1/11.4 I 26.2/11.9 38.8/17.6 lb/kg Noise <25 I <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to+140/-25 to+60131(-40°F/-40°C option)141 °F/°C Protection Rating NEMA 3R(Inverter with Safety Switch) I4 For other regional settings please contact SolarEdge support UI Revenue grade inverter P/N:SExxxxH-US000NNC2 131 For power de-rating information refer to:https://www.solaredge.cam/sites/default/files/se-temperature-derating-note-na.pdf 141.40 version P/N:SExxxxH-USo00NNU4 Erg Ro H S ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2018/VO1/ENG NAM.Subject to change without notice. • solar - • l SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 "x `�.w �t r- LLJk $ • fixx. 1 j g. 04, 1 F.. 4,4 PV power optimization at the module-level — Up to 25%more energy • Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization -- Fast installation with a single bolt Next generation maintenance with module-level monitoring • Module-level voltage shutdown for installer and firefighter safety WWW.solaredge.us USA-CANADA•GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA•THENETHERLANDS-UK-ISRAEL solar - SolarEdge Power Optimizer Module Add-On for North America A P300 / P320 / P400 / P405 • P300 P320 P400 P405 —_______ (for 60-cell modules) (for high-power (for 72&96-cell (for thin film _ ___ _ _— 60-cell modules) modules) moduk-)_ INPUT Rated Input DC Power"' 300 j 320 400 405 W Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 II Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer _ DA STANRD COMPLIANCE STANDARD D- -N-- - -- — -- — — — EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters 128x152x27.5/ 128x152x35/ 128x152x48/ Dimensions(W x L x H) 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 mm/in Weight(including cables) 760(1.7 830/1.8 1064(2.3 gr(Ib Input Connector MC4 Compatible Output Wire Type(Connector Double Insulated;MC4 Compatible Output Wire Length 0.95/3.0 I 1.2/3.9 m(ft Operating Temperature Range -40-+85/-40-+185 'C('F Protection Rating IP68/N EMA6P Relative Humidity 0-100 % "l Rated STC power of the module.Module of up to.5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER1�1 Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes ' It is not allowed to mix P405 with P300/P400/P600/P700 in one string_, ,. . CE mi __ , . . ,..),WranirVIrgaimgrfiwt,10 Ahrivir,alaz&W 01al3i4 "trZa itoati Iu,tail z•o rj 1tss1rrets.v Y`C{jitkicatfrLUtj irr-.I t ii3e('i''ruoui. -J--,Rir'.11h3Un`rWott'f'vve.'r:w,,,, _ kfirg44.0.1 trri.k4 rixi-Ui tvalzx, }t; '.WA-0r).9"01.".- 01,(614'SCh1iJ, 'Yllihti.11-71r4 t,. -.