ResCheck REScheck Software Version
, ,
Compliance Certificate
Project McNeice Project
Energy Code: 2015 IECC 201$
Location: Lake George, New York (�C-0549-
Construction Type: Single-family 226.19-1-20
Project Type: New Construction McNeice, Laura
Conditioned Floor Area: 1,640 ft2
Glazing Area 17% 12 Chestnut Ln 1650 s.f.
Climate Zone: 6 (7377 HDD) SFD wlgas FP
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
McNeice Family Frank Jelley
NY NY
518-796-5611
Compliance: Passes using UA trade-off
Compliance: 0.0%Better Than Code Maximum UA: 283 Your UA: 283
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Assembly
Perimeter R-Value .R-f fue
Ceiling 1: Flat Ceiling or Scissor Truss 912 49.0 0.0 0.026 24
Wall 1:Wood Frame, 16"o.c. 2,244 21.0 0.0 0.057 104
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 332 0.260 86
Door 1:Solid 42 0.280 12
Door 2: Glass 41 0.280 11
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 816 30.0 0.0 0.033 27
Floor 2: Slab-On-Grade:Heated 28 10.0 0.684 19
Insulation depth: 4.0'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the perm' ap 'c ion.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to ply7pvi ndatory requirements listed' the REScheck Inspection Checklist..
Frank aA �/
Name-Title \ Si nature Dat
_ 5ECEllViEn
� ` 9ft AUG 2 4 2018
Q,Jp
♦` V TOWN OF QUEENSBURY
BUILDING&CODES
Project Title: McNeice Project •• :a e: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 1 of 9
k SoftwareVersion
Inspection Checklist
rs Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section I Plans Verified `` Field Verified 4
# Pre-Inspection/Plan Review Value I Value Complies? Comments/Assumptions
& Req.11i
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate DDoes Not
[PR1]' energy code compliance for the
0,, building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ElComplies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
1(PR212 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ❑Not Observable
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
i 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 2 of 9
Section i i 1
& Re ID Foundation Inspection PlansValue Verified I FieldValuefied Complies? Comments/Assumptions
q
402.1.2 Slab edge insulation R-value. R- R- ElComplies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values.
❑ Heated ❑ Heated ['Not Observable
❑Not Applicable
402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies
[FO3]1 depth/length. El Does Not table for values.
❑Not Observable
_ ❑Not Applicable
303.2.1 A protective covering is installed ❑Complies Requirement will be met.
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a ['Not Observable
minimum of 6 in. below grade.
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[FO12)2 controls installed. ElDoes Not not applicable.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 3 of 9
1 Section ? ` Plans Verified Field Verified s f
# Framing/Rough-In Inspection] Value Value , Complies? Comments/Assumptions
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
(FR1]1 ['Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ['Does Not
with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
—
402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met.
[FR23I1 installed per manufacturer's ❑Does Not
instructions.
❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met.
1[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate 5.2.0 cfm
leakage at 75 Pa. ['Not Observable
❑Not Applicable
r-
403.2.1 Supply and return ducts in attics ❑Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where< 3 inches.Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>=3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
,403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met.
[FR17]2 above 105°F or chilled fluids ['Does Not
! below 55°F are insulated to>_R-
I 3 [Not Observable
E ❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies Requirement will be met.
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met.
[FR18]2 >_R-3. ❑Does Not
I
' ❑Not Observable
I ❑Not Applicable
/403.6 Automatic or gravity dampers are —~ ❑Complies Requirement will be met.
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
[Not Observable
ElNot Applicable
I 1 High Impact(Tier 1) i 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 4 of 9
( Section 1
Insulation Inspection Plans Verified ` Field Verified j p p
i , Value i Value Complies? Comments(Assum tions
& Req.lR z-- i --,
303.1 All installed insulation is labeled ❑Complies Requirement will be met.
[IN13]2 or the installed R-values ❑Does Not
provided.
['Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ['Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel ❑Not Observable
❑Not Applicable
303.2, Floor insulation installed per ❑Complies Requirement will be met.
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor ['Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ['Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass Li Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies Requirement will be met.
(IN4]1 manufacturer's instructions. ❑Does Not
"Not Observable
I ❑Not Applicable
Additional Comments/Assumptions:
•
1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 6 of 9
Section I Plans Verified ; Field Verified
# Final Inspection Provisions Complies? I Comments/Assumptions
& Req.1Dy }- Value Value J— y
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ❑Not Observable
402.2.E ❑Not Applicable
pplicable
303.1.1.1, Ceiling insulation installed per ElComplies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable
1- —
402.2.3 Vented attics with air permeable ElComplies Requirement will be met.
[F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[FI3]1 insulation >_R-value of the ❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[FI17)1 ach in Climate Zones 1-2, and ElDoes Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
402.4.2 Wood-burning fireplaces have ElComplies Requirement will be met.
[FI8]2 tight fitting flue dampers and ❑Does Not
outdoor air for combustion.
[Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ElComplies Requirement will be met.
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 El Does Not
<=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa. For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ElComplies Requirement will be met.
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not
I either: Rough-in test:Total
leakage measured with a ENot Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met.
[FI24]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies Requirement will be met.
[FI9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ElComplies Exception: Requirement is
[FI10]2 on heat pumps. ❑Does Not not applicable.
[Not Observable
❑Not Applicable
11 High Impact(Tier 1) L 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\Fj\Arch Design\Trevor McNeice\McNeice Project.rck Page 7 of 9
Section Plans Verified E Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Re11.I0. — -
403.5.1 Circulating service hot water ❑Complies Requirement will be met.
[FI11]2 systems have automatic or ElDoes Not
accessible manual controls.
❑Not Observable
❑Not Applicable
403.6.1 All mechanical ventilation system ElComplies Requirement will be met.
[F125J2 fans not part of tested and listed ElDoes Not
HVAC equipment meet efficacy
and air flow limits. ['Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ElComplies Requirement will be met.
[FI26]2 through one-or two-pipe heating ElDoes Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ElComplies Requirement will be met.
f[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[FI29]2 comply with IEEE 515.1 or UL ElDoes Not not applicable.
515.Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ['Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies Requirement will be met.
[F130]2 have recirculation pumps that ElDoes Not
pump water from a heated water
supply pipe back to the heated [Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units ElComplies Requirement will be met.
[F13112 tested in accordance with CSA ElDoes Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
_ three or more showers.
404.1 75%of lamps in permanent ElComplies Requirement will be met.
[FI6]1 fixtures or 75%of permanent ElDoes Not
fixtures have high efficacy lamps.
Does not apply to low-voltage Not Observable
lighting. ❑Not Applicable
1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 8 of 9
II Section
# Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions
& RegJD+i — -- — -- Value Value (404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
401.3 Compliance certificate posted. OComplies Requirement will be met.
[F►7]2 ElDoes Not
❑Not Observable
:Not Applicable
303.3 Manufacturer manuals for ❑Complies Requirement will be met.
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: McNeice Project Report date: 08/07/18
Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 9 of 9
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 0.00
Floor 30.00
Ceiling/ Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.26
Door 0.28
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments